SALT SPRAY.CYCLIC CORROSION TESTING.
Good engineering is a pre-requisite for reliability
PAGE 5PAGE 4
SALT SPRAY.CYCLIC CORROSION TESTING.
Features Specification Benefits
Hood Large acrylic translucent hood.Pneumatic cylinder assisted operation.
Easy viewing of the specimen under test.Easy loading & unloading of test specimen.
Chamber StructureMoulded fibre reinforced plastic.Coated with automotive PU paints.
Non-Corrosive.Long life.Better aesthetics.
Leveling Casters
50mm wheel with high quality ABS resin handle. Easily movable.Anti-vibration function.High abrasion resistance.High chemical resistance.
Features Specification Benefits
Operational5.7” TFT touch screen with PLC.Ethernet and USB interface.
High control accuracy.Pre-loaded major test standards.Easy to download test data.
Safety Alarm
Solution level.Saturator water level.Humidity tank water level.Wick water level.Air pressure.Chamber temperature.Saturator temperature.Humidity tank temperature.Conditioning unit temperature.
Protects the chamber from any deviation from the set value.
Features Specification Benefits
AtomiserProduces 500micron droplet size.Acrylic body .Easy to dis-assemble.
Uniform fog collection.Easy maintenance.
Peristaltic PumpDC motor with drive.4 contact rollers .Isoprene tube.
Non-contact dosing of solution.Continuous duty cycle.
Angle Rack & Hanging Rods FRP slotted angle rack as per standard (15o inclination).
Easy mounting of test specimen.Maximum exposure while testing.
Remote Fall Out Fog Collector Graduated jar connected through a PU tube from a 80 Sqcm funnel placed inside the test space.
Measure the fall out rate periodically without interrupting tests.
Humidity & Conditioning Unit Low pressure vapour boiler with air circulator. Controlled injection of moisture with ± 3% fluctuation.
CONSTRUCTION
OPERATIONAL
PERFORMANCE
FEATURES & BENEFITS
Humidity & Conditioning Unit Atomiser Envicom Controller
PAGE 7PAGE 6
SALT SPRAY.CYCLIC CORROSION TESTING.
Parameter JASO M610 Requirement JASO M610 SF-CCT Compliance Performance (Maximum Test Time Saved)
Ambient to 35oC NA 11 min
Salt Spray at 35oC / 45oC saturator 120 min 120 min -
35oC to 60oC and 20oC <30 Min 8 min 22 min
Soak at 60oC and 20%RH 240 min 240 min -
60oC 20%RH to 50oC 95%RH <15 Min 7 min 8 min
Soak at 50oC 95%RH 120 min 120 min -
50oC 95%RH to 35oC <30 min 26 min 4 min
Salt Spray at 35oC/45oC Saturator 120min 120min -
Total 34 min
JASO M610 - REQUIREMENT
JASO M610- SF-CCT COMPLIANCE
PERFORMANCESF-CCT Capability
CME firmly believes that, its offering must exceed customer expectations.
Our chambers meet all renowned international test standards such as ASTM, ISO, DIN, JASO and 150 others! In our SF-CCT range of chambers, the cyclic tests such as Salt Spray, Wetting, Drying and Humidity control can be achieved without the use of a refrigeration system, decreasing the power consumption.Performance must speak for itself and this is shown in the below graph of JASO M610, performed by our chamber.
For a normal 10 cycle JASO test, CME chamber saves test time of 5h 40’.
PAGE 9PAGE 8
SALT SPRAY.CYCLIC CORROSION TESTING.
HIGH HUMIDITY CYCLE
SF-CCT range of chambers are compatible to multiple test standards, including automotive standards and it can be alternated / cycled between varied humidity programs with traditional salt spray.
Bottom fog collectors1, 2, 3 & 4
Top fog collectors5, 6, 7 & 8
Remote fog collector9
Start Temperature Set Value TimeAmbient 60oC / 25%RH 27 min
60oC 50oC / 60%RH 8 min
50oC 50oC / 70%RH 3 min
50oC 50oC / 80%RH 3 min
50oC 50oC / 95%RH 6 min
100mm
100mm 100mm
100mm
100mm100mm
100mm 100mm
200mm
2
1
6
5 8 4
7 3
9
Sl. No. Cham. Temp Satu. Temp Air Pres-sure
Standard for collectors in ml per 12 hour Requirement
Drive speed 1 2 3 4 1 to 2ml per hour in 80 cm²area
1 350C 450C 14 psi 1.5 19.2 20.4 19.2 21.6
Sl. No. Cham. Temp Satu. Temp Air Pres-sure
Standard for collectors in ml per 12 hour Requirement
Drive speed 5 6 7 8 1 to 2ml per hour in 80 cm²area
2 350C 450C 14 psi 1.5 19.8 21 19.8 21
FOG COLLECTION
PAGE 11PAGE 10
SALT SPRAY.CYCLIC CORROSION TESTING.
Test StandardStandardorigin industry/country
Type of tests (Standard chamber) Type of test (with/optional accessory)
Solutionspray
Dry cycle
HighHumidity
Water fog
Condensa-tion test
Sprayheader
Immer-sion
Air conditioningo unit (25 to 10 C)
Dehumidifier
Noxious gas dozing
Wall wash
Type ofchamber
Prohesion American 0 0 CCT
ASTM B-117 American 0 Both
ASTM D-1735 American 0 Both
ASTM D-2247 American 0 CCT
ASTM G43 American 0 0 # CCT
ASTM G44 American 0 0 CCT
ASTM G5894 American 0 0 # CCT
ASTM G85, Annex 1 American 0 Both
ASTM G85, Annex 2 American 0 0 0 CCT
ASTM G85, Annex 3 American 0 0 # CCT
ASTM G85, Annex 4 part 1 American 0 0 CCT
ASTM G85, Annex 4 part 2 American 0 0 0 CCT
ASTM G85, Annex 5 American 0 0 # CCT
MIL STD 202F American Military 0 Both
MIL STD 810E American Military 0 0 Both
MIL STD 750 American Military 0 Both
GM 4298P American 0 Both
GM 4465P American 0 Both
GM 9540P American CCT
BS 2011 Part 2.1 British 0 Both
BS 3900 F2 British 0 # Both
BS 3900 F4 British 0 0 CCT
BS 3900 F12 British 0 Both
BS 5466 P1 British 0 Both
BS 5466 P2 British 0 Both
BS 5466 P3 British 0 Both
DEF 0755 (DEF 133) British 0 0 # CCT
BS 7479 British 0 Both
BS-EN-ISO 4541 British 0 0 CCT
BS-EN-ISO 7253 British 0 Both
BS-EN-60068-2-11 British 0 Both
BS-EN-6052-11-6 British 0 Both
BS-EN-60068-2-52 British 0 0 # CCT
BS-EN-60512-11-6 British 0 Both
NFX 41-002 French 0 Both
DIN 50 017KK German 0 CCT
DIN 50 017KFW German 0 0 CCT
DIN 50 017KTW German 0 0 0 CCT
DIN 50 021 SS German 0 Both
DIN 50 021 ESS German 0 Both
DIN 50 021 CASS German 0 Both
VG 95210 German 0 Both
VDA 621-421 German 0 CCT
VDA 621-415 German 0 0 0 0 CCT
ISO 3768 Europe 0 Both
Test StandardStandardorigin industry/country
Type of tests (Standard chamber) Type of test (with/optional accessory)
Solutionspray
Dry cycle
HighHumidity
Water fog
Condensa-tion test
Sprayheader
Immer-sion
Air conditioningo unit (25 to 10 C)
Dehumidifier
Noxious gas dozing
Wall wash
Type ofchamber
ISO 3769 Europe 0 0 CCT
ISO 3770 Europe 0 Both
ISO 7253 Europe 0 Both
ISO 9227 Europe 0 CCT
ISO 14993 Europe 0 0 0 # CCT
CCT I (CCT A) Europe 0 0 0 # CCT
CCT II (CCT B) Europe 0 0 0 # CCT
CCT IV (CCT D) Europe 0 0 0 Both
SAE J-2334 Europe 0 0 0 # CCT
ISO 6270-2 (AHT) Europe 0 0 CCT
ISO 6270-2 (CH) Europe 0 CCT
IEC 68-2-11-P2 Europe 0 CCT
IEC 68-2-52-P2 Europe 0 0 # CCT
ISO 6270-2 (AT) Europe 0 0 0 Both
ISO 16701 Europe 0 0 0 Both
ISO 16701 Europe 0 0 Both
AA0324 (AA-P 184) BMW 0 Both
AA0213 (AA-P 224) BMW 0 CCT
AA0224 (AA-P 175) BMW 0 0 CCT
50180 A1 Fiat 0 Both
AS 2331 Method 3.3 Australia 0 Both
AS 2331 Method 3.3 Australia 0 0 0 CCT
AS 2331 Method 3.13-B Australia 0 0 # CCT
AS 2331 Method 3.13-C Australia 0 0 0 0 0 CCT
AS 2331 Method 3.13-E Australia 0 0 0 0 CCT
D171058 Renault 0 Both
D172028 Renault 0 0 0 # 0 0 CCT
ECC - 1 Renault 0 0 0 # 0 0 CCT
JASOM609 Japan 0 0 0 # # CCT
JASOM610 Japan 0 0 # CCT
JISH8502 M1 Japan 0 Both
JISH8502 M2 Japan 0 Both
JISH8502 M3 Japan 0 Both
JISH8502 M4 Japan 0 CCT
JISH8502 M5 Japan 0 0 CCT
JISZ2371 Japan 0 Both
JNS30.16.03 Jaguar 0 Both
P-V W-1210 VW 0 0 0 0 0 CCT
P-V W-1209 VW 0 0 0 0 0 CCT
RTCA/DO-160 RTCA Inc 0 Both
STD1027,14 Volvo 0 0 0 # 0 0 CCT
VCS1027,149 Volvo 0 0 0 0 0 CCT
VCS1027,1449 Volvo 0 0 0 0 CCT
FLTMB1 103-01 Ford 0 Both
CETP 00.00-L-467 Ford 0 0 0 0 CCT
TEST STANDARDSCompliance of SF-SST and SF-CCT Models
The test that the standard demands 0Can be provided based on customer requirement #
The test that the standard demands 0Can be provided based on customer requirement #
Only can be done in CCT chamber CCTCan be performed by both basic and CCT chamber Both
Only can be done in CCT chamber CCTCan be performed by both basic and CCT chamber Both
PAGE 13PAGE 12
SALT SPRAY.CYCLIC CORROSION TESTING.
Models
SF-570-SST SF-570-CCT SF-960-SST SF-960-CCT SF-1850-SST
SF-1850-CCT
SF-3710-SST
SF-3710-CCT
Salt Spray Chamber
Cyclic Cor-rosion Test Chamber
Salt Spray Chamber
Cyclic Cor-rosion Test Chamber
Salt Spray Chamber
Cyclic Cor-rosion Test Chamber
Salt Spray Chamber
Cyclic Cor-rosion Test Chamber
Test Space Dimensions with Hood W x D X H mm
800 x 500 x 1090(570 Ltrs) 850 x 700 x 1365(960 Ltrs) 1600 x 700 x 1440(1850 Ltrs) 2000 x 1200 x 1440(3710 Ltrs)
Test Space Dimensions without Hood W x D X H mm
800 x 500 x 550(250 Ltrs) 800 x 700 x 800(450 Ltrs) 1600 x 700 x 800(895 Ltrs) 2000 x 1200 x 800(2000 Ltrs)
External Dimensions W x D X H mm
1975 x 900 x 1250
1975 x 1200 x 1250
2025 x 1100 x 1650
2025 x 1400 x 1650
2775 x 1100 x 1750
2775 x 1400 x 1750
3100 x 1600 x 1750
3100 x 1900 x 1750
Solution Reservoir (L) 60 120 120 120
Power Supply Voltage and Frequency dependent on country of installation
Electric Phase 1 or 3 dependent on country of installation
Maximum Connected Load 3 KW, 12A 4KW, 16A 3 KW, 12A 5KW, 16A 4.5KW, 18A 6KW, 32A 5KW, 20A 8KW, 32A
Controller PID Micro Controller
Envicom Touchscreen Controller
PID Micro Controller
Envicom Touchscreen Controller
PID Micro Controller
Envicom Touchscreen Controller
PID Micro Controller
Envicom Touchscreen Controller
Test Space Load Bearing Capacity 200 Kg UDL 250 Kg UDL 250 Kg UDL 300 Kg UDL
Temperature Range
Ambient to 55°C
Ambient to 70°C
Ambient to 55°C
Ambient to 70°C
Ambient to 55°C
Ambient to 70°C
Ambient to 55°C
Ambient to 70°C
Temperature Fluctuation ± 1°C
Humidity Range NA 25% to 98% RH NA 25% to 98%
RH NA 25% to 98% RH NA 25% to 98%
RH
Humidity Fluctuation NA ± 3% RH NA ± 3% RH NA ± 3% RH NA ± 3% RH
Chamber Construction Fibre Reinforced Plastic, Acrylic & Nylon
Hood Pneumatic operated
Solution and air tubing Poly-urethane tube
Fog Fall Out Rate 0.5 to 2.5ml/80cmsq/h
Spray Mechanism Acrylic atomiser
Sound Level 50dbA
Removable Angle Racks 1 x 16 slots (15 Deg inclination)
Specimen Hanging Rods 6 FRP Rods
Water DM Water, pH 5-8, 1-3Kg/cm2
Water Connection 8x6mm PU quick connector
Air Clean, Dry and Oil free 4-6 Kg/cm2, 300LPM
Air Connection 8x6mm PU quick connector
Air Exhaust Connection 72mm, BSP Thread to be terminated outside building
Drain Connection 25mm, BSP Thread, to be terminated at floor level drain
TECHNICAL SPECIFICATION INSTALLATION DIAGRAM
ISOMETRIC VIEW SIDE VIEW
D
FRONT VIEW
400 400W
1 3
2
4
H
TOP VIEW
W
1 3
2
4
1000
1000
1205enviCoM
MENU
PWR
PAGE 15PAGE 14
SALT SPRAY.CYCLIC CORROSION TESTING.
CUSTOMER SUPPORTCentral to the success of our company
Through a combination of chamber diagnostics, preventive maintenance and remote monitoring, we ensure uninterrupted operation of the chamber.
CHAMBER DIAGNOSTICSelf-Troubleshoot
Chamber Diagnostic Tool
PREVENTIVE MAINTENANCEPhone, Web & Email Support
+91 888 000 7700 / [email protected]
REMOTE MONITORINGEnvicom Controller
Internet
GLOBAL SERVICE & SUPPORTComprehensive & Preventive Maintenance Contracts
OPTIONAL ACCESSORIES
AIR COMPRESSOR CODE SF-0010.75HP Oil free reciprocating air cooled low noise air compressorAir receiver capacity: 25 LitersMax Pressure – 8 Kg/cm2 and fitted with auto cut-off and pressure gauge.Air Outlet will be provided with a Ball Valve and 8x6mm PU Tube Connector.
WATER DE-IONIZER CODE SF-002Provides Water of suitable purity to run the chamber with a continuous water supply.Min operating pressure: 2Kg/cm2Vessel Size: (155 Dia x 595 H)mm
IMMERSION CYCLE CODE SF-003Temperature Range: 50oCA pre-heated reservoir tank where the inner and outer material will be FRP molded and coated with high resistance vapor based plastic coating.The solution will be automatically pumped into the test space.Water float switches will maintain the level in the test space.Solution can be pumped back into the reservoir and also drained out.Capacity: 600 Liters Inner Dimension:(1000W x 800D x800H) mm Exterior Dimension: (1100W x 900D x 1000H) mmPower Supply: 230V AC, +10%, 1Phase, 50Hz + Earth.Max Connected Load: 3 KW
SPRAY HEADER CYCLE CODE SF-004A solution spray header consisting of multiple spray nozzles will be provided.The nozzles are adjustable and can be directed towards the test specimen.The salt solution from the tank is pumped through a high capacity centrifugal pump.This test can be conducted for a maximum of 10 min with the in-built solution tank. Additional capacity tank can be opted for in optional (SF-005). Max Connected Load: 0.5 KW.
ANGLE RACKS CODE SF-010Slotted angle racks of 3mm will be provided at an angle of 15o from vertical
ACCESS PORT CODE SF-008Standard silicone access port of 125 mm diameter with an insulated silicone plug
PAGE 16
CM Envirosystems Pvt. Ltd.KIADB Industrial Area, Plot No.18 & 19, 1st Main, 1st Cross, Dabaspet,Nelamangala Taluk, Bangalore - 562111, India.+91 88800 07700 . Fax +91 80 2773 4010 . www.cmenvirosystems.com
CME is now present in 4 continents (Asia, Europe, North America and Latin America) and 24 countries.
CME is one of the fastest growing Environmental Test Chamber manufacturers in the world.Spread over 18,500 sqm state of the art manufacturing facility is a green building with over 40% of green cover, making the work atmosphere stress free, efficient and productive.The company is ISO 9000:2008 certified.