RECORD NOTES OF THE MEETING ON SCHEDULING AND
Annexure-1(1/2)
Annexure-1(2/2)
SPPD
Description Status Yes /
No
Remarks SPD1 SPD2 SPPD
1
Register with SRLDC as User ( Entity )
Yes / No Appendix - IV ( Fees & Charges
of RLDC , CERC Regulations ,
2015
2as per CERC , RE Framework Sch. & forcasting : Annexure - I
Yes / No Annexure - I ( Technical Data )
3
SLD : Visible ( PDF )
Yes / No Complete Project w.r .t
Metering , Protection , Scheme
, etc.
4Notarized copy of PPAs w. r .t connectivity with SPPD
Yes / No
5
Forecast and Schedule Data to be submitted by Wind/Solar
plants/ Lead generator, Principal generator , ( Annexure - II )
Yes / No Annexure - II ( forecast Data )
6 Real Time Avilabiltiy ( Annexure -III ) Yes / No Annexure - III
7generation data ( Annexure - IV )
Yes / No Annexure - IV
8ABT compliant meters at inter - connection points ( ABT
compliant meters shall have provision of automatic meter
reading technology for data transfer to SRLDC )
Yes / No
8.1
SEM Sample Data : NPC (Text file ) , for L&T : DAT , Secure :
MRI ….
Yes / No
8.2 Make of meter / Meter Sl. No. / CT & VT Ratio Yes / No
8.3 Time drift statement Yes / No
9 Notarized copy of PPA RATES on Affidavit TO SRPC for DSM
Preparation
Yes / No Affidavit
10 shall be responsible for sending the SCADA data to the RLDC
and to the Renewable Energy management Center , as and
when required.
Yes / No
11Undertaking by Licensee / Generating Company
Yes / No
11.1Shall be responsible for ensuring metering ( ABT compliant
meter ) , data collection and weekly transmission of data ( in
SRLDC data format ) to SRLDC as per IEGC and extant CERC
Regulations
Yes / No
11.2
Shall under take commercial settlement of all deviation
settlement charges to the Regional Pool Account on Weekly
basis , as per applicable CERC Regulations
Yes / No
11.3
Shall be responsible for commercial settlement on scheduled
generation with it beneficiaries as per the monthly Regional
Energy Account (REA ) issued by SRPC .
Yes / No
SPD /SPPD : CHECK LIST FOR SCHEDULING
S.No. SPD Verification Check List
ANNEXURE 2
SPPD
Description Status Yes /
No
Remarks SPD1 SPD2 SPPD
SPD /SPPD : CHECK LIST FOR SCHEDULING
S.No. SPD Verification Check List
ANNEXURE 2
11.4shall abide by the IEGC and CEA Regulations.
Yes / No
11.5shall follow the new element / generator procedure of SRLDC
while connecting to the grid .
Yes / No
11.6shall undertake to indemnify , defend and save SRLDC
harmless from any and all damages , losses including
commercial lossess due to forecasting error , claims and
actions including commercial losses due to forecasting error ,
claims and actions including those relating to injury to or
death of any person or damage to property , demands , suits
, recoveries , costs and expenses , court costs , attorney fees ,
and all other obligations by or to third parties , arising out of
or resulting from thetransactions undertaken by the
generators .
Yes / No
11.7Shall inform SRLDC regarding the new additions / deletion of
Power system elements within the solar park , as and when
there is a change .
No
11.8Shall be responsible for getting approval of SRPC of the
metering scheme and accounting methodology of solar park
and for each SPD.
No
11.9Shall provide the information sought by SRLDC & SRPC
regarding the solar park activities from time by coordinating
with the SPDs.
No
12
Shall submit to SRLDC the grant of connectivity agreement
with CTU / STU and the agreements entered with SPDs.
Yes / No
13Exemption of transmission charges and losses for the use of
ISTS network ( as per Central Electricity Regulatory
Commission (Sharing of Inter State Transmission Charges and
Losses) (Fifth Amendment) Regulations, 2017. dated :
14.12.2017 )
Yes / No
14
LTA Operationalization
Yes / No