T o t a l S o l u t i o n o f M a r i n e C a b l e
Halogen free & Mud resistant Offshore cable
NEK-606 (2004) IEC 60092-350, 353, 354, 376
02 Offshore Cable
OFFSHORE CABLETotal Solution of Marine Cable
In the fast-changing global era, when companies are repeating challenges and setbacks TMC has grown continuously creating a new paradigm in the marine cable industry in Korea.
Since establishment in 1991, we have been involved in marine and other special cable business.TMC started to produce indoor optical fiber cables in 2000, and in 2005, completed the new factory in Ipjang,giving us the grandiosity of a company that is the biggest of its kind in Korea.
TMC has acquired certificates from 9 classification societies around the world, and exports to many countries.A corporation marching toward the future through continuous R&D, best quality and customer service!Becoming the best brand in the world based on the management philosophy.That is the dream and vision of TMC.
TMC, a marine cable company representing korea makes happy technology.
OFFSHORE CABLE
03Offshore Cable
CompanyHistory
Certificates
Establishment as Seojin Industry Co., Ltd.
ISO 9001 Certification by LRQA
ISO 14001 Certification by LRQA
Changed the name of company to TMC Co., Ltd.
Selected as a supplier for °∞DSME, Agbami FPSO Project°±
Selected as Excellent Supplier for Hyundai Mipo Dockyard Co., Ltd.
Received the high quality supplier Certification by DSME.
Korean world-class product award 2007
Award the 700 million dollars export tower
July. ,1991
Dec., 1998
May., 2004
Mar., 2005
Mar., 2006
May., 2006
Mar., 2007
Aug., 2007
Nov., 2007
Received Type Approval Certification for the Shipboard Cables by 9 Classification (ABS, BV, CCS, DNV, GL, KR, LR, NK, RINA)
Received Type Approval Certification for the NEK-606(2004) Off-shore Cables by ABS, DNV, LR
Listed by ETL & Received Type Approval Certification by ABS for the Off-shore Cables
Received Type Approval Certification for the PassengerShip Cables by ABS, DNV, LR, CCS
Received Patent of Paint Resistant Shipboard Cable( Patent Number 10-0627241)
Listed by ETL & Received Type Approval certification by ABC and DNV for the IEEE 1580 Type P Cables
Received Type Approval Certification for the LNG Carrier Cables by ABS, DNV, LR
Received Gost-R certification for the NEK-606(2004) Off-shore Cables by GOSSTANDART
0.6/1kV BFOU
Voltage Fire resisting layer + insulation(EPR) Inner covering(HFC)
Armor(Copper) Sheath(SHF2 or SHF mud)
EEXXAAMMPPLLEE
CCOODDEE DDEESSIIGGNNAATTIIOONN
04 Offshore Cable
Fire resistant tape+insulation (Halogen-free) BEthylene propylene rubber - EPR RCross-linked polyethylene XLPE TThermoplastic compound (Halogen-free) IHalogen-free thermoset compound or EVA UBedding/Inner covering or taping (Halogen-free) FScreen (poss. with PE or PP) YNo armour XCopper wire braid (Tinned or bare) OBronze wire braid BGalvanized steel wire braid CThermoplastic compound (Halogen-free) SHF1 I IHalogen-free thermoset compound, SHF2 UHalogen-free mud resistant thermosetcompound, SHF Mud U
Halogen-free mud resistant thermoset compound B
(i)(c)
(i & c)
Individual screenCollective screenIndividual & Collevtive screen
Materials InsulationBedding/
inner coveringinner sheath
Armor/screen Outer sheath
Added abbreviation
Note). QFCB cables only
NEK-606 (2004), IEC 60092-350, 353, 354, 376
05Offshore Cable
HV power cable
LV power & lighting cable
Instrumentation &Communication cable
Earthing & Bonding wire
VFD cable
Technical information
Flame retardant
Flame retardant
Fire resistance
Flame retardant
Fire resistance
Flame retardant
Flame retardant
Fire resistance
3.6/6kV RFOU, RFBU, RFCU
6/10kV RFOU, RFBU, RFCU
8.7/15kV RFOU, RFBU, RFCU
0.6/1kV RFOU, RFBU, RFCU
0.6/1kV RU
0.6/1kV BFOU, BFBU, BFCU
0.6/1kV BU
250V RFOU(c), RFBU(c), RFCU(c)
250V RFOU(i), RFBU(i), RFCU(i)
250V RFOU(i&c), RFBU(i&c), RFCU(i&c)
250V BFOU(c) , BFBU(c), BFCU(c)
250V BFOU(i) , BFBU(i), BFCU(i)
250V BFOU(i&c), BFBU(i&c), BFCU(i&c)
0.6/1kV UX
0.6/1kV RX
0.6/1kV(1.8/3kV) RFOU(VFD)
0.6/1kV(1.8/3kV) BFOU(VFD)
06 ~10
11 ~ 15
16 ~ 19
20 ~ 23
24 ~ 27
28 ~ 31
32 ~ 34
35 ~ 37
38 ~ 40
41 ~ 43
44 ~ 46
47 ~ 48
49 ~ 51
52 ~ 53
54 ~ 71
Materials Designation Page
3.6/6kV RFOU
6/10kV RFOU
8.7/15kV RFOU
0.6/1kV RFOU
0.6/1kV BFOU
0.6/1kV RU
P2
P3
P4
P1
P5
P18
P2/P9
P3/P10
P4/P11
P1/P8
P5/P12
-
DesignationCable type code
H/F H/F & M/R
[NEK 606 Cable type code]
IINNDDEEXX
0.6/1kV BU
0.6/1kV UX
250V RFOU(i)
250V RFOU(c)
250V BFOU(i)
250V BFOU(c)
P17
P15
S1
S2
S3
S4
-
-
S1/S5
S2/S6
S3/S7
S4/S8
DesignationCable type code
H/F H/F & M/R
Note.- H/F : Halogen free cable- H/F & M/R : Halogen free & Mud resistant cable
3.6/6kV RFOU, RFBU, RFCU
6/10kV RFOU, RFBU, RFCU
8.7/15kV RFOU, RFBU, RFCU 06 ~ 10
HHVV PPoowweerr CCaabbllee
HHVV PPoowweerr CCaabbllee
LV P
ower
& L
ight
ing
Cabl
eIn
stru
men
tatio
n &
Com
mun
icat
ion
Cabl
eVF
D Ca
ble
Earth
ing
& Bo
ndin
g w
ireHV
Pow
er C
able
Tech
nica
l Inf
orm
atio
n
3.6/6kV RFOU, RFBU, RFCU
6/10kV RFOU, RFBU, RFCU
8.7/15kV RFOU, RFBU, RFCU
- Design guide : NEK-606 & IEC 60092-354
- Flame retardant : IEC 60332-1 &
IEC 60332-3 Category A
- Halogen content : IEC 60754-1, 0.5%
- Cold bend / impact : CSA 22.2 No.03 (-40 /-35 )
- Mud resistant : NEK-606 (Mud type only)
- Smoke light transmittance : IEC 61034, 60%
- Sunlight (UV) resistant : UL 1581
AAPPPPLLIICCAATTIIOONN SSTTAANNDDAARRDD
CCAABBLLEE DDEESSIIGGNNAATTIIOONN ((PP22,, PP33,, PP44,, PP22//PP99,, PP33//PP1100,, PP44//PP1111))
1. Conductor2. Conductor screen3. Insulation
4. Insulation screen
5. Cabling
6. Inner covering
7. Armor
8. Sheath
9. Core identification
R
FO
(B,C)
U
Stranded tinned annealed copper wires as per IEC 60228, Class 2
Semi-conducting layer (tape / compound)
EPR as per IEC 60092-351
- Non-metallic part : Semi-conducting layer (tape / compound)
- Metallic part : Copper wire braid
- A suitable separator tape(s) may be applied over the metallic part
- Three metallic braided conductors shall be cabled.
- Flame retardant & non-hygroscopic fillers may be used.
- Suitable tape(s) may be applied on the cabled core.
Flame retardant halogen free thermoset compound
- Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)
- A suitable separator tape(s) may be applied under/over the armor
- SHF2 or SHF Mud as per IEC 60092-359
- Outer sheath color : Red
3C : Black, White, Red
CCOONNSSTTRRUUCCTTIIOONN Classification Code Construction detail
6/10
kV R
FO
U
Note.Flexible cable (Class5 Conductor) can be supplied
NEK-606 (2004), IEC 60092-350, 353, 354, 376
07Offshore Cable
CCAABBLLEE TTYYPPEE :: 33..66//66kkVV RRFFOOUU,, 33..66//66kkVV RRFFBBUUNo. ofCores
ConductorNominal
AreaStrand Dia.
No. mm2 No. / mm mm mm mm mm mm kg/km /km A
Thicknessof
Insulation
Nominaldia.
innercovering
Nominal Tolerance
Overall diameterCable
Weight
ConductorResistance
(at 20°C) (Max.)
Current CarryingCapacity
(Max.) (at 45°C)
08 Offshore Cable
HHVV PPoowweerr CCaabbllee
3C 25 7 / 2.14 6.42 2.5 36.9 44.5 2.1 3,460 0.734 89 Earth 16 7 / 1.70 5.10 1.0
3C 35 7 / 2.52 7.56 2.5 40.5 48.3 2.2 4,180 0.529 105 Earth 25 7 / 2.14 6.42 1.2
3C 50 19 / 1.78 8.90 2.5 43.0 51.0 2.3 4,800 0.391 135 Earth 25 7/ 2.14 6.42 1.2
3C 70 19 / 2.14 10.70 2.5 47.0 55.4 2.5 5,930 0.270 170 Earth 35 7 / 2.52 7.56 1.2
3C 95 19 / 2.52 12.60 2.5 51.8 60.6 2.7 7,350 0.195 205 Earth 50 19 / 1.78 8.90 1.4
3C 120 37 / 2.03 14.21 2.5 55.8 64.8 2.9 8,710 0.154 240 Earth 70 19 / 2.14 10.70 1.4
3C 150 37 / 2.25 15.75 2.5 59.8 69.2 3.1 10,220 0.126 270 Earth 95 19 / 2.52 12.60 1.6
3C 185 37 / 2.52 17.64 2.5 63.8 73.6 3.2 11,830 0.100 305 Earth 95 19 / 2.52 12.60 1.6
3C 240 60 / 2.25 20.25 2.6 70.1 80.3 3.5 14,540 0.0762 365 Earth 120 37 / 2.03 14.21 1.6
10 7 / 1.35 4.05 2.5 15.7 21.0 1.1 740 1.840 71 16 7 / 1.70 5.10 2.5 16.7 22.2 1.2 850 1.160 95 25 7 / 2.14 6.42 2.5 18.0 23.5 1.2 1,000 0.734 125 35 7 / 2.52 7.56 2.5 19.2 24.9 1.3 1,160 0.529 155 50 19 / 1.78 8.90 2.5 20.5 26.2 1.3 1,340 0.391 190 70 19 / 2.14 10.70 2.5 22.3 28.2 1.4 1,630 0.270 240 95 19 / 2.52 12.60 2.5 24.2 30.3 1.5 1,980 0.195 290
120 37 / 2.03 14.21 2.5 25.8 31.9 1.6 2,290 0.154 340 1 150 37 / 2.25 15.75 2.5 27.8 34.1 1.7 2,680 0.126 385
185 37 / 2.52 17.64 2.5 29.6 36.1 1.7 3,130 0.100 440 240 61 / 2.25 20.25 2.6 32.5 39.7 1.9 3,940 0.0762 520 300 61 / 2.52 22.68 2.8 35.7 43.1 2.0 4,800 0.0607 590 400 61 / 2.90 26.10 3.0 39.9 47.7 2.2 6,050 0.0475 670 500 61 / 3.20 28.80 3.2 43.0 51.0 2.3 7,090 0.0369 720 630 91 / 3.00 33.00 3.2 47.2 55.6 2.5 8,810 0.0286 780 10 7 / 1.35 4.05 2.5 31.9 39.1 1.9 2,360 1.840 50 16 7 / 1.70 5.10 2.5 34.1 41.5 2.0 2,740 1.160 67 25 7 / 2.14 6.42 2.5 36.9 44.5 2.1 3,280 0.734 89 35 7 / 2.52 7.56 2.5 39.9 47.7 2.2 3,860 0.529 105 50 19 / 1.78 8.90 2.5 42.7 50.7 2.3 4,500 0.391 135
3 70 19 / 2.14 10.70 2.5 46.5 54.9 2.5 5,520 0.270 170 95 19 / 2.52 12.60 2.5 51.0 59.6 2.7 6,770 0.195 205
120 37 / 2.03 14.21 2.5 54.5 63.5 2.8 7,910 0.154 240 150 37 / 2.25 15.75 2.5 57.9 67.1 3.0 9,080 0.126 270 185 37 / 2.52 17.64 2.5 61.8 71.4 3.2 10,630 0.100 305 240 61 / 2.25 20.25 2.6 68.5 78.5 3.4 13,190 0.0762 365
09Offshore Cable
LV P
ower
& L
ight
ing
Cabl
eIn
stru
men
tatio
n &
Com
mun
icat
ion
Cabl
eVF
D Ca
ble
Earth
ing
& Bo
ndin
g w
ireHV
Pow
er C
able
Tech
nica
l Inf
orm
atio
n
CCAABBLLEE TTYYPPEE :: 66//1100kkVV RRFFOOUU,, 66//1100kkVV RRFFBBUUNo. ofCores
ConductorNominal
AreaStrand Dia.
No. mm2 No. / mm mm mm mm mm mm kg/km /km A
Thicknessof
Insulation
Nominaldia.
innercovering
Nominal Tolerance
Overall diameterCable
Weight
ConductorResistance
(at 20°C) (Max.)
Current CarryingCapacity
(Max.) (at 45°C)
3C 25 7 / 2.14 6.42 3.4 41.2 49.2 2.3 4,020 0.734 89 Earth 16 7 / 1.70 5.10 1.0
3C 35 7 / 2.52 7.56 3.4 44.0 52.2 2.4 4,680 0.529 105 Earth 25 7 / 2.14 6.42 1.2
3C 50 19 / 1.78 8.90 3.4 46.5 54.9 2.5 5,320 0.391 135 Earth 25 7 / 2.14 6.42 1.2
3C 70 19 / 2.14 10.70 3.4 50.9 59.5 2.7 6,520 0.270 170 Earth 35 7 / 2.52 7.56 1.2
3C 95 19 / 2.52 12.60 3.4 55.4 64.4 2.9 7,940 0.195 205 Earth 50 19 / 1.78 8.90 1.4
3C 120 37 / 2.03 14.21 3.4 59.2 68.6 3.0 9,340 0.154 240 Earth 70 19 / 2.14 10.70 1.4
3C 150 37 / 2.25 15.75 3.4 63.8 73.6 3.2 10,990 0.126 270 Earth 95 19 / 2.52 12.60 1.6
3C 185 37 / 2.52 17.64 3.4 67.3 77.3 3.4 12,520 0.100 305 Earth 95 19 / 2.52 12.60 1.6
3C 240 61 / 2.25 20.25 3.4 74.0 84.6 3.7 15,560 0.0762 365 Earth 120 37 / 2.03 14.21 1.6
NEK-606 (2004), IEC 60092-350, 353, 354, 376
16 7 / 1.70 5.10 3.4 18.5 24.0 1.3 960 1.160 95 25 7 / 2.14 6.42 3.4 19.8 25.5 1.3 1,130 0.734 125 35 7 / 2.52 7.56 3.4 21.0 26.7 1.4 1,280 0.529 155 50 19 / 1.78 8.90 3.4 22.3 28.2 1.4 1,480 0.391 190 70 19 / 2.14 10.70 3.4 24.1 30.0 1.5 1,770 0.270 240 95 19 / 2.52 12.60 3.4 26.0 32.1 1.6 2,130 0.195 290
120 37 / 2.03 14.21 3.4 28.0 34.3 1.7 2,500 0.154 340 1 150 37 / 2.25 15.75 3.4 29.6 36.1 1.7 2,860 0.126 385
185 37 / 2.52 17.64 3.4 31.4 38.6 1.8 3,410 0.100 440 240 61 / 2.25 20.25 3.4 34.5 41.9 2.0 4,220 0.0762 520 300 61 / 2.52 22.68 3.4 36.9 44.5 2.1 4,960 0.0607 590 400 61 / 2.90 26.10 3.4 40.7 48.5 2.2 6,140 0.0475 670 500 61 / 3.20 28.80 3.4 43.4 51.4 2.4 7,140 0.0369 720 630 91 / 3.00 33.00 3.4 47.6 56.0 2.5 8,870 0.0286 780 16 7 / 1.70 5.10 3.4 38.4 46.0 2.1 3,230 1.160 67 25 7 / 2.14 6.42 3.4 41.2 49.2 2.3 3,820 0.734 89 35 7 / 2.52 7.56 3.4 43.7 51.9 2.4 4,370 0.529 105 50 19 / 1.78 8.90 3.4 46.5 54.9 2.5 5,040 0.391 135 70 19 / 2.14 10.70 3.4 50.8 59.4 2.7 6,140 0.270 170
3 95 19 / 2.52 12.60 3.4 54.9 63.9 2.9 7,400 0.195 205 120 37 / 2.03 14.21 3.4 58.4 67.6 3.0 8,540 0.154 240 150 37 / 2.25 15.75 3.4 61.8 71.4 3.2 9,780 0.126 270 185 37 / 2.52 17.64 3.4 66.1 75.9 3.3 11,410 0.100 305 240 61 / 2.25 20.25 3.4 72.8 83.2 3.6 14,240 0.0762 365
10 Offshore Cable
HHVV PPoowweerr CCaabbllee
CCAABBLLEE TTYYPPEE :: 88..77//1155kkVV RRFFOOUU,, 88..77//1155kkVV RRFFBBUUNo. ofCores
ConductorNominal
AreaStrand Dia.
No. mm2 No. / mm mm mm mm mm mm kg/km /km A
Thicknessof
Insulation
Nominaldia.
innercovering
Nominal Tolerance
Overall diameterCable
Weight
ConductorResistance
(at 20°C) (Max.)
Current CarryingCapacity
(Max.) (at 45°C)
3C 25 7 / 2.14 6.42 4.5 45.9 54.1 2.5 4,670 0.734 89 Earth 16 7 / 1.70 5.10 1.0
3C 35 7 / 2.52 7.56 4.5 48.9 57.5 2.6 5,420 0.529 105 Earth 25 7 / 2.14 6.42 1.2
3C 50 19 / 1.78 8.90 4.5 51.9 60.5 2.7 6,140 0.391 135 Earth 25 7 / 2.14 6.42 1.2
3C 70 19 / 2.14 10.70 4.5 55.6 64.6 2.9 7,320 0.270 170 Earth 35 7 / 2.52 7.56 1.2
3C 95 19 / 2.52 12.60 4.5 59.7 69.1 3.1 8,730 0.195 205 Earth 50 19 / 1.78 8.90 1.4
3C 120 37 / 2.03 14.21 4.5 63.9 73.7 3.2 10,250 0.154 240 Earth 70 19 / 2.14 10.70 1.4
3C 150 37 / 2.25 15.75 4.5 68.0 78.0 3.4 11,830 0.126 270 Earth 95 19 / 2.52 12.60 1.6
3C 185 37 / 2.52 17.64 4.5 71.5 81.9 3.6 13,430 0.100 305 Earth 95 19 / 2.52 12.60 1.6
3C 240 61 / 2.25 20.25 4.5 78.3 89.1 3.9 16,540 0.0762 365 Earth 120 37 / 2.03 14.21 1.6
25 7 / 2.14 6.42 4.5 22.0 27.9 1.4 1,300 0.734 125 35 7 / 2.52 7.56 4.5 23.2 29.1 1.5 1,460 0.529 155 50 19 / 1.78 8.90 4.5 24.5 30.6 1.5 1,660 0.391 190 70 19 / 2.14 10.70 4.5 26.3 32.4 1.6 1,960 0.270 240 95 19 / 2.52 12.60 4.5 28.6 34.9 1.7 2,370 0.195 290
120 37 / 2.03 14.21 4.5 30.2 37.2 1.8 2,810 0.154 340 1 150 37 / 2.25 15.75 4.5 31.8 39.0 1.9 3,180 0.126 385
185 37 / 2.52 17.64 4.5 33.6 40.8 1.9 3,630 0.100 440 240 61 / 2.25 20.25 4.5 36.7 44.3 2.1 4,490 0.0762 520 300 61 / 2.52 22.68 4.5 39.5 47.3 2.2 5,290 0.0607 590 400 61 / 2.90 26.10 4.5 42.9 50.9 2.3 6,450 0.0475 670 500 61 / 3.20 28.80 4.5 45.6 53.8 2.5 7,460 0.0369 720 630 91 / 3.00 33.00 4.5 50.2 58.8 2.7 9,270 0.0286 780 25 7 / 2.14 6.42 4.5 45.9 54.1 2.5 4,430 0.734 89 35 7 / 2.52 7.56 4.5 48.9 57.5 2.6 5,110 0.529 105 50 19 / 1.78 8.90 4.5 51.7 60.5 2.7 5,810 0.391 135 70 19 / 2.14 10.70 4.5 55.6 64.6 2.9 6,900 0.270 170
3 95 19 / 2.52 12.60 4.5 59.7 69.1 3.1 8,210 0.195 205 120 37 / 2.03 14.21 4.5 63.1 72.7 3.2 9,380 0.154 240 150 37 / 2.25 15.75 4.5 67.0 77.0 3.4 10,750 0.126 270 185 37 / 2.52 17.64 4.5 70.8 81.0 3.5 12,330 0.100 305 240 61 / 2.25 20.25 4.5 77.5 88.3 3.8 15,260 0.0762 365
LV P
ower
& L
ight
ing
Cabl
eIn
stru
men
tatio
n &
Com
mun
icat
ion
Cabl
eVF
D Ca
ble
Earth
ing
& Bo
ndin
g w
ireHV
Pow
er C
able
Tech
nica
l Inf
orm
atio
n
NEK-606 (2004), IEC 60092-350, 353, 354, 376
LLVV PPoowweerr && LLiigghhttiinngg CCaabbllee
0.6/1kV RFOU, RFBU, RFCU
0.6/1kV RU
0.6/1kV BFOU, BFBU, BFCU
0.6/1kV BU
11 ~ 15
16 ~ 19
20 ~ 23
24 ~ 27
0.6/1kV RFOU, RFBU, RFCU
- Design guide : NEK-606& IEC 60092-353
- Flame retardant : IEC 60332-1 &
IEC 60332-3 Category A
- Halogen content : IEC 60754-1, 0.5%
- Cold bend / impact : CSA 22.2 No.03 (-40 /-35 )
- Mud resistant : NEK-606 (Mud type only)
- Smoke light transmittance : IEC 61034, 60%
- Sunlight (UV) resistant : UL 1581
AAPPPPLLIICCAATTIIOONN SSTTAANNDDAARRDD
CCAABBLLEE DDEESSIIGGNNAATTIIOONN ((PP11,, PP11//PP88))
1. Conductor2. Insulation
3. Cabling
4. Inner covering
5. Armor
6. Sheath
7. Core identification
R
FO
(B,C)
U
Stranded tinned annealed copper wires as per IEC 60228, Class 2
EPR as per IEC 60092-351
- Insulated cores shall be cabled.
- Flame retardant & non-hygroscopic fillers may be used .
- Suitable tape(s) may be applied on the cabled core.
Flame retardant halogen free thermoset compound
- Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)
- A suitable separator tape(s) may be applied under/over the armor
- SHF2 or SHF Mud as per IEC 60092-359
- Outer sheath color : Black
1C
2C
3C / 2C + E
4C / 3C + E
5C / 4C+E
6C and over
Black or Off-white
Black, White
Black, White, Red
Black, White, Red, Blue
Black No. on white insulation
Black No. on white insulation
-
-
Black, White, G/Y
Black, White, Red, G/Y
Black, White, Red, Blue, G/Y
Black No. on white insulation, G/Y
CCOONNSSTTRRUUCCTTIIOONN Classification
No. of cores Without earth core With earth core
Code Construction detail
0.6
/1kV
RF
OU
12 Offshore Cable
LLVV PPoowweerr && LLiigghhttiinngg CCaabbllee
Note.Flexible cable (Class5 Conductor) can be supplied
13Offshore Cable 13Offshore Cable
CCAABBLLEE TTYYPPEE :: 00..66//11kkVV RRFFOOUU,, 00..66//11kkVV RRFFBBUUNo. ofCores
ConductorNominal
AreaStrand Dia.
No. mm2 No. / mm mm mm mm mm mm kg/km /km M /km A
Thicknessof
Insulation
Nominaldia.
innercovering
Nominal Tolerance
Overall diameter CableWeight
ConductorResistance
(at 20°C) (Max.)
InsulationResistance(at 20°C)(Min,)
Current CarryingCapacity
(Max.) (at 45°C)
2C+E 1.5 7 / 0.53 1.56 1.0 10.2 15.1 0.9 360 12.2 1,300 152C+E 2.5 7 / 0.67 2.01 1.0 11.0 15.9 0.9 410 7.56 1,110 212C+E 4 7 / 0.85 2.55 1.0 12.3 17.4 1.0 51. 4.70 930 292C+E 6 7 / 1.04 3.12 1.0 13.4 18.5 1.0 610 3.110 790 362C+E 10 7 / 1.35 4.05 1.0 15.6 20.9 1.1 820 1.840 640 502C+E 16 7 / 1.70 5.10 1.0 17.7 23.2 1.2 1,080 1.160 530 67
2C 25 7 / 2.14 6.42 1.2 21.1 26.8 1.4 1,460 0.734 510 89Earth 16 7 / 1.70 5.10 1.0 1.160 530
2C 35 7 / 2.52 7.56 1.2 23.6 29.5 1.5 1,870 0.529 440 105Earth 25 7 / 2.14 6.42 1.2 0.734 510
2C 50 19 / 1.78 8.90 1.4 27.2 33.5 1.6 2,370 0.391 440 135Earth 25 7 / 2.14 6.42 1.2 0.734 510
2C 70 19 / 2.14 10.70 1.4 31.4 38.6 1.8 3,260 0.270 380 170Earth 35 7 / 2.52 7.56 1.2 0.529 440
2C 95 19 / 2.52 12.60 1.6 36.2 43.8 2.1 4,280 0.195 370 205Earth 50 19 / 1.78 8.90 1.4 0.391 440
2C 120 37 / 2.03 14.21 1.6 40.0 47.8 2.2 5,260 0.154 330 240Earth 70 19 / 2.14 10.70 1.4 0.270 380
2C 150 37 / 2.25 15.75 1.8 44.2 52.4 2.4 6,430 0.126 330 270Earth 95 19 / 2.52 12.60 1.6 0.195 370
2C 185 37 / 2.52 17.64 2.0 49.2 57.8 2.6 7,730 0.100 330 305Earth 95 19 / 2.52 12.60 1.6 0.195 370
2C 240 61 / 2.25 20.25 2.2 55.7 64.7 2.9 9,800 0.076 320 365Earth 120 37 / 2.03 14.21 1.6 0.154 330
LV P
ower
& L
ight
ing
Cabl
eIn
stru
men
tatio
n &
Com
mun
icat
ion
Cabl
eVF
D Ca
ble
Earth
ing
& Bo
ndin
g w
ireHV
Pow
er C
able
Tech
nica
l Inf
orm
atio
n
NEK-606 (2004), IEC 60092-350, 353, 354, 376
1.5 7 / 0.53 1.59 1.0 9.6 14.5 0.9 320 12.2 1,300 182.5 7 / 0.67 2.01 1.0 10.4 15.3 0.9 370 7.56 1,100 25
4 7 / 0.85 2.55 1.0 11.6 16.5 1.0 440 4.70 920 346 7 / 1.04 3.12 1.0 12.6 17.7 1.0 530 3.110 790 43
10 7 / 1.35 4.05 1.0 14.6 19.9 1.1 690 1.840 640 6016 7 / 1.70 5.10 1.0 16.6 21.9 1.2 890 1.160 530 8125 7 / 2.14 6.42 1.2 20.2 25.9 1.3 1,280 0.734 510 10535 7 / 2.52 7.56 1.2 22.6 28.5 1.4 1,610 0.529 440 135
2 50 19 / 1.78 8.90 1.4 26.0 32.1 1.6 2,060 0.391 440 16570 19 / 2.14 10.70 1.4 30.0 37.0 1.8 2,840 0.270 370 20095 19 / 2.52 12.60 1.6 34.6 42.0 2.0 3,740 0.195 360 249
120 37 / 2.03 14.21 1.6 38.2 45.8 2.1 4,520 0.154 320 288150 37 / 2.25 15.75 1.8 42.2 50.2 2.3 5,450 0.126 330 331185 37 / 2.52 17.64 2.0 46.6 55.0 2.5 6,640 0.100 330 377240 61 / 2.25 20.25 2.2 53.2 62.0 2.8 8,500 0.0762 310 444300 61 / 2.52 22.68 2.4 58.8 68.0 3.0 10,370 0.0607 310 511
1.5 7 / 0.53 1.59 1.0 5.9 10.4 0.7 170 12.2 1,300 212.5 7 / 0.67 2.01 1.0 6.3 10.8 0.7 190 7.56 1,100 30
4 7 / 0.85 2.55 1.0 6.9 11.4 0.8 220 4.70 920 406 7 / 1.04 3.12 1.0 7.4 12.1 0.8 260 3.110 790 51
10 7 / 1.35 4.05 1.0 8.4 13.1 0.8 320 1.840 640 71 16 7/ 1.70 5.10 1.0 9.4 14.1 0.9 400 1.160 530 95 25 7 / 2.14 6.42 1.2 11.2 16.1 0.9 550 0.734 510 125 35 7 / 2.52 7.56 1.2 12.4 17.5 1.0 690 0.529 440 155
1 50 19 / 1.78 8.90 1.4 14.1 19.2 1.1 860 0.391 440 190 70 19 / 2.14 10.70 1.4 15.9 21.2 1.1 1,120 0.270 370 240 95 19 / 2.52 12.60 1.6 18.2 23.7 1.2 1,450 0.195 360 290
120 37 / 2.03 14.21 1.6 19.8 25.5 1.3 1,750 0.154 320 340 150 37 / 2.25 15.75 1.8 21.8 27.5 1.4 2,080 0.126 330 385 185 37 / 2.52 17.64 2.0 24.0 29.9 1.5 2,530 0.100 330 440 240 61 / 2.25 20.25 2.2 27.1 33.4 1.6 3,220 0.0762 310 520 300 61 / 2.52 22.68 2.4 30.3 37.3 1.8 4,060 0.0607 310 590
14 Offshore Cable
LLVV PPoowweerr && LLiigghhttiinngg CCaabbllee
CCAABBLLEE TTYYPPEE :: 00..66//11kkVV RRFFOOUU,, 00..66//11kkVV RRFFBBUU,, 00..66//11kkVV RRFFCCUUNo. ofCores
ConductorNominal
AreaStrand Dia.
No. mm2 No. / mm mm mm mm mm mm kg/km /km M /km A
Thicknessof
Insulation
Nominaldia.
innercovering
Nominal Tolerance
Overall diameter CableWeight
ConductorResistance
(at 20°C) (Max.)
InsulationResistance(at 20°C)(Min,)
Current CarryingCapacity
(Max.) (at 45°C)
3C+E 16 7 / 1.70 5.10 1.0 19.6 25.3 1.3 1,330 1.160 530 673C 25 7 / 2.14 6.42 1.2 22.9 28.8 1.5 1,790 0.734 510 89
Earth 16 7 / 1.70 5.10 1.0 1.160 5303C 35 7 / 2.52 7.56 1.2 26.1 32.2 1.6 2,350 0.529 440 105
Earth 25 7 / 2.14 6.42 1.2 0.734 5103C 50 19 / 1.78 8.90 1.4 29.7 36.2 1.7 2,950 0.391 440 135
Earth 25 7 / 2.14 6.42 1.2 0.734 5103C 70 19 / 2.14 10.70 1.4 33.8 41.2 1.9 4,020 0.270 380 170
Earth 35 7 / 2.52 7.56 1.2 0.529 4403C 95 19 / 2.52 12.60 1.6 39.4 47.2 2.2 5,360 0.195 370 205
Earth 50 19 / 1.78 8.90 1.4 0.391 4403C 120 37 / 2.03 14.21 1.6 43.3 51.3 2.4 6,560 0.154 330 240
Earth 70 19 / 2.14 10.70 1.4 0.270 3803C 150 37 / 2.25 15.75 1.8 48.7 57.3 2.6 8,170 0.126 330 270
Earth 95 19 / 2.52 12.60 1.6 0.195 3703C 185 37 / 2.52 17.64 2.0 52.8 61.6 2.8 9,630 0.100 330 305
Earth 95 19 / 2.52 12.60 1.6 0.195 3703C 240 61 / 2.25 20.25 2.2 59.5 68.9 3.1 12,250 0.076 320 365
Earth 120 37 / 2.03 14.21 1.6 0.154 330
1.5 7 / 0.53 1.59 1.0 10.2 15.1 0.9 360 12.2 1,300 152.5 7 / 0.67 2.01 1.0 11.0 15.9 0.9 410 7.56 1,100 21
4 7 / 0.85 2.55 1.0 12.3 17.4 1.0 510 4.70 920 296 7 / 1.04 3.12 1.0 13.4 18.5 1.0 610 3.110 790 36
10 7 / 1.35 4.05 1.0 15.6 20.9 1.1 820 1.840 640 5016 7 / 1.70 5.10 1.0 17.7 23.2 1.2 1,080 1.160 530 6725 7 / 2.14 6.42 1.2 21.6 27.3 1.4 1,570 0.734 510 89
3 35 7 / 2.52 7.56 1.2 24.2 30.3 1.5 2,000 0.529 440 10550 19 / 1.78 8.90 1.4 28.2 34.5 1.7 2,610 0.391 440 13570 19 / 2.14 10.70 1.4 32.1 39.3 1.9 3,570 0.270 370 17095 19 / 2.52 12.60 1.6 37.1 44.7 2.1 4,730 0.195 360 205
120 37 / 2.03 14.21 1.6 40.9 48.7 2.2 5,730 0.154 320 240150 37 / 2.25 15.75 1.8 45.2 53.4 2.4 6,930 0.126 330 270185 37 / 2.52 17.64 2.0 50.4 59.0 2.7 8,540 0.100 330 305240 61 / 2.25 20.25 2.2 57.1 66.3 3.0 10,930 0.0762 310 365300 61 / 2.52 22.68 2.4 63.1 72.7 3.2 13,380 0.0607 310 415
1.5 7 / 0.53 1.59 1.0 11.1 16.0 0.9 410 12.2 1,300 152.5 7 / 0.67 2.01 1.0 12.1 17.2 1.0 490 7.56 1,100 21
4 7 / 0.85 2.55 1.0 13.5 18.6 1.0 600 4.70 920 296 7 / 1.04 3.12 1.0 14.8 20.1 1.1 730 3.110 790 36
10 7 / 1.35 4.05 1.0 17.2 22.7 1.2 1,000 1.840 640 5016 7 / 1.70 5.10 1.0 19.6 25.3 1.3 1,330 1.160 530 6725 7 / 2.14 6.42 1.2 23.9 29.8 1.5 1,940 0.734 510 8935 7 / 2.52 7.56 1.2 26.8 33.1 1.6 2,490 0.529 440 105
4 50 19 / 1.78 8.90 1.4 31.3 38.5 1.8 3,370 0.391 440 13570 19 / 2.14 10.70 1.4 35.7 43.1 2.0 4,470 0.270 370 17095 19 / 2.52 12.60 1.6 41.6 49.6 2.3 6,000 0.195 360 205
120 37 / 2.03 14.21 1.6 45.5 53.7 2.4 7,250 0.154 320 240150 37 / 2.25 15.75 1.8 50.7 59.3 2.7 8,840 0.126 330 270185 37/ 2.52 17.64 2.0 56.0 65.0 2.9 10,810 0.100 330 305240 61 /2.25 20.25 2.2 63.9 73.7 3.2 13,980 0.0762 310 365300 61 / 2.52 22.68 2.4 70.7 80.9 3.5 17,150 0.0607 310 415
15Offshore Cable
LV P
ower
& L
ight
ing
Cabl
eIn
stru
men
tatio
n &
Com
mun
icat
ion
Cabl
eVF
D Ca
ble
Earth
ing
& Bo
ndin
g w
ireHV
Pow
er C
able
Tech
nica
l Inf
orm
atio
n
CCAABBLLEE TTYYPPEE :: 00..66//11kkVV RRFFOOUU,, 00..66//11kkVV RRFFBBUU,, 00..66//11kkVV RRFFCCUUNo. ofCores
ConductorNominal
AreaStrand Dia.
No. mm2 No. / mm mm mm mm mm mm kg/km /km M /km A
Thicknessof
Insulation
Nominaldia.
innercovering
Nominal Tolerance
Overall diameter CableWeight
ConductorResistance
(at 20°C) (Max.)
InsulationResistance
(at 20°C) (Min,)
Current CarryingCapacity
(Max.) (at 45°C)
NEK-606 (2004), IEC 60092-350, 353, 354, 376
5 1.0 11.5 16.4 1.0 420 107 1.0 12.5 17.6 1.0 480 99 1.0 14.6 19.9 1.1 610 8
12 1.0 16.4 21.7 1.2 730 714 1.0 17.3 22.8 1.2 810 716 1.0 18.3 23.8 1.3 880 719 1.0 7 / 0.43 1.29 1.0 19.3 25.0 1.3 980 18.2 1,490 624 1.0 22.7 28.6 1.4 1,260 627 1.0 23.2 29.1 1.5 1,320 530 1.0 24.1 30.0 1.5 1,410 537 1.0 26.1 32.2 1.6 1,630 544 1.0 29.9 36.9 1.8 2,140 55 1.0 12.3 17.4 1.0 12.2 480 127 1.0 13.4 18.5 1.0 12.2 550 119 1.0 15.7 21.0 1.1 12.2 710 10
12 1.0 17.7 23.2 1.2 12.2 860 914 1.0 18.6 24.1 1.3 12.2 940 916 1.5 7 / 0.53 1.59 1.0 19.7 25.4 1.3 12.2 1,050 1,300 819 1.0 20.8 26.5 1.4 12.2 1,150 824 1.0 24.5 30.6 1.5 12.2 1,510 7 27 1.0 25.1 31.2 1.5 12.2 1,590 730 1.0 26.0 32.1 1.6 12.2 1,690 737 1.0 28.6 34.9 1.7 12.2 2,010 644 1.0 32.3 39.5 1.9 12.2 2,560 65 1.0 13.4 18.5 1.0 570 18 7 1.0 14.6 19.9 1.1 670 169 1.0 17.1 22.6 1.2 860 14
10 1.0 18.7 24.2 1.3 970 1312 1.0 19.3 25.0 1.3 1,060 1314 1.0 20.4 26.1 1.3 1,170 1216 2.5 7 / 0.67 2.01 1.0 21.6 27.3 1.4 1,280 7.56 1,100 1219 1.0 22.8 28.7 1.4 1,440 1120 1.0 24.1 30.0 1.5 1,550 1124 1.0 26.9 33.2 1.6 1,880 1027 1.0 27.9 34.2 1.7 2,020 1030 1.0 29.0 35.3 1.7 2,170 1037 1.0 31.4 38.6 1.8 2,650 944 1.0 35.5 42.9 2.0 3,220 85 1.0 15.0 20.3 1.1 710 227 1.0 16.4 21.7 1.2 850 209 1.0 19.3 25.0 1.3 1,110 18
12 1.0 21.8 27.7 1.4 1,380 1714 1.0 23.0 28.9 1.5 1,520 1616 4 7 / 0.85 2.55 1.0 24.4 30.5 1.5 1,700 4.70 920 1519 1.0 25.8 31.9 1.6 1,900 1424 1.0 30.9 37.9 1.8 2,620 1327 1.0 31.6 38.8 1.9 2,790 1330 1.0 32.8 40.0 1.9 3,000 1237 1.0 35.6 43.0 2.0 3,520 1144 1.0 40.7 48.5 2.2 4,360 11
16 Offshore Cable
LLVV PPoowweerr && LLiigghhttiinngg CCaabbllee
0.6/1kV RU
- Design guide : NEK-606 & IEC 60092-353
- Flame retardant : IEC 60332-1 &
IEC 60332-3 Category A
- Halogen content : IEC 60754-1, 0.5%
- Cold bend / impact : CSA 22.2 No.03 (-40 /-35 )
- Mud resistant : NEK-606 (Mud type only)
- Smoke light transmittance : IEC 61034, 60%
- Sunlight (UV) resistant : UL 1581
AAPPPPLLIICCAATTIIOONN SSTTAANNDDAARRDD
CCAABBLLEE DDEESSIIGGNNAATTIIOONN ((PP1188))
1. Conductor2. Insulation
3. Cabling
4. Sheath
5. Core identification
R
U
Stranded tinned annealed copper wires as per IEC 60228, Class 2
EPR as per IEC 60092-351
- Insulated cores shall be cabled.
- Flame retardant & non-hygroscopic fillers may be used .
- Suitable tape(s) may be applied on the cabled core.
- SHF2 or SHF Mud as per IEC 60092-359
- Outer sheath color : Black
CCOONNSSTTRRUUCCTTIIOONN Classification Code Construction detail
0.6/
1kV
RU
Note.Flexible cable (Class5 Conductor) can be supplied
1C
2C
3C / 2C+E
4C / 3C+E
5C / 4C+E
6C and over
Black or Off-white
Black, White
Black, White, Red
Black, White, Red, Blue
Black No. on white insulation
Black No. on white insulation
-
-
Black, White, G/Y
Black, White, Red, G/Y
Black, White, Red, Blue, G/Y
Black No. on white insulation, G/Y
No. of cores Without earth core With earth core
17Offshore Cable
LV P
ower
& L
ight
ing
Cabl
eIn
stru
men
tatio
n &
Com
mun
icat
ion
Cabl
eVF
D Ca
ble
Earth
ing
& Bo
ndin
g w
ireHV
Pow
er C
able
Tech
nica
l Inf
orm
atio
n
CCAABBLLEE TTYYPPEE :: 00..66//11kkVV RRUUNo. ofCores
ConductorNominal
AreaStrand Dia.
No. mm2 No. / mm mm mm mm mm kg/km /km M /km A
Thicknessof
InsulationNominal Tolerance
Overall diameter CableWeight
ConductorResistance
(at 20°C) (Max.)
InsulationResistance
(at 20°C) (Min,)
Current CarryingCapacity
(Max.) (at 45°C)
NEK-606 (2004), IEC 60092-350, 353, 354, 376
1.5 7 / 0.53 1.59 1.0 5.9 0.5 60 12.2 1,300 212.5 7 / 0.67 2.01 1.0 6.3 0.6 70 7.56 1,100 30
4 7 / 0.85 2.55 1.0 6.9 0.6 90 4.70 920 406 7 / 1.04 3.12 1.0 7.4 0.6 110 3.110 790 51
10 7 / 1.35 4.05 1.0 8.4 0.6 160 1.840 640 7116 7 / 1.70 5.10 1.0 9.6 0.7 230 1.160 530 9525 7 / 2.14 6.42 1.2 11.6 0.8 360 0.734 510 125
1 35 7 / 2.52 7.56 1.2 12.8 0.8 470 0.529 440 15550 19 / 1.78 8.90 1.4 14.7 0.9 610 0.391 440 19070 19 / 2.14 10.70 1.4 16.5 1.0 840 0.270 370 24095 19 / 2.52 12.60 1.6 19.0 1.1 1,140 0.195 360 290
120 37 / 2.03 14.21 1.6 20.8 1.1 1,400 0.154 320 340150 37 / 2.25 15.75 1.8 23.0 1.2 1,720 0.126 330 385185 37 / 2.52 17.64 2.0 25.4 1.3 2,130 0.100 330 440240 61 / 2.25 20.25 2.2 28.7 1.4 2,760 0.0762 310 520300 61/ 2.52 22.68 2.4 31.7 1.6 3,420 0.0607 310 5901.5 7 / 0.53 1.59 1.0 10.1 0.7 160 12.2 1,300 182.5 7 / 0.67 2.01 1.0 10.9 0.7 190 7.56 1,100 25
4 7 / 0.85 2.55 1.0 12.3 0.8 250 4.70 920 346 7 / 1.04 3.12 1.0 13.3 0.8 310 3.110 790 43
10 7 / 1.35 4.05 1.0 15.5 0.9 450 1.840 640 6016 7 / 1.70 5.10 1.0 17.7 1.0 630 1.160 530 8125 7 / 2.14 6.42 1.2 21.5 1.2 960 0.734 510 10535 7 / 2.52 7.56 1.2 24.1 1.3 1,250 0.529 440 135
2 50 19 / 1.78 8.90 1.4 27.9 1.4 1,670 0.391 440 16570 19 / 2.14 10.70 1.4 31.7 1.6 2,260 0.270 370 20095 19 / 2.52 12.60 1.6 36.7 1.8 3,070 0.195 360 249
120 37 / 2.03 14.21 1.6 40.1 1.9 3,750 0.154 320 288150 37 / 2.25 15.75 1.8 44.5 2.1 4,600 0.126 330 331185 37 / 2.52 17.64 2.0 49.3 2.3 5,700 0.100 330 377240 61 / 2.25 20.25 2.2 55.9 2.5 7,390 0.0762 310 444300 61 / 2.52 22.68 2.4 61.9 2.8 9,150 0.0607 310 511
2C+E 1.5 7 / 0.53 1.59 1.0 10.7 0.7 180 12.2 1,300 182C+E 2.5 7 / 0.67 2.01 1.0 11.7 0.8 230 7.56 1,110 252C+E 4 7 / 0.85 2.55 1.0 13.0 0.8 300 4.70 930 342C+E 6 7 / 1.04 3.12 1.0 14.3 0.9 390 3.110 790 432C+E 10 7 / 1.35 4.05 1.0 16.5 1.0 570 1.840 640 602C+E 16 7 / 1.70 5.10 1.0 18.8 1.1 800 1.160 530 81
2C 25 7 / 2.14 6.42 1.2 22.6 1.2 1,140 0.734 510 105Earth 16 7 / 1.70 5.10 1.0 1.160 530
2C 35 7 / 2.52 7.56 1.2 25.3 1.3 1,510 0.529 440 135Earth 25 7 / 2.14 6.42 1.2 0.734 510
2C 50 19 / 1.78 8.90 1.4 29.1 1.5 1,940 0.391 440 165Earth 25 7 / 2.14 6.42 1.2 0.734 510
2C 70 19 / 2.14 10.70 1.4 33.3 1.6 2,650 0.270 380 200Earth 35 7 / 2.52 7.56 1.2 0.529 440
2C 95 19 / 2.52 12.60 1.6 38.5 1.8 3,580 0.195 370 249Earth 50 19 / 1.78 8.90 1.4 0.391 440
2C 120 37 / 2.03 14.21 1.6 42.1 2.0 4,450 0.154 330 288Earth 70 19 / 2.14 10.70 1.4 0.270 380
2C 150 37 / 2.25 15.75 1.8 46.7 2.2 5,540 0.126 330 331Earth 95 19 / 2.52 12.60 1.6 0.195 370
2C 185 37 / 2.52 17.64 2.0 51.5 2.4 6,660 0.100 330 377Earth 95 19 / 2.52 12.60 1.6 0.195 370
2C 240 61 / 2.25 20.25 2.2 58.6 2.6 8,630 0.076 320 444Earth 120 37 / 2.03 14.21 1.6 0.154 330
18 Offshore Cable
LLVV PPoowweerr && LLiigghhttiinngg CCaabbllee
CCAABBLLEE TTYYPPEE :: 00..66//11kkVV RRUUNo. ofCores
ConductorNominal
AreaStrand Dia.
No. mm2 No. / mm mm mm mm mm kg/km /km M /km A
Thicknessof
InsulationNominal Tolerance
Overall diameter CableWeight
ConductorResistance
(at 20°C) (Max.)
InsulationResistance
(at 20°C) (Min,)
Current CarryingCapacity
(Max.) (at 45°C)
1.5 7 / 0.53 1.59 1.0 10.7 0.7 180 12.2 1,300 152.5 7 / 0.67 2.01 1.0 11.7 0.8 230 7.56 1,100 21
4 7 / 0.85 2.55 1.0 13.0 0.8 300 4.70 920 296 7 / 1.04 3.12 1.0 14.3 0.9 390 3.110 790 36
10 7 / 1.35 4.05 1.0 16.5 1.0 570 1.840 640 5016 7 / 1.70 5.10 1.0 18.8 1.1 800 1.160 530 6725 7 / 2.14 6.42 1.2 23.1 1.2 1,230 0.734 510 89
3 35 7 / 2.52 7.56 1.2 25.9 1.3 1,620 0.529 440 10550 19 / 1.78 8.90 1.4 29.7 1.5 2,140 0.391 440 13570 19 / 2.14 10.70 1.4 34.0 1.7 2,940 0.270 370 17095 19 / 2.52 12.60 1.6 39.4 1.9 4,010 0.195 360 205
120 37 / 2.03 14.21 1.6 43.0 2.0 4,910 0.154 320 240150 37 / 2.25 15.75 1.8 47.7 2.2 6,020 0.126 330 270185 37 / 2.52 17.64 2.0 52.9 2.4 7,480 0.100 330 305240 61 / 2.25 20.25 2.2 60.2 2.7 9,740 0.0762 310 365300 61 / 2.52 22.68 2.4 66.6 3.0 12,070 0.0607 310 415
3C+E 1.5 7 / 0.53 1.59 1.0 11.8 0.8 220 12.2 1,300 153C+E 2.5 7 / 0.67 2.01 1.0 12.8 0.8 280 7.56 1,110 213C+E 4 7 / 0.85 2.55 1.0 14.4 0.9 380 4.70 930 293C+E 6 7 / 1.04 3.12 1.0 15.7 0.9 490 3.110 790 363C+E 10 7 / 1.35 4.05 1.0 18.3 1.0 720 1.840 640 503C+E 16 7 / 1.70 5.10 1.0 20.9 1.1 1,020 1.160 530 67
3C 25 7 / 2.14 6.42 1.2 24.4 1.3 1,430 0.734 510 89Earth 16 7 / 1.70 5.10 1.0 1.160 530
3C 35 7 / 2.52 7.56 1.2 28.0 1.4 1,950 0.529 440 105Earth 25 7 / 2.14 6.42 1.2 0.734 510
3C 50 19 / 1.78 8.90 1.4 31.4 1.6 2,460 0.391 440 135Earth 25 7 / 2.14 6.42 1.2 0.734 510
3C 70 19 / 2.14 10.70 1.4 35.9 1.7 3,360 0.270 380 170Earth 35 7 / 2.52 7.56 1.2 0.529 440
3C 95 19 / 2.52 12.60 1.6 41.5 2.0 4,560 0.195 370 205Earth 50 19 / 1.78 8.90 1.4 0.391 440
3C 120 37 / 2.03 14.21 1.6 45.6 2.1 5,690 0.154 330 240Earth 70 19 / 2.14 10.70 1.4 0.270 380
3C 150 37 / 2.25 15.75 1.8 51.0 2.3 7,110 0.126 330 270Earth 95 19 / 2.52 12.60 1.6 0.195 370
3C 185 37 / 2.52 17.64 2.0 55.5 2.5 8,520 0.100 330 305Earth 95 19 / 2.52 12.60 1.6 0.195 370
3C 240 61 / 2.25 20.25 2.2 62.8 2.8 11,000 0.076 320 365Earth 120 37 / 2.03 14.21 1.6 0.154 330
1.5 7 / 0.53 1.59 1.0 11.8 0.8 220 12.2 1,300 152.5 7 / 0.67 2.01 1.0 12.8 0.8 280 7.56 1,100 21
4 7 / 0.85 2.55 1.0 14.4 0.9 380 4.70 920 296 7 / 1.04 3.12 1.0 15.7 0.9 490 3.110 790 36
10 7 / 1.35 4.05 1.0 18.3 1.0 720 1.840 640 5016 7 / 1.70 5.10 1.0 20.9 1.1 1,020 1.160 530 6725 7 / 2.14 6.42 1.2 25.6 1.3 1,570 0.734 510 89
4 35 7 / 2.52 7.56 1.2 28.7 1.4 2,070 0.529 440 10550 19 / 1.78 8.90 1.4 33.2 1.6 2,760 0.391 440 13570 19 / 2.14 10.70 1.4 37.8 1.8 3,780 0.270 370 17095 19 / 2.52 12.60 1.6 43.9 2.1 5,160 0.195 360 205
120 37 / 2.03 14.21 1.6 48.0 2.2 6,330 0.154 320 240150 37 / 2.25 15.75 1.8 53.2 2.4 7,770 0.126 330 270185 37 / 2.52 17.64 2.0 58.9 2.7 9,640 0.100 330 305240 61 / 2.25 20.25 2.2 67.0 3.0 12,550 0.0762 310 365300 61 / 2.52 22.68 2.4 74.4 3.3 15,610 0.0607 310 415
19Offshore Cable
LV P
ower
& L
ight
ing
Cabl
eIn
stru
men
tatio
n &
Com
mun
icat
ion
Cabl
eVF
D Ca
ble
Earth
ing
& Bo
ndin
g w
ireHV
Pow
er C
able
Tech
nica
l Inf
orm
atio
n
CCAABBLLEE TTYYPPEE :: 00..66//11kkVV RRUUNo. ofCores
ConductorNominal
AreaStrand Dia.
No. mm2 No. / mm mm mm mm mm kg/km /km M /km A
Thicknessof
InsulationNominal Tolerance
Overall diameter CableWeight
ConductorResistance
(at 20°C) (Max.)
InsulationResistance
(at 20°C) (Min,)
Current CarryingCapacity
(Max.) (at 45°C)
NEK-606 (2004), IEC 60092-350, 353, 354, 376
5 1.0 11.9 0.8 220 107 1.0 12.9 0.8 260 99 1.0 15.2 0.9 350 8
12 1.0 17.2 1.0 450 714 1.0 18.1 1.0 510 716 1.0 19.1 1.1 570 719 1.0 7 / 0.43 1.29 1.0 20.3 1.1 640 18.2 1,490 624 1.0 23.9 1.3 880 627 1.0 24.4 1.3 930 630 1.0 25.5 1.3 1,010 537 1.0 27.7 1.4 1,200 544 1.0 31.3 1.6 1,520 55 1.0 12.7 0.8 260 127 1.0 13.8 0.9 320 119 1.0 16.3 1.0 430 10
12 1.0 18.5 1.0 560 914 1.0 19.6 1.1 630 916 1.5 7 / 0.53 1.59 1.0 20.7 1.1 710 12.2 1,300 819 1.0 21.8 1.2 790 824 1.0 25.9 1.3 1,090 727 1.0 26.5 1.4 1,160 730 1.0 27.6 1.4 1,270 737 1.0 29.8 1.5 1,490 644 1.0 33.9 1.7 1,890 65 1.0 13.8 0.9 330 187 1.0 15.2 0.9 410 169 1.0 17.9 1.0 560 14
12 1.0 20.3 1.1 730 1314 1.0 21.4 1.2 820 1216 2.5 7 / 0.67 2.01 1.0 22.8 1.2 930 7.56 1,100 1219 1.0 24.0 1.3 1,050 1124 1.0 28.5 1.4 1,430 1027 1.0 29.1 1.5 1,520 1030 1.0 30.4 1.5 1,670 1037 1.0 33.0 1.6 1,990 944 1.0 37.3 1.8 2,490 8
LLVV PPoowweerr && LLiigghhttiinngg CCaabbllee
0.6/1kV BFOU, BFBU, BFCU
- Design guide : NEK-606 & IEC 60092353
- Flame retardant : IEC 60332-1 &
IEC 60332-3 Category A
- Fire resistance : IEC 60331-21, 31
- Halogen content : IEC 60754-1, 0.5%
- Cold bend / impact : CSA 22.2 No.03 (-40 /-35 )
- Mud resistant : NEK-606 (Mud type only)
- Smoke light transmittance : IEC 61034, 60%
- Sunlight (UV) resistant : UL 1581
AAPPPPLLIICCAATTIIOONN SSTTAANNDDAARRDD
CCAABBLLEE DDEESSIIGGNNAATTIIOONN ((PP55,, PP55//PP1122))
1. Conductor2. Fire resisting layer3. Insulation
4. Cabling
5. Inner covering
6. Armor
7. Sheath
8. Core identification
B
FO
(B,C)
U
Stranded tinned annealed copper wires as per IEC 60228, Class 2
Mica/glass tape
EPR as per IEC 60092-351
- Insulated cores shall be cabled.
- Flame retardant & non-hygroscopic fillers may be used .
- Suitable tape(s) may be applied on the cabled core.
Flame retardant halogen free thermoset compound
- Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)
- A suitable separator tape(s) may be applied under/over the armor
- SHF2 or SHF Mud as per IEC 60092-359
- Outer sheath color : Black
CCOONNSSTTRRUUCCTTIIOONN Classification Code Construction detail
20 Offshore Cable
0.6
/1kV
BF
OU
Note.Flexible cable (Class5 Conductor) can be supplied
1C
2C
3C / 2C+E
4C / 3C+E
5C / 4C+E
6C and over
Black or Off-white
Black, White
Black, White, Red
Black, White, Red, Blue
Black No. on white insulation
Black No. on white insulation
-
-
Black, White, G/Y
Black, White, Red, G/Y
Black, White, Red, Blue, G/Y
Black No. on white insulation, G/Y
No. of cores Without earth core With earth core
21Offshore Cable
LV P
ower
& L
ight
ing
Cabl
eIn
stru
men
tatio
n &
Com
mun
icat
ion
Cabl
eVF
D Ca
ble
Earth
ing
& Bo
ndin
g w
ireHV
Pow
er C
able
Tech
nica
l Inf
orm
atio
n
CCAABBLLEE TTYYPPEE :: 00..66//11kkVV BBFFOOUU,, 00..66//11kkVV BBFFBBUUNo. ofCores
ConductorNominal
AreaStrand Dia.
No. mm2 No. / mm mm mm mm mm mm kg/km /km M /km A
Thicknessof
Insulation
Nominaldia.
innercovering
Nominal Tolerance
Overall diameter CableWeight
ConductorResistance
(at 20°C) (Max.)
InsulationResistance
(at 20°C) (Min,)
Current CarryingCapacity
(Max.) (at 45°C)
NEK-606 (2004), IEC 60092-350, 353, 354, 376
1.5 7 / 0.53 1.59 1.0 6.5 11.0 0.7 190 12.2 1,300 212.5 7 / 0.67 2.01 1.0 6.9 11.6 0.8 210 7.56 1,100 30
4 7 / 0.85 2.55 1.0 7.5 12.2 0.8 250 4.70 920 406 7 / 1.04 3.12 1.0 8.0 12.7 0.8 280 3.110 790 51
10 7/ 1.35 4.05 1.0 9.0 13.7 0.8 340 1.840 640 71 16 7/ 1.70 5.10 1.0 10.0 14.9 0.9 430 1.160 530 95 25 7 / 2.14 6.42 1.2 11.7 16.8 1.0 580 0.734 510 125
1 35 7 / 2.52 7.56 1.2 12.9 18.0 1.0 710 0.529 440 155 50 19 / 1.78 8.90 1.4 14.6 19.9 1.1 890 0.391 440 190 70 19 / 2.14 10.70 1.4 16.4 21.7 1.2 1,140 0.270 370 240 95 19 / 2.52 12.60 1.6 18.7 24.2 1.3 1,480 0.195 360 290
120 37 / 2.03 14.21 1.6 20.3 26.0 1.3 1,770 0.154 320 340 150 37 / 2.25 15.75 1.8 22.3 28.2 1.4 2,120 0.126 330 385 185 37 / 2.52 17.64 2.0 24.5 30.6 1.5 2,570 0.100 330 440 240 61 / 2.25 20.25 2.2 28.0 34.3 1.7 3,280 0.0762 310 520 300 61 / 2.52 22.68 2.4 30.8 37.8 1.8 4,090 0.0607 310 5901.5 7 / 0.53 1.59 1.0 10.8 15.7 0.9 370 12.2 1,300 182.5 7 / 0.67 2.01 1.0 11.6 16.5 1.0 420 7.56 1,100 25
4 7 / 0.85 2.55 1.0 12.8 17.9 1.0 500 4.70 920 346 7 / 1.04 3.12 1.0 13.8 18.9 1.1 580 3.110 790 43
10 7 / 1.35 4.05 1.0 15.8 21.1 1.1 760 1.840 640 6016 7 / 1.70 5.10 1.0 17.8 23.3 1.2 970 1.160 530 8125 7 / 2.14 6.42 1.2 21.2 26.9 1.4 1,340 0.734 510 105
2 35 7 / 2.52 7.56 1.2 23.6 29.5 1.5 1,670 0.529 440 13550 19 / 1.78 8.90 1.4 27.0 33.3 1.6 2,150 0.391 440 16570 19 / 2.14 10.70 1.4 31.0 38.0 1.8 2,930 0.270 370 20095 19 / 2.52 12.60 1.6 35.6 43.0 2.0 3,830 0.195 360 249
120 37 / 2.03 14.21 1.6 39.2 47.0 2.2 4,640 0.154 320 288150 37 / 2.25 15.75 1.8 43.2 51.2 2.3 5,560 0.126 330 331185 37 / 2.52 17.64 2.0 47.6 56.0 2.5 6,750 0.100 330 377240 61 / 2.25 20.25 2.2 54.2 63.2 2.8 8,660 0.0762 310 444300 61 / 2.52 22.68 2.4 59.8 69.2 3.1 10,550 0.0607 310 511
2C+E 1.5 7 / 0.53 1.59 1.0 11.5 16.4 1.0 410 12.2 1,300 152C+E 2.5 7 / 0.67 2.01 1.0 12.3 17.4 1.0 470 7.56 1,110 212C+E 4 7 / 0.85 2.55 1.0 13.6 18.7 1.0 570 4.70 930 292C+E 6 7 / 1.04 3.12 1.0 14.7 20.0 1.1 680 3.110 790 362C+E 10 7 / 1.35 4.05 1.0 16.9 22.4 1.2 900 1.840 640 502C+E 16 7 / 1.70 5.10 1.0 19.0 24.5 1.3 1,160 1.160 530 67
2C 25 7 / 2.14 6.42 1.2 22.2 28.1 1.4 1,550 0.734 510 89Earth 16 7 / 1.70 5.10 1.0 1.160 530
2C 35 7 / 2.52 7.56 1.2 24.7 30.8 1.5 1,970 0.529 440 105Earth 25 7 / 2.14 6.42 1.2 0.734 510
2C 50 19 / 1.78 8.90 1.4 28.6 34.9 1.7 2,490 0.391 440 135Earth 25 7 / 2.14 6.42 1.2 0.734 510
2C 70 19 / 2.14 10.70 1.4 32.4 39.6 1.9 3,360 0.270 380 170Earth 35 7 / 2.52 7.56 1.2 0.529 440
2C 95 19 / 2.52 12.60 1.6 37.3 44.9 2.1 4,400 0.195 370 205Earth 50 19 / 1.78 8.90 1.4 0.391 440
2C 120 37 / 2.03 14.21 1.6 41.0 48.8 2.3 5,380 0.154 330 240Earth 70 19 / 2.14 10.70 1.4 0.270 380
2C 150 37 / 2.25 15.75 1.8 45.2 53.4 2.4 6,560 0.126 330 270Earth 95 19 / 2.52 12.60 1.6 0.195 370
2C 185 37 / 2.52 17.64 2.0 50.2 58.8 2.7 7,870 0.100 330 305Earth 95 19 / 2.52 12.60 1.6 0.195 370
2C 240 61 / 2.25 20.25 2.2 56.7 65.9 2.9 9,990 0.076 320 365Earth 120 37 / 2.03 14.21 1.6 0.154 330
22 Offshore Cable
LLVV PPoowweerr && LLiigghhttiinngg CCaabbllee
CCAABBLLEE TTYYPPEE :: 00..66//11kkVV BBFFOOUU,, 00..66//11kkVV BBFFBBUU,, 00..66//11kkVV BBFFCCUUNo. ofCores
ConductorNominal
AreaStrand Dia.
No. mm2 No. / mm mm mm mm mm mm kg/km /km M /km A
Thicknessof
Insulation
Nominaldia.
innercovering
Nominal Tolerance
Overall diameter CableWeight
ConductorResistance
(at 20°C) (Max.)
InsulationResistance
(at 20°C) (Min,)
Current CarryingCapacity
(Max.) (at 45°C)
1.5 7 / 0.53 1.59 1.0 11.5 16.4 1.0 410 12.2 1,300 152.5 7 / 0.67 2.01 1.0 12.3 17.4 1.0 470 7.56 1,100 21
4 7 / 0.85 2.55 1.0 13.6 18.7 1.0 570 4.70 920 296 7 / 1.04 3.12 1.0 14.7 20.0 1.1 680 3.110 790 36
10 7 / 1.35 4.05 1.0 16.9 22.4 1.2 900 1.840 640 5016 7 / 1.70 5.10 1.0 19.0 24.5 1.3 1,160 1.160 530 6725 7 / 2.14 6.42 1.2 22.7 28.6 1.4 1,640 0.734 510 89
3 35 7 / 2.52 7.56 1.2 25.3 31.4 1.6 2,080 0.529 440 10550 19 / 1.78 8.90 1.4 29.3 35.8 1.7 2,710 0.391 440 13570 19 / 2.14 10.70 1.4 33.2 40.4 1.9 3,660 0.270 370 17095 19 / 2.52 12.60 1.6 38.6 46.2 2.1 4,870 0.195 360 205
120 37 / 2.03 14.21 1.6 42.0 50.0 2.3 5,870 0.154 320 240150 37 / 2.25 15.75 1.8 46.3 54.7 2.5 7,080 0.126 330 270185 37 / 2.52 17.64 2.0 51.5 60.3 2.7 8,700 0.100 330 305240 61 / 2.25 20.25 2.2 58.1 67.3 3.0 11,060 0.0762 310 365300 61 / 2.52 22.68 2.4 64.6 74.4 3.3 13,650 0.0607 310 415
3C+E 16 7 / 1.70 5.10 1.0 21.0 26.7 1.4 1,440 1.160 530 673C 25 7 / 2.14 6.42 1.2 24.2 30.3 1.5 1,910 0.734 510 89
Earth 16 7 / 1.70 5.10 1.0 1.160 5303C 35 7 / 2.52 7.56 1.2 27.7 34.0 1.7 2,500 0.529 440 105
Earth 25 7 / 2.14 6.42 1.2 0.734 5103C 50 19 / 1.78 8.90 1.4 30.9 37.9 1.8 3,150 0.391 440 135
Earth 25 7 / 2.14 6.42 1.2 0.734 5103C 70 19 / 2.14 10.70 1.4 34.9 42.3 2.0 4,140 0.270 380 170
Earth 35 7 / 2.52 7.56 1.2 0.529 4403C 95 19 / 2.52 12.60 1.6 40.6 48.4 2.2 5,510 0.195 370 205
Earth 50 19 / 1.78 8.90 1.4 0.391 4403C 120 37 / 2.03 14.21 1.6 44.5 52.7 2.4 6,750 0.154 330 240
Earth 70 19 / 2.14 10.70 1.4 0.270 3803C 150 37 / 2.25 15.75 1.8 49.9 58.5 2.6 8,350 0.126 330 270
Earth 95 19 / 2.52 12.60 1.6 0.195 3703C 185 37 / 2.52 17.64 2.0 54.1 63.1 2.8 9,860 0.100 330 305
Earth 95 19 / 2.52 12.60 1.6 0.195 3703C 240 61 / 2.25 20.25 2.2 60.7 70.1 3.1 12,450 0.076 320 365
Earth 120 37 / 2.03 14.21 1.6 0.154 3301.5 7 / 0.53 1.59 1.0 12.6 17.7 1.0 480 12.2 1,300 152.5 7 / 0.67 2.01 1.0 13.5 18.6 1.0 550 7.56 1,100 21
4 7 / 0.85 2.55 1.0 15.0 20.3 1.1 680 4.70 920 296 7 / 1.04 3.12 1.0 16.2 21.5 1.2 800 3.110 790 36
10 7 / 1.35 4.05 1.0 18.6 24.1 1.3 1,080 1.840 640 5016 7 / 1.70 5.10 1.0 21.0 26.7 1.4 1,420 1.160 530 6725 7 / 2.14 6.42 1.2 25.1 31.2 1.5 2,030 0.734 510 8935 7 / 2.52 7.56 1.2 28.4 34.7 1.7 2,610 0.529 440 105
4 50 19 / 1.78 8.90 1.4 32.5 39.7 1.9 3,460 0.391 440 13570 19 / 2.14 10.70 1.4 36.9 44.5 2.1 4,590 0.270 370 17095 19 / 2.52 12.60 1.6 42.8 50.8 2.3 6,120 0.195 360 205
120 37 / 2.03 14.21 1.6 46.7 55.1 2.5 7,400 0.154 320 240150 37 / 2.25 15.75 1.8 51.9 60.7 2.7 9,010 0.126 330 270185 37 / 2.52 17.64 2.0 57.2 66.4 3.0 11,000 0.100 330 305240 61 / 2.25 20.25 2.2 65.1 74.9 3.3 14,150 0.0762 310 365300 61 / 2.52 22.68 2.4 71.9 82.3 3.6 17,380 0.0607 310 415
23Offshore Cable
LV P
ower
& L
ight
ing
Cabl
eIn
stru
men
tatio
n &
Com
mun
icat
ion
Cabl
eVF
D Ca
ble
Earth
ing
& Bo
ndin
g w
ireHV
Pow
er C
able
Tech
nica
l Inf
orm
atio
n
CCAABBLLEE TTYYPPEE :: 00..66//11kkVV BBFFOOUU,, 00..66//11kkVV BBFFBBUU,, 00..66//11kkVV BBFFCCUUNo. ofCores
ConductorNominal
AreaStrand Dia.
No. mm2 No. / mm mm mm mm mm mm kg/km /km M /km A
Thicknessof
Insulation
Nominaldia.
innercovering
Nominal Tolerance
Overall diameter CableWeight
ConductorResistance
(at 20°C) (Max.)
InsulationResistance
(at 20°C) (Min,)
Current CarryingCapacity
(Max.) (at 45°C)
NEK-606 (2004), IEC 60092-350, 353, 354, 376
5 1.0 13.1 18.2 1.0 500 107 1.0 14.3 19.6 1.1 580 99 1.0 16.8 22.3 1.2 740 8
12 1.0 18.9 24.4 1.3 880 714 1.0 20.0 25.7 1.3 980 716 1.0 7 / 0.43 1.29 1.0 21.1 26.8 1.4 1,070 18.2 1,490 719 1.0 22.3 28.2 1.4 1,180 624 1.0 26.3 32.4 1.6 1,540 627 1.0 26.9 33.2 1.6 1,630 530 1.0 28.4 34.7 1.7 1,780 537 1.0 30.7 37.7 1.8 2,140 544 1.0 34.7 42.1 2.0 2,630 55 1.0 13.9 19.0 1.1 550 127 1.0 15.2 20.5 1.1 650 119 1.0 17.8 23.3 1.2 830 10
12 1.0 20.2 25.9 1.3 1,030 914 1.0 21.3 27.0 1.4 1,120 916 1.5 7 / 0.53 1.59 1.0 22.5 28.4 1.4 1,240 12.2 1,300 819 1.0 23.8 29.7 1.5 1,370 824 1.0 28.5 34.8 1.7 1,840 727 1.0 29.2 35.7 1.7 1,950 730 1.0 30.3 37.3 1.8 2,170 737 1.0 32.8 40.0 1.9 2,510 644 1.0 37.1 44.7 2.1 3,090 65 1.0 15.0 20.3 1.1 650 187 1.0 16.4 21.7 1.2 760 169 1.0 19.3 25.0 1.3 1,000 14
12 1.0 21.8 27.7 1.4 1,230 1314 1.0 23.0 28.9 1.5 1,350 1216 2.5 7 / 0.67 2.01 1.0 24.4 30.5 1.5 1,510 7.56 1,100 1219 1.0 25.8 31.9 1.6 1,670 1124 1.0 30.9 37.9 1.8 2,330 1027 1.0 31.6 38.8 1.9 2,470 1030 1.0 32.8 40.0 1.9 2,640 1037 1.0 35.6 43.0 2.0 3,070 944 1.0 40.7 48.5 2.2 3,830 85 1.0 16.6 21.9 1.2 800 227 1.0 18.2 23.7 1.2 960 209 1.0 21.4 27.1 1.4 1,240 18
12 1.0 24.3 30.4 1.5 1,560 1714 1.0 25.7 31.8 1.6 1,730 1616 4 7 / 0.85 2.55 1.0 27.2 33.5 1.6 1,930 4.70 920 1519 1.0 29.2 35.7 1.7 2,200 1424 1.0 34.5 41.9 2.0 3,000 1327 1.0 35.3 42.7 2.0 3,170 1330 1.0 36.7 44.3 2.1 3,430 1237 1.0 40.2 48.0 2.2 4,060 1144 1.0 45.5 53.7 2.4 4,990 11
24 Offshore Cable
LLVV PPoowweerr && LLiigghhttiinngg CCaabbllee
0.6/1kV BU
- Design guide : NEK-606 & IEC 60092-353
- Flame retardant : IEC 60332-1 &
IEC 60332-3 Category A
- Fire resistance : IEC 60331-21, 31
- Halogen content : IEC 60754-1, 0.5%
- Cold bend / impact : CSA 22.2 No.03 (-40 /-35 )
- Mud resistant : NEK-606 (Mud type only)
- Smoke light transmittance : IEC 61034, 60%
- Sunlight (UV) resistant : UL 1581
AAPPPPLLIICCAATTIIOONN SSTTAANNDDAARRDD
CCAABBLLEE DDEESSIIGGNNAATTIIOONN ((PP1177))
1. Conductor2. Fire resisting layer3. Insulation
4. Cabling
5. Sheath
6. Core identification
B
U
Stranded tinned annealed copper wires as per IEC 60228, Class 2
Mica/glass tape
EPR as per IEC 60092-351
- Insulated cores shall be cabled.
- Flame retardant & non-hygroscopic fillers may be used .
- Suitable tape(s) may be applied on the cabled core.
- SHF2 or SHF Mud as per IEC 60092-359
- Outer sheath color : Black
CCOONNSSTTRRUUCCTTIIOONN Classification Code Construction detail
0.6/
1KV
BU
1C
2C
3C / 2C + E
4C / 3C + E
5C / 4C+E
6C and over
Black or Off-white
Black, White
Black, White, Red
Black, White, Red, Blue
Black No. on white insulation
Black No. on white insulation
-
-
Black, White, G/Y
Black, White, Red, G/Y
Black, White, Red, Blue, G/Y
Black No. on white insulation, G/Y
No. of cores Without earth core With earth core
Note.Flexible cable (Class5 Conductor) can be supplied
25Offshore Cable
LV P
ower
& L
ight
ing
Cabl
eIn
stru
men
tatio
n &
Com
mun
icat
ion
Cabl
eVF
D Ca
ble
Earth
ing
& Bo
ndin
g w
ireHV
Pow
er C
able
Tech
nica
l Inf
orm
atio
n
CCAABBLLEE TTYYPPEE :: 00..66//11kkVV BBUUNo. ofCores
ConductorNominal
AreaStrand Dia.
No. mm2 No. / mm mm mm mm mm kg/km /km M /km A
Thicknessof
InsulationNominal Tolerance
Overall diameter CableWeight
ConductorResistance
(at 20°C) (Max.)
InsulationResistance
(at 20°C) (Min,)
Current CarryingCapacity
(Max.) (at 45°C)
NEK-606 (2004), IEC 60092-350, 353, 354, 376
1.5 7 / 0.53 1.59 1.0 6.5 0.6 70 12.2 1,300 212.5 7 / 0.67 2.01 1.0 6.9 0.6 80 7.56 1,100 30
4 7 / 0.85 2.55 1.0 7.5 0.6 100 4.70 920 406 7 / 1.04 3.12 1.0 8.0 0.6 120 3.110 790 51
10 7 / 1.35 4.05 1.0 9.2 0.7 180 1.840 640 7116 7 / 1.70 5.10 1.0 10.2 0.7 250 1.160 530 9525 7 / 2.14 6.42 1.2 12.1 0.8 370 0.734 510 125
1 35 7 / 2.52 7.56 1.2 13.3 0.8 480 0.529 440 15550 19 / 1.78 8.90 1.4 15.2 0.9 630 0.391 440 19070 19 / 2.14 10.70 1.4 17.2 1.0 860 0.270 370 24095 19 / 2.52 12.60 1.6 19.7 1.1 1,160 0.195 360 290
120 37 / 2.03 14.21 1.6 21.3 1.2 1,420 0.154 320 340150 37 / 2.25 15.75 1.8 23.5 1.2 1,730 0.126 330 385185 37 / 2.52 17.64 2.0 25.9 1.3 2,150 0.100 330 440240 61 / 2.25 20.25 2.2 29.2 1.5 2,780 0.0762 310 520300 61 / 2.52 22.68 2.4 32.2 1.6 3,440 0.0607 310 5901.5 7 / 0.53 1.59 1.0 11.5 0.8 190 12.2 1,300 182.5 7 / 0.67 2.01 1.0 12.3 0.8 230 7.56 1,100 25
4 7 / 0.85 2.55 1.0 13.5 0.8 290 4.70 920 346 7 / 1.04 3.12 1.0 14.7 0.9 360 3.110 790 43
10 7 / 1.35 4.05 1.0 16.9 1.0 510 1.840 640 6016 7 / 1.70 5.10 1.0 18.9 1.1 680 1.160 530 8125 7 / 2.14 6.42 1.2 22.7 1.2 1,020 0.734 510 105
2 35 7 / 2.52 7.56 1.2 25.3 1.3 1,320 0.529 440 13550 19 / 1.78 8.90 1.4 28.9 1.5 1,730 0.391 440 16570 19 / 2.14 10.70 1.4 32.7 1.6 2,330 0.270 370 20095 19 / 2.52 12.60 1.6 37.7 1.8 3,140 0.195 360 249
120 37 / 2.03 14.21 1.6 41.3 2.0 3,850 0.154 320 288150 37 / 2.25 15.75 1.8 45.5 2.1 4,690 0.126 330 331185 37 / 2.52 17.64 2.0 50.3 2.3 5,800 0.100 330 377240 61 / 2.25 20.25 2.2 56.9 2.6 7,500 0.0762 310 444300 61 / 2.52 22.68 2.4 63.1 2.8 9,310 0.0607 310 511
2C+E 1.5 7 / 0.53 1.59 1.0 12.2 0.8 220 12.2 1,300 182C+E 2.5 7 / 0.67 2.01 1.0 13.0 0.8 270 7.56 1,110 252C+E 4 7 / 0.85 2.55 1.0 14.5 0.9 350 4.70 930 342C+E 6 7 / 1.04 3.12 1.0 15.6 0.9 440 3.110 790 432C+E 10 7 / 1.35 4.05 1.0 18.0 1.0 630 1.840 640 602C+E 16 7 / 1.70 5.10 1.0 20.3 1.1 870 1.160 530 81
2C 25 7 / 2.14 6.42 1.2 23.7 1.2 1,190 0.734 510 105Earth 16 7 / 1.70 5.10 1.0 1.160 530
2C 35 7 / 2.52 7.56 1.2 26.4 1.4 1,570 0.529 440 135Earth 25 7 / 2.14 6.42 1.2 0.734 510
2C 50 19 / 1.78 8.90 1.4 30.3 1.5 2,020 0.391 440 165Earth 25 7 / 2.14 6.42 1.2 0.734 510
2C 70 19 / 2.14 10.70 1.4 34.3 1.7 2,720 0.270 380 200Earth 35 7 / 2.52 7.56 1.2 0.529 440
2C 95 19 / 2.52 12.60 1.6 39.6 1.9 3,670 0.195 370 249Earth 50 19 / 1.78 8.90 1.4 0.391 440
2C 120 37 / 2.03 14.21 1.6 43.1 2.0 4,530 0.154 330 288Earth 70 19 / 2.14 10.70 1.4 0.270 380
2C 150 37 / 2.25 15.75 1.8 47.7 2.2 5,630 0.126 330 331Earth 95 19 / 2.52 12.60 1.6 0.195 370
2C 185 37 / 2.52 17.64 2.0 52.7 2.4 6,790 0.100 330 377Earth 95 19 / 2.52 12.60 1.6 0.195 370
2C 240 61 / 2.25 20.25 2.2 59.6 2.7 8,750 0.076 320 444Earth 120 37 / 2.03 14.21 1.6 0.154 330
26 Offshore Cable
LLVV PPoowweerr && LLiigghhttiinngg CCaabbllee
CCAABBLLEE TTYYPPEE :: 00..66//11kkVV BBUUNo. ofCores
ConductorNominal
AreaStrand Dia.
No. mm2 No. / mm mm mm mm mm kg/km /km M /km A
Thicknessof
InsulationNominal Tolerance
Overall diameter CableWeight
ConductorResistance
(at 20°C) (Max.)
InsulationResistance
(at 20°C) (Min,)
Current CarryingCapacity
(Max.) (at 45°C)
1.5 7 / 0.53 1.59 1.0 12.2 0.8 220 12.2 1,300 152.5 7 / 0.67 2.01 1.0 13.0 0.8 270 7.56 1,100 21
4 7 / 0.85 2.55 1.0 14.5 0.9 350 4.70 920 296 7 / 1.04 3.12 1.0 15.6 0.9 440 3.110 790 36
10 7 / 1.35 4.05 1.0 18.0 1.0 630 1.840 640 5016 7 / 1.70 5.10 1.0 20.3 1.1 870 1.160 530 6725 7 / 2.14 6.42 1.2 24.2 1.3 1,280 0.734 510 89
3 35 7 / 2.52 7.56 1.2 27.0 1.4 1,680 0.529 440 10550 19 / 1.78 8.90 1.4 31.0 1.5 2,220 0.391 440 13570 19 / 2.14 10.70 1.4 35.1 1.7 3,010 0.270 370 17095 19 / 2.52 12.60 1.6 40.5 1.9 4,090 0.195 360 205
120 37 / 2.03 14.21 1.6 44.3 2.1 5,020 0.154 320 240150 37 / 2.25 15.75 1.8 48.8 2.3 6,120 0.126 330 270185 37 / 2.52 17.64 2.0 54.0 2.5 7,590 0.100 330 305240 61 / 2.25 20.25 2.2 61.2 2.7 9,840 0.0762 310 365300 61 / 2.52 22.68 2.4 67.7 3.0 12,200 0.0607 310 415
3C+E 1.5 7 / 0.53 1.59 1.0 13.3 0.8 270 12.2 1,300 153C+E 2.5 7 / 0.67 2.01 1.0 14.4 0.9 330 7.56 1,110 213C+E 4 7 / 0.85 2.55 1.0 15.9 0.9 430 4.70 930 293C+E 6 7 / 1.04 3.12 1.0 17.3 1.0 550 3.110 790 363C+E 10 7 / 1.35 4.05 1.0 19.9 1.1 790 1.840 640 503C+E 16 7 / 1.70 5.10 1.0 22.5 1.2 1,100 1.160 530 67
3C 25 7 / 2.14 6.42 1.2 25.9 1.3 1,520 0.734 510 89Earth 16 7 / 1.70 5.10 1.0 1.160 530
3C 35 7 / 2.52 7.56 1.2 29.2 1.5 2,030 0.529 440 105Earth 25 7 / 2.14 6.42 1.2 0.734 510
3C 50 19 / 1.78 8.90 1.4 32.6 1.6 2,550 0.391 440 135Earth 25 7 / 2.14 6.42 1.2 0.734 510
3C 70 19 / 2.14 10.70 1.4 37.0 1.8 3,460 0.270 380 170Earth 35 7 / 2.52 7.56 1.2 0.529 440
3C 95 19 / 2.52 12.60 1.6 42.7 2.0 4,680 0.195 370 205Earth 50 19 / 1.78 8.90 1.4 0.391 440
3C 120 37 / 2.03 14.21 1.6 47.0 2.2 5,840 0.154 330 240Earth 70 19 / 2.14 10.70 1.4 0.270 380
3C 150 37 / 2.25 15.75 1.8 52.4 2.4 7,270 0.126 330 270Earth 95 19 / 2.52 12.60 1.6 0.195 370
3C 185 37 / 2.52 17.64 2.0 56.8 2.6 8,670 0.100 330 305Earth 95 19 / 2.52 12.60 1.6 0.195 370
3C 240 61 / 2.25 20.25 2.2 64.0 2.9 11,180 0.076 320 365Earth 120 37 / 2.03 14.21 1.6 0.154 330
1.5 7 / 0.53 1.59 1.0 13.3 0.8 270 12.2 1,300 152.5 7 / 0.67 2.01 1.0 14.4 0.9 330 7.56 1,100 21
4 7 / 0.85 2.55 1.0 15.9 0.9 430 4.70 920 296 7 / 1.04 3.12 1.0 17.3 1.0 550 3.110 790 36
10 7 / 1.35 4.05 1.0 19.9 1.1 790 1.840 640 5016 7 / 1.70 5.10 1.0 22.5 1.2 1,100 1.160 530 6725 7 / 2.14 6.42 1.2 26.8 1.4 1,630 0.734 510 8935 7 / 2.52 7.56 1.2 29.9 1.5 2,140 0.529 440 105
4 50 19 / 1.78 8.90 1.4 34.4 1.7 2,830 0.391 440 13570 19 / 2.14 10.70 1.4 39.2 1.9 3,880 0.270 370 17095 19 / 2.52 12.60 1.6 45.1 2.1 5,260 0.195 360 205
120 37 / 2.03 14.21 1.6 49.4 2.3 6,460 0.154 320 240150 37 / 2.25 15.75 1.8 54.6 2.5 7,910 0.126 330 270185 37 / 2.52 17.64 2.0 60.3 2.7 9,800 0.100 330 305240 61 / 2.25 20.25 2.2 68.4 3.0 12,720 0.0762 310 365300 61 / 2.52 22.68 2.4 75.6 3.3 15,770 0.0607 310 415
27Offshore Cable
LV P
ower
& L
ight
ing
Cabl
eIn
stru
men
tatio
n &
Com
mun
icat
ion
Cabl
eVF
D Ca
ble
Earth
ing
& Bo
ndin
g w
ireHV
Pow
er C
able
Tech
nica
l Inf
orm
atio
n
CCAABBLLEE TTYYPPEE :: 00..66//11kkVV BBUUNo. ofCores
ConductorNominal
AreaStrand Dia.
No. mm2 No. / mm mm mm mm mm kg/km /km M /km A
Thicknessof
InsulationNominal Tolerance
Overall diameter CableWeight
ConductorResistance
(at 20°C) (Max.)
InsulationResistance
(at 20°C) (Min,)
Current CarryingCapacity
(Max.) (at 45°C)
NEK-606 (2004), IEC 60092-350, 353, 354, 376
5 1.0 13.5 0.8 260 107 1.0 14.9 0.9 320 99 1.0 17.6 1.0 440 8
12 1.0 19.9 1.1 570 714 1.0 21.0 1.1 640 716 1.0 7 / 0.43 1.29 1.0 22.3 1.2 720 18.2 1,490 719 1.0 23.5 1.2 800 624 1.0 27.9 1.4 1,110 627 1.0 28.5 1.4 1,170 630 1.0 29.6 1.5 1,270 537 1.0 32.1 1.6 1,500 544 1.0 36.5 1.8 1,920 55 1.0 14.5 0.9 320 127 1.0 15.8 0.9 380 119 1.0 18.6 1.0 520 10
12 1.0 21.2 1.1 680 914 1.0 22.5 1.2 770 916 1.5 7 / 0.53 1.59 1.0 23.7 1.2 860 12.2 1,300 819 1.0 25.2 1.3 980 824 1.0 29.7 1.5 1,330 727 1.0 30.6 1.5 1,430 730 1.0 31.7 1.6 1,540 737 1.0 34.4 1.7 1,830 644 1.0 39.1 1.9 2,320 65 1.0 15.6 0.9 390 187 1.0 17.2 1.0 490 169 1.0 20.3 1.1 660 14
12 1.0 23.0 1.2 860 1314 1.0 24.2 1.3 960 1216 2.5 7 / 0.67 2.01 1.0 25.8 1.3 1,090 7.56 1,100 1219 1.0 27.2 1.4 1,230 1124 1.0 32.3 1.6 1,690 1027 1.0 33.2 1.6 1,810 1030 1.0 34.4 1.7 1,960 1037 1.0 37.4 1.8 2,340 944 1.0 42.5 2.0 2,960 8
IInnssttrruummeennttaattiioonn && CCoommmmuunniiccaattiioonn CCaabbllee
250V RFOU(c), RFBU(c), RFCU(c)
250C RFOU(i), RFBU(i), RFCU(i)
250V RFOU(i&c0, RFBU(i&c), RFCU(i&c)
250V BFOU(c), BFBU(c), BFCU(c)
250C BFOU(i), BFBU(i), BFCU(i)
250V BFOU(i&c), BFBU(i&c), BFCU(i&c)
28 ~ 31
32 ~ 34
35 ~ 37
38 ~ 40
41 ~ 43
44 ~ 45
IInnssttrruummeennttaattiioonn &&CCoommmmuunniiccaattiioonn CCaabbllee
29Offshore Cable
LV P
ower
& L
ight
ing
Cabl
eIn
stru
men
tatio
n &
Com
mun
icat
ion
Cabl
eVF
D Ca
ble
Earth
ing
& Bo
ndin
g w
ireHV
Pow
er C
able
Tech
nica
l Inf
orm
atio
n
250V RFOU(c), RFBU(c), RFCU(c)
- Design guide : NEK-606 & IEC 60092-376
- Flame retardant : IEC 60332-1 &
IEC 60332-3 Category A
- Halogen content : IEC 60754-1, 0.5%
- Cold bend / impact : CSA 22.2 No.03 (-40 /-35 )
- Mud resistant : NEK-606 (Mud type only)
- Smoke light transmittance : IEC 61034, 60%
- Sunlight (UV) resistant : UL 1581
AAPPPPLLIICCAATTIIOONN SSTTAANNDDAARRDD
CCAABBLLEE DDEESSIIGGNNAATTIIOONN ((SS22,, SS22//SS66))
1. Conductor2. Insulation3. Twisting
4. Cabling
5. Collective screen6. Inner covering
7. Armor
8. Sheath
9. Core identification
R
(c)FO
(B,C)
U
Stranded tinned annealed copper wires as per IEC 60228, Class 2
EPR as per IEC 60092-351
Two/Three Insulated cores shall be twisted together to form a pair/Triad
- Twisted pairs / triads shall be cabled.
- Flame retardant & non-hygroscopic fillers may be used .
- Suitable tape(s) may be applied on the cabled core.
AL/PS tape + Tinned copper drain wire
Flame retardant halogen free thermoset compound
- Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)
- A suitable separator tape(s) may be applied under/over the armor
- SHF2 or SHF Mud as per IEC 60092-359
- Outer sheath color : Grey (Non-IS Type) or Blue (IS Type)
- Each Pair / Triad : Core color
Pair : Black, Light blue Triad : Black, Light blue, Brown
- Multi Pairs / Triads : Number printing on the insulation or numbered tape
CCOONNSSTTRRUUCCTTIIOONN Classification Code Construction detail
250V
RF
OU
(c)
NEK-606 (2004), IEC 60092-350, 353, 354, 376
Note.Flexible cable (Class5 Conductor) can be supplied
30 Offshore Cable
IInnssttrruummeennttaattiioonn && CCoommmmuunniiccaattiioonn CCaabbllee
CCAABBLLEE TTYYPPEE :: 225500VV RRFFOOUU((cc)),, 225500VV RRFFBBUU((cc)),, 225500VV RRFFCCUU((cc))No. ofPairs
ConductorNominal
AreaStrand
Dia.(ca.)
No. SGMM No. / mm mm mm mm mm mm kg / km /km M /km
Thicknessof
Insulation
Nominaldia.
innercovering
Nominal Tolerance
Overall diameter ConductorResistance
(at 20°C) (Max.)
Cable WeightApprox.
InsulationResistance(at 20°C)(Min.)
1P 0.6 7.1 11.6 0.8 2302P 0.6 10.5 15.2 0.9 3503 P 0.6 11.2 15.9 0.9 3904P 0.6 11.9 16.8 1.0 4407 P 0.6 14.3 19.2 1.1 5808P 0.75 7/ 0.37 1.11 0.6 15.3 20.4 1.1 640 24.8 1,170
10 P 0.6 17.2 22.5 1.2 75012 P 0.6 17.9 23.2 1.2 82014 P 0.6 18.6 23.9 1.3 89016 P 0.6 20.1 25.6 1.3 99019P 0.6 21.0 26.5 1.4 1,0902 4P 0.6 23.9 29.6 1.5 1,31032 P 0.6 27.7 33.8 1.7 1,6801 P 0.6 7.5 12.0 0.8 2502 P 0.6 11.1 15.8 0.9 3703 P 0.6 11.9 16.8 1.0 4304 P 0.6 12.7 17.6 1.0 4907 P 0.6 15.3 20.4 1.1 6608 P 0.6 16.3 21.4 1.2 710
10 P 1.0 7 / 0.43 1.29 0.6 18.4 23.7 1.2 840 18.2 1,05012 P 0.6 19.2 24.5 1.3 93014 P 0.6 20.0 25.5 1.3 1,02016 P 0.6 21.5 27.0 1.4 1,12019 P 0.6 22.6 28.3 1.4 1,26024 P 0.6 25.7 31.6 1.6 1,52032P 0.6 29.7 36.0 1.7 1,9501P 0.7 8.5 13.0 0.8 2902 P 0.7 12.8 17.7 1.0 4503 P 0.7 13.8 18.7 1.0 5304 P 0.7 14.7 19.8 1.1 6007 P 0.7 17.8 23.1 1.2 8308 P 1.5 7 / 0.53 1.59 0.7 19.0 24.3 1.3 910 12.2 1,010
10 P 0.7 21.5 27.0 1.4 1,08012 P 0.7 22.5 28.2 1.4 1,21014 P 0.7 23.4 29.1 1.5 1,33016 P 0.7 25.2 31.1 1.5 1,48019 P 0.7 26.5 32.4 1.6 1,66024 P 0.7 30.6 37.4 1.8 2,16032 P 0.7 34.9 42.1 2.0 2,710
1P 0.7 9.3 13.8 0.9 3302P 0.7 14.2 19.1 1.1 5303P 0.7 15.3 20.4 1.1 6404P 0.7 16.3 21.4 1.2 7307P 0.7 19.8 25.3 1.3 1,0408P 2.5 7 / 0.67 2.01 0.7 21.2 26.7 1.4 1,140 7.56 840
10P 0.7 24.0 29.7 1.5 1,36012P 0.7 25.1 31.0 1.5 1,54014P 0.7 26.1 32.0 1.6 1,70016P 0.7 28.6 34.7 1.7 1,95019P 0.7 30.0 36.8 1.8 2,29024P 0.7 34.2 41.4 2.0 2,80032P 0.7 39.5 47.1 2.2 3,600
31Offshore Cable
LV P
ower
& L
ight
ing
Cabl
eIn
stru
men
tatio
n &
Com
mun
icat
ion
Cabl
eVF
D Ca
ble
Earth
ing
& Bo
ndin
g w
ireHV
Pow
er C
able
Tech
nica
l Inf
orm
atio
n
CCAABBLLEE TTYYPPEE :: 225500VV RRFFOOUU((cc)),, 225500VV RRFFBBUU((cc)),, 225500VV RRFFCCUU((cc))No. ofTriads
ConductorNominal
AreaStrand
Dia.(ca.)
No. SGMM No. / mm mm mm mm mm mm kg / km /km M /km
Thicknessof
Insulation
Nominaldia.
innercovering
Nominal Tolerance
Overall diameter ConductorResistance
(at 20°C) (Max.)
Cable WeightApprox.
InsulationResistance(at 20°C)(Min.)
NEK-606 (2004), IEC 60092-350, 353, 354, 376
1T 0.6 7.5 12.0 0.8 2502T 0.6 11.5 16.2 0.9 4003T 0.6 12.2 17.1 1.0 4604T 0.6 13.4 18.3 1.0 5307T 0.6 16.8 21.9 1.2 7408T 0.75 7 / 0.37 1.11 0.6 18.0 23.3 1.2 820 24.8 1,170
10T 0.6 20.4 25.9 1.3 97012T 0.6 21.6 27.1 1.4 1,08014T 0.6 22.6 28.3 1.4 1,20016T 0.6 24.0 29.7 1.5 1,31019T 0.6 26.0 31.9 1.6 1,50024T 0.6 29.2 35.3 1.7 1,83032T 0.6 33.6 40.6 1.9 2,4001T 0.6 7.9 12.4 0.8 2702T 0.6 12.2 17.1 1.0 4403T 0.6 13.0 17.9 1.0 5104T 0.6 14.3 19.2 1.1 5907T 0.6 17.9 23.2 1.2 8408T 0.6 19.2 24.5 1.3 930
10T 1.0 7 / 0.43 1.29 0.6 21.8 27.3 1.4 1,100 18.2 1,05012T 0.6 23.1 28.8 1.5 1,24014T 0.6 24.1 29.8 1.5 1,37016T 0.6 25.7 31.6 1.6 1,52019T 0.6 28.2 34.3 1.7 1,78024T 0.6 31.3 38.1 1.8 2,22032T 0.6 36.0 43.2 2.0 2,7901T 0.7 9.0 13.5 0.8 3202T 0.7 14.1 19.0 1.1 5303T 0.7 15.0 20.1 1.1 6304T 0.7 16.6 21.7 1.2 7407T 0.7 21.0 26.5 1.4 1,0908T 1.5 7 / 0.53 1.59 0.7 22.5 28.2 1.4 1,210 12.2 1,010
10T 0.7 25.6 31.5 1.6 1,45012T 0.7 27.6 33.7 1.6 1,69014T 0.7 28.8 34.9 1.7 1,86016T 0.7 30.7 37.5 1.8 2,17019T 0.7 33.2 40.2 1.9 2,47024T 0.7 36.9 44.3 2.1 2,98032T 0.7 42.9 50.7 2.3 3,8301T 0.7 9.9 14.6 0.9 3802T 0.7 15.7 20.8 1.1 6503T 0.7 16.8 21.9 1.2 7704T 0.7 18.5 23.8 1.3 9307T 0.7 23.5 29.2 1.5 1,3808T 2.5 7 / 0.67 2.01 0.7 25.2 31.1 1.5 1,540 7.56 840
10T 0.7 29.2 35.3 1.7 1,90012T 0.7 30.9 37.7 1.8 2,26014T 0.7 32.3 39.3 1.9 2,52016T 0.7 34.4 41.6 2.0 2,81019T 0.7 37.3 44.7 2.1 3,22024T 0.7 41.9 49.7 2.3 3,97032T 0.7 48.6 56.8 2.6 5,110
32 Offshore Cable
IInnssttrruummeennttaattiioonn && CCoommmmuunniiccaattiioonn CCaabbllee
250V RFOU(i), RFBU(i), RFCU(i)
- Design guide : NEK-606 & IEC 60092-376
- Flame retardant : IEC 60332-1 &
IEC 60332-3 Category A
- Halogen content : IEC 60754-1, 0.5%
- Cold bend / impact : CSA 22.2 No.03 (-40 /-35 )
- Mud resistant : NEK-606 (Mud type only)
- Smoke light transmittance : IEC 61034, 60%
- Sunlight (UV) resistant : UL 1581
AAPPPPLLIICCAATTIIOONN SSTTAANNDDAARRDD
CCAABBLLEE DDEESSIIGGNNAATTIIOONN ((SS11,, SS11//SS55))
1. Conductor2. Insulation3. Twisting4. Individual screen
5. Cabling
6. Inner covering
7. Armor
8. Sheath
9. Core identification
R
(i)
FO
(B,C)
U
Stranded tinned annealed copper wires as per IEC 60228, Class 2
EPR as per IEC 60092-351
Two/Three Insulated cores shall be twisted together to form a pair/Triad
AL/PS tape + Tinned copper drain wire
- Twisted pairs / triads shall be cabled.
- Flame retardant & non-hygroscopic fillers may be used .
- Suitable tape(s) may be applied on the cabled core.
Flame retardant halogen free thermoset compound
- Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)
- A suitable separator tape(s) may be applied under/over the armor
- SHF2 or SHF Mud as per IEC 60092-359
- Outer sheath color : Grey (Non-IS Type) or Blue (IS Type)
- Each Pair / Triad : Core color
Pair : Black, Light blue Triad : Black, Light blue, Brown
- Multi Pairs / Triads : Number printing on the insulation or numbered tape
CCOONNSSTTRRUUCCTTIIOONN Classification Code Construction detail
250V
RF
OU
(i)
Note.Flexible cable (Class5 Conductor) can be supplied
33Offshore Cable
LV P
ower
& L
ight
ing
Cabl
eIn
stru
men
tatio
n &
Com
mun
icat
ion
Cabl
eVF
D Ca
ble
Earth
ing
& Bo
ndin
g w
ireHV
Pow
er C
able
Tech
nica
l Inf
orm
atio
n
CCAABBLLEE TTYYPPEE :: 225500VV RRFFOOUU((ii)),, 225500VV RRFFBBUU((ii)),, 225500VV RRFFCCUU((ii))No. ofPairs
ConductorNominal
AreaStrand
Dia.(ca.)
No. SGMM No. / mm mm mm mm mm mm kg / km /km M /km
Thicknessof
Insulation
Nominaldia.
innercovering
Nominal Tolerance
Overall diameter ConductorResistance
(at 20°C) (Max.)
Cable WeightApprox.
InsulationResistance(at 20°C)(Min.)
NEK-606 (2004), IEC 60092-350, 353, 354, 376
1P 0.6 7.1 11.6 0.8 2302P 0.6 10.8 15.5 0.9 3603P 0.6 11.5 16.2 0.9 4104P 0.6 12.3 17.2 1.0 4807P 0.6 14.9 20.0 1.1 6608P 0.75 7 / 0.37 1.11 0.6 15.9 21.0 1.1 720 24.8 1,170
10P 0.6 17.9 23.2 1.2 85012P 0.6 18.7 24.0 1.3 94014P 0.6 19.4 24.9 1.3 1,04016P 0.6 21.0 26.5 1.4 1,15019P 0.6 22.0 27.7 1.4 1,30024P 0.6 25.1 31.0 1.5 1,57032P 0.6 29.0 35.1 1.7 2,0101P 0.6 7.5 12.0 0.8 2502P 0.6 11.5 16.2 0.9 3903P 0.6 12.3 17.2 1.0 4704P 0.6 13.1 18.0 1.0 5307P 0.6 15.9 21.0 1.1 7408P 0.6 17.0 22.3 1.2 820
10P 1.0 7 / 0.43 1.29 0.6 19.2 24.5 1.3 970 18.2 1,05012P 0.6 20.0 25.5 1.3 1,09014P 0.6 20.8 26.3 1.4 1,20016P 0.6 22.5 28.2 1.4 1,34019P 0.6 23.6 29.3 1.5 1,51024P 0.6 26.9 33.0 1.6 1,85032P 0.6 31.1 37.9 1.8 2,4601P 0.7 8.5 13.0 0.8 2902P 0.7 13.2 18.1 1.0 4803P 0.7 14.1 19.0 1.1 5604P 0.7 15.1 20.2 1.1 6507P 0.7 18.4 23.7 1.2 9208P 1.5 7 / 0.53 1.59 0.7 19.7 25.2 1.3 1,030 12.2 1,010
10P 0.7 22.3 28.0 1.4 1,23012P 0.7 23.2 28.9 1.5 1,37014P 0.7 24.2 29.9 1.5 1,52016P 0.7 26.2 32.1 1.6 1,71019P 0.7 27.9 34.0 1.7 1,98024P 0.7 31.8 38.8 1.9 2,52032P 0.7 36.3 43.5 2.0 3,1601P 0.7 9.3 13.8 0.9 3302P 0.7 14.5 19.6 1.1 5603P 0.7 15.6 20.7 1.1 6704P 0.7 16.7 21.8 1.2 7807P 0.7 20.4 25.9 1.3 1,1508P 2.5 7 / 0.67 2.01 0.7 21.8 27.3 1.4 1,270 7.56 840
10P 0.7 24.7 30.6 1.5 1,54012P 0.7 25.8 31.7 1.6 1,73014P 0.7 27.3 33.4 1.6 1,99016P 0.7 29.5 35.8 1.7 2,23019P 0.7 31.0 37.8 1.8 2,62024P 0.7 35.4 42.6 2.0 3,21032P 0.7 40.9 48.5 2.2 4,150
34 Offshore Cable
IInnssttrruummeennttaattiioonn && CCoommmmuunniiccaattiioonn CCaabbllee
CCAABBLLEE TTYYPPEE :: 225500VV RRFFOOUU((ii)),, 225500VV RRFFCCUU((ii)),, 225500VV RRFFBBUU((ii))No. ofTriads
ConductorNominal
AreaStrand
Dia.(ca.)
No. SGMM No. / mm mm mm mm mm mm kg / km /km M /km
Thicknessof
Insulation
Nominaldia.
innercovering
Nominal Tolerance
Overall diameter ConductorResistance
(at 20°C) (Max.)
Cable WeightApprox.
InsulationResistance(at 20°C)(Min.)
1T 0.6 7.5 12.0 0.8 2502T 0.6 11.8 16.5 1.0 4103T 0.6 12.6 17.5 1.0 4904T 0.6 13.8 18.7 1.0 5605T 0.6 15.4 20.5 1.1 6606T 0.6 17.4 22.7 1.2 7707T 0.75 7 / 0.37 1.11 0.6 17.4 22.7 1.2 820 24.8 1,1708T 0.6 18.7 24.0 1.3 900
10T 0.6 21.2 26.7 1.4 1,08012T 0.6 22.5 28.2 1.4 1,22014T 0.6 23.5 29.2 1.5 1,34016T 0.6 25.1 31.0 1.5 1,50019T 0.6 27.5 33.6 1.6 1,76024T 0.6 30.6 37.4 1.8 2,20032T 0.6 35.2 42.4 2.0 2,7701T 0.6 7.9 12.4 0.8 2702T 0.6 12.5 17.4 1.0 4603T 0.6 13.3 18.2 1.0 5404T 0.6 14.7 19.8 1.1 6407T 0.6 18.5 23.8 1.3 9308T 1.0 7 / 0.43 1.29 0.6 19.9 25.4 1.3 1,040 18.2 1,050
10T 0.6 22.6 28.3 1.4 1,24012T 0.6 24.0 29.7 1.5 1,40014T 0.6 25.1 31.0 1.5 1,57016T 0.6 26.7 32.6 1.6 1,73019T 0.6 29.4 35.7 1.7 2,05024T 0.6 32.6 39.6 1.9 2,56032T 0.6 37.9 45.3 2.1 3,3001T 0.7 9.0 13.5 0.8 3202T 0.7 14.4 19.5 1.1 5603T 0.7 15.4 20.5 1.1 6704T 0.7 17.0 22.3 1.2 8007T 0.7 21.6 27.1 1.4 1,1808T 0.7 23.2 28.9 1.5 1,320
10T 1.5 7 / 0.53 1.59 0.7 26.5 32.4 1.6 1,590 12.2 1,01012T 0.7 28.5 34.6 1.7 1,86014T 0.7 29.8 36.1 1.7 2,08016T 0.7 31.7 38.7 1.8 2,41019T 0.7 34.4 41.6 2.0 2,77024T 0.7 38.6 46.0 2.1 3,39032T 0.7 44.5 52.5 2.4 4,3301T 0.7 9.9 14.6 0.9 3802T 0.7 16.0 21.1 1.1 6703T 0.7 17.1 22.4 1.2 8204T 0.7 19.0 24.3 1.3 9907T 0.7 24.1 29.8 1.5 1,4908T 0.7 25.9 31.8 1.6 1,670
10T 2.5 7 / 0.67 2.01 0.7 30.0 36.8 1.8 2,180 7.56 84012T 0.7 31.8 38.8 1.9 2,48014T 0.7 33.3 40.3 1.9 2,76016T 0.7 35.5 42.7 2.0 3,09019T 0.7 38.9 46.5 2.2 3,64024T 0.7 43.2 51.0 2.3 4,39032T 0.7 50.2 58.6 2.6 5,720
35Offshore Cable
LV P
ower
& L
ight
ing
Cabl
eIn
stru
men
tatio
n &
Com
mun
icat
ion
Cabl
eVF
D Ca
ble
Earth
ing
& Bo
ndin
g w
ireHV
Pow
er C
able
Tech
nica
l Inf
orm
atio
n
250V RFOU(i&c), RFBU(i&c), RFCU(i&c)
- Design guide : NEK-606 & IEC 60092-376
- Flame retardant : IEC 60332-1 &
IEC 60332-3 Category A
- Halogen content : IEC 60754-1, 0.5%
- Cold bend / impact : CSA 22.2 No.03 (-40 /-35 )
- Mud resistant : NEK-606 (Mud type only)
- Smoke light transmittance : IEC 61034, 60%
- Sunlight (UV) resistant : UL 1581
AAPPPPLLIICCAATTIIOONN SSTTAANNDDAARRDD
CCAABBLLEE DDEESSIIGGNNAATTIIOONN
1. Conductor2. Insulation3. Twisting4. Individual screen
5. Cabling
6. Collective screen7. Inner covering
8. Armor
9. Sheath
10. Core identification
R
(i)
(c)FO
(B,C)
U
Stranded tinned annealed copper wires as per IEC 60228, Class 2
EPR as per IEC 60092-351
Two/Three Insulated cores shall be twisted together to form a pair/Triad
AL/PS tape + Tinned copper drain wire
- Twisted pairs / triads shall be cabled.
- Flame retardant & non-hygroscopic fillers may be used .
- Suitable tape(s) may be applied on the cabled core.
AL/PS tape + Tinned copper drain wire
Flame retardant halogen free thermoset compound
- Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)
- A suitable separator tape(s) may be applied under/over the armor
- SHF2 or SHF Mud as per IEC 60092-359
- Outer sheath color : Grey (Non-IS Type) or Blue (IS Type)
- Each Pair / Triad : Core color
Á Pair : Black, Light blue Ë Triad : Black, Light blue, Brown
- Multi Pairs / Triads : Number printing on the insulation or numbered tape
CCOONNSSTTRRUUCCTTIIOONN Classification Code Construction detail
250V
RF
OU
(i&
c)
NEK-606 (2004), IEC 60092-350, 353, 354, 376
Note.Flexible cable (Class5 Conductor) can be supplied
36 Offshore Cable
IInnssttrruummeennttaattiioonn && CCoommmmuunniiccaattiioonn CCaabbllee
CCAABBLLEE TTYYPPEE :: 225500VV RRFFOOUU((ii&&cc)),, 225500VV RRFFBBUU((ii&&cc)),, 225500VV RRFFCCUU((ii&&cc))No. ofPairs
ConductorNominal
AreaStrand
Dia.(ca.)
No. SGMM No. / mm mm mm mm mm mm kg / km /km M /km
Thicknessof
Insulation
Nominaldia.
innercovering
Nominal Tolerance
Overall diameter ConductorResistance
(at 20°C) (Max.)
Cable WeightApprox.
InsulationResistance(at 20°C)(Min.)
2P 0.6 11.0 15.7 0.9 3803P 0.6 11.7 16.4 1.0 4304P 0.6 12.5 17.4 1.0 4907P 0.6 15.1 20.2 1.1 6808P 0.6 16.1 21.2 1.1 740
10P 0.75 7 / 0.37 1.11 0.6 18.1 23.4 1.2 870 24.8 1,17012P 0.6 18.9 24.2 1.3 96014P 0.6 19.6 25.1 1.3 1,06016P 0.6 21.2 26.7 1.4 1,18019P 0.6 22.2 27.9 1.4 1,33024P 0.6 25.3 31.2 1.5 1,60032P 0.6 29.2 35.3 1.7 2,0402P 0.6 11.7 16.4 1.0 4103P 0.6 12.5 17.4 1.0 4904P 0.6 13.3 18.2 1.0 5507P 0.6 16.1 21.2 1.1 7708P 0.6 17.2 22.5 1.2 850
10P 1.0 7 / 0.43 1.29 0.6 19.4 24.9 1.3 1,010 18.2 1,05012P 0.6 20.2 25.7 1.3 1,12014P 0.6 21.0 26.5 1.4 1,23016P 0.6 22.7 28.4 1.4 1,37019P 0.6 23.8 29.5 1.5 1,54024P 0.6 27.5 33.6 1.6 1,92032P 0.6 31.3 38.1 1.8 2,5002P 0.7 13.4 18.3 1.0 5003P 0.7 14.3 19.2 1.1 5804P 0.7 15.3 20.4 1.1 6705P 0.7 17.3 22.6 1.2 8006P 0.7 18.6 23.9 1.3 8907P 0.7 18.6 23.9 1.3 9508P 1.5 7 / 0.53 1.59 0.7 19.9 25.4 1.3 1,060 12.2 1,010
10P 0.7 22.5 28.2 1.4 1,26012P 0.7 23.4 29.1 1.5 1,40014P 0.7 24.4 30.3 1.5 1,56016P 0.7 26.4 32.3 1.6 1,74019 P 0.7 28.1 34.2 1.7 2,01024P 0.7 32.0 39.0 1.9 2,56032 P 0.7 36.5 43.9 2.1 3,230
2p 0.7 14.7 19.8 1.1 5903p 0.7 15.8 20.9 1.1 7004p 0.7 16.9 22.2 1.2 8207p 0.7 20.6 26.1 1.3 1,1808p 0.7 22.0 27.7 1.4 1,310
10p 2.5 7 / 0.67 2.01 0.7 24.9 30.8 1.5 1,570 7.56 84012p 0.7 26.0 31.9 1.6 1,77014p 0.7 27.5 33.6 1.6 2,02016p 0.7 29.7 36.0 1.7 2,27019p 0.7 31.2 38.0 1.8 2,66024p 0.7 35.6 42.8 2.0 3,26032p 0.7 41.1 48.7 2.2 4,200
37Offshore Cable
LV P
ower
& L
ight
ing
Cabl
eIn
stru
men
tatio
n &
Com
mun
icat
ion
Cabl
eVF
D Ca
ble
Earth
ing
& Bo
ndin
g w
ireHV
Pow
er C
able
Tech
nica
l Inf
orm
atio
n
CCAABBLLEE TTYYPPEE :: 225500VV RRFFOOUU((ii&&cc)),, 225500VV RRFFCCUU((ii&&cc)),, 225500VV RRFFBBUU((ii&&cc))No. of Triads
ConductorNominal
AreaStrand
Dia.(ca.)
No. SGMM No. / mm mm mm mm mm mm kg / km /km M /km
Thicknessof
Insulation
Nominaldia.
innercovering
Nominal Tolerance
Overall diameter ConductorResistance
(at 20°C) (Max.)
Cable WeightApprox.
InsulationResistance(at 20°C)(Min.)
NEK-606 (2004), IEC 60092-350, 353, 354, 376
2P 0.6 12.0 16.9 1.0 4403P 0.6 12.8 17.7 1.0 5104P 0.6 14.0 18.9 1.1 5805P 0.6 15.6 20.7 1.1 6806P 0.6 17.6 22.9 1.2 8007P 0.6 17.6 22.9 1.2 8408P 0.75 7 / 0.37 1.11 0.6 18.9 24.2 1.3 930 24.8 1,170
10P 0.6 21.4 26.9 1.4 1,10012P 0.6 22.7 28.4 1.4 1,25014P 0.6 23.9 29.4 1.5 1,37016P 0.6 25.3 31.2 1.5 1,53019P 0.6 27.7 33.8 1.7 1,79024P 0.6 30.8 37.6 1.8 2,23032P 0.6 35.4 42.6 2.0 2,810
2T 0.6 12.7 17.6 1.0 4803T 0.6 13.5 18.4 1.0 5604T 0.6 14.9 20.0 1.1 6707T 0.6 18.7 24.0 1.3 9608T 0.6 20.1 25.6 1.3 1,070
10T 1.0 7 / 0.43 1.29 0.6 22.8 28.5 1.4 1,270 18.2 1,05012T 0.6 24.2 29.9 1.5 1,43014T 0.6 25.3 31.2 1.5 1,60016T 0.6 26.9 33.0 1.6 1,78019T 0.6 29.6 35.9 1.7 2,09024T 0.6 32.8 39.8 1.9 2,60032T 0.6 38.1 45.5 2.1 3,3502T 0.7 14.6 19.7 1.1 5803T 0.7 15.6 20.7 1.1 6904T 0.7 17.2 22.5 1.2 8307T 0.7 21.8 27.3 1.4 1,2108T 0.7 23.4 29.1 1.5 1,350
10T 1.5 7 / 0.53 1.59 0.7 26.7 32.6 1.6 1,620 12.2 1,01012T 0.7 28.7 34.8 1.7 1,89014T 0.7 30.0 36.8 1.8 2,21016T 0.7 31.9 38.9 1.9 2,45019T 0.7 34.6 41.8 2.0 2,81024T 0.7 38.8 46.2 2.1 3,43032T 0.7 44.7 52.7 2.4 4,3802T 0.7 16.2 21.3 1.2 6903T 0.7 17.3 22.6 1.2 8504T 0.7 19.2 24.5 1.3 1,0207T 0.7 24.3 30.0 1.5 1,5308T 0.7 26.1 32.0 1.6 1,710
10T 2.5 7 / 0.67 2.01 0.7 30.2 37.0 1.8 2,220 7.56 84012T 0.7 32.0 39.0 1.9 2,53014T 0.7 33.5 40.5 1.9 2,81016T 0.7 35.7 42.9 2.0 3,13019T 0.7 39.1 46.7 2.2 3,69024T 0.7 43.4 51.2 2.3 4,45032T 0.7 50.4 58.8 2.7 5,770
38 Offshore Cable
IInnssttrruummeennttaattiioonn && CCoommmmuunniiccaattiioonn CCaabbllee
250V BFOU(c), BFBU(c), BFCU(c)
- Design guide: NEK-606 & IEC 60092-376
- Flame retardant : IEC 60332-1 &
IEC 60332-3 Category A
- Fire resistance : IEC 60331-21, 31
- Halogen content : IEC 60754-1, 0.5%
- Cold bend / impact : CSA 22.2 No.03 (-40 /-35 )
- Mud resistant : NEK-606 (Mud type only)
- Smoke light transmittance : IEC 61034, 60%
- Sunlight (UV) resistant : UL 1581
AAPPPPLLIICCAATTIIOONN SSTTAANNDDAARRDD
CCAABBLLEE DDEESSIIGGNNAATTIIOONN ((SS44,, SS44//SS88))
1. Conductor2. Fire resisting layer3. Insulation4. Twisting
5. Cabling
6. Collective screen7. Inner covering
8. Armor
9. Sheath
10. Core identification
B
(c)FO
(B,C)
U
Stranded tinned annealed copper wires as per IEC 60228, Class 2
Mica/glass tape
EPR as per IEC 60092-351
Two/Three Insulated cores shall be twisted together to form a pair/Triad
- Twisted pairs / triads shall be cabled.
- Flame retardant & non-hygroscopic fillers may be used .
- Suitable tape(s) may be applied on the cabled core.
AL/PS tape + Tinned copper drain wire
Flame retardant halogen free thermoset compound
- Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)
- A suitable separator tape(s) may be applied under/over the armor
- SHF2 or SHF Mud as per IEC 60092-359
- Outer sheath color : Grey (Non-IS Type) or Blue (IS Type)
- Each Pair / Triad : Core color
Pair : Black, Light blue Triad : Black, Light blue, Brown
- Multi Pairs / Triads : Number printing on the insulation or numbered tape
CCOONNSSTTRRUUCCTTIIOONN Classification Code Construction detail
250V
BF
OU
(c)
Note.Flexible cable (Class5 Conductor) can be supplied
39Offshore Cable
LV P
ower
& L
ight
ing
Cabl
eIn
stru
men
tatio
n &
Com
mun
icat
ion
Cabl
eVF
D Ca
ble
Earth
ing
& Bo
ndin
g w
ireHV
Pow
er C
able
Tech
nica
l Inf
orm
atio
n
CCAABBLLEE TTYYPPEE :: 225500VV BBFFOOUU((cc)),, 225500VV BBFFBBUU((cc)),, 225500VV BBFFCCUU((cc))No. ofPairs
ConductorNominal
AreaStrand
Dia.(ca.)
No. SGMM No. / mm mm mm mm mm mm kg / km /km M /km
Thicknessof
Insulation
Nominaldia.
innercovering
Nominal Tolerance
Overall diameter ConductorResistance
(at 20°C) (Max.)
Cable WeightApprox.
InsulationResistance
(at 20°C) (Min.)
NEK-606 (2004), IEC 60092-350, 353, 354, 376
1P 0.6 8.1 12.6 0.8 2602P 0.6 12.2 17.1 1.0 4003P 0.6 13.0 17.9 1.0 4504P 0.6 13.9 18.8 1.1 5007P 0.6 16.8 21.9 1.2 6708P 0.75 7 / 0.37 1.11 0.6 18.0 23.3 1.2 750 24.8 1,170
10P 0.6 20.3 25.8 1.3 88012P 0.6 21.2 26.7 1.4 96014P 0.6 22.0 27.7 1.4 1,05016P 0.6 23.8 29.5 1.5 1,16019P 0.6 24.9 30.8 1.5 1,29024P 0.6 28.8 34.9 1.7 1,59032P 0.6 32.9 39.9 1.9 2,0701P 0.6 8.5 13.0 0.8 2802P 0.6 12.8 17.7 1.0 4403P 0.6 13.8 18.7 1.0 5004P 0.6 14.7 19.8 1.1 5607P 0.6 17.8 23.1 1.2 7608P 1.0 7 / 0.43 1.29 0.6 19.0 24.3 1.3 830 18.2 1,050
10P 0.6 21.5 27.0 1.4 98012P 0.6 22.5 28.2 1.4 1,09014P 0.6 23.4 29.1 1.5 1,18016P 0.6 25.2 31.1 1.5 1,31019P 0.6 26.5 32.4 1.6 1,45024P 0.6 30.6 37.4 1.8 1,90032P 0.6 34.9 42.1 2.0 2,3601P 0.7 9.5 14.2 0.9 3202P 0.7 14.5 19.6 1.1 5203P 0.7 15.6 20.7 1.1 6004P 0.7 16.7 21.8 1.2 6807P 0.7 20.3 25.8 1.3 9408P 1.5 7 / 0.53 1.59 0.7 21.7 27.2 1.4 1,030 12.2 1,010
10P 0.7 24.6 30.5 1.5 1,24012P 0.7 25.7 31.6 1.6 1,37014P 0.7 26.8 32.7 1.6 1,50016P 0.7 29.3 35.4 1.7 1,72019P 0.7 30.8 37.6 1.8 2,02024P 0.7 35.1 42.3 2.0 2,45032P 0.7 40.5 48.1 2.2 3,1301P 0.7 10.3 15.0 0.9 3702P 0.7 15.9 21.0 1.1 6003P 0.7 17.1 22.4 1.2 7104P 0.7 18.3 23.6 1.2 8107P 0.7 22.3 28.0 1.4 1,1608P 2.5 7 / 0.67 2.01 0.7 23.9 29.6 1.5 1,280 7.56 840
10P 0.7 27.5 33.6 1.6 1,58012P 0.7 28.7 34.8 1.7 1,76014P 0.7 29.9 36.2 1.7 1,95016P 0.7 32.3 39.3 1.9 2,28019P 0.7 33.9 41.1 1.9 2,57024P 0.7 39.1 46.7 2.2 3,18032P 0.7 44.7 52.7 2.4 4,000
40 Offshore Cable
IInnssttrruummeennttaattiioonn && CCoommmmuunniiccaattiioonn CCaabbllee
CCAABBLLEE TTYYPPEE :: 225500VV BBFFOOUU((cc)),, 225500VV BBFFBBUU((cc)),, 225500VV BBFFCCUU((cc))No. of Triads
ConductorNominal
AreaStrand
Dia.(ca.)
No. SGMM No. / mm mm mm mm mm mm kg / km /km M /km
Thicknessof
Insulation
Nominaldia.
innercovering
Nominal Tolerance
Overall diameter ConductorResistance
(at 20°C) (Max.)
Cable WeightApprox.
InsulationResistance
(at 20°C) (Min.)
1T 0.6 8.6 13.1 0.8 2902T 0.6 13.4 18.3 1.0 4603T 0.6 14.3 19.2 1.1 5304T 0.6 15.7 20.8 1.1 6207T 0.6 19.8 25.3 1.3 8808T 0.75 7 / 0.37 1.11 0.6 21.3 26.8 1.4 960 24.8 1,170
10T 0.6 24.2 29.9 1.5 1,14012T 0.6 25.7 31.6 1.6 1,28014T 0.6 26.9 33.0 1.6 1,42016T 0.6 29.0 35.1 1.7 1,59019T 0.6 31.4 38.4 1.8 1,92024T 0.6 34.9 42.1 2.0 2,27032T 0.6 40.5 48.1 2.2 2,8901T 0.6 9.0 13.5 0.8 3102T 0.6 14.1 19.0 1.1 5003T 0.6 15.0 20.1 1.1 5904T 0.6 16.6 21.7 1.2 6807T 0.6 21.0 26.5 1.4 9808T 0.6 22.5 28.2 1.4 1,090
10T 1.0 7 / 0.43 1.29 0.6 25.6 31.5 1.6 1,290 18.2 1,05012T 0.6 27.6 33.7 1.6 1,50014T 0.6 28.8 34.9 1.7 1,64016T 0.6 30.7 37.5 1.8 1,91019T 0.6 33.2 40.2 1.9 2,17024T 0.6 36.9 44.3 2.1 2,59032T 0.6 42.9 50.7 2.3 3,3101T 0.7 10.1 14.8 0.9 3602T 0.7 16.1 21.2 1.1 6103T 0.7 17.1 22.4 1.2 7204T 0.7 18.9 24.2 1.3 8407T 0.7 24.0 29.7 1.5 1,2308T 1.5 7 / 0.53 1.59 0.7 25.8 31.7 1.6 1,370 12.2 1,010
10T 0.7 29.8 36.1 1.7 1,70012T 0.7 31.7 38.7 1.8 2,02014T 0.7 33.1 40.1 1.9 2,22016T 0.7 35.3 42.5 2.0 2,46019T 0.7 38.6 46.0 2.1 2,86024T 0.7 42.9 50.7 2.3 3,44032T 0.7 49.8 58.2 2.6 4,4301T 0.7 10.9 15.6 0.9 4202T 0.7 17.5 22.8 1.2 7203T 0.7 18.7 24.0 1.3 8604T 0.7 20.7 26.2 1.3 1,0307T 0.7 26.2 32.1 1.6 1,5308T 2.5 7 / 0.67 2.01 0.7 28.6 34.7 1.7 1,750 7.56 840
10T 0.7 32.6 39.6 1.9 2,22012T 0.7 34.6 41.8 2.0 2,52014T 0.7 36.2 43.4 2.0 2,78016T 0.7 39.0 46.6 2.2 3,18019T 0.7 42.2 50.0 2.3 3,64024T 0.7 47.0 55.2 2.5 4,40032T 0.7 54.6 63.4 2.8 5,690
41Offshore Cable
LV P
ower
& L
ight
ing
Cabl
eIn
stru
men
tatio
n &
Com
mun
icat
ion
Cabl
eVF
D Ca
ble
Earth
ing
& Bo
ndin
g w
ireHV
Pow
er C
able
Tech
nica
l Inf
orm
atio
n
250V BFOU(i), BFBU(i), BFCU(i)
- Design guide : NEK-606 & IEC 60092-376
- Flame retardant : IEC 60332-1 &
IEC 60332-3 Category A
- Fire resistance : IEC 60331-21, 31
- Halogen content : IEC 60754-1, 0.5%
- Cold bend / impact : CSA 22.2 No.03 (-40 /-35 )
- Mud resistant : NEK-606 (Mud type only)
- Smoke light transmittance : IEC 61034, 60%
- Sunlight (UV) resistant : UL 1581
AAPPPPLLIICCAATTIIOONN SSTTAANNDDAARRDD
CCAABBLLEE DDEESSIIGGNNAATTIIOONN ((SS33,, SS33//SS77))
1. Conductor2. Fire resisting layer3. Insulation4. Twisting5. Individual screen
6. Cabling
7. Inner covering
8. Armor
9. Sheath
10. Core identification
B
(i)
F
O(B,C)
U
Stranded tinned annealed copper wires as per IEC 60228, Class 2
Mica/glass tape
EPR as per IEC 60092-351
Two/Three Insulated cores shall be twisted together to form a pair/Triad
AL/PS tape + Tinned copper drain wire
- Twisted pairs / triads shall be cabled.
- Flame retardant & non-hygroscopic fillers may be used .
- Suitable tape(s) may be applied on the cabled core.
Flame retardant halogen free thermoset compound
- Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)
- A suitable separator tape(s) may be applied under/over the armor
- SHF2 or SHF Mud as per IEC 60092-359
- Outer sheath color : Grey (Non-IS Type) or Blue (IS Type)
- Each Pair / Triad : Core color
Pair : Black, Light blue Triad : Black, Light blue, Brown
- Multi Pairs / Triads : Number printing on the insulation or numbered tape
CCOONNSSTTRRUUCCTTIIOONN Classification Code Construction detail
250V
BF
OU
(i)
NEK-606 (2004), IEC 60092-350, 353, 354, 376
Note.Flexible cable (Class5 Conductor) can be supplied
42 Offshore Cable
IInnssttrruummeennttaattiioonn && CCoommmmuunniiccaattiioonn CCaabbllee
CCAABBLLEE TTYYPPEE :: 225500VV BBFFOOUU((ii)),, 225500VV BBFFBBUU((ii)),, 225500VV BBFFCCUU((ii))No. ofPairs
ConductorNominal
AreaStrand
Dia.(ca.)
No. SGMM No. / mm mm mm mm mm mm kg / km /km M /km
Thicknessof
Insulation
Nominaldia.
innercovering
Nominal Tolerance
Overall diameter ConductorResistance
(at 20°C) (Max.)
Cable WeightApprox.
InsulationResistance
(at 20°C) (Min.)
1P 0.6 8.1 12.6 0.8 2602P 0.6 12.5 17.4 1.0 4203P 0.6 13.4 18.3 1.0 4804P 0.6 14.3 19.2 1.1 5407P 0.6 17.4 22.7 1.2 7608P 0.6 18.6 23.9 1.3 8301P 0.75 7 / 0.37 1.11 0.6 21.0 26.5 1.4 990 24.8 1,170
12P 0.6 21.9 27.6 1.4 1,10014P 0.6 22.8 28.5 1.4 1,20016P 0.6 24.7 30.6 1.5 1,35019P 0.6 25.9 31.8 1.6 1,50024P 0.6 30.0 36.8 1.8 1,97032P 0.6 34.2 41.4 2.0 2,4601P 0.6 8.5 13.0 0.8 2802P 0.6 13.2 18.1 1.0 4603P 0.6 14.1 19.0 1.1 5304P 0.6 15.1 20.2 1.1 6107P 0.6 18.4 23.7 1.2 8508P 0.6 19.7 25.2 1.3 950
10P 1.0 7 / 0.43 1.29 0.6 22.3 28.0 1.4 1,120 18.2 1,05012P 0.6 23.2 28.9 1.5 1,25014P 0.6 24.2 29.9 1.5 1,37016P 0.6 26.2 32.1 1.6 1,54019P 0.6 27.9 34.0 1.7 1,77024P 0.6 31.8 38.8 1.9 2,26032P 0.6 36.3 43.5 2.0 2,8201P 0.7 9.5 14.2 0.9 3202P 0.7 14.9 20.0 1.1 5403P 0.7 16.0 21.1 1.1 6304P 0.7 17.1 22.4 1.2 7407P 0.7 20.9 26.4 1.4 1,0408P 0.7 22.4 28.1 1.4 1,160
10P 1.5 7 / 0.53 1.59 0.7 25.4 31.3 1.6 1,380 12.2 1,01012P 0.7 26.5 32.4 1.6 1,54014P 0.7 28.0 34.1 1.7 1,76016P 0.7 30.3 37.1 1.8 2,06019P 0.7 31.8 38.8 1.9 2,33024P 0.7 36.3 43.5 2.0 2,82032P 0.7 41.9 49.7 2.3 3,6401P 0.7 10.3 15.0 0.9 3702P 0.7 16.2 21.3 1.2 6203P 0.7 17.5 22.8 1.2 7504P 0.7 18.7 24.0 1.3 8707P 0.7 22.9 28.6 1.4 1,2808P 0.7 24.5 30.4 1.5 1,420
10P 2.5 7 / 0.67 2.01 0.7 28.2 34.3 1.7 1,750 7.56 84012P 0.7 29.5 35.8 1.7 1,98014P 0.7 30.7 37.5 1.8 2,29016P 0.7 33.2 40.2 1.9 2,56019P 0.7 34.9 42.1 2.0 2,91024P 0.7 40.3 47.9 2.2 3,62032P 0.7 46.1 54.1 2.5 4,590
CCAABBLLEE TTYYPPEE :: 225500VV BBFFOOUU((ii)),, 225500VV BBFFBBUU((ii)),, 225500VV BBFFCCUU((ii))No. of Triads
ConductorNominal
AreaStrand
Dia.(ca.)
No. SGMM No. / mm mm mm mm mm mm kg / km /km M /km
Thicknessof
Insulation
Nominaldia.
innercovering
Nominal Tolerance
Overall diameter ConductorResistance
(at 20°C) (Max.)
Cable WeightApprox.
InsulationResistance
(at 20°C) (Min.)
43Offshore Cable
LV P
ower
& L
ight
ing
Cabl
eIn
stru
men
tatio
n &
Com
mun
icat
ion
Cabl
eVF
D Ca
ble
Earth
ing
& Bo
ndin
g w
ireHV
Pow
er C
able
Tech
nica
l Inf
orm
atio
n
NEK-606 (2004), IEC 60092-350, 353, 354, 376
1T 0.6 8.6 13.1 0.8 2902T 0.6 13.7 18.6 1.0 4803T 0.6 14.7 19.8 1.1 5704T 0.6 16.2 21.3 1.2 6607T 0.6 20.5 26.0 1.3 9608T 0.75 7 / 0.37 1.11 0.6 22.0 27.7 1.4 1,060 24.8 1,170
10T 0.6 25.1 31.0 1.5 1,27012T 0.6 26.6 32.5 1.6 1,42014T 0.6 28.2 34.3 1.7 1,62016T 0.6 30.1 36.9 1.8 1,89019T 0.6 32.5 39.5 1.9 2,15024T 0.6 36.2 43.4 2.0 2,56032T 0.6 42.1 49.9 2.3 3,3101T 0.6 9.0 13.5 0.8 3102T 0.6 14.4 19.5 1.1 5303T 0.6 15.4 20.5 1.1 6204T 0.6 17.0 22.3 1.2 7407T 0.6 21.6 27.1 1.4 1,0708T 0.6 23.2 28.9 1.5 1,190
10T 1.0 7 / 0.43 1.29 0.6 26.5 32.4 1.6 1,430 18.2 1,05012T 0.6 28.5 34.6 1.7 1,67014T 0.6 29.8 36.1 1.7 1,85016T 0.6 31.7 38.7 1.8 2,16019T 0.6 34.4 41.6 2.0 2,46024T 0.6 38.6 46.0 2.1 3,00032T 0.6 44.5 52.5 2.4 3,8101T 0.7 10.1 14.8 0.9 3602T 0.7 16.4 21.5 1.2 6303T 0.7 17.5 22.8 1.2 7604T 0.7 19.4 24.9 1.3 9107T 0.7 24.7 30.6 1.5 1,3508T 1.5 7 / 0.53 1.59 0.7 26.5 32.4 1.6 1,490 12.2 1,010
10T 0.7 30.7 37.5 1.8 1,95012T 0.7 32.6 39.6 1.9 2,21014T 0.7 34.1 41.3 2.0 2,46016T 0.7 36.3 43.5 2.0 2,71019T 0.7 39.8 47.4 2.2 3,18024T 0.7 44.2 52.2 2.4 3,84032T 0.7 51.4 60.0 2.7 4,9701T 0.7 10.9 15.6 0.9 4202T 0.7 17.8 23.1 1.2 7503T 0.7 19.0 24.3 1.3 9004T 0.7 21.1 26.6 1.4 1,0907T 0.7 26.9 33.0 1.6 1,6708T 2.5 7 / 0.67 2.01 0.7 29.3 35.4 1.7 1,890 7.56 840
10T 0.7 33.5 40.5 1.9 2,40012T 0.7 35.5 42.7 2.0 2,74014T 0.7 37.2 44.6 2.1 3,06016T 0.7 40.1 47.7 2.2 3,48019T 0.7 43.4 51.2 2.3 3,99024T 0.7 48.7 56.9 2.6 4,92032T 0.7 56.2 65.0 2.9 6,300
44 Offshore Cable
IInnssttrruummeennttaattiioonn && CCoommmmuunniiccaattiioonn CCaabbllee
250V BFOU(i&c), BFBU(i&c), BFCU(i&c)
- Design guide : NEK-606 & IEC 60092-376
- Flame retardant : IEC 60332-1 &
IEC 60332-3 Category A
- Fire resistance : IEC 60331-21, 31
- Halogen content : IEC 60754-1, 0.5%
- Cold bend / impact : CSA 22.2 No.03 (-40 /-35 )
- Mud resistant : NEK-606 (Mud type only)
- Smoke light transmittance : IEC 61034, 60%
- Sunlight (UV) resistant : UL 1581
AAPPPPLLIICCAATTIIOONN SSTTAANNDDAARRDD
CCAABBLLEE DDEESSIIGGNNAATTIIOONN
1. Conductor2. Fire resisting layer3. Insulation4. Twisting5. Individual screen
6. Cabling
7. Collective screen8. Inner covering
9. Armor
10. Sheath
11. Core identification
B
(i)
(c)FO
(B,C)
U
Stranded tinned annealed copper wires as per IEC 60228, Class 2
Mica/glass tape
EPR as per IEC 60092-351
Two/Three Insulated cores shall be twisted together to form a pair/Triad
AL/PS tape + Tinned copper drain wire
- Twisted pairs / triads shall be cabled.
- Flame retardant & non-hygroscopic fillers may be used .
- Suitable tape(s) may be applied on the cabled core.
AL/PS tape + Tinned copper drain wire
Flame retardant halogen free thermoset compound
- Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)
- A suitable separator tape(s) may be applied under/over the armor
- SHF2 or SHF Mud as per IEC 60092-359
- Outer sheath color : Grey (Non-IS Type) or Blue (IS Type)
- Each Pair / Triad : Core color
Pair : Black, Light blue Triad : Black, Light blue, Brown
- Multi Pairs / Triads : Number printing on the insulation or numbered tape
CCOONNSSTTRRUUCCTTIIOONN Classification Code Construction detail
250V
BF
OU
(i&
c)
Note.Flexible cable (Class5 Conductor) can be supplied
45Offshore Cable
LV P
ower
& L
ight
ing
Cabl
eIn
stru
men
tatio
n &
Com
mun
icat
ion
Cabl
eVF
D Ca
ble
Earth
ing
& Bo
ndin
g w
ireHV
Pow
er C
able
Tech
nica
l Inf
orm
atio
n
CCAABBLLEE TTYYPPEE :: 225500VV BBFFOOUU((ii&&cc)),, 225500VV BBFFBBUU((ii&&cc)),, 225500VV BBFFCCUU((ii&&cc))No. ofPairs
ConductorNominal
AreaStrand
Dia.(ca.)
No. SGMM No. / mm mm mm mm mm mm kg / km /km M /km
Thicknessof
Insulation
Nominaldia.
innercovering
Nominal Tolerance
Overall diameter ConductorResistance
(at 20°C) (Max.)
Cable WeightApprox.
InsulationResistance
(at 20°C) (Min.)
NEK-606 (2004), IEC 60092-350, 353, 354, 376
2P 0.6 12.7 17.6 1.0 4403P 0.6 13.6 18.5 1.0 5004P 0.6 14.5 19.6 1.1 5707P 0.6 17.6 22.9 1.2 7808P 0.6 18.8 24.1 1.3 860
10P 0.75 7 / 0.37 1.11 0.6 21.2 26.7 1.4 1,010 24.8 1,17012P 0.6 22.1 27.8 1.4 1,13014P 0.6 23.0 28.7 1.4 1,23016P 0.6 24.9 30.8 1.5 1,38019P 0.6 26.1 32.0 1.6 1,53024P 0.6 30.2 37.0 1.8 2,00032P 0.6 34.4 41.6 2.0 2,4902P 0.6 13.4 18.3 1.0 4803P 0.6 14.3 19.2 1.1 5504P 0.6 15.3 20.4 1.1 6307P 0.6 18.6 23.9 1.3 8808P 0.6 19.9 25.4 1.3 970
10P 1.0 7 / 0.43 1.29 0.6 22.5 28.2 1.4 1,150 18.2 1,05012P 0.6 23.4 29.1 1.5 1,28014P 0.6 24.4 30.3 1.5 1,42016P 0.6 26.4 32.3 1.6 1,57019P 0.6 28.1 34.2 1.7 1,81024P 0.6 32.0 39.0 1.9 2,30032P 0.6 36.5 43.9 2.1 2,8802P 0.7 15.1 20.2 1.1 5603P 0.7 16.2 21.3 1.2 6604P 0.7 17.3 22.6 1.2 7607P 0.7 21.1 26.6 1.4 1,0708P 0.7 22.6 28.3 1.4 1,190
10P 1.5 7 / 0.53 1.59 0.7 25.6 31.5 1.6 1,420 12.2 1,01012P 0.7 26.7 32.6 1.6 1,58014P 0.7 28.2 34.3 1.7 1,80016P 0.7 30.5 37.3 1.8 2,10019P 0.7 32.0 39.0 1.9 2,36024P 0.7 36.5 43.9 2.1 2,88032P 0.7 42.1 49.9 2.3 3,6902P 0.7 16.4 21.5 1.2 6503P 0.7 17.7 23.0 1.2 7804P 0.7 18.9 24.2 1.3 9007P 0.7 23.1 28.8 1.5 1,3108P 0.7 24.7 30.6 1.5 1,460
10P 2.5 7 / 0.67 2.01 0.7 28.4 34.5 1.7 1,790 7.56 84012P 0.7 29.7 36.0 1.7 2,02014P 0.7 30.9 37.7 1.8 2,33016P 0.7 33.4 40.4 1.9 2,61019P 0.7 35.1 42.3 2.0 2,95024P 0.7 40.5 48.1 2.2 3,67032P 0.7 46.3 54.3 2.5 4,640
46 Offshore Cable
IInnssttrruummeennttaattiioonn && CCoommmmuunniiccaattiioonn CCaabbllee
CCAABBLLEE TTYYPPEE :: 225500VV BBFFOOUU((ii&&cc)),, 225500VV BBFFBBUU((ii&&cc)),, 225500VV BBFFCCUU((ii&&cc))No. of Triads
ConductorNominal
AreaStrand
Dia.(ca.)
No. SGMM No. / mm mm mm mm mm mm kg / km /km M /km
Thicknessof
Insulation
Nominaldia.
innercovering
Nominal Tolerance
Overall diameter ConductorResistance
(at 20°C) (Max.)
Cable WeightApprox.
InsulationResistance
(at 20°C) (Min.)
2T 0.6 13.9 18.8 1.1 5003T 0.6 14.9 20.0 1.1 5904T 0.6 16.4 21.5 1.2 6807T 0.6 20.7 26.2 1.3 9808T 0.6 22.2 27.9 1.4 1,090
10T 0.75 7 / 0.37 1.11 0.6 25.3 31.2 1.5 1,300 24.8 1,17012T 0.6 26.8 32.7 1.6 1,45014T 0.6 28.4 34.5 1.7 1,65016T 0.6 30.3 37.1 1.8 1,92019T 0.6 32.7 39.7 1.9 2,18024T 0.6 36.4 43.8 2.1 2,62032T 0.6 42.3 50.1 2.3 3,3502T 0.6 14.6 19.7 1.1 5503T 0.6 15.6 20.7 1.1 6504T 0.6 17.2 22.5 1.2 7707T 0.6 21.8 27.3 1.4 1,1008T 0.6 23.4 29.1 1.5 1,220
10T 1.0 7 / 0.43 1.29 0.6 26.7 32.6 1.6 1,460 18.2 1,05012T 0.6 28.7 34.8 1.7 1,70014T 0.6 30.0 36.8 1.8 1,98016T 0.6 31.9 38.9 1.9 2,20019T 0.6 34.6 41.8 2.0 2,51024T 0.6 38.8 46.2 2.1 3,05032T 0.6 44.7 52.7 2.4 3,8602T 0.7 16.6 21.7 1.2 6503T 0.7 17.7 23.0 1.2 7804T 0.7 19.6 25.1 1.3 9407T 0.7 24.9 30.8 1.5 1,3808T 0.7 26.7 32.6 1.6 1,520
10T 1.5 7 / 0.53 1.59 0.7 30.9 37.7 1.8 1,980 12.2 1,01012T 0.7 32.8 39.8 1.9 2,25014T 0.7 34.3 41.5 2.0 2,50016T 0.7 36.5 43.9 2.1 2,77019T 0.7 40.0 47.6 2.2 3,23024T 0.7 44.4 52.4 2.4 3,89032T 0.7 51.6 60.2 2.7 5,0302T 0.7 18.0 23.3 1.2 7703T 0.7 19.2 24.5 1.3 9304T 0.7 21.3 26.8 1.4 1,1207T 0.7 27.5 33.6 1.6 1,7408T 0.7 29.5 35.8 1.7 1,950
10T 2.5 7 / 0.67 2.01 0.7 33.7 40.7 1.9 2,440 7.56 84012T 0.7 35.7 42.9 2.0 2,78014T 0.7 37.4 44.8 2.1 3,11016T 0.7 40.3 47.9 2.2 3,53019T 0.7 43.6 51.4 2.4 4,05024T 0.7 48.9 57.3 2.6 5,00032T 0.7 56.4 65.4 2.9 6,390
LV P
ower
& L
ight
ing
Cabl
eIn
stru
men
tatio
n &
Com
mun
icat
ion
Cabl
eVF
D Ca
ble
Eart
hing
& B
ondi
ng w
ireHV
Pow
er C
able
Tech
nica
l dat
a
NEK-606 (2004), IEC 60092-350, 353, 354, 376
EEaarrtthhiinngg && BBoonnddiinngg wwiirree
0.6/1kV UX
0.6/1kV RX 47 ~ 48
EEaarrtthhiinngg && BBoonnddiinngg wwiirree
0.6/1kV UX, RX
- Design guide : NEK-606 & IEC 60092-353
- Flame retardant : IEC 60332-1 &
IEC 60332-3 Category A
- Halogen content : IEC 60754-1, 0.5%
- Cold bend / impact : CSA 22.2 No.03 (-40 /-35 )
- Smoke light transmittance : IEC 61034, 60%
- Sunlight (UV) resistant : UL 1581
AAPPPPLLIICCAATTIIOONN SSTTAANNDDAARRDD
CCAABBLLEE DDEESSIIGGNNAATTIIOONN ((PP1155))
1. Conductor
2. InsulationRX
UX
-
Stranded tinned annealed copper wires as per IEC 60228, Class 2
EPR as per IEC 60092-351
SHF2 as per IEC 60092-359
Insulation color : Yellow/Green (Green base with yellow strip) or Green
CCOONNSSTTRRUUCCTTIIOONN Classification Code Construction detail
No. ofCores
ConductorNominal
AreaStrand Dia.
NO. mm2 No. / mm mm mm mm mm kg / km /km M /km
Thicknessof
InsulationNominal
Toler-ance
Overall diameter ConductorResistance
(at 20°C) (Max.)
Cable Weight
InsulationResistance
(at 20°C) (Min.)
0.6/
1KV
RX
48 Offshore Cable
1.0 7 / 0.43 1.29 1.0 4.8 0.5 38 18.2 201.5 7 / 0.53 1.59 1.0 5.1 0.5 46 12.2 182.5 7 / 0.67 2.01 1.0 5.6 0.5 59 7.56 16
4 7 / 0.85 2.55 1.0 6.2 0.5 79 4.70 146 7 / 1.04 3.12 1.0 6.7 0.6 101 3.110 12
10 7 / 1.35 4.05 1.0 7.7 0.6 150 1.840 1016 7 / 1.70 5.10 1.0 8.8 0.7 210 1.160 825 7 / 2.14 6.42 1.2 10.8 0.7 330 0.734 8
1 35 7 / 2.52 7.56 1.2 12.0 0.8 440 0.529 750 19 / 1.78 8.90 1.4 13.8 0.9 580 0.391 770 19 / 2.14 10.70 1.6 16.2 0.9 820 0.270 695 19 / 2.52 12.60 1.6 18.1 1.0 1,090 0.195 5
120 37 / 2.03 14.21 1.6 19.8 1.1 1,350 0.154 5150 37 / 2.25 15.75 1.8 21.9 1.2 1,650 0.126 5185 37 / 2.52 17.64 2.0 24.3 1.3 2,050 0.100 5240 61 / 2.25 20.25 2.2 27.5 1.4 2,670 0.0762 5300 61 / 2.52 22.68 2.4 30.5 1.5 3,320 0.0607 5
VVFFDD CCaabbllee LV P
ower
& L
ight
ing
Cabl
eIn
stru
men
tatio
n &
Com
mun
icat
ion
Cabl
eVF
D Ca
ble
Eart
hing
& B
ondi
ng w
ireHV
Pow
er C
able
Tech
nica
l Inf
orm
atio
n
NEK-606 (2004), IEC 60092-350, 353, 354, 376
0.6/1kV(1.8/3kV) RFOU(VFD)
0.6/1kV(1.8/3kV) BFOU(VFD)
49 ~ 51
52 ~ 52
50 Offshore Cable
VVFFDD CCaabbllee
0.6/1kV(1.8/3kV) RFOU(VFD]
- Design guide : NEK-606 & IEC 60092-353
- Flame retardant : IEC 60332-1 &
IEC 60332-3 Category A
- Halogen content : IEC 60754-1, 0.5%
- Cold bend / impact : CSA 22.2 No.03 (-40 /-35 )
- Mud resistant : NEK-606 (Mud type only)
- Smoke light transmittance : IEC 61034, 60%
- Sunlight (UV) resistant : UL 1581
AAPPPPLLIICCAATTIIOONN SSTTAANNDDAARRDD
CCAABBLLEE DDEESSIIGGNNAATTIIOONN
1. Conductor2. Insulation
3. Cabling
4. Inner covering
5. Armor (Screen)
6. Sheath
7. Core identification
R
F
(VFD)
O
U
Stranded tinned annealed copper wires as per IEC 60228, Class 2
EPR as per IEC 60092-351
- Insulated cores shall be cabled.
- Flame retardant & non-hygroscopic fillers may be used .
- Suitable tape(s) may be applied on the cabled core.
Flame retardant halogen free thermoset compound
CU/PS tape
- Braid of tinned copper wire
- Coverage density of braid shall be not less than 100%.
- A suitable separator tape(s) may be applied over the armor.
- SHF2 or SHF Mud as per IEC 60092-359
- Outer sheath color : Black
3C+3E : Black, White, Red + G/Y (Earth core)
CCOONNSSTTRRUUCCTTIIOONN Classification Code Construction detail
0.6/
1kV
(1.8
/3kV
) R
FO
U(V
FD
)
Note.Flexible cable (Class5 Conductor) can be supplied
3C 25 7 / 2.14 6.42 2.2 26.8 33.0 1.6 2,070 0.734 830
3E 6 7 / 1.04 3.12 1.0 3.110 790
3C 35 7 / 2.52 7.56 2.2 29.8 36.6 1.8 2,630 0.529 730
3E 6 7 / 1.04 3.12 1.0 3.110 790
3C 50 19 / 1.78 8.90 2.2 32.8 39.8 1.9 3,270 0.391 640
3E 10 7 / ,1.35 4.05 1.0 1.840 640
3C 70 19 / 2.14 10.70 2.2 36.7 44.1 2.1 4,300 0.270 550
3E 16 7 / 1.70 5.10 1.0 1.160 530
3C 95 19 / 2.52 12.60 2.4 42.0 49.8 2.3 5,490 0.195 510
3E 16 7 / 1.70 5.10 1.0 1.160 530
3C 120 37 / 2.03 14.21 2.4 45.5 53.5 2.4 6,690 0.154 460
3E 25 7 / 2.14 6.42 1.2 0.734 510
3C 150 37 / 2.25 15.75 2.4 49.3 57.7 2.6 7,800 0.126 420
3E 25 7 / 2.14 6.42 1.2 0.734 510
3C 185 37 / 2.52 17.64 2.4 53.4 62.0 2.8 9,420 0.100 380
3E 35 7 / 2.52 7.56 1.2 0.529 440
3C 240 61 / 2.25 20.25 2.4 59.0 68.2 3.0 11,900 0.076 340
3E 50 19 / 1.78 8.90 1.4 0.391 440
CCAABBLLEE TTYYPPEE :: 00..66//11kkVV((11..88//33kkVV)) RRFFOOUU((VVFFDD))No. ofCores
ConductorNominal
AreaStrand Dia.
No. mm2 No. / mm mm mm mm mm mm kg / km /km M /km
Thicknessof
Insulation
Nominaldia.
innercovering
Nominal Tolerance
Overall diameter ConductorResistance
(at 20°C) (Max.)
Cable WeightApprox.
InsulationResistance
(at 20°C) (Min.)
51Offshore Cable
LV P
ower
& L
ight
ing
Cabl
eIn
stru
men
tatio
n &
Com
mun
icat
ion
Cabl
eVF
D Ca
ble
Earth
ing
& Bo
ndin
g w
ireHV
Pow
er C
able
Tech
nica
l Inf
orm
atio
n
NEK-606 (2004), IEC 60092-350, 353, 354, 376
52 Offshore Cable
VVFFDD CCaabbllee
0.6/1kV(1.8/3kV) BFOU(VFD)
- Design guide : NEK-606 & IEC 60092-353
- Flame retardant : IEC 60332-1 &
IEC 60332-3 Category A
- Fire resistance : IEC 60331-21, 31
- Halogen content : IEC 60754-1, 0.5%
- Cold bend / impact : CSA 22.2 No.03 (-40 /-35 )
- Mud resistant : NEK-606 (Mud type only)
- Smoke light transmittance : IEC 61034, 60%
- Sunlight (UV) resistant : UL 1581
AAPPPPLLIICCAATTIIOONN SSTTAANNDDAARRDD
CCAABBLLEE DDEESSIIGGNNAATTIIOONN
1. Conductor2. Fire resisting layer3. Insulation
4. Cabling
5. Inner covering
6. Armor (Screen)
7. Sheath
8. Core identification
B
F
(VFD)
O
U
Stranded tinned annealed copper wires as per IEC 60228, Class 2
Mica/glass tape
EPR as per IEC 60092-351
- Insulated cores shall be cabled.
- Flame retardant & non-hygroscopic fillers may be used .
- Suitable tape(s) may be applied on the cabled core.
Flame retardant halogen free thermoset compound
CU/PS tape
- Braid of tinned copper wire
- Coverage density of braid shall be not less than 100%
- A suitable separator tape(s) may be applied over the armor.
- SHF2 or SHF Mud as per IEC 60092-359
- Outer sheath color : Black
3C+3E : Black, White, Red + G/Y (Earth core)
CCOONNSSTTRRUUCCTTIIOONN Classification Code Construction detail
0.6/
1kV
(1.8
/3kV
) B
FO
U(V
FD
)
Note.Flexible cable (Class5 Conductor) can be supplied
53Offshore Cable
LV P
ower
& L
ight
ing
Cabl
eIn
stru
men
tatio
n &
Com
mun
icat
ion
Cabl
eVF
D Ca
ble
Earth
ing
& Bo
ndin
g w
ireHV
Pow
er C
able
Tech
nica
l Inf
orm
atio
n
3C 25 7 / 2.14 6.42 2.2 25.7 31.7 1.6 1,970 0.734 830
3E 6 7 / 1.04 3.12 1.0 3.110 790
3C 35 7 / 2.52 7.56 2.2 28.7 34.9 1.7 2,420 0.529 730
3E 6 7 / 1.04 3.12 1.0 3.110 790
3C 50 19 / 1.78 8.90 2.2 31.5 38.5 1.8 3,160 0.391 640
3E 10 7 / 1.35 4.05 1.0 1.840 640
3C 70 19 / 2.14 10.70 2.2 35.4 42.6 2.0 4,150 0.270 550
3E 16 7 / 1.70 5.10 1.0 1.160 530
3C 95 19 / 2.52 12.60 2.4 40.7 48.3 2.2 5,330 0.195 510
3E 16 7 / 1.70 5.10 1.0 1.160 530
3C 120 37 / 2.03 14.21 2.4 44.2 52.2 2.4 6,540 0.154 460
3E 25 7 / 2.14 6.42 1.2 0.734 510
3C 150 37 / 2.25 15.75 2.4 47.6 55.8 2.5 7,590 0.126 420
3E 25 7 / 2.14 6.42 1.2 0.734 510
3C 185 37 / 2.52 17.64 2.4 51.9 60.5 2.7 9.230 0.100 380
3E 35 7 / 2.52 7.56 1.2 0.529 440
3C 240 61 / 2.25 20.25 2.4 57.7 66.7 3.0 11.690 0.076 340
3E 50 19 / 1.78 8.90 1.4 0.391 440
CCAABBLLEE TTYYPPEE :: 00..66//11kkVV((11..88//33kkVV)) BBFFOOUU((VVFFDD))No. ofCores
ConductorNominal
AreaStrand Dia.
No. mm2 No. / mm mm mm mm mm mm kg / km /km M /km
Thicknessof
Insulation
Nominaldia.
innercovering
Nominal Tolerance
Overall diameter ConductorResistance
(at 20°C) (Max.)
Cable Weight
InsulationResistance
(at 20°C) (Min.)
NEK-606 (2004), IEC 60092-350, 353, 354, 376
54 Offshore Cable
1. ELECTRICAL DATA2. VOLTAGE RATING SELECTION
3. TEST METHODS & EQUIPMENT4. INSTALLATION RECOMMENDATIONS
5. CORE IDENTIFICATION
TTeecchhnniiccaall IInnffoorrmmaattiioonn
LV P
ower
& L
ight
ing
Cabl
eIn
stru
men
tatio
n &
Com
mun
icat
ion
Cabl
eVF
D Ca
ble
Earth
ing
& Bo
ndin
g w
ireHV
Pow
er C
able
Tech
nica
l Inf
orm
atio
n
1. Current rating for continuous
0.751.01.52.5
46
10162535507095
120150185240300
1417213040517195
125155190240290340385440520590
1113182534436081
105135165200249288331177444511
101215212936506789
105135170205240270305365415
Nominal cross-sectional Areamm2 Single core Two core Three core & four core
NNOOTTEESS))
1. Maximum permissible service temperature of the conductor is 902. The current ratings given above are based on an ambient air temperature of 453. The current ratings given above are for 6 cables of less bunched or laid together in flat formation.
When more than 6 cables are bunched or laid close together, the current ratings given above should be multiplied correction factor 0.85.In case of cables not being loaded simultaneously, consideration of the actual loading appertaining is permitted
4. For cables with more than 4 core cables, the current ratings are given by the Formula;
Where, I1 : Current for single core cable
N : Number of coresI =
I1
N3
579
1214161924303744
109877766555
121110
99887766
181614131212111010
98
No. of cores 1.5mm2 (A)1.0 mm2 (A) 2.5mm2 (A)
35 40 45 50 55 60 65 70 75 8090 1.10 1.05 1.00 0.94 0.88 0.82 0.74 0.67 0.58 0.47
Maximum conductortemperature Correction factors for various ambient air temperature
ELECTRICAL DATA
55Offshore Cable
NEK-606 (2004), IEC 60092-350, 353, 354, 376
56 Offshore Cable
TTeecchhnniiccaall IInnffoorrmmaattiioonn
CABLE TYPE : 3.6/6kV RFOU, 3.6/6kV RFCU, 3.6/6kV RFBU
2. Capacitance, Inductance, Reactance, Impedance Data
CapacitanceC
CapacitanceC
mm2 /km mH / km /km /km /km /km /km mH / km /km /km /km /km10 0.247 0.458 0.144 0.173 2.351 2.353 0.247 0.324 0.102 0.122 2.348 2.34916 0.284 0.434 0.136 0.164 1.485 1.488 0.284 0.306 0.096 0.115 1.482 1.48425 0.328 0.409 0.128 0.154 0.945 0.949 0.328 0.290 0.091 0.109 0.940 0.94235 0.362 0.393 0.123 0.148 0.686 0.691 0.362 0.281 0.088 0.106 0.680 0.68350 0.408 0.375 0.118 0.142 0.512 0.518 0.408 0.270 0.085 0.102 0.506 0.50970 0.466 0.358 0.112 0.135 0.362 0.370 0.466 0.260 0.082 0.098 0.354 0.35895 0.528 0.343 0.108 0.129 0.273 0.282 0.528 0.252 0.079 0.095 0.263 0.268
120 0.581 0.332 0.104 0.125 0.224 0.234 0.581 0.246 0.077 0.093 0.213 0.219150 0.624 0.326 0.102 0.123 0.193 0.205 0.624 0.242 0.076 0.091 0.181 0.187185 0.695 0.317 0.099 0.119 0.165 0.177 0.695 0.237 0.074 0.089 0.151 0.159240 0.742 0.310 0.097 0.117 0.140 0.154 0.742 0.234 0.073 0.088 0.125 0.134300 0.770 0.305 0.096 0.115 0.126 0.141 - - - - - -
NominalArea
Single core cable Multi core cableInductance
LInductance
LReactance
X50 Hz
ReactanceX
50 Hz
ReactanceX
60 Hz
ReactanceX
60 Hz
ImpedanceZ
50 Hz
ImpedanceZ
50 Hz
ImpedanceZ
60 Hz
ImpedanceZ
60 Hz
CapacitanceC
CapacitanceC
mm2 /km mH / km /km /km /km /km /km mH / km /km /km /km /km16 0.288 0.450 0.141 0.170 1.486 1.489 0.288 0.335 0.105 0.126 1.483 1.48425 0.261 0.425 0.134 0.160 0.945 0.950 0.261 0.316 0.099 0.119 0.941 0.94335 0.278 0.407 0.128 0.153 0.687 0.692 0.287 0.305 0.096 0.115 0.681 0.68450 0.321 0.390 0.123 0.147 0.513 0.520 0.321 0.292 0.092 0.110 0.507 0.51170 0.365 0.370 0.116 0.140 0.363 0.371 0.365 0.280 0.088 0.106 0.355 0.36095 0.411 0.355 0.111 0.134 0.275 0.284 0.411 0.270 0.085 0.102 0.265 0.271
120 0.450 0.346 0.109 0.130 0.226 0.237 0.450 0.263 0.083 0.099 0.215 0.222150 0.484 0.337 0.106 0.127 0.195 0.207 0.484 0.258 0.081 0.097 0.183 0.190185 0.535 0.330 0.104 0.124 0.167 0.181 0.535 0.251 0.079 0.095 0.153 0.162240 0.591 0.321 0.101 0.121 0.143 0.158 0.591 0.245 0.077 0.092 0.127 0.137300 0.651 0.311 0.098 0.117 0.128 0.143 - - - - - -
NominalArea
Single core cable Multi core cableInductance
LInductance
LReactance
X50 Hz
ReactanceX
50 Hz
ReactanceX
60 Hz
ReactanceX
60 Hz
ImpedanceZ
50 Hz
ImpedanceZ
50 Hz
ImpedanceZ
60 Hz
ImpedanceZ
60 Hz
CABLE TYPE : 6/10kV RFOU, 6/10kV RFCU, 6/10kV RFBU
CapacitanceC
CapacitanceC
mm2 /km mH / km /km /km /km /km /km mH / km /km /km /km /km
NominalArea
Single core cable Multi core cableInductance
LInductance
LReactance
X50 Hz
ReactanceX
50 Hz
ReactanceX
60 Hz
ReactanceX
60 Hz
ImpedanceZ
50 Hz
ImpedanceZ
50 Hz
ImpedanceZ
60 Hz
ImpedanceZ
60 Hz
CABLE TYPE : 8.7/15kV RFOU, 8.7/15kV RFCU, 8.7/15kV RFBU
25 215 0.443 0.139 0.167 0.946 0.951 0.215 0.344 0.108 0.130 0.942 0.94535 0.235 0.424 0.133 0.160 0.688 0.693 0.235 0.330 0.104 0.125 0.682 0.68650 0.261 0.406 0.128 0.153 0.515 0.522 0.261 0.316 0.099 0.119 0.508 0.51370 0.295 0.386 0.121 0.145 0.365 0.374 0.295 0.302 0.095 0.114 0.357 0.36395 0.330 0.371 0.117 0.140 0.277 0.288 0.330 0.290 0.091 0.109 0.267 0.274
120 0.360 0.362 0.114 0.137 0.229 0.241 0.360 0.281 0.088 0.106 0.217 0.225150 0.386 0.353 0.111 0.133 0.198 0.211 0.386 0.275 0.086 0.104 0.185 0.194185 0.424 0.341 0.107 0.129 0.169 0.184 0.424 0.267 0.084 0.101 0.156 0.166240 0.468 0.332 0.104 0.125 0.145 0.161 0.468 0.260 0.082 0.098 0.130 0.144300 0.514 0.324 0.102 0.122 0.131 0.147 - - - - - -
57Offshore Cable
LV P
ower
& L
ight
ing
Cabl
eIn
stru
men
tatio
n &
Com
mun
icat
ion
Cabl
eVF
D Ca
ble
Earth
ing
& Bo
ndin
g w
ireHV
Pow
er C
able
Tech
nica
l Inf
orm
atio
n
CABLE TYPE : 0.6/1kV(1.8/3kV) RFOU(VFD)
CapacitanceC
InductanceL
ReactanceX
50 Hz
ReactanceX
60 HzNo. mm2 /km mH / km /km /km /km /km
No. ofCores
NominalArea
Multi core cable
ImpedanceZ
50 Hz
ImpedanceZ
60 Hz
CapacitanceC
CapacitanceC
mm2 /km mH / km /km /km /km /km /km mH / km /km /km /km /km
NominalArea
Single core cable ) Multi core cableInductance
LInductance
LReactance
X50 Hz
ReactanceX
50 Hz
ReactanceX
60 Hz
ReactanceX
60 Hz
ImpedanceZ
50 Hz
ImpedanceZ
50 Hz
ImpedanceZ
60 Hz
ImpedanceZ
60 Hz
CABLE TYPE : 0.6/1kV RFOU, 0.6/1kV RFCU, 0.6/1kV RFBU
1.5 0.204 0.564 0.177 0.213 15.557 15.558 0.305 0.358 0.112 0.135 15.557 15.5572.5 0.242 0.525 0.165 0.198 9.641 9.642 0.345 0.331 0.104 0.125 9.640 9.6414 0.283 0.488 0.153 0.184 5.995 5.996 0.379 0.311 0.098 0.117 5.994 5.9946 0.339 0.460 0.144 0.173 3.968 3.969 0.435 0.291 0.091 0.110 3.967 3.967
10 0.407 0.423 0.133 0.160 2.350 2.352 0.477 0.274 0.086 0.103 2.348 2.34816 0.504 0.392 0.123 0.148 1.484 1.486 0.500 0.258 0.081 0.097 1.481 1.48225 0.510 0.373 0.119 0.140 0.943 0.946 0.589 0.256 0.080 0.097 0.939 0.94135 0.575 0.356 0.112 0.134 0.684 0.688 0.685 0.249 0.078 0.094 0.679 0.68150 0.591 0.342 0.108 0.129 0.510 0.515 0.705 0.247 0.078 0.093 0.505 0.50770 0.685 0.325 0.102 0.123 0.359 0.365 0.715 0.238 0.075 0.090 0.352 0.35695 0.716 0.315 0.099 0.119 0.270 0.278 0.770 0.236 0.074 0.089 0.262 0.266
120 0.800 0.306 0.096 0.115 0.220 0.229 0.834 0.231 0.073 0.087 0.211 0.217150 0.800 0.306 0.096 0.115 0.220 0.229 0.834 0.231 0.073 0.087 0.211 0.217185 0.805 0.294 0.092 0.111 0.161 0.172 0.834 0.231 0.073 0.087 0.150 0.158240 0.822 0.289 0.091 0.109 0.136 0.149 0.848 0.230 0.072 0.087 0.124 0.133300 0.849 0.288 0.091 0.109 0.122 0.136 0.848 0.229 0.072 0.086 0.109 0.119
3C 95 0.582 0.255 0.080 0.096 0.264 0.2693E 163C 120 0.667 0.249 0.078 0.094 0.213 0.2193E 253C 150 0.715 0.244 0.077 0.092 0.181 0.1593E 253C 185 0.736 0.238 0.075 0.090 0.151 0.1593E 353C 240 0.794 0.233 0.073 0.088 0.125 0.1343E 50
CABLE TYPE : 0.6/1kV(1.8/3kV) BFOU(VFD)
CapacitanceC
InductanceL
ReactanceX
50 Hz
ReactanceX
60 HzNo. mm2 /km mH / km /km /km /km /km
No. ofCores
NominalArea
Multi core cable
ImpedanceZ
50 Hz
ImpedanceZ
60 Hz
3C 95 0.550 0.262 0.082 0.099 0.264 0.2703E 163C 120 0.603 0.255 0.080 0.096 0.214 0.2203E 253C 150 0.658 0.250 0.079 0.094 0.182 0.1893E 253C 185 0.715 0.244 0.077 0.092 0.152 0.1603E 353C 240 0.770 0.238 0.075 0.090 0.126 0.1353E 50
* Reactance for 1-conductor cables given at Three-foil formation
NEK-606 (2004), IEC 60092-350, 353, 354, 376
58 Offshore Cable
TTeecchhnniiccaall IInnffoorrmmaattiioonn
CapacitanceC
CapacitanceC
mm2 /km mH / km /km /km /km /km /km mH / km /km /km /km /km
NominalArea
Single core cable ) Multi core cableInductance
LInductance
LReactance
X50 Hz
ReactanceX
50 Hz
ReactanceX
60 Hz
ReactanceX
60 Hz
ImpedanceZ
50 Hz
ImpedanceZ
50 Hz
ImpedanceZ
60 Hz
ImpedanceZ
60 Hz
CABLE TYPE : 0.6/1kV BFOU, 0.6/1kV BFCU, 0.6/1kV BFBU
CABLE TYPE : 250V Instrument & communication cables.
1.5 0.172 0.575 0.181 0.217 15.557 15.558 0.278 0.388 0.122 0.146 15.557 15.557
2.5 0.201 0.539 0.168 0.203 9.641 9.642 0.309 0.359 0.113 0.135 9.640 9.641
4 0.234 0.502 0.158 0.189 5.995 5.996 0.345 0.335 0.105 0.126 5.994 5.994
6 0.277 0.469 0.147 0.177 3.968 3.970 0.385 0.313 0.098 0.118 3.967 3.967
10 0.331 0.432 0.136 0.163 2.350 2.352 0.435 0.292 0.092 0.110 2.348 2.349
16 0.405 0.403 0.127 0.152 1.485 1.487 0.500 0.274 0.086 0.103 1.482 1.483
25 0.437 0.381 0.120 0.144 0.944 0.947 0.527 0.267 0.084 0.101 0.940 0.941
35 0.493 0.362 0.114 0.137 0.684 0.688 0.556 0.258 0.081 0.097 0.679 0.682
50 0.515 0.350 0.110 0.132 0.511 0.516 0.589 0.255 0.080 0.096 0.505 0.508
70 0.604 0.330 0.104 0.124 0.360 0.366 0.695 0.245 0.077 0.092 0.353 0.356
95 0.632 0.319 0.100 0.120 0.270 0.278 0.715 0.243 0.076 0.091 0.262 0.267
120 0.705 0.309 0.097 0.117 0.221 0.230 0.758 0.237 0.074 0.089 0.212 0.218
150 0.698 0.305 0.096 0.115 0.190 0.200 0.758 0.237 0.075 0.089 0.180 0.187
185 0.725 0.299 0.094 0.113 0.161 0.173 0.782 0.236 0.074 0.089 0.151 0.159
245 0.749 0.294 0.092 0.111 0.137 0.150 0.807 0.234 0.073 0.088 0.125 0.134
300 0.778 0.291 0.091 0.110 0.123 0.137 0.820 0.232 0.073 0.088 0.110 0.120
* Reactance for 1-conductor cables given at Three-for foil formation
Size unit 0.75mm2 1.0mm2 1.5mm2 2.5mm2
nF/km 100 100 120 120
nF/km 80 80 90 90
mH/km 0.75 0.73 0.68 0.68
Mutualcapacitance
Inductance
Individual screen
Collective screen
Inductance & Reactance Data
59Offshore Cable
LV P
ower
& L
ight
ing
Cabl
eIn
stru
men
tatio
n &
Com
mun
icat
ion
Cabl
eVF
D Ca
ble
Earth
ing
& Bo
ndin
g w
ireHV
Pow
er C
able
Tech
nica
l Inf
orm
atio
n
3. Short circuit current rating
The short circuit currents quoted here are for cables operating normally at maximum conductor temperature of85 . EPR insulation is actually capable of withstanding short-term Temperature up to 250
According to ICEA P-32-382 Curves based on formula
Nominalarea
mm2
Short circuit currents (kA)
Duration of short circuit in second
1.5 1.3 1.0 0.8 0.7 0.6 0.5 0.4 0.3 0.3 0.3 0.3 0.2 0.2 0.2
2.5 2.0 1.6 1.3 1.1 0.9 0.8 0.6 0.6 0.5 0.5 0.4 0.4 0.4 0.3
4 3.2 2.5 2.1 1.8 1.5 1.3 1.0 0.9 0.8 0.7 0.7 0.6 0.6 0.6
6 4.9 3.8 3.2 2.7 2.3 1.9 1.5 1.3 1.2 1.1 1.0 0.9 0.9 0.8
10 8.2 6.3 5.4 4.5 3.8 3.2 2.6 2.2 2.0 1.8 1.7 1.6 1.5 1.4
16 13.0 10.1 8.5 7.1 6.0 5.0 4.1 3.6 3.2 2.9 2.7 2.5 2.4 2.2
25 20.6 15.9 13.5 11.3 9.5 8.0 6.5 5.6 5.0 4.6 4.3 4.0 3.8 3.6
35 28.5 22.1 18.7 15.6 13.2 11.1 9.0 7.8 7.0 6.4 5.9 5.5 5.2 4.9
50 38.6 29.9 25.3 21.2 17.9 15.0 12.2 10.6 9.5 8.6 8.0 7.5 7.1 6.7
70 55.9 43.3 36.6 30.6 25.9 21.6 17.7 15.3 13.7 12.5 11.6 10.8 10.2 9.7
95 77.5 60.0 50.7 42.4 35.9 30.0 24.5 21.2 19.0 17.3 16.0 15.0 14.1 13.4
150 97.9 75.8 64.1 53.6 45.3 37.9 31.0 26.8 24.0 21.9 20.3 19.0 17.9 17.0
150 120.3 93.1 78.7 65.9 55.7 46.6 38.0 32.9 29.5 26.9 24.9 23.3 22.0 20.8
185 150.8 116.8 98.8 82.6 69.8 58.4 47.7 41.3 36.9 33.7 31.2 29.2 27.5 26.1
240 198.3 153.6 129.8 108.6 91.8 76.8 62.7 54.3 48.6 44.3 41.0 38.4 36.2 34.3
300 248.7 192.6 162.8 136.2 115.1 96.3 78.6 68.1 60.9 55.6 51.5 48.2 45.4 43.1
400 329.3 255.1 215.6 180.4 152.5 127.6 104.1 90.2 80.7 73.6 68.2 63.8 60.1 57.0
500 401.0 310.6 262.5 219.6 185.6 155.3 126.8 109.8 98.2 89.7 83.0 77.7 73.2 69.5
0.03 0.05 0.07 0.1 0.14 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
T1 = 90, T2 = 250
NEK-606 (2004), IEC 60092-350, 353, 354, 376
Where s : Short Circuit Current (kA)A : Conductor area ( )T1 : Operating temperature ( 85 )
T2 : Short Circuit temperature ( 250 )
t : Short Circuit duration (sec)
Is = A x 0.115 log
t
(T2 + 234)(T1 + 234)
60 Offshore Cable
TTeecchhnniiccaall IInnffoorrmmaattiioonn
4. Voltage drop
CABLE TYPE : 3.6/6kV RFOU. 3.6/6kV RFCU, 3.6/6kV RFBU
Calculate fomula
Voltage drop coefficient
10 1.840 2.346 2.346 1.00 0.97 0.93 0.89 0.84 0.80 0.7516 1.160 1.479 1.479 1.00 0.98 0.95 0.91 0.87 0.82 0.7825 0.734 0.936 0.936 1.00 1.00 0.97 0.94 0.90 0.86 0.8235 0.529 0.675 0.675 1.00 1.02 1.00 0.97 0.93 0.90 0.8650 0.391 0.499 0.499 1.00 1.04 1.02 1.00 0.97 0.94 0.9070 0.270 0.344 0.344 1.00 1.07 1.07 1.06 1.04 1.01 0.9895 0.195 0.249 0.251 1.00 1.11 1.12 1.12 1.11 1.09 1.07
120 0.154 0.196 0.198 1.00 1.15 1.17 1.18 1.18 1.17 1.15150 0.126 0.161 0.164 1.00 1.18 1.23 1.25 1.25 1.25 1.24185 0.100 0.128 0.131 1.00 1.23 1.30 1.33 1.35 1.35 1.35240 0.0762 0.0972 0.1010 1.00 1.31 1.40 1.46 1.49 1.51 1.53
mm2 /km /km /km 100% 95% 90% 85% 80% 75% 70%
NominalArea
R-dc(at 20 )
R-dc(at 90 )
R-ac(at 90 )
Inductive voltage drop coefficient
Dielectric power factor (at at 60HZ & 90 Conductor temperature)
CABLE TYPE : 6/10kV RFOU, 6/10kV RFCU, 6/10kV RFBU
16 1.160 1.479 1.479 1.00 0.99 0.95 0.91 0.87 0.83 0.7825 0.734 0.936 0.936 1.00 1.00 0.97 0.94 0.90 0.86 0.8235 0.529 0.675 0.675 1.00 1.02 1.00 0.97 0.94 0.90 0.8650 0.391 0.499 0.499 1.00 1.04 1.03 1.01 0.98 0.95 0.9170 0.270 0.344 0.344 1.00 1.08 1.08 1.06 1.04 1.02 0.9995 0.195 0.249 0.251 1.00 1.12 1.13 1.13 1.12 1.10 1.08
120 0.154 0.196 0.198 1.00 1.16 1.19 1.20 1.19 1.19 1.17150 0.126 0.161 0.164 1.00 1.19 1.24 1.26 1.27 1.26 1.25185 0.100 0.128 0.131 1.00 1.25 1.31 1.35 1.37 1.38 1.38240 0.0762 0.0972 0.1010 1.00 1.32 1.42 1.48 1.52 1.54 1.55
mm2 /km /km /km 100% 95% 90% 85% 80% 75% 70%
NominalArea
R-dc(at 20 )
R-dc(at 90 )
R-ac(at 90 )
Inductive voltage drop coefficient
Dielectric power factor (at at 60HZ & 90 Conductor temperature)
CABLE TYPE : 6/10kV RFOU, 6/10kV RFCU, 6/10kV RFBU
25 0.734 0.936 0.936 1.00 1.01 0.98 0.94 0.91 0.87 0.8335 0.529 0.675 0.675 1.00 1.02 1.00 0.97 0.94 0.91 0.8750 0.391 0.499 0.499 1.00 1.05 1.03 0.01 0.98 0.95 0.9270 0.270 0.344 0.344 1.00 1.08 1.08 1.07 1.05 1.03 1.0095 0.195 0.249 0.251 1.00 1.12 1.14 1.14 1.13 1.12 1.10
120 0.154 0.196 0.198 1.00 1.17 1.20 1.21 1.21 1.21 1.19150 0.126 0.161 0.164 1.00 1.20 1.25 1.28 1.29 1.29 1.28185 0.100 0.128 0.131 1.00 1.26 1.33 1.37 1.39 1.40 1.40240 0.0762 0.0972 0.1010 1.00 1.34 1.44 1.50 1.54 1.57 1.58
mm2 /km /km /km 100% 95% 90% 85% 80% 75% 70%
NominalArea
R-dc(at 20 )
R-dc(at 90 )
R-ac(at 90 )
Inductive voltage drop coefficient
Dielectric power factor (at at 60HZ & 90 Conductor temperature)
1) D.C. circuit
2) A.C. circuit
Where L : Cable length (km) I : Current(A) V : Circuit Voltage(V)Rdc : D.C. resistance at maximum rated
conductor temperature (see following table)
Rac : A.C. resistance at maximum ratedconductor temperature (see following table)
: Inductive voltage drop coefficient
Voltage drop rate =
Voltage drop rate of single-phase A.C.=
Rdc x 2L x IV
x 100(%)
x x 100(%)Rac x 2L x IV
Voltage drop rate of three-phase A.C.= x x 100(%)x Rac x 2L x I 3
2V
61Offshore Cable
LV P
ower
& L
ight
ing
Cabl
eIn
stru
men
tatio
n &
Com
mun
icat
ion
Cabl
eVF
D Ca
ble
Earth
ing
& Bo
ndin
g w
ireHV
Pow
er C
able
Tech
nica
l Inf
orm
atio
n
CABLE TYPE : 0.6/1kV RFOU, 0.6/1kV RFCU, 0.6/1kV RFBU
1.5 12.2 15.6 15.6 1.00 0.95 0.91 0.86 0.81 0.76 0.71
2.5 7.56 9.64 9.64 1.00 0.96 0.91 0.86 0.81 0.76 0.71
4 4.70 5399 5.99 1.00 0.96 0.91 0.87 0.82 0.77 0.72
6 3.11 3.97 3.97 1.00 0.96 0.92 0.87 0.83 0.78 0.73
10 1.84 2.35 2.35 1.00 0.97 0.93 0.89 0.84 0.80 0.75
16 1.16 1.48 1.48 1.00 0.98 0.94 0.90 0.86 0.82 0.77
25 0.734 0.936 0.936 1.00 1.00 0.97 0.93 0.89 0.85 0.81
35 0.529 0.675 0.675 1.00 1.01 0.99 0.95 0.92 0.88 0.84
50 0.391 0.499 0.499 1.00 1.03 1.01 0.99 0.96 0.92 0.88
70 0.270 0.344 0.344 1.00 10.6 1.06 1.04 1.01 0.99 0.95
95 0.195 0.249 0.251 1.00 1.10 1.11 1.10 1.08 1.06 1.04
120 0.154 0.196 0.198 1.00 1.13 1.15 1.16 1.15 1.13 1.11
150 0.126 0.161 0.164 1.00 1.17 1.20 1.21 1.21 1.21 1.19
185 0.100 0.128 1.131 1.00 1.21 1.27 1.29 1.31 1.31 1.30
240 0.0762 0.0972 0.1010 1.00 1.29 1.37 1.42 1.45 1.46 1.47
300 0.0607 0.0774 0.0820 1.00 1.36 1.48 1.55 1.59 1.63 1.65
mm2 /km /km /km 100% 95% 90% 85% 80% 75% 70%
NominalArea
R-dc(at 20 )
R-dc(at 90 )
R-ac(at 90 )
Inductive voltage drop coefficient
Dielectric power factor (at 60Hz & 90 )
CABLE TYPE : 0.6/1kV BFOU, 0.6/1kV BFCU, 0.6/1kV BFBU
1.5 12.2 15.6 15.6 1.00 0.95 0.91 0.86 0.81 0.76 0.71
2.5 7.56 9.64 9.64 1.00 0.96 0.91 0.86 0.81 0.76 0.72
4 4.70 5.99 5.99 1.00 0.96 0.91 0.87 0.82 0.77 0.72
6 3.11 3.97 3.97 1.00 0.96 0.92 0.87 0.83 0.78 0.73
10 1.84 2.35 2.35 1.00 0.97 0.93 0.89 0.84 0.80 0.75
16 1.16 1.48 1.48 1.00 0.98 0.94 0.90 0.86 0.82 0.77
25 0.734 0.936 0.936 1.00 1.00 0.97 0.93 0.89 0.85 0.81
35 0.529 0.675 0.675 1.00 1.01 0.99 0.96 0.92 0.88 0.84
50 0.391 0.499 0.499 1.00 1.03 1.02 0.99 0.96 0.92 0.89
70 0.270 0.344 0.344 1.00 1.06 1.06 1.04 1.02 0.99 0.96
95 0.195 0.249 0.251 1.00 1.10 1.11 1.10 1.09 1.07 1.04
120 0.154 0.196 0.198 1.00 1.13 1.16 1.16 1.15 1.14 1.12
150 0.126 0.161 0.164 1.00 1.17 1.21 1.22 1.22 1.21 1.20
185 0.100 0.128 0.131 1.00 1.22 1.27 1.30 1.31 1.32 1.31
240 0.0762 0.0972 0.1010 1.00 1.29 1.38 1.43 1.46 1.48 1.48
300 0.0607 0.0774 0.0820 1.00 1.37 1.48 1.55 1.60 1.63 1.65
mm2 /km /km /km 100% 95% 90% 85% 80% 75% 70%
NominalArea
R-dc(at 20 )
R-dc(at 90 )
R-ac(at 90 )
Inductive voltage drop coefficient
Dielectric power factor (at 60Hz)
NEK-606 (2004), IEC 60092-350, 353, 354, 376
62 Offshore Cable
TTeecchhnniiccaall IInnffoorrmmaattiioonn
VOLTAGE RATING SELECTION
NNoottee)) The rated voltage of the cable for a given application shall be suitable for the operating condition in the system in which the cableis used. To facilitate the choice of the cable, the system are divided into the following three categories
Category A : This category comprises those systems in which any phase conductor than comes in contact with earth or an earthconductor , is automatically disconnected from the system within 1 minute.
Category B : This category comprises those systems in which, under fault conditions, are operated for a short time, not exceeding8 hours on any occasion, faults in any year should not exceed 125 hours.
Category C : This category comprises all systems which do not fall into categories A and B.
Selection cable for A.C systems
A & B
C
A & B
C
A & B
C
A & B
C
C
Supplysystem
Supplycategory
System voltage (kV) Recommended (kV)
Phase to earth(Uo)
AboveUp to andincluding
Above Up to andincluding
Maximumsustained
voltage (Um)
Phase to phase(U)
IECstandard
UO / UUO / U
BS standards
- 0.15 - 0.25 0.28 0.15 / 0.25 0.15 / 0.250.15 0.6 0.25 1 1.2 0.6 / 1 0.6 / 1
- - - 0.15 - 0.15 / 0.25 0.15 / 0.25- - 0.15 0.6 - 0.6 / 1 0.6 / 1- 0.15 - 0.25 0.28 0.15 / 0.25 0.15 / 0.25
0.15 0.6 0.25 1 1.2 0.6 / 1 0.6 / 10.6 1.9 - 3.3 3.6 1.8 / 3 1.9 / 3.31.9 3.8 3.3 6.6 7.2 3.6 / 6 3.8 / 6.63.8 6.35 6.6 11 12 6 / 10 6.35 / 11
6.35 8.7 11 15 17 8.7 / 15 -8.7 12.7 15 22 24 12 / 20 12.7 / 22- - - 0.15 - 0.15 / 0.25 0.15 / 0.25- - 0.15 0.6 - 0.6 / 1 0.6 / 1- - 0.6 1.9 - 1.8 / 3 1.9 / 3.3- - 1.9 3.3 3.6 3.6 / 6 3.8 / 6.6- - 3.3 6.6 7.2 6 / 10 6.35 / 11- - 6.6 11 12 8.7 / 15 11 / 11- - 11 15 17.5 12 / 20 12.7 / 22- 0.15 - 0.21 - 0.15 / 0.25 0.15 / 0.25
0.15 0.6 - 0.84 - 0.6 / 1 0.6 / 1- - - 0.15 - 0.15 / 0.25 0.15 / 0.25- - 0.15 0.a6 - 0.6 / 1 0.6 / 1- - 0.6 1.9 - 1.8 / 3 1.9 / 3.3- 0.15 - 0.25 0.28 0.15 / 0.25 0.15 / 0.25
0.15 0.6 0.25 1 1.2 0.6 / 1 0.6 / 1- - - 0.15 - 0.15 /0.25 0.15 / 0.25- - 0.25 0.6 - 0.6 / 1 0.6 / 1- - - 0.15 - 0.15 /0.25 0.15 / 0.25- - 0.15 0.6 - 0.6 / 1 0.6 / 1- - 0.6 1.9 - 1.8 / 3 19. / 3.3- - 1.9 3.3 3.6 3.6 / 6 3.8 / 6.6- - 3.3 6.6 7.2 6 / 10 6.35 / 11- - 6.6 11 12 8.7 / 15 -- - 11 15 17.5 12 / 20 12.7 / 22
3-Phase 4-Wire
3-Phase 4-Wire
1-Phase 3-Wire
1-Phase 3-Wire
1-Phase 2-Wireor
1-Phase 1-Wire
2-Phase 3-Wireor 2-Phase 4-Wire
2-Phase 3-Wireor 2-Phase 4-Wire
3-Phase 3-Wire
3-Phase 3-Wire
63Offshore Cable
LV P
ower
& L
ight
ing
Cabl
eIn
stru
men
tatio
n &
Com
mun
icat
ion
Cabl
eVF
D Ca
ble
Earth
ing
& Bo
ndin
g w
ireHV
Pow
er C
able
Tech
nica
l Inf
orm
atio
n
TEST METHODS & TEST EQUIPMENT
1. Flame retardant test 2. Fire resistant test
3. Cold test (Bending / Impact) 4. Halogen content test
5. Smoke emission test 6. Oxygen index test
IEC 60332-3. CAT. A (VTFT)
CSA C22.2 No.03 (-40 -35
IEC 61034-1,2 Test
IEC 60754-1,2 Test
ASTM D 2863
IEC 60331 (at 750 1000 )
NEK-606 (2004), IEC 60092-350, 353, 354, 376
64 Offshore Cable
TTeecchhnniiccaall IInnffoorrmmaattiioonn
7. Mud resistant testMud resistant cables shall be designed with sheathing compounds suitable for installation and operation incontact with MUD unless otherwise specified. Type SHF Mud.
The variation in the tensile strength and elongation at break values from those values obtained on theunaged sample shell not exceed 25%.The volume swell and weight increase shell not exceed 20%and 15% respectively.
1) IRM 903 requirementsThe variation in the tensile strength and elongation at break values from those values obtained on the unaged sample shell not exceed 30%.
2) “Drilling fluid” mud test requirements for sheathing compound SHF mudTest shall be carried out on dumbbells as specified in IEC 60092-359 Table clause 3 except that the testfluids and conditions shall be as given in Table 1.
8. Oil resistanceAll thermoset sheathed cables shall be suitable for an oil production installation. The oil resistanceproperties shall be demonstrated by a test according to IEC 60092-359 Table clause 3, type SHF2.
Tesa fluid Temperature DurationMineral oil type-IRM 903 100 7d
Calcium Bromide Brine (Water based) 70 56d
Carbo Sea (oil based) 70 56d
65Offshore Cable
LV P
ower
& L
ight
ing
Cabl
eIn
stru
men
tatio
n &
Com
mun
icat
ion
Cabl
eVF
D Ca
ble
Earth
ing
& Bo
ndin
g w
ireHV
Pow
er C
able
Tech
nica
l Inf
orm
atio
n
The following installation recommendations are in accordance with IEC regulation and practice.Different regulations may apply in other countries.
1. Minimum cable bending radius
NNootteess)) D : Overall diameter of cable
The bending radius for the installation of cables should be not less than the values given as follows;
2. Installation temperature
Minimum recommended installation temperature for cables shall be -20
3. Pulling tension
The cable pulling tension during installation can be estimated by means of the following formula:
p=5kg x total cross section of conductors in the armoured cable or,p=2.5kg x total cross section of conductors in the unarmoured cable
Additional tension will be supplied from the braid and the insulation and sheathing compound.
INSTALLATION RECOMMENDATIONS
NEK-606 (2004), IEC 60092-350, 353, 354, 376
r
D
Type of cable Minimum bending radius
Up to1.8/3kV
3.6/6kVabove
Unarmored or unbraided
D 25mm 4 X D
D 25mm 6 X D
Metal braid screened or armored 6 X D
Tape screened 8 X D
Single core 12 X D
3-core 9 X D
66 Offshore Cable
TTeecchhnniiccaall IInnffoorrmmaattiioonn
4. Explosion risk areas
1) AreasThe areas on board are usually classified in two main categories with regards to the explosion risk :
Hazardous areas : Areas in which explosive gas-air mixtures are, or may be expected to be,present in quantities such as to require special precautions for the construction and use of electrical apparatus.
Safe areas(non-hazardous areas ) : Areas n which explosive gas-air mixtures are not expected to be,present in quantities such as to required special precautions for the construction and use of electricalapparatus.
A hazardous area is divided into three zones :Zone 0 : in which an explosive gas-air mixture is continuously present or present for long periods.
Zone 1 : in which an explosive gas-air mixture is likely to occur in normal operation
Zone 2 : in which an explosive gas-air mixture is not likely to occur, and if occurs it will only exist for a short time
2) Installation of cables
For cables to be used in zone 0 and zone 1, one of the following types of protection is required:A non-metallic outer sheath in combination with braiding or other metallic covering for earth fault detection and mechanical protection. A non-metallic outer sheath is, however, not required if the screen or armouring consists of a corrosion resistant bronze alloy.A lead sheathing in addition to further mechanical protection, for example armour braiding or non-metallic impervious sheath.For mineral insulated cables, a copper or stainless steel sheath.Single core cables in installations with A.C or D.C. current with a high ripple content should be of typeswithout screen of armouring. Where mechanical damage is possible, such cables should otherwise bemechanically protected or installed in ducts or similar.
For installations in zone 2, cables without screen or armour can be used.
67Offshore Cable
LV P
ower
& L
ight
ing
Cabl
eIn
stru
men
tatio
n &
Com
mun
icat
ion
Cabl
eVF
D Ca
ble
Earth
ing
& Bo
ndin
g w
ireHV
Pow
er C
able
Tech
nica
l Inf
orm
atio
n
5. Earthing of metal coverings of cables
1) General requirements
All metal coverings of cables, armouring or shielding shall be earthed. Earthing must be provided at bothends except for final sub-circuits where earthing at only one end(the supply end)is sufficient.Earthing at one end is permitted where it is required for technical or safety reasons, control andinstrumentation cables, mineral insulated cables, intrinsically safe circuits, control circuits etc.
Metal covering of single core cable for AC and single core cable for DC with ripple content exceeding 10%and having a current rating exceeding 20A is to be earthed at one and only.when sing;e core cables for AC and DC with ripple content higher than 10% are installed in or passingthrough hazardous areas, the metal screen or armour is to be earthed inside the hazardous area to avoiddangerous potential between screen armour and earthed part of the installation
2) Cross section of earth connections
Earth connections for metal coverings shall be carried out with conductors having cross sectional areasrelated to the cross sectional areas of the phase conductors and the current ratings of the cables, or atleast the same cross sectional areas as the metal covering itself.
3) Earthing through metal clamps etc.
Metal coverings of cables may be earthed through clamps. The clamps must grip the metal covering of thecable and must be connected to the hull and provide a good conductive connection between the metalcovering and the hull. The metal clamps must be corrosion resistant.
4) Earthing through cable glands
The metal coverings of cables may be earthed by means of glands intended for the purpose and sodesigned as to ensure an effective earth connection. The glands shall be firmly attached to, and ineffective electrical contact with, a metal structure earthed in accordance with these regulations.
5) Earthing of metal pipes, conduits etc.
Metal pipes and cable conduits are to be earthed. Pipes and conduits may be earthed by being screwedinto a metal enclosure, or by nuts in both sides of the wall of metallic enclosure, provided that the surfaceis clean and free from rust, scale or print.Comments : For intrinsically safe circuits it is important to separate the earth conductor from theprotective earthing. The resistance between a zener barrier earth and protective earth must be max.1ohm and preferably less than. 0.1ohm to avoid that possible fault current does not lead to a potentialincrease in the system.
NEK-606 (2004), IEC 60092-350, 353, 354, 376
68 Offshore Cable
TTeecchhnniiccaall IInnffoorrmmaattiioonn
6. Fixing of cables
Cables are to be suitably fixed to the supports. In order to guard against the effects ofelectrodynamics forces developing on the occurrence of a short circuit, single core cables shouldbe firmly fixed by using supports of a strength adequate to withstand forces corresponding to the values ofprospective short circuit current.The requirement concerning fixing can normally be fulfilled when the cables are clamped as follows:
For cables entering enclosures and conduits the nearest clamp is to be placed at a minimum distancefrom the entry of 10 times the diameter the cable concerned from the entry.At other points the distance between the clamps must not exceed the in the following table:
7. Mechanical protection of cables
Cables are to be installed in such a way that they are not subject to damaging mechanical stressed.where this can not be obtained the cables are to be protected. Unless the cable itself(for example armour orsheath) provides adequate protection the cables should be:
Enclosed in suitable conduits or casingscovered by steel pipes or profilesSteel pipes in which the cables are run
in areas where there is an exceptional risk of mechanical damage, for example in cargo hold area or differentstorage areas, the cables always have to be protected, even when the cables are armoured.The thickness of the protective conduits must be at least 4mm. The wall thickness of the protective conduit must be at least 2mm.Cables lay on aluminum supports may have a corresponding protection of aluminum. the thickness must be at least 4mm.Metal casing used for mechanical protection of cables should be efficiently protected against corrosion.
External diameter of cable (mm) Spacing of fixing points (mm)
Above Up to Cables with copper, bronzeor steel braid or armor
Cables without Metal braid or
armor
- 8 200 250
8 13 250 300
12 20 300 350
20 30 350 400
30 - 400 450
69Offshore Cable
LV P
ower
& L
ight
ing
Cabl
eIn
stru
men
tatio
n &
Com
mun
icat
ion
Cabl
eVF
D Ca
ble
Earth
ing
& Bo
ndin
g w
ireHV
Pow
er C
able
Tech
nica
l Inf
orm
atio
n
8. Installation of cables for fire propertiesCables must at least meet the flame retardant requirements. On board passenger ships, cargo-shipsand mobile offshore units, where requirements are considered to be satisfied if the cables havecharacteristics complying withe the cable bunch test IEC-Publication 60332-3, or fire stops are installed in accordance withthe following recommendations:When cable complying with single-cable test, but not the cable-bunch-test, are installed,fire stops are to be provided in enclosed or semi-enclosed spaces except for cargo rooms and tunnels in cargo areas.
a) For vertical cable runs- with a max. distance between fire stops of two decks or 6 meters, unless installed in totally enclosed cable ducts- at the main and emergency switchboard- where cables enter into an engine control room- at centralized control panels for propulsion machinery and essential auxiliaries- at the entrance to cables ducts
b) For horizontal cable runs.- Fire stops shall be as specified in item a) above but the maximum. distance between fire stops may be increased to 14m.
When choosing cable types special attention should be paid to reduce possible damage due to corrosion in case of a fire.Non-halogen free cables(materials)will give off corrosive gases during a fire.The corrosion effect depends on the amount of halogens in the materials used.Flame retardant cables are to give characteristics complying with the test requirements in IEC-Publication 60332-1, withamendments.Fire resistant cables are to give characteristics complying with the requirements in IEC-Publication 60331.
9. Intrinsically safe installationsCables and flexible cables for intrinsically safe circuits must have screen or similar of a conducting material and theouter sheath must be of an insulating material. A non-metallic outer sheath is, however, not required if the screen orarmour consists of a corrosion resistant bronze alloy. Where there is no danger of interference from the externalelectrical or magnetic fields, short flexible cables may be used without screen.
a) Associated equipmentAssociated equipment(e.g.power supply units) shall be situated in a safe area or has protection as mentioned in"Explosion risk areas."
b) Connection of equipmentWithin limitations laid down in 3., ordinary non-explosion protected equipment may be connected to intrinsically safeequipment, provided that it is designed to meet regulations in other respects.
c) Compliance with any limitations in the certificateWith intrinsically safe circuits special considerations must be given to ensure that the circuits characteristics(including connected equipment, cables, conductors etc.) satisfy any limitations in the test certificate.Such limitations may be maximum values for capacitance and inductance etc. It is pointed out there is a danger ofdamage to i.s equipment when using normal equipment for insulation testing
d) Adjacent locationConductors for i.s safe circuits and conductors for non-i.s safe circuits shall not be run together in the same cable,flexible cable, conduit, cables bunch etc.
e) Protection against electrical and magnetic fieldsWhere i.s circuits are exposed to magnetic or electrical field that may destroy the intrinsic safety of the system.Precautions must be taken during installation. Such precautions may be:- cables for i.s circuits and non-i.s circuits to be installed a minimum distance of 50mm apart.
The minimum distance to heavy current cables using D.C with a high ripple content should be 300mm.- cables for i.s circuits and non-i.s circuits to be separated panel of conducting material which is earthed.- cables for i.s circuits to have effective transposition.
f) MarkingThe marking may be a marking plate or by colour marking of the cables when using colour marking, the colour shouldbe light blue.
NEK-606 (2004), IEC 60092-350, 353, 354, 376
70 Offshore Cable
TTeecchhnniiccaall IInnffoorrmmaattiioonn
1. High voltage power cables
The individual cores shall be identified by the colored semi-conducting tape or colored ribbon tape runlongitudinally on the non-metallic part of insulation screening and the colour scheme shall be as follows:
1 core : Off-white (grey)3 core : Off-white (grey), Black, Red, or White, Red, Blue
2. Low voltage power and control cables
CORE IDENTIFICATION
The insulated cores shall be identified by the color of insulation or by the number printed on insulatedcores; as follows
1) NEK-606 standard
1core : Off-white(Grey) or Black2core : Off-white, Black3core : Off-white, Black, Red4core : Off-white, Black, Red, Blue or Black, Off-white, Red, Green.5core and above core: white number on black insulation or black number on white insulation
Earth core : Green/Yellow (green base with yellow tracer)
3. Instrumentation and communication cables
Each pair/triad shall be identified as follows.
- Pairs : Black, Light blue or Black, White- Triads : Black, Light blue, Brown or Black, White, Red
For identification of multi-pair/triad cables, pair/triad are identified by lapping of the numbered tape orby the number print directly on the each cores, and the number interval shall be 100mm or less.
The other color scheme may be applicable when purchaser required.
2) CENELEC harmonization document HD 308 S2
2C
3C
4C
5C
-
Green / Yellow
Green / Yellow
Green / Yellow
-
Blue
-
Blue
Brown
Brown
Brown
Black
Black
Grey
Grey
2C
3C
4C
5C
Blue
-
Blue
Blue
Brown
Brown
Brown
Brown
Black
Black
Black
Grey
Grey
Grey Black
71Offshore Cable
LV P
ower
& L
ight
ing
Cabl
eIn
stru
men
tatio
n &
Com
mun
icat
ion
Cabl
eVF
D Ca
ble
Earth
ing
& Bo
ndin
g w
ireHV
Pow
er C
able
Tech
nica
l Inf
orm
atio
n
NEK-606 (2004), IEC 60092-350, 353, 354, 376
Type approval certificates