Kevin BezoldSenior Product Manager
Teamcenter Integration for I-deas
5.1 and 6.0 Enhancements
© 2008. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM Software
Teamcenter Integration for I-deas 5.1
Teamcenter Integration for I-deas (TcII) 5.1� Released on November 15, 2007� Supports Teamcenter Engineering 2005 SR1 MP3� Supports NX I-deas 5m1
� Supports HP-UX, Sun Solaris and Windows XP Platforms
Enhancements
Page 2
© 2008. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM Software
Enhancements� HAM Medic Command
� Model File View Enhancements
� Absolute Occurrences
� Multiple Configurations� Hide and Suppress States� CGM Dataset Creation During Save to Teamcenter
� Configurable JT During Save to Teamcenter
� Purge Revisions of a Single Item
� Send Related Drawings to I-deas
� Send to I-deas from Right Mouse Button
� Local Language Error Messages
Teamcenter Integration for I-deas 5.1:HAM Medic Command
HAM Medic� Send to I-deas� Export Package File
Page 3
© 2008. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM Software
Teamcenter Integration for I-deas 5.1: Model File View Enhancements
Bin Name determined by Attributes and/or Group� IDEAS_send_option_bin_attributes � TC_GROUP
View Filters are now retained between sessions
Page 4
© 2008. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM Software
Indicator for On the Workbench
All Occurrences Selected
Bins are no longer collapsed when sorting
Teamcenter Integration for I-deas 5.1: Absolute Occurrences
Component Orientations Displayed Properly for Design Configurations within the PSE
Page 5
© 2008. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM Software
Teamcenter Integration for I-deas 5.1: Multiple Configurations
Visualize All I-deas Assembly Design Configurations within the PSE
Page 6
© 2008. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM Software
External tool to store configurations for existing data: store_configs.bat
Teamcenter Integration for I-deas 5.1: Hide & Suppress States
Suppressed or Hidden Occurrences in I-deas Design Configurations will be Suppressed in PSE
Page 7
© 2008. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM Software
Teamcenter Integration for I-deas 5.1: Purge Revisions of a Single Item
Purges I-deas Dataset Types:� IdeasPart, IdeasAssembly, IdeasDrawing, IdeasFEM,
IdeasDrawingSet, DirectModel, IdeasAssemblyMotion
Purges Other Dataset Types as Defined by Preference
Page 8
© 2008. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM Software
Number of Item Revisions to Keep is Configurable
Delete Permissions Defined by Access Control List
Teamcenter Integration for I-deas 5.1: Send Related Drawings to I-deas
Related Drawings Can Now be Sent to I-deas
Page 9
© 2008. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM Software
Teamcenter Integration for I-deas 5.1: Send to I-deas from RMB
Use the “Send To…” Menu from the Right Mouse Button within My Navigator to Send Data to I-deas
Page 10
© 2008. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM Software
Teamcenter Integration for I-deas 5.1: CGM Dataset Creation During Save to Teamcenter
Page 11
© 2008. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM Software
Teamcenter Integration for I-deas 5.1: Configurable JT During Save to Teamcenter
� IDI files can be used as the intermediate format to create JT files� XT B-Reps can now be included in the JT files� Mass Properties Information in NX� Associatively Update to Newer Revisions in NX� Faster B-Rep Analysis in Teamcenter
(No Additional “On-The-Fly” Translation Necessary)
Page 12
© 2008. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM Software
� Clearance� Measurement� 3D Cross Section
� Reference Geometry output can be controlled
Teamcenter Integration for I-deas 5.1: Local Language Error Messages
Error Messages will now be displayed in Local Multi-Byte Languages� Japanese� Korean
Page 13
© 2008. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM Software
Teamcenter Integration for I-deas 6.0
Teamcenter Integration for I-deas (TcII) 6.0� Released on May 2, 2008� NX I-deas 5m2� Teamcenter 2007.1 MP3� HP-UX, Sun Solaris, Windows XP
Page 14
© 2008. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM Software
Enhancements� Integrated “Integration for I-deas” Window� Deep Copy for I-deas Revise� Support for 80 Character Fields� ETS for Multi-CAD Assemblies� Installation through the Teamcenter Environment Manager
Teamcenter Integration for I-deas 6.0:Integrated “Integration for I-deas” Window
Page 15
© 2008. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM Software
Teamcenter Integration for I-deas 6.0:Deep Copy For I-deas Revise
Teamcenter Engineering Deep Copy Rules can now be defined to support both I-deas and NX Datasets
� I-deas Datasets will NOT be copied when using:� Teamcenter Engineering: File, Revise � NX: Save & Save As
Page 16
© 2008. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM Software
� I-deas Datasets will be copied when using:� Teamcenter Engineering: I-deas, Revise� Teamcenter Integration for I-deas: Save & Save As
Supports Multi-CAD & Migration Workflows
Teamcenter Integration for I-deas 6.0:Support for 80 Character Fields
Fields previously limited to 32 characters in Teamcenter have been expanded and now the I-deas fields can use up to 80 characters
TC_Allow_Longer_ID_Name=TRUE
Page 17
© 2008. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM Software
Teamcenter Integration for I-deas 6.0:ETS for Multi-CAD Assemblies
ETS can process assemblies containing JT datasets from other CAD
Page 18
© 2008. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM Software
Teamcenter Integration for I-deas 6.0:Installation through TEM
Installation and database upgrade are now performed through the Teamcenter Environment
Page 19
© 2008. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM Software
Manager
www.siemens.com/plm
© 2008. Siemens Product Lifecycle Management Software Inc. All rights reserved
Siemens PLM Software