Rishabhdev-KRishabhdev-KRishabhdev-KRishabhdev-KRishabhdev-KometometometometometPVC Telephone CablesUnarmoured / Armoured
TEST VOLTAGE : 2 KVCONDUCTOR : PLAIN / TINNED COPPERINSULATION : PVCINNER SHEATH : EXTRUDED / WRAPPED PVCOUTER SHEATH : PVCCONSTRUCTIONNO. OF PAIRS : 1 - 100CONDUCTOR DIA : 0.50 / 0.60 / 0.71
RISHABHDEV KOMET TELEPHONE & SWITCHBOARD CABLES
RTL twisted paired cables are best suited for telephone and switchboard cabling applications. The conductor is made of solid annealed, high conductivitybare copper with nominal diameter of 0.5 mm. The conductor is insulated with special grade high-density polyethylene with different colours. Theinsulated cores are twisted with uniform lay to form pairs and are bunched together in such a manner so as to minimise cross talk. The laid up cables aretaped with polyester and further jacketed with a grey colour fire retardant PVC with high oxygen index and temperature index, specially formulated andmanufactured in-house. They are recommended for switchboard and internal telephone wiring in high-rise buildings, offices, factories, hotels, residentialcomplexes, etc. The cables generally conform to ITD specifications S/WS 113C and RTL specifications.
Stringent quality control is exercised at every stage, from raw material through manufacturing, upto the finished stage which guarantees high quality.
Salient Features : l Low attenuation l Low cross talk l Fire Retardant Jacket
CONSTRUCTION PARAMETERS 1 PAIR 2 PAIR 3 PAIR 4 PAIR 5 PAIR
Conductor Solid annealed bare copper, 0.5 mm diameter (nom.)
Insulation Material High density polyethylene
Insulation Thickness Average 0.20 mm
Diameter of Insulated Conductor Maximum 0.92 mm
Rip cord Nylon
PVC Jacket FRPVC compound with high oxygen index
Approx. Outer diameter 2.75 mm 3.50 mm 4.00 mm 4.70 mm 5.50 mm
Colour Combination
Pair 1 White - Blue White - Blue White - Blue White - Blue White - Blue
Pair 2 - White - Orange White - Orange White - Orange White - Orange
Pair 3 - - White - Green White - Green White - Green
Pair 4 - - - White - Brown White - Brown
Pair 5 - - - - White - Grey
ELECTRONIC PARAMETERS
Conductor Resistance Max. 92.20 Ohms/Km at 200C
Mutual Capacitance Max. 50 nf/Km
Insulation Resistance in Air Min. 10000 M-Ohms/Km
Capacitance Unbalance Pair to Pair Max. 250 pF/Km
21
Rishabhdev-KRishabhdev-KRishabhdev-KRishabhdev-KRishabhdev-Kometometometometomet
RISHABHDEV CO-AXIAL CABLES
Rishabhdev co-axial cables, used for Cable TV Network, are the best that money can buy. Each feature is specially designed to give you the benefit. Theinner conductor is made of electrolytic grade copper, drawn in-house on modern machines. The low loss, special grade polyethylene foam is insulationcompound is extruded on sophisticated machines. The double screen (laminated AI tape and AI wire braid) ensures low loss transmission and clearreception. This is most evident in areas with high concentration of electromagnetic signals. The double screen offers better attenuation values thancables with single screening. Higher bandwidth, which means more than 50 channels. Excellent adhesion of dielectric to conductors, as well as bondedaluminium foil to dielectric does not allow moisture to enter the cables. This makes it ideal for tropical conditions.
Stringent tests & checks at every stage, from RM, through Mfg. up to the finished product High quality standards expected of every RTL product.
Special Features :l High bandwidthl Low attenuation values.l Minimum structural return loss.l Low loss in signal quality.l Ideal for power pass applications.
Construction Cable Type
Parameters RG 11 F RG 6 F RG 59 F
Inner Conductor Solid Bare Solid Bare Solid BareCopper Copper Copper
Nom. Dia (mm) 1.63 1.02 0.80
Dielectric Foam PE Foam PE Foam PENom. Dia (mm) 7.11 4.57 3.55
Outer Conductor
FIRST Bonded Bonded BondedAI Tape AI Tape AI Tape
SECOND AI Braid AI Braid AI BraidNom. Coverage (%) 60 60 60
Jacket PVC PVC PVC(Black) (Black) (Black)
Nom. Dia (mm) 10.2 7.2 6.00
Electrical Parameters Cable Type
RG 11 F RG 6 F RG 59 F
Inner ConductorMax. Resistance (Ohm/km) at 200C 8.50 21.00 35.00Loop Resistance (Ohm/km) at 200C 16.80 28.50 46.43
Nom. Capacitance (pF/mtr.) 53 53 53
Nom. Impedance (Ohm) 75 75 75
Nom. Velocity Ratio (%) 85 85 85
Nom. Attenuation at 250C (dB/100m)at 5 MHz 1.50 2.08 2.82
55 MHz 3.60 5.30 6.7383 MHz 4.32 6.40 8.04187 MHz 6.40 9.40 11.81211 MHz 6.80 9.95 12.47250 MHz 7.37 10.85 13.40300 MHz 8.12 11.85 14.60350 MHz 8.77 12.80 15.75400 MHz 9.42 13.70 16.73450 MHz 9.95 14.50 17.72500 MHz 10.56 15.35 18.70550 MHz 11.00 16.05 19.52600 MHz 11.60 16.90 20.34750 MHz 13.05 18.95 22.871000 MHz 15.50 22.05 26.64
22
Rishabhdev-KRishabhdev-KRishabhdev-KRishabhdev-KRishabhdev-KometometometometometELASTOMERIC CABLES
Description Conductor Voltage Range SpecificationGrade
Welding Plain OR Tinned Copper : Upto 16-95 Sq. mm IS : 9857 / 1990Cables Annealed Copper 1.1 KV Aluminium : Upto 25-120 Sq. mm
Aluminium
Elastomeric Tinned Annealed 1.1 KV 1 Core = 0.5 to 630 Sq. mm IS : 9968Cables Copper 2 Core = 0.5 to 240 Sq. mm (Part - I) / 1988
3 Core = 0.5 to 150 Sq. mm4 Core = 0.5 to 120 Sq. mm5 Core = 0.5 to 16 Sq. mm1 to 61 Core = 0.5 to 2.5 Sq. mm
Lift Annealed Tinned 1.1 KV 6 to 30 Core = 0.75 to 1.0 Sq. mm IS : 4289CABLES Copper (Part - I ) / 1984
23
SPECIALITIES(i) High Temperature operation.(ii) Flexibility over wide range of temperature.(iii) Moisture Resistance.(iv) Corrosion Resistance.(v) Resistance to ozone and sunlight.(vi) Radiation resistance.(vii) Excellent electrical properties.(ix) High thermal resistivity.
APPLICATIONS
Silicone rubber insulation has excellent electrical properties & high thermalresistance. It allows conductor temperature rating of 1500C for continuousoperation & 2500C under emergency overload & 3500C during shortcircuit. It maintains circuit continuity even in fire because silicone rubberburns into an insulating ash. It is resistant to moisture, ozone radiation &chemicals. Being elastometric in nature it is flexible & flexibility is retainedover wide range of temperature (+2000C to -550C)
l Blast furnaces & Coke ovens.l Steel Mills & EoT crane.l Nuclear & Thermal Power Stations.l Electric Furnaces & Boilers.l High temperature metallurgical plants e.g. Alloy Steel.l Cell Room of Aluminium Extraction Plant etc.l High Frequency generator.l Electrical Machineries for Class B, F and H service.l Airport lighting or other high wattage lighting units.
CONSTRUCTION, VOLTAGE GRADE, SIZE,RANGE AND SPECIFICATIONS
CONSTRUCTION
Single Core cable
Annealed tinned copper or aluminium conductor, insulated with siliconerubber and finally glass fibre braided and varnished.
Rishabhdev-KRishabhdev-KRishabhdev-KRishabhdev-KRishabhdev-Kometometometometomet
SILICONE CABLES
SILICONE RUBBER INSULATED SINGLE CORE CABLE
Area in Conductor Bunched Max. DC Insulation Cable OD Currentsqmm Const. in mm app Resist Thickness in mm app Rating
0.5 16 x 0.2 0.94 39 0.6 2.2 40.75 24 x 0.2 1.2 26 0.6 2.5 71 32 x 0.2 1.34 19.5 0.6 2.6 11
1.5 48 x 0.2 1.64 13.3 0.6 2.9 1430 x 0.25
2.5 60 x 0.2 1.64 13.3 0.6 2.9 1450 x 0.25
4 56 x 0.3 2.61 4.95 0.8 4.3 266 84 x 0.3 3.5 3.013 1 5.6 31
10 80 x 0.4 4.6 1.86 1 6.7 4216 124 x 0.4 5.9 1.15 1.2 8.4 5725 200 x 0.45 7.6 0.6911 1.4 10.5 7135 280 x 0.45 8.7 0.5277 1.4 11.6 9150 396 x 0.4 10.6 0.3572 1.6 13.9 12070 360 x 0.5 12.3 0.2639 1.6 15.5 16195 475 x 0.5 14.7 0.204 1.8 18.5 200
120 608 x 0.5 16.7 0.153 2 20.9 225150 943 x 0.5 18.3 0.123 2 22.5 240185 925 x 0.5 20 0.101 2.2 24.6 300240 1221 x 0.5 23 0.0763 2.2 27.6 425
24
Multicore Cable
Cores constructed as single core cable, distinguishingly colour codedand laid up circular with asbestos layer & finally glass braided withvarnished or Asbestos braided and compounded.
Cables with other protective finish such as silicone or CSP sheath, wirebraid or single Wire or double armour also can be supplied.
VOLTAGE GRADE
Usually 600/1000 volts but cables or higher voltage also can be supplied.
SIZE RANGE
Upto & including 500sq.mm for 1 core & 300sq. mm for multicore cables.
SPECIFICATIONS
Generally to IS: 1968, BS: 6007, BS: 6195, BS: 6500 and also to customer'sspecifications.
HIGH TECHNOLOGY CABLES
HI - TEMP Cablesl Constant Voltage Cables l Silicone rubber flat has heating cables.l PTFE/FEP/ETFE Dielectric l Custom designed cables.
Rishabhdev TRishabhdev TRishabhdev TRishabhdev TRishabhdev Technocable Ltd.echnocable Ltd.echnocable Ltd.echnocable Ltd.echnocable Ltd.
PVC & XLPE LT POWER CABLESRishabhdev Technocable Ltd. is manufacturing LT Power Cables with PVC or XLPE insulation of voltage grade upto 3.3 KV conforming to various Indianand International Standard Specifications. RTL also manufactures other types of cables as listed at the end of this catalogue.
CROSS LINKED POLYETHYLENE (XLPE)XLPE means cross-linked polyethylene or vulcanized polyethylene. The basic material is low density polyethylene. Polyethylene is a thermoplasticmaterial consisting of long chain of hydrocarbon molecules. At elevated temperatures these molecules tend to move relative to one another so that thematerial becomes increasingly deformable and will eventually melt at the temperature around 1100C.
By means of process similar to the vulcanization of rubber the polyethylene molecules can be cross-linked. The process of cross-linking or vulcanizationconsists of producing chemical bonds at interval between the long molecular chain to give a �Ladder� effect which prevents slippage between molecules.As a result of cross-linking the material becomes heat resistant and does not soften at higher temperatures. Further it has better resistances to stresscracking and good resistance to ageing in hot air. With the change of structure there is no adverse effect on electrical properties.
Advantages of �RTL�� XLPE CABLES4 Dielectric losses are very small.
4 Higher current carrying capacity.
4 Higher short circuit rating 2500C. as against 1600C for PVC.
4 RTL XLPE can retain flexibility down upto - 400C.
4 Jointing and Termination is easy.
4 Light in Weight
4 They are not prone to fatigue damages due to vibrations or loadings cycles.
4 Has better resistances to most chemicals, oils, acdis, etc.
4 Can be installed along cable routes without elevation limitations.
Characteristics Unit PVC XLPE
Permittivity (50Hz, 200C) -- 4 - 6 2.3
Dielectric Loss Factor (50Hz, 200C) _ 0.05 - 0.07 0.0004
Volume Resistivity (200C) ohms cm (min.) 1013 1016
Max. Conductor Temp. 0C 70 90
Max. Short Circuit Temp. 0C 160 250
Tensile Strength N / mmm2 (min.) 160 250
Elongation at break -- Excellent Medium
Flexibility at-100 C -- Poor Good
Resistance to abrasion -- Medium Good
COMPARISON OF MAIN PROPERTIES BETWEEN PVC AND XLPE INSULATION
f
26
Properties & Advantages of Rishabhdev Cables
1. A basic advantage of Rishabhdev is that insulationresistance and breakdown strength are practicallyunaffected by moisture. In fact, Rishabhdev cable mayeven be laid directly under water.
2. Rishabhdev cables may be over loaded for shortperiods without any effect on cable life.
3. Since there is no impregnating compound in thesecables, they can be laid vertically and on steep slopes.Further, there is no danger of bleeding at lower levelsealing ends.
4. Rishabhdev cables have high short circuit safety sincethey can withstand a high transient conductortemperature without any deformation of insulation ordisplacement of conductors.
5. Rishabhdev cables are resistant to practically allchemicals encountered in practice. Most of thecommon acids, alkalies and saline solutions have noeffect on Rishabhdev.
6. Rishabhdev cables are flame retardant sinceRishabhdev ignites with great difficulty and that toowhen directly exposed to a flame. It does notpropagate the flame. Rishabhdev extinguishes itselfas soon as the source of fire is removed.
7. Due to their light weight, Rishabhdev cables are easyto install and handle. Besides, there is a saving incable supports. Small bending radii permit thetermination of these cables in limited space. This easesthe termination of Rishabhdev cables in switchboardsand control panels.
8. Low tension Rishabhdev cables do not require sealingends when installed indoors, hence termination isdone quickly and economically.
9. Rishabhdev cables have a smooth outer surfaceresulting in a neat appearance when installedRishabhdev outer sheath is tough and abrasion proof.
10.Rishabhdev cable have a long service life.
RTL Power & Control Cables in switch yard
RTL Power & Control Cables on cables racks.
RTL Control Cables in control panel
27
TESTThe test detailed below prove the superiority of RTL FRLS cables over general purposes PVC cables
under conditions of fire. The tests are as per international specifications.
Test Specification Function FindingGeneral FRLS PVCPurpose PVC
Critical ASTM-D-D2863 To determine percentage of oxygen required Oxygen required Oxygen requiredOxygen Index to support combustion at room temperature. 23% >29%
Temperature ASTM-D-D2863 To determine at what temperature normal Maximum TemperatureIndex Oxygen content of 21% in air will support temperature >2500C
combustion. 1200C
Smoke ASTM-D2843/77 To determine the percentage of density Smoke density Smoke densityGeneration of smoke generated by the PVC jacket 80% <60%
over the cable under fire condition.
Acid gas IEC754-1 To determine the percentage of hydrochloric Hydrochloric acid Hydrochloric acidGeneration acid released from the PVC jacket over released released< 20%
the cable. >26%
Flammability IEEE 383 To determine the extent of flame propagation Flame spreads Flame spreadstest on in 20 minutes, under specified flaming over entire 1.8 for a maximum offinished conditions, for a cable sample of 1.8 meters meter length 0.6 meterscable length.
Flammability Swedish To determine ignition resistance and flame Complete burning Unburnt portiontest class SS4241475 propagation under specified conditions of 850 mm length more than 300mmFII for a cable sample of 850 mm length.
AG Acid gas generation as per IEC-754-1 Flammability test as per IEEE 383
28
No Smoking
CriticalZone
General Construction
Conductors
The conductors of power cables are normally made fromelectrical purity aluminium and those of control cablesare of annealed high conductivity copper. However,copper conductor power cable can also be suppliedagainst orders. All conductors conform to IS:8130.
Normally, aluminium conductors up to size 10sq. mm.are solid, circular in cross section, and sizes above10sq.mm. are stranded. In case of single core and twincore cables they are circular in cross section while for 3core and 4 core cables, conductors of cross section 25sq.mm. and above are normally sector shaped.
Insulation : The conductors are insulated with the highquality Rishabhdev PVC base compound.
Core identification
Colour Scheme : Cores are identified by colourscheme of PVC insulation. The following colourscheme is adopted :-
1 Core- Red, Black, Yellow or Blue2 Core - Red and Black3 Core - Red, Yellow and Blue4 Core - Red, Yellow, Blue and Black(also 3 1/2 core) (reduced neutral core is black)5 Core - Red, Yellow, Blue, Black and light Grey
For cables having more than 5 cores:
Two adjacent cores (counting and directional) in 4 eachlayer are coloured Blue and Yellow respectively and theremaining cores are light Grey.
Inner Sheath: for all cables having two or more cores, acommon covering (inner sheath) is applied over the laidup cores either by extruded sheath of un-vulcanisedrubber compound or wrapping of plastic or proofed tapes.Single core cables do not have inner sheath.
Armouring : Armouring is applied over the inner sheath.In case of cables where diameter over the inner sheathdoes not exceed 13 mm., the armour consists ofgalvanised round steel wires; above this size, normallythe armour is of galvanised flat steel wires (strips).
Armouring of Rishabhdev mining cables consists ofgalvanised round steel wires / strips, but wherevernecessary, a few tinned copper wires/strips are alsoincluded to meet the conductance requirements ofarmouring for mining cables as specified in DGMS letterNos. E(Hq)/43/1374 dated 27-10-1971 and43/1516/EHQ dated 11-10-1972.
Outer Sheath : Over the armouring, or in case ofunarmoured cables, over the inner sheath (for single corecables over the insulation) a tough outer sheath ofRishabhdev is extruded. This is always black in colour,for best resistance to outdoor exposure.
The manufacturers� name and trade mark �RTL - KOMETRishabhdev along with the year / year code ofmanufacture are embossed on the outer sheath;additionally in the case of LT cables, the word �ELECTRIC�and in the case of HT cables, the voltage grade is alsoembossed. In the case of Rishabhdev mining cables,the word MINING is added in the embossing script. Theembossing script repeats in such a way that every meterof the cable bears the same script.
Type designation : Type designation of Rishabhdevcables is based on the following alphabeticalnomenclature:
A - Aluminium conductors - When first letter oftype designation. When type designationdoes not contain �A� in the beginning, thencable is with copper conductors.
Y - When at first or second place in typedesignation it stand for PVC insulation.
CE - Individual core screening.W - Round steel wire armouringF - Flat steel wire (strip) armouring.Gb - Steel tape counter helix.Y - When last in type designation , it stands forPVC outer sheath.
Conductor Types:
re - Circular, solid conductorrm - Circular, stranded conductor.rm/v - Circular, stranded compacted conductor.sm - Sector shaped, stranded conductor.
Number of cores, conductor cross section, voltagegrade are written in the usual manner.
Example
Ayfy 3 x 400 sm 650/1100 V
Aluminium conductor, PVC insulated, flat steel wire (strip)armoured, PVC overall sheathed 3-core-cable, conductorsize 400 sq.mm. stranded sector shaped 650/1100Vgrade.
YY 37 x 1.5 re 650/1100 V
copper conductor, PVC insulated and PVC sheath.(Unarmoured) 37 core cable, conductor size 1.5 sq. mm.solid round 650/1100 V grade.
29
FIELD OF APPLICATION
Rishabhdev - Komet Control Cables 650/ 1100V as per IS (Part 1) - 1976Type and Construction Application
Rishabhdev Komet Power Cable 650/1100V as per IS : 1554 (Part I) - 1976
Type AYYUnarmoured Multicore cables withAluminium conductors up to 500 sq.mm.
Type AYYUnarmoured Single core cable withAluminium conductors up to 1000 sq.mm.
Type YWY/YFYArmoured 1.5 and 2.5 sq. mm.Copper conductors up to 61 cores
Type YYUnarmoured 1.5 and 2.5 sq. mm.Copper conductors up to 61 cores
These cables are suitable for control purposes ormeasuring circuit, in generating stations, sub-stations,industrial installations, etc., as well as for railwaysignalling. They can be installed indoors or outdoors, inair or in cable ducts.
These cables are suitable for control purposes ormeasuring circuits in generating stations, sub-stations,industrial installations, etc., as well as for railwaysignalling. On account of the armouring, the cables cabwithstand rough installation and operation conditions andtensile stresses. These can be laid in water or burieddirect in the ground even on steep slopes. They can alsobe installed indoors or outdoors, in air or in cable ducts.
Light weight and small permissible bending radii makesingle core Rishabhdev cables very easy to install. Thesecables are therefore particularly useful in power stationsand sub-stations where a comparatively large number ofcables in short lengths are to be used.
These power cables are suitable for use in generatingstations, sub-stations, house-service connections,street lighting, industrial installations, building wiring,etc. They can be installed indoors or outdoors,in air or in cable ducts.
Rishabhdev Komet Power Cable 650/1100V as per IS : 1554 (Part I) - 1976
Type and construction Application
F
F
F
F
30