1/90
5 55 5
Limit switches 3 OsiSense XC Standard, format EN 50041Plastic, double insulated, type XCK SConforming to CENELEC EN 50041
b XCK S with 1 cable entry
v With head for linear movement (plunger)
Page 1/92
v With head for rotary movement (lever)
Page 1/92
Environment characteristicsConformity to standards Products IEC 60947-5-1, EN 60947-5-1, UL 508, CSA C22-2 n° 14
Machine assemblies IEC 60204-1, EN 60204-1
Product certifications UL, CSA, CCCProtective treatment Version Standard: “TC” and “TH”Ambient air temperature For operation - 25…+ 70°C
For storage - 40…+ 70°C
Vibration resistance Conforming to IEC 60068-2-6 25 gn (10…500 Hz) Shock resistance Conforming to IEC 60068-2-27 50 gn (11 ms) Electric shock protection Class II conforming to IEC 61140 and NF C 20-030Degree of protection IP 65 conforming to IEC 60529; IK 03 conforming to EN 50102 Repeat accuracy 0.05 mm on the tripping points, with 1 million operating cycles for head with end plunger Cable entry Depending on model Tapped entry for n° 13 cable gland or tapped ISO M20 x 1.5Materials Bodies and heads: plastic
5616
56
5616
57
5616
58
5616
59
5616
60
5616
61
Presentation, general characteristics
1
2
3
4
5
6
7
8
9
10
5 5
1/91
5 5
Limit switches 3 OsiSense XC Standard, format EN 50041Plastic, double insulated, type XCK SConforming to CENELEC EN 50041
Contact block characteristicsRated operational characteristics
XE2p P a AC-15; A300 (Ue = 240 V, Ie = 3 A); Ithe = 10 A c DC-13; Q300 (Ue = 250 V, Ie = 0.27 A), conforming to IEC 60947-5-1 Appendix A, EN 60947-5-1
XE3p P a AC-15; B300 (Ue = 240 V, Ie = 1.5 A); Ithe = 6 A c DC-13; R300 (Ue = 250 V, Ie = 0.1 A), conforming to IEC 60947-5-1 Appendix A, EN 60947-5-1
Rated insulation voltage XE2p P Ui = 500 V degree of pollution 3 conforming to IEC 60947-1 Ui = 300 V conforming to UL 508, CSA C22-2 n° 14
XE3p P Ui = 400 V degree of pollution 3 conforming to IEC 60947-1 Ui = 300 V conforming to UL 508, CSA C22-2 n° 14
Rated impulse withstand voltage
XE2p P U imp = 6 kV conforming to IEC 60947-1, IEC 60664XE3p P U imp = 4 kV conforming to IEC 60947-1, IEC 60664
Positive operation (depending on model) NC contacts with positive opening operation conforming to IEC 60947-5-1 Appendix K, EN 60947-5-1Resistance across terminals y 25 mΩ conforming to IEC 60255-7 category 3Short-circuit protection XE2p P 10 A cartridge fuse type gG (gl)
XE3p P 6 A cartridge fuse type gG (gl)
Connection(screw clamp terminals)
XE2S P21p1 Clamping capacity, min: 1 x 0.34 mm2, max: 2 x 1.5 mm2
XE2N P21p1 Clamping capacity, min: 1 x 0.5 mm2, max: 2 x 2.5 mm2
XES P3021 Clamping capacity, min: 1 x 0.75 mm2, max: 2 x 1.5 mm2
XE3N P and XE3S P Clamping capacity, min: 1 x 0.34 mm2, max: 1 x 1 mm2 or 2 x 0.75 mm2
Minimum actuation speed XE2S P21p1, XES P3021 and XE3S P: 0.01 m/minuteXE2N P21p1 and XE3N P: 6 m/minute
Electrical durability Conforming to IEC 60947-5-1 Appendix CUtilisation categories AC-15 and DC-13Maximum operating rate: 3600 operating cycles/hourLoad factor: 0.5
bbbb
XE2S P21p1, XE2S P2141 XE2N P21p1 XES P3021AC supply 50/60 Hz a o inductive circuit
DC supply c Power broken in W for 5 million operating cycles.
Power broken in W for 5 million operating cycles.
Power broken in W for 5 million operating cycles.
Voltage V 24 48 120 Voltage V 24 48 120 Voltage V 24 48 120o W 10 7 4 o W 13 9 7 o W 10 7 4For XE2S Pp151 on a or c, NC and NO contacts simultaneously loaded to the values shown with reverse polarity.XE3S Ppppp XE3N Ppppp
AC supply 50/60 Hz a o inductive circuit
DC supply c Power broken in W for 5 million operating cycles.
Power broken in W for 5 million operating cycles.
Voltage V 24 48 120 Voltage V 24 48 120o W 3 2 1 o W 4 3 2
Mill
ions
of o
pera
ting
cycl
es
Current in A
0.1
0.5
1
5
0.5 1 5 10
110 V
48 V230/400 V
2 3 4
Ithe
24 V
0.5 1 2 3 4 5 100.1
0.2
0.5
1
5
2
43
Ithe
230 V 12/24/48 V
110 V
Mill
ions
of o
pera
ting
cycl
es
Current in A
Mill
ions
of o
pera
ting
cycl
es
Current in A0.5 1 2 5 10
0.1
0.5
1
5
2
34
230 V 48 V
Ithe
12/24 V
3 4
110 V
0.1
0.5
1
5
0.5 1 5 10
110 V
48 V
230/400 V
2 3 4
Ithe
24 VMill
ions
of o
pera
ting
cycl
es
Current in A
Mill
ions
of o
pera
ting
cycl
es
Current in A0.5 1 2 3 4 5 10
0.1
0.2
0.5
1
5
2
43
Ithe
230 V110 V
12/24/48 V
General characteristics (continued)
1
2
3
4
5
6
7
8
9
10
1/92
5 55 5
Limit switches OsiSense XC Standard, format EN 50041Plastic, double insulated, type XCK SConforming to CENELEC EN 50041Complete switches with 1 cable entry
Type of head Plunger (fixing by the body) Rotary (fixing by the body)Form B (1) Form C (1) Form A (1) Form D (1)
Type of operator Metal end plunger
Steel roller plunger
Thermoplastic roller lever (2)
Elastomer roller lever, Ø 50 mm (2)
Variable length thermoplastic roller lever (2)
Variable length elastomer roller lever (2)
Round thermoplastic rod lever, Ø 6 mm (4) (5)
References of complete switches with 1 ISO M20 x 1.5 cable entry(3)2-pole NC + NO snap action (XE2S P2151)
XCK S101H29
XCK S102H29
XCK S131H29
XCK S139H29 XCK S141H29 XCK S149H29 XCK S159H29
2-pole NC + NO break before make, slow break (XE2N P2151)
XCK S501H29
XCK S502H29
XCK S531H29
XCK S539H29 XCK S541H29 XCK S549H29 XCK S559H29
2-pole NC + NC snap action (XE2S P2141)
ZCK S9H29 + ZCK D01
ZCK S9H29 + ZCK D02
ZCK S9H29 + ZCK D31
ZCK S9H29 + ZCK D39
ZCK S9H29 + ZCK D41
ZCK S9H29 + ZCK D49
ZCK S9H29 + ZCK D59
2-pole NC + NC simultaneous, slow break (XE2N P2141)
ZCK S7H29 + ZCK D01
ZCK S7H29 + ZCK D02
ZCK S7H29 + ZCK D31
ZCK S7H29 + ZCK D39
ZCK S7H29 + ZCK D41
ZCK S7H29 + ZCK D49
ZCK S7H29 + ZCK D59
3-pole NC + NC + NO snap action (XE3S P2141)
ZCK SD39H29 + ZCK D01
ZCK SD39H29 + ZCK D02
ZCK SD39H29 + ZCK D31
ZCK SD39H29 + ZCK D39
ZCK SD39H29 + ZCK D41
ZCK SD39H29 + ZCK D49
ZCK SD39H29 + ZCK D59
3-pole NC + NC + NO break before make, slow break (XE3N P2141)
ZCK SD37H29 + ZCK D01
ZCK SD37H29 + ZCK D02
ZCK SD37H29 + ZCK D31
ZCK SD37H29 + ZCK D39
ZCK SD37H29 + ZCK D41
ZCK SD37H29 + ZCK D49
ZCK SD37H29 + ZCK D59
Weight (kg) 0.095 0.105 0.145 0.150 0.155 0.155 0.150Contact operation closed
open(A) = cam displacement(P) = positive opening point
NC contact with positive opening operation
References of complete switches with 1 Pg 13 cable entryFor an entry tapped for a Pg 13.5 cable gland, delete H29 from the end of the reference. Example: XCK S101H29 becomes XCK S101.
CharacteristicsSwitch actuation On end By 30° cam By any moving partType of actuation
Maximum actuation speed 0.5 m/s 1.5 m/s 1 m/sMechanical durability (6)(in millions of operating cycles)
25 15 20
Minimum force or torque
For tripping 15 N 12 N 0.15 N.mFor positive opening 45 N 36 N 0.3 N.m – –
Cable entry 1 entry tapped M20 x 1.5 mm for ISO cable gland, clamping capacity 7 to 13 mm(1)FormconformingtoEN50041,seepage1/177.(2) Adjustable throughout 360° in 5° steps, or in 90° steps by reversing the notched washer.(3) Switches with gold contacts or eyelet type connections: please consult our Customer
Care Centre.(4)Adjustablethroughout360°in5°steps,orin45°stepsbyreversingthelevermounting.
(5)Valuetakenwithactuationbymovingpartat100mmfromthefixing.(6)Limitedto15millionoperatingcyclesforswitcheswithcontacts
XE3pP.
1314 22
21
1.8 4.5(P)
5.5mm
13-1421-22
21-2213-14
00.9
3.1(A) 7.8(P)
mm
13-1421-22
21-2213-14
01.5
23˚ 58 (̊P)
80˚
13-1421-22
21-2213-14
011˚
23˚
80˚
13-1421-22
21-2213-14
011˚
23˚
80˚
13-1421-22
21-2213-14
011˚
23˚
80˚
13-1421-22
21-2213-14
011˚
23˚
80˚
13-1421-22
21-2213-14
011˚
1314 22
21
1.8 3.2(P)
5.5mm
13-1421-22
0 3
3.1(A) 5.6(P)
mm13-1421-22
0 5.2
23˚ 42 (̊P)
80˚13-1421-22
0 33˚
23˚
80˚13-1421-22
0 33˚
23˚
80˚13-1421-22
0 33˚
23˚
80˚13-1421-22
0 33˚
23˚
80˚13-1421-22
0 33˚
1211
2221
1.8 4.5(P)
5.5mm
21-2211-12
11-1221-22
00.9
21-2211-12
11-1221-22
3.1(A) 7.8(P)
mm01.5
21-2211-12
11-1221-22
23˚ 58 (̊P)
80˚011˚
21-2211-12
11-1221-22
23˚
80˚011˚
21-2211-12
11-1221-22
23˚
80˚011˚
21-2211-12
11-1221-22
23˚
80˚011˚
21-2211-12
11-1221-22
23˚
80˚011˚
1211
2221
1.8
3.2(P)
5.5mm
021-2211-12
3.1(A)
5.6(P)
021-2211-12
23˚
42 (̊P)
80˚21-2211-12
0 23˚ 80˚21-2211-12
0 23˚ 80˚21-2211-12
0 23˚ 80˚21-2211-12
0 23˚ 80˚21-2211-12
0
3231
2221 13
14
13-1421-2231-32
5.5mm
13-140
0.9
1.8 4.5(P)
31-3221-22
13-1421-2231-3213-14
31-3221-22
mm01.5
3.1(A) 7.8(P)
13-1421-2231-3213-14
31-3221-22
80˚011˚
23˚ 58 (̊P)
13-1421-2231-3213-14
31-3221-22
80˚011˚
23˚
13-1421-2231-3213-14
31-3221-22
80˚011˚
23˚
13-1421-2231-3213-14
31-3221-22
80˚011˚
23˚
13-1421-2231-3213-14
31-3221-22
80˚011˚
23˚
3231
2221
1413
5.5mm
13-1431-32
0 3
1.8 3.2(P)21-22
mm13-1431-32
0 5.2
3.1(A) 5.6(P)21-22
80˚13-1431-32
0 33˚
23˚ 42 (̊P)21-22
80˚13-1431-32
0 33˚
23˚21-22
80˚13-1431-32
0 33˚
23˚21-22
80˚13-1431-32
0 33˚
23˚21-22
80˚13-1431-32
0 33˚
23˚21-22
References, characteristics
1
2
3
4
5
6
7
8
9
10
5 5
1/93
5 5
Limit switchesOsiSense XC Standard, format EN 50041Plastic, double insulated, type XCK SConforming to CENELEC EN 50041Complete switches with 1 cable entry
XCK Sp01H29ZCK Sp + ZCK D01
XCK Sp02H29ZCK Sp + ZCK D02
XCK Sp31H29ZCK Sp + ZCK D31
XCK Sp39H29ZCK Sp + ZCK D39
XCK Sp41H29ZCK Sp + ZCK D41
XCK Sp49H29ZCK Sp + ZCK D49
XCK Sp59H29ZCK Sp + ZCK D59
(1)1tappedentryforISOM20x1.5orPg13.5cablegland.(2)Ø6rod,length200mm.(3) 190 max.(4)212max.Ø:2elongatedholesØ5.3x7.3.
3629.5
103
(1)
16
4030= =
6036
.5
.
116
164
3629.5
(1)
6049
.5
4030= =
.
6029.5
129
556 39
(1)
4030= =
6063
41
.
6076
.554.5
4030= =
6529.5
142.
5
(1)
5710
.
5729.5
117.
..172
536 45
(1)
6051
.5...
106
29.5
...84
4030= =
.
132.
5...1
87.5
58
10
5729.5
(1)
40
30= =
6067
...12
1.5
45...
99.5
.
98...
280
48.5
(2)
5729.5
(1)
60(4
)(3)
24
40
30= =
.
Dimensions
1
2
3
4
5
6
7
8
9
10
1/94
5 55 5
Limit switches 0 OsiSense XC Standard, format EN 50041Plastic, double insulated, type XCK SConforming to CENELEC EN 50041Variable composition
(1)Forfurtherdetailsseepage1/96.ForacableentrytappedISOM20x1.5,addH29 to the reference. Example:ZCKS1becomesZCK S1H29.
(2) Adjustable throughout 360° in 5° steps, or in 90° steps by reversing the notched washer.(3)Adjustablethroughout360°in5°steps,orin45°stepsbyreversingthelevermounting.
ZCK D02 ZCK D029ZCK D01 ZCK D019
ZCK D08 ZCK D06
ZCK S1, S5, S6, S7, S9ZCK S2, S8
ZCK D81 ZCK D91
ZCK D33 ZCK D34ZCK D31
ZCK D39 ZCK D49 ZCK D41
ZCK D54 ZCK D55 ZCK D59
ZCK SD31, SD35, SD37, SD39
Square rod lever, steel, U 3 mm L = 125 mm (2)
Round rod lever, thermoplastic, Ø 6 mm L = 200 mm (3)
Round rod lever, glass fibre, Ø 3 mm L = 125 mm (2)
Elastomer roller lever, Ø 50 mm (2)
Variable length thermoplastic roller lever, (2)
Variable length elastomer roller lever, Ø 50 mm (2)
Thermoplastic roller lever (2)
Spring rod “Cat’s whisker” Spring-rod lever with thermoplastic end (2)
Spring-rod lever, metal (2)
Metal end plunger Steel roller plungerEnd metal plunger with protective boot
Steel roller plunger with protective boot
Body with 2-pole contact, cable entry for Pg 13.5 1 step (1)
Body with 3-pole contact, cable entry for Pg 13.5 1 step (1)
Steel roller lever (2)
Steel ball bearing mounted roller lever (2)
Presentation
1
2
3
4
5
6
7
8
9
10
5 5
1/95
5 5
Limit switches 0 OsiSense XC Standard, format EN 50041Plastic, double insulated, type XCK SConforming to CENELEC EN 50041Variable composition
(1)Forfurtherdetailsseepage1/96.ForacableentrytappedISOM20x1.5,addH29 to the reference. Example:ZCKS1becomesZCK S1H29.
: NC contact with positive opening operation or head assuring positive opening operation.(2) Adjustable throughout 360° in 5° steps, or in 90° steps by reversing the notched washer.(3)Adjustablethroughout360°in5°steps,orin45°stepsbyreversingthelevermounting.
ZCK D05
ZCK Y33 ZCK Y34ZCK Y31
ZCK Y41 ZCK Y43
ZCK Y81 ZCK Y91
ZCK Y59
ZCK S404
ZCK Y49 ZCK Y39
ZCK Y55ZCK Y54
Square rod lever, steel, U 3 mm L = 125 mm (3)
Round rod lever, Ø 6 mm L = 200 mm (3)
Round rod lever, glass fibre, Ø 3 mm L = 125 mm (3)
Spring-rod lever with thermoplastic end (2)
Spring-rod lever, metal (2)
Variable length thermoplastic roller lever, (2)
Variable length steel roller lever (2)
Variable lengthelastomer roller lever, Ø 50 mm (2)
Elastomer roller lever, Ø 50 mm (2)
Thermoplastic roller lever (2)
Steel roller lever (2)
Steel ball bearing mounted roller lever (2)
For actuation from left AND right or from left OR right
Body with double-pole 2 CO, staggered, snap action contact cable entry for Pg 13.5 2 step, 1 from left AND 1 from right (1)
Presentation (continued)
1
2
3
4
5
6
7
8
9
10
1/96
5 55 5
Limit switches 0 OsiSense XC Standard, format EN 50041Plastic, double insulated, type XCK S Conforming to CENELEC EN 50041 Adaptable sub-assemblies
References
Bodies with 2-pole contactType With contact
blockScheme Positive
operation (1)Cable entry Reference Weight
kg1 step NC + NO
snap action (XE2S P2151)
Pg 13.5 ZCK S1 0.080
ISO M20 x 1.5 ZCK S1H29 0.080
2 CO simultaneous, snap action (XES P3021)
– Pg 13.5 ZCK S2 0.080
ISO M20 x 1.5 ZCK S2H29 0.080
NC + NO break before make, slow break (XE2N P2151)
Pg 13.5 ZCK S5 0.080
ISO M20 x 1.5 ZCK S5H29 0.080
NO + NC make before break, slow break (XE2N P2161)
Pg 13.5 ZCK S6 0.080
ISO M20 x 1.5 ZCK S6H29 0.080
NC + NC simultaneous, slow break (XE2N P2141)
Pg 13.5 ZCK S7 0.080
ISO M20 x 1.5 ZCK S7H29 0.080
NO + NO simultaneous, slow break (XE2N P2131)
– Pg 13.5 ZCK S8 0.080
ISO M20 x 1.5 ZCK S8H29 0.080
NC + NC snap action (XE2S P2141)
Pg 13.5 ZCK S9 0.080
ISO M20 x 1.5 ZCK S9H29 0.080
Bodies with double-pole contact and spring return rotary headWithout operating leverType With contact
blockScheme Positive
operation (1)Cable entry Reference Weight
kg2 step 1 from left and 1 from right
2 CO staggered snap action
– Pg 13.5 ZCK S404 0.150
ISO M20 x 1.5 ZCK S404H29 0.150
Bodies with 3-pole contact and 1 cable entryType With contact
blockScheme Positive
operation (1)Cable entry Reference Weight
kg– NC + NO + NO
snap action (XE3S P2151)
Pg 13.5 ZCK SD31 0.080
ISO M20 x 1.5 ZCK SD31H29 0.080
NC + NC + NO snap action (XE3S P2141)
Pg 13.5 ZCK SD39 0.080
ISO M20 x 1.5 ZCK SD39H29 0.080
NC + NC + NO break before make, slow break (XE3N P2141)
Pg 13.5 ZCK SD37 0.080
ISO M20 x 1.5 ZCK SD37H29 0.080
NC + NO + NO break before make, slow break (XE3N P2151)
Pg 13.5 ZCK SD35 0.080
ISO M20 x 1.5 ZCK SD35H29 0.080
(1) : NC contact with positive opening operation or head assuring positive opening operation.
222113
14
22
21
23
24
12
11
13
14
222113
1422
21
1413
1211
2221
1314 24
23
1211
2221
222123
24121113
1432
31 1314
3334
3231
2221 13
14
3231
2221 13
14
2221 13
14
3334
ZCKSp
ZCKS404
1
2
3
4
5
6
7
8
9
10
5 5
1/97
5 5
Limit switches 0 OsiSense XC Standard, format EN 50041Plastic, double insulated, type XCK S Conforming to CENELEC EN 50041 Adaptable sub-assemblies
References (continued)
Contact blocksType of contact Scheme For body Positive
operation (1)Reference Weight
kg2-pole contact
NC + NO snap action
ZCK S1 XE2S P2151 0.020
NC + NO break before make, slow break
ZCK S5 XE2N P2151 0.020
2 CO simultaneous snap action
ZCK S2 – XES P3021 0.045
NO + NC make before break, slow break
ZCK S6 XE2N P2161 0.020
NC + NC simultaneous, slow break
ZCK S7 XE2N P2141 0.020
NO + NO simultaneous, slow break
ZCK S8 – XE2N P2131 0.020
NC + NC snap action
ZCK S9 XE2S P2141 0.020
3-pole contactNC + NO + NO snap action
ZCK SD31 XE3S P2151 0.035
NC + NC + NO snap action
ZCK SD39 XE3S P2141 0.035
NC + NC + NO break before make, slow break
ZCK SD37 XE3N P2141 0.035
NC + NO + NO break before make, slow break
ZCK SD35 XE3N P2151 0.035
(1):NCcontactwithpositiveopeningoperationorsub-assemblyassuringpositiveopeningoperation.
Other versions Gold flashed contacts.Please consult our Customer Care Centre.
222113
14
222113
14
22
21
23
24
12
11
13
14
2221
1413
1211
2221
1314 24
23
1211
2221
3231 13
14
3334
3231
2221 13
14
3231
2221 13
14
2221 13
14
3334
XE2S P21p1
XE2N P21p1
XES P3021
XE3p P21pp
1
2
3
4
5
6
7
8
9
10
1/98
5 55 5
Limit switchesOsiSense XC Standard, format EN 50041Plastic, double insulated, type XCK S Conforming to CENELEC EN 50041 Adaptable sub-assemblies
Operation
Heads ZCK D01, D109 with bodyZCK S1 ZCK S2 ZCK S5 ZCK S6 ZCK S7 ZCK S8 ZCK S9
ZCK SD39 ZCK SD37 ZCK SD31 ZCK SD35
Heads ZCK D02, D029 with bodyZCK S1 ZCK S2 ZCK S5 ZCK S6 ZCK S7 ZCK S8 ZCK S9
ZCK SD39 ZCK SD37 ZCK SD31 ZCK SD35
Heads ZCK D31, D33, D34 with bodyZCK S1 ZCK S2 ZCK S5 ZCK S6 ZCK S7 ZCK S8 ZCK S9
ZCK SD39 ZCK SD37 ZCK SD31 ZCK SD35
Heads ZCK D39, D41, D49, D54, D55, D59, D81, D91 with bodyZCK S1 ZCK S2 ZCK S5 ZCK S6 ZCK S7 ZCK S8 ZCK S9
ZCK SD39 ZCK SD37 ZCK SD31 ZCK SD35
Heads ZCK D05 (positive operation only assured with a operating lever) with bodyZCK S1 ZCK S2 ZCK S5 ZCK S6 ZCK S7 ZCK S8 ZCK S9
ZCK SD39 ZCK SD37 ZCK SD31 ZCK SD35
Heads ZCK D06, D08 with bodyZCK S1 ZCK S2 ZCK S5 ZCK S6 ZCK S7 ZCK S8 ZCK S9
ZCK SD39 ZCK SD37 ZCK SD31 ZCK SD35
ZCK S404 (body with head)Unactuated Actuated from left Actuated from right
Contact operation G closed H open (A) = cam displacement (P) = positive opening point
1.8
0 5.5mm0.9
4.5(P)21-2213-1421-2213-14
1.8
0 5.5mm0.9
11-12/21-2213-14/23-2411-12/21-2213-14/23-24
1.8
0 5.5mm3
3.2(P)21-2213-14
3
5.5mm1.8
4.4(P)21-2213-14
3.2(P)
5.5mm1.8
11-1221-22 5.5mm1.8
13-1423-24
1.8
0 5.5mm0.9
4.5(P)11-1221-2211-1221-22
1.8 4.5(P)
5.5mm
13-1431-3221-22
21-2231-3213-14
0 0.9
3.2(P)
5.5mm3
1.821-2231-3213-14
0
1.8 4.5(P)
5.5mm
13-1433-3421-22
21-2233-3413-14
0 0.9
3.2(P)
5.5mm3
1.821-2233-3413-14
0
3.1(A)
0 mm1.5
7.8(P)21-2213-1421-2213-14
3.1(A)
0 mm1.5
11-12/21-2213-14/23-2411-12/21-2213-14/23-24
3.1(A)
0 mm5.2
5.6(P)21-2213-14
3.1
5.2(A) 7.6(P)21-2213-14
mm 3.1(A)
5.6(P)11-1221-22
mm5.5mm3.1(A)
13-1423-24
3.1(A)
0 mm1.5
7.8(P)11-1221-2211-1221-22
3.1 7.8(P)
5.5mm
13-1431-3221-22
21-2231-3213-14
01.5
5.6(P)
mm5.2
3.121-2231-3213-14
0
3.1 7.8(P)
mm
13-1433-3421-22
21-2233-3413-14
0 1.5
5.6(P)
mm5.2
3.121-2233-3413-14
0
0
21-2213-1421-2213-14
0
11-12/21-2213-14/23-2411-12/21-2213-14/23-24 0
21-2213-14
21-2213-14
11-1221-22
13-1423-24
0
11-1221-2211-1221-22
23˚ 58˚(P)
80˚
13-1431-3221-22
21-2231-3213-14
11˚0
42 (̊P)
80˚33˚0
23˚21-2231-3213-14
23˚ 58˚(P)
80˚
13-1433-3421-22
21-2233-3413-14
0 11˚
0
42 (̊P)
80˚33˚
23˚21-2233-3413-14
0
21-2213-1421-2213-14
0
11-12/21-2213-14/23-2411-12/21-2213-14/23-24 0
21-2213-14
21-2213-14
11-1221-22
13-1423-24
0
11-1221-2211-1221-22
23˚
80˚
13-1431-3221-22
21-2231-3213-14
0 11˚
0 80˚33˚
23˚21-2231-3213-14
23˚
80˚
13-1433-3421-22
21-2233-3413-14
0 11˚
0 80˚33˚
23˚21-2233-3413-14
0
21-2213-1421-2213-14
0
11-12/21-2213-14/23-2411-12/21-2213-14/23-24 0
21-2213-14
21-2213-14
11-1221-22
13-1423-24
0
11-1221-2211-1221-22
23˚ 58˚(P)
80˚
13-1431-3221-22
21-2231-3213-14
11˚0
42 (̊P)
80˚33˚0
23˚21-2231-3213-14
23˚ 58˚(P)
13-1433-3421-22
21-2233-3413-14
0 80˚11˚
0
42 (̊P)
80˚33˚
23˚21-2233-3413-14
0
21-2213-1421-2213-14
0
11-12/21-2213-14/23-2411-12/21-2213-14/23-24 0
21-2213-14
21-2213-14
11-1221-22
13-1423-24
0
11-1221-2211-1221-22
30˚
80˚
13-1431-3221-22
21-2231-3213-14
14˚0
80˚40˚0
30˚21-2231-3213-14
30˚
13-1433-3421-22
21-2233-3413-14
014˚
0 40˚
30˚21-2233-3413-14
3231
2221 13
14
222123
24121113
14
3231
2221 13
14
222123
24121113
14
3231
2221 13
14
121113
14 222123
24
1
2
3
4
5
6
7
8
9
10
5 5
1/99
5 5
Limit switches 0 OsiSense XC Standard, format EN 50041Plastic, double insulated, type XCK S Conforming to CENELEC EN 50041 Adaptable sub-assemblies
Dimensions
Plunger headsZCK D01 ZCK D019 ZCK D02 ZCK D029
Rotary headsZCK D31, D33, D34 ZCK D39 ZCK D41 ZCK D49
ZCK D54, D55, D59 ZCK D81 ZCK D91
ZCK (1) rod (2) (3) (4) (5)D54 U 3, L = 125 115 max. 137 max. 49 24D55 Ø 3, L = 125 115 max. 137 max. 49 24D59 Ø 6, L = 200 190 max. 212 max. 46.5 26.2 Note: operatingleverspindlethreadedM6.
Multi-directional heads Bodies with contactsZCK D06 ZCK D08 ZCK S1, S2, S5, S6, S7, S8, S9
ZCK S1H29, S2H29, S5H29, S6H29, S7H29, S8H29, S9H29ZCK SD3p, SD3pH29
ZCK S404, S404H29
(1)1tappedentryforISOM20x1.5orPg13.5cablegland.Ø:2elongatedholesØ5.3x7.3.
16
36.5
36.5
16
4
16
49.5
49.5
4
1641
63
6
55
39
60
10
57
65
54.5
76.5
6 45
53
58
29.5
...84
51.5
...10
6
65
10
57
45...
99.5
67...
121.
5
57
(4) (5)
(2)
(3)(1)
5 53
113.
5
5 53
179
16
144
1.2 16
131
29.536
(1)
72.5
3040
==
6.5
60
2xØ5.8
Ø
29.5
57
98.5
(1)
10
32
30
40
==
60
M6
Ø
2xØ5.3
1
2
3
4
5
6
7
8
9
10