SS
SS
SS
SS
S S
S
S
S
S
S
E-01
ELECTRICAL
PARTIAL LIGHTING DEMO PLAN
AS SHOWN
2
MARLTON, NJ ELECTRICAL
VJP
MJS
JTB
JTB
O:\61556 M
TL N
JD
OT
Y
0198-00\05_W
OR
K\C
AD
D\H
anover G
arage Lighting\S
HT
S\61556_E
1.dw
g
Last saved 6/8/2009 3:35:34 P
M by P
AT
EL, V
IX
AR
J.
Plot generated 4/27/2017 12:02:47 P
M
1
E-01
PARTIAL LIGHTING DEMO PLAN
SCALE: 1/8"=1'=0"
OF
DATE:SCALE:
PHASE
DRAWING NUMBER
SHEET
DATE:
DRAWN
CHECKED
APPROVED
DESIGNED
CHKD.DRAWNDATE
REVISIONS
NO. APPRVD.
PROJECT NUMBER
MODIFICATION
This drawing is and shall remain the property
of Gannett Fleming, Inc. Any misuse, reuse,
alterations, additions, and/or deletions of
these drawings on project extensions or other
projects shall be at the user's sole risk and
without liability to Gannett Fleming, Inc. In
the event that a conflict arises between the
sealed physical drawings and the electronic
files, the sealed drawings will govern.
© GANNETT FLEMING, INC. 2017
DISCLAIMER
NJDOT HANOVER YARD
GARAGE BAY LIGHTING UPGRADES
JEFFREY T. BYORICK
PROFESSIONAL ENGINEER
N.J. LIC. NO. 24GE04644000
5 EVES DRIVE,SUITE 200
MARLTON, NJ 08053 TEL. (856-396-2226)
CERTIFICATE OF AUTHORIZATION NO. 24GA28032500
DEPARTMENT OF THE TREASURY
PROPERTY MANAGEMENT AND CONSTRUCTION
NEW JERSEY
DIVISION OF
FINAL DESIGN 2
4
4/27/17
61556
KEYED NOTES:
D1
DEMOLISH AND REMOVE EXISTING LIGHT FIXTURES INCLUDING WIRING
BACK TO THE LOCAL SWITCH. EXISTING CONDUIT TO BE RE-USED.
1. SEE COVER SHEET FOR GENERAL NOTES, SYMBOLS AND
ABBREVIATIONS.
GENERAL NOTES:
D2
DEMOLISH AND REMOVE EXISTING LIGHT FIXTURES INCLUDING
WIRING,CONTROL SWITCHES AND CONDUIT BACK TO THE SOURCE PANEL
LPA.
D3
D1
EXISTING PNL PP-1
(120/208V)
EXISTING PNL LPA
(120/208V)
D1
D2
(TYPICAL FOR
STORAGE BAYS)
D1
(TYPICAL FOR
ALL CAGES)
D2
(TYPICAL FOR
STORAGE BAY)
D1
(TYPICAL FOR
ALL CAGES)
A
B
C
1 2 3 4 5 6 7 8 9 10
DEMOLISH AND REMOVE EXISTING EMERGENCY EXIT SIGN INCLUDING
WIRING AND CONDUIT.
D3
D3
A
A
A
A
A
A
A
A
A
A
A A
A
A
A
A
A
A
A
A
A
A A
A
A
A
A
A
A
A
A
A
A
A A
A
A
A
A
A
B
B
B
B
B
B
B
B
B
B
B
B
j
h
h
i
j
k
i
k
i
j
j
k
k
i
i
j
k
i
i
j
k
i
j
k
i
j
k
i
j
a
b
a
b
a
b
c
c
a
b
a
b
b
a
b
g
f
e
d
d
S
e
S
g
S
f
S
a
S
b
S
c
S
h
S
i
S
j
S
k
S
l
m
n
o
l
S
m
S
o
S
n
S
EM
EM
EM
EM
EM
EM
EM
EM
EM
X1 X1
EM1
EM1
E-02
ELECTRICAL
PARTIAL LIGHTING PLAN
AS SHOWN
3
MARLTON, NJ ELECTRICAL
VJP
MJS
JTB
JTB
O:\61556 M
TL N
JD
OT
Y
0198-00\05_W
OR
K\C
AD
D\H
anover G
arage Lighting\S
HT
S\61556_E
2.dw
g
Last saved 6/8/2009 3:35:34 P
M by P
AT
EL, V
IX
AR
J.
Plot generated 4/27/2017 12:04:35 P
M
2
E-01
PARTIAL LIGHTING PLAN
SCALE: N.T.S.
OF
DATE:SCALE:
PHASE
DRAWING NUMBER
SHEET
DATE:
DRAWN
CHECKED
APPROVED
DESIGNED
CHKD.DRAWNDATE
REVISIONS
NO. APPRVD.
PROJECT NUMBER
MODIFICATION
This drawing is and shall remain the property
of Gannett Fleming, Inc. Any misuse, reuse,
alterations, additions, and/or deletions of
these drawings on project extensions or other
projects shall be at the user's sole risk and
without liability to Gannett Fleming, Inc. In
the event that a conflict arises between the
sealed physical drawings and the electronic
files, the sealed drawings will govern.
© GANNETT FLEMING, INC. 2017
DISCLAIMER
NJDOT HANOVER YARD
GARAGE BAY LIGHTING UPGRADES
JEFFREY T. BYORICK
PROFESSIONAL ENGINEER
N.J. LIC. NO. 24GE04644000
5 EVES DRIVE,SUITE 200
MARLTON, NJ 08053 TEL. (856-396-2226)
CERTIFICATE OF AUTHORIZATION NO. 24GA28032500
DEPARTMENT OF THE TREASURY
PROPERTY MANAGEMENT AND CONSTRUCTION
NEW JERSEY
DIVISION OF
FINAL DESIGN 2
4
4/27/17
61556
KEYED NOTES:
1
MOUNT TO BOTTOM OF BEAM.
MOUNT TO WOOD PLATFORM
MOUNT AT 8'-0" AFF ON FENCE.
MOUNT TO STEEL DECK.
MOUNT TO EXISTING HANGER AND UNISTRUT CHANNEL.
1. SEE COVER SHEET FOR GENERAL NOTES, SYMBOLS AND
ABBREVIATIONS.
2. SEE DRAWING E-03 FOR LUMINAIRE SCHEDULE & FIXTURE
MOUNTING DETAILS.
3. ALL LIGHTING CIRCUITS SHALL BE 2-NO.10 AWG & 1-NO. 10
AWG EGC.
4. ALL LIGHTING CONDUIT SHALL BE 3/4" RGS CONDUIT.
5. LIGHTING CIRCUIT LPA/10 AND LPA/12 SHALL BE ROUTED IN
SAME CONDUIT.
6. LIGHTING CIRCUIT LPA/18, LPA/20 AND LPA/22 SHALL BE
ROUTED IN SAME CONDUIT.
GENERAL NOTES:
2
3
EXISTING PNL PP-1
(120/208V)
EXISTING PNL LPA
(120/208V)
A
B
C
1 2 3 4 5 6 7 8 9 10
LPA/20
LPA/22
LPA/18
LPA/20
LPA/22
LPA/28
LPA/28
LPA/28
LPA/28
LPA/22
LPA/18
LPA/20
LPA/22
LPA/18
LPA/20
LPA/22
LPA/18
LPA/20
LPA/22
LPA/18
LPA/18
LPA/20
LPA/22
LPA/18
LPA/20
LPA/22
LPA/18
LPA/20
LPA/22
LPA/18
LPA/20
LPA/15
LPA/15
LPA/10
LPA/12
LPA/10
LPA/12
LPA/10
LPA/12
LPA/13
LPA/28
LPA/28
LPA/28
LPA/28
LPA/10
LPA/12
LPA/10
LPA/12
LPA/12
LPA/12
LPA/10
4
2
2
2
1
(TYPICAL FOR
ALL TYPE "A"
FIXTURES)
3
3
3
3
1
(TYPICAL FOR
ALL TYPE "A"
FIXTURES ON
BEAM)
4
(TYPICAL FOR
ALL TYPE "A"
FIXTURES ON
CEILING)
5
5
5
5
2
LPA/12
LPA/20
LPA/20
LPA/18
LPA/22
LPA/10
LPA/10
LPA/13
LPA/10
LPA/12
LPA/22
5
LPA/12
E-03
SCHEDULES & DETAILS
AS SHOWN
4
MARLTON, NJ ELECTRICAL
VJP
MJS
JTB
JTB
O:\61556 M
TL N
JD
OT
Y
0198-00\05_W
OR
K\C
AD
D\H
anover G
arage Lighting\S
HT
S\61556_E
3.dw
g
Last saved 6/8/2009 3:35:34 P
M by P
AT
EL, V
IX
AR
J.
Plot generated 4/27/2017 12:05:37 P
M
2
E-03
LUMINAIRE SCHEDULE
SCALE: N.T.S.
OF
DATE:SCALE:
PHASE
DRAWING NUMBER
SHEET
DATE:
DRAWN
CHECKED
APPROVED
DESIGNED
CHKD.DRAWNDATE
REVISIONS
NO. APPRVD.
PROJECT NUMBER
MODIFICATION
This drawing is and shall remain the property
of Gannett Fleming, Inc. Any misuse, reuse,
alterations, additions, and/or deletions of
these drawings on project extensions or other
projects shall be at the user's sole risk and
without liability to Gannett Fleming, Inc. In
the event that a conflict arises between the
sealed physical drawings and the electronic
files, the sealed drawings will govern.
© GANNETT FLEMING, INC. 2017
DISCLAIMER
NJDOT HANOVER YARD
GARAGE BAY LIGHTING UPGRADES
JEFFREY T. BYORICK
PROFESSIONAL ENGINEER
N.J. LIC. NO. 24GE04644000
5 EVES DRIVE,SUITE 200
MARLTON, NJ 08053 TEL. (856-396-2226)
CERTIFICATE OF AUTHORIZATION NO. 24GA28032500
DEPARTMENT OF THE TREASURY
PROPERTY MANAGEMENT AND CONSTRUCTION
NEW JERSEY
DIVISION OF
FINAL DESIGN 2
4
4/27/17
61556
KEYED NOTES:
1
FURNISH AND INSTALL 20A, 1P CIRCUIT BREAKER TO MATCH EXISTING PANEL.
MIN. INTERRUPTING RATING OF THE CIRCUIT BREAKER SHALL BE 10 KA.
1. SEE COVER SHEET FOR GENERAL NOTES, SYMBOLS AND
ABBREVIATIONS.
GENERAL NOTES:
LUMINAIRE SCHEDULE
FIXTURE
TYPE
MANUFACTURER/
SERIES
VOLT
SYSTEM
LED
LAMP MOUNTING DESCRIPTION
- - - - NO. WATTS - -
A
LITHONIA
"FEM LED" SERIES
(OR APPROVED EQUAL)
120/277
10000
LUMENS
4000K
1 80 W
SURFACE
MOUNT (ON BOTTOM OF
THE BEAM) & PENDANT
2' ENCLOSED & GASKETED
FIBERGLASS HOUSING WITH CLEAR
POLYCARBONATE LENS, 90CR1, WIDE
SPREAD LED FIXTURE NOMINAL
DIMENSIONS: 48 INCHES (LENGTH), 6
INCHES (WIDE), 4 INCHES (DEPTH)
B
LITHONIA
"DMW2" SERIES
(OR APPROVED EQUAL)
120/277
2000
LUMENS
4000K
1 19 W
AS SHOWN
ON PLAN
2' ENCLOSED & GASKETED
FIBERGLASS HOUSING WITH CLEAR
POLYCARBONATE LENS, 90CR1, WIDE
SPREAD LED FIXTURE NOMINAL
DIMENSIONS: 24 INCHES (LENGTH), 6
INCHES (WIDE), 4 INCHES (DEPTH)
C
LITHONIA
"TWPLED" SERIES"
(OR APPROVED EQUAL)
120/277
4,207
LUMENS
4000K
1 45 W WALL
WALL LUMINAIRE
WITH POLYCARBONATE COVER, 70 CRI,
TYPE 3 MEDIUM DIST. WITH BUTTON
PHOTOCELL NOMINAL DIMENSIONS: 16
INCHES (WIDTH), 15 INCHES (HEIGHT), 8
INCHES (DEPTH)
EM
LITHONIA "ELM2LED"
SERIES (OR APPROVED
EQUAL)
120/277 - 2 1.5W EACH WALL
EMERGENCY LIGHT, DUAL HEAD, WHITE,
6W NICKEL CAD. BATTERY, SELF
DIAGNOSTICS
EM1
LITHINIA "ELA QWP"
SERIES (OR APPROVED
EQUAL)
120/277 - 2 1.5W EACH WALL
REMOTE DUAL HEAD, EMERGENCY
LIGHTS, WEATHER PROOF
X1
LITHONIA "LHQM LED"
SERIES (OR APPROVED
EQUAL)
120/277 - 2 1.5W EACH WALL
SINGLE FACE, INDIRECT RED LED,
NICKLE CAD. BATTERY, WHITE FINISH,
SELF DIAGNOSTICS
1
E-03
PANEL SCHEDULE
SCALE: N.T.S.
1
1
3
E-03
LIGHTING FIXTURE MOUNTING DETAIL TO BEAM
SCALE: N.T.S.
4
E-03
LIGHTING FIXTURE MOUNTING DETAIL TO STEEL DECK
SCALE: N.T.S.
5
E-03
LIGHTING FIXTURE MOUNTING DETAIL TO WOOD PLATFORM
SCALE: N.T.S.
6
E-03
LIGHTING FIXTURE MOUNTING DETAIL TO FENCE
SCALE: N.T.S.
EXISTING BEAM
1/2"-13"x1 1/2" HEX
HEAD CAP SCREW
(TYPICAL)
P1386 BEAM CLAMP
(TYPICAL)
P1000 UNISTRUT
LIGHT FIXTURE
WOOD PLATFORM
LIGHT FIXTURE
WOOD SCREWS PHILLIPS
ROUND HEX ZINC PLATED
STEEL #12 1/14" LONG
(TYPICAL)
ROOFING
EXISTING CORRELATED
STEEL DECK (22 GA. MIN)
THICK STEEL
P1000 UNISTRUT
LIGHT FIXTURE
SELF TAPPING SCREW
#12x1 1/4" LONG ZINC
PLATED SLOTTED HEX
WASHER HEAD SCREWS.
(TYPICAL)
FENCE
BACKER PLATE
(COVER PLATE)
1/4" Ø THRU - BOLTS
1/4" Ø BOLT x 1" LONG
W/NUTS & WASHER ZINC
PLATED (TYPICAL)
LIGHT FIXTURE
7
E-03
EXIT SIGN/EMERGENCY LIGHT MOUNTING DETAIL TO WALL
SCALE: N.T.S.
HDI-P DROP-IN ANCHOR
3/8" Ø x 3/4" LONG (TYPICAL)
EXISTING CMU
WALL
EXIT SIGN OR
EMERGENCY LIGHT
P3016-1420 1/4" CHANNEL NUT W/O
SPRING W/ 1/4" DIA. x 3/4" LONG
BOLT & 1/4" DIA. WASHER (TYPICAL)
P3016-1420 1/4" CHANNEL NUT W/O
SPRING W/ 1/4" DIA. x 3/4" LONG
BOLT & 1/4" DIA. WASHER (TYPICAL)