SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 1WinCC_V5_xie8.ppt/Sch
SIMATIC WinCC V5.0
WinCC V5 Under Windows NT
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 2WinCC_V5_xie8.ppt/Sch
Highlights of the Version
MultiServer
Web Navigator
Totally Integrated Automation
Efficient Configuration
Functional Enhancements in the Graphics Designer
Enhancements to Communications
Enhancements in WinCC V5 Service Pack 1
SIMATIC WinCC V5.0
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 3WinCC_V5_xie8.ppt/Sch
Multi ServerOverview
Distribution of Servers Higher Performance Profile Easier Expansion of the System Better Performance
Multi Client as a Common View of the Servers
WinCC - scaleable from a single-user station up to a distributed system.
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 4WinCC_V5_xie8.ppt/Sch
Distribution of ServersOverview
Performance Profile 6 servers (redundant pairs too) with up to 16 clients (tested performance profile)
Distribution is Solved by Configuration Functional distribution, e.g. for archiving and visualization Distribution to subsystems
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 5WinCC_V5_xie8.ppt/Sch
Distribution of ServersFunctional Distribution
Alarm ServerVisualization ServerTrend Server
Multi Client
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 6WinCC_V5_xie8.ppt/Sch
Distribution of ServersDistribution to Subsystems
Plant Section 2 Plant Section 3Plant Section 1
Multi Client
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 7WinCC_V5_xie8.ppt/Sch
Distribution of ServersConfiguration of Distributed Systems
WinCC Server WinCC Multi Client
1. Transfer/Conversion of Version 4 Projects and Pictures
2. Independent Configuration of the Servers (in accordance with Version 4.x)
3. Generation of Server Data
The server package contains a list of picture names, variables and archives of the server that a Multi Client needs for its configuration.
4. Configuration of the Multi Client Project
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 8WinCC_V5_xie8.ppt/Sch
Multi ClientOverview
The Multi Client takes an important part in a distributed system
A Multi Client provides a common view of the process data of distributed servers in one picture all the measured value archives, e.g. in one curve window all the message archives the pictures/picture windows of different servers
Integration and bringing together of different server projects at the Multi Client
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 9WinCC_V5_xie8.ppt/Sch
Multi ClientConfiguration of the Multi Client
The Multi Client has its own project
The server data is loaded on the Multi Client
The view of the different servers is based on a new property: the server prefix ServerName::TagName
The system automatically transfers the server prefix to scripts, controls, pictures on the Multi Client
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 10WinCC_V5_xie8.ppt/Sch
Multi ClientOverview of Distributed System
WinCCServer2
WinCC Multi Client
WinCCServer1
Standard Client
The Multi Client has its own project including additional pictures, e.g. for a common plant-wide alarm view.
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 11WinCC_V5_xie8.ppt/Sch
Multi ClientView of Tags of Different Servers
I/O field linked to “Server1::Tag1”
I/O field linked to “Server2::Tag2”
WinCCServer2
WinCC Multi Client
WinCCServer1
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 12WinCC_V5_xie8.ppt/Sch
Multi Client - View of Process Value Archives of Different Servers
Server1::Tag1
Server2::Tag2
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 13WinCC_V5_xie8.ppt/Sch
Multi Client - View of Message Archives of Different Servers
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 14WinCC_V5_xie8.ppt/Sch
Multi Client - View of Picture Windows of Different Servers
WinCCServer2
WinCC Multi Client
WinCCServer1
Server1:: Server2::
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 15WinCC_V5_xie8.ppt/Sch
Serv 1 Overview Picture
Multi ClientView of Pictures of Different Servers
Server2Server1
Serv 2 Overview Picture
WinCC Multi Client
Multi Client Overview Picture
Server1 Server2
Server Picture
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 16WinCC_V5_xie8.ppt/Sch
Web NavigatorOverview
Web Navigator Server Communication to the WinCC Server Administration of Access Rights
Web Navigator Client Operation and Monitoring Over the Web Limited operator inputs or purely view only function depending on the
access rights Minimum installation including WinCC ActiveX controls via network too
WinCC Goes Web
Operation and monitoring of the plant via the Worldwide Web
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 17WinCC_V5_xie8.ppt/Sch
Web Navigator Plant Configuration I
HTTP Request
HTTP Result
Firewall
Browser
Web Client Web ServerWinCC Data Source
Web Server
Client-PC
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 18WinCC_V5_xie8.ppt/Sch
Web NavigatorPlant Configuration II
Browser
HTTP Request
Web Client Web ServerWinCC
Web Server
WinCC Data Source
HTTP Result
Firewall
e.g.OPC
Client PC
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 19WinCC_V5_xie8.ppt/Sch
Web NavigatorPlant Configuration III
Browser
Http Request
Web Client Web ServerWinCC
Web Server
WinCC DataSource
Http Result
Firewall
Client PC
Maximum safety by physical separation of plant network and Internet
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 20WinCC_V5_xie8.ppt/Sch
Web Navigator Client Strengths
Plant visualization and operation across the Interne / Intranet Web Navigator Client is a thin client (up to 50 clients) View of the plant or manufacturing information for Managers Direct plant control by remote diagnostics for example
Safety by several levels of security User-specific password Firewall technology Support of encoded communication
Minimal installation at client side (no entire WinCC system)
Direct use of WinCC pictures for the web
Optimized communications and performance Optimization of WinCC pictures Pictures can be transferred directly
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 21WinCC_V5_xie8.ppt/Sch
Web Navigator Client Limitations of the Web Client
When transferring the comprehensive WinCC Runtime functionality to the minimum web client execution environment, there are some limitations:
No logs (log output on the web client is not supported) No online configuration of server projects No user archives No global scripts
Project and global functions must be present on the local system: this is of course not possible with a Web client. As a result, these functions are not executed on the Web client.
The system does support event-triggered scripts (e.g. on mouse click) in pictures and on objects.
Referenced graphics (e.g. bitmaps) on buttons, graphic objects etc. are not displayed
No full PCS7 support, e.g. navigation through pictures
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 22WinCC_V5_xie8.ppt/Sch
Totally Integrated Automation Overview
Direct Use of STEP 7 Symbols in WinCC
STEP 7 Block Call from WinCC Runtime
Entry into STEP 7 Hardware Diagnostics
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 23WinCC_V5_xie8.ppt/Sch
Totally Integrated AutomationInterconnection of STEP7 Symbols
WinCC Project as a Part of the STEP 7 Project
Interconnection of STEP 7 Symbols from the WinCC Tag Dialog
WinCC tag dialog box of the Graphics Designer with view of the STEP 7 data store.
•No duplicate input of tags.
•Direct access to STEP 7 data.
•Addressing errors avoided due to consistency
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 24WinCC_V5_xie8.ppt/Sch
Totally Integrated Automation STEP 7 Block Call
STEP 7 Block Call from WinCC Runtime Representation of active networks Return to the corresponding WinCC picture Navigation to different places of use
Jump to a defined STEP 7 network from a WinCC picture in runtime for diagnostic purposes.
Rapid, guided diagnostics in the STEP 7 program.
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 25WinCC_V5_xie8.ppt/Sch
Totally Integrated Automation STEP7 Block Call Overview
Network Entry
Return to the WinCC Picture
Symbol Table
Symbol Places of UseFB1 Network xFB2 Network y
S7 Network
(Automatic)
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 26WinCC_V5_xie8.ppt/Sch
Totally Integrated Automation Entry into STEP 7 Hardware Diagnostics
Start of the STEP 7 function „hardware diagnosis“ from WinCC Runtime
Hardware error detection in WinCC e.g. via a message
HW error
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 27WinCC_V5_xie8.ppt/Sch
Efficient Configuration Overview
Cross-Reference List Listing in table form of tags, pictures, functions ... Selective lists Central rewiring Jump from the cross-reference list to the tags' place of use
Display of all the dynamic properties of a picture
Dragging and dropping of tags
Rapid rewiring of tags in pictures
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 28WinCC_V5_xie8.ppt/Sch
Efficient Configuration Cross-Reference List
Listing in table form of tags, pictures, functions ...
Direct rewiring or jump to place of use
Subdivided by variables in use or not in use
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 29WinCC_V5_xie8.ppt/Sch
Efficient Configuration Cross-Reference List
Selective lists in accordance with the filter setting Selection
by objects, e.g. picturesas in use or not in use
Search in pictures, functions, archives, messages
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 30WinCC_V5_xie8.ppt/Sch
Efficient Configuration Picture Properties
Picture preview
Display of picture dynamization in an overview or selectively by type of dynamization
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 31WinCC_V5_xie8.ppt/Sch
Efficient Configuration Dragging & Dropping Tags
Tag linking in the Graphics Designer by means of drag & drop
Rapid rewiring of variables in pictures
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 32WinCC_V5_xie8.ppt/Sch
Functional Enhancements (Graphics Designer) User Interface
Tag and ActiveX Toolbar
Multiline Button Labels
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 33WinCC_V5_xie8.ppt/Sch
Functional Enhancements (Graphics Designer) Trend/Alarm Windows as ActiveX Controls
Conversion of Application Window to ActiveX Controls Direct display and configuration of message and trend windows after pasting
the controls in the Graphics Designer Storage of sample controls in the library
New Functions of the Controls Online trend window without its own archive Free definition of number of places after decimal point in Table Control
Quick configuration dialog
Direct display of trend and alarm windows in Graphics Designer
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 34WinCC_V5_xie8.ppt/Sch
Functional Enhancements (Graphics Designer)Display of DXF Data
Display of DXF Data (E-Plan, AutoCAD) Output via an ActiveX control Zoom function in the view Wizard support Central or local data storage possible of DXF files
View of the plant data for trouble-shooting, for example, right down to the wiring dia-gram from WinCC Runtime.
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 35WinCC_V5_xie8.ppt/Sch
Enhancements to Communication General Expansion of Channels
Channel-specific help files
Channel-specific log files
Ehanced channel diagnosis for the following channels: SIMATIC S5 Ethernet Layer 4 / TF SIMATIC S5 AS511 / Serial 3964R SIMATIC S7 Protocol Suite
Diagnosis of com-munications problems like addressing errors in the LOG file, for example.
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 36WinCC_V5_xie8.ppt/Sch
Enhancements to Communication Expansion of Channel Diagnosis
Trace Control
Connection Monitoring
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 37WinCC_V5_xie8.ppt/Sch
Enhancements to Communication Expansion of the SIMATIC S7 Channel
Increase in the number of units for Profibus (CP5412A2) Industrial Ethernet (CP1413) For this type of communications, you can fit two CPs
Write jobs can be processed with priority
Support for the S7-400's H-CPU Profibus Industrial Ethernet
Connection of twice as many controllers.
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 38WinCC_V5_xie8.ppt/Sch
Enhancements to Communication WinCC Redundancy
RedundantProfibus orIndustrial Ethernet
Redundant WinCC Server
WinCC Clients
S7-400-H
WinCC Redundancy:a Global Concept
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 39WinCC_V5_xie8.ppt/Sch
Enhancements to Communication Communications Manual
Overview of Communications
Help in Making Decisions
Numerous very comprehensive examples ranging from AS through drivers to WinCC
Sample projects for STEP 5 / 7 and WinCC
Notes on diagnostics•A communications manual for beginners and experts.
•Establishing communications explained step-by-step.
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 40WinCC_V5_xie8.ppt/Sch
Enhancements to Communication OPC
Enhancement of OPC capability by adding functions of the current V2.0 specification
Support for Automation and Customer Interface Direct access to the Automation Interface via VBA (e.g. Excel)
OPC Server
OPC Custom Interfaces
OPC Automation Interfaces
OPC Client
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 41WinCC_V5_xie8.ppt/Sch
Enhancements in WinCC V5 Service Pack 1
The WinCC V5.0 SP1 Update can be performed by an additional installation procedure. A previous de-
installation of WinCC V5.0 ist not necessary.
Service Pack 1WinCC V5.0 WinCC V5.0 SP1
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 42WinCC_V5_xie8.ppt/Sch
Enhancements in WinCC V5 Service Pack 1 System Channel
• A system channel can be added as a channel DLL
• System time, date, weekday tag are available within WinCC and can be passed to other systems
• The current CPU and memory usage can be processed within WinCC.
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 43WinCC_V5_xie8.ppt/Sch
Enhancements in WinCC V5 Service Pack 1 New TCP/IP Channel Unit for S5
• The S5 transport channel contains a new channel unit for TCP/IP operation.
• This channel unit is an alter- tive to the ISO transport channel unit.
• Any ethernet board can be used..
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 44WinCC_V5_xie8.ppt/Sch
Enhancements in WinCC V5 Service Pack 1 Quality Codes for OPC Channel
• The OPC channel includes quality codes.
• These quality codes indicate information about status of the variable values. („good“, „bad“, „unknown“)
Direct rewiring or jump to the location of usage.
SIMATIC HMI - Human Machine InterfaceWinCC Version 5SIMATIC HMI - Human Machine InterfaceWinCC Version 5
A&D PT1 M/05.04.00/N° 45WinCC_V5_xie8.ppt/Sch
Enhancements in WinCC V5 Service Pack 1 Cross-Reference Information from V4 Projects
• Scripts within a version 4 project can be automatically extended cross-reference information. • New project functions can be checked in the cross reference list as well.
• The smart tool „ScriptUpgrade“ is to be found on the CD-ROM.