Transcript
Page 1: QUICK START INSTALLATION GUIDE - MechTronic · Web viewQUICK START INSTALLATION GUIDE QUICK START INSTALLATION GUIDE DISPENSING VOLUME WITHOUT PRESET The following steps the operator

QUICK START INSTALLATION GUIDE

DISPENSING VOLUME WITHOUT PRESETThe following steps the operator may take to dispense product without a preset.

1. In Volume Mode, press button to initiate delivery2. Deliver Product to desired amount.3. Press .

DISPENSING VOLUME WITH PRESET BEFORE DISPENSINGThe following steps the operator may take to dispense product with a preset before the delivery.

1. Press, press press This will display a flashing line.

Now using and you can enter the required preset. Now press followed by

2. Deliver Product until Preset level is reached and flow is shut down. Note delivery will slow at end of preset automatically.3. Press

DISPENSING VOLUME WITH PRESET DURING DISPENSINGThe following steps the operator may take to dispense product with a preset during the delivery.

1. In Volume Mode, press button to initiate delivery

2. Press, press press This will display a flashing line.

3. Now using and you can enter the required preset. Now press followed by 4. Deliver Product until Preset level is reached and flow is shut down. Note delivery will slow at

end of preset automatically.5. Press

Page 2: QUICK START INSTALLATION GUIDE - MechTronic · Web viewQUICK START INSTALLATION GUIDE QUICK START INSTALLATION GUIDE DISPENSING VOLUME WITHOUT PRESET The following steps the operator

QUICK START INSTALLATION GUIDE

Initiating the Setup Mode

1. Turn On power to the Display Head and wait until the boot-up sequence completes.2. Depress the button until the indicator at the bottom of the display points to Setup.3. On initial power-up of the Display Head, the first Setup Mode category,With the screen showing 0 press the button this will display DEFAULTS press Now scroll down to ENTER SECURITY CODE and follow the steps below. The default security code is 862811

.

Setup Mode CategoriesThe non-metrologically controlled Setup Mode categories for the EMR3 System are:• Enter Security Code - enables user log in/out procedure. (Note: This prompt will not display on initial power-upof the Display Head. If you have enabled Security Code in the C&C Mode, this prompt will be the first categoryto display on entering Setup Mode).• Pricing setup - sets up to 15 different price codes with tax/discount code assignments.• Tax/Discount setup - sets up to 15 different tax/discount (T/D/S) codes with up to 6 different T/D modifiersper code.• Defaults setup - lets you set the mode you want the Display Head to enter when beginning pre-dispense anddispense operations; and lets you enable/disable volume and currency mode presets.• Relay Control setup - sets the shutoff points for flow control relays 1 and 2 for preset deliveries.• Security setup - sets the user Passcodes and user access to certain Setup Mode categories. (This setup onlydisplays after enabling Security Code in the C&C Mode).• Printer Option setup - sets optional printer type and distance from top of ticket to first printed line.• View Records setup - lets you select to either view or print any of the last 20 transaction records.• Restore Records - Allows the user to restore (download from IB to Display Head) up to the last 20transactions.• Shift setup - sets up shift start/end times, start/end odometer readings, and tank loadings. Also within Shiftsetup, you can print out shift reports.• Date Format setup - sets the format of year, month, and date for use in display and printouts.• Time/Date setup - lets you enter the current time and date.• System Address setup - sets the addressing and configuration of the individual EMR3 components and theirinputs from, and outputs to, the system.• Time Delays setup - sets the delay (in seconds) after which the display will go blank if there is no activity.• Version Number - lets you view system device version numbers.• C&C - lets you step through and view, but not change, the C&C Mode setups (see page 31).Instructions for setting up the Setup Mode categories are shown in the figures that follow. In some cases multiplefigures are used to explain sub-procedures within a Setup Mode category.

Page 3: QUICK START INSTALLATION GUIDE - MechTronic · Web viewQUICK START INSTALLATION GUIDE QUICK START INSTALLATION GUIDE DISPENSING VOLUME WITHOUT PRESET The following steps the operator

QUICK START INSTALLATION GUIDE

Note, once you have entered a Setup Mode category (pressing NEXT), do not press the ‘+’, ‘-’ buttons in thatsetup if you do not intend to change a value, because when you press ENTER, the change, even if unintended, willbe accepted. If you want to view setup settings without making changes, press NEXT to move ‘into’ a category’ssetup and ENTER to ‘back out’ of the setup.

Delivery Error CodesThe current delivery will automatically FINISH when a delivery error occurs.E04 - ENCODER PULSE ERRORThis error is an indication that an illegal quadrature state has occurred. It is possible this error is caused by arandom event and another delivery may be started. Should this error repeat itself, the source of the error must befixed. Before replacing the encoder check the IB input voltage for dropout or power surges. Some solenoid valvesdo not have diode suppression and may cause the supply voltage to drop out. Add diodes (Veeder-Root P/N846000-022) across the solenoid coils as noted in the installation manual. An over speed condition (>1250 rpm)will also cause an E04 error.E06 - TEMP PROBE TOO HOTThe measured temperature is greater than +160°F (71.1°C). This error can also be caused by poor connections ina junction box when wire is added to the original temperature probe and a poor connection is made. Soldering is recommenced - not just wire nuts.

E07 - TEMP PROBE TOO COLDThe measured temperature is less than -55°F (-48.3°C).When the fluid temperature is outside of the EMR³ 's measurable range, a delivery can not continue or start. Gointo the C&C Menu, under TEMPERATURE, check what the EMR³ reads for the fluid's temperature. If the EMR³temperature is wrong remove or replace the thermoprobe and recalibrate.E08 - TEMPERATURE PROBE FAILUREThe thermo probe wires are either shorted together or are not connected to the TP terminals on the Display Head.Check the thermo probe connections on the back of the Display Head. If the thermo probe wiring is corroded, remove both leads and trim them. Cut back the cable insulation and strip each wire by 1/4 of an inch (5 mm).Insert both wires into the terminal block and tighten. To test a thermo probe, connect each lead to an ohmmeter and measure the resistance. At 77°F (25°C), the meter should read about 10 K ohms. If not, replace the probe(Veeder-Root P/N 846000-002).

Startup Error CodesThe following messages apply to self-testing during the power up sequence. Should any of these messagesappear, try cycling the power before replacing the Display Head Module.E05 - NVRAM FAILTest of nonvolatile random access memory. The NVRAM is a piece of semiconductor memory hardware used as a data storage device. To either write or read data into NVRAM the CPU (central processing unit) places addressEMR3 Troubleshooting Guide System Error Codes63and data information on the bus lines and then toggles the appropriate control signals. The EMR3 uses NVRAM to store setup values, the current amount of product dispensed and other historical data. Each value stored inNVRAM has a checksum that validates the integrity for each piece of data. This error occurs when data being read does not agree with its respective checksum.

E15 - RAM FAIL

Page 4: QUICK START INSTALLATION GUIDE - MechTronic · Web viewQUICK START INSTALLATION GUIDE QUICK START INSTALLATION GUIDE DISPENSING VOLUME WITHOUT PRESET The following steps the operator

QUICK START INSTALLATION GUIDE

Test of static random access memory. The RAM is a piece of semiconductor memory hardware used as a temporary data storage device. To either write or read data into RAM the CPU (central processing unit) places address and data on the bus lines and then toggles the appropriate control signals. The EMR3 uses RAM to store general-purpose data that is erased once power is removed. Every RAM location is tested by the CPU and theE15 error occurs when data being read does not agree with the written information.

E16 - FLASH FAILTest of program memory. The Flash is a piece of semiconductor memory hardware used to store the firmware.Firmware is computer software providing all of the instructions used by the CPU (central processing unit) tooperate the EMR3. This error occurs when the checksum for the FLASH device does not agree with its stored checksum.E17 - ADDR FAILCan not access all devices connected to the CPU's address bus. An address is a unique designation for thelocation of data or the identity of other hardware devices. The CPU uses 20 address lines to communicate withdevices connected to the address bus. Any device that fails to respond when properly addressed will cause thiserror.

E18 - DATA FAILCan not send or receive data from all of the devices connected to the CPU. In the EMR3, information isrepresented in binary format so that it can be stored, manipulated and transmitted. Data is communicated 16 bitsat a time and each of the 16 CPU data lines are tested for the proper response.

E19 - UART FAILThe hardware used to perform serial communications has failed or locked up. UART stands for universalasynchronous receiver/transmitter and as many as 4 are integrated into the CPU. In each EMR3 system the UARTsare used for serial communication between the IB and Display Head as well as for external communications. Theconfiguration registers inside each UART are written to and read from by the CPU. Any register values that do notprogram correctly will result in this error. Any status register conditions that result in a condition that can not becorrected by the CPU will result in this error.If during start-up, the Display Head stops in any self-check mode, cycle the power. Should the situation persist,replace the Display Head.

System Error CodesE50 - IB COMM FAILURESerial communication from the IB Box is not working. Check the wiring at both the Display Head and the IB, make sure A goes to A and B goes to B. At the IB box check the tri-color LED, make sure it is flashing. If the IB Comm Error continues, try swapping the Display Head 1 wiring with the Display Head 2 wiring. If the problem follows the

IB INDICATOR LIGHTS AND IB SELF CHECKSThe tri-color LED, located inside the Interconnection Box, is capable of indicating 4 different states: Green, Red,Yellow and Off. At start up, the LED flashes the initialization sequence of Off-Green-Red-Yellow-Off indicating that the IB self-test passed with no errors to display. If one or more Display Heads are communicating with the IB theLED will flash an Off-Green-Off pattern repeatedly. If one or more IB Relay is active, or a delivery is in process, theLED will flash an Off-Yellow-Off sequence until all the relays are inactive.

Page 5: QUICK START INSTALLATION GUIDE - MechTronic · Web viewQUICK START INSTALLATION GUIDE QUICK START INSTALLATION GUIDE DISPENSING VOLUME WITHOUT PRESET The following steps the operator

QUICK START INSTALLATION GUIDE

If a communication error occurs, the LED will flash Off-Red-Off indicating a problem. Try swapping the DisplayHeads as described above in order to locate the problem. The LED will not indicate a non-functional Display Head.If a self-test error occurs, the LED will flash an Off-Red-Off-Red-Off sequence indicating a problem. Try swappingthe IB with another IB in order to locate the problem.If the LED is stuck in one of the 4 states, remove input power from the input terminals for a few seconds. Restore power and check the LED for the Off-Green-Red-Yellow-Off sequence. If the LED fails to flash in the proper sequence, replace the IB Circuit Board.E66 - PRINTER BUSYThe E66 Printer Busy error means that the printer still has information to print from the previous transaction. If a transaction is complete, but no ticket was put in the printer, the display can be ‘reset’ to zero by pushing theFINISH button. When the START button is pushed, the Printer Busy Error comes up. The printer icon should be flashing to indicate there is information to be printed. The ability to ‘reset’ the register is based on a ticket sensing switch inside the printer that clears once a ticket has been removed. The data that needs to be printed is still however, in the printer’s buffer memory as indicated by the flashing icon.Another possibility is that the previous transaction printed some or most of the information on the ticket, but theticket was not long enough to print all the information (the printer icon should be flashing). Install a blank ticket intothe printer and the remaining information will finish printing. Keep in mind that if the operator thinks all of the linesprinted, there may still be blank lines in the format that have to print to complete the ticket.Cycling the printer power will clear the printer memory and the Printer Busy Error. However, the transaction recordis in the EMR3 system memory and can be recalled using view records or printing records.

Slow flow and stop set upNow press the MODE button to return to main screen.

To achieve accurate stopping on a given preset the following set up should be followed.With the bulk pipe connected set a preset delivery of 300L.Do not increase engine speed for this run.When the delivery is complete you will have a figure greater than entered at preset for example520L instead of 500L

Press MODE and navigate to RELAY CONTROL, press select RELAY 2 – SET ADVANCE STOPFollowing the instructions below, increase the advance stop to the overrun figure from above. In our example 20.00.

Page 6: QUICK START INSTALLATION GUIDE - MechTronic · Web viewQUICK START INSTALLATION GUIDE QUICK START INSTALLATION GUIDE DISPENSING VOLUME WITHOUT PRESET The following steps the operator

QUICK START INSTALLATION GUIDE

Press MODE to return to main screen.Repeat the delivery as before you should now achieve 500L. This figure can be trimmed up and down in part litres if required.Now select the RELAY 1- SET SLOW FLOW from the menu and provisionally set to 175.Set the vehicle to deliver 500L preset and start. Increase the engine speed up to its maximum (as programmed by manufacturer) and watch the delivery. Ensure engine is back to tickover before the stop signal is activated.This figure can be trimmed as before to achieve optimum slow down period.Now set the vehicle to complete a preset 200L hose delivery. open the throttle valve in the deadman exhaust to its maximum. The delivery will under run. Using the throttle valve in the deadman exhaust trim this under run to achieve 200L. In is slower out is faster.

Page 7: QUICK START INSTALLATION GUIDE - MechTronic · Web viewQUICK START INSTALLATION GUIDE QUICK START INSTALLATION GUIDE DISPENSING VOLUME WITHOUT PRESET The following steps the operator

QUICK START INSTALLATION GUIDE

PRE DISPENSE should be set to VOLUME MODEDISPENSE should be set to VOLUME MODEPRESET VIEW should be set to PRESET.

Page 8: QUICK START INSTALLATION GUIDE - MechTronic · Web viewQUICK START INSTALLATION GUIDE QUICK START INSTALLATION GUIDE DISPENSING VOLUME WITHOUT PRESET The following steps the operator

QUICK START INSTALLATION GUIDE


Recommended