1 1180582-W2-C
These instructions must be left with the user
Installation Guide
Skyline Quadrant Enclosure
21180582-W2-C
Safety Information1. Careshouldbetakenwhendrillingintowallsandfloorstoavoidanyhiddenpipesor
wires.2. Westronglyrecommendthatallglasspanelsaremovedbyaminimumoftwopeople
andthatanyprotectivepackagingalongtheglassedgesiskeptinplaceforaslongaspossibletopreventdamagebeforeinstallation.
3. Duringinstallationwerecommendadditionalhelpinliftingheavydoorsandsidepanels.4. Wearprotectivefootwearwhenliftingpanels.5. Wear safety glasses when drilling.
Wall Preparation
GENERAL INFORMATION
The wa l l channe ls must be installed onto a tiled or waterproof finished flat andevenwallsurface.Failuretodoso will result in an unsatisfactory seal,whichmaycausepropertydamage.
INTRODUCTIONThankyouforpurchasingaqualityKOHLER®product.Toenjoythefullpotentialofyournewproduct,pleasetaketimetoreadthisguidethoroughly,havingdoneso,keepithandyforfuture reference.Thefollowingpagesaimtoprovidecomprehensiveinstallationinstructions,plusadviceonhowtocareandmaintainyourproduct.Werecommendthattheunitisinstalledbyaqualifiedplumberorengineer.
General1. Readalloftheseinstructionsandretainthisguideforlateruse.2. Passonthisguideintheeventofchangeofownershipoftheinstallationsite.3. Followallwarnings,cautionsandinstructionscontainedinthisguide.4. Removeallprotectivetapefromtheenclosurebeforeinstallation.
3 1180582-W2-C
6.0 mm
2.0 mm 3.0 mm
TOOLS REQUIRED
GUARANTEEFordomestic installations,yourenclosurehasthebenefitofourlifetimeguaranteewhichstartsfromdateofpurchase.
Fornon-domestic installations,weguaranteetheproductagainstanydefectinmaterialsorworkmanshipforaperiodofoneyearfromthedateofpurchase.
Fortermsandconditionsrefertothebackcoverofthisguide.
RecommendedUsageDomestic ü
LightCommercial ü
HeavyCommercial û
Healthcare û
41180582-W2-C
x 1
x 2
x 1
PACK CONTENTS
x 6
x 6
x 2
1 x 3.0 mm A/F
x 2
1 x 2.0 mm A/F
x 8
x 4
x 4
x 4
x 4
x 1
5 1180582-W2-C
X 2 qX 2 q
X 2 q
X 2 qX 2 q
X 1 q
Pack 1
X 2 q
61180582-W2-C
X 2 qX 2 q
Pack 2
7 1180582-W2-C
INSTALLATION
Note!Coverthetraywastetopreventthelossofsmallparts. Note! Protect the tray surface during enclosure installation.
1
Note! Make sure that the wallshavebeentileddownto the tray.
Height of Enclosure (mm) 1900
Min/Max Frame Adjustment Enclosure Size Minimum (mm) Maximum (mm)800 768 798
900 868 898
1000 968 998
1200 1168 1198
(a) Install the shower tray in accordance with the manufacturer’s instructions. Caution!Makesurethattheshowertrayislevelandthatthewallsarevertical
andsquare.
± 0 mm
8 mm
a
b
c
81180582-W2-C
2
(a) Removethewallchannel.
9 1180582-W2-C
3
(a) Positionthewallchannelonthewall.Usingaspiritlevelmakesurethatitisupright.
(b) Markthepositionofthefixingholes,thenremovethewallchannel.(c) Drillwitha6mmmasonrybit (notsupplied)andplugusing thewallplugs
(supplied).
8 mm
± 0 mm
6 mm
x3
x3
x3
a
b
c
101180582-W2-C
4
(a) Positionthesecondwallchannelonthewall.Usingaspiritlevelmakesurethatitisupright.
(b) Markthepositionofthefixingholes,thenremovethewallchannel.(c) Drillwitha6mmmasonrybit (notsupplied)andplugusing thewallplugs
(supplied).(d) Positionthewallchannelonthewallandinstallthefixingscrews.(e) Fullytightenthefixingscrews,makingsurethatthewallchannelisupright.
8 mm
± 0 mm
6 mm
x3
x3
x3
a
d
c
b
11 1180582-W2-C
5
b
a+ 5 mm
bH
2 O
(a) Cutthesealtolengthandfitontotheglass.(b) Fittheglassintothebottomtrackmakingsurethattheseallocatescorrectly.
121180582-W2-C
6
(a) Fittheplasticretainersandinstallthescrewstosecurethetheassembly.
13 1180582-W2-C
57
(a) Cutthesealtolengthandfittothetopoftheglass.(b) Fitthetoptrackovertheglassandsealmakingsuretheseallocatescorrectly.1
+ 5 mm
1
+ 5 mm
a
a
b
c
H2 O
H2O
141180582-W2-C
8
(a) Fittheplasticretainersandinstallthescrewstosecurethetheassembly.
15 1180582-W2-C
9
x3
a
b
(a) Installthefirstwallchannelintothedoorframeandholdinposition.(b) Installthedoorframeoverthewallchannelthathadbeensecuredtothewall
earlier.(c) Adjustthedoorframesothatitisinthecorrectposition.(d) Installthewallchannelfixingscrewsthroughtheaccessholesinthedoorframe.(e) Fullytightenthefixingscrews,makingsurethatthewallchannelisupright.
X3
161180582-W2-C
90° 90°
± 0 mm± 0 mm
x3
510
3.0 mm
(a) Usingthe3.0mmhexagonalwrench(supplied),turnthrough90°tolockthedoorframeinposition.
17 1180582-W2-C
90° 90°
± 0 mm± 0 mm
x3
511
3.0 mm
(a) Usingthe3.0mmhexagonalwrench(supplied),turnthrough90°tolockthedoorframeinposition.
181180582-W2-C
(a) Install the seals to the glass.
512
SideProfile
19 1180582-W2-C
513
(a) Installtheflexibletrackinfillstriptothetopandbottomtracks.
201180582-W2-C
514
12
a
c
b
(a) Installtheinfillstripsasshownabove.
21 1180582-W2-C
515
a
c
b
d
(a) Turn the door so that it in the correct orientation.(b) Fullyturntheallenkeyclockwiseonbothtoprollerstolockrollersinuppermost
position.(c) Refitthedoorbyfirstlocatingthetoprollerassembliesonthetrack.(d) Fittherollercovers.
221180582-W2-C
516
Ifthedoorisoutofsquare,adjustasfollows:(a) Unlocktherollerassemblies(b) Adjustthedoorasrequired.(c) Locktherollerassemblies.(d) Fitthechromecovers.
a
b
c d
23 1180582-W2-C
a
c
b
d
517
(a) Unlockthebottomrollerassemblies.(b) Movethebottomrollerassembliesupordownuntiltheylocatecorrectlyinthe
bottom track and release correctly using the roller release buttons.(c) Lockthebottomrollerassemblies.(d) Fitthechromecovers.
241180582-W2-C
518
90010001200
90010001200
800 800
(a) Fitthesealstothesideofthedoors.(b) Fitthemagneticsealstothedoorsmakingsuetheylockcorrectly.
25 1180582-W2-C
x 1
x 2
x 1
2.0 mm
519 520
521
261180582-W2-C
522
==
(a) Fittherubberdoorstoptothetopandbottomtracks,makingsureitiscentrallylocated.
27 1180582-W2-C
(a) Applysealantinaccordancewiththesealantmanufacturersinstructionsalongthe outside surfaces of the door frame only.
(b) Allow the silicone sealant to cure for 24 hours before use.(c) Fittheplasticcoverstothetopoftheextrusions.
ab
23
281180582-W2-C
MAINTENANCEGeneral MaintenanceProviding the shower enclosure hasbeen correctly installed and is operated inaccordancewiththeinstructionscontainedinthisguide,difficultiesshouldnotarise.
Ifanymaintenanceisrequiredthenitmustbecarriedoutbyacompetenttradespersontowhomthemaintenanceinstructionsareprovided.
Beforereplacinganypartsensuretheunderlyingcauseofthemalfunctionhasbeenresolved.
CleaningWarning!Manyhouseholdcleanerscontainabrasiveandchemicalsubstancesandshouldnotbeusedforcleaningpainted,platedorplasticfittings.Thesefinishesshouldbecleanedwithamildwashingupdetergentorsoapsolutionandthenwipeddryusingasoftcloth.
CareTopreservethebeautyofyourshowerenclosureformanyyears,pleaseobservethefollowingcareinstructions:
Rinseglassand framewithclearwateraftershowering.Removewaterdropletswithasqueegee.Donotrubdry!Tocleanyourshowerhygienicallyandeasily,werecommend the use of a biodegradable cleanser.
Regular cleansingwith a biodegradable cleanser prevents stubborn stains andensures a clean and hygienic surface for many years. Do not use scouring or caustic cleansersunderanycircumstances!Thesecandamagethesurfaceoftheframe,glassanddecorativepartsaswellastheplasticparts.
Chrome PartsUseonlycleansersexpresslyspecifiedforchrome!
29 1180582-W2-C
SPARE PARTS
301180582-W2-C
SPARE PARTS
1 1781.376 HandleSpare
2 1781.419 SliderTopBearingSpare
3 1781.420 SliderBottomBearingSpare
4 1781.380 LockingMechanismSpare
5 1781.381 InfillSpare
6 1781.511 Quad Seal Pack
7 1781.500 800PanelSpare
1781.501 900PanelSpare
1781.502 1000PanelSpare
1781.503 1200PanelSpare
8 1781.377 DoorTopCapSpares
9 1781.499 QuadrantDoorSpare
31 1180582-W2-C
1
5
6
4
4
4
4
4
4
2 2
2
6
3 33
5
6 6
6
7 7
9 9
88
321180582-W2-C ©KohlerCo.March2013
0044 844 571 0048
Kohler Mira LimitedCustomer Services Dept,1 Penrose Place,Skelmersdale,WN8 9PR
To Contact Us: UK
Fax: 0044 844 571 7157
CUSTOMER SERVICE
E-mail: [email protected]
To Contact Us: Eire Only
0844 571 0048
Fax: 0844 571 7157
Helpdesk ServiceOur Customer Services Team is comprehensively trained and can offer help and advice, spare parts, accessories or a service visit.
We will need you to have your model name, model number and date of purchase.
KOHLER® Website (www.KOHLER.co.uk)From our website you can download additional user guides or request a service visit.
Spares and AccessoriesWe hold the largest stocks of genuine Kohler spares and accessories.Contact us for a price and to purchase spares or accessories.
Service / RepairsNo one knows our products better than our nationwide team of Service Technicians. We can carry out service or repair work to your product both during and after the guarantee period.
Ask about our fi xed price service repairs.
GuaranteeYour enclosure has the benefi t of our lifetime guarantee which starts from the date of purchase.To activate this guarantee, you must return your completed registration card with a copy of proof of purchase from an approved Kohler retailer within 30 days of purchase.This guarantee is in addition to your statutory rights and is subject to conditions (see registration card).
What to do if something goes wrongIf your product does not function correctly when you fi rst use it, contact your installer to check that it is installed in accordance with the instructions in this manual.
If this does not resolve the issue, contact our Customer Services Team who will offer you or your installer help and advice.
Kohler Mira Limited, Cromwell Road, Cheltenham,Gloucestershire, GL52 5EP, UK
13EN 14428:2004 + A1: 2008
By Post:
Kohler is a registered trade mark.The company reserves the right to alter product specifi cations without notice.
(298)