Training on Pasolink Network Management System (Java version)
Technical Center Group
NEC India
Contents
Introduction to Pasolink family
Introduction to Netconfigtoolj
a) Definitions and Basic Operation
b) Creation of configuration files
Introduction to PNMSj
a) Introduction to DCN concepts
b) PNMSj installation and integration
c) Basic operation
PNMSj practicals.
Introduction to Pasolink family
Pasolink Family TreePasolink Family Tree
Introduction to Pasolink Family
Introduction to Pasolink Family
Introduction to Pasolink Family
Introduction to Netconfigtoolj
Main Menu Tool Bar
Network list
Work Area
Main Window
Introduction to Netconfigtoolj
Start a new network configuration. This will delete the current network configuration loaded
on the NetCfgTool.
Select a specific area in the workspace to be printed.
Netconfigtool Shuts down
File Menu
Export Configuration files to the PMC : config files downloaded to the PMC to allow it
to participate in PNMS network
View the list of NE’s that have changes in the configuration file (network.cfg /system.cfg)
Open and existing NetCfgTool file (nct) and load it on the workspace. This will allow you to
work and modify a saved configuration.
.the current configuration in the workspace.
Save The file will be save as *.nct.
.
Introduction to Netconfigtoolj
Edit Menu
Select an NE
Add Network Element in the work space
Add a back-to-back line between NE’s.
Select NE type (Pasolink V3, Pasolink-S, Pasolink+ STM-1, MIU,
Pasolink NEO etc.)
Add a new Network. This will essentially allow you to add another CPMC cluster in
the PNMS.
Copy an existing Network
Modify or edit the Properties of the Selected Network. (Change IP network
address, and or subnet mask.)
Network Menu
Check and create the configuration of the selected
network.
Display the subnet information of the selected network.
Tools Menu
Display NetConfig Tool Manual.
Show the version number of the NetConfig Tool
Help Menu
NE Properties
Right Click on any NE and click properties to display the following window.
The General Tab
NE Properties - Network
The Network Tab
NE Properties - PNMS
PNMS Tab
Network Properties
Right click in the background and select Network properties
The General Tab
Network Properties - Subnet
Create Configuration wizard
Create Configuration wizard
Create Configuration wizard – Changed NE list
Introduction to PNMSj
System Overview
The NEC PNMS is a sophisticated supervisory tool for transmission equipment and allows operator to perform remote system monitor alarms, control NE configuration parameters and display event logging and performance data in either UNIX or Microsoft Windows platform.
Fig. above shows a typical PNMS application. The system consists of a central computer (PNMS PC) and a number of remote data processing nodes called as PM cards. It supervises and controls the Pasolink transmission equipments.
System Components
PNMS : The central site computer is the central operator interface and database from which system operators manage the Pasolink network. It receives the data via PM card, stores it and displays it to the operator in a variety of formats. It accepts command request from the operators and sends them to the on-site equipment for execution. Two types of PNMS can be proposed in accordance with customer’s network size viz : PNMS on Windows NT/2000/XP and the other is PNMS on UNIX OS.
Pasolink Management (PM) Card : PM cards are located at each site in the monitored network to collect alarm and status information from Pasolink and to control that equipment in response to commands from the central site operator. The PMC primary tasks are to control and acquire data from Pasolink at remote location and transfer this data back to the central site. The PM card is designed as plug-in modules.
PM card is functioned as SNMP agent, which detects alarm and status changes in monitored equipment and sends change of notifications to PNMS.
PM card retains the MIB data and transmits a response to “SNMP GET” commands from PNMS and PNMT.
PMC Operation ModesDepending on the size, a network can normally be divided into a number of sub-networks. To
distribute the traffic load we normally define one of the PMC as master and the rest as slaves through discrete design. We also call a master as Central PMC (CPM), a sub-master as Sub-Central PMC (SCPM) and a slave as Remote PMC (RPM).
Even though there is no difference in the hardware design, the PMC will be playing different roles according to the installed software in a NMS as follows :
Master mode (CPM) :
• To get information from the remote sites and to generate reports to the PNMS. The CPM may act as a terminal unit; which processes and then transfers all the physical information of equipment, which is directly connected to the CPM.
• The CPM is connected to PNMS via a dedicated serial communications link, and passes messages received from RPMCs to the PNMS for display.
Sub Master mode (SCPM) :
• Master and gateway function which performs the same activity as a CPM acting as a gateway between CPM and RPM and routing the messages from CPM to RPM and back.
• It also performs a terminal unit function that acts as a stand-alone data acquisition and control unit which processes and then transfers all the physical information of equipment which is directly connected to the SCPM. This function is same as that of RPM.
Slave mode (RPM) :
• It is a stand-alone data acquisition and control unit. It monitors and controls equipments at some remote location. The prime task of RPM is to monitor, control and transfer data back to the central site.
PMC Operation Modes
NEO NE
NEO NE
27
For the TCP/IP communication, each node connected in the network needs to be given an IP address. By interpreting the given IP address, all the nodes can communicate each other.
The form of the IP address is :
- Length : 32 bits
- It consists of two parts
Network Part (Also called Network Address)
Field to identify the logical network
Host Part (also called Host Address)
-Notation
Dividing 32 bits into four 8-bits sections, changing each of them into decimal numbers,
and arraying them in a line with dots separating those numbers (called “dot notation”)
Example : 1100 0011 0000 0000 0001 0010 0011 0100
195 . 0 . 12 . 34
IP Address
28
Classifying IP address (Class A B and C)
IP address are classified according to the values of their most significant 1 to 4 bits.
There are five classes; A, B, C, D and E. The classes D and E are however, used for
special purposes only and are not dealt with. Class A, B and C are explained here. These
three classes are allocated to nodes and devices according to the number of networks and
host computers in a network.
Class A (from 0.x.x.x to 127.x.x.x) Number of networks : 128 (= 2^7)
Number of Host per Network : 16,777,214 (=2^24-2)
All “0” is used to indicate the network
itself and all ‘1” is used for IP broadcast address.
Number of Networks:16,384 (=2^14)
Number of Host per Network : 65,65,534 (=2^16-2)
Number of Networks:
2,097,152 (=2^21)
Number of Host per Network : 254 (=2^8-2)
IP Address
24 bits7 bits0
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
16 bits14 bits1 0
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
8 bits21 bits1 1 0
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
Network Part
Network Part
Network Part
Host Part
Host Part
Host Part
29
IP Address
Class A From 10.0.0.0 to 10.255.255.255.255
Class B From 172.16.0.0 to 172.31.255..255
Class C From 192.168.0.0 to 192.168.255.255
Global IP address and Private IP address
The Global Address refers to the IP address uniquely assigned to a device connected to the Internet and is essential for communicating through the Internet. The Global Address is centrally administered by IANA, under whose jurisdiction the NICs (Network Information Centers) of each country allocates addresses to such organizations as service providers.
The Private Address can be freely allocated within an organization without applying for the allocation to NIC. The address space which never be accessed in the Internet is defined by RFC (Request For Comment) -1918.
INTERNET INTERNETINTERNET
Address Translation at
* NAT/NAPT
Privet IP Address or GlobalIP Address is used
GlobalIP Address is used
Privet IP Address Space
* NAT : Network Address Translation
30
IP AddressSubnet
Since recent trend has accelerated the introduction of LAN, the number of segments (logical networks) in many corporations has significantly increased. However, allocating class-B or class-C addresses will swiftly exhaust the address space. To cope with this situation was created Subnet Address that allows to further subdivide a network address.
A subnet address is a means to expand the number of identifiable networks by using several bits in the host part of the IP address for each class.
In the subnet environment, the network address is handled as the network part plus subnet part, thus expanding the network part by partial use of the host part.
When viewed from outside of the subnet, it looks like a network of the same class.
Network Part Host Part
Network Part Host PartSubnet Part
Interpreted as Network Address
Without Subnet (IP address of class A, B or C
With Subnet
31
IP AddressSubnet Mask
The Subnet Mask is used to identify the boundary of the network part and the host part in the network that divided in to subnets.
The notation of the subnet mask is similar to the IP address. The 32-bit array is divided in to four 8-bit parts, each of which then converted into decimal numbers. These numbers are arrayed in a line with dots placed between them for separation. The part where the bit stream shows continuous “1”s in the subnet mask means the network part. The subnet mask utilized for a node to check if other corresponding computers belong to the same subnet (segment).
Example : The subnet mask of an IP address whose network part consists of first 26 bits.
11111111 11111111 11111111 11000000
( 255 . 255 . 255 . 192 )
Calculation of Network Address from an IP Address and Subnet Mask : Comparison of IP address and subnet mask of the node leads to the network address. The comparison is to be done in the following steps.
IP address (Decimal) : 195 . 125 . 100 . 8
: 255 . 255 . 255 . 192
IP address (Binary) : 11000011 01000101 01100100 00001000 Apply logical AND
Subnet mask (Binary) : 11111111 11111111 11111111 11000000
Network address (Binary) : 11000011 01111101 01100100 00000000
Network address (Decimal) : 195 . 125 . 100 . 0
CIDR (classless inter-domain routing :195. 125. 100. 8/26** Indicates first 26 bits is network address (including subnet)
CIDR (classless inter-domain routing :195. 125. 100. 8/26** Indicates first 26 bits is network address (including subnet)
Network Address(24bits) Host (6bits) Subnet address(2bits)
IP Addresses and Subnets
PNMS (Windows)
PNMS
1
3
Remote Site-A
4 5
Remote Site-B
6 7
Remote Site-C
8
Remote Site-D
2
: RPM
RS232C19.2/9.6kbps, Async
2
Figure7.1 Typical Network Example (Simple trunk line [Physical Model])
1 : CPM
Typical network example
1CPM
2RPM
4RPM
5RPM
6RPM
7RPM
8RPM
3RPM
PNMS
Central Site
172.20.100.1
172.20.100.2
172.20.101.2
172.20.101.3172.20.101.6
172.20.101.4172.20.101.5 172.20.101.7
172.20.101.8
172.20.101.1
Subnet-B (PASOLINK CPM cluster)
Subnet-A (PNMS-CPM Subnetwork)
Figure7.2 Typical Network Example (Simple trunk line [Logical Model])
Typical network example
PNMS
1
3
Remote Site-A
4 5
Remote Site-B
6 7
Remote Site-C
8
Remote Site-D
2
: RPM
RS232C19.2/9.6kbps, Async
2
1 : CPM
R : Router
Figure7.3 Typical Network Example (Simple trunk line [Physical Model])
IPNetwork
R R
Typical network example
1CPM
2RPM
4RPM
5RPM
6RPM
7RPM
8RPM
3RPM
PNMS
Central Site
172.20.100.1
172.20.100.2
172.20.101.2
172.20.101.3172.20.101.6
172.20.101.4172.20.101.5 172.20.101.7
172.20.101.8
172.20.101.1
Subnet-B (PASOLINK CPM cluster)
R
Subnet-A (Router-CPM Subnetwork)
RIP
Network
Figure7.4 Typical Network Example (Simple trunk line [Logical Model])
Typical network example
1CPM
12RPM
PNMS
Subnet-D (PASOLINK CPM cluster)
RIP
Network
Figure7.5 Typical Network Example (Multi-branch network [Logical Model])
R
13RPM
18RPM
3CPM
32RPM
38RPM
33RPM
22RPM
28RPM
23RPM
2CPM
Subnet-A (Router-CPM subnetwork) Subnet-B
Subnet-C
Subnet-E
Subnet-F
Typical network example
Central Site
PNMS (Windows)
1
4
Remote Site-A
5 6
Remote Site-B
Remote Site-C
14
Remote Site-D
3
10 9
12 1113
Remote Site-E
Remote Site-F
Remote Site-G7
82
RS232C19.2/9.6kbps, Async
RS4859.6kbps, Async
Figure 7.6 Typical Network Example (Multi sub-branches network[Physical Model])
: RPM3
1 : CPM
2 : SCPM
Typical network example
1CPM
2SCPM
4RPM
5RPM
6RPM
7RPM
8RPM
3RPM
PNMS
Central Site 14RPM
11RPM
10RPM
9RPM
12RPM
13RPM
172.20.100.1
172.20.100.2
172.20.101.2
172.20.101.3
172. 20.101.6
172.20.101.4172.20.101.5
172.20.101.7
172. 20.101.8
172.20.101.9
Subnet-B(PASOLINK CPM cluster)
Subnet-C
172.20.101.17172.20.101.18172.20.101. 19
172.20.101. 20172.120.101. 21
172.20.101. 22
Subnet-A(Router-CPM Subnetwork)
172.20.101.1
Figure 7.7 Typical Network Example (Multi sub-branches network[Logical Model])
39
Network Size ( Pasolink Family)
Network Elements Allowed
Pasolink NEO Pasolink + Pasolink V3/V4
Number of Regions for 1 central PNMSj 50 50 50
Number of Networks in 1 PNMSj Server 500 500 500
Number of Sub Networks in 1 Network 64 64 32
Number of NEs in 1 Network 500 500 416
Number of NEs in 1 Subnet 1,5,13,29,61 (max) 1,5,13,29,61 (max) 1,5,13(max)
Number of NEs in Multidrop Connection 32 32 14
Network Sizing Rule :
Subnet Mask Subnet Size Available IP Address Number of NEs
255.255.255.252 4 2 1
255.255.255.248 8 6 5
255.255.255.240 16 14 13
255.255.255.224 32 30 29
255.255.255.192 64 62 61
PNMSj Basic Operation
Main Menu
Map: Group Map
Views
Event Log
Main Window
Group View Connection View
Map Views
Event Log Window
User/Group Management Window
Security Window
Link Summary Window
Group Properties Window (Adding new user)
PNMS Properties Window
Active Alarm Window
Alarm History Window
Event Log History Window
Network Configuration Update Wizard (1/6)
Network Configuration Update Window
Network Configuration Update Window
Network Configuration Update Wizard (2/6)
Network Configuration Update Window
Network Configuration Update Wizard (3/6)
Network Configuration Update Wizard (4/6)
Network Configuration Update Window
Network Configuration Update Wizard (5/6)
Network Configuration Update Window
Network Configuration Update Wizard (6/6)
Network Configuration Update Window
Network Configuration Update Window
Network Configuration Finish
Configuration files Downloading
Configuration files Downloading
This function is used to download configuration files created by the NetConfig Tool to the PM Card in the selected NE.
There are two files created for each NE – MIB.cfg and Network.cfg.
MIB.cfg contains file contains relevant information about the equipment (i.e. name, pm type, etc.) and housekeeping (Aux. I/O).
Network.cfg contains the IP address of the target NE as well as the IP address of the opposite NE and the information about the network where the target NE is located.
Click on the CONFIGURATION FILE button under the DOWNLOAD (PC>>PMC) in the PMC window to open the Download Configuration file window.
Configuration files Downloading
Configuration files Downloading
Select each type of config file one by one from the type window
Browse and select the path location to the file selected in the type window
Click execute button to download the selected config file
Repeat the download procedure for the other config file.
A message window indicates the status of the download operation and it will close automatically once the operation is over.
Configuration files Downloading
Configuration files Downloading
After the successful download of the configuration files, click UPDATE button. Update Configuration File window opens.
Select the appropriate box for the type of configuration file(s) that will be updated.
Click OK button to start the update operation.
While updating CFG file, PMC to PMC communication will be lost when PMC initializes to the new system configuration. During this time, PNMT connection to the Pasolink will be lost but will be automatically be reconnected after the PMC resets.
64
Thank You