The new alternative to cutting pipes and mechanical meters from Micronics, for simple, low cost flow measurement from outside the pipe!The U1000 is an ultrasonic permanent/fixed clamp-on flow metering solution for measuring preset flow rate – l/m with a volume pulse output in litres and with a 4-20mA flow rate signal, which can be used as a stand alone meter or as an integral part of an aM&T or BEM’s system.
Simple to install – clamp-on to the pipe, connect power and enter the pipe diameter, no specialist skills or tools required!
A cost effective alternative to traditional in-line meter installation, plus dry servicing, providing minimum downtime and maximum availability!
Compact, rugged and reliable, the U1000 has been designed to provide sustained performance in industrial environments.
For further information please visit:www.micronicsflowmeters.com
or call
+44 (0)1628 810456
u.khalil
u.khalil
La nouvelle gamme de débitmètres ultrasoniques de Micronics, pour une mesure du débit simple et à faible coût les mesures se font à l'extérieur des conduits.
u.khalil
u.khalil
Le U1000 est un ultrason permanent/fixe de mesure de débit préréglée - l / m avec une sortie impulsionnelle de volume en litres et avec une sortie 4-20mA qui peut être utilisé comme un compteur ou en tant que partie intégrante d'un système de gestion des flux d'eau.
u.khalil
u.khalil
u.khalil
u.khalil
Simple à installer -"clamp-on" sur la conduite, brancher et programmer le diamètre de la conduite sans outils spéciaux.
u.khalil
u.khalil
u.khalil
Une gamme rentable à l'installation de compteurs traditionnels en ligne, plus l'entretien à sec, fournissant un minimum de temps et une disponibilité maximale !
u.khalil
u.khalil
Compact, robuste et fiable, le U1000 a été conçu pour fournir une performance durable dans les milieux industriels.
u.khalil
u.khalil
Mesure de débit et volume liquide
u.khalil
u.khalil
Facile d’installation
u.khalil
u.khalil
Capteurs "Clamp-on"
u.khalil
u.khalil
Faible coût d'installation par rapport aux débitmètres intrusifs
u.khalil
u.khalil
u.khalil
u.khalil
u.khalil
INDUSTRIES:
n Building Services
n Energy Management
n Water Treatment
n Chemical
n Pharmaceutical
n Petrochemical
n Food
RECOMMENDED FOR:
n Hot water < 85°C
n Chilled water
n Potable water
n Demineralised water
APPLICATION/USE:
n Hot water metering and flow measurement
n Flow measurement for heat metering
n Chilled water metering and flow measurement
n Flow measurement for chilled water energy metering
n Potable water metering and flow measurement
n Process water metering and flow measurement
n Ultrapure water measurement
U1000 – Permanent Ultrasonic Liquid Flow Meter
U1000 Specification
Accuracy: +/-1-3% of flow reading for >0.3m/s
FlowVelocityRange: 0.1 to 10m/s
PipeRange: 50-150mm Nominal Bore
WaterTempRange: 0°C to 85°C
FlowRateOutput: Opto Isolated 4-20mA
VolumeOutput: Pulse or Frequency
Outputs preset to default condition based on Pipe Nominal Bore
ExternalPowerSupply:12V-24V +/- 10% AC/DC at 7 watts
ElectronicsEnclosure: IP54
Input/OutputCable: 5m x 6 core for power in and data out
u.khalil
u.khalil
Bâtiments
u.khalil
Gestion de l'énergie
u.khalil
Eau
u.khalil
Industrie chimique
u.khalil
Industrie pharmaceutique
u.khalil
Industrie pétrochimique
u.khalil
Agroalimentaire
u.khalil
u.khalil
RECOMMANDÉ POUR :
u.khalil
u.khalil
Eau chaude < 85°C
u.khalil
Eau de refroidissement
u.khalil
Eau potable
u.khalil
Eau déminéralisée
u.khalil
u.khalil
APPLICATION/ UTILISATION :
u.khalil
u.khalil
Compteurs d'eau chaude et mesure du débit
u.khalil
u.khalil
La mesure du débit pour compteurs thermique
u.khalil
u.khalil
Compteurs d'eau réfrigérée et mesure du débit
u.khalil
u.khalil
Mesure du débit pour eau réfrigéré compteurs d'énergie
u.khalil
u.khalil
Compteurs d'eau potable et mesure du débit
u.khalil
u.khalil
Compteurs d'eau et mesure du débit
u.khalil
u.khalil
Mesure d'eau ultrapure
u.khalil
u.khalil
Débitmètre ultrasonique Fixe
u.khalil
u.khalil
Caractéristiques techniques du U1000
u.khalil
u.khalil
Précision :
u.khalil
+/-1 à 3% de la lecture de flux pour vitesse > 0,3 m / s
u.khalil
u.khalil
Plage de vitesse :
u.khalil
0,1 à 10m / s
u.khalil
u.khalil
Conduite :
u.khalil
DN50 ou DN150
u.khalil
u.khalil
Température d'eau :
u.khalil
0 °C à 85 °C
u.khalil
u.khalil
Sorties :
u.khalil
4-20mA opto isolée
u.khalil
u.khalil
Sortie de volulme :
u.khalil
Impulsion ou fréquence
u.khalil
Sorties prédéfinies par défaut basé sur conduites standards.
u.khalil
u.khalil
Alimentation externe :
u.khalil
12V-24V +/- 10% AC/DC à 7 watts
u.khalil
u.khalil
Boîtier électronique :
u.khalil
IP54
u.khalil
u.khalil
Entrée / Sortie câble :
u.khalil
5m x 6 fils
v.boillot
v.boillot
Ultraflo U1000
U10004-20mA
PULSE
Sig : 87%246.3 1/min
U1000 – Permanent Ultrasonic Liquid Flow Meter
HOW DOES IT WORK?
The Ultraflo is a transit time ultrasonic flow meter designed to work with clamp-on transducers, to provide accurate measurement of liquid flowing within a closed pipe, without the need for any mechanical parts to be inserted through the pipe wall or to protrude into the flow system. It takes just a few minutes to install and there is no need to shut down flow or drain the system!
When ultrasound is transmitted between the transducers, the speed at which the sound travels through the liquid is accelerated slightly by the velocity of the liquid through the pipe. When ultrasound is transmitted in the opposite direction, the flow of the liquid causes the transmitted sound to decelerate. The subsequent time difference is directly proportional to the flow velocity in the pipe. Having measured the flow velocity and knowing the pipe cross-sectional area, the volumetric flow can be easily calculated.
Principle of Operation
U1000 Product Features and Benefits
n Factory configured for pipe size – minimal site configurationn Simplified guide rail & sensor assembly – simple installationn Clamp-on – noninvasive & low install costn LCD with backlight – install & service informationn Integral pulse and 4-20mA outputs – aM&T & BEM’s compatible
U1000 Flow Reading Screen
Simple steps for locating U1000 on pipe
1
Guide rail and sensor assembly showing grease applied
3
Connect power and sensors to electronic assembly
2
Clamp guide rail and sensor assembly to pipe and release sensor locking screws
4
Click electronic assembly onto guide rail and sensor assembly
u.khalil
u.khalil
Débitmètre Ultrasonique Fixe
u.khalil
u.khalil
Ecran de lecture
u.khalil
u.khalil
Caractéristiques et avantages du U1000
u.khalil
u.khalil
Configuré en usine pour la taille du conduit - configuration minime du site Rail de guidage simplifié et assemblage de capteur - installation simple Clamp-on - faible coût d'installation LCD avec rétro-éclairage - informations d'installation et de diagnostiques Impulsions intégré et sortie 4-20mA - compatible GTC
u.khalil
u.khalil
PRINCIPE DE FONCTIONNEMENT :
u.khalil
u.khalil
L'Ultraflo est un débitmètre ultrasonique avec mesure du temps de transit conçu pour une utilisation avec des sondes externes. Il fournit une mesure précise du débit des liquides dans une conduite sous pression, Il suffit de quelques minutes pour l'installer et il n'est pas nécéssaire de stopper le process.
u.khalil
u.khalil
Principe de fonctionnement
u.khalil
u.khalil
Lorsque l'ultrason est transmis entre les sondes, la vitesse de propagation du son au travers du liquide est légèrement accélérée par la vitesse du liquide à l'intérieur du conduit. Lorsque l'ultrason est transmis dans la direction opposée, le flux du liquide fait ralentir la vitesse de propagation du son. La différence de temps obtenue est directement proportionnelle à la vitesse du flux dans la conduite. Ayant mesuré la vitesse du flux et connaissant la section de la conduite, le débit peut facilement être calculé.
u.khalil
u.khalil
Des mesures simples pour installer l'U1000 sur la conduite
u.khalil
u.khalil
Le rail de guidage et assemblage de capteur montrant le couplant appliqué
u.khalil
u.khalil
Fixer le rail de guidage et monter le capteur sur la conduite et les vis de desserrage du capteur de verrouillage
u.khalil
u.khalil
Branchez l'alimentation des capteurs à l'assemblage électronique
u.khalil
u.khalil
Cliquez sur l'assemblage électronique sur le guidage de rail et de capteur
u.khalil
Micronics Limited Knaves Beech Business Centre, Davies Way, Loudwater, High Wycombe, Buckinghamshire, United Kingdom, HP10 9QR.
Micronics Ltd accepts no responsibility or liability if any product has not been installed in accordance with the installation instructions applicable to this product.
U1000 dimensions:
Power on configuration:
A
A
BB
46.8
78.4
46.7
47.
0
SECTION A-A
208.4
246.9
SECTION B-B
Ultraflo U1000
U10004-20mA
PULSE
Micr onics U1000xxxxx
U10004-20mA
PULSE
Sig : 87%246.3 1/min
U10004-20mA
PULSE
Enter Pipe ID :050.0 mm
U10004-20mA
PULSE
Checking Signals. . . . .
5 sec
u.khalil
u.khalil
Configuration de l'alimentation :
u.khalil
u.khalil
Dimensions du U1000 :
u.khalil
u.khalil
42/46 rue du 8 mai 1945 93382 PIERREFITTE CEDEX, FRANCE 01 42 35 33 33 01 42 35 04 98 [email protected]