SINAMICS S120Siemens Ltda. 2009. All rights reserved.
Date: 21.07.2009
Diagnostic
Educational-goals:
You are informed over
• Diagnostic via LEDs• Diagnostic with AOP30• Diagnostic with STARTER• Messages for Faults and Warnings• Diagnostic functions• Fault finding and testing
SINAMICS S120Siemens Ltda. 2009. All rights reserved.
Date: 21.07.2009
LEDs while the control unit is booting
SINAMICS S120Siemens Ltda. 2009. All rights reserved.
Date: 21.07.2009
LEDs after the CU has booted
SINAMICS S120Siemens Ltda. 2009. All rights reserved.
Date: 21.07.2009
LEDs other Components
Motor Module
Active Line Module
SINAMICS S120Siemens Ltda. 2009. All rights reserved.
Date: 21.07.2009
Properties of the fault buffer:• A new fault incident encompasses one or more faults and is entered in fault incident 1.• The entries are arranged in the buffer according to their time of occurrence.• If a new fault incident occurs, the fault buffer is reorganized. This history is recorded in fault
incidents 2 to 8.• If the cause of at least one fault in fault incident 1 is remedied and acknowledged, the fault buffer
is reorganized. The faults which have not been remedied remain in fault incident 1.• When 8 faults have been entered in fault incident 1 and a new fault occurs, the fault in the
parameters in index 7 is overwritten by the new fault.• r0944 is incremented each time the fault buffer changes.• A fault value (r0949) can be output for a fault. The fault value is used to diagnose the fault
accurately; please refer to the fault description for details of the meaning.• Clearing the fault buffer: POWER ON clears the entire buffer.
The fault buffer is reset as follows: p0952 = 0.
Properties of the fault buffer:• A new fault incident encompasses one or more faults and is entered in fault incident 1.• The entries are arranged in the buffer according to their time of occurrence.• If a new fault incident occurs, the fault buffer is reorganized. This history is recorded in fault
incidents 2 to 8.• If the cause of at least one fault in fault incident 1 is remedied and acknowledged, the fault buffer
is reorganized. The faults which have not been remedied remain in fault incident 1.• When 8 faults have been entered in fault incident 1 and a new fault occurs, the fault in the
parameters in index 7 is overwritten by the new fault.• r0944 is incremented each time the fault buffer changes.• A fault value (r0949) can be output for a fault. The fault value is used to diagnose the fault
accurately; please refer to the fault description for details of the meaning.• Clearing the fault buffer: POWER ON clears the entire buffer.
The fault buffer is reset as follows: p0952 = 0.
Fault Buffer
SINAMICS S120Siemens Ltda. 2009. All rights reserved.
Date: 21.07.2009
Diagnostic with fault buffer
SINAMICS S120Siemens Ltda. 2009. All rights reserved.
Date: 21.07.2009
Diagnostic with warning buffer
Properties of the warning buffer:• The entries are arranged in the buffer according to their
time of occurrence.• When 8 warnings have been entered in the warning buffer
and a new warning occurs, the warning in the parameters in index 7 is overwritten by the new warning.
• r2121 is incremented each time the warning buffer changes.
• A warning value (r2124) can be output for a warning. The warning value is used to diagnose the warning accurately; please refer to the warning description for details of the meaning.
• Clearing the warning buffer: POWER ON clears the entire buffer.
• The warning buffer is reset as follows: p2111 = 0
Properties of the warning buffer:• The entries are arranged in the buffer according to their
time of occurrence.• When 8 warnings have been entered in the warning buffer
and a new warning occurs, the warning in the parameters in index 7 is overwritten by the new warning.
• r2121 is incremented each time the warning buffer changes.
• A warning value (r2124) can be output for a warning. The warning value is used to diagnose the warning accurately; please refer to the warning description for details of the meaning.
• Clearing the warning buffer: POWER ON clears the entire buffer.
• The warning buffer is reset as follows: p2111 = 0
SINAMICS S120Siemens Ltda. 2009. All rights reserved.
Date: 21.07.2009
Configuration of warnings and faults
Fault or Alarm?The fault response ?
Acknowledge mode?
SINAMICS S120Siemens Ltda. 2009. All rights reserved.
Date: 21.07.2009
Diagnostic via parameterr0002 Drive statusr0046 missing enable signalsr0050 active CDSr0721 actual terminal value CU320 Dig. I/Or0747 status of dig. Outputs CU320r4022 status of TM31 DIr4047 status of TM31 DO
r0002 Drive statusr0046 missing enable signalsr0050 active CDSr0721 actual terminal value CU320 Dig. I/Or0747 status of dig. Outputs CU320r4022 status of TM31 DIr4047 status of TM31 DO
SINAMICS S120Siemens Ltda. 2009. All rights reserved.
Date: 21.07.2009
Diagnostics with STARTER: Current actual value, phase
SINAMICS S120Siemens Ltda. 2009. All rights reserved.
Date: 21.07.2009
Diagnostic by STARTER
Control panelControl panel
StatusStatus
SINAMICS S120Siemens Ltda. 2009. All rights reserved.
Date: 21.07.2009
Drive navigator
SINAMICS S120Siemens Ltda. 2009. All rights reserved.
Date: 21.07.2009
Diagnostics drives
C) Entire diagnostic
A) Control/status word, Status parameter, missing enables
B) Interconnections
SINAMICS S120Siemens Ltda. 2009. All rights reserved.
Date: 21.07.2009
Diagnostic by STARTER: comparisation of parameters
SINAMICS S120Siemens Ltda. 2009. All rights reserved.
Date: 21.07.2009
Function generatorOperating modes of the function generator:1. Connector output2. Current setpoint downstream of filter (current setpoint filter)3. Disturbing torque (downstream of current setpoint filter)4. Speed setpoint downstream of filter (speed setpoint filter)5. Current setpoint upstream of filter (current setpoint filter)6. Speed setpoint upstream of filter (speed setpoint filter)
parameterizable signal shapes-- Square--wave-- Staircase-- Triangular-- PRBS (pseudo random binary
signal, white noise)-- Sinusoidal
• The function generator can be used to generate different signal shapes.
• Depending on the mode setting, this setpointcan then be fed into the control system, for example as a current setpoint, disturbing torque or speed setpoint.
• The impact of superimposed control loops is automatically suppressed.
6
3 42 5
SINAMICS S120Siemens Ltda. 2009. All rights reserved.
Date: 21.07.2009
Trace Functions
The trace function can be used to record measured values over a defined period depending on trigger conditions.
Trigger signals
Trigger start Trace recorder
Diagram types:• Time diagram• FFT-Diagram• Bode diagram
Recording duration
Trigger definition
Trace 1 with 4 signalsTrace 2 with 4 signalsà 2 Triggers (differently or resembles)
SINAMICS S120Siemens Ltda. 2009. All rights reserved.
Date: 21.07.2009
Measuring functions• Current controller setpoint change (behind the current setpoint filter)• Current controller reference frequency response (behind the current setpoint filter)• Speed controller setpoint change (behind the speed setpoint filter)• Speed controller disturbance step change (fault behind the current setpoint filter)• Speed controller reference frequency response (behind the speed setpoint filter)• Speed controller reference frequency response (upstream of the speed setpoint filter)• Speed controller interference frequency response (fault behind the current setpoint
filter)• Speed-controlled system (excitation downstream of current setpoint filter)
• Optimization of a drive with prepared suppression of the overlaid rule-circles.
• Very clearly programmable. • Already prepares
• Function-generator • Trace channel
Speed controller setpoint change
Speed controller reference frequency response