1
We make it possible Positive Pressure System LG 300 Lab Guard TECHNICAL SPECIFICATION Dimensions 470 mm 590 mm 800 mm specifications subject to change without notice Ordering information Lab Guard LG 300 100 120 Volts 60 Hz order code FX 2045 Lab Guard LG 300 220 240 Volts 50 Hz order code FX 2046 Spare Filter Set order code FX 2047 Return Blower order code Fx 2048 Blower-German make : Backward impeller type Pre Filter : Synthetic PU washable Hepa Filter : Efficiency 99.97% @ 0.3 microns VOC Filter: : Unique blend of activated carbon and alumina Unit capacity: : 350 CFM Mounting: : To be done outside VF Lab on any Wall Power consumption: : 90 Watts maximum Filter replacement as per auto indication Electrical supply : 100/110 volts OR 220/240 volts 50/60 Hz Distributor C Q Traceability calibration in accordance with national and international standards, NIST USA Individual and expressive quality control certificate www.shivaniscientific.com For more details go to Shivani Scientific Industries (P) Ltd + 91 22 2845 6768 + 91 22 2845 6769 + 91 22 2845 6770 + 91 22 2845 7140 + 91 22 2845 6766 Tel - Fax - e-mail [email protected] [email protected] 26A Raju Industrial Estate, Penkar Pada Road Near Dahisar Check Naka, Mira-401104 Dist. Thane (Mumbai) Maharashtra, INDIA Positive Pressure System Lab Guard The LAB+GUARD is developed to improve the laboratory air quality making it nearly equal to clean air. Thus replenishing and subsequently nourishing the entire laboratory, making it safe for the sensitive procedures to be executed. This is achieved by a number of inclusions and their applications all of which are simple, cost effective and user friendly. The positive pressure system uses the basic principle of “Over Pressure or positive pressure in a room which restricts the entry of outside air”. This is achieved by absorbing the circulating air outside the IVF Lab (Room) and then subsequently passing the same through a series of 4 stage filters thus making it quite IVF friendly. Thus ultimately the effective, circulating air in the IVF lab reaches a near clean air status, provides a positive pressure, reduces the CFU count, eliminates the SPM, VOCs and CACs. The LAB+GUARD has been designed with State of the Art technology using 4 stage filtration system. The unique filter combination filters out air and gas contaminant thus by giving most suitable air for gametes and embryos. LAB+GUARD system contains a unique 4 stage filtration system containing Prefilter, Hepa Filter and unique blend of activated carbon and alumina, which ensures wide variety of Gases, particular contaminants are oxidized or are absorbed. The LAB+GUARD has been designed to reduce the microbial air flora to the minimum level. CONCEPT DESIGN Every care has been taken in designing to make sure that air absorbed is thoroughly cleaned for contaminants and to reduce bacterial count in IVF Lab. The LAB+GUARD design also facilitates introduction of fresh air into the air circuit which gives maximum safety from Carbon dioxide released into the IVF Lab by CO2 Incubators and also it protects embryologists from gas mixtures released on work stations. OPERATING SECURITY Positive Pressure System LG 300 Lab Guard The unique design and the concept of LAB+GUARD positive pressure system not only reduces VOC content in the air but also the CFU count in the IVF Lab. The LAB+GUARD not only protects embryos and gammas but also protects embryologists who is the most affected otherwise. REDUCES CFU, REDUCES VOC In any HVAC/air flow design it is essential that net flow is going out of the room. This means room air volume and pressure should be slightly higher than adjoining areas/rooms. This will keep out any toxic fumes trying to come in. IVF labs which are not having adequate positive pressure are suceptible to risk of contamination. ENSURE NET FLOW OUT The LAB+GUARD has automatic indication for Filter change and the design facilitate extremely easy replacement of filters even by non technical staff. Other than filter change it is virtually maintenance free. MAINTENANCE If your lab does not have regulated fresh air intake or positive pressure design, there are every chances that your embryologists are breathing out CO2 tanks emptied ever year. Since CO2 can not be absorbed or filtered by Indoor air purifiers or filters. The LAB+GUARD facilitates introduction of fresh air and reduces the risk of high CO2 concentration into the IVF Lab. WHO BREATHS CO2 IN YOUR IVF LAB ? The LAB+GUARD also houses a unique automatic indication system whereby the user is informed when to change the filters, and not “every quarterly”. This feature not only gives tremendous relief to the user for tracking the stipulated time of change but also saves lot of money. CHANGE FILTERS AS PER USAGE The LAB+GUARD team helps you in evaluation of possibilities to improve air quality in your lab. If you are upgrading, expanding or setting up new lab contact us for technical assistance. UPGRADING, EXPANDING OR SETTING UP NEW IVF LAB? RETURN BLOWER The return blower is utilised to circulate back the air of IVF lab to room where LAB+GUARD has been fitted. Split A/C LAB GUARD LAB GUARD Return Blower Fresh Air IVF LAB UTILITY ROOM

setup ivf lab in Africa,setup your ivf lab in India,worldwide ivf clinics

Embed Size (px)

DESCRIPTION

Shivani Scientific Industries (P) Ltd has vast experience of more than 20 years of designing and building pharmaceutical Laboratories as per WHO-GMP norms with stringent requirement of sterility. The same experience has helped us to fulfill the demanding needs of to-days IVF Labs. A new Lab means start contacting designers, architects, sellers, resellers, vendors, suppliers, agents, distributors to initiate slow, long and laborious process of discussing dates and negotiating rates. This, you will agree, will further eat into your most precious commodity "Time". 3D Lab design / 3 D Walk through We offer State of the Art computer modeling to visualize your Lab either in 3D or 3D Walk through, even before your lab is ready. Customised Video Processing All modern equipments comes with all provision of image processing which is very well utilized by our Combination of hardware camera selection and software selection. Multiple Camera inputs can be synthesised in one system to have better recording and processing. Embryology Services We provide assistance in providing complete embryology services from Ovum Pick-up to embryo transfer. Qualified and experienced team of clinicians and embryologists are selected to provide these services. Air Quality evaluation and improvement We have capability to thoroughly evaluate Air quality on existing Lab and recommend appropriate steps to improve the same. It varies from HVAC inspection to microbial air sampling. Hands on training for Lab Staff We offers comprehensive hands on training in collaboration with Maharashtra Animal & Fishery Sciences University to Lab Staff. Annual Maintenance of IVF Lab Equipments We undertake Annual Maintenance Contracts for IVF Labs with the support of its highly qualified team of Engineers. We also cater to calibration contracts with our highly accurate calibration equipments. Alternatively you have the easier and simpler option: Contact US for:: OUR PRODUCT RAGE IS::: IVF PRODUCTS WE MAKE: Spermfuge,Mobile Nest,Lab Guard,Warming Blocks,Ivf lab Turnkey Projects,Rapid Recovery System IVF Division:::WE SUPPLY Spermfuge,ThermoPlate,Embryo Freezer,System for ART,Suction Pumps for oocyte aspiration, CO2 incubator,warming block,micromanipulator,Microscope,Micropipettes,Clean Air System, FertAid,Embryology Academy of research Training. Autoclaves & Sterilisers:::WE MAKE Double Wall,Autoclave,Laboratory Autoclaves,Semi Automatic,Portable Autoclave, Semi Automatic,Gas cum Electric,Autoclave Horizontal Sterilizer, Fully Automatic Autoclaves GMP Compliant Series,Acculeak Detector

Citation preview

Page 1: setup ivf lab in Africa,setup your ivf lab in India,worldwide ivf clinics

We make it possible

Positive Pressure System

LG 300

Lab Guard

TECHNICAL SPECIFICATION

Dimensions

470 mm590 mm

80

0 m

m

specifications subject to change without notice

Ordering information

Lab Guard LG 300 100 120 Volts 60 Hz order code FX 2045Lab Guard LG 300 220 240 Volts 50 Hz order code FX 2046Spare Filter Set order code FX 2047Return Blower order code Fx 2048

Blower-German make : Backward impeller type Pre Filter : Synthetic PU washableHepa Filter : Efficiency 99.97% @ 0.3 micronsVOC Filter: : Unique blend of activated carbon and aluminaUnit capacity: : 350 CFMMounting: : To be done outside VF Lab on any WallPower consumption: : 90 Watts maximumFilter replacement as per auto indicationElectrical supply : 100/110 volts OR 220/240 volts 50/60 Hz

Distributor

C

Q

Traceability calibration in accordance with national and international standards, NIST USA

Individual and expressive quality control certificate

www.shivaniscientific.comFor more details go to

Shivani Scientific Industries (P) Ltd+ 91 22 2845 6768+ 91 22 2845 6769+ 91 22 2845 6770+ 91 22 2845 7140+ 91 22 2845 6766

Tel -

Fax -e-mail [email protected] [email protected]

26A Raju Industrial Estate, Penkar Pada RoadNear Dahisar Check Naka, Mira-401104Dist. Thane (Mumbai) Maharashtra, INDIA

Positive Pressure SystemLab Guard

The LAB+GUARD is developed to improve the laboratory air quality making it nearly equal to clean air. Thus replenishing and subsequently nourishing the entire laboratory, making it safe for the sensitive procedures to be executed. This is achieved by a number of inclusions and their applications all of which are simple, cost effective and user friendly.The positive pressure system uses the basic principle of “Over Pressure or positive pressure in a room which restricts the entry of outside air”. This is achieved by absorbing the circulating air outside the IVF Lab (Room) and then subsequently passing the same through a series of 4 stage filters thus making it quite IVF friendly. Thus ultimately the effective, circulating air in the IVF lab reaches a near clean air status, provides a positive pressure, reduces the CFU count, eliminates the SPM, VOCs and CACs.

The LAB+GUARD has been designed with State of the Art technology using 4 stage filtration system. The unique filter combination filters outair and gas contaminant thus by giving most suitable air for gametes and embryos.LAB+GUARD system contains a unique 4 stage filtration system containing Prefilter, Hepa Filter and unique blend of activated carbon and alumina, which ensures wide variety of Gases, particular contaminants are oxidized or are absorbed. The LAB+GUARD has been designed to reduce the microbial air flora to the minimum level.

CONCEPT

DESIGN

Every care has been taken in designing to make sure that air absorbed is thoroughly cleanedfor contaminants and to reduce bacterial count in IVF Lab. The LAB+GUARD design also facilitates introduction of fresh air into the air circuit which gives maximum safety from Carbon dioxide released into the IVF Lab by CO2 Incubators and also it protects embryologists from gas mixtures released on work stations.

OPERATING SECURITY

Positive Pressure System

LG 300

Lab Guard

The unique design and the concept of LAB+GUARD positive pressure system not only reduces VOC content in the air but also the CFU count in the IVF Lab. The LAB+GUARD notonly protects embryos and gammas but also protects embryologists who is the most affected otherwise.

REDUCES CFU, REDUCES VOC

In any HVAC/air flow design it is essential that net flow is going out of the room. This means room air volume and pressure should be slightly higher than adjoining areas/rooms. This will keep outany toxic fumes trying to come in. IVF labs which are not having adequate positive pressure are suceptible to risk of contamination.

ENSURE NET FLOW OUT

The LAB+GUARD has automatic indication for Filter change and the design facilitate extremely easy replacement of filters even by non technical staff. Other than filter change it is virtually maintenance free.

MAINTENANCE

If your lab does not have regulated fresh air intake or

positive pressure design, there are every chances

that your embryologists are breathing out CO2 tanks

emptied ever year. Since CO2 can not be absorbed

or filtered by Indoor air purifiers or filters. The

LAB+GUARD facilitates introduction of fresh air and

reduces the risk of high CO2 concentration into the

IVF Lab.

WHO BREATHS CO2 IN YOUR IVF LAB ?

The LAB+GUARD also houses a unique automatic indication system whereby the user is informed when to change the filters, and not “every quarterly”. This feature not only gives tremendous relief to the user for tracking the stipulated time of change but also saves lot of money.

CHANGE FILTERS AS PER USAGE

The LAB+GUARD team helps you in evaluation of possibilities to improve air quality in your lab. Ifyou are upgrading, expanding or setting up new lab contact us for technical assistance.

UPGRADING, EXPANDING ORSETTING UP NEW IVF LAB?

RETURN BLOWERThe return blower is utilised to circulate back the air of IVF lab to room where LAB+GUARD hasbeen fitted.

Sp

lit A

/C

LA

B G

UA

RD

LA

B G

UA

RD

Ret

urn

Blo

wer

Fresh Air

IVF LAB UTILITYROOM