TO INSTALL: 1. Dig a hole to appropriate depth allowing for rough-in-section to
be secured to conduit.
2. To install with door flush to finish grade: 2a. Mount Rough-in-Section (RIS) with flush pour shield placed at finish grade.
Leave temporary cover plate in place while installing housing.
Flush Pour Shield
Temporary Cover Plate
Rough-in-Section (RIS)
Rough-in-Section (RIS)
Rough-in-Section (RIS)
Flush Pour Shield
TemporaryCover Plate
Pour Screw
Finish Grade
DoorFinish Grade
Finish Grade
Enlarged detail with door installed.
Enlarged detail with temporary cover plate and flush pour shield.
Rough-in-Section (RIS) before pouring finish grade
Rough-in-Section (RIS) after pouring finish grade
Temporary Screws
1
Installation should be performed by a qualified electrician in accordance with the National Electrical Code
and relevant local codes.INSTALLATION INSTRUCTIONS
PARADOX SERIESPDX7
©2014 Acuity Brands Lighting, Inc.7/14/14INS-PDX7
NOTE: Hydrel Reserves The Right To Modify Specification Without Notice. Any dimension on this sheet is to be assumed as a reference dimension: “Used for information purposes only. It does not govern manufacturing or inspection requirements.” (ANSI Y14.5-1973)
20660 Nordhoff St., Suite B | Chatsworth, CA 91311Phone: 866.533.9901 | Fax: 866.533.5291
www.hydrel.com
3. To install with Rough-in-Section (RIS) flush to finish grade: 3a. Remove flush pour shield from Rough-in-Section (RIS). 3b. Re-attach temporary cover plate onto Rough-in-Section (RIS). 3c. Mount Rough-in-Section with temporary cover plate placed at finish grade.
Temporary Screws
Flush Pour Shield
Temporary Cover Plate
Rough-in-Section(RIS)
Door Screw
Finish Grade
Temporary Cover Plate
Rough-in-Section (RIS)
Rough-in-Section (RIS)
Finish Grade
DoorFinish Grade
1/8”Enlarged detail with temporary cover plate.
Enlarged detail with door installed.
Rough-in-Section (RIS) before pouring finish grade.
Rough-in-Section (RIS) after pouring finish grade.
2
Installation should be performed by a qualified electrician in accordance with the National Electrical Code
and relevant local codes.INSTALLATION INSTRUCTIONS
PARADOX SERIESPDX7
©2014 Acuity Brands Lighting, Inc.7/14/14INS-PDX7
NOTE: Hydrel Reserves The Right To Modify Specification Without Notice. Any dimension on this sheet is to be assumed as a reference dimension: “Used for information purposes only. It does not govern manufacturing or inspection requirements.” (ANSI Y14.5-1973)
20660 Nordhoff St., Suite B | Chatsworth, CA 91311Phone: 866.533.9901 | Fax: 866.533.5291
www.hydrel.com
REBAR
CONDUIT
CONDUIT
CAUTION: When installing in organic mulch, surround rough-in section with approximately six inches (15cm) of sand or other non-organic substance.
Install fixture flush per step 2 / 3.
Secure rough-in section to rebar to prevent “floating.”
Install suitable thread sealing compound
when connecting conduit (side or bottom
entry).
4. For optional rebar anchoring: Secure rebar as shown (rebar by others). **Do not penetrate the housing when securing re-bar.**
FINISH GRADE
3
Installation should be performed by a qualified electrician in accordance with the National Electrical Code
and relevant local codes.INSTALLATION INSTRUCTIONS
PARADOX SERIESPDX7
©2014 Acuity Brands Lighting, Inc.7/14/14INS-PDX7
NOTE: Hydrel Reserves The Right To Modify Specification Without Notice. Any dimension on this sheet is to be assumed as a reference dimension: “Used for information purposes only. It does not govern manufacturing or inspection requirements.” (ANSI Y14.5-1973)
20660 Nordhoff St., Suite B | Chatsworth, CA 91311Phone: 866.533.9901 | Fax: 866.533.5291
www.hydrel.com
8. Loosen junction box screw and remove lid. IMPORTANT NOTE: DO NOT lose screw assembly. Screw assembly contains sealing gaskets. It MUST be used to reinstall junction box lid in Step 10.
9. Pull electrical supply conductors and make wire splice in accordance with NEC.
10. Reinstall junction box lid with gas-keted screw provided. Ensure screw is straight, mis-threading can cause leaking. CAUTION: TIGHTEN MINIMUM (35 IN-LBS OR 3.95 n-M).
Temporary Screws
Flush Pour Shield
Temporary Cover Plate
Rough-in-Section (RIS)
Junction Box
Junction Box
Rough-in-Section (RIS)
3/4” NPT
5. Connect 3/4” NPT conduit to junction box (side or bottom entry). Seal con duit entry using suitable thread sealing compound to ensure conduit is watertight and to prevent moisture penetration from conduit system.
6. Pour concrete to finish grade or backfill with dirt.
7. Remove temporary cover and flush pour shield. Remove 3 set screws 120° apart.
4
Installation should be performed by a qualified electrician in accordance with the National Electrical Code
and relevant local codes.INSTALLATION INSTRUCTIONS
PARADOX SERIESPDX7
©2014 Acuity Brands Lighting, Inc.7/14/14INS-PDX7
NOTE: Hydrel Reserves The Right To Modify Specification Without Notice. Any dimension on this sheet is to be assumed as a reference dimension: “Used for information purposes only. It does not govern manufacturing or inspection requirements.” (ANSI Y14.5-1973)
20660 Nordhoff St., Suite B | Chatsworth, CA 91311Phone: 866.533.9901 | Fax: 866.533.5291
www.hydrel.com
11. Ensure power module and incoming power are compatible voltages. Insert power supply module (HID Ballast, Fluorescent Ballast, LED Power Supply, Low Voltage Transformer) into hous-ing. Connect using Hydrel pro-vided silicone filled wire nuts to pre-installed housing wiring.
Power Supply Module
SUPPLY POWER - LINE VOLTAGE
0-10 LOW VOLTAGE DIMMING LINE-+
LED DIMMING
PDX7 WIRING
DRIVER
SPLICE SPLICE SPLICE
WICKING BARRIER
SUPPLY POWER
LINE VOLTAGE
DRIVER
-+
SPLICE
JUNCTION BOX
WICKING BARRIER
JUNCTION BOX
5
Tie all 3 black wires from LED array together
Tie all 3 black wires from LED array together
Installation should be performed by a qualified electrician in accordance with the National Electrical Code
and relevant local codes.INSTALLATION INSTRUCTIONS
PARADOX SERIESPDX7
©2014 Acuity Brands Lighting, Inc.7/14/14INS-PDX7
NOTE: Hydrel Reserves The Right To Modify Specification Without Notice. Any dimension on this sheet is to be assumed as a reference dimension: “Used for information purposes only. It does not govern manufacturing or inspection requirements.” (ANSI Y14.5-1973)
20660 Nordhoff St., Suite B | Chatsworth, CA 91311Phone: 866.533.9901 | Fax: 866.533.5291
www.hydrel.com
14. Ensure the sealing surface and all screw holes are free from debris and thouroughly cleaned before installing the door. Remove three of the eight temporary set screws located at the upper ring of the fixture body and discard.
15. Install door lens assembly ensuring screws are tight.NOTE:Torque the three door screws of the PDX7 between 22in-lbs and 25in-lbs.
Tighten screws until the bottom of the door touches the top of the housing. Tighten screw extra 1/16 to 1/8 turn beyond contact point.
Screw is made with a premium heat treated stainless steel with Teflon coating. This heat treatment gives this screw a greater ultimate strength than standard 18-8.
Door Lens Assembly
12. Install lamp module. Connect to modular power supply using Hydrel provided silicone filled wire nuts.
13. Adjust lamp/reflector as-sembly to aim. Secure with locking/aiming screws.
Lamp Module
6
Installation should be performed by a qualified electrician in accordance with the National Electrical Code
and relevant local codes.INSTALLATION INSTRUCTIONS
PARADOX SERIESPDX7
©2014 Acuity Brands Lighting, Inc.7/14/14INS-PDX7
NOTE: Hydrel Reserves The Right To Modify Specification Without Notice. Any dimension on this sheet is to be assumed as a reference dimension: “Used for information purposes only. It does not govern manufacturing or inspection requirements.” (ANSI Y14.5-1973)
20660 Nordhoff St., Suite B | Chatsworth, CA 91311Phone: 866.533.9901 | Fax: 866.533.5291
www.hydrel.com
LAMP ADJUSTMENT DETAIL
1. Loosen two tilt screws. 2. Tilt lamp.
3. Tighten two tilt screws.
4. Lock rotational ring screw.