Optek Advanced Concrete Systems
CCOOMMPPANYANY BBRIRIEEFF
OptimumOptimum AAuusstraliatralia - has been successfully manufacturing specialized Products including concrete
curing compounds and coatings for the civil and commercial construction industry for more than 10 years.
Optimum Australia was the FIRST Company in Australia to introduce Hydrocarbon Resin curing
compounds to major civil projects.
During the past 7 years Optimum Australia have strived to formulate products that are safe to use,
environmentally friendly and consistently still performs above the requirements set out by Standards and its
customers. Some of these products currently being used today include XDS, Optek BCP, Optek AC and
Optekl NS1. These Products still have no equivalents available in the Industry.
Over the past 4 years Optimum Australia have undertaken an extensive research program to develop and
manufacture unique concrete enhancement and repair materials as a result of a comprehensive market
investigation, research and development, lengthy testing and trials.
Primarily the Company’s goal was to establish and develop products that were Environmentally and User
Friendly, Exhibit High Performance in harsh working environments and above all be 100% compatible with
Concrete. The entire curing and concrete enhancement/repair ranges will be produced in the Canary Islands
for European, Middle Eastern and African markets and in India for the Asian region from 2004.
OPTEKOPTEK™™OPTEK™OPTEK™ PPRRODUODUCCTTSS AARERE TTOOTTAALLLLYY CHCHLLORORIIDEDE FRFREEEE..
With new Environmentally Friendly Technology we have forged new industry alliances and with our
research facilities and testing laboratories we now offer our clients Technical Expertise and Custom Blended
materials for any project requirements.
We hope the management of Optimum Australia can be of Assistance to you in the near Future.
NOTE: Products are Custom made to specific climatic requirements and cement types used.
stanimex
OPTEKOPTEK™™HHCONCRETE ENHANCER
Australian Standard ISO 9000
1
USES
DESCRIPTION
OPTEK H is a blend of Nitrates and Nitrites blended in aqueous solution.The OPTEKTM H Liquid is designed to penetrate the concrete and chemically activate available unhydrated cement. This reaction has the benefit of bonding the existing concretetogether whilst reducing the pore size and actively promoting new cement growth in shrinkage cracks.
OPTEKOPTEK™™ LL ISIS TOTALTOTALLLYY CHCHLLORIDEORIDE FFREREEE..
ADVANTAGES
• Can be applied on a damp or dry surface.• Concrete will retain a natural appearance.• Does not contain solvents or polymers• Concrete can be put into service immediately after application• Can be applied regardless of temperature.
• Dust proofing of factory floors, car parks etc• Reinstatement of poorly finished concrete• Assists in curing concrete.• Waterproofing of roof decks, balconies etc.• Enhancing under developed features of concrete.
BENEFITS
• W ill p r o tect the rebar from corrosion• Minimal preparation of the concrete to be treated• W ill reduce the pore size of the existing concrete.• W ill p r o m ote further hydration of existing cement• Has the ability to promote “new growth” in shrinkage cracks
2
OPTEKOPTEK™™HHCONCRETE ENHANCER
Australian Standard ISO 9000
PREPARATION
1. The surface to be treated should be cleaned and free from any type of coatings. (epoxy, paint etc).Any loose, flaking or spalling concrete must also be removed. A pressure wash at this time is advisable.
2. To open the pores of the concrete and allow adhesion it is required that an acid wash is done.A general acid wash contains 20lts of water to 1lt of hydrochloric acid. It must be remembered to add t h e acid to the water not the other way around.
3. Using the correct clothing and equipment apply the acid solution to the concretesurface to be treated. Allow the acid to ‘work’ on the concrete for 5-15mins. After this time pressure wash the concrete surface.
APPLICATION METHOD
OPTEK H is a ready to use product and should not be watered down.
OPTEK H can be applied by mop, broom, brush, or spray to the area to be treated at a rate of one litre per 3-5 square metres.
Allow 4-6 hours then apply a second coat.
Do not allow OPTEK Hto form a coating on the surface of concrete.
For OPTEK Hto work successfully it must penetrate the concrete surface.
The treated concrete surface can be put back into service immediately after the final application of OPTEKTM H
All tools and/or equipment used in this operation should be cleaned with water
CRCRIITICTICAALL PPOINOINTTSS OONN TTHHEE AAPPPLPLIICATCATIIOONN OOFF OPTEKOPTEKTM HHa. The concrete to be coated must be free of silanes, siloxanes,
impregnation treatments and coatings.b. Always use the correct safety clothing and equipment. c. Ready to use Product - DO NOT ADD WATER.d. Do not allow a coating to be formed.e. Ensure OPTEK Hpenetrates the concrete.
3
OPTEKOPTEK™™HHCONCRETE ENHANCER
Australian Standard ISO 9000
TYPICAL DATA
• Name OPTEKTM H
• Use Concrete enhancer
• Odour None
• Mix Ratio N/A
• Specific Gravity 1.01
• Ph range 10
• Min application temp. -5°C
• Max application temp. 40°C
• Dry Time 4 Hours @ 2 0 °C
• Packaging 205 Lt drum, 20 Lt drum
• UN NUMBER N/A
• HAZCHEM CODE N/A
• Packaging Group N/A
• Poison Schedule N/A
• Dangerous Goods Class N/A
OPTEK™OPTEK™ LL ISIS TTOOTALLYTALLY CCHHLORIDELORIDE FREEFREE..
REFER TO MATERIAL SAFETY DATA SHEET FOR PRECAUTIONS AND PERSONAL PROTECTION Disclaimer: Any Advice, Recommendation, Information, Assistance or Service provided by Optimum Australia in relation
to goods manufactured or supplied by them or their Use and Application are in Good Faith and is believed by Optimum Australia to be appropriate and reliable. However, any Advice, Recommendation, Information, Assistance or Service
provided by Optimum Australia is provided without Liability or responsibility. The manufacturer reserves the right to make alterations to OPTEK without notice.
COMPANY DETAIL
4
OPTEKOPTEK™™HHCONCRETE ENHANCER
Australian Standard ISO 9000
MATERIAL SAFETY DATA SHEETS
Name: Optimum Australia,Address: 12 Frankston Gardens Dve., CARRUM DOWNS. Vic 3201, AUSTRALIAPhone: 61 3 9782 3233 Business Hours,Fax: 61 3 9782 3244Mob: 61 417 346 280
IDENTIFICATION
Product Name: OPTEKTM L UN Number: Not RegulatedShipping Name: OPTEKTM L Dangerous Goods Class: Not RegulatedSubsidiary Risk:Poisons Schedule:
Not Regulated5
Hazchem Code:Packaging Group:
Not RegulatedNot Regulated
Chemical Description: Proprietary formulation of calcium hydronatrium aluminate.
Use: Hardener and waterproofer of concrete.
PHYSICAL DESCRIPTION / PROPERTIES
Appearance: Opaque colourless liquid Flammability Limit (%): N/A Odour: Alkaline Specific Gravity: N/A Solubility in water (g/l): Complete Inorganic solvents: N/A Boiling Point: 102°C approx Vapour Pressure @25°C NAS pH: 12 Relative Density: N/ASolids (%): N/A Shelf Life: 3 monthsFlash Point (°C): N/A (Non-flammable) Other properties: NAS
INGREDIENTS
- 9% ÷ 12.5% of chemical concentrate- 60% ÷ 90% WaterHEALTH HAZARD INFORMATION
EMERGENCY AND FIRST AID PROCEDURES
HEALTH EFFECTSExpect similar reaction as to mild or strong alkali. Not known to be a carcinogen, mutagen or teratogen.Swallowed: Corrosive and irritant. May cause caustic burns. Eye: Corrosive and irritant. May cause caustic burns. Skin: Corrosive and irritant. May cause caustic burns. Inhaled: Corrosive and irritant. May cause caustic burns.
5
OPTEKOPTEK™™HHCONCRETE ENHANCER
Australian Standard ISO 9000
First Aid Facility: Ensure availability of clean water for eye/skin wash.Advice to Doctor: Treat symptomatically.
FIRST AIDSwallowed Do not induce vomiting. Give water in large amounts plus 20-25mls of vinegar in
water. Seek medical attention. Never cause an unconscious person to eat, drink or vomit.
Eye: Treat all contact promptly to minimise permanent damage to eyes or tissue.Skin: Remove contaminated clothing. Wash before re-use. Washed contacted area
well with soap and water.Inhaled: Remove to clean air. Seek medical aid if breathing problems arise.
PRECAUTIONS FOR USE Exposure Standards: See “Manual” Engineering Controls:Ventilation: Use natural ventilation and/or suitable equipment to maintain below
TLV. Fully observe Australian Standard AS 2865 procedures when entering confined spaces such as storage or transport tanks.
Personal Protection: Gloves Long Impervious: YES Overalls: YES Eye Protection: YES
Flammability: Non-combustible.
SAFE HANDLING INFORMATIONStorage and Transport: Avoid heat, flames, and oxidising agents.Spills: Note: Spills may make floor surface slippery. Bund or otherwise contain
spills, in particular, prevent ingress of spillage to storm water drains. Collect spillage in drums then collect residue by applying absorbent material to spill area.Sweep/mop up first: YES Wash down with detergent/water: YES Absorb in dry inert material: YES
Disposal: Observe all Federal, State and Local regulations.Dispose of all waste materials at an approved disposal site. Landfill: YES
Fire/Explosion Hazard: Explosion Limit - upper : lower NASDust explosion hazard: N/A Hazardous decomposition products: NAS Hazardous polymerisation products / reaction: Unlikely Extinguishing media: NAS
Fire fighters should wear self-contained breathing apparatus in enclosed areas.
All information contained in this Data Sheet is as accurate and up to date as possible. No warranty expressed or implied is made as to its accuracy, reliability or completeness.
6
OPTEKOPTEK™™HHCONCRETE ENHANCER
Australian Standard ISO 9000
Concrete Curing & surface strengthening – Roof top Car Park
7
OPTEKOPTEK™™HHCONCRETE ENHANCER
Australian Standard ISO 9000
Spillway repair
OPTIMUMOPTIMUM AUSTAUSTRRALIAALIA PPTTYY LLTTDD
Mr.Mr. Sabri IbrahimSabri Ibrahim
3 1/3 Mallory Court
BAYSWATER. Vic 3153 AUSTRALIA
Tel: 61 3 9761 5955 (Business Hours), Mob: 0432 178 934
Fax: 61 3 9761 7535