55
5-1
Table of ContentsSection 5
Overfill Protection
Civacon Socket Assemblies ................................................................................... 5-22 – 5-25Civacon Liberty Monitor ............................................................................................... 5-16Civacon Optic Sensors ........................................................................................ 5-11 – 5-21Civacon ROM II ....................................................................................................... 5-8 – 5-10FloTech Overfill Detection Systems ..................................................................5-41 – 5-46Ground Bolt & Ground Ball ................................................................................ 5-36 – 5-37Civacon Load Rack Monitors, Plugs & Cords ............................................................ 5-53RomLink Plug-N-Load .............................................................................................. 5-1 – 5-7Scully Intellicheck 2 .............................................................................................5-26 – 5-28Scully Load Anywhere Monitor ..................................................................................... 5-37Scully Optic Sensors ............................................................................................5-29 – 5-32Scully Sockets & Adaptors ..................................................................................5-33 – 5-35Truck Identification Module ...............................................................................5-38 – 5-39Universal Truck Tester ...................................................................................................... 5-40
55
5-1
The Old Way The New Way
NewI n t r o d u c i n g
Only From Civacon
The Fast, Easy, Hassle-Free Way to Get Connected… and Stay Connected.
• Simple and quick for the OEM to install. Just mount, plug & test.
• Easy for the repair shop to retrofit. Saves their time and your money “chasing a problem” in old wiring.
• Keeps your tank in service longer and getting that “green light at the rack.” Your drivers will thank you!
• Always the right connection, with color-coded simplicity. Makes testing a breeze, too!
• Reliable in any environment – high performance cabling with pressure over-molded “best-in-class” triple sealed connectors and splices that guard against water and corrosion.
Our new ROMLink™ wiring system eliminates the slow, messy, and at times unreliable cut, strip & crimp method of wiring. Replace it with Plug-N-Load™ simplicity.
Connect with Civacon. To learn more call 888-526-5657 4304 Mattox Road • Kansas City, MO • 64150Phone: 888.526.5657 • Fax: 816.741.1061 www.civacon.com
Overfill System Wiring Innovation for Petroleum Tankers by
Overfill Detection System
Available for all standard configurations of petroleum tankers
5-2 5-3
55
PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-1061 4304 Mattox Road • Kansas City, MO 64150 • www.civacon.com
ROMLink™ “Plug-N-Load” System
Features and Benefits
• Crimp-Free Installation • No Special Tools or Training Required • Fits up to Five Compartment Layout Configurations • Can be added to existing trucks with overfill systems • Completely Sealed harness system that will last in
any environment • Components color-coded for easy identification
Before After
Rev. B, Apr 2010
The Civacon ROMLink™ “Plug-N-Load” System represents a major revolution in the Overfill Detection World. Since the introduction of overfill electronics on petroleum and other product-hauling tankers, OEM’s, Installers, Repair Shops and End-Users have been frustrated by the way in which electronics and other components are connected. Unless the crimps are installed with absolute precision, the longevity of the system is compromised.
In the desire to eliminate this frustrating cycle, Civacon has developed the ROMLink™ “Plug-N-Load” System. This system not only improves trouble points, but eliminates them.
Civacon’s retrofit system is a link to a fast installation and a worry-free future. The ROMLink™ gives you a hassle-free installation which allows you to “Plug-N-Load.”
5-2 5-3
55
PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-1061 4304 Mattox Road • Kansas City, MO 64150 • www.civacon.com
ROMLink™ “Plug-N-Load” System
Ordering Specifications
RL
1 - 5 Compartments T = Top Sensor B = Bottom Sensor R = ROM Monitor D = Dual Socket
7” Probe Length Qty. 12” Probe Length Qty. 14” Probe Length Qty. 18” Probe Length Qty.
Examples
RL4-T-0400 - 4 Comp. Harness, w/ Top Sensors. (4) 12” Sensors
RL5-T-2030 - 5 Comp. Harness, w/ Top Sensors. (2) 7” Sensors & (3) 14” Sensors
RL4-TR-2002 - 4 Comp. Harness, w/ Top Sensors & ROM Monitor. (2) 7” Sensors & (2) 18” Sensors
RL5-TBRD-2111 - 5 Comp. Harness Top & Bottom, Top Sensors, Bottom Sensors, ROM Monitor & Dual Socket Box. (2) 7” Sensors, (1) 12” Sensor, (1) 14” Sen-sor & (1) 18” Sensor
RL5-TBRD-3020 - 5 Comp. Harness Top & Bottom, Top Sensors, Bottom Sensors, ROM Monitor & Dual Socket Box. (3) 7” Sensors & (2) 14” Sensors
T
B
S R
Optional Accessories ROMLink™ System Tester RLT-1 ROMLink™ Socket Hub RLH-1 - 3-1 Socket Hub RLH-2 - 2-1 Socket Hub Socket Hub required for applications requiring more than one socket
O = Optic Socket T = Thermistor Socket Ground Wire Installed in all ROMLink™ Sockets
RLH-2 (Shown)
RLT-1
5-4 5-5
55
PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-1061 4304 Mattox Road • Kansas City, MO 64150 • www.civacon.com
ROMLink™ “Plug-N-Load” System
Civacon’s retrofit kit, is a link to a fast installation and worry free future. The ROMLink™ gives you a hassle free installation which allows you to “Plug-N-Load”. The Civacon ROMLink™ “PLUG-N-LOAD” System represents a major revolution in the Overfill Detection World. Since the introduction of overfill electronics on petroleum and other product hauling tankers, OEM’s, Installers, Repair Shops and End Users have been frustrated by the way in which electronics and other components are connected together in the system. Unless the crimps are installed with absolute precision, the longevity of the system is compromised.
In the desire to eliminate this frustrating cycle, Civacon has developed the ROMLink™ “PLUG-N-LOAD” System. This system not only improves trouble points, but eliminates them.
Features and Benefits
• Crimp Free Installation • No Special Tools or Training Required • Fits All Compartment Layout Configurations • Can be added to existing trucks with overfill systems • Completely Sealed harness system that will last in
any environment • Components color coded for easy identification
Before After
Rev. A, May 2009
5-4 5-5
55
PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-1061 4304 Mattox Road • Kansas City, MO 64150 • www.civacon.com
Civacon introduces the next enhancement to our newROMLink™ Optic Overfill Sensor. This new sensor now features our enhanced electronics located in the cap. A curly cable and modular connector securely join the sensing tube to the cap for a trouble-freeinstallation.
ROMLink™ 2-Wire Optic “Plug-N-Load” Sensor
Overfill Features • “Plug-N-Load” Sensor will replace existing ROMLink™ Sensors
• New digital electronics in cap have extended temperature stabilized potting
• Modular connector joins sensing tube (containing just the optic head) to the cap’s electronics
• Dual O-ring seals in housing for improved sensor tube to housing sealing
• Zero glue or adhesive construction for wide chemical compatibility
• Still the industry’s best single flat surface optic prism design!
• Recessed, protected one piece molded, glass Pyrex® prism
• Completely new Housing and molded non-corrosive cap design
• No tools required for access, or adjustment of probe
• Sensors never need to be removed with electronics now in the cap
• Tamper Evident Tab on cap lets you add a seal to prevent sensor height tampering (sensor cannot be adjusted externally)
• North American Approval
• Operating Temperature -40º F (-40º C) to 160º F (71.1º C) Storage Temperature -70º F (-56.6º C) to 280º F (137.7º C) Tamper Evident Tab
Sensor Tube Retaining Spring. Squeeze ends together to adjust sensor height.
Rev. +, Mar 2010
Optic overfill sensors detect the presence of liquid at a preset level. The new Civacon ROMLink™ Sensor brings all the enhanced design features of our new Universal Sensor and more to the “Plug-N-Load” convenience of our ROMLink™ System. The new Sensor now has our digital electronics located in the cap, with a modular connector joining the sensing tube (containing just the optic head) to the cap’s electronics.
By having the electronics located in the cap, the sensing tube height needs to be only set once. The new one-piece Pyrex® glass prism and sensing devices in the tube should never need replacing. If the sensor’s electronics ever need to be serviced, it is simply a matter of removing the cap, unplugging the connector and plugging in a new cap assembly. No tools required! Plus there are no changes to the sensing height or any affect on the compartment’s vapor-tight integrity.
The features and benefits of these new sensors are available in our new ROMLink™ 5-wire sensor version as well (see separate data sheet).
5-6 5-7
55
PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-1061 4304 Mattox Road • Kansas City, MO 64150 • www.civacon.com
ROMLink™ 2-Wire Optic “Plug-N-Load” Sensor
REFERENCE CHART
ROMLink™ Part #
Old Civacon ROM Part # Description
1554-007 1051RL-007 Optic Overfill Sensor, RJ-11 Connector, 2” BSPP Parallel Port Housing, 7”
1554-0012 1051RL-0012 Optic Overfill Sensor, RJ-11 Connector, 2” BSPP Parallel Port Housing, 12”
1554-0018 1051RL-0018 Optic Overfill Sensor, RJ-11 Connector, 2” BSPP Parallel Port Housing, 18”
STK-007 Replacement Optic Overfill Sensor, RJ-11 Connector, No Housing, 7”
STK-0012 Replacement Optic Overfill Sensor, RJ-11 Connector, No Housing, 12”
STK-0018 Replacement Optic Overfill Sensor, RJ-11 Connector, No Housing, 18”
MaterialsSensor Cap - Glass Filled Nylon Cap O-ring - Silicone Sensor Housing - Aluminum Mounting O-ring - Viton® Locking Nut - Plated SteelSensor Shaft - Aluminum Prism - Pyrex® Glass Prism O-ring - Fluorosilicon Retaining Ring - Stainless
AN FLUID TRANSFER GROUP COMPANY
Product Specifications
Product Number 1554-007, 0012 or 0018 (See Below)
Sensing Length AdjustabilitySee Drawing
Electrical Leads RJ-11 Modular Connector
Weight 1.15 lbs. (0.521 kg)
Approvals North America
Temperature Range Operating Temperature -40º F (-40º C) to 160º F (71.1º C) Storage Temperature -70º F (-56.6º C) to 280º F (137.7º C)
**Special length sensors are available upon request
5-6 5-7
55
PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-1061 4304 Mattox Road • Kansas City, MO 64150 • www.civacon.com
1554 Series Optic Sensor (2-Wire)
PAR
TS B
REA
K D
OW
N
Rev. +, Mar. 2010
ITEM PART NUMBER DESCRIPTION QTY. ITEM PART NUMBER DESCRIPTION QTY.
1 STK-XXXX OVERFILL PROBE TUBE 1 8 H52845M SPRING 1
2 H52841 HOUSING BODY 1 9 H52844M O-RING, VITON 1
3 1356-2W CAP 2-WIRE OPTIC SENSOR 1
4 H52301M-1554 LABEL 1
5 H52842M O-RING, BUNA-N 2
6 H52477M LOCK NUT 1
7 H52898M SCREW 1
5-8 5-9
55
ROM II - RETAIN OVERFILL MONITOR SYSTEM Product Number Product Description
ROM II “Load Any Rak” SYSTEMS (Overfill & Retain Probes) 3022 2 Compartment System 3023 3 Compartment System 3024 4 Compartment System 3025 5 Compartment System 3026 6 Compartment System
Systems Include: (1) Model 1051-007 Top Sensor and (1) Model 1000 Bottom Sensor for each com-partment, (1) Model 3202-R Retain Overfill Monitor, (1) Model 2300 7-conductor wire, (1) Model 2530 Strain Reliefs and (2) Model 1910 Terminators for systems having less than six compartments.
ROM II “Load Any Rak” TOP ONLY SYSTEMS 3032 2 Compartment System 3033 3 Compartment System 3034 4 Compartment System 3035 5 Compartment System 3036 6 Compartment System
Systems Include: (1) Model 1051-007 Top Sensor for each compartment, (1) Model 3202 Retain Overfill Monitor, (1) Model 2310 7- conductor wire, (1) Model 2510 Bag of Strain Reliefs and (1) Model 1910 Terminator for systems having less than six compartments.
OPTIC SENSORS 1051-007 Adjustable Optic Overfill Top Sensor (2- wire) with Housing 1000 Optic Retain Bottom Sensor 1351-007 Replacement Optic Overfill Probe, No Housing 1910 Terminator
COMPATIBLE ONBOARD ROM II MONITOR 3202 1- 6 Compartment Onboard ROM Monitor, Indicator Lights 3212 1- 6 Compartment Onboard ROM Monitor, with Keys and Key Switch
3252 Replacement Onboard ROM Monitor
5-8 5-9
55
ROM II Overfill Detection System Monitor
Retained—Overfill On-Truck Monitoring System
3202-32021-6 Compartment onboard ROM IIMonitor, Indicator lights
3252-3252 Replacement Onboard ROMII Monitor
3252 Rug-3252Replacement Onboard ROM MonitorUpgrade Kit (from ROM to ROMII)
Ordering Specifications
Overfill DetectionEngineered andManufactured to HandleReal World Demands
Companies involved in the transportation andhandling of hazardous bulk commodities rely on realworld safeguarding against costly overfills every dayand they rely on Civacon to provide it. The ROM™ II Overfill Detection System ismanufactured to deliver years of worry-freeperformance under the most rigorous conditions.Its flexible 2-wire optic sensing system interfaceswith optic, thermistor or float-type rack monitors.Unique patented, built-in diagnostics differentiatebetween non-operating sensors, broken or corrodedconnections. The ROM II continuously checks for anysingle-point system failures more than 90 times per second. • Advanced 2-wire optic sensing system interfaces with
optic, thermistor or float-type rack monitors.
• Patented diagnostics differentiate between non-operating sensors, broken or corroded connections.
• Automatically monitors and continuously checks forsingle-point system failures more than 90 times per second.
• Three auxiliary inputs for vapor collection, brakeinterlock, pressure sensors or other add-ons.
• Socket status lights to confirm proper “connection-to-the-rack” signals.
PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-10614304 Mattox Road • Kansas City, MO 64150 • www.civacon.com
5-10 5-11
55
PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-1061 4304 Mattox Road • Kansas City, MO 64150 • www.civacon.com
Civacon introduces our new Socket Optic Overfill Sensor. A completely new sensor and housing with enhancedtechnology and design features.The non– polarized digitalelectronic circuitry design is a perfect fit for all your overfilldetection needs. Optic overfill sensors detect the presence of liquid at a preset level. The new Civacon Socket Sensor is fully backward compatible with our current Quick-Start™ Sensors and Monitors, as well as all industry standard signal formats. These new Socket Sensors feature an exclusive, non-polarized digital electronic circuitry design that will work directly with 2-wire (green plug) loading racks when wired directly to a green “thermistor” socket, as well as with all on-board Monitors like the Civacon ROM II. The sensor’s non-polarized electronic design means not having to worry about the sensor’s wire color or polarity anymore. The two grey wires can be wired as either signal or ground interchangeably. You can not wire it wrong!
The new Civacon Socket Sensors are a direct replacement for our 2-wire, Quick-Start™ (white & black wire) optic sensors. With their 2-wire industry compatible signal format, they are a perfect choice for your 2-wire overfill detection sensor applications.
The features & benefits of these new sensors are also available in our new 5-wire sensor version as well. (call us for more details)
2-Wire Socket Optic Level Sensor w/ Housing
Overfill Features • 2-Wire Socket Sensor will work with ROM II and Quick Start
2-Wire Systems
• Two grey wires for non-polarized connection as signal or ground
• New digital electronics with extended temperature-stabilized potting
• Dual o-ring seals in housing for improved sensor shaft-to-housing sealing
• Zero glue or adhesive construction for wide chemical compatibility
• Still the industries best single flat surface optic prism design!
• Recessed, protected one piece molded, Borosilicate glass prism
• Completely new Housing and molded non-corrosive Cap design
• No tools required for access, or adjustment of probe
• Approved to North American, Europe (ATEX) and World (IECEX) Standards
• Operating Temperature -40º F (-40º C) to 160º F (71.1º C) Storage Temperature -70º F (-56.6º) to 280º F (137.7º C)
• OPTIONAL: Tamper Evident Tab on cap lets you add a seal to prevent sensor height tampering (sensor can not be adjusted externally) Tamper Evident Tab
Sensor Tube Retaining Spring. Squeeze ends together to adjust sensor height.
Rev. C, MAY 201070000PA
5-12 5-13
55
PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-1061 4304 Mattox Road • Kansas City, MO 64150 • www.civacon.com
2-Wire Socket Optic Level Sensor w/ Housing
Product Specifications
Product Number Materials 1552G-007, 0012 or 0018 (See Below) Sensor Cap - Glass-Filled Nylon 1652G-007, 0012 or 0018 (See Below) Cap O-ring - Silicone Sensor Housing - AluminumSensing Length Adjustability Mounting O-ring - Viton See Drawing Locking Nut - Plated Steel Sensor Shaft - AluminumProduct Range Prism - Borosilicate Glass Refractive Index 1.37 to 1.60 Prism O-ring - Fluorosilicon Viscosity of less that 1000 SSU Retaining Ring - Stainless Steel Electrical Leads Two 18 ga. Stranded Wire Approvals 26” Long (Grey in Color) North America Europe (ATEX)Weight World (IECEX) 1.15 lbs. (0.521 kg) (with housing)
Temperature Range Operating Temperature -40º F (-40º C) to 160º F (71.1º C) Storage Temperature -70º F (-56.6º) to 280º F (137.7º C)
REFERENCE CHART
Socket Optic Sensor Part #
Old Quick Start Part # Description
1552G-007 1551-007 Optic Overfill Sensor, 2-Wire, 2” NPT Parallel Port Housing, 7”
1552G-0012 1551-0012 Optic Overfill Sensor, 2-Wire, 2” NPT Parallel Port Housing, 12”
1552G-0018 1551-0018 Optic Overfill Sensor, 2-Wire, 2” NPT Parallel Port Housing, 18”
1652G-007 1651-007 Replacement Optic Overfill Sensor, 2-Wire, No Housing, 7”
1652G-0012 1651-0012 Replacement Optic Overfill Sensor, 2-Wire, No Housing, 12”
1652G-0018 1651-0018 Replacement Optic Overfill Sensor, 2-Wire, No Housing, 18”
1455-1455 1355-1355 2” NPT Parallel Port Housing w/ Cap
12214 N/A Tamper Evident Tab Kit
5-12 5-13
55
PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-1061 4304 Mattox Road • Kansas City, MO 64150 • www.civacon.com
1552 Series Optic Sensor (2-Wire)
PAR
TS B
REA
K D
OW
N
Rev. +, Mar. 2010
ITEM PART NUMBER DESCRIPTION QTY. ITEM PART NUMBER DESCRIPTION QTY.
1 1652G-XXXX OPTIC OVERFILL PROBE 1 8 H52845M SPRING 1
2 H52931 HOUSING BODY 1 9 H52844M O-RING, VITON 1
3 H52936M CAP W/ U-CUP SEAL 1
4 H52301M-1552 LABEL 1
5 H52842M O-RING, BUNA-N 2
6 H52477M LOCK NUT 1 REPAIR KITS
7 H52898M SCREW 1 1455-1455 Probe Housing & Cap
** ALL ITEMS INCLUDED IN 1455-1455 EXCEPT ITEM 1 & 4
** H50070M PIPE PLUG KIT (not shown)
5-14 5-15
55
Model #1550 Thermo-OpticQuick Start Probe (2-wire 2" NPT)
PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-10614304 Mattox Road • Kansas City, MO 64150 • www.civacon.com
Rev. 0, January 2003
WASHER (1/4" SPLIT, S.S.)
SCREW (1/4-20 X 1/2 STL, FIL, S.S.)O-RING (PROBE ADJUSTING SCREW)
O-RING (BODY SENSOR TUBE)
PROBE ADJ. SET SCREW (1/4-20 X 27/32 STL, FIL, S.S.)
GREEN GROUNDING SCREW (#8-32 X 3/8 CMB, BND, DC)NAME PLATE (1550 SENSOR)
PROBE HOUSING (INCLUDES ALL ITEMS EXCEPT ITEMS 1 & 13)
8
13
1514
1112
910
ITEM
4
67
5
32
1N/A
7" (MAX.)5" (MIN.)
H50088M
H50070M
H50153MH50276MH50279M
H50524M
H50371MH50421M
PART NUMBER
1650-1650
D40023AH50066M
1355-1355C40030A
H50083MH50086M
H50080M
1/2" NPT
3 5/16"
3 1/4"
4 1/16"
15
PIPE PLUG (1/2" N.P.T.)
O-RING (CAP SENSOR)GASKET (BASE SENSOR)
LOWER HOUSING BODYUPPER HOUSING CAP
LOCK NUT (2" N.P.T.)
OPTIC SENSORDESCRIPTION
DRIVE SCREW
1
1
12
11
11
QTY.
1
12
1N/A
11
2
1
2
10
14
3
13
9
6
5
8
12
11
7
4
Replacement Par t s
5-14 5-15
55
Rev. A, March 2006
WASHER (1/4" SPLIT, S.S.)
SCREW (1/4-20 X 1/2 STL, FIL, S.S.)O-RING (PROBE ADJUSTING SCREW)
O-RING (BODY SENSOR TUBE)
PROBE ADJ. SET SCREW (1/4-20 X 27/32 STL, FIL, S.S.)
GREEN GROUNDING SCREW (#8-32 X 3/8 CMB, BND, DC)NAME PLATE (1050 SENSOR)
PROBE HOUSING (INCLUDES ALL ITEMS EXCEPT ITEMS 1 & 13)
8
13
1514
1112
910
ITEM
4
67
5
32
1N/A
7" (MAX.)5" (MIN.)
H50088M
H50070M
H50153MH50276MH50279M
H50524M
H50371MH50476M
PART NUMBER
1351-007
D40023AH50066M
1355-1355C40030A
H50083MH50086M
H50080M
1/2" NPT
3 5/16"
3 1/4"
4 1/16"
15
PIPE PLUG (1/2" N.P.T.)
O-RING (CAP SENSOR)GASKET (BASE SENSOR)
LOWER HOUSING BODYUPPER HOUSING CAP
LOCK NUT (2" N.P.T.)
OPTIC SENSORDESCRIPTION
DRIVE SCREW
1
1
12
11
11
QTY.
1
12
1N/A
11
2
1
2
10
14
3
13
9
6
5
8
12
11
7
4
Replacement Par t s
Optic Sensor (2-Wire 2" NPT)Model #1051-007 ROM ( Obsolete )
5-16 5-17
55
PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-1061 4304 Mattox Road • Kansas City, MO 64150 • www.civacon.com
Civacon introduces our new 5-Wire Optic Sensor. The new sensor and housing includesdigital technology and improved design features. This sensor is the perfect fit for your overfilldetection needs.
Optic overfill sensors detect the presence of liquid at a preset level. The new Civacon 5-Wire Sensor is fully compatible with all our current 5-Wire Sensors and Monitors, as well as all industry standard signal formats. These new Sensors feature an exclusive, digital electronic circuitry design that will work directly with 5-Wire loading racks when wired directly to a blue WOGA1 or SAE J-560 style “optic” socket, as well as with all Onboard Monitors like our Civacon Liberty™.
The new Civacon 5-Wire Sensors are a direct replacement for our 5-Wire Liberty™ optic sensors. The new 5-Wire output signal is compatible with the industry standard signal format, which makes it the right choice for any of your 5-Wire overfill detection sensor applications.
All of the features & benefits of these new sensors are also available in our new 2-wire sensor version as well (see separate data sheet).
5-Wire Optic Level Sensor
Tamper Evident Tab
Sensor Tube Retaining Spring. Squeeze ends together to adjust sensor height.
Rev. A, Mar 2010
Overfill Features • 5-Wire Probe output signal is compatible with the industry
standard output format
• New digital electronics with new temperature stabilized friendly potting
• Zero glue or adhesive construction for wide chemical compatibility
• Still the industries best single flat surface optic prism design!
• Recessed, protected one piece molded, all glass Pyrex® prism
• Completely new Housing and Cap design
• Molded non-corrosive cap with captive seal means no tools required for access, or adjustment of probe
• Tamper Evident Tab on Cap lets you add a seal to prevent sensor height tampering (sensor can not be adjusted externally)
• Housings and Replacement Sensors are 100% compatible with all previous Civacon 5-Wire models
• Approved to North American, Europe (ATEX) and World (IECEX)
• Operating Temperature -40º F (-40º C) to 160º F (71.1º C) Storage Temperature -70º F (-56.6º) to 280º F (137.7º C)
1. WOGA (Western Oil and Gas Association), the former name for the Western States Petroleum Association (WSPA)
5-18 5-19
55
PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-1061 4304 Mattox Road • Kansas City, MO 64150 • www.civacon.com
5-Wire Optic Level Sensor
5-Wire Part #
Old Civacon Part # Description
1112-007 1110-1110 Optic Overfill Sensor, 5-Wire, 2” NPT Parallel Port Housing, 7”
1112-0012 1110-0012 Optic Overfill Sensor, 5-Wire, 2” NPT Parallel Port Housing, 12”
1112-0018 1110-0018 Optic Overfill Sensor, 5-Wire, 2” NPT Parallel Port Housing, 18”
1302-007 1300-1300 Replacement Optic Overfill Sensor, 5-Wire, No Housing, 7”
1302-0012 1300S-0012 Replacement Optic Overfill Sensor, 5-Wire, No Housing, 12”
1302-0018 1300S-0018 Replacement Optic Overfill Sensor, 5-Wire, No Housing, 18”
REFERENCE CHART
Product Specifications
Product Number Materials 1112-007, 0012 or 0018 (See Below) Sensor Cap - Glass Filled Nylon Cap O-ring - Silicone Sensing Length Adjustability Sensor Housing - Aluminum See Drawing Mounting O-ring - Viton Locking Nut - Plated SteelProduct Range Sensor Shaft - Aluminum Refractive Index 1.37 to 1.60 Prism - Pyrex® Glass Viscosity of less that 1000 SSU Prism O-ring - Fluorosilicon Snap Ring - Stainless Electrical Leads 22 ga. Stranded Wire 26” Long Approvals North American Weight Europe (ATEX) 1.15 lbs. (0.521 kg) World (IECEX)
Temperature Range Operating Temperature -40º F (-40º C) to 160º F (71.1º C) Storage Temperature -70º F (-56.6º) to 280º F (137.7º C)
**Special length sensors are available upon request
5-18 5-19
55
PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-1061 4304 Mattox Road • Kansas City, MO 64150 • www.civacon.com
1112 Series Optic Sensor (5-Wire)
PAR
TS B
REA
K D
OW
N
Rev. +, Mar. 2010
ITEM PART NUMBER DESCRIPTION QTY. ITEM PART NUMBER DESCRIPTION QTY.
1 1302-XXXX OPTIC OVERFILL PROBE 1 8 H52845M SPRING 1
2 H52931 HOUSING BODY 1 9 H52844M O-RING, VITON 1
3 H52936M CAP W/ U-CUP SEAL 1
4 H52301M-1112 LABEL 1
5 H52842M O-RING, BUNA-N 2
6 H52477M LOCK NUT 1 REPAIR KITS
7 H52898M SCREW 1 1455-1455 Probe Housing & Cap
** ALL ITEMS INCLUDED IN 1455-1455 EXCEPT ITEM 1 & 4
** H50070M PIPE PLUG KIT (not shown)
5-20 5-21
55
(5 Wire 2" NPT)
Rev. 0, January 2003
PROBE HOUSING (INCLUDES ALL ITEMS EXCEPT ITEMS 1, 4 & 12)
H50284M12
1413 H50371M
H50524M
11109
78
56
2N/A
43
ITEM
1
H50279MH50276MH50153M
H50080M
H50086MH50083M
H50088M
PART NUMBER
C40030A1355
H50066MD40023A
1300
3 5/16"
5" (MIN.)7" (MAX.)
3 1/4"
NAME PLATE (1110 SENSOR)
GREEN GROUNDING SCREW (#8-32 X 3/8 CMB, BND, DC)PROBE ADJ. SET SCREW (1/4-20 X 27/32 STL, FIL, S.S.)
OPTIC SENSORDESCRIPTION
DRIVE SCREW
LOCK NUT (2" N.P.T.)
UPPER HOUSING CAPLOWER HOUSING BODY
GASKET (BASE SENSOR)O-RING (CAP SENSOR)
O-RING (BODY SENSOR TUBE)
O-RING (PROBE ADJUSTING SCREW)SCREW (1/4-20 X 1/2 STL, FIL, S.S.)
WASHER (1/4" SPLIT, S.S.)
1
11
1
21
21
11
QTY.
N/A1
21
1
1/2" NPT
10
14
3
2
1
6
5
8
13
7
11
9
4 1/16" 12
4
PIPE PLUG (1/2" N.P.T.)15 H50070M 1
15
Replacement Par t s
Model #1110 Optic Sensor ( Obsolete )
5-20 5-21
55
Optic Sensors
PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-10614304 Mattox Road • Kansas City, MO 64150 • www.civacon.com
5-Wire Optic Sensor
2-Wire Optic Sensor
Optic Retain Bottom Sensor w/ weld coupling
Optic Sensors are designed for overfill detection ofliquid petroleum products. They are instantlypermissive and specially designed for safe, trouble-freeuse with all Rack Monitors.
Features and Benefits• Conforms to API RP 1004 and EN13922 standards.
• Intrinsically safe.
• Instant permissive signal (no warm-up time).
• Easy adjustable shaft when shorter length is necessary.
• UL approved for use in Class I, Division II, Groups Cand D hazardous locations.
• ATEX approved for Zone 0 hazardous locationsII 1 G EEx ia II B T4.
• Continuous self checking system operation.
• Withstands steam cleaning of the tank.
Optic Sensors
1110-1110Adjustable 5-Wire Optic Sensor, with 2"NPT Housing, 7'' Shaft Length
1300-1300Replacement 5-Wire Optic Sensor, 7'' Shaft Length, No Housing
1051-007Adjustable 2-Wire Optic ROM Overfill TopSensor, with 2" NPT Housing, 7'' ShaftLength, (replaces 1050-1050)
1351-007Replacement 2-Wire Optic ROM OverfillSensor, 7'' Shaft Length, No Housing(replaces 1350-1350)
1551-007Adjustable 2-Wire Quick Start™(Thermo-Optic) Sensor, with 2'' NPTHousing, 7'' Shaft Length
1651-007Replacement 2-Wire Quick Start™(Thermo-Optic) Sensor, 7'' Shaft Length,No Housing (replaces 1650-1650)
1000ROptic Retain Bottom Sensor with BottomIn-Line Housing and Weld Coupling
Ordering Specifications
Sensors also available in other lengths upon request.
5-22 5-23
55
PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-1061 4304 Mattox Road • Kansas City, MO 64150 • www.civacon.com
Single API Socket with Ground Wire
Socket Features • Pre-wired, tested and ready for installation
• Aluminum Hard-Coated Nose Ring and J-Slots for long wear
• Ground Wire Installed
• Vehicle Identification Wire Installed
• Stainless-steel Contact Pins
• Color-coded for easy identification
• Lightweight, durable, low-cost caps with raised surfaces for better grip included
• Stainless-steel hardware included
Civacon releases its new Optic and ThermistorSockets with hard-coated nose ring and J-Slots for longer wear. These sockets are stronger than stainless– steel rings and come with a lifetime warranty.
4102-4102 Wiring Shown
Ground Verification Wire
VehicleIdentification Wire
Vehicle-mounted sockets connect Optic, Thermistor, and J560-type level sensors on trailers and truck tanks to their compatible monitor plugs installed at loading terminals.
Civacon, the name you can trust for quality overfill prevention products, introduces optic and thermistor single sockets with ground verification wired inside the socket. Ground verification is needed to load at terminals where the loading-rack monitor requires a special modified signal as part of its ground verification operation. An accessory wire is also connected to the ground wire for vehicle identification systems.
For proper installation, “the ground wire” MUST be securely fastened to the tanker chassis; Civacon has pre-wired it to pin No. 9 on the overfill-detection sockets to provide proper ground verification.
Rev. A, Mar 2010
5-22 5-23
55
PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-1061 4304 Mattox Road • Kansas City, MO 64150 • www.civacon.com
Single API Socket with Ground Wire
REFERENCE CHART
Socket Part #
Old Civacon Socket Part # Description
4102-4102 4100-4100 API Optic Pattern Socket, 3 J-Slots with 6 pins
4402-4402 4401-4401 API Thermistor Pattern Socket, 4 J-Slots with 10 pins
4102RL 4100RL ROMLink, API Optic Pattern Socket, 3 J-Slots with 6 pins
4402RL 4401RL ROMLink, API Thermistor Pattern Socket, 4 J-Slots with 10 pins
Product SpecificationsProduct Numbers 4102-4102 - Standard Optic Socket 4402-4402 - Standard Thermistor Socket 4102RL - ROMLink Optic Socket 4402RL - ROMLink Thermistor Socket
MaterialsHousing - Aluminum J-Slot Collar - Hard-coated AluminumPins - Stainless-steel
Dimensions 5.75” W x 4.75” H x 3.5” D
Weight 2.7 lbs. (1.224 kg)
Temperature Range Operating Temperature -40º F (-40º C) to 160º F (71.1º C)
INSTALLED BY CIVACON
GROUND LUG
WHITE (GROUND)
YELLOW (SIGNAL TO FIRST)
GREEN (DIAGNOSTIC)ORANGE (SIGNAL FROM LAST)GREEN (GROUND VERIFICATION)
RED (POWER)
FIELD SPLICE
(GROUND)BLACK
9
6
8
45
10
4102-4102 WIRING DIAGRAM
INSTALL JUMPER WIRES FROM:7 TO 6, 6 TO 4, 8 TO 3, AND 3 TO 5
5 TO 1 AND 4 TO 2
4402-4402 WIRING DIAGRAM
INSTALLED BY CIVACON
GROUND LUG
WHITE (GROUND)
ORANGE
RED (POWER)
FIELD SPLICE
(GROUND)BLACK
1
9
6
7
8 2
45
103
GREEN (GROUND VERIFICATION)
5-24 5-25
55
Dual API Sockets
PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-10614304 Mattox Road • Kansas City, MO 64150 • www.civacon.com
The Convenienceof Dual API Sockets,The Real-WorldReliability of Civacon
Civacon, the name you trust for qualityoverfill prevention system technology,introduces the Dual Face Socket Assembly. Its twoAPI-compatible sockets allow it to interface with anyoptic or thermistor control monitor plugs located atthe loading terminal. When used in conjunction withany truck overfill monitoring system, the Dual Face will transmit the command to shut off the pump incase of an impending overflow condition.
Features• Pre-wired, tested and ready for installation –
long hours of wiring and troubleshooting areeliminated, saving you time and money
• Hard-coated housing, stainless steel hardwareand contacts, and unique moisture evacuatingenclosure design makes it corrosion resistant
• Durable hard-coated aluminum J-Slot wear rings
• Color-coded caps make matching correspondingcolor-coded control monitoring plugs a snap
• Interfaces with either optic or thermistor controlmonitoring plugs
Overfill Prevention Dual Sockets
C40151-THERM Replacement thermistor faceplate
C40151A-OPTIC Replacement optic faceplate
Ordering Specifications
4820R Cable out of the right side4822R With ground wire inside box
4820L Cable out of the left side4822L With ground wire in box
5-24 5-25
55
Single API Socket
PHONE: (816) 741-6600 • (888) 526-5657 • Fax: (816) 741-10614304 Mattox Road • Kansas City, MO 64150 • www.civacon.com
Vehicle-mounted Sockets connect optic,Thermister or Float type level sensors on trailersand truck tanks to compatible control monitorplugs installed at loading terminals. Whenproperly installed, an overfill prevention systemprovides for automatic shutoff of product flow ata predetermined liquid level and warns of animpending overflow condition.
Features• Electrochemical hardcoat finish for long wear.
• Stainless steel contact pins.
• Pin connectors included with all shipments.
• Color coded for easy identification.
• Lightweight, durable, low cost caps with raisedsurfaces for better grip.
• Expanded wire holes for ease of wire/ wire pininstallation.
• Stainless steel hardware.
Ordering SpecificationsSingle API Socket
4100-4100API Pattern Socket (Button) For OpticOutput: Blue Nameplate
4201-4201Scully Pattern Socket (Button) For OpticOutput: Blue Nameplate
4300-4300J560 Pattern Socket (Pin) For OpticOutput: Blue Nameplate
4401-4401API Pattern Socket (Button) ForThermistor Output: Green Nameplate
4500-4500J560 Pattern Socket (Pin) ForThermistor Output: Green Nameplate
4150-4150Replacement Cap and Cable Assembly ForModels 4100-4201: Blue
4450-4450Replacement Cap and Cable AssemblyFor Model 4401: Green
5-28 5-29
55
1 ------ 09132 ---- Cover assembly ( includes items 2 thru 6 ) --------------------------------------------------------------------------- 1 2 ------ 32600 ---- Cover ---------------------------------------------------------------------------------------------------------------------------- 1 3 ------ 32601 ---- Wndow, FM and CSA ------------------------------------------------------------------------------------------------------ 1 4 ------ 31787 ---- Gasket, cover ------------------------------------------------------------------------------------------------------------------ 1 5 ------ 50151 ---- Screw, hex head, 10-24 x 3/4" Stainless steel ------------------------------------------------------------------------ 12 6 ------ 51122 ---- Lockwasher, split, #10, Stainless steel --------------------------------------------------------------------------------- 2 7 ------ 09110 ---- Replacement module, overfill and retained -------------------------------------------------------------------------- 1 ***Options - ( # 09111 ---- Replacement module, overfill only / # 09112 ---- Replacement module, SHO, overfill only ) 8 ------ 32599 ---- Base, 1/2" NPT conduit entries -------------------------------------------------------------------------------------------- 1 9 ------ 31820 ---- Switch assembly, reset ------------------------------------------------------------------------------------------------------ 1
11 ------ 31842 ---- Standoff, male/female, 5/16" hex, 10-32 x 7/8" Lg., Aluminum --------------------------------------------------- 1 ***** 31616 ---- Fuse holder, in-line, 1/2 AMP ( part not shown ) ****** ------------------------------------------------------------ 1
Item Part# Description Qty
/ Scully IntelliCheck2
10 ------ 50740 ---- Pipe plug, plastic, 1/2" NPT ------------------------------------------------------------------------------------------------ 8
5-28 5-29
55
Scully Probes
Item Part # Description Qty 1 ------ 09065 -- SP-MHC (MC) Sensor holder assembly, 1/2" NPT conduit entries (includes items 2 thru 10) - 1 2 ------ 20888 -- Cap, medium height, 2-1/8" (54mm) ----------------------------------------------------------------------------- 1 3 ------ 50652 -- Screw, self-tapping phillips truss head, 10-24 x 1/2", Stainless steel ----------------------------------- 3 4 ------ 51122 -- Lockwasher, split, #10 Stainless steel ------------------------------------------------------------------------- 20 5 ------ 20766 -- O-Ring, Cover, Viton ( registered ) ------------------------------------------------------------------------------ 1 6 ------ 32191 -- Clamp, sensor shaft retaining ------------------------------------------------------------------------------------- 1 7 ------ 22188 -- O-ring, sensor shaft, Viton ( registered ) ----------------------------------------------------------------------- 1 8 ------ 20893 -- Gasket, holder mounting, Viton ( registered ) ---------------------------------------------------------------- 1 9 ------ 57044 -- Mounting nut, holder ------------------------------------------------------------------------------------------------ 110 ------ 50766 -- Pipe plug, plastic, 1/2" NPT ---------------------------------------------------------------------------------------- 111 ------ 28397 -- Cap, sensor wire protector ------------------------------------------------------------------------------------------ 112 ------ 09409 -- Replacement Optic sensor, 7" / 09414 - 12", / 09417 - 15"---------------------------------------------------- 1
5-32 5-33
55
1 ------ 09065 ---------- SP-MHC (MC ) Sensor holder assembly, 1/2" NPT conduit entries ( includes items 2 thru 10 )-- 1Item Part # Description Qty
3 ------- 50652 ---------- Screw, self-tapping phillips truss head, 10-24 x 1/2" Stainless Steel ---------------------------------------- 3
5 ------- 20766 ---------- O-ring, cover, Viton ( registered ) ------------------------------------------------------------------------------------ 16 ------- 32191 ---------- Clamp, sensor shaft retaining ----------------------------------------------------------------------------------------- 17 ------- 22188 ---------- O-ring, sensor shaft, Viton ( registered ) --------------------------------------------------------------------------- 18 ------- 20893 ---------- Gasket, holder mounting, Viton ( registered ) -------------------------------------------------------------------- 1
Scully Probes
10 ------- 50766 --------- Pipe plug, plastic, 1/2" NPT --------------------------------------------------------------------------------------------- 1
4 ----- 51122 ---------Lockwasher, split, #10, Stainless Steel ------------------------------------------------------------- 2
11 ------ 28397 ---------- Cap, sensor wire protector ---------------------------------------------------------------------------------------------- 112 ------ 09209 ---------- Replacement optic sensor, 7" ------------------------------------------------------------------------------------------- 1 09214 ---------- Replacemnt optic sensor, 12" ------------------------------------------------------------------------------------------- 1 09217 ---------- Replacemnt optic sensor, 15" ------------------------------------------------------------------------------------------- 1
9 ------- 57044 --------- Mounting nut, holder ---------------------------------------------------------------------------------------------------- 1
2 ------- 20888 --------- Cap, medium height, 2-1/8' ( 54mm ) -------------------------------------------------------------------------- 1