Page 1: Refrigerant Recovery...Lovac is equipped with full 3/4fl internal piping and valving and a 2.0hp open drive compressor to quickly recover chiller refrigerant. The open drive compressor

Faster Speed Recovers R11 at 100-lb/min liquid and 0.66-lb/min vapor.On transfer tests between two cylinders, LOVAC recovered500-lbs of R11 to 29� Hg vacuum in just 13-minutes.

Noncondensibles? Not an Issue!In the above transfer test, we introduced 32-ft3 of air to thecylinder being recovered. With the ambient temperatureover 100°F, recovery only took an extra 1.5 minutes in spiteof the heavy contamination. LOVAC�s compressor worksagainst very high head pressures and the on-board directexpansion unit rapidly condenses and subcools recoveredrefrigerant to minimize the effects of noncondensibles.

High DurabilityRugged 2.0-hp open drive compressor stands up to difficultrecovery conditions better than vacuum pumps.

Refrigerant CompatibilityServices all low pressure refrigerants. Switching betweenR11, R123, & R113 simply involves evacuating the recov-ery unit, changing fluid and replacing two external filters.

Easy Operations � Evacuating lines and switching from liquid to vapor

recovery modes simply involves turning three valvesand rerouting one hose. Automatically shuts off uponachieving 29-in Hg vacuum in the cooling system.

LOVAC Outpaces Other RecoverySystems, Especially WhenRefrigerant is contaminated withMoisture, Oil, or Noncondensibles.

Refrigerant Recovery

LovacTM

Low Pressure Recovery System

Other Refrigerant Handling Products from Carrier:

TotalVacHandiVacMityVacEvac CommercialAllvacEnviroPurgeMiniPurge

Electromechanical Model

Page 2: Refrigerant Recovery...Lovac is equipped with full 3/4fl internal piping and valving and a 2.0hp open drive compressor to quickly recover chiller refrigerant. The open drive compressor

XXX X XXX XLovac.......................... CRLAir Cooled ............................. AWater Cooled......................... W103-127V,50/60Hz,1Ph,2Hp............ 115220-240V,50/60Hz,1Ph,2Hp............. 240Electromechanical Controls, Open Drive........... E

Included with Purchase:� One power cord� Two each 3/4�-5/8� and 5/8�-1/2� reducing fittings� Electromechanical model includes:

- Two 48-in3 filter drier cores: FD-048-CR- One 3/4 in. x 20 ft. hose: 075-020-HP-FB- Two 3/4 in. x 10 ft. hoses: 075-010-HP-FB

Optional Accessories:� Spare filter driers:

FD-048-CR 48-in3 filter drier cores� Compressor fluid, 1 gal: OIL-POE-1G� 440 lb. & 880 lb. recovery tanks 3/4 in. ports � Tank float safety cables & adapters

SPECIFICATIONS

Lovac is equipped with full 3/4� internal pipingand valving and a 2.0hp open drive compressorto quickly recover chiller refrigerant. The opendrive compressor is highly tolerant of noncon-densibles and makes the unit lighter and moretransportable.

Electromechanical or Microprocessor controlsare available. The unit may also be air or watercooled. Lovac�s high capacity air cooled con-denser has been tested under 140°F ambientconditions with excellent results and providesmore convenient operations.

PART NUMBERS

Gain the Capacity to Quickly Recover Charges From Medium & LargeTonnage Low Pressure Chillers.

Recovery Rates (R11)� Open Drive Model Liquid = 100-lb/min Vapor = 0.66-lb/minFinal Vacuum 29-in HgPower: Recovery Unit 103-127VAC, 1φ, 50/60Hz, 2.0-hp, 10AWeight: 135-lbs (62-kg) Shipping: 245-lbs (112-kg)Connections 3/4-in male flare fittings with ball valvesWarranty 1-year PartsDimensions (LxWxH)

26in (59cm) x 25in (56cm) x 45in (101cm)

Vapormizer lowpressure recoverytanks: 440 & 830 lbcapacities (opt.)

10 ft.x3/4 in.hoses (incl.)

20 ft.x3/4 in.hoses (incl.)

Low pressurechiller

Replacement Components Division � © Carrier Corporation 11/99 Rev. C 03/02Manufacturer reserves the right to make changes to products and specifications. www.totaline.com Literature Number 570-571