4 MHz Radiofrequenz-Gerät mit bipolarem Modus für die Wirbelsäulenchirurgie
Focus on Effect
Spec
ifica
tions
sub
ject
to c
hang
e w
ithou
t not
ice.
B 79
9.VI
II.14
.EN
.1 Radioblator RF 4 MHzMultidisciplinary radiofrequency surgical device
Radioblator RF 4 MHzConserving frequency for sensitive structures
Focus on Effect
The precisely focused effect of the 4 MHz technology to conserve peripheral
tissue makes the Radioblator RF 4 MHz ideal for applications close to sensitive
structures, as necessary in e.g. neurosurgery and spine surgery. The complete
radiofrequency surgery solution offers efficient vaporization, gentle coagulation
and a range of cutting modes in monopolar or bipolar operation.
02
Pioneering technologies
The patented automatic control of
the RF current, corresponding to
the impedance of the tissue, allows
surgeons to achieve a uniform quality
for the desired tissue effects. This
applies to all monopolar and bipolar
modes.
An intelligent, pulsed power output
permits a high energy input into the
tissue during coagulation without
undesired carbonization effects in
the tissue and therefore guarantees
adequate hemostasis.
Specialist full-endoscopic spine surgery
The significantly reduced lateral
spread of heat makes working close
to sensitive structures, e.g. nerves,
much more exact and reduces risk.
The use of different bipolar currents
enables the surgeon to achieve the
desired effects of gentle coagulation
to aggressive vaporization or ablation
to suit individual circumstances and
situations.
4 MHz – on one wavelength with precision
As the frequency of the electric
current rises, the electrical resistance
of the biological tissue falls. At the
4 MHz operating frequency of the
Radioblator RF 4 MHz Generator, the
cell membranes are capacitively
bridged such that the thermal effect
of the electrical fields acts directly in
the cells.
Experts in many specialist areas
The Radioblator RF 4 MHz Generator
can be used in the operating room
for a large number of electrosurgical
functions by implementing a wide
range of operating modes. The
Radioblator is very easy to operate
and the opportunities offered by
programming application-specific
parameters allow it to be used in an
approach for the following areas:
Orthopedics
Neurosurgery
Ear, nose and throat medicine
Oral and maxillofacial surgery
Plastic /Cosmetic surgery
Dermatology
Lateral thinking round corners – the TipControl Concept
TipControl is a series of instruments
articulated at the distal end. They are
used especially in full-endoscopic
operations on the spine in order to
achieve adequate scope of move-
ment through minimally invasive
ports to the operating site. The
TipControl electrodes also enable
surgeons to use this intelligent
concept for all RF applications.
03
www.richard-wolf.com
Spec
ifica
tions
sub
ject
to c
hang
e w
ithou
t not
ice.
B 79
9.VI
II.14
.EN
.1
Radioblator RF 4 MHz System
Radioblator RF System set comprising:Radioblator RF System (2330001), power/mains cable (244003), double-pedal foot switch (2330901) and cable for disposable neutral electrodes (2330045) ...................................... 23300011
TipControl RF accessories, bipolar
TipControl RF Instrument Set short, WL 290 mmcomprising:Handle bipolar (899351100), sheath tube short, OD 2.5 mm (899351010) ..... 899351000
TipControl RF electrode, short, sterile, pack of 5 ........................................................................................... 499351000
TipControl RF Instrument Set long, WL 400 mmcomprising:Handle bipolar (899351100), sheath tube long, OD 2.5 mm (899352010) ...... 899352000
TipControl RF electrode, long, sterile, pack of 5 ........................................................................................... 499352000
TipControl connection cable, bipolar, connection cable for EU flat connector, 2-PIN International power plug, cable length 3 m ............................................. 899351210
Ablation electrodes, bipolar – for application from 5.6 mm working channel
Bipolar hollow-sphere electrode,WL 330 mm, for single use
distal head part OD 2.9 mm ........................................................................... 899364300
distal head part OD 3.4 mm ........................................................................... 899364400
also:Electrode handle, bipolar, for accommodating bipolar hollow-sphere electrodes, fixed cable with 2-PIN International power plug, cable length 3 m ...................... 899364200
RF accessories, monopolar
Monopolar handlewith cable 4 m, for electrodes with shaft 2.4 mm, for US generators and Erbe "International" ....................................................... 89910.0001
Disposable neutral electrodes,Pack of 50, packed single, non-sterile ................................................................... 433015
Cablefor disposable neutral electrodes, cable length 3 m ............................................... 2330045
Radioblator RF 4 MHzand accessories