www.powerware.com 1.800.356.5794 1
Introduction and overviewWithanunprecedentedlevelofpowerperformance,reliability,andenergysavings,thestate-of-the-art
Powerware9395UPShasraisedthebarinthree-phasepowerprotectiontechnology.AsITmanagers,
facilitymanagersandCIOsfeelincreasingpressuretoachievezerodowntime,andavailability
requirementsrise,thesearchforthemostreliableandefficientpowerprotectionsystemhasbecome
evenmorecritical.Butthatsearchisnowover.Formorethan40years,Eaton®hasbeendedicatedto
deliveringthemosttechnologicallyadvancedproductsforourcustomers’mission-criticalapplications-
-acommitmentexemplifiedbythenewPowerware9395.Morethananinnovative,cutting-edgeUPS,
it’saquantumleapinthree-phasetechnology.
ThePowerware9395deliversawidescopeofsuperiorcustomer-drivenbenefitsunmatchedby
competitiveUPSsolutions,including:
• Best total reliability:Isolatescriticalloadsfrompowerdisturbanceswiththehighestlevelof
protectionpossibleusingprovendouble-conversiontechnologyandatrulyredundantdesign
• Unmatched green power performance: Providesthehighestelectricalandcoolingsavingsthrough
unrivaledpowerperformanceforefficiency,inputcurrentharmonicdistortion(THD),andpowerfactor
• Scalable, redundant architecture meets current and future load requirements:Growswithchanging
powerrequirementsusingscalablearchitecturethatallowsuserstoaddanother275kVAmodule
on-sitelaterforcapacityorredundancy
• Integrates into total PowerChain Management™ solution from Eaton:OperateswithPowerXpert®
ArchitecturetoenableseamlessmonitoringandmanagementoftheUPSandtheentirepower
system,includingallupstreamanddownstreamswitchgear
Key applications • Largedatacenters• Serverfarms• Telecommunicationinstallations• Internetserviceproviders• Transportationsystems• Securityoperations• Broadcastingandentertainment• Processcontrolequipment• Financialsystems• Creditcardoperations• Medical/healthcare• Industrialsystems
Best total reliabilityWhenitcomestoreliability,
thePowerware9395leaves
competitiveUPSsinthedust.
Providinghighavailability
foryourcriticalsystemsatall
times,thePowerware9395
wasdesignedwithnumerous
technologicaladvancementsthat
createanunprecedentedlevelof
reliability.
Double-conversion design offers the highest protection possible Unlikesomeothercommercially
availableUPStechnologies,
thedouble-conversiondesign
completelyisolatesoutput
powerfromallinputpower
anomaliesanddelivers100-
percentconditioned,perfect
sine-waveoutput—regulating
bothvoltageandfrequency.
Evenwhenpresentedwiththe
mostseverepowerproblems,
poweroutputremainsstable.
OutputvoltageTHDisheld
withintwopercentofnominal
specificationforlinearloads,
andwithinfivepercentfor
nonlinearloads—makingthe
Powerware9395idealfor
supportingequipmentthatis
sensitivetoadistortedvoltage
inputasaresultofharmonic
loads.Intheeventofautility
powerfailure,thereisnodelay
transferringtobackuppower.
Inherent redundancy option Surveysfocusedonefficiency
indatacentersrevealthat
UPSsareoftenunder-
loaded–frequentlyatless
than50percent.Tocapitalize
onthistrendandcreate
evengreaterreliability,you
havetheoptiontoconfigure
thePowerware9395with
inherentredundancy.With
thisredundantconfiguration,
thePowerware9395becomes
inherentlyredundantwhenthe
loadisat50%orbelowofthe
UPScapacity.TraditionalUPS
manufacturerscannotdeliver
thisadditionalreliabilitywithout
addingamorecostlysecond
UPSmodule.
Inherent redundancy option:When at or below 50% capacity, the Powerware 9395's UPMs automatically share the load
� EATON CORPORATION Three-phaseUPSSolutions
Powerware Hot Sync® technology: The culmination of power reliabilityInconfigurationswithmorethanoneuninterruptiblepower
module(UPM),thePowerware9395leveragestheautomaticload
sharingcapabilitiesofEaton’spatentedPowerwareHotSync
technology.PowerwareHotSyncenablestheUPMstosharethe
loadequally,eliminatingtransfertimewhenshiftingtheloadfrom
onemoduletotheother.Theloadsharecontrolalgorithmsmaintain
synchronizationandloadbalancebyconstantlymakingminute
adjustmentstovariationsintheoutputpowerrequirements.
WhentwoormoreUPMsoperateinparallelforcapacityand
redundancy,PowerwareHotSyncaddressesthetwoprimary
concernsofloadsharingandselectivetripping.Toaddressthetwo
primaryconsiderationsforreliability--thedegreeofautonomyand
thecomplexityofimplementation--PowerwareHotSynctechnology
combinesdigitalsignalprocessingandanadvancedcontrol
algorithmtoprovideautomaticloadsharingandselectivetrippingin
aparallelsystem,aswellascompleteautonomyofthemodulesand
askillfullysimpleimplementation.Optimumreliabilityandflexibility
areachievedwiththefollowingdesignfeaturesinaPowerwareHot
Syncparalleledsystem:
• Unlikeotherparallelingtechniques,thereisnosystem-levelsingle
pointoffailure
• PowerwareHotSyncsystemsarecapableofparallelingforboth
redundancyandcapacity
• Byusingapeerconfiguration,asopposedtoa“master-slave”
configuration,PowerwareHotSyncensuresthateachmoduleis
operatingindependently
• Noaddedcircuitryorcomponentsarerequiredtobe“switched
in”tooperateinparallel
• Withthousandsofsuccessfulsystemsinstalledaroundtheworld,
PowerwareHotSyncisaproventechnology
Powerware Sync Control technology PowerwareSyncControlensuresthattheoutputoftwo(ormore)
separateUPSs(singlemoduleorparallelsystems)remaininphase
withoneanothersostatictransferswitchesconnectedbetween
theseparatedistributionpathsmaychangestateseamlesslywhen
necessary.
Powerware Static Auto Tie ThePowerwareStaticAutoTie(SAT)systemenhancesreliability
evenfurthersofullloadtransferscanbemadeautonomously.The
PowerwareSATsystemaddsawrap-aroundstaticswitchtothetie
breakerinthePowerwareHot-Tie®system,thenaddsintelligent
controlssoapowerprotectionsystemmadeupoftwoormore
separateUPSsystemscanautomatically transfer entireloadsin
theeventoftraumatic,catastrophicfailureofonesystem-ararebut
costlycircumstance.
IntheStaticAutoTieconfigurationdisplayedinthediagramat
right,thereisa"hot-tie"circuitbetweentheoutputsofthetwoUPS
modulesthatautomaticallytransferstheloadsfromonetotheother
asnecessary.Thislesscomplex,dual-patharchitecturestreamlines
thedistributionsystemtoeliminateseriesswitchingandreducethe
potentialdowntimeofsinglepowercordloadsbyupto50percent.
Asaresult,theStaticAutoTiearchitectureoffersanumberof
benefits,including:
• Reducedcapitalexpenses
• Eliminatesneedfortraditional
downstreamstatictransferswitches
• Reducedinstallationcosts
• Increasedsystemreliability
• Increasedsystemefficiency
• Decreasedmaintenancerequirements
• Reducedraisedfloorspacerequirements
Generator
PDU
PDU
PDU PDU
PDU
S TS A TS
Batteries
UPS UPS
A TS
STATIC AUTO TIE
SIS SIS
Static S wit c h Auxiliary Generator
Bus
SBM SBM Auto
Static AutoTie Controls
A TS
TIE
Single P ower Cord L oads Single P ower Cord L oads
Utility S ource A
Utility S ource B Auxiliary Generator
Bus
Dual PowerCord Loads
Fully Deployed Static Auto Tie Configuration
www.powerware.com 1.800.356.5794 3
Batteries: The heart of every UPS WhenautilitypoweroutagecausesaUPStoswitchtobattery
power,itisimperativethatthosebatteriesarehealthy,chargedand
uptothetask.Improperbatterymanagementisthenumberone
causeofdowntime.ManyUPSbatteriesonthemarkettodayare
constantlytrickle-charged—aprocessthateventuallydegradesthe
battery’sinternalchemicalcomposition,reducingpotentialbattery
servicelifebyasmuchas50percent.Toaddressthisconcern,we
haveincorporatedEaton’sABM®technology,whichusesasensing
circuitryandaninnovativethree-stagechargingtechniqueto
significantlyextendbatteryservicelifeandoptimizerechargetime.
Inaddition,optionaltemperature-compensatedchargingmonitors
temperaturesandchanges,andadjuststherateofchargeto
prolongbatterylife.
Monitor batteries for optimum readiness AdvancesinfirmwareanddigitaltechnologyenablethePowerware
9395tooffersophisticatedbatterymonitoringandmanagement
featuresthatyoumightexpecttofindonlyonexpensiveadd-on
systems,including:
• Batteryruntimeremainingmonitorusessystemloadingplus
internalsensingpointsforvoltageandcurrentdatatocalculate
runtimeremaining
• Batterycircuittestperformsaperiodicpulsetestofthebattery
stringtoensurethattherearenoopencircuitsthatwould
jeopardizebatteryperformanceandsystemavailability
Inadditiontotheseintegratedmonitoringfeatures,weoffer
oneyearofsecure,remotemonitoringtoprovide24x7real-time
monitoringofmorethan100UPSandbatteryalarms.Thisreal-time
informationiscriticalinhelpingyoumakemanagementdecisions,
fromschedulingpreventivemaintenancetodeterminingthebest
waytoshedloadsduringanoutage.
Byensuringoptimalbatteryhealthandavailability,battery
monitoringfeaturesraisethereliabilityofthePowerware9395
beyondanyotherUPSinitsclass.
1.RefertotheEatonElectricalInc.LimitedFactoryWarrantyforPowerwarethree-phaseUPSproductsforspecifications,limitations,andterms.Serviceandsupportspecificationsmayvarybycountry.
Service and support enhance performance Eatonrecognizesthatsuperiorpowerreliabilityrequiresflawless
executionfromitsservicesteam.EveryPowerware9395includes
anon-sitestartupfromafactory-trainedfieldtechniciantoinsure
properinstallation,operation,andcustomertraining.Inaddition,
weincludeafullyearofon-site24x7partsandlaborwarrantyand
serviceprotectionplancoverageatnoextracharge.Finally,our
expertswillremotelydiagnose,trend,andproactivelyspotproblems
andexpeditefieldtechnicianswithappropriatepartswhenrequired
duringthefirstyearwithouradvancedeNotifyRemoteMonitoring
Service.IncludedatnoextrachargewitheveryPowerware9395:
• 24x7x365startupserviceandcustomertraining
• One-yearlimitedfactorywarranty1
• Serviceprotectionplan24x7coverage,eight-hourresponse
(upgradetofour-ortwo-hourwhereavailable),partsandlabor,
unlimitedon-siteemergencyresponsesupport
• eNotifyRemoteMonitoringService:24x7critical
alarmnotificationandmonthlyreportsonUPSandbatteryhealth
• 24x7technicalsupportaccess
Inadditiontothewarrantyandfirstyearofon-sitecoverage,Eaton
offersawidevarietyofsupportagreementsforcontinuedpreventive
andemergencyresponsemaintenance.PowerTrustServicePlans
include:
• UPSandbatteryscheduledpreventivemaintenance
• Partsandlaborcoverageforelectronicsand/orbatteries
• Factory-trainedtechnicianswithgenuinePowerwarepartsand
diagnostictools
• eNotifyRemoteMonitoringService
• Availablecoverage:24x7,eight/four/two-hourresponse,or8x5
nextbusinessdayresponse
• 24x7technicalsupportaccess
� EATON CORPORATION Three-phaseUPSSolutions
eNotify Remote Monitoring Service AllPowerTrustServicePlansincludeEaton’seNotifyRemote
MonitoringService,enablingEatonservicetechnicianstoremotely
monitoryourUPSandbatteriesusingone-wayemails.Withtech-
nicalexpertsavailabletorespondimmediatelyandresolvemany
issuesremotely,eNotifyfeatures24x7real-timemonitoringof100+
UPSandbatteryalarms.
TheeNotifyServiceprovidesyouwithmonthlyreportsdetailing
theongoinghealthofyourPowerware9395UPS.TheCustomer
MonitoringReportdeliversinformationonyourunit’svoltages,
loads,andexternalfactorssuchastemperatureandhumidity.
Additionally,thereportprovidesinformationabouttheattachedbat-
teriesandsystemavailability.Allofthesefactorscontributetothe
RelativeHealthIndex(RHI)scorethatallowsyoutocompareyour
unit’shealthtoEaton’soptimumPowerwareUPSoperatinglevels.
Proactivemonitoringisalsoincluded.Uponreceiptofbothstatus
andevente-mails,anomaliesarecheckedforincomingparametric
oreventdatalogs.Ifananomalyisdetected,Eatonanalystsfurther
studythedataforpossibleimpendingfailuresandtakeappropriate
action.ThefollowingcriticalalarmsareprovidedbyeNotify:
• UPSoutputpowerwillturnoffaftertheconfigureddelayperiod
• Lowbatteryalarmpresent
• UPShardwarefaultdetected
• UPSbatterycompletelydischarged
• UPSinverterfaultdetected
• UPSinternallybypassed
• UPSoutputhasbeenturnedoff
• UPSshutdownimminentalarmconditionexists
• Thefailureofoneormorefuseshasbeendetected
• Arelay,contactor,orbreakerhasfailed
TheeNotifyRemoteMonitoringServiceprovidesconfidencethat
EatoniscontinuallywatchingyourPowerware9395andwillcom-
bineitstechnicalresourcesandfieldtechniciansasneededtoquick-
lyrespondtocriticalalarms.
Sentviaemailtoasmanyassixsitecontacts,theeNotifymonthlyCustomerMonitoringReportprovidesasummaryofthetop10performanceandenvironmentalparameters,batteryevents,availabilitypercentage,andcomparativestatusagainstrecommendedspecification.
Unmatched green power performanceTheinnovativedesignofthePowerware9395deliverstheindustry’s
bestperformancecombinationofhighefficiency,lowinputcurrent
distortionandhighpowerfactor.ThePowerware9395operatesat
greaterthan94percentefficiency,reducingutilitycostsandextend-
ingbatteryruntimes.Highersystemefficiencyalsoresultsincooler
operatingconditions,whichreducesfacilityairconditioningcost,
extendsthelifeofUPScomponents,andincreasesoverallreliability,
availability,andperformance.Anewinputcircuitdesignwithinthe
Powerware9395keepsinputcurrentTHDlowandinputpowerfac-
tornearunitywithoutcompromisingoverallefficiency.Asaresult,
theUPSallowsmaximumtransferofpowerbetweenthepower
sourceandtheprotectedloadandisexceptionallycompatiblewith
multiplepowersources,especiallyauxiliarygenerators.Onthe
outputside,theultrahigh-speedswitchingpulsewidthmodulation
(PWM)inverterenablesthePowerware9395toprovideitsfullrated
powercapabilitytotheloadwhethertheloadpowerfactoris0.9
lagging,unity,or0.9leading.
The innovative design of the Powerware 9395 delivers the industry’s best performance combination of high efficiency, low input current distortion and high power factor.
www.powerware.com 1.800.356.5794 5
The importance of system efficiency Todemonstratetheimportanceoftotalsystemefficiencyinrelation
toloadlevel,thegraphbelowshowshowefficiencygenerallydips
asloadleveldecreases.Ingeneral,manufacturerslistanoptimal
efficiencyratingatfullload.Inreality,however,mostthree-phase
UPSsoperatewellbelowfullload.Asaresult,itisextremelyimpor-
tanttoevaluatetheefficiencyofaUPSatlighterloadsasthisgraph
depicts.
Measuring power performance: Efficiency, power factor, and THD Powerperformance,whichismeasuredbysystemefficiency,outputpowerfactor,andTHD,isthefoun-
dationofthePowerware9395.ItistheUPS’srobustcombinationofthesethreeelementsthatmake
itstandoutasthepremierUPSinitsclass.ThetablebelowdemonstrateshowthePowerware9395
comparestocompetitiveUPSmodels.Mostmanufacturersmustuseinputfilters,whichlowertheir
efficiencyratingevenfurtherthanwhatislistedbelow.ThePowerware9395,ontheotherhand,does
notrequireinputfilterstoobtainlessthanfivepercentTHD.Consideringthevalueofjustatwopercent
differenceinefficiencyina550kVAapplication,thePowerware9395willprovidemorethan$10,000in
electricalandcoolingsavingsperyear!
POwERwARE 9395 POwER PERfORmANCE vs. ThE COmPETITION
Model kVA Rating Full Load Efficiency Output Power Factor Input THD at Full LoadPowerware 9395 275 94.5% 0.9 <5%
Competitor A 225 94.0% 0.9 7%
Competitor B 225 93.0% 0.9 7%
Easy load testing ThePowerware9395testsitsentirepowertrainunderfullload
stresswithouttherequirementofanexternalload.Withnoload
connected,thePowerware9395isabletotestallofitspowerhan-
dlingcomponents,includingtherectifier,inverter,contactors,fuses,
powerbusses,cabling,batteries,bypass(staticswitch),magnetics,
andfiltercapacitors.Thenetresultofthisinnovativeloadtestisthat
therearenoloadbankstorent,notemporaryloadconnectionsto
make,andnowastedenergy.Furthermore,thePowerware9395has
theabilitytotesttheupstreambypassinputbreaker(BIB),therecti-
fierinputbreaker(RIB),andalloftheelectricalcablesbetweenthem.
Thisloadtestfeaturecantaketheplaceofsometraditionalload
bankteststosaveyoutimeandmoneyduringstartupandcommis-
sioning.
Eatonfieldtechniciansaretrainedtousethisloadtestingcapability
duringastartupservicetoensureoptimumcalibrationandmaxi-
mumefficiency.Asaresult,theycanproduceareportthatveri-
fiesthesetestsandoverallperformanceoftheUPS.Allpreventive
maintenancevisitsincludedwithPowerTrustServicePlansforthe
Powerware9395includethisuniqueloadtestingfeaturetoensure
thattheUPSisoperatingoptimally.Italsovalidatestheperformance
ofaninstalledUPSandcansimulatevariousoperationsandpower
transfers.
25%80.00%
% Load
Traditional UPS
Efficiency vs. Load
Powerware 9395
82.00%
84.00%
86.00%
88.00%
90.00%
92.00%
94.00%
96.00%
50% 75% 100%
� EATON CORPORATION Three-phaseUPSSolutions
Scalable, redundant architecture meets current and future requirementsThePowerware9395combines
thereliabilityandredundancyof
amulti-moduleUPSintoaninte-
grated,pre-wiredsolution.With
aunique,flexibledesignthat
providesscalability,theUPScan
adapttofuturechangesinload
demandsandnewrequirements
forhigherreliabilitywithout
requiringthepurchaseofan
additionalUPS.Forexample,the
Powerware9395UPSenables
youtoadda275kVAUPMin
thefieldforN+1redundancyor
capacity.
275 kVA UPM 550 KVA ISBM 275 kVA UPM 275 kVA UPM
On-siteUpgrade
Concurrent maintenance: Higher availability WithPowerware9395redundant
models,Eatonfieldtechnicians
cancompletelyisolateandser-
vicearedundantmodulewhile
theothermodulecarriesthe
load--withoutgoingtobypass
forservice.ThePowerware9395
alsofeaturesacompletelyfront-
accessibledesignandcanbe
installedagainstwallsorbackto
backinmulti-moduleconfigura-
tion.Thisservice-friendlydesign
enhancesmaximumuptimeand
availability.
Service this Module
…While this module carries the load
www.powerware.com 1.800.356.5794 7
Ease of installation Traditionalmulti-moduleinstallationsinvolvethreetimestheconnectionsforinter-unitpowerand
communicationscabling.Incontrast,thePowerware9395isacompletelyintegratedlargesystemthat
eliminatestheneedtoinstallinternalconduitstopowermoduleframes.Sinceeverythingispre-wired,
cablingcostsandinstallationtimearesignificantlyreduced.Theillustrationbelowdepictsacomparison
withatraditionalsystem:
Minimized cabling requirements and expense InanintegratedsystemsuchasthePowerware9395,multi-
modulesystemsarrivepre-wiredwithnoneedtoperformcostly
andtime-consuminginter-unitcablingforpowerandcommunica-
tionsbetweenmodulesandthesystembypassunit.Consideringthe
increasingcostforrawmaterialssuchascopper,thissavingscan
besignificant.CablingentersthePowerware9395UPSfromeither
thetoporbottomofthecabinettoprovideeasierandmoreflexible
installation.
Greatly reduced footprint
ThePowerware9395UPSoffersthesmallestfootprintandlowest
weightofanyUPSinitsclass—50to60percentlessthancom-
petitiveunits.Infact,thePowerware9395fitsaredundantdesign
intothesamefootprintasatraditional,non-redundantUPS.The
Powerware9395’ssmallerfootprintnotonlyreducesyourtotalcost
ofownership,butalsoprovidesaUPSthatisapproximatelyhalfthe
weightoflegacyandcompetitivesystems.Asaresult,freightcosts
aremuchlowerandthesmallersizeandweightoftheUPSmake
itmucheasiertohandle.Infact,thePowerware9395fitseasily
throughalldoorsandcanbetransportedonfreightelevators.Unlike
somelargerandheaviersystems,thereisnoneedtodismantleitto
fititonelevatorsorthroughdoorways,whichcancausesignificant
delaysandincreasecosts.
Reliable Eaton components ThePowerware9395leveragesreliableandprovenelectricalcom-
ponentsmanufacturedbyEatonsuchasCutler-Hammercircuit
breakersandcontactors.
+ + VS.225 kVA 225 kVA SBM
or Tie
TraditionalSystem Powerware9395
All the capabilities of a traditional system in a single Powerware 9395 unit
The Powerware 9395 features Cutler-Hammer LG-series input circuit breakers rated at �5 and 100 kAIC
� EATON CORPORATION Three-phaseUPSSolutions
Eaton delivers a new level of confidenceTheculminationof40yearsofR&Dexcellence,thenewPowerware
9395UPSdeliverstheutmostinconfidence—confidencethatyour
organization’scriticalsystemsareprotectedbythemostreliable,
efficient,andfull-featuredprotectionsolutionavailable.Eatonwill
betherewithyoulongterm,withpremiumwarrantycoverageand
experttechnicalsupport.To find out more about the Powerware 9395 UPS, visit our Web site at www.powerware.com/9395 or contact us at 1.�00.35�.579�.
Eaton’s total PowerChain Management solutionEatonviewsyourpowersystemasastrategicasset—anapproach
wecallPowerChainManagement.Eaton’sPowerChainManagement
solutionscanhelptransformcomplicatedpowersystemsinto
asingle,integratedsystemeasilyvisibleandmanageableas
astrategicbusinessasset,providingasignificantcompetitive
advantage.
Ifyourcompanyislikemost,itspowersystemwasbuiltovertime.
Astheorganization’sneedschanged,additionalequipmentwas
likelypiece-mealedintothesystem,withacircuitbreakeradded
hereandatransformerreplacedthere.Theresultcanbeapower
systemthatisacomplicatedmixtureofoldandnewequipment
fromseveraldifferentmanufacturers.Becausethereisnocommon
meansofcommunicatingacrossthisvariedequipment,gathering
dataacrosstheenterprisecanbequitechallenging.
Enhance your business visibility to see the entire picture Thecomplexityofgatheringdataamongvariousdevicesmakesit
difficulttogetaclearpictureofwhat’shappeninginsideyourpower
system,whichdecreasesyourabilitytomanageyourpowersystem
effectively.Consequently,businessresultssuffer,becauseyour
enterprisedependsonitspowersystem.
Eaton’sPowerXpert®Architecture,thebackboneofourPowerChain
Managementsolutions,enablesyoutomonitormuchmorethan
yourPowerware9395UPS;ittransformsyourpowersystemintoan
integrated,agilesystemthatdeliversrealcompetitiveadvantages.
WiththesoftwareandhardwarecomponentsofPowerXpert
Architecture,youcanmonitor,control,andmanageyourcomplete
powersystemeffectivelyandefficiently,includingPDUs,batteries
andothercriticalequipment.Usingasimple,Web-basedinterface,
thevariedelementsofyourpowersystemareintegratedintoa
singleview,withtheabilitytoeasilymonitortheavailabilityand
reliabilityofelectricalpower,lowerenergycosts,extendequipment
life,andmore.
Optimize your power system PowerChainManagementcanalsohelpyoumanageyourpower
systemforpeakperformancebyintegratingandoptimizingyour
powerassetsandensuringthattheyalignwithyourbusinessgoals.
OnceyourpowersystemislinkedtoanEthernetnetworkviathe
PowerXpertArchitecture,youcanconnecttoandshareinformation
withavarietyofapplications,suchasthebuildingmanagement
systemmonitoringyourHVACequipment,oryourenterprise
accountingsystem.PowerXpertArchitecture’sopenstandardsand
scalableapproachmakeiteasyforyourpowersystemtogrowand
adapttoarapidlychangingenvironment.
The ConnectUPS-X Web/SNMP Card allows you to con-nect your Powerware 9395 directly to the Ethernet net-work and the Internet. This unique solution allows you to conveniently monitor and manage your UPS with a standard Web browser. The ConnectUPS Card is also used to take advantage of Eaton's ��x7 eNotify Remote Monitoring Service.
www.powerware.com 1.800.356.5794 9
Core componentsThePowerware9395iscomposedoftwocorecomponents:
A closer look inside the Powerware 9395
Integrated System Bypass Module
(ISBM)
All components for redundant, multi-module
UPS are included
��5 or �75 kVA Uninterruptible Power Module (UPM)
X-Slot® Communications (� slots)
ConnectUPS-X Web/SNMP Card
�-line Backlit
LCD
Input CircuitBreaker Option
Top or Bottom
Entry
Static Bypass(continuous duty)
Base with Inter-unit Cabling
Double-conversion topology converter/inverter section
Redundant PowerSupplies
Redundant Fans
UPM easy service disconnect
ISBM Section UPM Section
AC Input and Output
Connections
Input and Output Contactors
UPS Rating (0.9 power factor)kVA 225 275 450 500 550kW 202 250 405 450 500
General CharacteristicsEfficiency >94%Parallel Capability Up to 3 modules, 550 kVA maximumAudible Noise < 76dBA @ 1 meterAltitude (max) 2000m at 40ºC (104ºF)N+1 Redundancy Capable YesField Upgradeable Yes, 275 kVA incrementsSystem Bypass Module Included
Input CharacteristicsVoltage 480V standard; 208V and 600V with isolation transformer optionsVoltage Range +10% / -15%Frequency Range 45-65 HzPower Factor 0.99 (minimum) Input Current Distortion <5% (no input filter required)Soft Start Capability YesInternal Backfeed Yes Protection
Output CharacteristicsVoltage 480V standard; 208V and 600V with isolation transformer optionRegulation ±1% Inverter PWM with IGBT switchingVoltage THD <2% (100% linear load); <5% (non-linear load)Load Power Factor Range Up to a .9 power factor leading without derating
BatteryBattery Types VRLA, AGM, Gel, WetBattery Voltage 480VTemperature Compensation OptionalCharging Method ABM technology
Dimensions and Weights225 kVA, 275 kVA 52.4”w x 32.7”d x 73.7”h 1786 lb225, 275 kVA + 1 redundant 73.6”w x 32.7”d x 73.7”h 2875 lb450, 500, 550 kVA 73.6”w x 32.7”d x 73.7”h 2977 lb450, 500, 550 kVA 103.0”w x 32.7”d x 73.7”h 4150 lb +1 redundantField installed UPM, 28.8”w x 32.7”d x 73.7”h 1338 lb 225 and 275 kVA
General CharacteristicsControl Panel (LCD) 8 lines x 40 charactersBattery Startup StandardFrequency Conversion StandardMulti-language StandardBuilding Alarm Inputs 5 (galvanic isolated)
OptionsExternal Maintenance BypassPowerware PDU, RPP, and STSExternal Isolation Transformer External Output TransformerMaintenance Bypass ModuleDC Disconnects65 or 100 kAIC Input Breakers
CertificationsSafety UL1778, cULEMC IEC 62040-2, EN50091 Class A (Restricted Access)
eNotify Remote Monitoring24x7 remote monitoring of UPS and battery alarms, daily heartbeat check and monthly report. eNotify requires the ConnectUPS-X Web/SNMP Card and Environmental Monitoring Probe.
CommunicationsSoftware Compatibility: Power Xpert Communications Cards: Four communication bays standard. The following connectivity options can be installed at any time: - ConnectUPS-X Web/SNMP Card (included) - ModBus RTU Card - AS/400 Relay Card - Industrial Relay Card - Powerware HotSync CAN Bridge Card - Environmental Monitoring Probe (included) - Modem CardRemote Inputs/Outputs: Five building alarm inputs and one summary alarm contact (5A @ 120V) standard Remote Monitor Panel: Eight backlit status indicator lamps plus an audible horn
2.Duetocontinuingimprovements,specificationsaresubjecttochangewithoutnotice.
Technical Specifications2
© 2007 Eaton CorporationAll Rights ReservedPrinted in USA9395FXA November 2007
UNITED STATES 8609 Six Forks Road Raleigh, NC 27615 U.S.A. Toll Free: 1.800.356.5794 or 919.872.3020
www.powerware.com/9395
CANADAOntario: 416.798.0112 Toll free: 1.800.461.9166
LATIN AMERICAArgentina: 54.11.4343.6323 Brazil: 55.11.3616.8500 México: 52.55.5488.5252
EUROPE/MIDDLE EAST/AFRICADenmark: 45.3686.7910 Finland: 358.94.52.661 France: 33.1.6012.7400 Germany: 49.7841.666.0 Italy: 39.02.66.04.05.40 Norway: 47.23.03.65.50 Sweden: 46.8.598.940.00 United Kingdom: 44.1753.608.700
ASIA PACIFICAustralia: 61.2.9693.9366New Zealand: 64.0.3.343.3314 China: 86.21.6361.5599 HK/Korea/Taiwan: 852.2745.6682 India: 91.11.2649.9414 to 18 Singapore/SEA: 65.6825.1668
Eaton, Powerware, PowerChain Management, Power Xpert, Powerware, Hot Sync, Hot-Tie, ABM, and X-Slot are trade names, trademarks, and/or ser-vice marks of Eaton Corporation and its subsidiaries or affiliates.