Doc. code
Quidway S2300/S3300/S5300 Series Ethernet SwitchesV100R005C01SPC100
Upgrade Guide
Issue 01
Date 2011-01-26
HUAWEI TECHNOLOGIES CO., LTD.
Quidway S2300/S3300/S5300 Series Ethernet SwitchesUpgrade Guide Tables
Copyright © Huawei Technologies Co., Ltd. 2011. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd.
Trademarks and Permissions
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS" without warranties, guarantees or representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute the warranty of any kind, express or implied.
Huawei Technologies Co., Ltd.
Address: Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China
Website: http://www.huawei.com
Email: [email protected]
Issue 01 (2011-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
iii
TablesQuidway S2300/S3300/S5300 Series Ethernet Switches
Upgrade Guide
Contents
1 Before You Start.........................................................................2-11.1 Version Requirements Before Upgrade..........................................................................................................2-1
1.2 Impact of Patch Installation............................................................................................................................2-1
1.3 Impact on the System During Installation......................................................................................................2-2
1.3.2 Impact on the System After Installation................................................................................................2-2
1.4 Cautionary Notes Before the Upgrade...........................................................................................................2-2
2 Upgrade Process.........................................................................2-12.1 Upgrade Flowchart.........................................................................................................................................2-1
3 Preparations for Upgrade............................................................3-13.1 Preparation Checklist......................................................................................................................................3-1
3.2 Checking the Current System Software Version............................................................................................3-1
3.3 Checking the Running Status of the Device...................................................................................................3-2
3.4 Setting Up an Environment for the Upgrade..................................................................................................3-2
3.5 Obtaining Required Software for the Upgrade...............................................................................................3-4
3.6 Backing Up the Key Data in the Flash Memory............................................................................................3-4
3.7 Checking the Flash Memory Space................................................................................................................3-6
4 Upgrade Operations on a Single Switch.......................................4-14.1 Upgrading the Switch to V100R005C01SPC100 Using the Command Line................................................4-1
4.2 Upgrading the Switch to the V100R005C01SPC100 Using the BootROM..................................................4-3
4.2.1 Upgrading the BootROM......................................................................................................................4-4
4.2.2 Uploading the System Software............................................................................................................4-7
4.2.3 Specifying the System Software to Be Loaded for Starting the Switch..............................................4-12
4.2.4 Restarting the Switch..........................................................................................................................4-14
4.3 Upgrading the S5300-SI to V100R005C01SPC100 Using the USB Flash Drive........................................4-14
4.3.1 Overview.............................................................................................................................................4-14
4.3.2 Upgrading the Software Using the USB Flash Drive.........................................................................4-14
5 Upgrade Operations on a Stack...................................................5-15.1 Upgrading All Stack Member Switches to V100R005C01SPC100 by Using the Command Line...............5-1
5.2 Using the Intelligent Upgrade Function.........................................................................................................5-4
5.2.1 Overview...............................................................................................................................................5-4
5.2.2 Upgrading a New Member Switch Using the Intelligent Upgrade Function........................................5-5
iv Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
Issue 01 (2011-01-26)
Quidway S2300/S3300/S5300 Series Ethernet SwitchesUpgrade Guide Tables
6 Verifying the Upgrade.................................................................6-16.1 Verification Checklist.....................................................................................................................................6-1
6.2 Checking the Current System Software Version............................................................................................6-1
6.3 Checking the Device Running Status.............................................................................................................6-2
6.4 Checking the System Configuration...............................................................................................................6-2
7 Version Rollback.........................................................................7-17.1 S2300 Version Rollback.................................................................................................................................7-1
7.1.1 Version Rollback Flowchart..................................................................................................................7-1
7.1.2 Loading the Previous System Software................................................................................................7-2
7.1.3 Performing Version Rollback................................................................................................................7-2
7.1.4 Verifying Version Rollback...................................................................................................................7-2
7.2 S3300 Version Rollback.................................................................................................................................7-2
7.2.1 Version Rollback Flowchart..................................................................................................................7-2
7.2.2 Loading the Previous System Software................................................................................................7-3
7.2.3 Performing Version Rollback................................................................................................................7-3
7.2.4 Verifying Version Rollback...................................................................................................................7-3
7.3 S5300Version Rollback..................................................................................................................................7-4
7.3.1 Version Rollback Flowchart..................................................................................................................7-4
7.3.2 Loading the Previous System Software................................................................................................7-4
7.3.3 Performing Version Rollback................................................................................................................7-4
7.3.4 Verifying Version Rollback...................................................................................................................7-4
Issue 01 (2011-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
v
Quidway S2300/S3300/S5300 Series Ethernet SwitchesUpgrade Guide Tables
Figures
Figure 2-1 Upgrade flowchart.............................................................................................................................2-1
Figure 3-1 Network diagram of upgrading the system using TFTP or FTP........................................................3-3
Figure 3-2 Network diagram of upgrading the system using Xmodem..............................................................3-3
Figure 4-1 Flowchart for upgrading the version to the V100R005C01SPC100 using the BootROM................4-4
Figure 7-1 Version rollback flowchart.................................................................................................................7-1
Figure 7-2 Version rollback flowchart.................................................................................................................7-2
Figure 7-3 Version rollback flowchart.................................................................................................................7-4
Issue 01 (2011-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
vii
Quidway S2300/S3300/S5300 Series Ethernet SwitchesUpgrade Guide Tables
Tables
Table 1-1 Version requirements before upgrade..................................................................................................2-1
Table 3-1 Upgrade preparation checklist.............................................................................................................3-1
Table 3-2 Software for different upgrade methods..............................................................................................3-4
Table 4-1 Description of the displayed information..........................................................................................4-13
Table 6-1 Verification checklist...........................................................................................................................6-1
Issue 01 (2011-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
ix
TablesQuidway S2300/S3300/S5300 Series Ethernet Switches
Upgrade Guide
Change History
Changes between document issues are cumulative. The latest document issue contains all the changes in earlier issues.
Issue 01 (2011-01-26)
This issue is the first official release.
x Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
Issue 01 (2011-01-26)
Quidway S2300/S3300/S5300 Series Ethernet SwitchesUpgrade Guide 6 Before You Start
1 Before You Start
1.1 Version Requirements Before Upgrade
Table 1-1 Version requirements before upgrade
Version Upgrade Instruction
S2300, S3300, S5300: V100R002 and earlier versions
The command line of V100R005C01SPC100 is different from the command line of earlier versions. If V100R001 and V100R002 are directly upgraded to V100R005C01SPC100, configurations may be lost. To upgrade V100R001 and V100R002 directly, back up the configuration file first. After the upgrade, compare the new configuration file and the old one to check whether configurations are lost.
It is recommended that you upgrade the version to V100R003 first, and then to V100R005C01SPC100.
S2300, S3300, S5300: V100R003 This version can be upgraded directly to V100R005C01SPC100.
S2300, S3300, S5300: V100R005C00, V100R005C00SPC100, V100R005C01
This version can be upgraded directly to V100R005C01SPC100.
1.2 Impact of Patch InstallationBefore you upgrade an earlier version to the V100R005C01SPC100, read this chapter carefully to understand the possible impacts of the upgrade on the existing system.
Issue 01 (2011-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
1
3 Before You StartQuidway S2300/S3300/S5300 Series Ethernet Switches
Upgrade Guide
1.3 Impact on the System During Installation
Impact on Services
The switch will restart during the upgrade and service will be interrupted.
NOTE
The service interruption time depends on many factors, such as the system software size, upgrade method, operator's skill, and service configurations. The following service interruption time is for your reference:
In the following examples, the switches are not configured and they are not in any stack. In addition, all these switches can provide the PoE function.
If the switches are upgraded by using the BootROM and the system software is uploaded through the serial interface, the service interruption time is as follows (the baudrate is 115200):
S2300: 30 minutes
S3300: 37 minutes
S5300: 44 minutes
If the switches are upgraded by using the BootROM and the system software is uploaded through the network port (FTP mode), the service interruption time is as follows:
S2300: 4.5 minutes
S3300: 4.5 minutes
S5300: 5 minutes
If the switches are upgraded by using the command line, the service interruption time is as follows:
S2300: 2.5 minutes
S3300: 2.5 minutes
S5300: 2.5 minutes
Impact on Network Communication
When the system restarts, the communication between the switch and the NMS is interrupted. The communication interruption time is the same as the service interruption time.
1.3.2 Impact on the System After InstallationThere is no adverse impact on the system.
1.4 Cautionary Notes Before the UpgradeConsider the following cautionary points before performing the upgrade:
The BootROM must be upgraded.
The command lines of the V100R005C01SPC100 version are modified; therefore, after V100R001 or V100R002 is directly upgraded to V100R005C01SPC100, configurations may be lost. After the upgrade, check the configurations manually. It is recommended
2 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
Issue 01 (2011-01-26)
Quidway S2300/S3300/S5300 Series Ethernet SwitchesUpgrade Guide 6 Before You Start
that you upgrade the version to V100R003 first. The upgrade from V100R003 to V100R005C01SPC100 must be performed in the system view. For details on how to upgrade V100R001 or V100R002 to V100R003C00, see the following document:
The flash memory of the S3328/S3352/S2352 can store only one startup file; therefore, delete the current startup file before performing the upgrade. (If there are remaining files in the flash memory, delete them.) The startup file of V100R003 is delete-protected; therefore, you need to load the S23_33_53-V100R003SPH007 to remove the protection. Then you can delete the startup file. You can obtain the S23_33_53-V100R003SPH007.pat file from http://support.huawei.com/support/pages/editionctrl/catalog/ShowVersionDetail.do?actionFlag=getDetail&node=000001447555&colID=ROOTWEB|CO0000000065. After login, fill in the application form. You can download the file after your application is approved. The startup file of V100R005C01SPC100 is not protected, so you do not need to load the patch. The details on how to delete the startup file of V100R005C01SPC100 are described in 3.7 Checking the Flash Memory Space. For details on how to load the patch, see the release notes of the patch.
When you upgrade the software using the command line, stack upgrade, or USB flash drive, do not copy or delete files.
After the version is upgraded, ensure that the configuration is saved because a later version is compatible with early versions but an early version is incompatible with later versions. If the configuration is not saved, the configuration will be lost in the case of version rollback.
When the S2300/S3300/S5300 is upgraded from V100R003 to V100R005C01SPC100, change the DST after the upgrade is successful. If the version is rolled back after the DST is changed, the DST configuration may be lost or incorrect. In this case, you need to reconfigure the DST.
When the S2300/S3300/S5300 V100R005C01SPC100 is rolled back to V100R003, you need to re-set the system time.
When the S2300/S3300/S5300 V100R003 is started in the stack environment, the BootROM is not updated automatically. You must manually upgrade the BootROM. For details on how to upgrade the BootROM manually.
The command line of V100R005C01SPC100 is changed; therefore, compared with the configuration files of V100R003 and earlier versions, the configuration file of V100R005C01SPC100 is changed a lot. The configuration file of V100R005C01SPC100 must begin with the message like "!Software Version V100R005C01SPC100." Before loading the configuration file to V100R005C01SPC100, check whether the configuration file contains the preceding message. If not, the system processes the configuration file in the same way as a V100R003 configuration file. In this case, some configurations may not function properly.
In V100R005, IGMP snooping proxy and VLANIF interface cannot be configured in the same VLAN; however, V100R003 supports the IGMP snooping proxy and VLANIF interface in the same VLAN. If the IGMP snooping proxy and VLANIF interface are configured in the same VLAN in V100R003, the configuration will not be lost after the software is upgraded to V100R005. If you want to re-enable IGMP snooping proxy in the VLAN in V100R005, disable the IGMP snooping proxy, delete the VLANIF interface, and then enable the IGMP snooping proxy again.
Issue 01 (2011-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
3
3 Before You StartQuidway S2300/S3300/S5300 Series Ethernet Switches
Upgrade Guide
If both the system software and patches have been upgraded during the upgrade from an earlier version to V100R005SPC100, delete the $_patchstate_reboot file from the flash memory before reboot.
4 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
Issue 01 (2011-01-26)
Quidway S2300/S3300/S5300 Series Ethernet SwitchesUpgrade Guide 6 Upgrade Process
2 Upgrade Process
2.1 Upgrade Flowchart
Figure 2-1 Upgrade flowchart
Start
Preparation
Upgrade
See chapter 3
See chapters 4 and 5
Verification See chapter 6 Rollback See chapter 7
Yes
YesNo
End
Yes
NOTE
In the following chapters, the version is upgraded to V100R005C01SPC100.
Issue 01 (2011-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
1
Quidway S2300/S3300/S5300 Series Ethernet SwitchesUpgrade Guide 6 Preparations for Upgrade
3 Preparations for Upgrade
3.1 Preparation Checklist
Table 3-1 Upgrade preparation checklist
No. Item Check Point Result
1 Check the system software version
The system software version is between V100R003 and V100R005C01SPC100.
2 Check the running status of the device
The switch functions normally.
3 Set up an environment for the upgrade
An environment is set up for the upgrade as required.
4 Obtain required software for the upgrade
Software required for the upgrade is obtained.
5 Back up the key data in the flash memory
All the key data in the flash memory is backed up.
6 Check the available space in the flash memory
The space in the flash memory is sufficient for storing the system software package and other files such as patch files and configuration files.
In the following sections, the S2300 is used as an example to describe the upgrade.
Issue 01 (2011-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
1
3 Preparations for UpgradeQuidway S2300/S3300/S5300 Series Ethernet Switches
Upgrade Guide
3.2 Checking the Current System Software Version
Run the display version command to view the version of the system software.
<Quidway> display version
Huawei Versatile Routing Platform Software
VRP (R) Software, Version 5.30 (S2300 V100R003C00SPC301)
Copyright (C) 2008-2009 Huawei Technologies Co., Ltd.
Quidway S2318TP-SI uptime is 0 day, 0 hour, 1 minute
[Unit 0] EDFE uptime is 0 day, 0 hour, 1 minute
64M bytes DDR Memory
16M bytes FLASH
Pcb Version : CX22EDFE REV C
Basic BOOTROM Version : 118 Compiled at Nov 4 2009, 17:23:15
Software Version : VRP (R) Software, Version 5.30 (S2300 V100R003C00SPC301)
3.3 Checking the Running Status of the DeviceRun the display device command to check the running status of the switch. If the value of Status is Normal, the device can be upgraded.
<Quidway> display device
Product type: Quidway S2300 Series Ethernet Switches
Memory: 64M bytes DDR
Flash : 16M bytes
Device status :
Unit # Name SubCard # Type Online Status Role
------------------------------------------------------------------------
0 EDFE 0 2318F Present Normal Master
3.4 Setting Up an Environment for the Upgrade
Setting Up an Environment for the Upgrade Using TFTP or FTP
In the BootROM menu or the command line view, you can use the Trivial File Transfer Protocol (TFTP) or File Transfer Protocol (FTP) to download the system software, and set it as the next startup system software. Then restart the device to complete the upgrade. Figure 3-1 shows the network diagram for setting up an environment for the upgrade using FTP or TFTP.
The general requirements for setting up an environment for the upgrade using TFTP or FTP are as follows:
You can log in to the switch from a PC through the serial interface or Telnet.
The server and the switch can communicate with each other.
Files for the upgrade are stored in the server.
2 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
Issue 01 (2011-01-26)
Quidway S2300/S3300/S5300 Series Ethernet SwitchesUpgrade Guide 6 Preparations for Upgrade
Figure 3-1 Network diagram of upgrading the system using TFTP or FTP
In this document, it is assumed that:
The IP address of the Layer 3 service interface of the switch is 1.1.1.1/24.
The IP address of the server is 1.1.1.2/24.
Setting Up an Environment for the Upgrade Using Xmodem
You can upgrade the basic and advanced BootROM software using Xmodem in the basic BootROM menu; you can upgrade the system software using Xmodem in the BootROM menu. Figure 3-1 shows the network diagram for setting up an environment for upgrading the system using Xmodem.
The general requirements for setting up an environment for upgrading the system using Xmodem are as follows:
The RS-232 serial interface on the PC and the console interface on the switch are connected through a console cable.
Files for the upgrade are stored on the PC.
Figure 3-1 Network diagram of upgrading the system using Xmodem
Issue 01 (2011-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
3
3 Preparations for UpgradeQuidway S2300/S3300/S5300 Series Ethernet Switches
Upgrade Guide
3.5 Obtaining Required Software for the Upgrade
To obtain the required software for the upgrade, contact Huawei technical support personnel.
Table 3-1 Software for different upgrade methods
Upgrade Method Matching Software
Upgrading the version to V100R005C01SPC100 using the command line
System software
S2300: S2300-V100R005C01SPC100.CC
S2352: S2352_S3352-V100R005C01SPC100.CC
S3328: S3328-V100R005C01SPC100.CC
S3352: S2352_S3352-V100R005C01SPC100.CC
S5300-EI: S5300EI-V100R005C01SPC100.CC
S5300-SI: S5300SI-V100R005C01SPC100.CC
Upgrading the version to V100R005C01SPC100 using BootROM
BootROM
S2300: bootrom128.bin
S2352: bootrom229.bin
S3328: bootrom330.bin
S3352: bootrom229.bin
S5300-EI: bootrom105.bin
S5300-SI: bootrom126.bin
System software
S2300: S2300-V100R005C01SPC100.CC
S2352:S2352_S3352-V100R005C01SPC100.CC
S3328:S3328-V100R005C01SPC100.CC
S3352:S2352_S3352-V100R005C01SPC100.CC
S5300-EI:S5300EI-V100R005C01SPC100.CC
S5300-SI:S5300SI-V100R005C01SPC100.CC
3.6 Backing Up the Key Data in the Flash Memory
You must back up the key data stored in the flash memory before the upgrade. You can download the data that needs to be backed up to the PC through FTP or TFTP. If the switch functions as the FTP server, see the following steps. If the switch functions as the FTP client or TFTP client, see "FTP and TFTP Commands" in the Quidway S2300/S3300/S5300 Series Ethernet Switches Command Reference – Basic Configurations. After the upgrade, you can reload the backup files to the flash memory.
4 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
Issue 01 (2011-01-26)
Quidway S2300/S3300/S5300 Series Ethernet SwitchesUpgrade Guide 6 Preparations for Upgrade
Step 1 Configure the switch as the FTP server.
Enable the FTP service on the switch, and set the FTP user name to ftpuser and password to ftppwd.
<Quidway> system-view
[Quidway] ftp server enable
[Quidway] aaa
[Quidway-aaa] local-user ftpuser password simple ftppwd
[Quidway-aaa] local-user ftpuser service-type ftp
[Quidway-aaa] local-user ftpuser ftp-directory flash:/
[Quidway-aaa] return
Step 2 Set the switch IP address.
Using the idle service interface is recommended. Here, Ethernet 0/0/1 is taken as an example.
<Quidway> system-view
[Quidway]interface Ethernet 0/0/1
[Quidway-Ethernet0/0/1]port link-type access
[Quidway-Ethernet0/0/1]quit
[Quidway]vlan 10
[Quidway-vlan10] port ethernet 0/0/1
[Quidway-vlan10] quit
[Quidway] interface vlanif 10
[Quidway-Vlanif10] ip address 1.1.1.1 24
[Quidway-Vlanif10] quit
[Quidway]
Step 3 Log in to the FTP server (switch).
NOTE
Assume that the Windows XP operating system is used.
Store the backup file in the specified directory (for example, D:\>directory). Choose Start > Run. Enter cmd and press Enter. Enter FTP 1.1.1.1. Enter the user name at the user prompt and the password at the password prompt, and then press Enter. The following information is displayed:
C:\Documents and Settings\Administrator>d: \
D:\>ftp 1.1.1.1
Connected to 1.1.1.1.
220 FTP service ready.
User (1.1.1.2:(none)): ftpuser
331 Password required for 1.
Password:
230 User logged in.
ftp>
Step 4 Run the get source-filename [ destination-filename ] command on the FTP client (PC) to obtain the file that you want to back up from the FTP server (switch). Here the vrpcfg.cfg file is taken as an example. After downloading the file, run the bye command to close the FTP connection and return to the user view.
ftp> get vrpcfg.cfg
200 Port command okay.
150 Opening ASCII mode data connection for vrpcfg.cfg.
226 Transfer complete.
Issue 01 (2011-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
5
3 Preparations for UpgradeQuidway S2300/S3300/S5300 Series Ethernet Switches
Upgrade Guide
ftp: 2737000.00Kbytes/sec.
ftp> bye
221 Server closing.
D:\>
Step 5 View the backup file on the PC.
----End
3.7 Checking the Flash Memory SpaceStep 1 Run the dir command in the user view to check whether the flash memory space is sufficient
for the system software. If a stack is established, ensure that all the members in the stack have enough space.
The preceding information shows that there is 2,640 KB space. If there is enough space, ignore step 2.
<Quidway> dir
Directory of flash:/
Idx Attr Size(Byte) Date Time FileName
0 -rw- 6,071,492 Jan 08 2008 03:35:29 S2300.cc
1 -rw- 762 Jan 02 2008 02:57:45 vrpcfg.zip
2 -rw- 866 Jan 01 2008 00:00:52 private-data.txt
3 -rw- 6,177,996 Jan 02 2008 02:57:00 s-s2300.cc
14,632 KB total (2,640 KB free)
Step 2 (Optional) Load and activate the patch file S23_33_53-V100R003SPH007.pat.
When the S3300 is upgraded or rolled back to the V100R005C01SPC100, you must delete the startup file because the flash memory space is limited. If the S3300 is upgraded from the V100R005C01SPC100, the startup file is deleted in the same way as common files. If the S3300 is upgraded from the V100R003, you need to load the patch to remove protection of the startup file. Then you can delete the startup file in the same way as common files. The V100R003 upgrade patch file is S23_33_53-V100R003SPH007.pat, which can be obtained from http://support.huawei.com/support/pages/editionctrl/catalog/ShowVersionDetail.do?actionFlag=getDetail&node=000001447555&colID=ROOTWEB|CO0000000065.
After login, fill in the application form. You can download the file after your application is approved. The startup file of V100R005C01SPC100 is not protected, so you do not need to load the patch.
6 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
Issue 01 (2011-01-26)
Quidway S2300/S3300/S5300 Series Ethernet SwitchesUpgrade Guide 6 Preparations for Upgrade
If the system is not installed with any software, do not restart or power off the S3300 until the upgrade is complete. Otherwise, an exception will occur. If the S3300 is powered off during the upgrade, use the BootROM method to upgrade the software. If an exception occurs, contact Huawei technical personnel.
Step 3 Run the delete command to delete unnecessary files to ensure there is enough space for storing relevant upgrade files. Before deleting the unnecessary files, ensure that the files are backed up or are unwanted. The following is an example of deleting the S2300.cc file. For details, see "Managing the File System" in the Quidway S2300/S3300/S5300 Series Ethernet Switches Configuration Guide – Basic Configurations.
After you run the delete /unreserved command to delete a file from the flash, the file cannot be restored; therefore, run this command with caution, and a file backup is recommended.
<Quidway> delete /unreserved S2300.cc
Warning: The contents of file flash:/s2300-v100r003c00spc301b077.cc? cannot be
recycled. Continue? [Y/N]:y
Info: Deleting file flash:/ S2300.cc ...
Deleting file permanently from flash will take a long time if needed.......
................................................................................
................................................................................
................................................................................
................................................................................
................................................................................
................................................................................suc
ceeded.
----End
Issue 01 (2011-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
7
Quidway S2300/S3300/S5300 Series Ethernet SwitchesUpgrade Guide 6 Upgrade Operations on a Single Switch
4 Upgrade Operations on a Single
Switch
4.1 Upgrading the Switch to V100R005C01SPC100 Using the Command Line
The command line upgrade method has little impact on services; therefore, you are advised to upgrade an operating device by using the command line.
Purpose To upgrade the system software
Impact Services are interrupted when the device restarts.
Time Required
In the scenario where a single device is configured and service deployment is simple, services are interrupted about three minutes. In the scenario where service deployment is complicated, the service interruption time increases and the time depends on the complexity of service.
Requirements
The switch that runs system software of an earlier version functions properly.
The available space in the flash memory is sufficient for storing the system software.
Before the S3300 is upgraded, you must delete the original startup file. For details on how to delete the original startup file, see 3.7 Checking the Flash Memory Space.
The methods of upgrading the system software using command line are similar on the S2300, S3300, and the S5300. In the following description, the system software of the S2300 is upgraded.
The following describes only how to download the system software by using the S2300 as the FTP server. For other methods of loading the system software, see the Quidway S2300/S3300/S5300 Series Ethernet Switches Configuration Guide - Basic Configurations.
The S5300 has a dedicated management interface, namely, MEth. The MEth interface can be used as the Layer 3 interface.
Step 1 Configure the S2300 as an FTP server.
Issue 01 (2011-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
1
3 Upgrade Operations on a Single SwitchQuidway S2300/S3300/S5300 Series Ethernet Switches
Upgrade Guide
Start the FTP server on the S2300, and set the FTP user name to ftpuser and password to ftppwd.
<Quidway> system-view
[Quidway] ftp server enable
[Quidway] aaa
[Quidway-aaa] local-user ftpuser password simple ftppwd
[Quidway-aaa] local-user ftpuser service-type ftp
[Quidway-aaa] local-user ftpuser ftp-directory flash:/
[Quidway-aaa] return
Step 2 Set an IP address for the S2300.
Using the idle service interface with default settings is recommended. Here, ethernet 0/0/1 is taken as an example.
<Quidway> system-view
[Quidway]interface ethernet 0/0/1
[Quidway-Ethernet0/0/1]port link-type access
[Quidway-Ethernet0/0/1]quit
[Quidway] vlan 10
[Quidway-vlan10] port ethernet 0/0/1
[Quidway-vlan10] quit
[Quidway] interface vlanif 10
[Quidway-Vlanif10] ip address 1.1.1.1 24
[Quidway-Vlanif10] quit
[Quidway]
Step 3 Log in to the FTP server (the S2300).
NOTE
Assume that the Windows XP operating system is used.
Store the file to be uploaded in the specified directory (for example, D:\>directory). Choose Start > Run. Enter cmd and press Enter. Enter FTP 1.1.1.1. Enter the user name at the user prompt and the password at the password prompt, and then press Enter. The following information is displayed:
D:\>ftp 1.1.1.1
Connected to 1.1.1.1.
220 FTP service ready.
User (1.1.1.2:(none)): ftpuser
331 Password required for 1.
Password:
230 User logged in.
ftp>
Step 4 Upload the system software for the S2300.
Run the put source-filename [ destination-filename ] command on the FTP client (PC) to upload the system software from the PC. After uploading the system software, run the bye command to close the FTP connection and return to the user view.
ftp> put D:\S2300-V100R005C01SPC100.CC
200 Port command okay.
150 Opening ASCII mode data connection for S2300-V100R005C01SPC100.CC.
226 Transfer complete.
ftp: 4940436 bytes sent in 35.10Seconds 140.76Kbytes/sec.
ftp> bye
2 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
Issue 01 (2011-01-26)
Quidway S2300/S3300/S5300 Series Ethernet SwitchesUpgrade Guide 6 Upgrade Operations on a Single Switch
221 Server closing.
D:\>
Step 5 Specify the system software in service, which is loaded when the S2300 is started.
<Quidway> startup system-software S2300-V100R005C01SPC100.CC
If the following information is displayed after you run the startup system-software file command, enter Y to update the BootROM. If the BootROM is upgraded successfully, go to step 7; otherwise, go to step 6. When you upgrade a stack installed with the V100R003 version, you must manually upgrade the BootROM according to step 6.
Warning: Basic BOOTROM will be upgraded. Continue?(Y/N)[N]: y
BOOTROM begin to be upgraded ! please wait for a moment
Info: BOOTROM UPGRADE OK
Succeeded in setting the software for booting system.
Step 6 Upgrade the BootROM in service, which is loaded when the S2300 is started.
<Quidway> system-view
[Quidway] upgrade basic-bootrom S2300-V100R005C01SPC100.CC
Confirm basic BOOTROM will be upgrade?(Y/N)[N]: y
BOOTROM begin to upgraded ! please wait for a minute...
Info: BOOTROM UPGRADE OK
Succeeded in setting the software for booting system.
In the V100R003 and V100R005, the BootROM is upgraded automatically. To upgrade the software to other versions, you must upgrade the BootROM manually. For details about automatic BootROM upgrade, see Step 5.
Step 7 Restart the S2300.
NOTE
After the software is upgraded to V100R005C01SPC100, you must specify the system software for next startup. If the system software is not specified or the invalid software is specified, the device will fail to restart. For details about specifying the system software for next startup, see step 5.
When the system asks you whether to save the configuration, enter y or n. After the setting is complete, enter y to restart the system.
<Quidway> reboot
Info: The system is now comparing the configuration, please wait.
Info: Save current configuration?[Y/N]: y
Now saving the current configuration to the device .
Info: Save the configuration successfully.
System will reboot! Continue?[Y/N]: y
----End
Issue 01 (2011-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
3
3 Upgrade Operations on a Single SwitchQuidway S2300/S3300/S5300 Series Ethernet Switches
Upgrade Guide
4.2 Upgrading the Switch to the V100R005C01SPC100 Using the BootROM
If the BootROM method is used, the services will be interrupted for a long time; therefore, you are advised to upgrade an operating device by using the command line. If the device cannot enter the command line mode, upgrade the device by using the BootROM.
Figure 4-1 Flowchart for upgrading the version to the V100R005C01SPC100 using the BootROM
End
Start
Upgrade BootROM See 4.2.1
Upload systemsoftware
See 4.2.2
Specify startupsoftware
See 4.2.3
Restart the switch See 4.2.4
The methods for upgrading the system software using the BootROM are similar on the S2300, S3300, and the S5300. Here, the method for upgrading the system software on the S2300 is taken as an example.
4.2.1 Upgrading the BootROM
Purpose To upgrade the BootROM
Impact Services are interrupted during the upgrade and the device reboot.
Time Required
The upgrade takes about 100 seconds when the transmission rate of the serial interface is 115200 bit/s.
Prerequisites
After backing up the key data in the flash memory, you must run the reboot command in the user view to restart the system.
4 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
Issue 01 (2011-01-26)
Quidway S2300/S3300/S5300 Series Ethernet SwitchesUpgrade Guide 6 Upgrade Operations on a Single Switch
Do not restart or power off the S2300 when the information "Update BOOTROM system…" is being displayed during the upgrade of the BootROM. Otherwise, the S2300 runs abnormally. In this case, contact Huawei technical personnel.
You can restart or power off the S2300 only when the message "done!" is displayed.
The BootROM menu varies according to the version. Here, the BootROM of V100R005C01SPC100 is taken as an example.
Step 1 Use a serial cable to connect the serial interfaces on the PC and the S2300 and start the HyperTerminal on the PC.
Step 2 Enter the connection name and click OK.
Step 3 Select the serial interface and click OK.
Step 4 On the COM Properties page, click Restore Defaults. Then set the value of Bits per second to 9600 and click OK.
Step 5 If the prompt is displayed on the HyperTerminal, the HyperTerminal is connected to the S2300. In this case, you can upgrade the S2300 using the BootROM.
Step 6 Enter the BootROM menu.
Before entering the BootROM menu, you need to restart the S2300. During the restart of the S2300, the following information is displayed:
Press Ctrl+B to enter BOOTROM menu... 1
Press Ctrl+B before the countdown timer expires, and then enter the password. The default password is huawei or www.huawei.com. Then the advanced BootROM menu is displayed. The following information is displayed:
BOOTROM MENU
1. Boot with default mode 2. Enter serial submenu 3. Enter startup submenu 4. Enter ethernet submenu 5. Enter filesystem submenu 6. Modify BOOTROM password 7. Reboot
Enter your choice(1-7):
Step 7 Enter the BootROM submenu.
Select 2. Enter serial submenu. The following information is displayed:
SERIAL SUBMENU
1. Update BOOTROM system
2. Download file to Flash through serial interface
3. Modify serial interface parameter
4. Return to main menu
Step 8 Modify the parameters of the serial interface.
Issue 01 (2011-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
5
3 Upgrade Operations on a Single SwitchQuidway S2300/S3300/S5300 Series Ethernet Switches
Upgrade Guide
Changing the transmission rate of the serial interface causes interruption of the communication between the PC and S2300. To restore the communication between the PC and the S2300, you must set the transmission rate of the serial interface on the PC the same as that of the serial interface on the S2300.
Select 3. Modify serial interface parameter. The following information is displayed:
Enter your choice(1-5): 3
1: 9600(default)
2: 19200
3: 38400
4: 57600
5: 115200
please select an appropriate baudrate:
Enter your choice(1-5):
Select the transmission rate for the serial interface as required. The transmission rate is expressed in bit/s. The default transmission rate of the serial interface on the S2300 is 9600 bit/s. A greater value you enter represents a higher transmission rate of the serial interface. It is recommended that you enter 5: 115200.
If you change the transmission rate of the serial interface on the S2300, set the transmission rate of the serial interface on the PC the same as that of the serial interface on the S2300. In this manner, you can restore the communication between the PC and the S2300.
For example, after you select 5: 115200, the following information is displayed:
BaudRate is 115200 bps. Please change the terminal's speed to 115200 bps
In this case, you need to perform the following settings on the HyperTerminal of the PC to restore the communication between the PC and the S2300:
On the HyperTerminal, choose Call > Disconnect. The connection is closed
Choose File > Properties. The Properties dialog box is displayed.
On the Connect To tab page, click Configure. The COM Properties dialog box is displayed.
In the Bits per second drop-down list, select 115200.
In the COM Properties and Properties dialog boxes, click OK.
On the HyperTerminal, choose Call > Call. Press Enter. The connection is reestablished.
Step 9 Upgrade the BootROM.
6 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
Issue 01 (2011-01-26)
Quidway S2300/S3300/S5300 Series Ethernet SwitchesUpgrade Guide 6 Upgrade Operations on a Single Switch
The BootROMs for products of various series are incompatible with each other. For example, the BootROM of the S2300 cannot be used to upgrade the BootROM of the S3300; the BootROM of the S3300 cannot be used to upgrade the BootROM of the S2300.
Select 1. Update BootROM system. The following information is displayed:
Enter your choice(1-4): 1
Please Select File .
XMODEM downloading ...CC
Choose Transfer > Send File. The Send File dialog box is displayed.
Click Browse. Then select the bootrom128.bin file for upgrading the BootROM.
Ensure that the selected BootROM file corresponds to the product.
Select XMODEM from the Protocol drop-down list box. Click Send to start sending the file.
After the upgrade file is transferred, the following information is displayed:
XMODEM downloading ...CC download to SDRAM successfully
Warning: Don't Power-off or Reset the Device!!!
Update bootrom system ... done !
Then, the S2300 automatically upgrades the BootROM by using the upgrade file. After the upgrade, the S2300 automatically returns to the BootROM menu.
Step 10 After the BootROM is upgraded, restore the default rates of the serial interface and the HyperTerminal, and then reestablish the connection.
Select 4. Return to main menu in the BootROM menu to return to the BootROM menu, and then select 7. Reboot to reboot the BootROM.
----End
Issue 01 (2011-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
7
3 Upgrade Operations on a Single SwitchQuidway S2300/S3300/S5300 Series Ethernet Switches
Upgrade Guide
4.2.2 Uploading the System Software
Uploading the System Software Through the Serial Interface
Purpose To upgrade the system software
Impact Services are interrupted during the system software uploading and the device reboot.
Time Required
The software uploading time depends on many factors, such as the system software size, transmission rate on the serial interface, and operator's skill. When the transmission rate of the serial interface is 115200 bit/s, the uploading time is about 30 minutes.
Prerequisites
The matched BootROM is upgraded.
The flash memory has enough space to store the system software.
Step 1 Enter the BootROM menu.
When the S2300 is starting, the following information is displayed:
Press Ctrl+B to enter BOOTROM menu... 1
Press Ctrl+B before the countdown timer expires, and then enter the password. The default password is huawei or www.huawei.com. Then the advanced BootROM menu is displayed. The following information is displayed:
BOOTROM MENU
1. Boot with default mode 2. Enter serial submenu 3. Enter startup submenu 4. Enter ethernet submenu 5. Enter filesystem submenu 6. Modify BOOTROM password 7. Reboot
Enter your choice(1-7):
Step 2 Select 2. Enter serial submenu. The following information is displayed:
SERIAL SUBMENU
1. Update BOOTROM system
2. Download file to Flash through serial interface
3. Modify serial interface parameter
4. Return to main menu
Enter your choice(1-4):
Step 3 Modify the parameters of the serial interface.
8 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
Issue 01 (2011-01-26)
Quidway S2300/S3300/S5300 Series Ethernet SwitchesUpgrade Guide 6 Upgrade Operations on a Single Switch
Changing the transmission rate of the serial interface causes interruption of the communication between the PC and S2300. To restore the communication between the PC and the S2300, you must set the transmission rate of the serial interface on the PC the same as that of the serial interface on the S2300.
Select 3. Modify serial interface boot parameter. The following information is displayed:
1: 9600(default)
2: 19200
3: 38400
4: 57600
5: 115200
please select an appropriate baudrate:
Enter your choice(1-5):
Select the transmission rate for the serial interface as required. The transmission rate is expressed in bit/s. The default transmission rate of the serial interface on the S2300 is 9600 bit/s. A greater value you enter represents a higher transmission rate of the serial interface. It is recommended that you enter 5. 115200. If you change the transmission rate of the serial interface on the S2300, set the transmission rate of the serial interface on the PC the same as that of the serial interface on the S2300. In this manner, you can restore the communication between the PC and the S2300.
For example, after you select 5: 115200, the following information is displayed:
BaudRate is 115200 bps. Please change the terminal's speed to 115200 bps
In this case, you need to do as follows on the HyperTerminal of the PC to restore the communication between the PC and the S2300:
On the HyperTerminal, choose Call > Disconnect. The connection is closed
Choose File > Properties. The Properties dialog box is displayed.
On the Connect To tab page, click Configure. The COM Properties dialog box is displayed.
Select 115200bit/s from the Bits per second drop-down list box.
In the COM Properties and Properties dialog boxes, click OK.
On the HyperTerminal, choose Call > Call. The connection is reestablished.
Step 4 Upgrade the system software.
Select 2. Download file to Flash through serial interface in the serial interface submenu, and the following information is displayed:
Enter your choice(1-4): 2
Please Select File .
XMODEM downloading ...CC
Choose Transfer > Send File. The Send File dialog box is displayed.
Click Browse to select the upgrade file of the system software. Then select Xmodem from the Protocol drop-down list box. Click Send to start sending the file.
Issue 01 (2011-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
9
3 Upgrade Operations on a Single SwitchQuidway S2300/S3300/S5300 Series Ethernet Switches
Upgrade Guide
After transferring the upgrade file, the system prompts you whether to change the file name. If no, save it with the default file name. The default file name is not the uploaded file name. The system software name in the flash memory or the default file name hw-switch.cc is used. Generally, it is recommended that the file name be changed.
Only the files with the extension .cc can be used as the upgrade files of the system software on the S2300.
If you need to name the upgrade file S2300-V100R005C01SPC100.CC, the following information is displayed:
XMODEM downloading ...CC download successfully!
Do you like to save it named " S2300-V100R005C01SPC100.CC"?
If you like then press return key, otherwise give a new name for saving it:
S2300-V100R005C01SPC100.CC
If the file S2300-V100R005C01SPC100.CC has already been saved in the flash memory, the system prompts you whether to overwrite the existing file with the new one. The following information is displayed:
flash:/S2300-V100R005C01SPC100.CC already exist,
delete it?(Y/N):y
Deleting file.......................................done
took time : 251s
Writing
Flash..............................................................................
...................................................................................
............done
file length: 6147484 bytes, took time : 144s
SERIAL SUBMENU
1. Update BOOTROM system
2. Download file to Flash through serial interface
3. Modify serial interface parameter
4. Return to main menu
Enter your choice(1-4):
After the upgrade file is transferred, select 4. Return to main menu to return to the BootROM menu.
----End
10 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
Issue 01 (2011-01-26)
Quidway S2300/S3300/S5300 Series Ethernet SwitchesUpgrade Guide 6 Upgrade Operations on a Single Switch
Uploading the System Software Through the Network Port
Purpose To upload the system software
Impact Services are interrupted during the system software uploading and the device reboot.
Time Required
If the system software is uploaded through the FTP or TFTP protocol, the system software uploading time is about one minute.
Prerequisites
The matched BootROM is upgraded.
The flash memory has enough space to store the system software.
The FTP service is enabled on the PC.
Pay attention to the following points:
Select 4. Return to main menu in the BootROM menu to return to the BootROM menu, and then select 7. Reboot to reboot the BootROM. Enter the BootROM menu and load the system software. In addition, specify the software to be loaded in the startup.
Upgrade the system software using the network interface in the BootROM menu.
Step 1 Enter the BootROM menu.
Before entering the BootROM menu, you need to restart the S2300. During the restart of the S2300, the following information is displayed:
Press Ctrl+B to enter BOOTROM menu... 1
Press Ctrl+B before the countdown timer expires, and then enter the password. The default password is huawei or www.huawei.com. Then the advanced BootROM menu is displayed. The following information is displayed:
BOOTROM MENU
1. Boot with default mode
2. Enter serial submenu
3. Enter startup submenu
4. Enter ethernet submenu
5. Enter filesystem submenu 6. Modify BOOTROM password 7. Reboot
Enter your choice(1-7):
Step 2 Select 4. Enter serial submenu. The following information is displayed:
ETHERNET SUBMENU
1. Download file to SDRAM through ethernet interface and boot
2. Download file to Flash through ethernet interface
3. Modify ethernet interface boot parameter
4. Return to main menu
Enter your choice(1-4):
Step 3 Modify the parameters of the network interface.
Issue 01 (2011-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
11
3 Upgrade Operations on a Single SwitchQuidway S2300/S3300/S5300 Series Ethernet Switches
Upgrade Guide
Select 3. Modify ethernet interface boot parameter. The following information is displayed:
BOOTLINE SUBMENU
1. Set TFTP protocol parameters
2. Set FTP protocol parameters
3. Return to ethernet menu
Select TFTP or FTP as required.
For example, the following information is displayed if you select 2. Set FTP protocol parameters. The displayed information cannot be cleared. New settings will overwrite the old settings.
If the TFTP protocol is used, you do not need to enter the user name and password.
'.' = clear field; '-' = go to previous field; ^D = quit
Load File name : S2300-V100R005C01SPC100.CC
Switch IP address : 192.168.1.15:FFFFFF00
Server IP address : 192.168.1.40
FTP User Name : cx
FTP User Password : cx
The fields are described as follows:
Load File name: file name of the startup file to be loaded
Switch IP address: device IP address (the mask is optional)
Server IP address: server IP address
FTP User Name: FTP user name
FTP User Password: FTP password
Step 4 Download the system software.
After network interface parameters are modified, select 3. Return to ethernet menu to return to the Ethernet submenu. Connect the data line to port 1 on the S2300 panel (or connect the data line to the MEth interface of the S5300), and then select 2. Download file to Flash through ethernet interface to load the file. The following information is displayed:
'.' = clear field; '-' = go to previous field; ^D = quit
boot device : et
unit number : 0
processor number : 0
host name : host
file name : S2300-V100R005C01SPC100.CC
inet on ethernet (e) : 192.168.1.15:FFFFFF00
host inet (h) : 192.168.1.40
user (u) : cx
ftp password (pw) : cx
flags (f) : 0x0
Attached TCP/IP interface to mottsec0.
Attaching network interface lo0... done.
Loading...
Read file to sdram .......Done
12 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
Issue 01 (2011-01-26)
Quidway S2300/S3300/S5300 Series Ethernet SwitchesUpgrade Guide 6 Upgrade Operations on a Single Switch
Writing
Flash..............................................................................
.................done
File length: 6177708 bytes
Took time : 33s
After the upgrade file is transferred, select 4. Return to main menu to return to the BootROM menu.
----End
4.2.3 Specifying the System Software to Be Loaded for Starting the Switch
Purpose To specify the system software for next startup
Impact Services are interrupted when you are specifying the system software and the device is restarting.
Prerequisite
The system software to be specified has been downloaded to the flash memory.
Step 1 Specify the system software to be loaded for starting the switch.
After returning to the BootROM menu, select 3. Enter startup submenu to enter the startup submenu. The following information is displayed:
Startup Configuration Submenu
1. Display startup configuration
2. Modify startup configuration
3. Return to main menu
Enter your choice(1-3):
Step 2 Select 2. Modify startup configuration to set the startup mode of the S2300, system software, configuration file, license file, and patch file. The following information is displayed:
Note: startup file field can not be cleared
'.'=clear field; '^D'=quit; Enter=use current configuration
startup type(1: Flash 2: Server)
current: 1
new : 1
Flash startup file (can not be cleared)
current:
new : S2300-V100R005C01SPC100.CC
saved-configuration file
current: vrpcfg.zip
new :
license file
Issue 01 (2011-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
13
3 Upgrade Operations on a Single SwitchQuidway S2300/S3300/S5300 Series Ethernet Switches
Upgrade Guide
current:
new :
patch package
current:
new :
Table 4-1 describes the displayed information.
Table 4-1 Description of the displayed information
Field Description
startup type Startup mode:
1: loads the system software from the flash memory.
2: loads the system software from the server.
Flash startup file System software loaded during the startup. If the system software is loaded from the server, you do not need to set the field.
saved-configuration file Configuration file loaded during startup.
patch package Patch file loaded during startup.
current File that is currently loaded.
new File to be loaded during the next startup.
Startup Configuration Submenu
1. Display startup configuration
2. Modify startup configuration
3. Return to main menu
Enter your choice(1-3):
Step 3 After entering the startup information, select 3. Return to main menu to return to the BootROM menu.
BOOTROM MENU
1. Boot with default mode
2. Enter serial submenu
3. Enter startup submenu
4. Enter ethernet submenu
5. Enter filesystem submenu
6. Modify BOOTROM password
7. Reboot
Enter your choice(1-7):
4.2.4 Restarting the SwitchThe switch is automatically upgraded by loading the latest system software during startup.
14 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
Issue 01 (2011-01-26)
Quidway S2300/S3300/S5300 Series Ethernet SwitchesUpgrade Guide 6 Upgrade Operations on a Single Switch
Enter 7. Reboot on the advanced BootROM menu to restart the switch. Then, the S2300 restores the baud rate on the console interface to 9600 bit/s. The baud rate of the HyperTerminal also needs to be set to 9600 bit/s. The PC then can communicate with the S2300.
4.3 Upgrading the S5300-SI to V100R005C01SPC100 Using the USB Flash Drive
4.3.1 OverviewIf you do not have a PC in the on-site deployment, use the USB flash drive in which the system software and configuration file are stored. The software commissioning engineer is not required.
Only the S5300-SI supports the upgrade in the USB way. The USB flash drive cannot be used for the upgrade of a stack.
The general process of the upgrade in the USB way is as follows:
1. Copy files.
When the S5300-SI is started successfully (the SYS indicator is in green and blinks at 0.5 Hz), the USB flash drive can be inserted to load files. The S5300-SI automatically downloads the system software and configuration file according to the index file in the USB flash drive.
2. Restart the switch.
The S5300-SI sets the system software and configuration file for next startup, and then restarts automatically.
3. Verify the loading of files.
After restarting successfully (the SYS indicator is in green and blinks at 0.5 Hz), the S5300-SI begins to verify the loaded files. When the SYS indicator is in orange and blinks at 0.5 Hz, the upgrade is finished.
4.3.2 Upgrading the Software Using the USB Flash Drive
Preparations for Upgrade1. Prepare the hardware.
USB port: The S5300-SI provides the USB 1.1 port.
USB flash drive:
The USB flash drive delivered with Huawei switch is recommended because this USB flash drive is compatible with the switch. The USB flash drive must be paid independently. If you have not bought the USB flash drive, contact local Huawei office.
The USB flash drive must use the FAT32 format; otherwise, set the format to FAT32 before using it.
Issue 01 (2011-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
15
3 Upgrade Operations on a Single SwitchQuidway S2300/S3300/S5300 Series Ethernet Switches
Upgrade Guide
The space in the USB flash drive must be sufficient for the system software and configuration file.
2. Download the required system software and configuration file.
3. Create the index file.
Step 1: Create the file usbload_config.txt.
Step 2: Fill in the file.
If the index file contains the following two formats, the S5300-SI uses the information in format (2). If the required information is not obtained, the S5300-SI uses the information in format (1).
To write multiple items in the index file, press Enter when you finish each item.
(1) To upgrade the same system software and configuration file on multiple devices, fill in the file in the format <boardtype=s53mv; vrpfile=; cfgfile=; patchfile=;/>.
− boardtype=s53mv is a fixed format, which does not need to be modified.
− Fill in the system software name behind vrpfile=.
− Fill in the configuration file name behind cfgfile=.
− The V100R003 and V100R005 do not support the patch upgrade, so keep patchfile= blank.
Example:
<boardtype=s53mv; vrpfile= S5300SI-V100R005C01SPC100.CC; cfgfile=vrpcfg.cfg;
patchfile=;/>
(2) To upgrade a single device, fill in the file in the format <mac=; vrpfile=; cfgfile=; patchfile=;/>.
− _View the MAC address of the switch on the chassis and add the MAC address behind mac= in the format XXXX-XXXX-XXXX.
− Fill in the system software name behind vrpfile=.
− Fill in the configuration file name behind cfgfile=.
− The V100R003 and V100R005 do not support the patch upgrade, so keep patchfile= blank.
Example:
<mac=0018-8200-0001; vrpfile= S5300SI-V100R005C01SPC100.CC;
cfgfile=vrpcfg1.cfg; patchfile=;/>
<mac=0018-8200-0002; vrpfile= S5300SI-V100R005C01SPC100.CC;
cfgfile=vrpcfg2.cfg; patchfile=;/>
4. Copy the index file, system software, and configuration file to the root directory of the USB flash drive.
16 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
Issue 01 (2011-01-26)
Quidway S2300/S3300/S5300 Series Ethernet SwitchesUpgrade Guide 6 Upgrade Operations on a Single Switch
Do not power off the switch during file copy; otherwise, the upgrade fails or the switch cannot start.
Do not remove the USB flash drive before the upgrade is finished; otherwise, the USB flash drive may be damaged.
Procedure
Step 1 Power on the S5300-SI, and wait until the system completes the startup (you are advertised to wait for two minutes).
Step 2 Confirm that the system is operating stably (the SYS indicator is in green and blinks every two seconds). If the system operating is unstable, wait or solve the issue.
If the SYS indicator is on and in green or orange, the system startup is not finished. Wait until the system starts successfully.
If the SYS indicator is on and in red, the system is started but an error occurs. Fix the problem before the next step. Check whether the power supply and the fan function properly. If no, power off the S5300-SI, and then restart the S5300-SI. If the fault persists (the indicator is on and in red), contact Huawei technical support personnel.
Step 3 Insert the USB flash drive.
If the SYS indicator is in green and blinks more than twice every second, the system is copying the system software and configuration file from the USB flash drive.
After copying the files, the system restarts.
If the SYS indicator is in orange and blinks every two seconds after the restart, the upgrade is successful. Now you can remove the USB flash drive.
If the SYS indicator is on or blinks in red, or blinks and is in read, an error occurs. Power off the S5300-SI and power on it, and then insert the USB flash drive again. If the upgrade fails three times, check whether the index file on the USB flash drive is correct, or contact the Huawei technical support personnel.
----End
Issue 01 (2011-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
17
Quidway S2300/S3300/S5300 Series Ethernet SwitchesUpgrade Guide 6 Upgrade Operations on a Stack
5 Upgrade Operations on a Stack
5.1 Upgrading All Stack Member Switches to V100R005C01SPC100 by Using the Command Line
Purpose To upgrade all stack member switches to V100R005C01SPC100 by using the command line
Impact Services are interrupted when the devices restart.
Time Required
When a single device is upgraded and service deployment is simple, services are interrupted about 3 minutes. When a stack is upgraded, the service interruption time increases, and the time depends on the complexity of services and the stack.
Prerequisites
The devices to be upgraded function properly.
The flash memory has enough space to store the system software.
The methods of for upgrading the system software of the S3300 and the S5300 using the command line interface are similar. Here, the S3300 is used as an example.
The section describes only how to download the system software by using the S3300 as the FTP server. For other methods of loading the system software, see the Quidway S3300/S5300 Series Ethernet Switches Configuration Guide - Basic Configurations.
The S5300 provides a management interface MEth. You can use this interface as a Layer 3 interface.
To retain the roles of the master and slave devices after the upgrade, set priority of the master switch to be the highest in the stack before the upgrade.
Issue 01 (2011-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
1
3 Upgrade Operations on a StackQuidway S2300/S3300/S5300 Series Ethernet Switches
Upgrade Guide
When the S3300 is upgraded or rolled back to the V100R005C01SPC100, you must delete the startup file because the flash memory space is limited. If the S3300 is upgraded from the V100R005C01SPC100, the startup file is deleted in the same way as common files. If the S3300 is upgraded from the V100R003, you need to load the patch to remove protection of the startup file. Then you can delete the startup file in the same way as common files. The V100R003 upgrade patch file is S23_33_53-V100R003SPH007.pat, which can be obtained from http://support.huawei.com/support/pages/editionctrl/catalog/ShowVersionDetail.do?actionFlag=getDetail&node=000001447555&colID=ROOTWEB|CO0000000065.
After login, fill in the application form. You can download the file after your application is approved. The startup file of V100R005C01SPC100 is not protected, so you do not need to load the patch.
The following operations are performed on the master switch. Here, the stack contains two member switches.
Step 1 Delete the current startup software package.
<Quidway> delete /unreserved flash:/S2352_S3352-V100R005C00SPC100.cc
Info: This is Next startup system software. If you delete it, there is no software
to reboot successfully! Confirm to delete the file? [Y/N]:y
Warning: The contents of file flash:/S2352_S3352-V100R005C00SPC100.cc cannot be
recycled. Continue? [Y/N]:y
Info: Deleting file flash:/S2352_S3352-V100R005C00SPC100.cc...
Deleting file permanently from flash will take a long time if
needed.............................................................................
...................................................................................
....................................................succeeded.
<Quidway> delete /unreserved slot1#flash:/S2352_S3352-V100R005C00SPC100.cc
Info:This is Next startup system software. If you delete it, there is no software
to reboot successfully!Confirm to delete the file? [Y/N]:y
Warning: The contents of file slot1#flash:/S2352_S3352-V100R005C00SPC100.cc cannot
be recycled. Continue? [Y/N]:y
Info: Deleting file slot1#flash:/S2352_S3352-V100R005C00SPC100.cc...
Deleting file permanently from flash will take a long time if
needed.............................................................................
...................................................................................
..................................................................................s
ucceeded.
In the S3300 V100R003, the software package of the slave switch is saved in the path unitX#flash:. For example, if the current software package is S2352_S3352-V100R003C00SPC301.cc, run delete /unreserved unit1#flash:/S2352_S3352-V100R003C00SPC301.cc to delete the software package from the slave switch.
Step 2 Configure the switch as the FTP server.
Enable the FTP service on the switch, and set the FTP user name to ftpuser and password to ftppwd.
<Quidway> system-view
[Quidway] ftp server enable
[Quidway] aaa
2 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
Issue 01 (2011-01-26)
Quidway S2300/S3300/S5300 Series Ethernet SwitchesUpgrade Guide 6 Upgrade Operations on a Stack
[Quidway-aaa] local-user ftpuser password simple ftppwd
[Quidway-aaa] local-user ftpuser service-type ftp
[Quidway-aaa] local-user ftpuser ftp-directory flash:/
[Quidway-aaa] return
Step 3 Configure an IP address for the switch.
Configure the IP address on an idle interface. Here, ethernet 0/0/1 is used as an example.
The interface Ethernet 0/0/1 and port link-type access commands must be run in the V100R005C01SPC100, but are not required in the V100R003.
<Quidway> system-view
[Quidway]interface Ethernet 0/0/1
[Quidway-Ethernet0/0/1]port link-type access
[Quidway-Ethernet0/0/1]quit
[Quidway] vlan 10
[Quidway-vlan10] port ethernet 0/0/1
[Quidway-vlan10] quit
[Quidway] interface vlanif 10
[Quidway-Vlanif10] ip address 1.1.1.1 24
[Quidway-Vlanif10] quit
[Quidway]
Step 4 Log in to the FTP server (the switch).
Assume that the Windows XP operating system is used.
Store the file to be uploaded in the specified directory (for example, D:\>directory). Choose Start > Run. Enter cmd and press Enter. Enter FTP 1.1.1.1. Enter the user name at the user prompt and the password at the password prompt, and then press Enter. The following information is displayed:
D:\>ftp 1.1.1.1
Connected to 1.1.1.1.
220 FTP service ready.
User (1.1.1.2:(none)): ftpuser
331 Password required for 1.
Password:
230 User logged in.
ftp>
Step 5 Upload the system software to the switch.
Run the put source-filename [ destination-filename ] command on the FTP client to upload the system software. After system software is uploaded to the switch, run the bye command to close the FTP connection and return to the user view.
ftp> put D:\S2352_S3352-V100R005C01SPC100.CC
200 Port command okay.
150 Opening ASCII mode data connection for S2352_S3352-V100R005C01SPC100.CC.
226 Transfer complete.
ftp: 4940436 sent in 35.10Seconds 140.76Kbytes/sec.
ftp> bye
221 Server closing.
Issue 01 (2011-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
3
3 Upgrade Operations on a StackQuidway S2300/S3300/S5300 Series Ethernet Switches
Upgrade Guide
D:\>
Step 6 Specify the uploaded software as the next startup software.
<Quidway> startup system-software S2352_S3352-V100R005C01SPC100.CC all
If the following information is displayed after you run the startup system-software file command, enter y to upgrade the BootROM.
Warning: Basic BOOTROM will be upgraded. Continue?(Y/N)[N]: y
BOOTROM begin to be upgraded ! please wait for a moment
Info: BOOTROM UPGRADE OK
Info: Succeeded in setting the software for booting system on 0.
100% complete\
Info: Copied file flash:/s2352_s3352-V100R005C01SPC100.cc to
slot1#flash:/s2352_s3352-V100R005C01SPC100.cc...Done.
Info: Succeeded in setting the software for booting system on 0.
Info: Succeeded in setting the software for booting system on 1.
If the current version is V100R003, the all keyword is not required. That is, you can upgrade all the member switches by using the startup system-software S2352_S3352-V100R005C01SPC100.cc command.
Step 7 Restart the switch.
After the software is upgraded to V100R005C01SPC100, you must specify the system software for next startup. If the system software is not specified or the invalid software is specified, the device will fail to restart. For details about specifying the system software for next startup, see step 5.
When the system asks you whether to save the configuration, enter y or n. After the setting is complete, enter y to restart the system.
<Quidway> reboot
Info: The system is now comparing the configuration, please wait.
Info: Save current configuration?[Y/N]: y
Now saving the current configuration to the slot 0 .
System will reboot! Continue?[Y/N]: y
----End
5.2 Using the Intelligent Upgrade Function
5.2.1 OverviewIntelligent upgrade is a function that automatically upgrades or rolls back the system software of a new member switch to the version of the master switch.
A stack system is established only when all the following requirements are met:
All the member switches use the same software version. If the master switch detects a different software version on the new member switch, it upgrades or rolls back the software of the new member switch to the version of the stack.
4 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
Issue 01 (2011-01-26)
Quidway S2300/S3300/S5300 Series Ethernet SwitchesUpgrade Guide 6 Upgrade Operations on a Stack
The S3352 supports a maximum of eight switches in a stack system. The other S3300 models and the S5300 support up to nine switches in a stack system.
The S3352 and S3328 cannot be added to the same stack system.
All the member switches belong to the same series. That is, the EI series and SI series cannot form a stack.
All the member switches are connected by using stack cables and stack modules.
All the member switches are working properly.
The stacking function is enabled on all the member switches.
The stack processes version upgrade and rollback for new member switches in the same way.
5.2.2 Upgrading a New Member Switch Using the Intelligent Upgrade Function
Preparations for Upgrade
Before upgrading a new member switch of a stack, ensure that:
The new member switch and the current stack members belong to the same series.
The new member switch is connected to other member switches by using stack cables and stack modules.
The stacking function is enabled on the new member switch. (This function is enabled by default.)
If the flash memory of the new member switch does not have sufficient space to store the startup software package, the switch automatically deletes a software package to free up the space. If the switch is an S5300, it deletes a non-startup software package. If the switch is an S3300, it deletes the current startup software package. If the available space in the flash memory is still insufficient for the upgrade software, the switch restarts repeatedly. In this case, upgrade the software of the switch to the version of the stack system manually, and then add the switch to the stack. For the upgrade procedure, see 4 Upgrade Operations on a Single Switch.
The S3300s in a stack system cannot be upgraded from V100R003 to V100R005C01SPC100 by using the method described in this chapter. To upgrade the S3300s in a stack system, use the command line interface (see 4.1 Upgrading the Switch toV100R005C01SPC100 Using the Command Line) or the NMS Data Center (DC) (see the Quidway S2300&S3300&S5300 V100R005 DC Upgrade Guide).
During the upgrade, ensure that the stack cables are functioning properly. If the upgrade of a switch fails, manually upgrade the system software of the switch to the version of the stack system, and then add the switch to the stack system.
Upgrade Process
Start the new member switch.
Issue 01 (2011-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
5
3 Upgrade Operations on a StackQuidway S2300/S3300/S5300 Series Ethernet Switches
Upgrade Guide
The master switch of the stack automatically upgrades the new switch. If the upgrade is successful, the following information will be displayed:
On the master switch:
In Stack, device 0 load to new device 1 .......... start
In Stack, device 0 load to new device 1 .......... success
On the new member switch:
My Software Version is Low!
100% completed
In Stack, device 0 load flash:/S5300EI-V100R005C01SPC100.CC to new device
1(self) ... Success
Starting upgrade BOOTROM .............. Pass
Device starting reset.
If the flash memory of the new member switch does not have sufficient space for the upgrade software, the following information is displayed:
On the master switch:
In Stack, device 0 load to new device 1 .......... start
In Stack, device 0 load to new device 1 .......... fail
On the new member switch:
In Stack, upgrading from slot 4 to slot 0(self) .......... start
Info: Free space is not enough. Auto deleting <flash:/s_s3328_b023.cc> file ....
................................................................................
........................... success
100% completed
In Stack, upgrading from slot 4 to slot 3(self) ... succeed
Upgrading BOOTROM .............. Pass
In this case, manually upgrade the system software of the switch to the version of the stack system, and then add the switch to the stack system. For details, see 4.1 Upgrading the Switchto V100R005C01SPC100 Using the Command Line or 4.2 Upgrading the Switch to the V100R005C01SPC100 Using the BootROM.
6 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
Issue 01 (2011-01-26)
Quidway S2300/S3300/S5300 Series Ethernet SwitchesUpgrade Guide 6 Verifying the Upgrade
6 Verifying the Upgrade
6.1 Verification Checklist
Table 6-1 Verification checklist
No. Item Criteria Result
1 Check the current system software version
The system software version is V100R005C01SPC100.
2 Check the device running status
The device runs properly.
3 Check the system configuration
The system configuration is correct.
6.2 Checking the Current System Software Version
Run the display version command to view the version of the system software running on the S2300.
<Quidway> display version
Huawei Versatile Routing Platform Software
VRP (R) software, Version 5.70 (S2300 V100R005C01SPC100)
Copyright (C) 2003-2010 HUAWEI TECH CO., LTD
Quidway S2318TP-SI Routing Switch uptime is 0 week, 0 day, 0 hour, 1 minute
EDFE 0(Master) : uptime is 0 week, 0 day, 0 hour, 0 minute
64M bytes DDR Memory
16M bytes FLASH
Pcb Version : VER C
Basic BOOTROM Version : 124 Compiled at Jun 5 2010, 16:56:15
Software Version : VRP (R) Software, Version 5.70 (S2300 V100R005C01SPC100)
Issue 01 (2011-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
1
3 Verifying the UpgradeQuidway S2300/S3300/S5300 Series Ethernet Switches
Upgrade Guide
6.3 Checking the Device Running StatusRun the display device command to check the switch running status. Normal indicates that the device functions properly.
<Quidway> display device
S2318TP-SI's Device status:
Slot Sub Type Online Power Register Status Role
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
0 - 2318F Present PowerOn Registered Normal Master
6.4 Checking the System ConfigurationUse the display current-configuration command to check the system configuration. Check whether the system software version is V100R005C01SPC100 (V100R005C01SPC100 is taken as an example and the actual version number depends on the released version) and whether the configuration is restored (the following configuration is taken as an example).
The configuration file may be modified after the upgrade. For the command line changes, see the release notes of the matching version.
<Quidway>display current-configuration
#
!Software Version V100R005C01SPC100
sysname Quidway
#
vlan batch 1
#
cluster enable
ntdp enable
ntdp hop 16
ndp enable
#
dhcp enable
#
undo http server enable
#
drop illegal-mac alarm
#
aaa
authentication-scheme default
authorization-scheme default
accounting-scheme default
domain default
domain default_admin
local-user admin password simple admin
local-user admin service-type http
#
2 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
Issue 01 (2011-01-26)
Quidway S2300/S3300/S5300 Series Ethernet SwitchesUpgrade Guide 6 Version Rollback
7 Version Rollback
7.1 S2300 Version RollbackIf an error occurs after the upgrade, perform version rollback to restore normal service operating.
7.1.1 Version Rollback Flowchart
Figure 7-1 Version rollback flowchart
End
Start
Load previoussoftware package
See 7.1.2
Perform version rollback See 7.1.3
Verify version rollback See 7.1.4
Issue 01 (2011-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
1
3 Version RollbackQuidway S2300/S3300/S5300 Series Ethernet Switches
Upgrade Guide
There are great differences between the BootROM of S2300 V100R005C01SPC100 and the BootROM of V100R002; therefore, the version can only be rolled back to a released version of S2300 V100R003. To roll back the version to V100R002 or a version earlier than V100R002, roll back the version to V100R003C00SPC301 first.
Note:
1. Only the configuration file in cfg format can be used for rollback. Before performing the rollback operation, check the format of the configuration file. If the configuration file is not in cfg format, save it as a cfg format.
2. An S2300-SI with PCB version C or D cannot be returned to V100R002. You can use the display version command to view the PCB version of the device.
3. When the S2300/S3300/S5300 V100R005C01SPC100 is rolled back to V100R003, you need to re-set the system time.
7.1.2 Loading the Previous System SoftwareThe procedure for loading the previous system software package is the same as the procedure for loading the system software for the upgrade. For details, see Upgrading the Switch to V100R005C01SPC100 Using the Command Line.
7.1.3 Performing Version RollbackThe version rollback method is the same as the version upgrade method. For details, see Upgrading the Switch to V100R005C01SPC100 Using the Command Line.
7.1.4 Verifying Version RollbackThe verification of version rollback is the same as the verification of version upgrade. For details, see Verifying the Upgrade.
2 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
Issue 01 (2011-01-26)
Quidway S2300/S3300/S5300 Series Ethernet SwitchesUpgrade Guide 6 Version Rollback
7.2 S3300 Version Rollback
7.2.1 Version Rollback Flowchart
Figure 7-1 Version rollback flowchart
End
Start
Load previoussoftware package
See 7.2.2
Perform version rollback See 7.2.3
Verify version rollback See 7.2.4
There are great differences between the BootROM of S3328 V100R005C01SPC100 and the BootROM of earlier versions; therefore, the version can be rolled back to only a released version of S3328 V100R003. The version must be rolled back to the V100R003C00SPC301, and then rolled back to an early version.
Note:
1. When the S3328 V100R005C01SPC100 is rolled back to the S3328 V100R003C00SPC301, the output information may be different from the normal output information displayed during upgrade.
2. Only the configuration file in cfg format can be used for rollback. Before performing the rollback operation, check the format of the configuration file. If the configuration file is not in cfg format, save it in cfg format.
3. When the S2300/S3300/S5300 V100R005C01SPC100 is rolled back to V100R003, you need to re-set the system time.
7.2.2 Loading the Previous System SoftwareThe procedure for loading the previous system software package is the same as the procedure for loading the system software for the upgrade. For details, see Upgrade Operations on a Single Switch or Upgrade Operations on a Stack.
Issue 01 (2011-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
3
3 Version RollbackQuidway S2300/S3300/S5300 Series Ethernet Switches
Upgrade Guide
7.2.3 Performing Version RollbackThe version rollback method is the same as the version upgrade method. For details, see Upgrade Operations on a Single Switch or Upgrade Operations on a Stack.
7.2.4 Verifying Version RollbackThe verification of version rollback is the same as the verification of version upgrade. For details, Verifying the Upgrade.
7.3 S5300Version Rollback
7.3.1 Version Rollback Flowchart
Figure 7-1 Version rollback flowchart
End
Start
Load previoussoftware package
See 7.3.2
Perform version rollback See 7.3.3
Verify version rollback See 7.3.4
When the S5300 V100R005C01SPC100 is rolled back to the S5300 V100R003, pay attention to the following point:
Only the configuration file in cfg format can be used for rollback. Before performing the rollback operation, check the format of the configuration file. If the configuration file is not in cfg format, save it in cfg format.
When the S2300/S3300/S5300 V100R005C01SPC100 is rolled back to V100R003, you need to re-set the system time.
4 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
Issue 01 (2011-01-26)
Quidway S2300/S3300/S5300 Series Ethernet SwitchesUpgrade Guide 6 Version Rollback
7.3.2 Loading the Previous System SoftwareThe procedure for loading the previous system software package is the same as the procedure for loading the system software for the upgrade. For details, see Upgrade Operations on a Single Switch or Upgrade Operations on a Stack.
7.3.3 Performing Version RollbackThe version rollback method is the same as the version upgrade method. For details, see Upgrade Operations on a Single Switch or Upgrade Operations on a Stack.
7.3.4 Verifying Version RollbackThe verification of version rollback is the same as the verification of version upgrade. For details, see Verifying the Upgrade.
Issue 01 (2011-01-26) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.,
Ltd
5