1
WOODBURNING FIREPLACE
Fire Risk.
WARNING
For use with solid wood fuel only.Other fuels may overfire and generate poisonous gases (i.e. carbon monoxide).
Model(s):• DO NOTstoreorusegasolineorotherflam-mablevaporsandliquidsinthevicinityofthisoranyotherappliance.
• DO NOToverfire.Overfiringwillvoidyourwarranty.
• Complywithallminimumclearancestocom-bustiblesasspecified.Failuretocomplymaycausehousefire.
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury, or death.
Owner’s ManualOperation and Care
WARNINGHOT SURFACES!GlassandothersurfacesarehotduringoperationANDcooldown.
Hot glass will cause burns.• DO NOTtouchglassuntilitiscooled• NEVERallowchildrentotouchglass• Keepchildrenaway
• CAREFULLY SUPERVISE children in same room asfireplace.
• Alertchildrenandadultstohazardsofhightemperatures.
High temperatures may ignite clothing or other flammable materials.• Keep clothing, furniture, draperies and other flammablematerialsaway.
INSTALLER: Leave this manual with party responsible for use and operation.OWNER: Retain this manual for future reference.
NOTICE: DO NOT discard this manual!
Contact your dealer with questions on installation, operation, or service.
Installation and service of thisapplianceshouldbeperformedbyqualifiedpersonnel.Hearth&HomeTechnologies recommendsHHTFactory Trained or NFI certifiedprofessionals.
Majestic Designer Series • DSR36 Owners Manual • 4012-131 • Rev B • 03/28/16
DSR36
2
Safety Alert Key:• DANGER! Indicatesahazardoussituationwhich,ifnotavoidedwillresultindeathorseriousinjury.• WARNING!Indicatesahazardoussituationwhich,ifnotavoidedcouldresultindeathorseriousinjury.• CAUTION! Indicatesahazardoussituationwhich,ifnotavoided,couldresultinminorormoderateinjury.• NOTICE:Indicatespracticeswhichmaycausedamagetothefireplaceortoproperty.
Table of Contents1 Welcome
A.Congratulations 3B.LIMITEDLIFETIMEWARRANTY 4
2 Product Specific and General Information A.ApplianceCertification 6B.VentedGasLogSets,GasInserts,GasLogLighters andWood-burningInserts 6
3 Important Safety and Operating Information A.FireplaceSafety 7
1.ClearSpace 72.Grate 83.Refractory 84.Firescreen 85.FlueDamper 86.GlassDoors 87.Over-FiringYourFireplace 88.ChimneyFire 8
B.GeneralOperatingParts 91.FlueDamper 102.OutsideAir 103.GlassDoors 10
C.Fuel 111.Hardwoodvs.Softwood 112.Moisturecontent 113.Seasoning 124.StoringWood 125.BurningProcess 126.CreosoteFormation 127.ProcessedSolidFuelFirelogs 12
D.FirstFire 12E.LightingInstructions 13
4 Maintenance and Service A.ChimneyInspection 14B.Creosote(Chimney)Cleaning 15C.Grate 16D.GlassCleaning 16E.AshRemoval 16F. Refractory 16
5 Troubleshooting A.FAQs 18
6 Reference Materials A.ServiceParts 20B.Accessories 22C.ContactInformation 24
Majestic Designer Series • DSR36 Owners Manual • 4012-131 • Rev B • 03/28/16
3
Readthismanualbeforeinstallingoroperatingthisfireplace.Pleaseretainthisowner’smanualforfuturereferences.
A. Congratulations
Listing Label Information/Location Themodelinformationregardingyourspecificfireplacecanbefoundontheratingplateusuallylocatedinthecontrolareaofthefireplace.
1 Welcome
Brand:________________________________________________ ModelName:___________________________
SerialNumber:__________________________________________ DateInstalled: __________________________
Fireplace Information:
Local Dealer InformationDEALER: Fill in your name, address, phone and e-mail information here and fireplaceinformationbelow.
DealerName:________________________________________________________
Address:____________________________________________________________
____________________________________________________________
Phone:_____________________________________________________________
E-mail:_____________________________________________________________
SERIAL NO./NUMERO DESERE MODEL/MODELE MFG. DATE
WARNING: RISK OF FIRE DAMAGE. REPLACE GRATE WITH HEARTH & HOME TECHNOLOGIES
FIREPLACE ALSO FOR USEIN MANUFACTURED HOMES YES NO
CLEARANCE TOCOMBUSTIBLES: FIREBOX/
FOYER
IN.MIN.
FAN KIT/KIT DU VENTILATUERMODEL NO.
AMP.
IF INSTALLATION OR OPERATING INSTRUCTIONS ARE MISSING CONTACT: HEARTH & HOME TECHNOLOGIES,7571 215th Street West, Lakeville, MN 55044. P.N. 4021-954A
FIRE CHAMBER INTENDED FOR USE WITH HEARTH & HOME TECHNOLOGIESLISTED FIREPLACE PARTS AND GLASS DOOR KITS. SEE INSTALLATION AND OPERATING INSTRUCTIONS FOR THIS MODEL.
GRATE MODEL/GRILLE MODELE
DEGAGEMENT DES MATEIAUX COMBUSTIBLES:
MMMIN.
AVERTISSEMT:RISQUE DE DOMMAGE PARINCENDIE, REMPLACEZ LA GRILLE AVEC HEARTH & HOME TECHNOLOGIES
CHIMNEY/CHEMNEE2 IN. MIN.
51 MMRATED AT/CAPACITE115 VOLTS, 50/60 HZ
Serial Number
Grate
Fireplace Model
Majestic Designer Series • DSR36 Owners Manual • 4012-131 • Rev B • 03/28/16
CongratulationsonselectingaHHTwoodburningfire-place.TheHHTfireplaceyouhaveselectedisdesignedtoprovidetheutmostinsafetyandreliability.
Astheownerofanewfireplace,you'llwanttoreadandcarefullyfollowalloftheinstructionscontainedinthisOwner'sManual.PayspecialattentiontoallCautionsandWarnings.
ThisOwner'sManualshouldberetainedforfuturerefer-ence.Wesuggestthatyoukeepitwithyourotherimpor-tantdocumentsandproductmanuals.
YournewHHTwoodburningfireplacewillgiveyouyearsofdurableuseandtrouble-freeenjoyment.WelcometotheHHTfamilyoffireplaceproducts!
4
X Moldedrefractorypanels
4021-645H10/15 Page1of2
Hearth & Home TechnologiesLIMITED LIFETIME WARRANTY
Hearth&HomeTechnologies,onbehalfofitshearthbrands(“HHT”),extendsthefollowingwarrantyforHHTgas,wood,pellet,coalandelectrichearthappliancesthatarepurchasedfromanHHTauthorizeddealer.
WARRANTY COVERAGE:HHTwarrantstotheoriginalowneroftheHHTapplianceatthesiteofinstallation,andtoanytransfereetakingownershipoftheapplianceatthesiteofinstallationwithintwoyearsfollowingthedateoforiginalpurchase,thattheHHTappliancewillbefreefromdefectsinmaterialsandworkmanshipatthetimeofmanufacture.Afterinstallation,ifcoveredcompo-nentsmanufacturedbyHHTarefoundtobedefectiveinmaterialsorworkmanshipduringtheapplicablewarrantyperiod,HHTwill,atitsoption,repairorreplacethecoveredcomponents.HHT,atitsowndiscretion,mayfullydischargeallofitsobligationsundersuchwarrantiesbyreplacingtheproductitselforrefundingtheverifiedpurchasepriceoftheproductitself.Themaximumamountrecoverableunderthiswarrantyislimitedtothepurchasepriceoftheproduct.Thiswarrantyissubjecttoconditions,exclusionsandlimitationsasdescribedbelow.
WARRANTY PERIOD:Warrantycoveragebeginsonthedateoforiginalpurchase.Inthecaseofnewhomeconstruction,warrantycoveragebeginsonthedateoffirstoccupancyofthedwellingorsixmonthsafterthesaleoftheproductbyanindependent,authorizedHHTdealer/distributor,whicheveroccursearlier.Thewarrantyshallcommencenolaterthan24monthsfollowingthedateofproductshipmentfromHHT,regardlessoftheinstallationoroccupancydate.Thewarrantyperiodforpartsandlaborforcoveredcomponentsisproducedinthefollowingtable.Theterm“LimitedLifetime”inthetablebelowisdefinedas:20yearsfromthebeginningdateofwarrantycoverageforgasappliances,and10yearsfromthebeginningdateofwarrantycoverageforwood,pellet,andcoalappliances.Thesetimeperiodsreflecttheminimumexpectedusefullivesofthedesignatedcomponentsundernormaloperatingconditions.
Seeconditions,exclusions,andlimitationsonnextpage.
Parts Labor Gas Wood Pellet EPAWood Coal Electric Venting
X X X X X X X
AllpartsandmaterialexceptascoveredbyConditions,
Exclusions,andLimitationslisted
X X X Igniters,electroniccomponents,andglass
X X X X X Factory-installedblowers
X Firepotsandburnpots
5years 1year X X Castingsandbaffles
7years 3years X X X Manifoldtubes,HHTchimneyandtermination
10years 1year X Burners,logsandrefractory
LimitedLifetime 3years X X X X X Fireboxandheatexchanger
X X X X X X X Allreplacementpartsbeyondwarrantyperiod
WarrantyPeriod HHTManufacturedAppliancesandVenting
1Year
ComponentsCovered
3years
2years
90Days
X IgnitionModules
B. LIMITED LIFETIME WARRANTY
Majestic Designer Series • DSR36 Owners Manual • 4012-131 • Rev B • 03/28/16
5
WARRANTY CONDITIONS:• ThiswarrantyonlycoversHHTappliancesthatarepurchasedthroughanHHTauthorizeddealerordistributor.Alistof
HHTauthorizeddealersisavailableontheHHTbrandedwebsites.• ThiswarrantyisonlyvalidwhiletheHHTapplianceremainsatthesiteoforiginalinstallation.•ThiswarrantyisonlyvalidinthecountryinwhichtheHHTauthorizeddealerordistributorthatsoldtheappliance
resides.• Contactyourinstallingdealerforwarrantyservice.Iftheinstallingdealerisunabletoprovidenecessaryparts,contact
thenearestHHTauthorizeddealerorsupplier.Additionalservicefeesmayapplyifyouareseekingwarrantyservicefromadealerotherthanthedealerfromwhomyouoriginallypurchasedtheproduct.
• Checkwithyourdealerinadvanceforanycoststoyouwhenarrangingawarrantycall.Travelandshippingchargesforpartsarenotcoveredbythiswarranty.
This warranty is void if:• Theappliancehasbeenover-firedoroperatedinatmospherescontaminatedbychlorine,fluorine,orotherdamaging
chemicals.Over-firingcanbeidentifiedby,butnotlimitedto,warpedplatesortubes,rustcoloredcastiron,bubbling,crackinganddiscolorationofsteelorenamelfinishes.
• Theapplianceissubjectedtoprolongedperiodsofdampnessorcondensation.• Thereisanydamagetotheapplianceorothercomponentsduetowaterorweatherdamagewhichistheresultof,but
notlimitedto,improperchimneyorventinginstallation.
LIMITATIONS OF LIABILITY:• Theowner’sexclusiveremedyandHHT’ssoleobligationunderthiswarranty,underanyotherwarranty,expressor
implied,orincontract,tortorotherwise,shallbelimitedtoreplacement,repair,orrefund,asspecifiedabove.InnoeventwillHHTbeliableforanyincidentalorconsequentialdamagescausedbydefectsintheappliance.Somestatesdonotallowexclusionsorlimitationofincidentalorconsequentialdamages,sotheselimitationsmaynotapplytoyou.Thiswarrantygivesyouspecificrights;youmayalsohaveotherrights,whichvaryfromstatetostate.EXCEPTTOTHEEXTENTPROVIDEDBYLAW,HHTMAKESNOEXPRESSWARRANTIESOTHERTHANTHEWARRANTYSPECIFIEDHEREIN.THEDURATIONOFANYIMPLIEDWARRANTYISLIMITEDTODURATIONOFTHEEXPRESSEDWARRANTYSPECIFIEDABOVE.
WARRANTY EXCLUSIONS:Thiswarrantydoesnotcoverthefollowing:• Changesinsurfacefinishesasaresultofnormaluse.Asaheatingappliance,somechangesincolorofinteriorand
exteriorsurfacefinishesmayoccur.Thisisnotaflawandisnotcoveredunderwarranty.• Damagetoprinted,plated,orenameledsurfacescausedbyfingerprints,accidents,misuse,scratches,melteditems,
orotherexternalsourcesandresiduesleftontheplatedsurfacesfromtheuseofabrasivecleanersorpolishes.• Repairorreplacementofpartsthataresubjecttonormalwearandtearduringthewarrantyperiod.Theseparts
include:paint,wood,pelletandcoalgaskets,firebricks,grates,flameguides,batteriesandthediscolorationofglass.• Expansion,contraction,ormovementofcertainpartscausingnoise.Theseconditionsarenormalandcomplaints
relatedtothisnoisearenotcoveredbythiswarranty.• Damagesresultingfrom:(1)failuretoinstall,operate,ormaintaintheapplianceinaccordancewiththeinstallation
instructions,operatinginstructions,andlistingagentidentificationlabelfurnishedwiththeappliance;(2)failuretoinstalltheapplianceinaccordancewithlocalbuildingcodes;(3)shippingorimproperhandling;(4)improperopera-tion,abuse,misuse,continuedoperationwithdamaged,corrodedorfailedcomponents,accident,orimproperly/incorrectlyperformedrepairs;(5)environmentalconditions,inadequateventilation,negativepressure,ordraftingcausedbytightlysealedconstructions,insufficientmake-upairsupply,orhandlingdevicessuchasexhaustfansorforcedairfurnacesorothersuchcauses;(6)useoffuelsotherthanthosespecifiedintheoperatinginstructions;(7)installationoruseofcomponentsnotsuppliedwiththeapplianceoranyothercomponentsnotexpresslyauthorizedandapprovedbyHHT;(8)modificationoftheappliancenotexpresslyauthorizedandapprovedbyHHTinwriting;and/or(9)interruptionsorfluctuationsofelectricalpowersupplytotheappliance.
• Non-HHTventingcomponents,hearthcomponentsorotheraccessoriesusedinconjunctionwiththeappliance.• Anypartofapre-existingfireplacesysteminwhichaninsertoradecorativegasapplianceisinstalled.• HHT’sobligationunderthiswarrantydoesnotextendtotheappliance’scapabilitytoheatthedesiredspace.Informa-
tionisprovidedtoassisttheconsumerandthedealerinselectingtheproperappliancefortheapplication.Consider-ationmustbegiventoappliancelocationandconfiguration,environmentalconditions,insulationandairtightnessofthestructure.
4021-645H10/15 Page2of2
Majestic Designer Series • DSR36 Owners Manual • 4012-131 • Rev B • 03/28/16
6
2 Product Specific and General Information
Warning! Risk of Fire! For use with solid wood fuel only.Otherfuelsmayoverfireandgeneratepoisonousgases(i.e. carbon monoxide).
B. Gas Log Sets, Gas Inserts, Gas Log Light-ers and Wood-burning Inserts
• Optional• Vented gas log sets, gas inserts, gas log-lighters or
wood-burninginsertscanbeinstalledinthisfireplace.Followtheinstructionsprovidedwiththeaccessoryforoperation.
Unvented Gas Logs CAUTION! Ifanunventedgasapplianceisinstalledin
thefireplace,thegasappliancemustonlybeoperatedwith the fireplace glass door fully open (if included).Onlyunventedgaslogsetswhichhavebeenfoundtocomplywith thestandard forunventedroomheaters,ANSIZ211.11.2,aretobeinstalledinthisfireplace.Ifanunventedgasapplianceisinstalleditmustincorpo-rateanautomaticshutoffdevice,andmustbeinstalledinaccordancewiththeNationalFuelGasCodeZ223.1,Latestedition.
WARNING! Do Not operateanunventedgaslogsetinthisfireplacewiththechimneyremoved.
Majestic Designer Series • DSR36 Owners Manual • 4012-131 • Rev B • 03/28/16
A. Appliance Certification
ThisfireplacemaybeinstalledinsleepingroomsEX-CEPTinmanufacturedhomes.Ifinstalledwithagaslogset,provisionsfortheNationalFuelGasCodemustbemet.
Thisfireplacehasbeentestedandlistedforusewiththeoptionalcomponentsspecifiedinthismanual.Theseoptionalcomponentsmaybepurchasedseparatelyandinstalledatalaterdate.Anoutsideairkit,gaslogset,gasinsertorgaslog-lightershouldbeinstalledatthetimeoffireplaceinstallation.
Thisfireplacesystemhasbeentestedandlistedinaccor-dancewithUL127andULC-S610standardsbyUnder-writersLaboratoriesInc.forinstallationandoperationintheUnitedStatesandCanada.
7
A. Fireplace SafetyMostproblemsarecausedbyimproperinstallationandop-erationofthefireplace.Toprovidereasonablefiresafety,thefollowingshouldbegivenseriousconsideration:
• Thefireshouldbesupervisedwheneverthefireplaceisinuse.
• An annual inspection should be performed on thefireplacesystem.
• Installatleastonesmokedetectoroneachfloorofyourhometoensureyoursafety.
• InstallaconvenientlylocatedClassAfireextinguishernearthefireplace.
• Deviseapracticedevacuationplan,consistingofatleasttwoescaperoutes.
• Deviseaplantodealwithachimneyfire:- Evacuate.- Notifythefiredepartment.
3 Important Safety and Operating Information
WARNING! Risk of Fire! Hearth &Home Technologiesdisclaims any responsibility for, and the warranty and agencylistingwillbevoidedbythefollowingactions.DO NOT:• operatedamagedfireplace• modifyfireplace• overfire• installanycomponentnotapprovedbyHearth&Home
Technologies• installpartsorcomponentsnotListedorapproved• operate the fireplace without fully assembling all
componentsImproper installation, adjustment, alteration, service or maintenancecancauseinjuryorpropertydamage.
1. Clear SpaceCombustiblematerialsmustnotbestoredonthehearthextension.Roomfurnishingssuchasdrapes,curtains,chairs or other combustibles must be at least 4ft(1219mm)fromthefrontofthefireplace.
Combustiblematerials arematerialsmade of or sur-facedwithanyofthefollowingmaterials:
- Wood - Compressedpaper- Plantfibers - Plastic- Plywood/OSB - Drywall- Anymaterialthatcanigniteandburn,flameproofed
ornot,plasteredorun-plastered.
WARNING! Risk of Fire! Keep combustible materials, gasolineandotherflammablevaporsandliquidsclearofthefireplace.DO NOT:• storeflammablematerialsclosetothefireplace• usegasoline, lantern fuel, kerosene, charcoal lighter
fluidorsimilarliquidstostartor“freshenup”afireinthisfireplace.
48 in. (1219 mm)Clear Space
Front of Fireplace 12 in. (305 mm)Clear Space
Sides of Fireplace(from the FP
opening)
40 3/8 in. (1026 mm)Clear Space
Bottom of Fireplace to Lower Edge of Mantel or Trim
Figure 3.1 Clear Space
Non-combustiblematerialsarematerialswhichwillnotigniteandburn,composedofanycombinationof thefollowing:
- Steel - Iron- Brick - Tile- Concrete - Slate- Glass - Plasters
Majestic Designer Series • DSR36 Owners Manual • 4012-131 • Rev B • 03/28/16
8
8. Chimney FireIntheeventofachimneyfire
• Havethechimneyandadjacentstructureinspectedbyqualifiedprofessionals.Hearth&HomeTechnologiesrecommendsthatNFIorCSIAcertifiedprofessionals,or technicians under the direction of certifiedprofessionals,conductaminimumofanNFPA 211 Level 2 inspectionofthechimney.
• Replacecomponentsofthechimneyandfireplaceasspecifiedbytheprofessionals.
• Ensure all joints are properly engaged and thechimneyisproperlysecured.
WARNING! Risk of Fire! Achimneyfirecanperma-nently damage your chimney system. Failure to re-placedamagedcomponentsandmakeproperrepairscancauseastructurefire.
7. Over-Firing Your Fireplace
WARNING! Risk of Fire! Donotover-fire.Over-firingmay ignite creosote or will damage thefireplaceandchimney.
Symptomsofover-firingmayincludeoneormoreofthefollowing:
• chimneyconnectororfireplaceglowing• roaring,rumblingnoises• loudcrackingorbangingsounds• metalwarping• chimneyfire
Topreventover-firingyourfireplace.DONOT:
• useflammableliquids• overloadwithwood• burntrashorlargeamountsofscraplumber• permittoomuchairtothefire
2. GrateThisfireplaceisdesignedtobeusedwiththesuppliedgrateoroneapprovedbyHHT.
WARNING! Risk of Fire! Use only the factory-sup-pliedintegralgrate.• Keepslogsinplace.• Allowsproperaircirculationaroundthefire.
3. RefractoryTherefractoryissuppliedtocontainheatandprovideanattractiveinterior.
Itwillbreakdownover timeandwillneedoccasionalreplacement. Small hairline cracks and discolorationarenormalanddonotaffectitssafety.
WARNING! Risk of Fire! DO NOT burnfireplacewith-out refractory. Use only refractory supplied by Hearth & HomeTechnologies.
4. FirescreenThe firescreen is provided to control sparks. Keep itclosedwhenthefireplaceinuse.
WARNING! Risk of Fire or Burns!• Screenwillnotpreventburningmaterialsfromfalling
out.• Screenpullsorhandlesmaybehot.
5. Flue DamperThefluedampermustbe in thefullyopenedpositionduringoperationofthefireplace.
WARNING! Risk of Fire and Asphyxiation! Open damperpriortooperatingfireplace.Acloseddamperoverfiresthefireplaceandspillssmokeandflamesinto the room.
6. Glass DoorsGlassdoorsareoptional.
WARNING! Risk of Fire! InstallONLYdoorsapprovedbyHearth&HomeTechnologies.
WARNING! Risk of Fire and Smoke! Fireplace equipped with doors should be operated only withdoors fully open or doors fully closed. If doors are left partlyopen,gasandflamemaybedrawnoutof thefireplaceopening.
Majestic Designer Series • DSR36 Owners Manual • 4012-131 • Rev B • 03/28/16
9
B. General Operating PartsWARNING! DO NOT operatefireplacebeforereadingandunderstandingoperatinginstructions.Failuretooperatefire-placeaccordingtooperatinginstructionscouldcausefireorinjury.
WARNING
Hot glass will cause burns.• DO NOTtouchglassuntilitiscooled• NEVERallowchildrentotouchglass• Keepchildrenaway• CAREFULLYSUPERVISEchildreninsameroomasfireplace.• Alertchildrenandadultstohazardsofhightemperatures.High temperatures may ignite clothing or other flammable materials.• Keepclothing,furniture,draperiesandotherflammablematerialsaway.
HOT SURFACES!
GlassandothersurfacesarehotduringoperationANDcooldown.
Damper Handle Air Kit
Handle
open(out)
close(in)
open
close
Figure 3.2 General Operating Parts
CAUTION! Ifyouexpectthatchildrenmaycomeintocontactwiththisfireplace,werecommendabarriersuchasadecorativescreen.Seeyourdealerforsuggestions.
Majestic Designer Series • DSR36 Owners Manual • 4012-131 • Rev B • 03/28/16
10
3. Glass Doors• Glassdoorsareoptional.• RefertoFigure3.3forhowtoproperlyusethem.
1. Flue DamperRefertoFigure3.2forlocationandoperationofcon-trol.
Beforelightingthefireplace,verifyfullyopenpositionbylookingupfromtheinsideofthefireplace. PARTLY OPEN
INCORRECT FULLY OPEN
CORRECT
PARTLY CLOSED INCORRECT
FULLY CLOSED CORRECT
Figure 3.3 Operating Positions of Bi-fold Doors
RefertoFigure3.2forlocationandoperationofcontrol.
The outside air kit supplies some combustion air foryourfireplace.Itmayhelpreducetheeffectsofnega-tiveairpressure.
Closetheinlettopreventcolddraftswhenthefireplaceisnotbeingused
2. Outside Air
CAUTION! Outside air control handle may be warm. Adjustbeforelightingfire.
Majestic Designer Series • DSR36 Owners Manual • 4012-131 • Rev B • 03/28/16
11
WARNING! Risk of Fire!• DO NOTburnwetorgreenwood.• Wet, unseasonedwood can cause accumulation of
creosote.
Softwoods Hardwoods
• DouglasFir • Oak• Pine • Maple• Spruce • Apple• Cedar • Birch• Poplar• Aspen• Alder
C. Fuel
1. Hardwood vs. SoftwoodYourfireplace’sperformancedependsonthequalityofthefirewoodyouuse.Onespeciesofwoodvariesverylittle to the other in termsof energy content.All sea-soned wood contains about 8,000 BTU’s per pound.Hardwoodshaveagreaterdensity thansoftwoods;apieceofhardwoodwillcontainabout60%moreBTU’sthananequal sizepieceof softwood.A cordof sea-sonedoak(hardwood)wouldcontainabout60%morepotential energy than a cord of seasoned pine (soft-wood).
Most softwoods are coniferous.These are treeswithneedle-like leaves that stay green all year and carrytheir seeds exposed in a cone. Examples of conifer-oustreesareDouglasfir,pine,spruceandcedar.Soft-woods, being more porous, require less time to dry,burn faster and are easier to ignite than hardwoods.Hardwoods are deciduous trees, broadleaf trees thatlose their leaves in the fall. Their seeds are usuallyfoundwithinaprotectivepodorenclosure.Someex-amplesofdeciduoustreesareoak,maple,apple,andbirch.However,itshouldbenotedthattherearesomedeciduoustreesthataredefinitelynotconsideredhard-woods such as poplar, aspen and alder. Hardwoodsrequiremoretimetoseason,burnslowerandareusu-allyhardertoignitethansoftwoods.Obviously,youwilluse the typeofwood that ismost readilyavailable inyourarea.However,ifatallpossiblethebestarrange-mentistohaveamixofsoftwoodandhardwood.Thiswayyoucanusethesoftwoodforstartingthefire,giv-ingoffquickheattobringthefireplaceuptooperatingtemperature.Addthehardwoodforslow,evenheatandlongerburntime.
2. Moisture contentThemajority of the problems fireplace owners expe-riencearecausedby trying toburnwet,unseasonedwood.Freshlycutwoodcanbeasmuchwaterasitiswood,havingamoisturecontentofaround50%.Imag-ineawoodenbucketthatweighsabout8pounds.Fillitwithagallonofwater,putitinthefireboxandtrytoburnit.Thissoundsridiculousbut that isexactlywhatyouaredoing if youburnunseasonedwood.Deadwoodlyingontheforestfloorshouldbeconsideredwet,andrequiresfullseasoningtime.Standingdeadwoodcanbeconsideredtobeabouttwo-thirdsseasoned,ifcutatthedrytimeoftheyear.
Burningwet,unseasonedwoodwillproducelessheatoutputbecause it requiresenergy in the formofheattoevaporatethewater trapped inside.This iswastedenergythatshouldbeusedforheatingyourhome.Thismoisture evaporates in the form of steamwhich hasa cooling effect in your firebox and chimney system.Whencombinedwithtarandotherorganicvaporsfromburningwooditwillformcreosotewhichcondensesintherelativelycoolfireboxandchimney.
Even dry wood contains at least 15% moisture byweight,andshouldbeburnedhotenoughtokeepthechimneyhotforaslongasittakestodrythewoodout-aboutonehour.Totellifwoodisdryenoughtoburn,checktheendsofthelogs.Iftherearecracksradiatinginalldirectionsfromthecenter, it isdry.Ifyourwoodsizzlesinthefire,eventhoughthesurfaceisdry,itmaynotbefullycured.
WARNING! For use with solid wood fuel only.Otherfuelsmayoverfireandgeneratepoisonousgases(i.e.carbon monoxide).
Majestic Designer Series • DSR36 Owners Manual • 4012-131 • Rev B • 03/28/16
12
5. Burning ProcessFirerequiresfuel,airandheat. Ifheat isrobbedfromthefireplaceduring thedryingstage, thenew loadofwoodhasreducedthechancesforagoodcleanburn.Alwaysburndry,seasonedfirewood.
6. Creosote FormationWhenwoodisburnedslowly,itproducestarandotherorganicvaporswhichcombinewithexpelledmoistureto form creosote. The creosote vapors condense inthe relatively cool chimney flueof a newly-startedora slow-burning fire.Asa result, creosote residueac-cumulatesonthefluelining.
When ignited, creosote createsanextremelyhot firewhichmaydamage thechimneyorevendestroy thehouse.
Thechimneyshallbe inspectedat leastannuallybe-forelighting,oronceeverytwomonthsduringheatingseason.
Whencreosotehasaccumulateditshallberemovedtoreducetheriskofachimneyfire.
7. Processed Solid Fuel FirelogsManufacturedfirelogsmaybeusedwiththisfireplace.Hearth&HomeTechnologiesrecommendstheuseofULClassifiedprocessedfuelfirelogs.Followthemanu-facturer’slightingandsafetyinstructions.
Usingfirelogsmayrequiremorefrequentchimney in-spectionsandcleaning.
Donotpokeorstirthelogswhiletheyareburning.Useonly firelogs that have been evaluated for the appli-cation inmanufactured fireplaces and refer to firelogwarningsandcautionmarkingsonpackagingprior touse.
3. SeasoningSeasonedfirewoodisnothingmorethanwoodthatiscuttosize,splitandairdriedtoamoisturecontentofaround20%.Thetimeittakestoseasonwoodvariesfromaroundninemonthsforsoftwoodstoaslongaseighteenmonthsforhardwoods.Thekeytoseasoningwoodistobesureithasbeensplit,exposingthewetinteriorandincreasingthesurfaceareaofeachpiece.A tree thatwascutdownayearagoandnot split islikelytohavealmostashighamoisturecontentnowasitdidwhenitwascut.
Toseasonwood:
• Cutlogstosize• Splitto6in.(152mm)orless• Airdrytoamoisturecontentofaround20% - Softwood-aboutninemonths - Hardwood-abouteighteenmonths
NOTICE: Seasoningtimemayvarydependingondryingconditions.
4. Storing WoodSplittingwoodbefore it isstoredreducesdrying time.The followingguidelinewillensureproperlyseasonedwood:
• Stackthewoodtoallowairtocirculatefreelyaroundandthroughthewoodpile.
• Elevate thewoodpile off the ground to allow aircirculationunderneath.
• Thesmallerthepieces,thefasterthedryingprocess.Anypieceover6in.(152mm)indiametershouldbesplit.
• Woodshouldbestackedsothatbothendsofeachpieceareexposedtoair,sincemoredryingoccursthroughthecutendsthanthesides.Thisistrueevenwithwoodthathasbeensplit.
• Storewoodundercover,suchasinashed,orcoveredwithatarp,plastic,tarpaper,sheetsofscrapplywood,etc.,asuncoveredwoodcanabsorbwaterfromrainor snow, delaying the seasoning process.Avoidcovering thesidesandendscompletely.Doingsomaytrapmoisturefromthegroundandimpedeaircirculation.
D. First FireBeforelightingyourfirstfireinthefireplace,makecertainthat:
• refractoryisinplace• alllabelshavebeenremoved
Majestic Designer Series • DSR36 Owners Manual • 4012-131 • Rev B • 03/28/16
13
WARNING! Risk of Fire! Keep combustible materials, gasolineandotherflammablevaporsandliquidsclearofthefireplace.DO NOT:• storeflammablematerialsclosetothefireplace• use gasoline, lantern fuel, kerosene, charcoal lighter
fluidorsimilarliquidstostartor“freshenup”afireinthisfireplace.
E. Lighting Instructions
NOTICE: Youmustestablishagooddrafttopreventsmokespillageintotheroom.
Thefirstthreeorfourfiresshouldbeofmoderatesizetoallowtheoilsandbinderstobeburnedfromthefireplaceandtherefractoryandpainttocure.Youmaynoticeanin-dustrialodorthefirstfewfires.Thisisconsiderednormal.
Usewell-seasonedwood.
• Openthefluedampertoafullyopenposition.• Place crumpled or twisted paper under the fireplace
grate.• Looselyarrangekindlingorsmallpiecesofwoodtoform
a‘tent’onthefireplacegrate.• Pre-warm the flue toestablishadraft to help reduce
smokespillageduringstart-up.Holdarolleduppieceofburningnewspaperunderthefluedamperforafewmoments.
• Lightthecrumpledpapertoignitethekindling.• Addsmallpiecesofwooduntilahotbedofembershas
beenestablished.• Addaminimumof threeaverage sizepiecesof split
firewood, placed to allow combustion air and flamesbetweenthem.
Majestic Designer Series • DSR36 Owners Manual • 4012-131 • Rev B • 03/28/16
14
4 Maintenance and Service
WARNING! Hot Surfaces!GlassandothersurfacesarehotduringoperationANDcooldown. DO NOTcleanfireplaceuntilitiscooled.
Installationandrepairshouldbedonebyaqualifiedservicetechnicianonly.Thefireplaceshouldbeinspectedbeforeuseandatleastannuallybyaprofessionalserviceperson.
Thefollowingtasksmaybeperformedannuallybythehomeowner.Ifyouareuncomfortableperforminganyofthelistedtasks,please contact your dealer for a ser-vice appointment.
A. Chimney Inspection Frequency: Asnecessary;atleastannuallybefore
lightingfireplace,oronceeverytwomonthsduringheatingseason.
By: Homeowner/ChimneySweep
• Confirm that termination cap remains clear andunobstructed.
• Inspectforblockagessuchasbirdnests,leaves,etc.• Inspectforcorrosionorseparation.• Inspectforcreosoteandremoveasneeded,atleast
everytwomonthsduringtheheatingseason.• Inspectthesystematthefireplaceconnectionand
atthechimneytop.
In theeventofachimneyfire,Hearth&HomeTech-nologiesrecommendsreplacementofthechimneyandinspectionoftheadjacentstructuretotheprovisionsofNFPALevelIIIinspectioncriteria.
WARNING! Risk of Asphyxiation and Fire! Annual inspectionbyqualifiedtechnicianrecommended.
Check: • conditionofdoors,surroundsandfronts • conditionofglassandglassassembly • obstructionsofcombustionandventilationair • obstructionsofterminationcap
Clean: • glass • airpassageways,grilles
Majestic Designer Series • DSR36 Owners Manual • 4012-131 • Rev B • 03/28/16
15
Figure 4.1 Chimney & Termination Cap Cleaning
WARNING! Risk of Fire! IgnitedcreosoteisextremelyHOT. Prevent creosote buildup.
B. Creosote (Chimney) Cleaning Frequency: Asneeded;atleastannuallybeforelight-
ing,oronceeverytwomonthsduringheatingseason.Whencreosotehasaccumulateditshallberemovedtoreducetheriskofachimneyfire.
By: ChimneySweep Tools Needed:Brush,Phillipsscrewdriver
• Whenwood is burned slowly, it produces tar andotherorganicvapors,whichcombinewithexpelledmoisture to form creosote.The creosote vaporscondense in the relatively cool chimney flue of aslow-burning fire.As a result, creosote residueaccumulates on the flue lining.When ignited, thiscreosotemakesanextremelyhotfire.
• Removeallashfromthefireboxandextinguishallhotembersbeforedisposal.Allow thefireplace tocoolcompletely.
• Closethedoortightly.• Removethetopoftheterminationcapasshownin
Figure4.1tocleanthecapandchimney.• Thecreosoteorsootshouldberemovedfromthe
chimneywithabrushspecificallydesigned for thesizeofchimneyinuse.
• Reinstallterminationcap.• Cleanoutfallendebrisfromthefirebox.
Majestic Designer Series • DSR36 Owners Manual • 4012-131 • Rev B • 03/28/16
Chimney
Remove 4 screwsand lift top pan off.
Cap
SlipSection
ST375Square
Termination Cap
Cap
Remove screws, lift top cover.
Top Cover
TR344/TR342Round
Termination Cap
Chase
Cap
1. Remove the 4 screws.2. Remove the screen.3. Remove the baffle.
TS345/TS345PSquare
Termination Caps
TCT375Terra Cotta
Termination Cap
Remove 2 screws fromthe front and back andlift the top off.
Remove 8 screwsand lift top.
DTO/DTS SeriesTermination Cap
Screw
TopTop
Screw
16
F. Refractory Frequency: Asnecessary By: Homeowner
• Inspect condition of brick. Replace if crumbly orotherwisedeteriorated,or if cracksexceed1/4 in.(6mm).
C. Grate Frequency: Aftereachashremoval By: Homeowner
Inspectgratefor:• Warpingorsagging1-1/2in.(38mm)ormore• Brokenwelds• Burn-throughofgratebars
Forsafeoperation,replaceonlywiththeapprovedgratefromHearth&HomeTechnologies.
E. Ash Removal Frequency: Asnecessary By: Homeowner Tools Needed:Coveredmetalcontainer,metal
shovel,fireplacebroom
WARNING! Risk of Fire! DO NOT remove ashes until thefireisoutandthefireplaceiscold.
• Ashesshouldbeplacedinmetalcontainerwithtightfittinglid.
• The closed container of ashes should be placedonanoncombustible floor or on theground,wellawayfromallcombustiblematerials,pendingfinaldisposal.
• If the ashes are disposed of by burial in soil orotherwiselocallydispersed,theyshouldberetainedin the closed container until all cinders havethoroughlycooled.
D. Glass Cleaning Frequency: Asnecessary By: Homeowner Tools Needed:Vinegarorglasscleaner,softtowel
• Cleanglasswithanon-abrasiveglasscleaner.Useadampclothdippedinwoodashesoracommerciallyavailableovencleaner.Removeanyovencleanerresiduewithaglasscleanerorsoapandwater.
Majestic Designer Series • DSR36 Owners Manual • 4012-131 • Rev B • 03/28/16
17
5 Troubleshooting
Start Fire Problems Possible Cause SolutionCan’tgetfirestartedExcessivesmokeorspillageBurnstooslowlySmolders,sizzles
Notenoughkindling/paperornokindling/paper
Usedrykindling,morepaper.Arrangekindling&woodforairmovement.
Damperclosed/notfullyopen Opendamper.Notenoughairforfiretoignite Checkforrestrictedcap/shroud.
Openairkit(ifinstalled).Checkforflueblockage.Pre-warmfluebeforestartingfire(refertostartingfiresection).Checkforadequateventheight(refertochimneyassemblysection).Openwindowbelowthefireplacetowardsthewind.
Woodconditionistoowet,toolarge Usedry,seasonedwood(refertowoodfuelsection).
Bedofcoalsnotestablishedbeforeaddingwood
Startwithpaper&kindlingtoestablishbedofcoals(refertostartingfiresection).
Flueblockagesuchasbirds’nestsorleavesinterminationcap
Havechimneyinspectedforcreosoteandcleanedbyacertifiedchimneysweep.
DowndraftornegativepressureCompetitionwithexhaustdevices
Donotuseexhaustfansduringstart-up(refertonegativepressuresection).Openwindowbelowthefireplacetowardsthewind.
Fireburnstoofast Extremelydryorsoftwood Mixinhardwood.Mixinlessseasonedwoodafterfireisestablished(refertowoodfuelsection).
Noglassdoors Addglassdoorstoslowdownairflow.Overdrafting Checkforcorrectventheight;toomuchverticalheight
createsoverdrafting.Checklocationofventtermination(refertochimneyassemblysection).
Majestic Designer Series • DSR36 Owners Manual • 4012-131 • Rev B • 03/28/16
18
A. FAQs
Ifsmokespillageoccursfromafireplaceopeningwhenthedoorisopen,thereiseitheraleakageintheflue,ablockageintheflue,orsomeconditionisaffectingdraftUnderstandinganddifferentiatingtheconditionswhichcancauseeachofthesekindsofspillageproblemsisessentialtotheirsolution.
• FlueLeakage Check for improperly connected flue joints or a
damaged flue joint in the chimney system.Suchleakagewouldreducedraft(airwouldbedrawninthroughtheleaksratherthanthroughthefireplace).The resultmight be difficult start-up and smokyfiresthatmightspillifotheradversedraftconditionsaccompanythisproblem.
• FlueBlockage Thedampershouldbeopen. Check for objects thatmay have fallen down the
chimney.
Besureyouhaveairavailableforcombustionandthatyourfirewoodisdryandwellseasoned.Buildyourfiresproperlyandaccordingtotheinstructionsgiveninop-eratinginstructions,“StartingaFire”.Besureyourfluesystemisinstalledcorrectlyandthatitistheproperdi-ameterandheight.Checkforthefollowing:
• Allchimneysectionsareproperlyinstalled.• Thechimney iscleanandfreeofcreosoteorsoot
buildup.• Makesureoverhangingtreesandbranchesarecut
backwithintenfeetofthetopofthechimneyandthechimneyisfreeofdebrisfromanimals.
• Ensure the chimney cap is cleanand free of anybuildupofsootorcreosoteifcapisequippedwithasparkarrestorscreen.
• Thewoodbeingusedindryandwellseasoned.
Ifyoustillsuspectyouhavealowdraftproblemitmaybe necessary to increase the volume of air in yourfluesystem.Sincethediameterofyourfluesystemismatchedwiththesizeofthefluecollarandshouldnotbechanged,thentheheightofthesystemmustbein-creased.Addchimneysectionsoneatatimeuntilthedraftimproves.
Insomecases,regardlessofwhatyoudo,itcanstillbedifficulttoestablishtheproperfluedraft.Thisisespe-ciallyevidentwhenusinganexteriorfactory-builtchim-neyorexteriormasonrychimney.Tryholdingaburningrolledupnewspaperasclosetotheflueoutletaspos-sibleforafewminutes,thenlightthepaperunderthekindling.Theheatgeneratedfromtheburningrolledupnewspapershouldhelpgetthedraftestablished.
Stillotherfactorscanaffecthowwellyourfluesystemperforms.Neighboringstructures,highwinds,talltrees,evenhillsidescanaffectaircurrentsaroundthechim-ney.Welldesignedchimneycapsareavailablethatcanhelp.Your fireplace dealer is the local expert in yourarea. He can usually make suggestions or discoverproblems that can be easily corrected allowing yourfireplacetooperatecorrectlyasithasbeendesigned,providingsafeandeconomicalheatforyourhome.
Flue draft is measured as negative pressure in thechimney.Theamountofnegativepressuredetermineshowstrongthedraftis.Thedraftisimportantbecauseitdrawsthecombustionairintothefireplaceandpullsthesmokeoutofthechimney.
Therearethreebasiccriteriaessential inestablishingandmaintainingfluedraft:
• availabilityofcombustionair• heatgeneratedfromthefire• diameterandheightofthefluesystemThesethreefactorsworktogetherasasystemtocreatethefluedraft.Increasingordecreasinganyoneofthemwillaffecttheothertwoandthuschangetheamountofdraftintheentiresystem.
Ifthefireishardtostartandsmokespillsoutofthefire-place,oryoufinditdifficulttoestablishandmaintainamoderatelyhighburnrate,thenthefluedraftistoolowandcorrectivemeasuresmustbetaken.
Hearth&HomeTechnologiesassumesnoresponsibil-ityfortheimproperperformanceofthefireplacesys-temcausedbyinadequatedraftduetoenvironmentalconditions, down drafts, tight sealing construction ofthestructure,ormechanicalexhaustingdeviceswhichwillcreateanegativeairpressurewithinthestructurewherethefireplaceislocated.
Contact your dealer for additional informa-tion regarding operation and troubleshoot-ing. Visit www.majesticproducts.com to find a dealer.
Majestic Designer Series • DSR36 Owners Manual • 4012-131 • Rev B • 03/28/16
19
Another appliance in home also exhaustingair (furnace, fan, dryer, etc.)?
Air register fromfurnace nearfireplace?
Doors openingand closing?Window closedfor start-up?
Outside airclosed?
Overhead fanoperating?
Overhangingtree?
Bird's nestor leaves interminationcap?
Structuralchanges inchimney area?
Creosote buildupin flue?
Strong winds ar
ound chimney termination?
Unsealedcan lights?
Combustion air control
Figure 5.1 Factory-built Fireplaces: Troubleshooting
Majestic Designer Series • DSR36 Owners Manual • 4012-131 • Rev B • 03/28/16
20
6 Reference Materials
A. Service Parts
Majestic Designer Series • DSR36 Owners Manual • 4012-131 • Rev B • 03/28/16
Service Parts DSR36Beginning Manufacturing Date: N/A Ending Manufacturing Date: Active
36” See-thru Woodburning Fireplace
12
1098 11
7
6
5
3
12
16
415
13
14
IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Provide model number and serial number when requesting service parts from your dealer or distributor.
ITEM DESCRIPTION COMMENTS PART NUMBER1 Damper Blade Assembly 228902 Starter Section Assembly 220693 Top Standoffs Qty 4 req 118644 Smoke Shield Qty 2 req SRV20399BK5 Refractory - Back Qty 2 req 133196 Refractory - Side Qty 4 req 13320A7 Firescreen Assembly Qty 4 req 122678 Door Support Qty 2 req SRV4012-035BK9 Refractory - Hearth 13321B10 Ashlip Qty 2 req 2040111 Damper Control 2054912 Grate GR1213 Front Face (Bottom) SRV4012-109BK14 Column (Right or Left) SRV4012-102BK15 Front Face (Top) SRV20400BK16 Drywall Flange Qty 2 req 20429
Additional service parts on following page. 4/16
21Majestic Designer Series • DSR36 Owners Manual • 4012-131 • Rev B • 03/28/16
Service Parts DSR36Beginning Manufacturing Date: N/A Ending Manufacturing Date: Active
(Side of Fireplace)
171918
(Duct not included in kit, sold separately.)
Outside Air Plate Assembly
IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Provide model number and serial number when requesting service parts from your dealer or distributor.
ITEM DESCRIPTION COMMENTS PART NUMBER17 Outside Air Plate Assembly 19081A18 Long Cable Tie Qty 2 req 1995419 Outside Air Shield 33271
Air Kit Fastener Pack 13580Damper Rod 28900Damper Weight 19785ADoor Pivot clips Qty 4 req 31527Door Track (Lower) Qty 2 req SRV4012-002BKDoor Track (Upper) Qty 2 req SRV15425BKFirescreen Handle 10002Firescreen Rod Qty 4 req 11866Gas Access Panel (for use with Air Kit) 31636Nailing Flange Qty 8 req 31190Refractory Retainer Qty 2 req 11847Refractory Standoff Qty 2 req 13327Smoke De ector Qty 2 req 20603Strip Protector Qty 4 req 18320Touch-Up Paint 71479Owner’s Manual 4012-131Installation Manual 4012-130
22
B. Accessories
Doors
DM1036 Bi-fold glass doors with black trimDM1036S Bi-fold glass doors with stainless steel trim
Gas Log SetsGas Log Lighters
Majestic Designer Series • DSR36 Owners Manual • 4012-131 • Rev B • 03/28/16
23
This page intentionally left blank.
Majestic Designer Series • DSR36 Owners Manual • 4012-131 • Rev B • 03/28/16
24
C. Contact Information
– NOTES –
Printed in U.S.A. - Copyright 2012
DO NOT DISCARD THIS MANUAL
CAUTION
• Leave this manual with party responsible for use and operation.
• Important operating and maintenance instructions included.
• Read, understand and follow these instructions for safe installation and operation.
This product may be covered by one or more of the following patents: (United States) 5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471, 5328356, 5341794, 5347983, 5413089, 5429495, 5452708, 5542407, 5890485, 5931661, 5941237, 5947112, 5996575, 6006743, 6019099, 6048195, 6053165, 6145502, 6170481, 6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, 6769426, 6774802, 6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884,7047962, 7216645, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250, 780403, 1418504 or other U.S. and foreign patents pending.
Majestic Designer Series • DSR36 Owners Manual • 4012-131 • Rev B • 03/28/16
Please contact your HHT dealer with any questions or concerns.
Majestic,abrandofHearth&HomeTechnologies7571215thStreetWest,Lakeville,MN55044
www.majesticproducts.com