UNIVERSAL DIGITAL REPEATER UDR-6 · OPERATION MANUAL
3
CONTENTS1. Application...........................................................................................................22. Options..................................................................................................................23. Equipmentsupplied..........................................................................................34. Specifications.....................................................................................................45. Operationandfunctions................................................................................5 5.1.Gyrocompassoperationmode(GYRO)........................................5 5.2. Logoperationmode(LOG)..................................................................8 5.3.Dual-axislogoperationmode(LOG2)........................................13 5.4.Windsensoroperationmode(WIND)........................................15 5.5. Echosounderoperationmode(DEPT).......................................18 5.6.Мasterclocksystemoperationmode(TIME).........................206. Preparationtouse........................................................................................22 6.1.Unitinstallation.....................................................................................22 6.2.Powerconnection................................................................................22 6.3.Connectiontodatainputs/outputs.............................................23 6.4.Repeateradjustment.........................................................................247. Safetyprecautions........................................................................................318. Maintenance....................................................................................................329. Transportationandstorage......................................................................3210. Warranty..........................................................................................................3311. Purchaseinformation..................................................................................3512. Approvalcertificate......................................................................................3613. Commissioningreport.................................................................................37
UNICONT · 2008
4
1. ApplicationUniversalDigitalRepeaterUDR-6(x)isdesignedtodisplayingtheinformationreceivedfrommarineequipmentintheNMEAformat(IEC61162-1Ed.2Mar.equip.Part1-Digitalinterfaces,inthefollowingIEC61162).UDR-6(x)suppliesindifferentTypesandVersions.TheTypeofrepeatermeansfunctionality.TheVersiondependsonmethodofmounting.
2. OptionsDifferenttypesofrepeaterareabletodisplaythedifferentinformationfromvariousmarinedevices,suchas:
gyrocompass(typesUDR-6GandUDR-6U);–speedlog(typesUDR-6L,UDR-6U);–dual-axisspeedlog(typesUDR-6L,UDR-6U);–windsensor(typesUDR-6W,UDR-6U);–echo-sounder(typesUDR-6E,UDR-6U);–masterclocksystem(typesUDR-6С,UDR-6U).–
UnifiedversionofrepeaterUDR-6Ucanindicatethedatafromanydevicepointedabove.
UNIVERSAL DIGITAL REPEATER UDR-6 · OPERATION MANUAL
5
NOTE: Therearetwodifferentversionsofmountingtheunit.Iftheunitsuppliedwithspecialbulkhead-mountedmetalcase,thenthatismarkedasUDR-6(x)-blk.Theflat-mountedversionismarkedasUDR-6(x)-fl.Theoneshouldpointthat,whenmakeupthequery.Inthefollowingtextblkandflindexneglected,exceptthespecialtasks.
3. Equipment supplied
Item Quantity
1.DigitalrepeaterUDR-6(х) 1
2.Caselatches* 2
3.Technicaldocumentation 1
4.Fuse3A 1
Hereandbelow,(x)–meanstheTypeofrepeater:
U –UNIFIED,
G –GYRO,L –LOGandDUALAXISLOG,W –WINDSENSOR,
UNICONT · 2008
6
E –ECHO-SOUNDER,
C –MASTERCLOCKSYSTEM.
*-Thetypeoflatchesdependsonthewayofinstallation(seetheNOTEabove).
4. SpecificationsPowervoltage 24VDC±10%
Powerconsumption 3W
Galvanicisolation Yes
Operatingtemperature -15..+40°C
Storagetemperature -20..+45°C
Dimension[WxHxD] 144x144x120mm(158x186x109,5mm)*
Panelcut-out 135,8x135,8mm
Moistureprotection IP54
Weight 0.5kg
Safedistancetomagneticcompass 1m
Softwareversion 2.5
*–forUDR-6(x)-blk
UNIVERSAL DIGITAL REPEATER UDR-6 · OPERATION MANUAL
7
5. Operation and functions
5.1. Gyro compass operation mode (GYRO). For UDR-6G and UDR-6U types only.TheGYROoperationmodeisintendedfordisplayingactualvesselheading(HDT),headingdeviationandvariation(HDG),headingobtainedbytheownshipdata(OSD)signal,rateofturnanddirectionofturn(ROT).InparenthesistheNMEAsentencesarespecifiedcorrespondingwithindex,displayinginthealphabeticfieldsofrepeater.
5.1.1. HDTfunction($--HDT,field0,T*cs<CR><LF>).Actualvesselheading,producedbyanydeviceorsystemproducingtrueheading.
5.1.1.1. Intheuppernumericalfield,theactualheadingisdisplayed(HDTintheupperalphabeticfield)indegrees(°)
5.1.1.2. Therateofturnisdisplayed(ROT)inthelowernumericalfield.Theunitsaredegreesperminute(°/min).Additionally,leftwardorrightwardarrowsarehighlighted,dependingondirectionofturnindication.
UNICONT · 2008
8
Field Indication Units Additional indication NotesUpperalphabetic HDTUppernumerical Actualheading °Loweralphabetic ROT
LowernumericalRateofturn °/
minDirectionofturnarrowindicator
5.1.2. HDGfunction($--HDG,field0,field1,field2,field3,field4*hh<CR><LF>).Heading,deviationandvariation.Heading(magneticsensorreading),whichifcorrectedfordeviationwillproducemagneticheading,whichifoffsetbyvariationwillprovidetrueheading.
5.1.2.1. Bydefault,intheuppernumericalfieldthemagneticheadingindegrees(°)isdisplayed(HDMintheupperalphabeticfield).BypressingF1key,theactualheadingisswitchedto(HDTintheupperalphabeticfield).ThemagneticheadingindicationisreturnedtobyagainpressingF1key.
5.1.2.2. Therateofturnisdisplayed(ROT)inthelowernumericalfield.Theunitsaredegreesperminute(°/min).Additionally,leftwardorrightwardarrowsarehighlighted,dependingondirectionofturnindication.
UNIVERSAL DIGITAL REPEATER UDR-6 · OPERATION MANUAL
9
Field Indication Units Additional indi-cation Notes
Upperalphabetic HDM,(HDT) SwitchablewithF1key
Uppernumerical Magneticheading(actualheading) °
Loweralphabetic ROT
Lowernumerical Rateofturn °/min
Directionofturnarrowindicator
5.1.3. OSDfunction($--OSD,field0,field1,field2,field3,field4,field5,field6,field7,field8*hh<CR><LF>).Ownshipdata(OSD)givesthemovementvectoroftheshipbasedonthesensorsandparametersinuse.Heading,course,speed,setanddriftsummary.Usefulfor,butnotlimitedtoradar/ARPAapplications.
5.1.3.1. TheactualheadinggivenbyOSD-commanddisplayedintheuppernumericalfield.Theunitsaredegrees(°).
5.1.3.2. Inthelowernumericalfield,rateofturnisdisplayed(ROT).Theunitsaredegreesperminute(°/min).Additionally,leftwardorrightwardarrowsarehighlighted,dependingondirectionofturnindication.
UNICONT · 2008
10
Field Indication Units Additional NotesUpperalphabetic OSD
Uppernumerical Actualheading °Loweralphabetic ROT
Lowernumerical Rateofturn °/min. Directionofturnarrowindicator
5.2. Log operation mode (LOG).For UDR-6L and UDR-6U types only.TheLOGoperationmodeisspeedtrackingmode,thatintendedfordisplayingofthewater-referencedspeed(VHW),courseovergroundandground-referencedspeed(VTG),distancetravelledthroughthewater(VLW),speedobtainedbytheownshipdata(OSD)signal.InparenthesistheNMEAsentencesarespecifiedcorrespondingwithindex,displayinginthealphabeticfieldsofrepeater.
5.2.1. VHWfunction($--VHW,field0,field1,field2,field3,field4,field5,field6,field7*cs<CR><LF>).Thecompassheadingtowhichthevesselpointsandthespeedofthevesselrelativetothewater.
5.2.1.1. Intheuppernumericalfieldthewater-referencedspeedgivenbyVHW-commandisdisplayed.Ifthespeedispositive,
UNIVERSAL DIGITAL REPEATER UDR-6 · OPERATION MANUAL
11
upwardarrowishighlighted,otherwisethedownwardarrowis.Theunitsareknots(kn).BypressingF1key,km/h(kmperhour)unitsareselected.TheknotunitsarereturnedtobyagainpressingF1key.
5.2.1.1. Inthelowernumericalfieldcumulativedistance,givenbyVLW-commandisdisplayed.Theunitsarenauticalmiles(nm).Withthisfunction,intheloweralphabeticfieldTOTLisdisplayed.PressingF2keywillswitchthisfunctiontodisplaythemileageofthecurrenttrip(distancesinceresetinnauticalmiles).Inthiscase,intheloweralphabeticalfieldTRIPisdisplayed.TotalcumulativedistanceisreturnedtobyagainpressingF2key.
Field Indication Units Additional indi-cation Notes
Upperal-phabetic VHW
Uppernu-merical Speed knor
km/hDirectionofspeedarrowindicator
SwitchablewithF1key
Loweral-phabetic TOTL/TRIP Switchable
withF2keyLowernu-merical
Distancetravelledthroughthewater nm
UNICONT · 2008
12
5.2.2. VTGfunction($--VTG,field0,field1,field2,field3,field4,field5,field6,field7,field8*hh<CR><LF>).Theactualspeedrelativetotheground.
5.2.2.1. Intheuppernumericalfield,theactualspeedrelativespeedgivenbyVTGcommandisdisplayed(VTGintheupperalphabeticfield).Theunitsareknots(kn).Ifthespeedispositive,upwardarrowishighlighted,otherwisethedownwardarrowis.BypressingF1key,km/h(kmperhour)unitsareselected.TheknotunitsarereturnedtobyagainpressingF1key.
5.2.2.2. Inthelowernumericalfieldcumulativedistance,givenbyVLW-commandisdisplayed.Theunitsarenauticalmiles(nm).Withthisfunction,intheloweralphabeticfieldTOTLisdisplayed.PressingF2keywillswitchthisfunctiontodisplaythemileageofthecurrenttrip(distancesinceresetinnauticalmiles).Inthiscase,intheloweralphabeticalfieldTRIPisdisplayed.TotalcumulativedistanceisreturnedtobyagainpressingF2key.
UNIVERSAL DIGITAL REPEATER UDR-6 · OPERATION MANUAL
13
Field Indication Units Additional in-dication Notes
Upperalpha-betic VTG
Uppernu-merical Actualspeed knor
km/h
Directionofspeedarrowindicator
SwitchablewithF1key
Loweralpha-betic TOTL/TRIP Switchable
withF2key
Lowernu-merical
Distancetrav-elledthroughthewater
nm
5.2.3. OSDfunction($--OSD,field0,field1,field2,field3,field4,field5,field6,field7,field8*hh<CR><LF>).AspointedinError!Referencesourcenotfound.,ownshipdata(OSD)signalisabletoprovidetheactualspeedship’sdata.
5.2.3.1. IntheuppernumericalfieldtheactualspeedgivenbyOSD-commandisdisplayed.Theunitsareknots(kn).SelecttheotherunitsbypressingF1key:kmh(kmperhour),mlh(milesperhour).Ifthespeedispositive,upwardarrowishighlighted,otherwisethedownwardarrowis.
UNICONT · 2008
14
5.2.3.2. Inthelowernumericalfieldcumulativedistance,givenbyVLW-commandisdisplayed.Theunitsarenauticalmiles(nm).Withthisfunction,intheloweralphabeticfieldTOTLisdisplayed.PressingF2keywillswitchthisfunctiontodisplaythemileageofthecurrenttrip(distancesinceresetinnauticalmiles).Inthiscase,intheloweralphabeticalfieldTRIPisdisplayed.TotalcumulativedistanceisreturnedtobyagainpressingF2key.
Field Indication Units Additional in-dication Notes
Upperalphabetic OSD
Uppernumerical Actualspeed kn,kmh,
mlh
Directionofspeedarrowindicator
SwitchablewithF1key
Loweralphabetic TOTL/TRIP Switchable
withF2key
Lowernumerical
Distancetrav-elledthroughthewater
nm
UNIVERSAL DIGITAL REPEATER UDR-6 · OPERATION MANUAL
15
5.3. Dual-axis log operation mode (LOG2).TheLOG2operationmodeisdual-axisspeedtrackingmode(VBW).InparenthesistheNMEAsentenceisspecifiedcorrespondingwithindex,displayinginthealphabeticfieldsofrepeater.
For UDR-6L and UDR-6U types only.5.3.1. VBWfunction($--VBW,field0,field1,field2,field3,field4,
field5,field6,field7,field8,field9*hh<CR><LF>).Water-referencedandground-referencedspeeddata.
5.3.1.1. Intheuppernumericalfield,thelongitudinalwater-referencedspeed(WTL)isdisplayed.Theunitsareknots(kn).Additionally,upwardarrowishighlightedifthespeedispositiveanddownwardarrowifitisnegative.
5.3.1.2. Inthelowernumericalfield,thetransversalwater-referencedspeed(WTT)isdisplayed.Theunitsareknots(kn).Additionally,leftwardorrightwardarrowsaredisplayeddependingonshipdriftdirection.Ifdataintheupperandlowernumericalfieldsarenon-reliable,dots(……)aredisplayed,anddirectionarrowsaredim.
5.3.1.3. BypressingF1key,thelongitudinalground-referencedspeed(BTL)isswitchedto.Intheuppernumericalfield,thebottomspeedlongitudinalcomponentisdisplayed.Theunits
UNICONT · 2008
16
areknots(kn).Additionally,upwardarrowishighlightedifthespeedispositiveanddownwardarrowifitisnegative.
5.3.1.4. Inthelowernumericalfield,thetransversalground-referencedspeedcomponent(BTT)isdisplayed.Theunitsareknots(kn).Additionally,leftwardorrightwardarrowsaredisplayeddependingonshipdriftdirection.Ifdataintheupperandlowernumericalfieldsarenon-reliable,dots(……)aredisplayed,anddirectionarrowsaredim.Thewater-referencedspeedmodeisreturnedtobyagainpressingF1key.
Field Indication Units Additional indication Notes
Upperalpha-betic WTL(BTL)
Thewater/ground-referencedspeedmodeswitchingbypressingF1key
Uppernumerical Longitudinalspeed Kn Directionofspeedar-
rowindicatorLoweralpha-betic WTT(BTT)
Lowernumerical Transversalspeed Kn Directionofspeedar-
rowindicator
UNIVERSAL DIGITAL REPEATER UDR-6 · OPERATION MANUAL
17
5.4. Wind sensor operation mode (WIND).TheWINDoperationmodeisthewindtrackingmode,whichintendedfordisplayingofthewinddirectionandspeed(MHW)orwindspeedandangle(VTG).InparenthesistheNMEAsentencesarespecified.
For UDR-6W and UDR-6U types only.5.4.1. MWDfunction($--MWD,field0,field1,field2,field3,field4,
field5,field6,field7*hh<CR><LF>).Thedirectionfromwhichthewindblowsacrosstheearth’ssurface,withrespecttonorth,andthespeedofthewind.
5.4.1.1. Intheuppernumericalfield,thetruewinddirectionisdisplayed.Theunitsaredegrees(°).Withthisfunction,intheupperalphabeticfieldDIRisdisplayed.
5.4.1.2. BypressingF1key,thewindmagneticdirectionisswitchedto.Theunitsaredegrees(°).Withthisfunction,intheupperalphabeticfieldMDIRisdisplayed.
5.4.1.3. Inthelowernumericalfield,thewindspeedisdisplayed.Theunitsareknots(kn)ormeterpersecond(m/s).TheunitsareswitchedbypressingF2key.Withthisfunction,intheloweralphabeticfield,SPEDisdisplayed.
UNICONT · 2008
18
Field Indication Units Additional indication Notes
Upperalphabetic DIR,MDIRDIRandMDIRareselectedbypressingF1key.
Uppernumerical Direction ° Loweralphabetic SPED
Lowernumerical Windspeed Kn,m/s
TheunitsareswitchedbypressingF2key.
5.4.2. MWVfunction($--MWV,field0,field1,field2,field3,field4*hh<CR><LF>).Windspeedandangle.WhenthereferencefieldissettoR(Relative),dataisprovidedgivingthewindangleinrelationtothevessel’sbow/centrelineandthewindspeed,bothrelativetothe(moving)vessel.Alsocalledapparentwind,thisisthewindspeedasfeltwhenstandingonthe(moving)ship.WhenthereferencefieldissettoT(Theoretical,calculatedactualwind),dataisprovidedgivingthewindangleinrelationtothevessel’sbow/centrelineandthewindspeedasifthevesselwasstationary.Onamovingshipthesedatacanbecalculatedbycombiningthemeasuredrelativewindwiththevessel’sownspeed.
UNIVERSAL DIGITAL REPEATER UDR-6 · OPERATION MANUAL
19
5.4.2.1. Intheuppernumericalfield,windangleisdisplayed.Theunitsaredegrees(°).Withthisfunction,intheloweralphabeticfield,DIRisdisplayed.Ifdatafromthewindsensorareconsideredunreliable,inthenumericalfieldthedots(“……”)aredisplayed.
5.4.2.2. Inthelowernumericalfield,thewindspeedvalueisdisplayed,whileintheloweralphabeticfiledSPEDisdisplayed.Threekindsofunitsarepossible:knots(kn),meterpersecond(m/s),kmperhour(kmh).Theunitsareselectedautomaticallyaccordingtoinformationreceivedfromthewindsensor.Ifthedatalookunreliable,inthenumericalfieldthedots(“……”)aredisplayed.
Field Indication Units Additional indication Notes
Upperalphabetic DIR
Uppernumerical Angle °
Loweralphabetic SPED
Lowernumerical Windspeed Kn,m/s,kmh
UNICONT · 2008
20
5.5. Echo sounder operation mode (DEPT).TheDEPToperationmodeisthedepthtrackingmode,whichintendedfordisplayingofthedepthbelowtransducer(DBT)orsimpledepth(DPT).InparenthesistheNMEAsentencesarespecifiedcorrespondingwithindex,displayinginthealphabeticfieldsofrepeater.
For UDR-6E and UDR-6U types only.5.5.1. DBTfunction($--DBT,field0,field1,field2,field3,field4,
field5*hh<CR><LF>).Waterdepthreferencedtothetransducer.
5.5.1.1. Intheuppernumericalfield,thedepthisdisplayed(DBTintheupperalphabeticfield).Threekindsoftheunitsarepossible:feet(ft),meters(m),fathoms(fm).TheunitsareswitchedbysequentialpressingF1key.
Field Indica-tion Units Additional
indication Notes
Upperalphabetic DBT
Uppernumerical Depth ft,m,fm
TheunitsareswitchedbypressingF1key.
LoweralphabeticLowernumerical
UNIVERSAL DIGITAL REPEATER UDR-6 · OPERATION MANUAL
21
5.5.2. DPT function($--DPT,field0,field1,field2*hh<CR><LF>).Waterdepthrelativetothetransducerandoffsetofthemeasuringtransducer.Positiveoffsetnumbersprovidethedistancefromthetransducertothewaterline.Negativeoffsetnumbersprovidethedistancefromthetransducertothepartofthekeelofinterest.
5.5.2.1. Intheuppernumericalfield,thedepthisdisplayed,DPTintheupperalphabeticfield.Theunitsaremeters(m).
Field Indication Units Additional indication Notes
Upperalphabetic DPT
Uppernumerical Depth m
Loweralphabetic
Lowernumerical
UNICONT · 2008
22
5.6. Мaster clock system operation mode (TIME). TheTIMEoperationmodeisintendedfordisplayingoftheUTC,day,month,yearandlocaltimezone(ZDA).InparenthesistheNMEAsentencesarespecified.
Localtimezoneisthemagnitudeofhoursplusthemagnitudeofminutesadded,withthesignoflocalzonehours,tolocaltimetoobtainUTC.LocalzoneisgenerallynegativeforEastlongitudeswithlocalexceptionsneartheInternationalDateLine.
For UDR-6C and UDR-6U types only.Timeanddateprotocol:
HH:MM:SS SP DD/MN/YY SP NNN SP WHH =hours,0…23MM =minutes,00…59
SS =seconds,always00
DD =day,01…31MM=month,01…12
YY =year00…99NNN=daynumber,001…366
W =dayofweek,1…7
UNIVERSAL DIGITAL REPEATER UDR-6 · OPERATION MANUAL
23
5.6.1. Intheuppernumericalfield,thetime(hoursandminutes)isdisplayed,TIMEintheupperalphabeticfield.
5.6.1.1. Inthelowernumericalfield,thedate(day/month/year)isdisplayed,andDATEintheloweralphabeticfield.
Field Indication Unit Additional indication Notes
Upperalphabetic TIME
Uppernumerical Time(hoursandminutes)
Loweralphabetic DATE
Lowernumerical Date:dd/mm/yy
UNICONT · 2008
24
6. Preparation to use
6.1. Unit installationSelectlocationfordisplay.Alocationoutofdirectsunlightprovidesbestvisibility.Theunitmaybemountedfromabulkheadorinstalledinaflushpanel.Panelcutoutdimensionsaregiveninthespecifications.
Overallandinstallationdimensionsofflat-mountedandbulkhead-mountedversionsaregiveninFig4andFig5respectively.
6.2. Power connectionWARNING: All electric connections with external units must be hooked-up strictly via the existing cable entries; that must be further sealed by tightening the elements of the cable glands.
Connectthepowervoltage24VDCtotheterminalJ1(fig.3).Checkthepolaritywhenwiringloadsupplyleadstoterminal.Thepowerconsumptionisnomorethan3W
UNIVERSAL DIGITAL REPEATER UDR-6 · OPERATION MANUAL
25
6.3. Connection to data inputs/outputs
6.3.1. Connection to data inputsThereareseveraldatainputsinrepeater.ThedatamightbereceivedthroughtheserialinterfaceRS–232:terminalJ2(RXD,commonGNDwire,jumperJP5intheupperposition)orthroughtheRS–422interface:terminalJ3(differentialinputsRx-andRx+,commonGNDwire,jumperJP5inthelowerposition).Oncethepowerissupplied,adjustrepeatertoreceiveappropriatesentenceformat.Theprocedureisdescribedin6.4.Ifthedatasourcedeviceoperatesnormally,repeatershalldisplaythedatareceivedaccordingto.
Checkthepolaritywhenconnectingthedatacable,otherwisethereareno-dataordata-losesituationmaytakeaplace.
6.3.2. Connection to data outputsInformationreceivedbytherepeaterpassestheamplifierandsuppliedtotwoserialinterfaceRS-422socketsJ4andJ5(differentialoutputsTx-andTx+,commonGNDwire).Thus,severalrepeaterscanbeconnectedinseriesandprovidedwithdatafromthesamedevicew/oamplifying.
UNICONT · 2008
26
6.4. Repeater adjustment
6.4.1. General settingsGeneralsettingmenuisenteredbypressingF2keyandholdingitforatleast1sec.Tochangethemodepress«+»or«–»keys.SelectedmodeisconfirmedbypressingF1key.PressF2keytoexitthemenuorfortomaketheonestepback.Thestructureofrepeater’sgeneralsettingsisshowninFig1.
COM RATE=speed(b/s):1200,2400,9600,14400,19200,28800,38400,57600,76800,115200,230400;
COM PRTY=paritybit:NONE,EVEN,ODD;
COM STOP=thenumberofstopbits:1bit,2bit;
KEYB CLCK=keypressingsound:YES,NO;
UNUS TOUT=operatorinactivitytimeafterwhichtheoptionmenuisautomaticallyleft:5sec,10sec,15sec,20sec,25sec,OFF;
SOFT VER#=softwareversion.
CSUM MODEchecksumtestofthedatareceived:ON,OFF.
DISP TOUT=maxtimetowaitforincomingsignal:1sec,2sec,5sec,10sec,15sec,20sec,25sec,OFF.
UNIVERSAL DIGITAL REPEATER UDR-6 · OPERATION MANUAL
27
WARNING: Message MISS DATA will be displayed, if:
settings of the repeater and transmitting device –(signal source) are inconsistent;signal (from a device connected) update time –threshold as set in the repeater (DISP TOUT) is exceeded;the data line is interrupted.–
6.4.2. Main settingsThemainsettingmenuisenteredbyholdingF1keyforatleast1sec.Tochangethefunctionpress«+»or«–»keys.SelectedfunctionisconfirmedbypressingF1key.PressF2keytoexitthemenuorfortomaketheonestepback.Thestructureoftherepeater'smainmenuisshowninFig2.
WARNING: If selected repeater’s function is inconsistent with the signal source, message MISS DATA will appear.
UNICONT · 2008
28
Fig 1. General settings menu
UNIVERSAL DIGITAL REPEATER UDR-6 · OPERATION MANUAL
29
Fig 2. Main menu, depending on type of repeater
UNICONT · 2008
30
Fig 3. Arrangement of terminals on printed circuit board.
UNIVERSAL DIGITAL REPEATER UDR-6 · OPERATION MANUAL
31
Fig 4. Repeater UDR-6(x)-fl installation dimensions
UNICONT · 2008
32
Fig 5. Repeater UDR-6(x)-blk installation dimensions
UNIVERSAL DIGITAL REPEATER UDR-6 · OPERATION MANUAL
33
7. Safety precautions
WARNING: Mounting, demounting and repairs of the UDR-6(x) must be performed when the power 24VDC is OFF.
Itisprohibitedto:
installthefuseswithratingsinconsistentwiththisManual;–exposetheunittoimpactsandtostretchtheconnectedcables;–connecttherepeatertonetworksdifferentfrommentionedinthe–presentManual;operatetheunitwhenitisoutoforder;–mounttheunitcloserthan1metersfromthemagneticcompass;–locatetherepeaterlessthan1mawayfromthemagnetic–compass;supplytheunitwithvoltagedifferentfrom24VDC±10%–
Don’tplacetheUnitintothewater.
Don’tuseorganicsolventstoavoidinflictingdamagetotheappliedimageswhencleaningthesurfaceoftheUnit.
UNICONT · 2008
34
8. MaintenanceInordertokeepUDR-6(x)properlyfunctioningduringoperationalperiod,routingmaintenanceshouldbeperformed.
Firstroutingmaintenanceincludesperiodical(nolessthanonceperhalf-year)visualinspectionwithdustremovalusingsofttissueandabrushandperformancemonitoringonthevisualbasis:LEDsglowing,voltageatload,switchingtothebackupmode.
SecondroutingmaintenanceshouldbeperformedwhenfaultsofUDR-6(x)aredetectedandincludesperformancecheckoftheUnitincompliancewithcorrespondingsectionsofthepresentManual.
Ifit’simpossibletofixthefaultsofUDR-6(x)onthespot,itshouldbeforwardedtorepairs.
9. Transportation and storageTransportationisperformedusingthecardboardwrapperatanyenclosedtransportfacility.
UDR-6(x)mustbestoredinenclosedspaceat–20…+45°C.
UNIVERSAL DIGITAL REPEATER UDR-6 · OPERATION MANUAL
35
10. WarrantyThemanufacturerguaranteesnormaloperationoftheUniversalDigitalRepeaterUDR-6(x)incaseofcompliancewithtransportation,storage,mountingandoperationrulesandregulations.
WarrantyperiodoftheUnitshelflifeis18monthsfromthedateofselling.
Warrantyperiodofoperationis12monthsfromthedateofcommissioningoftheUnit.Duringwarrantyperiodtheownercanclaimafreerepairorseparateblockreplacement,ifthedefectisduetomanufacturer’sfault.
Warrantyrepairsareperformedifthefollowingdocumentsarepresent:
givenOperationsManual;–Approvalcertificate;–Commissioningreport.–
ManufacturercannotbeheldliableforUnitmalfunctioningandsuspendsanywarrantyliabilitiesinthefollowingcases:
noncompliancewithrulesofmounting,operationand–transportation;applyingofthenon-standardelectricapparatus;–
UNICONT · 2008
36
anattempttoperformrepairbyanypersonwhoisnotan–authorizedrepresentativeoftheManufacturer;lossofmarketability,andcaseintegrityandforreasonsbeyondthe–controlofthemanufacturer.
Ifthecommissioningmarkisabsent,periodofwarrantyrepairsisreckonedfromthedateofsellingoftheUnit.
ShouldthepresentOperationsManualbelost,duplicatesofacceptancereportandcommissioningreportarenotissued,andtheOwnerforfeitshisrightforfreerepairduringthewarrantyperiod.
UNIVERSAL DIGITAL REPEATER UDR-6 · OPERATION MANUAL
37
11. Purchase information
Serialnumber___________________
Packingdate__________________
Supplier:UNICONT Ltd. Co.
Stamphere
UNICONT · 2008
38
12. Approval certificate
UniversalDigitalRepeaterUDR-6(x)isinaccordancewithdocumentationandisconsideredinworkingorder.
Serialnumber_________________
Delivered by:
Companyname________________________________
Fullname________________________signature______________
Accepted by:
Companyname________________________________
Fullname________________________signature______________
Acceptancedate________________________
UNIVERSAL DIGITAL REPEATER UDR-6 · OPERATION MANUAL
39
13. Commissioning report
UniversalDigitalRepeaterUDR-6(x)
Serialnumber___________________
TheUnithasbeencommissioned.
Date___________________________
Placeofinstallation:
___________________________________________________
___________________________________________________
Installedby___________________________________________
(fullname,signature)