Edwards Protection Cannulae
RetrogradeCardioplegia Catheters
MAXIMIZE MYOCARDIAL PROTECTIONA growing body of evidence points to combined retrogradeand antegrade cardioplegia as the best approach formaximizing myocardial protection in patients undergoingarrested heart procedures.1-5
Edwards retrograde cardioplegia catheters are specificallydesigned to help you protect your patients during on-pumpcardiac surgery by maximizing myocardial protection.
Edwards retrograde cardioplegia catheters offer a varietyof features designed to meet various surgical needs andpreferences.
Proprietary ergonomichandle provides an
anatomically precise pathduring placement
AR05171_EDW_Spec_Cardio_Retro_1.qxd:Layout 1 6/21/10 3:47 PM Page 2
SELF-INFLATING BALLOONEdwards retrograde cardioplegia catheters are available in a self-inflating balloon style, which offersthe convenience of automatic balloon inflation when retrograde cardioplegia is delivered.
Balloon Styles: Balloon Sizes:Available in textured and Multiple balloon sizes ranging from 9 mm to 20 mm tosmooth balloon configurations. accommodate a variety of patient sizes and surgical preferences.
RetrogradeCardioplegia Catheters
Multiple handle and styletoptions to accommodate a variety
of surgical preferences
* Shorter length† Female luer instead of stopcock
Smoothballoon
Texturedballoon
Pre-shapedstylet and
handle
Hourglasshandle andguidewire
styletGuidewirestylet
SPECIFICATIONSCATHETER SIZE 9 FR 12 FR 14 FRBALLOON STYLE Smooth Textured Textured SmoothBALLOON SIZE 9 mm 18 mm 14 mm 18 mm 20 mm 18 mm 20 mmRETENTION Conventional Retractaguard Conventional Retractaguard Conventional Retractaguard Conventional Conventional ConventionalTECHNOLOGY technology technology technologyPRE-SHAPED RC09 RC2012 RC014IT RC2014 RC014T RC2014LB NPC014T RC014 NPC014STYLET AND RC2014S* RC2014LBS*HANDLEGUIDEWIRE RC09M RC2012M - RC2014M RC014MT RC2014LBM - RC014M -STYLET ISP3031†
HOURGLASS - - - ISP3098 - - - - -HANDLE ANDGUIDEWIRESTYLETH
AN
DLE
CON
FIG
URA
TIO
NS
AR05171_EDW_Spec_Cardio_Retro_1.qxd:Layout 1 6/21/10 3:47 PM Page 3
MANUALLY INFLATING BALLOONEdwards retrograde cardioplegia catheters are available in a manually inflating balloon style,which offers surgeon control over inflating and deflating the balloon.
Balloon Styles: Body Styles:Available in textured and smooth Available in polyurethane or wire-reinforcedballoon configurations silicone configurations
RETRACTAGUARDTECHNOLOGYThis proprietary technology is designed to help thecannula retain its shape after deployment in thepatient and to help prevent balloon slippage,particularly during posterior graftingprocedures.
† Female luer instead of stopcock
Retractaguardtechnology
HA
ND
LECO
NFI
GU
RATI
ON
S
SPECIFICATIONSCATHETER SIZE 12 FR 14 FRBALLOON STYLE Textured Textured SmoothBODY STYLE Polyurethane Polyurethane Wire-reinforced silicone Wire-reinforced siliconeRETENTION Retractaguard Retractaguard Conventional ConventionalTECHNOLOGY technology technologyPRE-SHAPED RC2012MIBB RC2014MIBB SRT014MIBB RC014MIBBSTYLET ANDHANDLEGUIDEWIRE RC2012MIB RC2014MIB SRT014MIB RC014MIBSTYLET PLD014MIBH†
HOURGLASS - - - ISP3039HANDLE ANDGUIDEWIRESTYLET
Smoothballoon
AR05171_EDW_Spec_Cardio_Retro_1.qxd:Layout 1 6/21/10 3:48 PM Page 4
Edwards Lifesciences LLC | www.edwards.com
Irvine, USA | Nyon, Switzerland | Tokyo, Japan | Singapore, Singapore | Sao Paulo, Brazil |
References:1. Buckberg Gd. Antegrade/Retrograde Blood Cardioplegia to Ensure Cardioplegic Distribution: Operative Techniques
and Objectives. J Card Surg 1989;4(3):216-238.2. Loope Fd, Higgens Tl, Panda R, et al. Myocardial Protection During Cardiac Operations. J Thorac Cardiovasc Surg
1992;104:608-618.3. Buckberg Gd. Myocardial Protection: An Overview. Semin In Thorac Cardiovasc Surg 1993;5(2):98-106.4. Borger MA, Rao V, Weisel RD, et al. Reoperative coronary bypass surgery: Effect of patent grafts and retrograde
cardioplegia. J Thorac Cardiovasc Surg 2001;121:83-90.5. RangarajAT, et al. Real-time visualization and quantification of retrograde cardioplegia delivery using near infrared
fluorescent imaging. J Card Surg 2008;23(6):701-8.
CAUTION: Federal (USA) law restricts this device to sale by or on the order of a physician.See instructions for use for full prescribing information.
Edwards, Edwards Protection Cannulae and Retractaguard are trademarks of Edwards Lifesciences Corporation. EdwardsLifesciences and the stylized E logo are trademarks of Edwards Lifesciences Corporation and are registered in theUnited States Patent and Trademark Office. © 2010 Edwards Lifesciences LLC. All rights reserved. AR05171
0
10
20
30
40
50
60
0 50 100 150 200 250 300
Pres
sure
Dro
p(m
mH
g)
Flow Rate (ml/min), H2O at Room Temperature
Retrograde Cardioplegia CatheterPressure Drop vs. Flow
14 Fr. Self-Inflating,Retractaguard technology
9 Fr. Self-Inflating,Conventional
12 Fr. Self-Inflating,Retractaguard technology
14 Fr. Self-Inflating,Conventional
14 Fr. Manually Inflating,Conventional
12 Fr. Manually Inflating,Retractaguard technology
14 Fr. Manually Inflating,Retractaguard technology