MU-G15Three - Phase Submersible Pump Controllers
U 5M -G1
Technical Details for MU-G15 Star Delta Controller Ordering Details for MU-G15 Star Delta Controller
Features and Applications ofMU-G15 Submersible Pump Controller
MU-G15
n
n
n
n
n
n
Protection from Single – PhasingProtection from Overload ConditionsProtection from Phase ReversalProtection from Phase Unbalance 55 V (+/-5 V)Proven & tested MK1 ContactorWideband coil operates from 65% to 110% of rated coil voltage (e.g. 360 V Coil operated from 234 V to 396 V)
n
n
n
n
n
n
Indication of healthy supply indicationAuto Restart (with 30 sec ON Delay)Power ON & Pump ON indicationUnique Dual Volt-Ammeter & AmmeterEasy replacement of sparesTerminal block for easy termination
Features:
MU-G15 Star-Delta - 7.5 HP to 15 HP n
n
Borewell submersible water pumpOpen well submersible water pump
Range Typical Applications :
6 - 10
9 - 14
CS94091POVO
CS94091POAO
Pump Ratingat 415 V, 3Ø, 50 Hz
WithRelay range
(A)
Std.Pkg.
(Nos.)
Catalogue No.
Type
HP kW
Coil Voltage360 V
Coil Voltage400/440 V
1
1
10
15
7.5
11
CS94091COVO
CS94091COAO
MU-G15
Star-Delta
Rating
Contactor
Overload Relay
Coil Voltage
Pick-up Voltage
Drop-off Voltage
Rated Insulation Voltage
Rated Operational Voltage
Service Temperature
Conformity to Standard
Degree of Protection
No. of full Start
Back-up Operation
Measurement Offered
Indicating Lamps
7.5 HP to 15 HP
MK1
MK1
360 V, 415 V
65% to 110% Uc
25% to 35% Uc
Ammeter
Voltmeter (with selector switch)
Supply ON (3-Phase)
Pump ON
690 V
415 V AC0-5 C to 55 C
IS/IEC60947-4-1
IP54
30 operations per hour
Type 2 with HF Fuses
0
16 Sq.mm. with Lug
(Lugs provided inside
MU-G Controller)Terminal Capacity
Overall Dimensions MU-G15
Note: All Dimensions are in mm
40
8
400
350
8
4 Mounting HolesSuitable for M8
MU-G15
M -U G15
147
40
0
35
0
118.83.5