Metro Trains Melbourne Engineering Approved Product List As of 20/01/2020 (Updated monthly)
TA
NumberIssue Title/Product Function/Application(s)
Applicable
System(s)SME Approval Type Approval Status
Approval/Rejected
DateExpiry
Withdrawal/Suspension
DateType/Model Number
Hardware
Revision No.
Software Version
No.Manufacturer Place of Manufacture Condition and Service Restrictions
00835 1 WESTRACE 110 Vac and 50 Vdc Surge arresters and basesSurge Arresters and bases for use 110 Vac for WESTRACE LOM circuits and 50 Vdc for PIM inputs and ROM outputs. Siemens recommend
use of these arresters on all inputs and outputs that extend from the location case of SER.Signals TBC Registered
110 Vac Arrester 2178081-1
110Vac Base 2198030-2
50 Vdc Arrester 2178047-1
50 Vdc Base 2178030-1
C NA Siemens Various
00834 1 Robust Multifunctional Router
The Garderos R-7700 series routers are specifically manufactured for use in remote, difficult accessible locations with harsh environmental
parameters. Due to the many uplink variants, the R-7700 series can be used in a lot of different applications such as secure and reliable
connectivity for professional industrial applications in telecommunications, energy supply and traffic surveillance.
OCS TBC Engineering Product Approval In ProgressR-7700 Series (R – 7758, 7728,
7707)GWUZ 3.5.26 Garderos Germany
00833 1 Frauscher Remote Monitoring DisplayRemote Monitoring display is an additionally software which is used to interface to existing Frauscher Diagnostic units (FDS) databases to
provide live monitoring, warnings & errors and higher-level overview of the existing Frauscher axle counter systems installed in MTM’s network.OCS Wayne Purton Engineering Product Approval In Progress RMD Development NA 1 (DEV)
Frauscher Sensor
TechnologyAustria
00832Golden Phoenix Suspension Insulator with Iron Clevis &
Tongue 10231A
Golden Phoenix insulator mentioned below will be used as a direct replacement of two glass or porcelain disc insulators for suspending the
catenary wire as the proposed insulator has a similar overall length of two disc insulators (295mm). Currently, a K-Line insulator product number
KL15SCTF is used as a direct replacement for two glass or porcelain disc insulators. It also has a similar overall length (292mm).
Overhead Karim Kobrosly Full Type Approval In Progress 10231A NA NA
Zhejiang Golden Phoenix
Electric Power Technology
Co, Ltd.
China
00831 1 GVK / Raychem PTC-TK100-IEPMedium voltage screened separable connectors designed to connect single and three core polymeric cables to medium-voltage gas insulated
switchgear and other equipment that utilises CENELEC bushings type “C” specified for 630/1250A up to 24kV.Substations Craig Tooke Full Type Approval In Progress PTC-TK100-IEP NA NA GV Kinsman Germany
00830 1 Quad-Head HDMI KVM Smart AVI UHDN-4P Switch
4-port, quad-head HDMI KVM switch with Ultra-HD 4K/60Hz resolution video emulation. It can control keyboard-mouse functions on up to four
remote computers, and emulates video from HDMI source devices.
Application- this device will be used at the Caulfield Signal box to switch between the 2x signal controller workstations.
OCS Wayne Purton Engineering Product Approval Approved 9/12/2019 UHDN-4P-QUAD NA NA SMART AVI USA
00829 1 Extreme X590 Series Switch and ModulesThe Extreme X590 Series is a Core Layer Switch. The X590 Series can provide both Layer 2 and Layer 3 (switching/routing) functionality. The
switch can have 24 ports Ethernet or SFP, a QSFP+ and 2 QSFP28 (up to 100Gb). OCS Damien Watson Engineering Product Approval Registered
X590 -24x-1q-2c
X590 -24t -1q-2cNA NA Extreme Networks China
00828 1TMC 10kVA 230/110V Li0 SINGLE PHASE PHASE AN IP22
DRY TYPE TRANSFORMERTo convert from 230V to 110V at rating of 10kVA, to be used for signalling within a railway network.
Electrical
NetworksCraig Tooke Full Type Approval Approved 13/12/2019 TMT150100230A-DD-IP22 NA NA
Transformers Manufacturing
Company PTY LTD (TMC)Australia
00827 1 STRAIL TGSI Tactile Tactile indicators for pedestrian crossings Track Zoe Cheng Grandfather Rights Approved pedeSTRAIL Rubber Panel NA NA STRAIL Germany
00826 1 Vossloh Sleep Anchor (Lateral restraint)Vossloh sleeper anchors are used for the efficient improvement of lateral resistance strength
on ballasted track for various applications including conventional rail and urban transport.Track Hassan Elaina Full Type Approval Rejected VOS-SA-SN/V NA NA
VOSSLOH FASTENING
SYSTEMSAustralia
00825 1 X465 Series switch and modules
The Extreme x465 is a new release and upgrade from the currently used X460 switches.
The units have 24-48 Ethernet ports of 100Mb/1/2.5/5Gb ports with 802.3bt Type 3 POW (60 W), 2 fan modules, and 2 unpopulated PSU slots.
All unit have 2 X front facing stacking ports, Versatile Interface Module (VIM) slot that allows for modular additions of SFP ports (SFP+, SFP28,
QSFP). This allows the unit to be customised to suit per site.
OCS Damien Watson Engineering Product Approval In Progress
X465-48T
X465-48P
X465-48W
X465-24MU
03Extreme XOS 21.1 or
higher Extreme Networks China
00824 1 LAI Switchgear 12kVEssential services power distribution switchgear 2.2/3.3kV ESDS Multi Panel arrangement.
For Essential services or Signal power purposes.
Electrical
NetworksZahra Bayat Full Type Approval Approved 19/12/2019 Metro ESDS NA NA Lai Switchboards Australia
00823 1 LAI 650V Switchboard 1000V signalling switchboard to provides signal power of 650V to the existing signallling equipment.Electrical
NetworksTBC Full Type Approval Registered 30449 NA NA LAI Switchboards Australia Australia
00822 1 TMC 60kVA 3300/400V Step-Down Transformer
60kVA 3300/400V Dyn11 AN IP22 3 PHASE DRY TYPE TRANSFORMER.
To convert from 3300V to 400V at rating of 60kVA, to be used for signalling within a railway network.
To be used in cabled indoor applications, as part of the ESDS system, where 400V power is required to be derived from a 3.3 kV supply up to a
Electrical
NetworksCraig Tooke Full Type Approval Approved 16/12/2019 DRY TYPE TRANSFORMER NA NA TMC Australia
00821 1TMC 180kVA 400/3300V Step-Up Transformer (YNd1 AN
IP22 Dry Type Transformer)A 400V/3300V Step-up transformer fed by UPS or main switchboard at 400V (to suit the 3300V signalling supply).
Electrical
NetworksCraig Tooke Full Type Approval Approved 5/12/2019 31922 NA NA TMC Australia
00820 1TMC 180kVA 400/650V Step-Up Transformer (YNd1 AN
IP22 Dry Type Transformer)A 400V/650V Step-up transformer fed by UPS or main switchboard at 400V (to suit the 650V signalling supply).
Electrical
NetworksCraig Tooke Full Type Approval Approved 1/11/2019 31921 NA NA TMC Australia
00819 1
Wago 4-Conductor carrier terminal block; for DIN-rail 35 x 15
and 35 x 7.5; 2.5 mm2 (Incl. Wago Pluggable Bridging
Module)
Two products are proposed to be type approved as part of this application and is relevant to the changeover module that has been submitted as
part of a separate type approval application for the Wago (Dold) Relay Assembly (module).
The two products are the 4-conductor terminal block and the pluggable bridging module from Wago.
Signals Gail Smith Full Type Approval In Progress
280-606 Terminal Block
19-0149A – Pluggable Bridging
ModuleNA NA Wago Germany
00818 1 Cubis MM RAILduct Low Profile GLT
The MM Trough is a lightweight glass-reinforced plastic moulded cable trough system which weighs led than 10kg but can take pedestrian and
vehicle loads. The troughing comes in 1 metre long sections and is suitable for single person lift and install, is fire retardant and provides tamper
proof locks and keys.
Signals TBC Full Type Approval In Progress 611001 NA NA Cubis Systems UK
00817 1Weight Wheel Wire Rope (manufactured by Casar) and
Wire Rope Pulley (manufactured by Elektroline)Weight Wheel Wire Rope is used in conjunction with the Wire Rope Pulley as part of the overhead wiring weight wheel assembly. Overhead TBC Full Type Approval In Progress
Bezinal coated 8mm Paraplast &
251331NA NA Casar Germany/Czech Republic
00816 1 Raychem Termination Kit PTC-TK35-IE1C
• Termination Kit based on using the TE Raychem RSTI-5851
• Raychem RSTI-58 screened separable connectors are designed to connect single- and three-core polymeric cables to medium-voltage gas
insulated switchgear and other equipment using CENELEC bushings type “C” specified for 630/1250 A up to 24 kV.
• The complete kit includes lugs and facilitates installation and storage.
Substations Craig Tooke Engineering Product Approval Approved 25/11/2019 PTC-TK35-IE1C NA NA Raychem Germany
00815 1 Tensar TriAx TX190L Geogrid
The tensar geogrid is a high density punched polypropylene sheet approximately 2-3mm thick. The product and its application require
geotechnical engineering evaluation to confirm the required stiffness performance when using in conjunction with a layer of granular engineered
fill.
Track Gordon Djurdjevic Full Type Approval Approved 14/10/2019 TX190L NA NA Tensar UK
00814 1 K-Line 15kV Suspension Insulator with Iron Clevis & Tongue
The K-Line insulator mentioned below will be used as a direct replacement of two glass or porcelain disc insulators for suspending the catenary
wire as the K-Line insulator has a similar overall length of two disc insulators (297mm). Currently, a Henley insulator product number 56145-36
is used as a direct replacement for two glass or porcelain disc insulators. It also has a similar overall length (294mm) to the proposed K-Line
Insulator
Overhead Karim Kobrosly Full Type Approval Approved 3/10/2019 KL15SCTF NA NA K-Line Insulators Limited Canada
00813 1 DPI Hotmelt Thermo PlasticDPI Hotmelt Thermo Plastic is an integrated In-situ application design to improve the safety level of pedestrian traffic utilising the platforms at
flinders St Railway Station. This product meets Australian standard AS4049.2
Structures &
FacilitiesJoe Cavric Full Type Approval Approved 16/12/2019 NA NA NA DPI Australia Australia
00812 1 Axis Q8742-E CameraAXIS Q8742-E Bispectral PTZ Network Camera is a high-end combination of thermal camera with outstanding contrast for reliable detection and
verification around-the-clock and in all weather and light conditions and an exceptionally light-sensitive visual camera for identification purposes.OCS Damien Watson Engineering Product Approval Approved 6/08/2019 Q8742-E NA NA Axis Sweden
00811 1 Axis P3905-R MK II Dome Camera
AXIS P3905-R MK II Mk II Network Camera is a compact, rugged camera specially designed for video surveillance in vehicles and rolling stock
providing HDTV 1080p video. The camera provides HDTV 1080p with WDR and Lightfinder to ensure high image quality in mixed and low-light
conditions.
OCS Damien Watson Engineering Product Approval Approved 5/08/2019 P3905-R MK II Dome Camera NA NA Axis Sweden
00810 1 Axis P3225-VE Dome Camera
AXIS P3225-VE Mk II Network Camera is an outdoor-ready fixed dome providing HDTV 1080p video. The camera features a varifocal lens for
remote focus and zoom, P-Iris control for optimal clarity and depth of field, and day/night functionality. Equipped with WDR to handle scenes
with strong light variations, and Lightfinder technology for exceptional light sensitivity, this camera provides outstanding video quality in both
strong and poor light conditions.
OCS Damien Watson Engineering Product Approval Approved 5/08/2019 P3225-VE Dome Camera NA NA Axis Sweden
00809 1 Axis F1005-E Sensor UnitAXIS F1005-E Sensor Unit is a discreet camera used with the Axis F44 4-Channel Main Unit. The sensor unit is a 1080p camera that can be
flush mounted in a wall or ceiling and provides a 113o field of view.OCS Vincent Scotto Engineering Product Approval Approved 28/10/2019 F1005-E Sensor Unit NA NA Axis Sweden
00808 1 Model 2019 – Heavy Duty Transition Coupler
The transition coupler is designed to be connected to an AAR S-106 10A type coupler on one end and to a Scharfenberg Type 10 Multifunctional
Coupler on the other end. This new heavy duty transition coupler is designed to Working Load Limit (WLL) of 300 kN. The design principle is the
same with the legacy coupler that’s already proven reliable
Rolling Stock Adam Anderson Full Type Approval Approved 13/12/2019 UGL 15-A05 NA NA UGL 15-A05 Australia
00807 1 X’Trapolis Heavy Duty Transition CouplerThe Model 2002 heavy duty transition coupler is compatible for connection on one end to a AAR S-106 10A wagon coupler and on the other end
to a Scharfenberg Type 10 Multifunctional CouplerRolling Stock Adam Anderson Full Type Approval Approved 10/09/2019 10/03/2020
Heavy Duty Transition Coupler
Model 2002NA NA Built during PTC era Unknown
00806 1 1500 V DC 240 mm2 1C Outdoor termination kit1500 V DC 240 mm2 copper outdoor termination kit with 400 mm tail with cable lug. To be used with 1 core 240 sq. mm
screened Cu cable.Substations Craig Tooke Full Type Approval Approved 5/07/2019 NA NA NA Raychem Germany
00805 1 Single Core 240 mm2 copper conductor 3.8/6.6 kV
Cu/XLPE/CWS/PVC/HDPE
Single Core
Conductor: Stranded compacted copper
Conductor Screen: Semi-conductive conductor screen - 0.3 mm minimum wall thickness
Insulation: 3.8/6.6 kV TR-XLPE – 2.6 mm nominal wall thickness
Substations Craig Tooke Full Type Approval Approved 5/07/2019 NA NA NA Prysmian Australia
00804 1 Lighthouse Energy Solar StationThe lighthouse energy solar station is a rugged, all terrain, and all weather, independent solar & hybrid capable power station delivering
dependable, reliable power all year round, year after year.
Structures &
FacilitiesJoe Cavric Full Type Approval Approved 16/12/2019
00803 1 Hofmann Lightweight Wheelchair Ramp Lightweight wheelchair ramp of carbon fibre construction. Approx. 7kg. Ramp designed and tested in accordance with AS/NZS 3856.1:1998.
Rated Safe Working Load: 300 kgRolling Stock Mohamed Awadalla Full Type Approval In Progress EST102542390 NA NA Lockelec Innovation Australia
00802 1 Axis F4005-E Sensor UnitAXIS F4005-E Sensor Unit is a vandal resistant discreet dome camera used with the Axis F44 4-Channel Main Unit. The sensor unit is a 1080p
camera that can be recess mounted and provides a 110o field of view. OCS Vincent Scotto Engineering Product Approval Approved 28/10/2019 F4005-E Sensor Unit NA NA Axis Sweden
00801 1 Axis F44 Dual Audio Input Main Unit
AXIS F44 Main Unit supports up to four AXIS F Sensor Units for surveillance of four closely situated areas, allowing simultaneous streaming of
views from four different areas through one Ethernet port using POE. Each sensor unit has an Individually configurable stream up to
1080p/25fps.
OCS Vincent Scotto Engineering Product Approval Approved 28/10/2019 F44 Dual Audio Input Main Unit NA NA Axis Sweden
00800 1 Advantech MIC-7700 Industrial PCCompact and Fanless Industrial PC. For use with CCTV Surveillance Trailer. Current industrial PC’s such as Neousys and FitPC do not have
the required storage or video capabilities for the CCTV Trailer and cannot be used.OCS Vincent Scotto Engineering Product Approval Approved 28/10/2019
00799 1 Axis C3003-E Horn SpeakerAXIS C3003-E Network Horn Speaker is an outdoor loudspeaker that provides clear, long-range speech for remote speaking in live video
surveillance.OCS Vincent Scotto Engineering Product Approval In Progress C3003-E NA NA Axis Sweden
00798 1 Tread Safety Grip – Base and HardenerTread Safety Grip is an integrated In-situ application designed to improve the Safety level of pedestrian traffic on wet or dry Escalator and
Travellator tread plates.
Structures &
FacilitiesJoe Cavric Full Type Approval In Progress 16/09/2019 NA NA NA Escalator Safety Factory Australia
00797 1150kVA 400/650V YNd1 AN IP22 DRY TYPE
TRANSFORMER (step-up transformer)400V/3.3kV step-up transformer is fed by the UPS or main switchboard which is at 400V.
Electrical
NetworksCraig Tooke Full Type Approval Approved 2/07/2019
Serial Number: 31859-01
TMC Part Number: NILNA NA TMC Australia
00796 1150kVA 400/3300V AN IP22 CAST RESIN TRANSFORMER
(step-up transformer)400V/650V step-up transformer is fed by the UPS or main switchboard which is at 400V.
Electrical
NetworksCraig Tooke Full Type Approval Approved 2/07/2019
Serial Number: 31860-01
TMC Part Number:
TMT111503300-IP22-YNd1
NA NA TMC Australia
00795 1Edilon Sedra Corkelast Embedded Block System RetroFit
(EBS-RF)
EBS-RF is designed to replace worn out booted monolithic blocks and/or bi-block sleepers embedded in concrete when these systems will have
reached the end of their economic life.Track Gordon Djurdjevic Provisional Type Approval Approved 15/10/2019 15/10/2020 EBS-RF NA NA Edilon Sedra Netherlands
Please refer to L1-CHE-PRO-004 for T.A Procedure
Uncontrolled if printed. Controlled by MTM Eng. Systems (OCE)
Page 1 of 22 [email protected]
Metro Trains Melbourne Engineering Approved Product List As of 20/01/2020 (Updated monthly)
TA
NumberIssue Title/Product Function/Application(s)
Applicable
System(s)SME Approval Type Approval Status
Approval/Rejected
DateExpiry
Withdrawal/Suspension
DateType/Model Number
Hardware
Revision No.
Software Version
No.Manufacturer Place of Manufacture Condition and Service Restrictions
00794 1 Vertiv LSF42/CR025 The Vertiv LSF42/CR025 is an in-row cooler (LSF42) and associated condenser (CR025) that provides energy efficient, rack-level cooling. OCS Joe Cavric Full Type Approval In Progress LSF42/CR025 NA NA Vertiv Co Various
00793 1 Selectequip IRJ Head Repair Kit
The IRJ Head Repair Kit allows an in-situ repair to damaged end posts in Insulated Rail Joints (IRJ’s). The process involves cutting through the
original insulated gap using a rotary cutting tool and filling the gap with a fast-curing two-part polyurethane resin. This hardens to provide
electrical insulation and a robust repair.
Track Nathan Baker Full Type Approval Approved 25/10/2019 09-405 NA NA Selectequip Ltd UK
00792 1 Gauge Tie Bar A non-invasive, insulated tie bar designed to retain and maintain the track gauge where fastenings or bearers are worn Track Hassan Elaina Full Type Approval In Progress 0057/048833 NA NA Unipart Rail UK
00791 1 Huck 360® Huck 360® is a high vibration & fatigue resistant nut & bolt fastening system that allows for fast, free spinning nut installation. Track Hassan Elaina Full Type Approval In Progress 1inch NA NAArconic Fastening Systems
AustraliaUSA
00790 1 Wagner Covertop Mesh/ TredDeckThe Covertop mesh and TredDeck is manufactured from FRP (Fibre reinforced Polymer) material. The product is intended to be used as an
alternative to traditional steel/concrete and timber formed decking arrangements. Track John Dauth Full Type Approval Approved 3/12/2019 DGS-VCOV & CT NA NA Wagner Australia
00789 1 Computar 9-50mm camera lens An intelligent 9-50mm camera lens with remote focus and zoom capability for use with the FLIR CF-6308 fixed camera models. OCS Mark Cole Engineering Product Approval In Progress EG6Z0915TCS-MPWIR NA v5.1.0 or higher Computar Japan
00788 1 Computar 3.9-10mm camera lens An intelligent 3.9-10mm camera lens with remote focus and zoom capability for use with the FLIR CF-6308 fixed camera models. OCS Mark Cole Engineering Product Approval In Progress EG3Z3915TCS-MPWIR NA v5.1.0 or higher Computar Japan
00787 1 Westermo RedFox Industrial Rack (RFIR)The RedFox Industrial Rack (RFIR) family are a set of layer 2 and layer 3 industrial ethernet switches that come with a variety of port
configurations.OCS Wayne Purton Engineering Product Approval Approved 22/07/2019
RFIR-228-F4G-T7G-DC/RedFox-
5528-E-F16G-T12G-LVNA v5.1.0 or higher Westermo Sweden
00786 1 Vortok ESR/TSR Equipment
A display system for warning/information signage for train drivers, which is erected by clamping to the rail foot. Being lightweight, it does not
require any heavy or ballasted base and by clamping to the rail foot does not require ground investigation or scanning for buried cables or
services.
Track Nathan Baker Engineering Product Approval Approved 5/08/2019 NA NA NA Vortok International UK
00785 1 Crydom DRACN Relay6.2mm Din-Rail Mount SSR Assembly fitted with replaceable solid-state relay and integrated LED.
Input voltage range 3-12Vdc, Output switched range 0-48Vdc @ 100mAOCS Vincent Scotto Engineering Product Approval Approved 18/04/2019 DRA-CN048D05 NA NA Crydom Mexico
00784 1 100mm2 Forked Collar Socket A forked collar socket is used to terminate bare aerial overhead conductors. A forked collar socket consists of two main parts, the body
(stainless steel) and the collet (bronze composition). Overhead Izy Perona Full Type Approval Approved 7/10/2019 610.045.000 NA NA Arthur Flury Switzerland
00783 1 Top Mounted Platform Filler (TMPGF) Platform Gap Filler is used for closing the gap between the platform coping and train. Track Hassan Elaina Full Type Approval Approved 24/05/201970mm x 1000mm EDPM Series 2
Top Mount PGFNA NA Austact Civil Australia
00782 1 3M™ Anti-Graffiti Wrap Gloss OverlaminateThe 8588G is a conformable anti-graffiti over laminate. The nature of Anti-Graffiti films (such as 8993 currently used on the side livery) has
always been that it is not conformable, but is highly resistant to chemicals and stains. Rolling Stock Adam Anderson Full Type Approval Approved 13/06/2019 8588G NA NA 3M Japan
00781 1 Eaton 650V Switchgear
The Xiria E 650V Switchgear provides switching capability as a backup supply for the existing 650V signal power between Kananook and
Frankston substation.
For Substation Installation
Electrical
NetworksZahra Bayat Full Type Approval Approved 17/07/2019 Xiria E RA-S05 CP1YY01S Eaton Netherlands
TA withdrawn as per email on 12/04/2018, MTM Electrical Engineering suggested that Eaton E-
Type is similar to the Type approved Xiria Switchgear.
Carmel Elliott from SPA advised to re-activate the type approval on 05/07/2019 (verbally) and
00780 1 AEG UPS System
This product is required for special circumstance in Kananook and Carrum substations where the UPS is supplying two different signal systems
with two different voltages. The main signalling voltage is 3.3kV which is already a type approved unit. This UPS has a second 650V output for
backups to the existing 650V signalling system which won’t be upgraded in current SPA project.
Electrical
NetworksZahra Bayat Full Type Approval Withdrawn 23/05/2019 Protect 4.33 220-400-384-400 RA-S05 CP1YY01S AEG Power Solutions Germany
TA withdrawn as per email on 23/05/2018, MTM Electrical Engineering suggested it's similar to
AEG UPS unit (TA00150) - already type approved
00779 1 Neutral Earthing Resistor (NER)The NER (Neutral Earthing Resistor) helps to reduce fault current in case of any fault on the network. This helps to reduce the earth grid size
and less fault level on the equipment and network. It is required in the MTM standards engineering which states that an NER must be installed.
Electrical
NetworksCraig Tooke Full Type Approval Approved 6/06/2019 CT-NER-3.3kV 85A 3sec NA NA Capacitor Technologies Australia
00778 1 TMC 500kVA ESS Transformer To convert from 22000V to 400V at rating of 500kVA, to be used for auxiliary or essential services within a railway substation. Electrical
NetworksCraig Tooke Full Type Approval Approved 4/07/2019 TMT0550022-BD-IP43-Dyn1 NA NA TMC Australia
00777 1 ABLOY PLLW321T/20 CLIQ Protec2 PLLW321. Padlock 20mm Vert, 19mm H clearance OCS Mark Cole Grandfather Rights Approved 8/02/2019 PLLW321T/20 NA NA ASSA ABLOY Sweden
00776 1 VRC GRP Cable Management System
VRC GRP Cable Management System, is a light weight Cable Management System. Modular in design, can be installed in various
configurations, and multiple Vertical Stacks, as per the drawings attached. Load tested for a singular module to 1000kg + Over a non-supported
2mtr span, Load capacity will increase if stacked.
Electrical
NetworksBala Chettiar (MTP) Full Type Approval Rejected VRCGRP-1010570 NA NA
Victorian Rail & Civil
SuppliesAustralia/China
00775 1 Axis Q3615-VE PTRZ cameraAn IP Dome Camera with H.264, 1080p, PoE, and supports Axis Lightfinder and WDR -
Forensic Capture with optimal image quality in difficult light conditions.OCS Damien Watson Engineering Product Approval Approved 15/05/2019 Q3615-VE NA NA Axis Sweden
00774 1 Olex Shielded Multicore - 10,20 and 50 Core Shielded CableOutdoor shielded multicore cable for signalling system use on Surface areas only. MTP – RSA intended use is for cabling between new
equipment housing and existing wayside signalling equipment housing controlling the existing wayside equipment.Signals Akshaya Malaviya Engineering Product Approval In Progress
PDQP05RD010BZBM,
PDQP05RD020BZBM,
PDQP05RD050BZBM
NA NA Olex Australia
00773 1 Cubis Single Cavity Square Ducting (SCSD)
SCSD is a single cavity square ducting with a 110x110mm internal profile in the 110 type duct. SCSD is designed to be an above and below
ground ducting solution. Constructed from UPVC, SCSD is strong enough to support a cable weight up to 4kg/m over a 3m span when used in
elevated mounting situation.
MultipleLee Charnock/Mark
ColeFull Type Approval In Progress SCSD110 NA NA Cubis Systems Australia
00772 1 UGL 1500V 4MW Wall Mount Rectifier Front access only (suitable for mounting against wall).Electrical
NetworksZahra Bayat Full Type Approval In Progress NA NA NA UGL Australia
00771 1 Dropper Clip
The 181mm² dropper clip was designed in 1982 by the Victorian Railways manufactured out of Copper-Nickle-Silicon (CuNi2Si).
Dropper clips form part of the dropper assembly. The dropper assembly attaches to the catenary wire and contact wire and supports the contact
wire weight.
Electrical
NetworksMD Mahfuzul Full Type Approval In Progress Q6823 NA NA Australian Brass / Kruch Australia/Austria
00770 1 Wago (Dold) Relay Assembly (Changeover Module)
The relay proposed to go through type approval is a Dold brand relay mounted on a Wago terminal. The relay has 4 front and 4 back contacts
and is classified as safety relay with forcibly guided contacts that mechanically prevent back contact to be made if the front contact is welded and
vice versa. The relay is proposed to be used for a specific application which is to changeover the output between revenue service object
controller and test/trial object controller during trial or pre-testing stage and to disconnect/reconnect the power for revenue service object
Signals Gail Smith Full Type Approval Approved 24/10/2019 786-387 NA NA Wago Germany
00769 1 Transient Protection Equipment
Update to the existing Frauscher axle counter type approval. Under current design, RSA implementation of the Bombardier EBILock950
interlocking requires the use of Frauscher COM-FSE101 board. COM-xxx is used to describe any protocol specific COM board used to
communicate with the interlocking as part of FAdC (D21008 Version 3).Signals Gail Smith Grandfather Rights Approved 9/09/2019 Refer to the attached Certificate NA NA Transient Controls Australia Australia
00768 1 Frauscher COM-FSE101
Update to the existing Frauscher axle counter type approval. Under current design, RSA implementation of the Bombardier EBILock950
interlocking requires the use of Frauscher COM-FSE101 board. COM-xxx is used to describe any protocol specific COM board used to
communicate with the interlocking as part of FAdC (D21008 Version 3).Signals TBC Full Type Approval Registered COM-FSE101 GS03 NA NA Frauscher Australia
00767 1 Milspec Octagonal tilting mast
Tilting mast of 5520 metre height to support mounting of two WiFi Antennas.
The tilt mast is a new type of mast developed specifically for antenna installation purpose. The principle of the mast is the same as the existing
signal tilt mast but it does not include any tilting detection and is lighter weight as the antenna is a lot lighter.
Signals TBC Full Type Approval Approved 22/11/2019 NA NA NA Milspec Australia
00766 1 Pandrol Balise Mounting System (For Noming Point Tag)
Balises or Norming Points (NP) for CBTC systems are a semi-passive tag (RF tags) placed at track level between the two rails, similar to the
TrackLink 3 Tag’s currently type approved for use with HCMT operations. The Rail Systems Alliance intend to install the TagMaster 149800
RailTag for the CBTC system on the Metro Tunnel Project corridor.
Signals TBC Full Type Approval Approved 22/11/2019
116-0290 Double Oversleeper E-
clip Beam Norming Point Tag.
BS120001.NA NA
00765 1 TMC 8kVA 110/230V Single Phase Dry TypeFor the provision of 230 volt general purpose power to the signalling relocatable equipment buildings (REB’s) from the ESDS system or street
supplies.
Electrical
NetworksOut of session Full Type Approval Approved 20/09/2019 20/09/2020 31918 NA NA TMC Australia
00764 1 TMC 8kVA 240/240V Single Phase Dry TypeFor the provision of 240 volt general purpose power to the signalling relocatable equipment buildings (REB’s) from the ESDS system or street
supplies.
Electrical
NetworksOut of session Full Type Approval Approved 20/09/2019 20/09/2020 31898 NA NA TMC Australia
00763 1 Shell GadusRail S2 Wheel Flange Grease
Shell GadusRail S2 Wheel Flange greases are lithium soap greases fortified with a specifically formulated multipurpose additive package and
3% molybdenum disulphide for use as railroad track lubricants. The molybdenum disulphide acts to enhance anti-wear and load carrying
properties, which are critical for the transport of railcars over the track. A highly shear stable tackifier improves grease adhesion to track
surfaces and helps prevent oil bleeding. These greases also offer good resistance to the mechanical shear associated with trackside lubricator
Track Nathan Baker Full Type Approval Registered 001D8470 NA NA Shell USA
00762 1Custom Standalone Off Grid Solar Generation System
(SOGSGS)
Standalone independent battery backed solar generation plant with the ability to supply power for Air-conditioning, general lighting and 240vac
power to remotely located REB -Relocatable Equipment Building (Signal).Signals TBC Full Type Approval Registered NA NA One Team Australia
00761 1 FLIR FC-ID Thermal camera FC-690-ID-P
FLIR FC-ID is an outdoor Thermal camera which comes with configurable analytics that aids in detection. It uses heat to detect objects in its
field of view.
To be used on the Trial U-trough Intruder detection system, to be mounted on the overhead on the down end looking at the u-trough entrance on
OCS Damien Watson Engineering Product Approval Approved 28/10/2019 NA NA FLIR Estonia
00760 1 Axis Camera D2050-VE
AXIS D2050-VE is an outdoor-ready Network Radar Detector as well as providing HDTV 1080p video. The Radar provides a 120˚ horizontal
coverage.
To be used on the Trial U-trough Intruder detection system, to be mounted on the overhead on the down end looking at the u-trough entrance on
OCS Damien Watson Engineering Product Approval Approved 13/11/2019 NA NA Axis Sweden
00759 1 Axis Camera Q1942-E
AXIS Q1942-E is an outdoor bullet style Thermal Camera with a resolution of 640x480 and built-in window heater for harsh weather.
To be used on the Trial U-trough Intruder detection system, to be mounted on the overhead on the down end looking at the u-trough entrance on
Mernda Station.
OCS TBC TBC Approved 28/10/2019 NA NA Axis Sweden
00758 1 Arthur Flury ZS1.5 Section Insulator
The Arthur Flury ZS1.5 is a high-speed section insulator for electrical overhead system. It had been type approved and used in MTM network
extensively over many years. However, as Arthur Flury has now developed a new improved version, the old version will be phased out by the end
of 2019. This form is for the purpose of type approving the new ZS1.5 for use in new projects. (Product support for old model will continue for at
least until 2029 i.e. runner can still be purchased).
Overhead Max Glanville Full Type Approval Approved 26/11/2019 655.400.041 NA NA Arthur Flury AG Switzerland
00757 1 Sick Lidar LMS511
The Sick Lidar is a light-based object detection device that will scan a 2D plane and give feedback on objects that have broken the line of sight of
the device.
The device is to be trialled as part of an intruder detection system for U-troughs. Other applications are possible, but will require a separate type
OCS Damien Watson Engineering Product Approval Approved 13/11/2019 NA NA Sick Germany
00756 1 Anixter Cables - CTD Projects Provisional TA Anixter Cables SignalsLee Charnock/Colin
WatersProvisional Type Approval Approved 10/04/2019 10/04/2020 Refer to Appendix A NA NA Zhongli Group China
00755 1 FLIR FC-ITS Thermal camera FC-644-ITS
FLIR FC-ITS is an outdoor Thermal camera which comes with configurable analytics that aids in detection. It uses heat to detect objects in its
field of view. The FC-ITS model in particular is specialised for Rail application.
To be used on the Trial U-trough Intruder detection system, to be mounted on the overhead on the down end looking at the u-trough entrance on
OCS Damien Watson Engineering Product Approval Approved 28/10/2019 NA NA FLIR Estonia
00754 1 Sick Radar RMS320
The Sick Radar is a radar-based object detection device that emits radar waves and measures the timing of reflections in order to determine
where objects are in its field of view.
The device is to be trialled as part of an intruder detection system for U-troughs. Other applications are possible but will require a separate type
OCS Damien Watson Engineering Product Approval Approved 13/11/2019 NA NA Sick Germany
00753 1 Axis Camera P1445-LE
AXIS P1445-LE Network Camera is an outdoor-ready fixed dome providing HDTV 1080p video. The camera features a varifocal lens for remote
focus and zoom, and day/night functionality. Equipped with WDR to handle scenes with strong light variations, and Lightfinder technology for
exceptional light sensitivity, this camera provides outstanding video quality in both strong and poor light conditions.OCS Damien Watson Engineering Product Approval Registered NA NA Axis Sweden
Please refer to L1-CHE-PRO-004 for T.A Procedure
Uncontrolled if printed. Controlled by MTM Eng. Systems (OCE)
Page 2 of 22 [email protected]
Metro Trains Melbourne Engineering Approved Product List As of 20/01/2020 (Updated monthly)
TA
NumberIssue Title/Product Function/Application(s)
Applicable
System(s)SME Approval Type Approval Status
Approval/Rejected
DateExpiry
Withdrawal/Suspension
DateType/Model Number
Hardware
Revision No.
Software Version
No.Manufacturer Place of Manufacture Condition and Service Restrictions
00752 1Single Core 35mm2 XLPE Insulated Copper Wire Screened
and PVC Sheathed Cable
Single Core
Conductor: Stranded Compacted Copper
Nominal Conductor Area: 35 mm2
Nominal Copper Wire Screen Area: 35 mm2
Substations Zahra Bayat Engineering Product Approval In Progress HV19153C22PVC NA NA CMI Electrical Products Republic of Korea
00751 1 WeldLok Fibreglass Walkway GratingWeldlock Fibre Reinforced Plastic(FRP) square grating offers a suitable option for walkways in locations where track condition has resulted in
the deterioration of existing asphalt pathways.Track Nathan Baker Grandfather Rights Approved 19/09/2019 NA NA NA
Nepean Building and
InfrastructureAustralia
00750 1 Secheron DC Breaker (MBS500 ESTRA-MBS-HD)
DC switchgear panels type ESTRA-MBS-HD intended for use as various DCCB panels (Rectifier, Feeder, BusShort Switch, Bus-Tie etc.).
Panels are equipped with fault-make shorting switches providing reliable positive-to-negative bonding. Microprocessor based, modular relay with
integrated PLC type Sepcos used as protection relay.
Substations Chong Zhou Full Type Approval Approved 14/10/2019 ESTRA-MBS-HD V3 NA Secheron SA Czech Republic
00749 1 Eaton 3kVA Bypass SwitchThe Eaton bypass switch allows for loads connected to a UPS to be (manually) diverted to allow for maintenance activities to be carried out on
the UPS without affecting the connected loads.OCS Niels Endres Engineering Product Approval In Progress MBP3KIER1351 NA NA Eaton China
00748 1 HEXT-70 HDMI ExtenderThis device extends the HDMI video signal upto 35mtrs. This extender is combination of sender(C8E5ED0110) and receiver (C8E5ED0112)
units, connected by Ethernet cable and needs power at only sender or the receiver units, called as Phantom Power.OCS Damien Watson Engineering Product Approval In Progress HEXT-70 B1 NA ICP Global OEM Taiwan
00747 1 Draco Vario 483 series ExtenderThis device extends the Keyboard and mouse along with DP video. This extender is combination of sender(L483) and receiver(R483) units,
connected by Ethernet cable and needs power at both sender and receiver units.OCS Damien Watson Engineering Product Approval In Progress L & R483-1SHC V1.0 V3.06 IHSE GmbH Germany
00746 1 Lockwood Synergy Mortice Lock
Suitable for heavy duty use in industrial and commercial buildings, institutions, clubs, schools, hospitals, hotels, and similar buildings.
3570 Series Cylinder Mortice Locks are made from quality materials to meet high durability and strength requirements.
Designed to enable emergency services to enter specific areas by second cylinder without giving access to all locksets in the building and the
ability to lockout keys with restricted access at certain times.
OCS TBC Engineering Product Approval In Progress3577 Dual Entry Deadlatch
Mortice LockNA NA Assa Abloy Australia
00745 1 Microlok II (Incl. lFDC3 and protocol converter) A CBI Interlocking. SignalsLee Charnock/Colin
WatersFull Type Approval In Progress
00744 1 RSTi-EP Remote I/O
Remote I/O device which provides I/O expansion for a PLC, connected via an Ethernet/ProfiNet network.
EPXPNS001 can controlled by one upstream PLC.
EPXPNS101 can be controlled by two PLCs (for S2 redundancy).
OCS Niels Endres Full Type Approval In Progress EPXPNS001 and EPXPNS101 NA NA Emerson / General Electric Germany
00743 1AEG Protect 4.33 Essential Services Distribution System
Supply UPSSupply of 2.2kV, 3.3kV and 650V Essential Services Distribution System via a compatible step up transformer. Substations Zahra Bayat Provisional Type Approval Approved 12/07/2019 12/01/2020 NA NA NA AEG Power Solutions Germany
00742 1 Siemens Super Capacitor A CBI Battery backup (not a UPS) Signals Gail Smith Full Type Approval In Progress NA NA NA Siemens Germany
00741 1 Voestalpine Trainstop Monitoring Roadmaster Minilogger A Minilogger for OCMS SignalsLee Charnock/Colin
WatersGrandfather Rights In Progress NA NA NA Voestalpine Germany
00740 1 Siemens Signal Mast with Disconnection Box
The product is a complete Signal Mast package, specifically the lockable junction box as per L1-CHE-GDL-074 – Chief Engineers Directive
Signal Mast Types and Applications.
It will avoid the need to retrofit a standard telephone box onto the currently type approved signal mast.
Signals Gail Smith Full Type Approval In Progress NA NA NA Siemens Australia
00739 1 Siemens M23 Mk3 Siemens Point Machine A mainline point machine (M23 Mk2-Mk3 production evolution update) SignalsLee Charnock/Colin
WatersGrandfather Rights In Progress NA NA NA Siemens Australia
00738 1 Line Identification Signboard (LIS)Signs to inform the driver the identification of the line to which it refers. The identity shall be that used for signals on a gantry with reduced
sightings capabilities.Signals
Lee Charnock/Colin
WatersGrandfather Rights In Progress NA NA NA Siemens Australia
00737 1 Siemens Sigmaguard LED Indicator Signal Indicator for lineside signalling. An electronic equivalent of a semaphore repeat indicator is created from an array of high-intensity LEDs. SignalsLee Charnock/Colin
WatersGrandfather Rights Approved 30/10/2019 NA NA NA Siemens Australia
00736 1 TMC 250kVA ESS Transformer To convert from 22000V to 400V at rating of 250kVA, to be used for auxiliary or essential services within a railway substation SubstationsJames Webb/Craig
TookeFull Type Approval Approved 14/11/2019 TMT0525022-BD-IP21-Dyn1 NA NA TMC Australia
00735 1 TMC 300kVA ESS Transformer To convert from 22000V to 400V at rating of 300kVA, to be used for auxiliary or essential services within a railway substation Signals Craig Tooke Full Type Approval Approved 11/06/2019TMT0530022-BD-IP21-Dyn1
TMT0530022-AD-IP43-Dyn1NA NA TMC Australia
00734 1 Alstom RailView Train Control SystemThe Alstom RailView Train Control System (TCS) is a Personal Computer (PC) based control panel used to control and monitor the railway
through a signalling interlocking system. Signals
Wayne Purton/Lee
CharnockProvisional Type Approval Approved 15/07/2019 15/07/2020 Alstom RailView NA NA Alstom Australia
00733 1 ABLOY-PDA500 Administrator programming device OCS Mark Cole Grandfather Rights Approved 8/02/2019 PDA500 NA NA ASSA ABLOY Sweden Administrator use only
00732 1 ABLOY-PDA110/ACDC/KIT CLIQ Wall PD with CLIQ key reader with AC DC kit if PoE is not available OCS Mark Cole Grandfather Rights Approved 8/02/2019 PDA110/ACDC/KIT NA NA ASSA ABLOY SwedenCLIQ wall PD shall only be installed inside a secure building with the CLIQ reader installed external
to the building
00731 1 ABLOY-PDA110 CLIQ Wall PD with CLIQ key reader OCS Mark Cole Grandfather Rights Approved 8/02/2019 PDA110 NA NA ASSA ABLOY SwedenCLIQ wall PD shall only be installed inside a secure building with the CLIQ reader installed external
to the building
00730 1 ABLOY-PDA100/ACDC/KIT CLIQ Wall PD with AC DC kit if PoE is not available OCS Mark Cole Grandfather Rights Approved 8/02/2019 PDA100/ACDC/KIT NA NA ASSA ABLOY Sweden CLIQ wall PD shall only be installed inside a secure building
00729 1 ABLOY-PDA100 CLIQ Wall PD OCS Mark Cole Grandfather Rights Approved 8/02/2019 PDA100 NA NA ASSA ABLOY Sweden CLIQ wall PD shall only be installed inside a secure building
00728 1 ABLOY-TQ407/[Profile) CLIQ Protec2 Dynamic user key (e.g. TQ407/TH11AA) OCS Mark Cole Grandfather Rights Approved 8/02/2019 TQ407/[Profile) NA NA ASSA ABLOY Sweden Order to Profile
00727 1 ABLOY-TQ406/[Profile] CLIQ Protec2 Normal user key (e.g. TQ406/TH11AA) OCS Mark Cole Grandfather Rights Approved 8/02/2019 TQ406/[Profile] NA NA ASSA ABLOY Sweden Order to Profile
00726 1 ABLOY-PLLW330T/50/G CLIQ Protec2 PLLW330. Padlock 50mm Vert, 25mm H clearance with chain OCS Mark Cole Grandfather Rights Approved 8/02/2019 PLLW330T/50/G NA NA ASSA ABLOY Sweden Assembled to code
00725 1 ABLOY-PLLW330T/50 CLIQ Protec2 PLLW330. Padlock 50mm Vert, 25mm H clearance OCS Mark Cole Grandfather Rights Approved 8/02/2019 PLLW330T/50 NA NA ASSA ABLOY Sweden Assembled to code
00724 1 ABLOY-PLLW330T/25 CLIQ Protec2 PLLW330. Padlock 25mm H&V clearance OCS Mark Cole Grandfather Rights Approved 8/02/2019 PLLW330T/25 NA NA ASSA ABLOY Sweden Assembled to code
00723 1 ABLOY-PL330T/50/G Protec2 PADLCK 50MM ST SHKL MK with chain OCS Mark Cole Grandfather Rights Approved 8/02/2019 PL330T/50/G NA NA ASSA ABLOY Sweden Assembled to code
00722 1 ABLOY-PL330T/50 Protec2 PADLCK 50MM ST SHKL MK OCS Mark Cole Grandfather Rights Approved 8/02/2019 PL330T/50 NA NA ASSA ABLOY Sweden Assembled to code
00721 1 ABLOY-PL330T/25 Protec2 PADLCK 25MM ST SHKL MK OCS Mark Cole Grandfather Rights Approved 8/02/2019 PL330T/25 NA NA ASSA ABLOY Sweden Assembled to code
00720 1 ABLOY-CYL323T/LRCPCLIQ Protec2 CYL323 Construction Cylinder Turn Lazy Cam Right Hand - NOTE: For dust and water protected cylinders, include "P" in part
number. E.g. CYLP504T/XSCOCS Mark Cole Grandfather Rights Approved 8/02/2019 CYL323T/LRCP NA NA ASSA ABLOY Sweden Assembled to code
00719 1 ABLOY-CYL323T/LLCPCLIQ Protec2 CYL323 Construction Cylinder Turn Lazy Cam Left Hand - NOTE: For dust and water protected cylinders, include "P" in part
number. E.g. CYLP504T/XSCOCS Mark Cole Grandfather Rights Approved 8/02/2019 CYL323T/LLCP NA NA ASSA ABLOY Sweden Assembled to code
00718 1 ABLOY-CYL323T/FCPCLIQ Protec2 CYL323 Construction Cylinder Turn Fixed Cam - NOTE: For dust and water protected cylinders, include "P" in part number. E.g.
CYLP504T/XSCOCS Mark Cole Grandfather Rights Approved 8/02/2019 CYL323T/FCP NA NA ASSA ABLOY Sweden Assembled to code
00717 1 ABLOY-CYL322T/LCPCLIQ Protec2 CYL322 Construction Cylinder Doublr Cyl Lazy Cam - NOTE: For dust and water protected cylinders, include "P" in part number.
E.g. CYLP504T/XSCOCS Mark Cole Grandfather Rights Approved 8/02/2019 CYL322T/LCP NA NA ASSA ABLOY Sweden Assembled to code
00716 1 ABLOY-CYL322T/FCPCLIQ Protec2 CYL322 Construction Cylinder Doublr Cyl Lazy Cam - NOTE: For dust and water protected cylinders, include "P" in part number.
E.g. CYLP504T/XSCOCS Mark Cole Grandfather Rights Approved 8/02/2019 CYL322T/FCP NA NA ASSA ABLOY Sweden Assembled to code
00715 1 ABLOY-CYL321T/LRCPCLIQ Protec2 CYL321 Construction Cylinder Half Cyl Lazy Cam Right Hand - NOTE: For dust and water protected cylinders, include "P" in part
number. E.g. CYLP504T/XSCOCS Mark Cole Grandfather Rights Approved 8/02/2019 CYL321T/LRCP NA NA ASSA ABLOY Sweden Assembled to code
00714 1 ABLOY-CYL321T/LLCPCLIQ Protec2 CYL321 Construction Cylinder Half Cyl Lazy Cam Left Hand - NOTE: For dust and water protected cylinders, include "P" in part
number. E.g. CYLP504T/XSCOCS Mark Cole Grandfather Rights Approved 8/02/2019 CYL321T/LLCP NA NA ASSA ABLOY Sweden Assembled to code
00713 1 ABLOY-CYL321T/FCPCLIQ Protec2 CYL321 Construction Cylinder Half Cyl Fixed Cam - NOTE: For dust and water protected cylinders, include "P" in part number.
E.g. CYLP504T/XSCOCS Mark Cole Grandfather Rights Approved 8/02/2019 CYL321T/FCP NA NA ASSA ABLOY Sweden Assembled to code
00712 1 ABLOY-CY323T/LRCPProtec2 CY323 Construction Cylinder Turn Lazy Cam Right Hand - NOTE: For dust and water protected cylinders, include "P" in part number.
E.g. CYLP504T/XSCOCS Mark Cole Grandfather Rights Approved 8/02/2019 CY323T/LRCP NA NA ASSA ABLOY Sweden Assembled to code
00711 1 ABLOY-CY323T/LLCPProtec2 CY323 Construction Cylinder Turn Lazy Cam Left Hand - NOTE: For dust and water protected cylinders, include "P" in part number.
E.g. CYLP504T/XSCOCS Mark Cole Grandfather Rights Approved 8/02/2019 CY323T/LLCP NA NA ASSA ABLOY Sweden Assembled to code
Please refer to L1-CHE-PRO-004 for T.A Procedure
Uncontrolled if printed. Controlled by MTM Eng. Systems (OCE)
Page 3 of 22 [email protected]
Metro Trains Melbourne Engineering Approved Product List As of 20/01/2020 (Updated monthly)
TA
NumberIssue Title/Product Function/Application(s)
Applicable
System(s)SME Approval Type Approval Status
Approval/Rejected
DateExpiry
Withdrawal/Suspension
DateType/Model Number
Hardware
Revision No.
Software Version
No.Manufacturer Place of Manufacture Condition and Service Restrictions
00710 1 ABLOY-CY323T/FCPProtec2 CY323 Construction Cylinder Turn Fixed Cam - NOTE: For dust and water protected cylinders, include "P" in part number. E.g.
CYLP504T/XSCOCS Mark Cole Grandfather Rights Approved 8/02/2019 CY323T/FCP NA NA ASSA ABLOY Sweden Assembled to code
00709 1 ABLOY-CY322T/LCPProtec2 CY322 Construction Cylinder Doublr Cyl Lazy Cam - NOTE: For dust and water protected cylinders, include "P" in part number. E.g.
CYLP504T/XSCOCS Mark Cole Grandfather Rights Approved 8/02/2019 CY322T/LCP NA NA ASSA ABLOY Sweden Assembled to code
00708 1 ABLOY-CY322T/FCPProtec2 CY322 Construction Cylinder Doublr Cyl Lazy Cam - NOTE: For dust and water protected cylinders, include "P" in part number. E.g.
CYLP504T/XSCOCS Mark Cole Grandfather Rights Approved 8/02/2019 CY322T/FCP NA NA ASSA ABLOY Sweden Assembled to code
00707 1 ABLOY-CY321T/LRCPProtec2 CY321 Construction Cylinder Half Cyl Lazy Cam Right Hand - NOTE: For dust and water protected cylinders, include "P" in part
number. E.g. CYLP504T/XSCOCS Mark Cole Grandfather Rights Approved 8/02/2019 CY321T/LRCP NA NA ASSA ABLOY Sweden Assembled to code
00706 1 ABLOY-CY321T/LLCPProtec2 CY321 Construction Cylinder Half Cyl Lazy Cam Left Hand - NOTE: For dust and water protected cylinders, include "P" in part number.
E.g. CYLP504T/XSCOCS Mark Cole Grandfather Rights Approved 8/02/2019 CY321T/LLCP NA NA ASSA ABLOY Sweden Assembled to code
00705 1 ABLOY-CY321T/FCPProtec2 CY321 Construction Cylinder Half Cyl Fixed Cam - NOTE: For dust and water protected cylinders, include "P" in part number. E.g.
CYLP504T/XSCOCS Mark Cole Grandfather Rights Approved 8/02/2019 CY321T/FCP NA NA ASSA ABLOY Sweden Assembled to code
00704 1 ABLOY-CYL/CLIQ2LIW/SC CLIQ Protec2 LIW K/Switch CYL MK - NOTE: For dust and water protected cylinders, include "P" in part number. E.g. CYLP504T/XSC OCS Mark Cole Grandfather Rights Approved 8/02/2019 CYL/CLIQ2LIW/SC NA NA ASSA ABLOY Sweden Assembled to code
00703 1 ABLOY-CYLIWT/SC CLIQ Protec2 CYLIW Construction Cylinder - NOTE: For dust and water protected cylinders, include "P" in part number. E.g. CYLP504T/XSC OCS Mark Cole Grandfather Rights Approved 8/02/2019 CYLIWT/SC NA NA ASSA ABLOY Sweden Assembled to code
00702 1 ABLOY-CYIWT/SC Protec2 CYIW Construction Cylinder - NOTE: For dust and water protected cylinders, include "P" in part number. E.g. CYLP504T/XSC OCS Mark Cole Grandfather Rights Approved 8/02/2019 CYIWT/SC NA NA ASSA ABLOY Sweden Assembled to code
00701 1 ABLOY-CYL801T/SC CLIQ Protec2 CYL801 Construction Cylinder - NOTE: For dust and water protected cylinders, include "P" in part number. E.g. CYLP504T/XSC OCS Mark Cole Grandfather Rights Approved 8/02/2019 CYL801T/SC NA NA ASSA ABLOY Sweden Assembled to code
00700 1 ABLOY-CY801T/SC Protec2 CY801 Construction Cylinder - NOTE: For dust and water protected cylinders, include "P" in part number. E.g. CYLP504T/XSC OCS Mark Cole Grandfather Rights Approved 8/02/2019 CY801T/SC NA NA ASSA ABLOY Sweden Assembled to code
00699 1 ABLOY-CYL504TEX/XSCCLIQ Protec2 CYL504 Extendable oval cylinder with X cam MK - NOTE: For dust and water protected cylinders, include "P" in part number. E.g.
CYLP504T/XSCOCS Mark Cole Grandfather Rights Approved 8/02/2019 CYL504TEX/XSC NA NA ASSA ABLOY Sweden Assembled to code
00698 1 ABLOY-CYL504T50/XSCCLIQ Protec2 CYL504EX 50mm long with X cam MK - NOTE: For dust and water protected cylinders, include "P" in part number. E.g.
CYLP504T/XSCOCS Mark Cole Grandfather Rights Approved 8/02/2019 CYL504T50/XSC NA NA ASSA ABLOY Sweden Assembled to code
00697 1 ABLOY-CYL504T/NCSCCLIQ Protec2 CYL504 Construction Cylinder no cam - NOTE: For dust and water protected cylinders, include "P" in part number. E.g.
CYLP504T/XSCOCS Mark Cole Grandfather Rights Approved 8/02/2019 CYL504T/NCSC NA NA ASSA ABLOY Sweden Assembled to code
00696 1 ABLOY-CYL504T/ZSCCLIQ Protec2 CYL504 Construction Cylinder Z cam - NOTE: For dust and water protected cylinders, include "P" in part number. E.g.
CYLP504T/XSCOCS Mark Cole Grandfather Rights Approved 8/02/2019 CYL504T/ZSC NA NA ASSA ABLOY Sweden Assembled to code
00695 1 ABLOY-CYL504T/YSCCLIQ Protec2 CYL504 Construction Cylinder Y cam - NOTE: For dust and water protected cylinders, include "P" in part number. E.g.
CYLP504T/XSCOCS Mark Cole Grandfather Rights Approved 8/02/2019 CYL504T/YSC NA NA ASSA ABLOY Sweden Assembled to code
00694 1 ABLOY-CYL504T/XSCCLIQ Protec2 CYL504 Construction Cylinder X cam - NOTE: For dust and water protected cylinders, include "P" in part number. E.g.
CYLP504T/XSCOCS Mark Cole Grandfather Rights Approved 8/02/2019 CYL504T/XSC NA NA ASSA ABLOY Sweden Assembled to code
00693 1 ABLOY-CYL504T/WSCCLIQ Protec2 CYL504 Construction Cylinder W cam - NOTE: For dust and water protected cylinders, include "P" in part number. E.g.
CYLP504T/XSCOCS Mark Cole Grandfather Rights Approved 8/02/2019 CYL504T/WSC NA NA ASSA ABLOY Sweden Assembled to code
00692 1 ABLOY-CYL504T/RSCCLIQ Protec2 CYL504 Construction Cylinder R cam - NOTE: For dust and water protected cylinders, include "P" in part number. E.g.
CYLP504T/XSCOCS Mark Cole Grandfather Rights Approved 8/02/2019 CYL504T/RSC NA NA ASSA ABLOY Sweden Assembled to code
00691 1 ABLOY-CYL504T/MSCCLIQ Protec2 CYL504 Construction Cylinder M cam - NOTE: For dust and water protected cylinders, include "P" in part number. E.g.
CYLP504T/XSCOCS Mark Cole Grandfather Rights Approved 8/02/2019 CYL504T/MSC NA NA ASSA ABLOY Sweden Assembled to code
00690 1 ABLOY-CYL504T/USCCLIQ Protec2 CYL504 Construction Cylinder U cam - NOTE: For dust and water protected cylinders, include "P" in part number. E.g.
CYLP504T/XSCOCS Mark Cole Grandfather Rights Approved 8/02/2019 CYL504T/USC NA NA ASSA ABLOY Sweden Assembled to code
00689 1 ABLOY-CY504TEX/XSCProtec2 CY504 Extendable oval cylinder with X cam MK - NOTE: For dust and water protected cylinders, include "P" in part number. E.g.
CYLP504T/XSCOCS Mark Cole Grandfather Rights Approved 8/02/2019 CY504TEX/XSC NA NA ASSA ABLOY Sweden Assembled to code
00688 1 ABLOY-CY504T50/XSCProtec2 CY504EX 50mm long with X cam MK - NOTE: For dust and water protected cylinders, include "P" in part number. E.g.
CYLP504T/XSCOCS Mark Cole Grandfather Rights Approved 8/02/2019 CY504T50/XSC NA NA ASSA ABLOY Sweden Assembled to code
00687 1 ABLOY-CY504T/NCSC Protec2 CY504 Construction Cylinder no cam - NOTE: For dust and water protected cylinders, include "P" in part number. E.g. CYLP504T/XSC OCS Mark Cole Grandfather Rights Approved 8/02/2019 CY504T/NCSC NA NA ASSA ABLOY Sweden Assembled to code
00686 1 ABLOY-CY504T/ZSC Protec2 CY504 Construction Cylinder Z cam - NOTE: For dust and water protected cylinders, include "P" in part number. E.g. CYLP504T/XSC OCS Mark Cole Grandfather Rights Approved 8/02/2019 CY504T/ZSC NA NA ASSA ABLOY Sweden Assembled to code
00685 1 ABLOY-CY504T/YSC Protec2 CY504 Construction Cylinder Y cam - NOTE: For dust and water protected cylinders, include "P" in part number. E.g. CYLP504T/XSC OCS Mark Cole Grandfather Rights Approved 8/02/2019 CY504T/YSC NA NA ASSA ABLOY Sweden Assembled to code
00684 1 ABLOY-CY504T/XSC Protec2 CY504 Construction Cylinder X cam - NOTE: For dust and water protected cylinders, include "P" in part number. E.g. CYLP504T/XSC OCS Mark Cole Grandfather Rights Approved 8/02/2019 CY504T/XSC NA NA ASSA ABLOY Sweden Assembled to code
00683 1 ABLOY-CY504T/WSC Protec2 CY504 Construction Cylinder W cam - NOTE: For dust and water protected cylinders, include "P" in part number. E.g. CYLP504T/XSC OCS Mark Cole Grandfather Rights Approved 8/02/2019 CY504T/WSC NA NA ASSA ABLOY Sweden Assembled to code
00682 1 ABLOY-CY504T/RSC Protec2 CY504 Construction Cylinder R cam - NOTE: For dust and water protected cylinders, include "P" in part number. E.g. CYLP504T/XSC OCS Mark Cole Grandfather Rights Approved 8/02/2019 CY504T/RSC NA NA ASSA ABLOY Sweden Assembled to code
00681 1 ABLOY-CY504T/MSC Protec2 CY504 Construction Cylinder M cam - NOTE: For dust and water protected cylinders, include "P" in part number. E.g. CYLP504T/XSC OCS Mark Cole Grandfather Rights Approved 8/02/2019 CY504T/MSC NA NA ASSA ABLOY Sweden Assembled to code
00680 1 ABLOY-CY504T/USC Protec2 CY504 Construction Cylinder U cam - NOTE: For dust and water protected cylinders, include "P" in part number. E.g. CYLP504T/XSC OCS Mark Cole Grandfather Rights Approved 8/02/2019 CY504T/USC NA NA ASSA ABLOY Sweden Assembled to code
00679 1 ABLOY-CYL414T/SC CLIQ Protec2 CYL414 Construction Cylinder - NOTE: For dust and water protected cylinders, include "P" in part number. E.g. CYLP504T/XSC OCS Mark Cole Grandfather Rights Approved 8/02/2019 CYL414T/SC NA NA ASSA ABLOY Sweden Assembled to code
00678 1 ABLOY-CY414T/SCProtec2 CY414 Construction Cylinder (Satin Chrome) - NOTE: For dust and water protected cylinders, include "P" in part number. E.g.
CYLP504T/XSCOCS Mark Cole Grandfather Rights Approved 8/02/2019 CY414T/SC NA NA ASSA ABLOY Sweden Assembled to code
00677 1 Anti Trespasser Panels
Anti-Trespass panels are designed to deter people or animals from crossing the track at unauthorized places. They will fit any rail and sleeper,
are easily installed and cannot be accidentally displaced as they fit under the rail to form a complete matrix across the track. They can be cut to
fit if necessary and can be removed for tamping and replaced without damage.
Track Gordon Djurdjevic Provisional Type Approval Approved 7/10/2019 NA NA NA Rosehill Rail UK
00676 1 Automatic Stabling Train Gates (ASTG)
ASTG is a two leaf swing gate system which operate together ie the system only requires one open command to open both the gates
simultaneously. The gates are operated by an electric motor/gearbox which drives the gates via a lever arm. The lever arm is attached
to the drive shaft of the motor gearbox and onto a lug fixed to the swing gate. The ASTG are required to be interlocked with the local
signalling system through CBI that can be remotely controller by the local signaller’s panel.
Signals Ian Roulstone Grandfather Rights Approved 8/02/2019 NA NA NA Magnetic Autocontrol Australia
00675 1 TrackcoatUrethane resin used to bind ballast stones together. Reduces wear of the ballast in problem areas such as ballast rail coming up to a fixed point
ie railway crossing over road and bridge ends.Track Nathan Baker Provisional Type Approval Withdrawn 10/07/2019 NA NA NA Era Polymers Australia Type approval withdrawn as advised by SME in the attached email 10/07/2019
00674 1 TMC EST (11kV/1000V) Rectifier transformer for use to step-down power from 11kV to 400V Substations
David
Hutchison/Craig
Tooke
Full Type Approval Approved 13/11/2019 TMT-0520011-BD-IP21-Dzn0 NA NA TMC Australia
00673 1 Tortech Isolation Transformer 15kVAIsolation Transformers are used to ensure separation between local electricity distributor’s MEN earth system and the railway network earthing
systems. These are common across the MTM network where LV supplies are derived for a substation or in some cases railway stations. Substations Craig Tooke Full Type Approval In Progress ISO-3PH-15kVA-IP56 NA NA Tortech Pty Ltd Australia
00672 1 Century Yuasa 48V 1Kw DC Battery UXH125-6
48VDC battery and charger panel installed in substations to provide the DC supply for control and protection system on switchgears. The new
combined battery and charger panel reduce the footprint requirement for 48VDC system inside the substation building. All equipment were
included in new design are already type approved by MTM engineering. The only change is in equipment arrangement inside the panel
Overhead Zahra Bayat Full Type Approval Withdrawn 12/07/2019 UXH125-6 NA NA Century Yuasa USA, Japan Type approval withdrawn as advised by SME in the attached email 12/07/2019
00671 1 Relocatable Equipment Building (REB)
Structure to house signalling equipment:
Large (Non fire rated)
Size:
8.7m (L) x 3.3m (W) x 3.55m (H) External Dimensions
8.55mm (L) x 3.15m (W) x 3.0m (Min Height) Internal Dimensions
Weight:
Empty weight – 7500kg
Total weight – 12500kg (with racks and equipment installed)
Wall & Ceiling Type:
Walls 75mm Insulated Panel with XFLAM Core – R = 2.58
Roof: 100mm Insulated Panel with XFLAM Core – R = 3.39
Sloped roof with Colorbond trimline gutter & 100mm x 50mm downpipe
Metal Clad door (2040mm x 905mm) & single galvanised step
Signals Lee Charnock Full Type Approval Registered TBA NA NA ICS Industries Australia
Please refer to L1-CHE-PRO-004 for T.A Procedure
Uncontrolled if printed. Controlled by MTM Eng. Systems (OCE)
Page 4 of 22 [email protected]
Metro Trains Melbourne Engineering Approved Product List As of 20/01/2020 (Updated monthly)
TA
NumberIssue Title/Product Function/Application(s)
Applicable
System(s)SME Approval Type Approval Status
Approval/Rejected
DateExpiry
Withdrawal/Suspension
DateType/Model Number
Hardware
Revision No.
Software Version
No.Manufacturer Place of Manufacture Condition and Service Restrictions
00670 1PULS Power Supplies
(Covered under TA00643 Smartlock GP400)
The PULS power supplies is a wide-range input AC-DC power supply that can be used to provide an adjustable range of outputs and can be
connected in series to produce various voltages as required. As part of the introduction to the Smartlock 400GP and SmartIO object controllers,
the PULS power supply have been chosen due to its tachnical advantages.
SignalsLee Charnock/Colin
WatersFull Type Approval
Suspended (Until Further
Notice)QS10.241 & QS10.481 NA NA PULS Power China/Czech Republic
00669 1 Arthur Flury Low Speed SIArthur Flury (AF) FOK3 655.300.046 Low Speed Section insulator (LSSI) is a direct replacement for the D5484-22 LSSI which is obsolete and
no longer produced by AF. This model SI is suitable for voltages up to 3kV and speeds up to 60kphOverhead Karim Kobrosly Provisional Type Approval Approved 1/03/2019 1/06/2020 655.300.046 NA NA Arthur Flury Switzerland
00668 1 Compulab FITLET2Small industrial rated PC for general use across the OCS Security Network. To be used in new 38” PIDS and for Rapid Deployment CCTV
Systems.OCS Damien Watson Engineering Product Approval Approved 27/02/2019 FITLET2-CJ3455-D4-TE-P36 NA NA Compulab Israel
For dual monitors, a Display Port to HDMI adaptor is needed.
For use in CCTV as a small remote system, it is important to order the additional storage module to
allow recording.
00667 1 Fullriver Dc Series Battery Fullriver DC Series Battery DC180-12 is a sealed battery used for power supply application requiring heavy duty cycling capability SignalsLee Charnock/Colin
WatersEngineering Product Approval Approved 13/03/2019 Dc180-12 NA NA Fullriver China
00666 1 VERSALUX VRL METRO Light Fitting
THIS LIGHT FITTING IS A IP65 TUBULAR LUMINAIRE CONSTRUCTED FROM CLEAR METHACRYLATE. THE LUMINAIRE IS SUPPLIED
WITH TRIDONIC LED BOARD AND TRIDONIC DRIVER SET TO A LEVEL THAT WILL PROVIDE THE REQUIRED LIGHTING LEVEL BUT
STILL PROVIDE LOW GLARE AND MINIMIAL SPILL LIGHT.
Structures Joe Cavric Engineering Product Approval Withdrawn 26/03/2019 16/05/2019 VRL METRO NA NA QA/VERSALUX China/Australia
00665 1 K-ClampA K-CLAMP type line post insulator has been proposed in the Pakenham East HCMT overhead design to register the Stabling yard parafil LED
lighting.
Electrical
NetworksAshley Keep Full Type Approval Rejected 18/04/2019 KL-15SKM20 NA NA K-Line Canada Rejected based on the risks assessed.
00664 1 Metromatics 46" PIDsThe Metrospec 46” PID is an LCD panel allowing for more features such as sunlight viewable, automatic dimming and anti-vandalism features
and provide greater information for customers.OCS Vincent Scotto Engineering Product Approval Approved 27/02/2019 Metrospec H46 NA NA Metrospec Australia
This product can only be used as a replacement device for
maintenance works locations where this type of PID had
Conditions previously been installed.
00663 1 Cordex CXC-HP Battery Controller Card
Charger rectifier’s control unit installed in 48 VDC Charger panel in substations. Please note, existing (CXCM) controller fitted into the rectifier
shelf. However, the new CXC HP controller and associated peripheral devices need to be accommodated elsewhere in the existing DC charger
panel. The CXC HP controller can be incorporated into the escutcheon of the DC distribution board in the DC panel.
Substations Craig Tooke Full Type Approval Approved 3/12/2019 180036 NA NA Alpha Technologies USA
00662 1 Clarage Fan The Clarage fan will be used for the smoke extraction system in the MURL as part of the MURL Fire and Life Project. Structures
Lachlan
Henderson/Amarnat
h Porselvan
Full Type ApprovalSuspended (Until Further
Notice)16/09/2019
Fan – ATV16T723C12A
Fan – ATV18T813C12ANA NA Clarage USA
00661 1 75i AWV Fire & Smoke Damper with Rotork Actuator
The TFD-75i has been developed from the AWV type TFD-75 and TFD-75C Dampers, which have been used on global infrastructure tunnel
projects for 40+ years. The TFD 75i type dampers were designed for fire, isolation, balancing or smoke control/extract applications. They have
been tested with operation by numerous options, e.g.; Electric Spring Return or Double acting electric spring return or double acting.
Structures
Lachlan
Henderson/Amarnat
h Porselvan
Provisional Type Approval Approved 19/12/2018 (AWV) TFD-75i Damper NA NA AWV USA
00660 1 Pandrol Clip Type E2043
The e2043 clip is a steel resilient fastening component manufactured by Pandrol that has the appropriate stiffness to prevent lateral and
longitudinal movement of the track fastening system and sleepers. The clips are applied through lugs on the baseplate (as is the case in the
MURL) or through cast in shoulders.
Track Nathan Baker Provisional Type Approval Withdrawn 16/09/2019 E2043 NA NA Pandrol Australia Pty Limited Australia
00659 1 Manuco 46" PID (Full-size Platform PID)
46” PIDs (Passenger Information Displays) will be used to show static or schedule information regarding the timetables of the trains and real
time information based on the location of the train. This new LCD panel allows greater functionality and information for customers. The LCD
panels are IPx65 rated and are driven by a PC situated within the Panel.
OCS Vincent Scotto Engineering Product Approval Approved 27/11/2018 Q467MS (4T) NA NA Hyundai IT Korea
1. Due to a total weight of 65.5kg (~30kg greater than current PID and 4-line single sided LED
PID), this product can only be installed where support infrastructure to the required engineering
specifications has been provided.
2. This product shall not be used as a maintenance replacement at locations where a PID of lesser
weight has previously been installed until the support infrastructure has been assessed as suitable
to bear the increased load.
00658 1 Panasonic WV-S1131 CameraAn IP Camera with H.264, H.265 4K + 1080p, PoE, and Enhanced Low Light Performance mode. ONVIF compliant, and compatible with our
existing DVTel NVMS.OCS Damien Watson Engineering Product Approval Approved 1/11/2018 WV-S1131 NA NA Panasonic Japan
The camera will be installed in an approved camera housing in order to provide adequate weather
protection and vandal resistance.
Both Computar AG4Z2812FCS-MPIR and the Tamron M13VG850IR will be the only lenses used
with the camera.
00657 1 Vigilant MX1-AU
New Generation of addressable FIP to replace the existing MX4428 which are currently
installed through parliament, flagstaff and Melbourne Central Stations.
This new panel enables backwards/forwards compatibility of existing devices whilst
allowing the most recent technical capabilities available.
Structures Lachlan Henderson Full Type Approval Approved 17/10/2018 MX1-AU NA Firmware 1.7 Vigilant New Zealand
00656 1 IFM 01D100 The IFM O1D range of sensors are photoelectric distance sensors that do not require a reflector or receiver at the remote end. OCS Niels Endres Engineering Product Approval Approved 1/11/2018 01D100 NA NA IFM GermanyIf the sensor is installed in a location subject to vandalism, a protective cover (either model E21133
or model E21171) shall be used.
00655 1 VuePix LED Screen
The VuePix LED Screen is a large billboard-style screen that will display next train information for multiple train lines in the entrance areas of
major stations. It will replace banks of individual PIDs. The screen is made up of 500mm x 500mm and 500mm × 1000mm cabinets that fit
together in any configuration required to form a continuous LED screen.
OCS
Marcus
Morrison/Joseph
Baini
Engineering Product Approval Approved 19/12/2018 ER3 Fixed Install Cabinet NA NA ULA Group China
Product shall only be used once RCM compliance has been confirmed.
Product is only approved for use at Flinders Street Station concourse(s). This product approval
should be reconsidered should the device be requested to be used at any other location
00654 1 Sentry VoIP 2 button PTV
The CHP (Customer Help Point) is designed to provide a connection to the PRIDE information service and an emergency help service. Pressing
the red “emergency” button triggers CCTV cameras in the location. Pressing the green “information” button connects with the PRIDE next train
and service information.
OCS Mark Cole Engineering Product ApprovalSuspended (Until Further
Notice)7/11/2018 SENTRYVOIP2BHPTV NA VoIP V8A Dallas Delta Pty Ltd Australia
There’s a discussion in the ERB that the product is not ready for use in MTM, somewhere along
those line. Requestor is consulting with SME.
SME (Marcus) was going to put something together to address Mark’s concerns. I believe this is
00653 1
1. Matrix Simado GSM Fixed Cellular Terminal Simado GFX
E with battery backup
2. Wall mounted Interquartz Phone IQ333 Analogue Phone
To be installed inside substations and other rooms that require phone call services to speak to 000 or electrol/metrol. OCS Mark Cole Engineering Product Approval Rejected 4/10/2018 NA NA NA Matrix NA
00652 1 Manuco 37" PID (Half-size PID)
37”PIDs (Passenger Information Displays) will be used to show static or schedule information regarding the timetables of the trains and real time
information based on the location of the train. This new LCD panel allows for greater functionality. The LCD panels are IPx65 rated and are
driven by a PC situated within the Panel.
OCS Mark Cole Engineering Product Approval Approved 27/11/2018 H373MD NA NA Hyundai IT Korea
1. Due to a total weight of 62kg (~20kg greater than current ½ height LCD PID and ~40kg greater
than current ½ height LED PID), this product can only be installed where support infrastructure to
the required engineering specifications has been provided.
2. This product shall not be used as a maintenance replacement at locations where a PID of lesser
00651 1 Manuco Driver Platform Display21” LCD Monitors for use as SPOT Monitors in order to give drivers vision (from the driver cabin) of curved platforms so as to ensure platforms
are clear before departing. OCS Mark Cole Engineering Product Approval Approved 16/01/2019 NA LYNX-215FHD-MET NA NA Manuco Taiwan
00650 1 Kontakt.io Beacon
Beacons are low-cost, low-powered transmitters equipped with Bluetooth Low Energy or BLE (also called Bluetooth 4.0 or Bluetooth Smart) that
can be used to deliver proximity-based, context-aware messages. A beacon transmits signals, which allows another device to determine its
proximity to the broadcaster. In a store, a beacon lets a customer’s app determine that it is close to a particular aisle, or in a particular
department. The beacon does not transmit content; it simply transmits a signal that lets a user’s phone or tablet figure out what is the content
OCS Mark Cole Engineering Product Approval Approved 6/02/2019 NA NA NA NA Kontakt.io Europe1. Devices shall only be placed in locations that do not hinder MTM operations or maintenance
2. All maintenance activities associated with the device shall be GDV responsibility.
00649 1 Vortok Safety BarrierVortok Safet Barrier is used as an alternative to using 'para webbing and star pickets' to delineate mainline train movements and any
construction works along the rail corridor.Track Mark Brookshaw Grandfather Rights Approved 8/07/2011 256/2011 NA NA Vortok UK
00648 1 Siemens Smart KVI Switch DPN-4Quad is a dedicated multi-platform KVM switch capable of managing up to 4 different computers through four DisplayPort monitors, one
USB keyboard & mouse, a single set of speakers and a USB 2.0 Device.OCS Mark Cole Engineering Product Approval Registered Smart-AVI KVI Switch DPN-4Q NA NA SMARTAVI USA
00647 1 Extreme X440-G2 Series Switch and Modules
X440-G2 Series provides Ethernet Copper and Fibre connectivity up to 1 Gbps (standard) or upgraded to 10 Gbps with software license. The
X440-G2 Series provides both Layer 2 Ethernet communications capabilities (LAN access) as well as Layer 3 Ethernet switch / router
functionality (WAN access)
OCSMark Cole/Damien
WatsonEngineering Product Approval Approved 1/11/2018
X440-G2-24t-10GE4; X440-G2-
24p-10GE4; X440-G2-24x-
10GE4; X440-G2-48t-10GE4;
X440-G2-48p-10GE4; RPS-500p
NA NA Extreme Networks China
There’s a discussion in the ERB that the product is not ready for use in MTM, somewhere along
those line. Requestor is consulting with SME.
With the SME about this (Marcus) who said he was going to put something together to address
00646 1 CJ Pearce MTM- 1000V Supervisory Switchgear Assembly
Switchgear Assembly manufactured with the following components
32 An Incoming and outgoing tier fitted with:
Schneider NS400N 32395, 1000 V, circuit breakers.
ABB OT200E12, 1000 V, isolator and earthing switches.
Sprecher and Schuh V7-W95, 1000V, connection terminals.
Substations Craig Tooke Grandfather RightsSuspended (Until Further
Notice)11/07/2019
MTM- 1000V Supervisory
Switchgear AssemblyNA NA CJ Pearce Australia Suspended for new installation as advised by Craig Tooke on 11/07/2019
00645 1 LB Foster Protector IV Top of Rail Friction Modifier (Keltrack)The purpose of the system is to control friction to an intermediate level on the railhead in order to reduce rail wear and the onset of corrugations,
reduce wheel noise, and limit the initiation of rolling contact fatigue (RCF) and gauge corner cracking (GCC)
Track &
StructuresNathan Baker Provisional Type Approval Approved 6/11/2019 7880906800 NA NA LB Foster USA
00644 1 Sammode Fitting Lighting fixtures for the MURL Fire & Safety Project Structures Joe Cavric Engineering Product Approval Approved 15/10/2018 NA NA Sammode Australia
Additional costs for maintenance to be included in
Schedule 3 for each location.
Conditions Shall be installed in accordance with manufactures
Restrictions recommendations.
00643 1 Smartlock 400GP Computer Based Interlocking systems and Trackside object controllers . SignalsLee Charnock/Colin
WatersProvisional Type Approval Approved 15/07/2019 15/12/2019 Smartlock 400GP
Alstom Transport/Alstom
Signalling SolutionsFrance
00643 2 Smartlock 400GP Computer Based Interlocking systems and Trackside object controllers . Signals Gail Smith Provisional Type Approval In Progress Smartlock 400GP Alstom Transport/Alstom
Signalling SolutionsFrance
00642 1 Siemens S7-1500 PLC A modular PLC system that can be designed to control many different applications including failsafe applications. OCS
Damien
Watson/Mark
Cole/Joseph Baini
Engineering Product Approval Approved 15/10/2018 Simatic S7-1500 NA NA Siemens Germany
A fully modular or flexible cabling system (provided by either Siemens or Phoenix Contact) must be
used to connect I/O modules to terminal blocks.
14-pin, rather than 50-pin modular cabling must be used when redundancy is required within the
same module.
00641 1 Bypass switch (EATON MPB6Ki)The product will be initially utilised in a UPS rack initially at DSCC containing Eaton UPS and batteries to provide 2hr backup power to Train
Control systems. OCS Mark Cole Engineering Product Approval Approved 15/10/2018 MPB6Ki NA NA Eaton USA
Both the UPS and the Bypass switch must be mounted as low as practicable in the rack and in
close proximity to each other.
Both the UPS and the Bypass switch must be mounted below any battery modules (EBMs).
A Plug/Socket arrangement must be used for the Input (from mains supply) and Output (to
00640 1 Forked Collar Socket Forked Collar Sockets are used to terminate bare aerial copper conductors. Overhead Izy Perona Full Type Approval Approved 15/08/2018 BWC-175 NA NAPreformed Line Products
(PLP)Australia For use on 181mm2 hard-drawn copper catenary wire
00639 1 Oleo Buffer Buffer for rail end stop Track NA Full Type Approval Rejected NA NA Oleo United States of America
00638 1 SPX double compound point layout components SPX components required for a double compound point layout Signals Glenn Miller Provisional Type Approval Approved 6/02/2019 SPX double compound type NA NA SPX England trial only and then go to full type approval
00637 1 SPX brushless Motor Brushless 110V DC motor for use on SPX Rail Systems hydraulic power packs for use with the clamp lock point machine. Signals Glenn Miller Full Type Approval Approved 13/11/2018 NA TBC NA NA SPX England
00636 1 Axis P7214 EncoderFor general use across the OCS Security Network. To provide interfacing to CHP and Lifts for monitoring alarm inputs and recording audio. To
replace current DVTEL encoder that is no longer available. OCS Damien Watson Engineering Product Approval Approved 3/07/2019 P7214 NA NA Axis Sweden
00635 1 Wayguard SEAR II Event Analyser and Recorder System
There are four ways in which SEAR II can be used
Standalone monitors a crossing and accessed only at the crossing
Logging installed at a crossing with ability for remote interrogation but no push alarm
Centralised Logging one or more units installed at a crossing with ability to connect to a central WAMS system for dashboard, interrogation and
Signals Lee Charnock Full Type Approval In Progress NA NA Siemens United States of America
00634 1 Catenary Suspension Insulator and Boom ESP Insulators1500v Overhead Traction Wiring, Hubbell Industries offer a polymeric insulator made from a proprietary material called ESP which is an alloy of
silicone and Ethylene Propylene Diene Monomer Rubber (EPDM). The ESP alloy provides a hardness which is sufficient to resist a bird strike.Overhead Izy Perona Provisional Type Approval Approved 15/08/2018 30/07/2019 NA NA Hubbell United States of America
00633 1 Tortech Isolation TransformerIsolation Transformers are used to ensure separation between local electricity distributor’s MEN earth system and the railway network earthing
systems. These are common across the MTM network where LV supplies are derived for a substation or in some cases railway stations. Substations
George Marulli,
Craig TookeUnder Development Withdrawn NA ISO-3PH-60kVA-IP56 NA NA Tortech Pty Ltd Australia
00632 1 Duratrack SleeperThe Duratrack sleeper is a replacement for mainline low-profile concrete and timber sleepers. The Duratrack sleeper is also suitable for stabling
yards, station pits, elevated rail crossings and will handle poor drainage environments.Track
Gordon Djurdjevic,
Lee Charnock, Jim
Warwick
Provisional Type Approval Approved 26/10/2018 26/04/2020 Gen3 NA NA Integrated Recycling Pty Ltd Australia
00631 1 Secheron Voltage Limiting Device(VLD)
The Alliance is considering the application of Secheron TVP-H product voltage limiting device (VLD) for the application of rail to platform
contactor in accordance with MEST 000002-06 section 15. All elevated station platforms for Caulfield to Dandenong Level Crossings Removal
Project have been earmarked as suitable for this particular application of the VLD.
Substations
Jansen
Mekkaringattu,
James Stevens
Full Type Approval Approved 11/09/2018 SG891020Rxxxxx NA NA Secheron Czech Republic
00630 1Vossloh 1:15, R600 Tangential Turnout, 60kg Rail, Concrete
Bearers
The 1:15 R600 turnout is designed for use on the Victorian broad gauge network, and is designed to meet MTM operational and performance
specifications.
The 1:15 R600 geometry provides an alternative turnout geometry for constrained sites, sitting between the MTM approved 1:9 R250 and 1:15
R800 turnout variants.
TrackMichael Bogan, Jim
ThomsonFull Type Approval Approved 25/11/2019
200.B15940V01 RH
200.B15940V02 LHNA NA Vossloh Australia
00629 1 ENVILINE Energy Storage SystemABB’s ENVILINE Enviline Energy Storage System is a wayside energy management system that converts and stores energy in supercapacitor
based storage unitsSubstations Craig Tooke Full Type Approval In Progress ESS1500 NA NA ABB Australia Pty Ltd Poland
Please refer to L1-CHE-PRO-004 for T.A Procedure
Uncontrolled if printed. Controlled by MTM Eng. Systems (OCE)
Page 5 of 22 [email protected]
Metro Trains Melbourne Engineering Approved Product List As of 20/01/2020 (Updated monthly)
TA
NumberIssue Title/Product Function/Application(s)
Applicable
System(s)SME Approval Type Approval Status
Approval/Rejected
DateExpiry
Withdrawal/Suspension
DateType/Model Number
Hardware
Revision No.
Software Version
No.Manufacturer Place of Manufacture Condition and Service Restrictions
00628 1 Tortech Isolation Transformer 60kVAIsolation Transformers are used to ensure separation between local electricity distributor’s MEN earth system and the railway network earthing
systemsSubstations Craig Tooke Full Type Approval Approved 23/08/2018 ISO-3PH-60kVA-IP56 NA NA Tortech Pty Ltd Australia
00627 1 ERIFLEX Stainless Steel BraidsUtilization of Stainless Steel braids between the earth bridges of the structural elements within the U-Trough piers as a bond connection for
Lightning protection only. Please see attached, Earthing & Bonding drawing detail (item 3).Overhead Bruce Atkinson Under Development Withdrawn 12/11/2018 NA NA ERICO United States of America
00626 1 Junction Rail AS60kg – AS47kg Fabrication junction rail used when joining different sized rails (53kg to 60kg) Track Gordon Djurdjevic Grandfather Rights Approved 13/06/2018
It depends on what’s ordered. It
looks like procurement has
quoted on two types of 53kg /
60kg Junction Rails; both with
NA NAVAE (voestalpine VAE
Railway Systems Pty Ltd)Australia
00624 1 Rail Lock AS 47kg Rail Anchor The ARSC Rail Lock AS 47kg Rail Anchor is a fastener intended for longitudinal restraint of timber sleepered track with 47kg/m rail. Track LPC Provisional Type Approval Approved 10/06/2018 1/06/2019 NA NA A & K Railroad Materials United States of America
• The manufacturer can provide evidence of ongoing compliance with the test requirements of AS
1085.10 at the specified frequencies
• Field inspections are carried out both before and during the summer period (starting 1st of
November). All inspections find that the anchors have:
00624 2 Rail Lock AS 47kg Rail Anchor The ARSC Rail Lock AS 47kg Rail Anchor is a fastener intended for longitudinal restraint of timber sleepered track with 47kg/m rail. Track LPC Provisional Type Approval Approved 1/06/2019 1/09/2019 NA NA A & K Railroad Materials United States of America
• The manufacturer can provide evidence of ongoing compliance with the test requirements of AS
1085.10 at the specified frequencies
• Field inspections are carried out both before and during the summer period (starting 1st of
November). All inspections find that the anchors have:
00623 1 Heat Shrink Cable JointMTM 3.3kV 35mm2 3C Essential Services - to - MTM 650V Old 35mm2 2C
MTM 3.3kV 35mm2 3C Essential Services terminating to M8 stud such as those in TMC transformers and Xiria switchgearSubstations Craig Tooke Engineering Product Approval Approved 5/07/2018
PTC-JK350-2C3C
PTC-TK350-IHT21NA NA Raychem Germany
• In line joints shall be used with Type Approved 35 sq. mm cable as per L1-CHE-SPE-148 and
Type Approved 35 sq. mm 2 core copper 650 volt cable
• All in line joints shall be installed in accordance with L1-CHE-SPE-070
• Joints shall only be made where the system voltage does not exceed 650V
00622 1 Phoenix Contact QUINT-PS/24DC/48DC/5 This DC-DC converter will be used to power 48vDC equipment, such as CCTV network switches which are supplied from battery-backed 24vDC
sources (24v battery banks or 24v UPS).OCS Mark Cole Engineering Product Approval Approved 6/06/2018 QUINT-PS/24DC/48DC/5 NA NA Phoenix Contact China Output voltage setpoint to be documented during commissioning/installation.
00621 1 FLIR FB-ID Thermal CameraFor use across the OCS Security Network for intrusion detection, such as in tunnels and sidings with no effect on lighting conditions. To work
in conjunction with other detection systems and existing CCTV cameras to improve system security and safety.OCS Damien Watson Engineering Product Approval Approved 12/06/2018 FB-349-ID NA NA FLIR Estonia
Camera to be mounted with FLIR CB-WLBX-62 to allow mounting to any wall or ceiling or FLIR CB-
PLBX-62 if mounting on a pole. These junction boxes allow for conduit entry and secure
concealment of cables.
00620 1 Safezone Visual In-Track Alert (VITAL)
This system is intended for use in a start against stop SPAD mitigation trial project aimed at reducing the number of SPADs that occur because
of drivers starting against a signal at stop.
This system is not intended for use in any safety/service critical applications, it is indication only and non-authoritative.
Signals Lee Charnock Full Type Approval Rejected N/A NA NA Inventis Technology Australia
00619 1 Train Wash
The Train Wash is located within a purpose built building at the south west corner of the Pakenham East depot, located between the arrival and
departure roads, enabling washing to occur upon entry or exit of the depot. The system is designed to automatically operate as the train
approaches from either direction. Radio Frequency Identification will be utilised to detect rolling stock on approach and activate a “wash mode”
on board the train to enable a driver to automatically drive through the facility.
Multiple TBC On Hold Withdrawn NA NA NA NAOtto Christ AG, Working
Water, Wilcomatic Switzerland & United Kingdom
00618 1 BAMS
HCMT - Bearing Acoustic Monitoring System (BAMS)
The solar powered, 4G system is to be installed on the down mainline between Pakenham station and Pakenham East Depot, the HCMT must
be travelling above 40km/h.
The BAMS is one part of the Automatic Wheel Condition Monitoring System (AWCMS). Track IQ’s RailBAM is a Bearing Acoustic Monitoring
Track &
Structures
Andrew
Robinson,David
McKinlay,Mark
Cole, Ian Roulstone
Under Development In Progress Track IQ RailBAM NA NA TrackIQ Australia
00617 1 TrackLink 3 TagThe Tag transmits and reflects an encoded signal back to the reader which decodes the signal for application specific functions:
Correct Side Door Enable (CSDE), Door Selective Door Opening (SDO).Signals
Andrew
Robinson,David
McKinlay,Mark
Cole, Ian Roulstone
Engineering Product Approval Approved 21/06/2019 HSD2300/041 NA NA Sella Controls United Kingdom
00616 1 Micro GlassMicroGlass is a sprayable non slip coating that is environmentally friendly, low VOC coating designed to provide a durable and anti-slip coating
for virtually any hard exterior or industrial flooring (concrete, steel, timber, bitumen and ceramic tiles). Track
John Dauth, Joe
CavricEngineering Product Approval Approved 25/06/2018 WO-MG-GLOW NA NA Wayout/CRG Australia
• Slip resistance rating chosen needs to be assessed for its application and site. (P3 – P5 available )
• Micro Glass - Engineering Product must be installed minimum of 900 mm from the yellow line and
offset from TGSI’s by 200mm minimum.
• Schedule 3 cost to be provided to maintain photoluminescent wayout strip to the required 5 year
00615 1Metrospec 46H: 46” 1500Nit IP65 Passenger Information
Display
The Metrospec 46” PID is an LCD panel allowing for more features such as sunlight viewable, automatic dimming and anti-vandalism features
and provide greater information for customers.
The Metrospec 46” PID is a replacement product for 47” PID, as 47” PID is obsolete.
The LCD panels are IP65 rated and are driven by a PC situated within the Panel.
OCSMark Cole, Joseph
BainiUnder Development Withdrawn NA Metrospec H46 NA NA Metrospec Australia
00614 1 AVEPRO Shock TrackAvePro Shock Track is a professional electrified shock track designed to deter all pest birds from ledges, parapets, beams, roofs and numerous
other architectural features. AvePro is a strong deterrent to birds and is the least visible product of all bird deterrent systems.Track
Louise Knapp, Neal
MastersEngineering Product Approval Approved 3/07/2018 N/A NA NA Bird Barrier America Inc USA
The route of the shock track system shall be documented on Architectural roof plans and Building
Services drawings – Electrical.
The track shall be installed using both mechanical and adhesive fixing.
Power supply to bird shock system shall be taken from DBs serving non critical loads within the
00613 1 veloSTRAIL
VeloStrail is a rubber panel pedestrian crossing system that eliminates the flangeway gap with a replaceable rubber component. The system is
similar to the MTM type approved (under Grandfather Rights) PedeStrail Pedestrian Crossing System with the main difference being that there
is a compressible, interchangeable flange-way element within the level crossing panel that fills the gap between the rail profile and level crossing
surface and prevents entrapment in the flange-way of cyclists, wheelchairs and other wheels.
Track Gordon Djurdjevic Provisional Type Approval Approved 18/07/2018 18/07/2019 NA NAKraiburg Strail GmBH & Co
KGGermany
• The product shall only be used for pedestrian level crossings.
• Panels shall be installed as per the manufacturer’s instructions, any relevant site specific design
drawings, MTM standard drawing STD_R0022 and L1-CHE-STD-034.
• As a part of the trial, MTM Engineering – Track and Structures shall assess the condition of the
00612 1 MRD Relay Doc Miniature relay test device -non safety critical device Signals Glenn Miller Full Type Approval Approved 19/06/2018 MRD Relay Doc NA NA MRD australia
Table 1. Conditions of Use:-
1) The performance requirements that are required to be input to the RelayDoc to test new relays
against, shall only be set by a Signal Maintenance Engineer or Supervisor, Signal Maintenance
Officer in Charge or Signal Maintenance Relay Technician.
2) Only approved versions of software shall be loaded onto computers to control the tester.
3) Units and components shall only be transported in a shock resistant case (provided with the
RelayDoc).
4) Users of the RelayDoc should be trained and competent in the use of the RelayDoc.
5) Testing of relays shall only be carried out at the relay’s normal operating temperature
6) The RelayDoc shall be calibrated before use of the unit via the self-calibration block.
7) The RelayDoc shall only to be repaired by the Manufacturer (MRD)
8) The RelayDoc shall be used in accordance to the manufacturer’s user manual.
00611 1 Grau Battery Charger Power SupplyTo provide a reliable 24V DC supply to the WESTRACE, Axle counters and other Communications equipment on MTM network for Signalling
applications.Signals Lee Charnock Full Type Approval Approved 19/07/2018 N/A
Battery Charger Power Supply 24
v DC 10 Amp -250watt -250 LGB
230 M24
Hardware-NA, Software NA
N/A N/A Grau Germany
Table 1. Conditions of Use:-
1) When used as a battery charger, consideration for using a product that automatically disconnects
the battery from over discharging shall be mode before using the Grau product.
2) Where the Grau power supply is used in equipment location cases, they shall only be MTM
approved double skin type.
3) The location cases, where practical, shall be orientated with respect to the sun to reduce the
heating effects of direct Infra-red Radiation.
4) The system design shall include RAMS analysis to determine suitable backup power durations
and the size of batteries required. This shall consider areas not covered under the MTM Essential
Services Distribution System (ESDS) supplied areas.
5) Power supplies used for Vital and Operation-critical equipment must be provided in a high-
availability, redundant configuration. Waivers will be considered for project specific applications,
where it can be demonstrated that the applicable availability requirements have been satisfied and
subject to demonstrating how single point of failures have been minimised a So Far as is
Reasonably Practicable.
6) For maintainability, the design shall use the output failure alarm contact provided in the Grau
power supply to generate an alarm in the Maintenance Support System.
7) For maintainability, all designs shall detect failures of the 110V AC busbar and also the supply
that is directly powering the Grau battery charger and generate an alarm in the Maintenance
Support System.
8) That all alarms shall be configured such that the “ON” contact is a normally “closed” contact.
00610 1ART 3000VDC / 4000A Three Position Wall and Mast
Mounted Switches
The switches are direct replacements for existing ART switches with an increased continuous current rating of 4000 Amps. The existing ART
switches are only rated at 1500 Amps. The new switches perform the same functions as the existing switches but include a changeover third
postion for applying short circuit to the conductors. The proposed switches have the same mounting arrangement as the existing switches and
will be able to be retro fitted to existing locations. In addition the switch handle mechanism is unchanged simplifying the change over process.
The new switches do not require additional maintenance procedure.
Overhead Izy Perona Full Type Approval Approved 16/07/2018 XP388.2D00 N/A N/A Australian Rail Technology Australia
00609 1 Nexans 6.6kV Cables Conductor 3.8/6.6kV XLPE InsulatedElectrical
NetworksCraig Tooke Under Development Registered
XHNA30RD001,
XHHP28RD001,XHZA30RD001N/A N/A Nexans Olex China
00608 1 Grundfos Ground water pump Track Liam PC Engineering Product Approval Approved 24/04/2018 SQE 1-35N - 96160436 N/A N/A Grundfos Mexico
An Operation and Maintenance Manual for the ground water drainage system shall be provided.
The Manual shall detail equivalent products that are freely available from alternative suppliers for all
components including pipework, pumps, level transmitters, PLC etc.
The design of the product shall be as per EN 1.4401 / AISI 316 stainless steel grade specification.
00607 1 Tracktex Tracktex is to be applied in areas where there have been documented erosion pumping of the formation and it needs to be addressed. Track Gordon Djurdjevic Engineering Product Approval Approved 13/04/2018 N/A N/A Geofabrics Australia
1. Tracktex"v' shall be installed as per the Geofabrics Installation Guide.
2. TracktexTM shall be protected by a minimum 150mm of ballast prior to any construction traffic is
allowed to run over it.
3. If there is any change in Manufacturer, the Product Approval shall be reviewed by Engineering.
00606 1 3.8/6.6kv Single Core 500mm26.6kV power cable, 1 core 500mm2, aluminium conductor, XLPE insulation, Copper wire screen withstand 13.5kA, PVC inner sheath and
HDPE outer sheathSubstations Craig Tooke Full Type Approval In Progress 13/11/2019
AL/XLPE/CWS
(13.5kA)/PVC/HDPE 3.8/6.6kV
1x500
N/A N/AJiangsu Zhongtian
Technology Co., Ltd China
00605 1 SIMATIC ET200M I/O System The modular I/O station for the control cabinet with high density-channel applications. OCS Mark Cole Engineering Product Approval Approved 29/05/2018 ET200M N/A N/A Siemens GermanyShall be deployed in a slave configuration only.
Communication method shall be PROFINENT rather PROFIBUS.
00604 13.3kV small inline single core termination with mechanical
linksMedium and low voltage terminations and joints for traction and 581V Anode circuits (incorrect application)
Electrical
NetworksCraig Tooke Full Type Approval Registered H3i1XCOMMT024 N/A N/A Hongshang China
00603 1Cast Resin Joint for 35mm 2 core-35mm sq 6.6kV cable(
650V Voltage class)Joining kits for Signal Power Cables Substations Craig Tooke Full Type Approval Registered
GTACOMMT018 Cast Resin
Joint for 35mm 2 core-35mm sq
6.6kV cable( 650V Voltage class)
N/A N/A Hongshang China
00602 1Cast Resin Joint for 35mmsq-35mmsq 6.6kV cable 2.2Kv
(VoltageClass)Joining kits for Signal Power Cables Substations Craig Tooke Engineering Product Approval Approved 29/05/2018
GTACOM6MT017 Cast Resin
Joint for 35mmsq-35mmsq 6.6kV
cable 2.2Kv (VoltageClass)N/A N/A Hongshang China
• In line joints to be used with Type Approved 35 sq. mm cable as per L1-CHE-SPE-228
• All in line joints shall be installed in accordance with L1-CHE-SPE-070
00601 1 TVP-H product voltage limiting device (VLD) Rail to earth voltage monitoring device. SubstationsJansen
MekkaringattuFull Type Approval Registered SG891020Rxxxxx N/A N/A Secheron Czech Republic
00600 1 Zinfra 22kV Cable For underground 22kV applications Substations Craig Tooke Engineering Product Approval Approved 19/03/2018AL/XLPE/CWS(13.1kA)/PVC/HD
PE 12.7/22kV 3x185mm2N/A N/A Zinfra China
00599 1Cast Resin Joint for 16mm sq SWA 2.2kV-35mm sq 6.6Kv
cable (Voltage class 2.2kV)Joining kits for Signal Power Cables Substations Craig Tooke Engineering Product Approval Approved 29/05/2018
GTACOM6MT016 Cast Resin
Joint for 16mm sq SWA 2.2kV-
35mm sq 6.6Kv cable (Voltage
class 2.2kV)
N/A N/A Hongshang China
• In line joints to be used with Type Approved 35 sq. mm cable as per L1-CHE-SPE-148 and Type
Approved 16 sq. mm 2 core copper cable
• All in line joints shall be installed in accordance with L1-CHE-SPE-070
• Joints to only be made where the system voltage does not exceed 2.2 kV
00598 1 SIMATIC WinCC Open Architecture MURL CMS Replacement Project OCS Niels Endres Full Type Approval Approved 24/05/2018 N/A N/A 3.15 ETM AustriaCyber security implications related to network and software configuration shall be a specific
component of the risk assessment carried out under the MoC/EC process.
00597 1 Sicut composite railway sleepersComposite sleepers can be used in all aspects of railway infrastructure such as Mainline, Turn-outs, spot replacements, ballasted and ballast-
less bridges, tunnels, over-passes, light rail to heavy haulage applications etc.Track Timothy Powell Provisional Type Approval Approved 10/05/2018 10/05/2020 N/A N/A N/A Sicut
UK (Plans to manufacture in
Australia post-trial)
1. Rail shall be fastened to the Sicut® Composite Railway Sleeper with Pandrol plates and type
approved cold forge screw spikes, as per installation guide and SDS.
2. Composite sleepers shall be suitable for trial at the following speeds and axle loadings:
• 19T @ 160 km/h.
00596 1 3.3kV small inline single core Joint with mechanical links Medium and low voltage terminations and joints for traction and 581V Anode circuits (incorrect application)Electrical
NetworksCraig Tooke Full Type Approval Registered H3J1XMT020 N/A N/A Hongshang China
00595 1Phoenix Contact 24 volt DC 20AMP Power Supply and UPS
module.Power Supply/Charger to provide 24 volt DC up to 20 amp for electronic based equipment Signals
Glenn Miller/Niels
EndresFull Type Approval Rejected
QUINT-PS/1AC/24DC/20
QUINT-UPS/24v DC/20N/A N/A Phoenix Contact GMBH Germany
Please refer to L1-CHE-PRO-004 for T.A Procedure
Uncontrolled if printed. Controlled by MTM Eng. Systems (OCE)
Page 6 of 22 [email protected]
Metro Trains Melbourne Engineering Approved Product List As of 20/01/2020 (Updated monthly)
TA
NumberIssue Title/Product Function/Application(s)
Applicable
System(s)SME Approval Type Approval Status
Approval/Rejected
DateExpiry
Withdrawal/Suspension
DateType/Model Number
Hardware
Revision No.
Software Version
No.Manufacturer Place of Manufacture Condition and Service Restrictions
00594 1 ECOTRAX composite sleepers Road crossing sleepers, tunnel sleepers, turnout & switch bearers, mainline sleepers, ballasted open deck bridge sleepers. Track Nathan Baker Provisional Type Approval In Progress N/A N/A N/A Axion Structural Innovations USA
00593 1 Solacoat Water Based Primer and Quick Dry Topcoat Solacoat Topcoat and Primer is to be used to paint the rail and reduce rail temperature. Track Timothy Powell Provisional Type Approval Approved 11/05/2018 11/05/2019 N/A N/A N/ACoolshield International Pty
LtdAustralia
1. A procedure shall be prepared by the Infrastructure Delivery track department detailing
application requirements for painting rail. Staff shall be trained in correct application of Solacoat to
rail.
2. All marks on the rail including welding, stressing and RFD records shall be transposed post-
application of Solacoat and recorded for future reference.
3. Solacoat shall be carefully applied and/or spray nozzles adjusted so paint is NOT applied to the
running surface or gauge face of the rail. Any overspray shall be removed using the appropriate
paint remover.
00593 2 Solacoat Water Based Primer and Quick Dry Topcoat Solacoat Topcoat and Primer is to be used to paint the rail and reduce rail temperature. Track Nathan Baker Full Type Approval Approved 6/05/2019 NA N/A N/A N/ACoolshield International Pty
LtdAustralia
Solacoat shall be carefully applied in accordance with L2-TRK-PRO-059 Applying Paint Type
Temperature Moderator to Rail.
00592 1The S600 network time server is purpose built to deliver
hardware based Network Time Protocol (NTP) timestamps
The S600 network time server is purpose built to deliver hardware based Network Time Protocol (NTP) timestamps. It provides high accuracy
and security and it is easy to use. OCS Damien Watson Engineering Product Approval Approved 9/04/2018
SyncServer S600 /090-15200-
601N/A N/A Microsemi USA
1. Shall be ordered with dual power supplies
2. Shall be ordered with either the OCXO or Rubidium oscillator upgrade
NB – the Rubidium option has a higher accuracy rating but does lower the operating temperature
range which needs to be considered during design.
00591 1 Gauge Tie BarGauge tie bars can be used to correct or maintain track gauge where required by competent Track Delivery staff. Gauge tie bars are only to be
used in conjunction with existing processes of managing defects. Gauge tie bars are not to be solely relied on to maintain track condition.Track Timothy Powell Provisional Type Approval Approved 26/04/2018 26/04/2019 1121465 N/A N/A
Melvelle Equipment Corp.
Pty LtdAustralia
1. Insulated Gauge Tie Bars shall be installed in accordance with Manufacturer’s instructions, refer
MANUAL-112-GTB.
2. Insulated Gauge Tie Bars shall only be installed by trained and competent track personnel.
3. Rail Corridor surrounding Insulated Gauge Tie Bars shall be free of scrap metal (dogspikes, clips
00591 2 Gauge Tie BarGauge tie bars can be used to correct or maintain track gauge where required by competent Track Delivery staff. Gauge tie bars are only to be
used in conjunction with existing processes of managing defects. Gauge tie bars are not to be solely relied on to maintain track condition.Track Hassan Elaina Provisional Type Approval Approved 6/05/2019 6/11/2019 1121465 N/A N/A
Melvelle Equipment Corp.
Pty LtdAustralia
1. Insulated Gauge Tie Bars shall be installed in accordance with Manufacturer’s instructions, refer
MANUAL-112-GTB.
2. Insulated Gauge Tie Bars shall only be installed by trained and competent track personnel.
3. Rail Corridor surrounding Insulated Gauge Tie Bars shall be free of scrap metal (dogspikes, clips
00590 1 1RU Dell KVM - LED monitor & Mounting bracket Accessories OCS Mark Cole Grandfather Rights Approved 26/02/2018
Dell DKMMLED185-001
Dell DRMK-77N/A N/A
00589 1 2x8ch Single Core Mux Side 'A&B' CWDM Mux/DeMux OCS Mark Cole Grandfather Rights Approved 26/02/2018MD-8CH-1RU-CWDM-1310-
LCSX-A&BN/A N/A
00588 1 Outdoor Sound Column Speakers 10W (slimline) PA System OCS Mark Cole Grandfather Rights Approved 26/02/2018 Australian Monitor CS210 N/A N/A
00587 1 Ambient Noise Control Module - TOA PA System OCS Mark Cole Grandfather Rights Approved 26/02/2018 TOA AN001T N/A N/A
00586 1 Dual Line Output Module for 9000 Series - TOA PA System OCS Mark Cole Grandfather Rights Approved 26/02/2018 TOA T001T N/A N/A
00585 1 Dual Mic/Line Input Module for 9000 Series - TOA PA System OCS Mark Cole Grandfather Rights Approved 26/02/2018 TOA D001T N/A N/A
00584 1Modular Powered 8x8 Matrix Mixer with 2 x 500W 100V line
outputs (incl. 1 x D001T) - TOAPA System OCS Mark Cole Grandfather Rights Approved 26/02/2018 TOA A9500D2 N/A N/A
00583 1 Flat Panel PID Display PC - FitPC4 Pass Info Displays & Clocks OCS Mark Cole Grandfather Rights Approved 26/02/2018
FitPC4 Pro Barebone. No
HDD/SSD, No Wifi, 4GB RAM,
Hardened VESA mounting
bracket for fit-PC3/4/IPC
N/A N/A
00582 1 Flat Panel 47" LCD PID – Double Sided Pass Info Displays & Clocks OCS Mark Cole Grandfather Rights Approved 26/02/2018MS-47-2000 (Double Sided)
Brackets ordered seprately.N/A N/A
00581 1 Flat Panel 47" LCD PID – Single Sided Pass Info Displays & Clocks OCS Mark Cole Grandfather Rights Approved 26/02/2018MS-47-2000 (Single Sided)
Brackets ordered seprately.N/A N/A Use for maintenance purposes only as advised by Mark Cole 22/02/2019
00580 1 Emergency Glass Break Release White DPDT - KAC Security & Access Control OCS Mark Cole Grandfather Rights Approved 26/02/2018 MCP4A-WOOOSG-HO69-OI N/A N/A
00579 1 Stainless Steel Duress button Security & Access Control OCS Mark Cole Grandfather Rights Approved 26/02/2018 PADP2 N/A N/A
00578 1 Wide Gap Reed Switch - Sentrol Security & Access Control OCS Mark Cole Grandfather Rights Approved 26/02/2018 2505A N/A N/A
00577 1 LCD Monitor SPOT OCS Mark Cole Grandfather Rights Approved 26/02/2018
PACOM 215LED-MET-NG
(Modified to suit SPOT
functionality)
N/A N/A
00576 1Mounting bracket – J mount bracket for mounting EH3512 to
buildingCCTV OCS Mark Cole Grandfather Rights Approved 26/02/2018 EM1900U N/A N/A
00575 1 Expansion Module - 2 x Stack Ports Site Master LAN / ELECTROL SCADA Switch options OCS Mark Cole Grandfather Rights Approved 26/02/2018
Summit X460-G2 VIM-2ss -
Optional Virtual Interface Module
(Part No. 16713)
N/A N/A
00574 1 Expansion Module - 2 x SFP+ Site Master LAN / ELECTROL SCADA Switch options (Summit X460-G2 VIM-2x - Optional Virtual Interface Module (Part No. 16711)) OCS Mark Cole Grandfather Rights Approved 26/02/2018
Summit X460-G2 VIM-2x -
Optional Virtual Interface Module
(Part No. 16711)
N/A N/A
00573 1 Fan module Site Master LAN / ELECTROL SCADA Switch options OCS Mark Cole Grandfather Rights Approved 26/02/2018
Summit Fan module FB for
Summit X460-G2 Series
Switches (Part No. 10945)
N/A N/A
00572 1 UPS ELECTROL SCADA UPS/Power OCS Mark Cole Grandfather Rights Approved 26/02/2018 Eaton 5P 1150 N/A N/A
00571 1 UPS ELECTROL SCADA UPS/Power OCS Mark Cole Grandfather Rights Approved 26/02/2018 Eaton Evolution 1150 N/A N/A
00570 1 APC Automatic Transfer Switch (ATS) ELECTROL SCADA UPS/Power OCS Mark Cole Grandfather Rights Approved 26/02/2018 AP7723, AP7721 N/A N/ATo be used for reactive/corrective maintnence only
Not be used in new installations or purchased.
00569 1 Cisco ASA5505 Firewall OCS Mark Cole Grandfather Rights Approved 26/02/2018 Cisco-ASA5505 N/A N/A
00568 1 1-Port Gigabit Ethernet SFP Mini-PIM Firewall OCS Mark Cole Grandfather Rights Approved 26/02/2018 SFP Mini-PIM N/A N/A
00567 1 Juniper SRX240 Firewall OCS Mark Cole Grandfather Rights Approved 26/02/2018 SRX240-H2 N/A N/A Requires ATS to provide redundant power
00566 1 Netcomm M2M Router 4G/3G Router OCS Mark Cole Grandfather Rights Approved 26/02/2018 NTC-140W-02 N/A N/A
00565 1 RuggedComm RX1400 RX1400 Field Switch OCS Mark Cole Grandfather Rights Approved 26/02/2018 6GK6014-0A N/A N/A
00564 1 3G Module RX1500 Field Switch OCS Mark Cole Grandfather Rights Approved 26/02/2018 W11 N/A N/A 1x GSM/EDGE/HSPA
00563 1 1000-SFP Module RX1500 Field Switch OCS Mark Cole Grandfather Rights Approved 26/02/2018 FG50 N/A N/A 2x 1000LX SFP Blank (no optical transceiver)
00562 1 100-tx Module RX1500 Field Switch OCS Mark Cole Grandfather Rights Approved 26/02/2018 6TX01 N/A N/A 6x 10/100TX RJ45
00561 1 10-FL Module RX1500 Field Switch OCS Mark Cole Grandfather Rights Approved 26/02/2018 FL01 N/A N/A 3x 10FL Multimode 850nm ST 2km
00560 1 High-Range Power Module RX1500 Field Switch OCS Mark Cole Grandfather Rights Approved 26/02/2018 HI N/A N/A 88-300 VDC or 85-264VAC, screw terminal block
00559 1 48vDC Power Module RX1500 Field Switch OCS Mark Cole Grandfather Rights Approved 26/02/2018 48 N/A N/A 48VDC (36-72VDC), screw terminal block
00558 1 RuggedComm RX1500 RX1500 Field Switch OCS Mark Cole Grandfather Rights Approved 26/02/2018 RX1500-L3 N/A N/A RX1500 8 Gigabit Layer 3 w/ 4 LM slots and 2 PM slot
00557 1 Basic Layer-2 ethernet switch Non-Core Network Switch OCS Mark Cole Grandfather Rights Approved 26/02/2018 Summit X430-24p N/A N/ATo be used for reactive/corrective maintnence only
Not be used in new installations or purchased.
Please refer to L1-CHE-PRO-004 for T.A Procedure
Uncontrolled if printed. Controlled by MTM Eng. Systems (OCE)
Page 7 of 22 [email protected]
Metro Trains Melbourne Engineering Approved Product List As of 20/01/2020 (Updated monthly)
TA
NumberIssue Title/Product Function/Application(s)
Applicable
System(s)SME Approval Type Approval Status
Approval/Rejected
DateExpiry
Withdrawal/Suspension
DateType/Model Number
Hardware
Revision No.
Software Version
No.Manufacturer Place of Manufacture Condition and Service Restrictions
00556 1 2 x SFP+ Option Card Core Network Switch OCS Mark Cole Grandfather Rights Approved 26/02/2018 XGM3-2SF (Part No. 16117) N/A N/ATo be used for reactive/corrective maintnence only
Not be used in new installations or purchased.
00555 1 Redundant, Hot pluggable 240V PSU, Extreme Networks Core Network Switch OCS Mark Cole Grandfather Rights Approved 26/02/2018Summit x460 AC PSU (Part No.
10930)N/A N/A
To be used for reactive/corrective maintnence only
Not be used in new installations or purchased.
00554 1Base Switch, 240V powered must have redundant power
optionCore Network Switch OCS Mark Cole Grandfather Rights Approved 26/02/2018
Summit x460-24t/x/p (Part No.
16401)N/A N/A
To be used for reactive/corrective maintnence only
Not be used in new installations or purchased.
00553 1 Small Loop AFILS Amplifiers OCS Mark Cole Grandfather Rights Approved 26/02/2018
LIC XL-150 (covers up to 150m2)
[requires external 50:1
transformer for input from 100V
line]
N/A N/A
00552 1 Medium Loop AFILS Amplifiers OCS Mark Cole Grandfather Rights Approved 26/02/2018
Bosch PLN-1LA10 (covers up to
600m2) [has inbuilt screw
terminal 100V balanced line
input]
N/A N/A
00551 1 Large Loop AFILS Amplifiers OCS Mark Cole Grandfather Rights Approved 26/02/2018
LIC XL-2000 (covers up to
2000m2) [requires external 50:1
transformer for input from 100V
line]
N/A N/A
00550 1 Techniplan Remote PA Access Modules PA System OCS Mark Cole Grandfather Rights Approved 26/02/2018
System Interface Module (SIM)
Line Isolation Module (LIM)
Tone Detect Module (TDM)
Teleswitch Module
N/A N/A
To be used for reactive/corrective maintnence only
Not be used in new installations or purchased.
Techniplan Systems & Components Can Only be Sourced From MTM Infrastructure Operations -
OCS - PIDS
00549 1 Extended Zone Speaker Switchbox PA System OCS Mark Cole Grandfather Rights Approved 26/02/2018 Refer to Drawing SS00/615 N/A N/A
To be used for reactive/corrective maintnence only
Not be used in new installations or purchased.
Custom fabricated
00548 1 UHF Antenna for cordless mic receiver PA System OCS Mark Cole Grandfather Rights Approved 26/02/2018 TOA YW4500 N/A N/A
00547 1Hand held UHF cordless microphone, configurable for 64
channelsPA System OCS Mark Cole Grandfather Rights Approved 26/02/2018 TOA WM5265FO1AS N/A N/A
00546 1UHF cordless microphone receiver configurable to one of 64
Channels, with antenna distribution for PA System OCS Mark Cole Grandfather Rights Approved 26/02/2018 TOA WT5800FO1AS N/A N/A
00545 1Free standing desktop microphone with PTT and zone
selectionPA System OCS Mark Cole Grandfather Rights Approved 26/02/2018 Redback A4585 N/A N/A
00544 1 Free standing desktop microphone with PTT PA System OCS Mark Cole Grandfather Rights Approved 26/02/2018 Redback A2086 N/A N/ATo be used for reactive/corrective maintnence only
Not be used in new installations or purchased.
00543 1 Indoor Flush Ceiling Speakers PA System OCS Mark Cole Grandfather Rights Approved 26/02/2018 TOA PC-1869 N/A N/A
00542 1 Outdoor Under Canopy Speakers or indoor (surface bracket) PA System OCS Mark Cole Grandfather Rights Approved 26/02/2018 TOA PJ-100W N/A N/A
00541 1Outdoor Speakers 6W (poles on new platforms, also under
canopy)PA System OCS Mark Cole Grandfather Rights Approved 26/02/2018 TOA CS-64 N/A N/A
00540 1
Outdoor Horn Speakers 15W (only for coverage extension of
existing SC-615M horn speaker systems, not for use on new
or fully redeveloped platforms)
PA System OCS Mark Cole Grandfather Rights Approved 26/02/2018 TOA SC-615M N/A N/A
00539 1 Crown Power Amplifier PA System OCS Mark Cole Grandfather Rights Approved 26/02/2018 DCI Analogue 2-1250 N/A N/A Approved for use at Flinders Street Station Only
00538 1 Sound Web London Signal Processor PA System OCS Mark Cole Grandfather Rights Approved 26/02/2018 BLU-100 N/A N/A Approved for use at Flinders Street Station Only
00537 1 8 Channel Mixer Preamplifier PA System OCS Mark Cole Grandfather Rights Approved 26/02/2018 TOA M-900MK2 N/A N/ATo be used for reactive/corrective maintnence only
Not be used in new installations or purchased.
00536 1
Plug-in modules for Power Amplifier
- Balanced Line / Unbalanced Mic Input (10kΏ) with Vox and
dual mute bus support
PA System OCS Mark Cole Grandfather Rights Approved 26/02/2018 TOA ML-11T N/A N/ATo be used for reactive/corrective maintnence only
Not be used in new installations or purchased.
00535 1 Modular Amplifier 340W PA System OCS Mark Cole Grandfather Rights Approved 26/02/2018 TOA DA-250D N/A N/ATo be used for reactive/corrective maintnence only
Not be used in new installations or purchased.
00534 1 Modular Amplifier 680W PA System OCS Mark Cole Grandfather Rights Approved 26/02/2018 TOA DA-250F N/A N/ATo be used for reactive/corrective maintnence only
Not be used in new installations or purchased.
00533 1 Intercom unit - Dallas Delta CHP OCS Mark Cole Grandfather Rights Approved 26/02/2018 SentryBK10-LST N/A N/A
00532 1 CHP stankess steel surface mount shroud CHP OCS Mark Cole Grandfather Rights Approved 26/02/2018ENCSSH ENC 270x130
Horizontal SSN/A N/A
00531 1 CHP Intercom Mounting Panel CHP OCS Mark Cole Grandfather Rights Approved 26/02/2018 Custom manufactured by Metlink N/A N/A
00530 1 CHP Phone Assembly Analogue Red & Green Button CHP OCS Mark Cole Grandfather Rights Approved 26/02/2018 Century DCOM2BHPTCAGC N/A N/A
00529 1 CHP Phone Assembly Analogue Red Button CHP OCS Mark Cole Grandfather Rights Approved 26/02/2018 Century DCOM1BHPTCAGC N/A N/A
00528 1 Outdoor VOIP intercom – 1 button horizontal VOIP Intercom OCS Mark Cole Grandfather Rights Approved 26/02/2018 Dallas Delta GUARDMK3VOIP1H N/A N/A
00527 1 Outdoor VOIP intercom – 1 button vertical VOIP Intercom OCS Mark Cole Grandfather Rights Approved 26/02/2018 Dallas Delta GUARDMK2VOIP1V N/A N/A
00526 1 Desktop VOIP intercom (phone) VOIP Intercom OCS Mark Cole Grandfather Rights Approved 26/02/2018 Yealink SIP-T28PG N/A N/A
00525 1 VOIP PBX (Server) - 32 VOIP intercoms/phones VOIP Intercom OCS Mark Cole Grandfather Rights Approved 26/02/2018 Epygi Quadro M8L N/A N/A
00524 1 Expand Quadro 2x to 16 intercoms/phones VOIP Intercom OCS Mark Cole Grandfather Rights Approved 26/02/2018Quadro2x IP Phone Expansion
KeyN/A N/A
00523 1 VOIP PBX (Server) - 8 VOIP intercoms/phones VOIP Intercom OCS Mark Cole Grandfather Rights Approved 26/02/2018 Epygi Quadro 2x N/A N/A
00522 1 Signal Box Digital Clock LED 50mm (single or double sided) Pass Info Displays & Clocks OCS Mark Cole Grandfather Rights Approved 26/02/2018AD Engineering AD312-50 NTP
Clock & optional GPS recieverN/A N/A
00521 1 Platform Digital Clock LED 100mm (single or double sided) Pass Info Displays & Clocks OCS Mark Cole Grandfather Rights Approved 26/02/2018AD Engineering AD312-150 NTP
Clock & optional GPS recieverN/A N/A
00520 1 PIDS Display LED – 4 line Double Sided Pass Info Displays & Clocks OCS Mark Cole Grandfather Rights Approved 26/02/2018Display Logic 4 Line Double
Sided 40 Character Per LineN/A N/A
To be used for reactive/corrective maintnence only
Not be used in new installations or purchased.
00519 1 PIDS Display LED – 4 line Single Sided Pass Info Displays & Clocks OCS Mark Cole Grandfather Rights Approved 26/02/2018Display Logic 4 Line Single Sided
40 Character Per LineN/A N/A
To be used for reactive/corrective maintnence only
Not be used in new installations or purchased.
00518 1 PIDS Display LED – 2 line Double Sided Pass Info Displays & Clocks OCS Mark Cole Grandfather Rights Approved 26/02/2018Display Logic 2 Line Double
Sided 20 CharacterN/A N/A
To be used for reactive/corrective maintnence only
Not be used in new installations or purchased.
00517 1 PIDS Display LED – 2 line Single Sided Pass Info Displays & Clocks OCS Mark Cole Grandfather Rights Approved 26/02/2018Display Logic 2 Line Single Sided
Character Per LineN/A N/A
To be used for reactive/corrective maintnence only
Not be used in new installations or purchased.
00516 1 Smoke Detector Security & Access Control OCS Mark Cole Grandfather Rights Approved 26/02/2018 ESL449CSTN-AA N/A N/A
Please refer to L1-CHE-PRO-004 for T.A Procedure
Uncontrolled if printed. Controlled by MTM Eng. Systems (OCE)
Page 8 of 22 [email protected]
Metro Trains Melbourne Engineering Approved Product List As of 20/01/2020 (Updated monthly)
TA
NumberIssue Title/Product Function/Application(s)
Applicable
System(s)SME Approval Type Approval Status
Approval/Rejected
DateExpiry
Withdrawal/Suspension
DateType/Model Number
Hardware
Revision No.
Software Version
No.Manufacturer Place of Manufacture Condition and Service Restrictions
00515 1 Aritech PIR Detector Security & Access Control OCS Mark Cole Grandfather Rights Approved 26/02/2018 EV669 N/A N/A
00514 1 Roller Shutter Door Reed Switch – Sentrol Security & Access Control OCS Mark Cole Grandfather Rights Approved 26/02/2018 2302A N/A N/A
00513 1 Heavy Duty Reed Switch – Sentrol Security & Access Control OCS Mark Cole Grandfather Rights Approved 26/02/2018 2202A N/A N/A
00512 1Triple Bias Door Reed Switch for Double leaf Doors with
Maglock- SentrolSecurity & Access Control OCS Mark Cole Grandfather Rights Approved 26/02/2018 2767-L N/A N/A
00511 1 Triple Bias Door Reed Switch - Sentrol Security & Access Control OCS Mark Cole Grandfather Rights Approved 26/02/2018 2707A N/A N/A
00510 1 Standard Door Reed Switch – Sentrol (Recessed) Security & Access Control OCS Mark Cole Grandfather Rights Approved 26/02/2018 1078 N/A N/A
00509 1 Electric Strike – Padde Security & Access Control OCS Mark Cole Grandfather Rights Approved 26/02/2018 ES2000 N/A N/A
00508 1 Electric Strike – Padde Security & Access Control OCS Mark Cole Grandfather Rights Approved 26/02/2018 ES9000 N/A N/A
00507 1 Lokitwell K series 2-pole Ezy2 Key Override Security & Access Control OCS Mark Cole Grandfather Rights Approved 26/02/2018 EZY2 N/A N/A
00506 1 Double Electric Lock - Padde Security & Access Control OCS Mark Cole Grandfather Rights Approved 26/02/2018 Z8 EML10 N/A N/A
00505 1 Power Transfer Lead 300mm Security & Access Control OCS Mark Cole Grandfather Rights Approved 26/02/2018 S4528 N/A N/A
00504 1 3570 Internal Plate with Lever Security & Access Control OCS Mark Cole Grandfather Rights Approved 26/02/2018 S1542A N/A N/A
00503 1 3570 External Plate with Lever Security & Access Control OCS Mark Cole Grandfather Rights Approved 26/02/2018 S1541A N/A N/A
00502 1 Electronic Mortice Lock Security & Access Control OCS Mark Cole Grandfather Rights Approved 26/02/2018 3570ELM0SC N/A N/A
00501 1 Universal Enclosure Security & Access Control OCS Mark Cole Grandfather Rights Approved 26/02/2018 TS0307 N/A N/A
00500 1 Fibre Interface Card Security & Access Control OCS Mark Cole Grandfather Rights Approved 26/02/2018 TS0896B N/A N/A
00499 1 LAN Distribution Board Security & Access Control OCS Mark Cole Grandfather Rights Approved 26/02/2018 TS0844 N/A N/A
00498 1 8 Input Expansion Module Security & Access Control OCS Mark Cole Grandfather Rights Approved 26/02/2018 TS1021 N/A N/A
00497 1 Data Gathering Panel Security & Access Control OCS Mark Cole Grandfather Rights Approved 26/02/2018 TS1020 N/A N/A
00496 1 Card Reader (Heavy duty) Security & Access Control OCS Mark Cole Grandfather Rights Approved 26/02/2018 TS0870H N/A N/A
00495 14DC + 2 x Card Readers (Heavy duty) V10 Compatible
FirmwareSecurity & Access Control OCS Mark Cole Grandfather Rights Approved 26/02/2018 TS0866KH N/A N/A
00494 14DC + 2 x Card Readers (Heavy duty) V7 Compatible
FirmwareSecurity & Access Control OCS Mark Cole Grandfather Rights Approved 26/02/2018 TS0866KH N/A N/A
00493 1 Remote Arming Station Security & Access Control OCS Mark Cole Grandfather Rights Approved 26/02/2018 CA1110 N/A N/A
00492 1 IP Ethernet Card Security & Access Control OCS Mark Cole Grandfather Rights Approved 26/02/2018 TS0099 N/A N/A
00491 1 16 Input Collector Card Security & Access Control OCS Mark Cole Grandfather Rights Approved 26/02/2018 TS0842 N/A N/A
00490 1 Memory Expansion Security & Access Control OCS Mark Cole Grandfather Rights Approved 26/02/2018 TS1082 N/A N/A
00489 1 Challenger Security Master Panel Security & Access Control OCS Mark Cole Grandfather Rights Approved 26/02/2018 TS1016 N/A N/A
00488 1 PC Workstations, Monitors, Servers and Storage equipment PC Workstations, Monitors, Servers and Storage equipment OCS Mark Cole Grandfather Rights Approved 26/02/2018 N/A N/A For current equipment standards refer to OCS Engineering Manager
00487 1 4 port High Speed Ethernet Extender over Coax IP Over Coax cable OCS Mark Cole Grandfather Rights Approved 26/02/2018 V2404A N/A N/AStandards Waiver Required For Use Of this Equipment
Approved for use in Analogue CCTV Renewals Project Only
00486 1 High Speed Ethernet Mini Extender Over Coax Cables IP Over Coax cable OCS Mark Cole Grandfather Rights Approved 26/02/2018 V12401A N/A N/AStandards Waiver Required For Use Of this Equipment
Approved for use in Analogue CCTV Renewals Project Only
00485 1 Mini High Speed Ethernet Mini Extender Over Coax Cables IP Over Coax cable OCS Mark Cole Grandfather Rights Approved 26/02/2018 Vi2400A N/A N/AStandards Waiver Required For Use Of this Equipment
Approved for use in Analogue CCTV Renewals Project Only
00484 1 8 & 16 port Coax Ethernet & POE Extender IP Over Coax cable OCS Mark Cole Grandfather Rights Approved 26/02/2018 Vi2608A/Vi2616A N/A N/AStandards Waiver Required For Use Of this Equipment
Approved for use in Analogue CCTV Renewals Project Only
00483 1KL1508MA-I Aten 19" rack mount 8 port KVM over IP Switch
with 17" screenAccessories OCS Mark Cole Grandfather Rights Approved 26/02/2018 S46283 N/A N/A
To be used for reactive/corrective maintnence only
Not be used in new installations or purchased.
00482 1 1RU KVM - 17" LCD monitor - Multiple input Accessories OCS Mark Cole Grandfather Rights Approved 26/02/2018 ATEN CL5708MA N/A N/ATo be used for reactive/corrective maintnence only
Not be used in new installations or purchased.
00481 1 Removed - requirement in Specification Racks OCS Mark Cole Grandfather Rights Approved 26/02/2018 As per CCTV Specification N/A N/A As per CCTV Specification
00480 1 24V ac Power supply for analogue cameras CCTV OCS Mark Cole Grandfather Rights Approved 26/02/2018Tactical Technologies RPS24-10-
D10-2RUN/A N/A
00479 1 12 V dc Power Supply for encoders CCTV OCS Mark Cole Grandfather Rights Approved 26/02/2018Tactical Technologies RPS12-
20DC-D20N/A N/A
00478 1 240V-12V ac-dc power supply general purpose CCTV OCS Mark Cole Grandfather Rights Approved 26/02/2018 Mean Well DR-120-12 N/A N/A
00477 1 48V - 12V dc-dc converter for 12V PTZ cameras CCTV OCS Mark Cole Grandfather Rights Approved 26/02/2018 Mean Well SD-100C-12 N/A N/A
00476 148 V dc power supply – Fitted with 20 x 6A load circuit
breakersCCTV OCS Mark Cole Grandfather Rights Approved 26/02/2018
Eaton Powerware APS6-320
rectifier system including APR48-
3G × 2 (1+1) 31A 48V, rectifiers,
integral 20-way load distribution,
N/A N/A
00475 148 V dc power supply – Fitted with 10 x 6A load circuit
breakersCCTV OCS Mark Cole Grandfather Rights Approved 26/02/2018
Eaton Powerware APS3-320
rectifier system including APR48-
3G × 2 (1+1) 31A 48V, rectifiers,
integral 10-way load distribution,
N/A N/A
00474 1 UPS Distribution Box Power OCS Mark Cole Grandfather Rights Approved 26/02/2018 WMDIN2 N/A N/A
00473 1 Automatic Transfer Switch Power OCS Mark Cole Grandfather Rights Approved 26/02/2018American Power Conversion
(APC) AP7723N/A N/A
To be used for reactive/corrective maintnence only
Not be used in new installations or purchased.
Please refer to L1-CHE-PRO-004 for T.A Procedure
Uncontrolled if printed. Controlled by MTM Eng. Systems (OCE)
Page 9 of 22 [email protected]
Metro Trains Melbourne Engineering Approved Product List As of 20/01/2020 (Updated monthly)
TA
NumberIssue Title/Product Function/Application(s)
Applicable
System(s)SME Approval Type Approval Status
Approval/Rejected
DateExpiry
Withdrawal/Suspension
DateType/Model Number
Hardware
Revision No.
Software Version
No.Manufacturer Place of Manufacture Condition and Service Restrictions
00472 1 UPS Extended Battery Module UPS OCS Mark Cole Grandfather Rights Approved 26/02/2018 9PXEBM72RT2U N/A N/ATo be used for reactive/corrective maintnence only
Not be used in new installations or purchased.
00471 1 3 kVA UPS UPS OCS Mark Cole Grandfather Rights Approved 26/02/2018 9PX3000IRTN N/A N/ATo be used for reactive/corrective maintnence only
Not be used in new installations or purchased.
00470 1 UPS Extended Battery Module UPS OCS Mark Cole Grandfather Rights Approved 26/02/2018 9SXEBM180RT N/A N/ATo be used for reactive/corrective maintnence only
Not be used in new installations or purchased.
00469 1 6 kVA UPS (Note: may need electrician to install) UPS OCS Mark Cole Grandfather Rights Approved 26/02/2018 9SX6KiRT N/A N/ATo be used for reactive/corrective maintnence only
Not be used in new installations or purchased.
00468 1 UPS SNMP Card - For all UPS types SNMP Alarm Interface / UPS OCS Mark Cole Grandfather Rights Approved 26/02/2018ConnectUPS-MS Network
Management CardN/A N/A
00467 1 UPS Environmental Monitoring probe - For all UPS types SNMP Alarm Interface / UPS OCS Mark Cole Grandfather Rights Approved 26/02/2018Powerware Environmental
Monitoring Probe (EMP)N/A N/A
00466 1 Single Channel Decoder 12V dc CCTV OCS Mark Cole Grandfather Rights Approved 26/02/2018 DVT-7401DA N/A N/A
00465 1Single Channel Encoder with audio POE, extended
temperature range (Inside Field LAN Switch assemblies)CCTV OCS Mark Cole Grandfather Rights Approved 26/02/2018 DVT-7401ETA N/A N/A
00464 1 Single Channel Encoder with audio 12VDC CCTV OCS Mark Cole Grandfather Rights Approved 26/02/2018 DVT-7801EA N/A N/A
00463 1 16 Channel Encoder with audio 12VDC CCTV OCS Mark Cole Grandfather Rights Approved 26/02/2018 DVT-EN216 N/A N/A
00462 1 8 Channel Encoder with audio 12VDCc CCTV OCS Mark Cole Grandfather Rights Approved 26/02/2018 DVT-EV208-A N/A N/A
00461 1 16 Channel Encoder 12VDC CCTV OCS Mark Cole Grandfather Rights Approved 26/02/2018 DVT-7608E N/A N/A
00460 1 6-12 port 12VDC Video Distribution Amplifier CCTV OCS Mark Cole Grandfather Rights Approved 26/02/2018 Pacom VDA816PR1 N/A N/A
00459 1225 serries padlock for camera housings (keyed CL001) -
API LocksmithsCCTV OCS Mark Cole Grandfather Rights Approved 26/02/2018 225/40/119/LF N/A N/A
00458 1Security screws for camera mounting brackets and housings
(Keys available from MTM only) - Austra GoldCCTV OCS Mark Cole Grandfather Rights Approved 26/02/2018
F7 Barrinuts from Austra Gold
(small & large formfactor
available)
N/A N/A
00457 1 Mounting bracket for IWM24-GY on corner CCTV OCS Mark Cole Grandfather Rights Approved 26/02/2018 CM400 N/A N/A
00456 1 Mounting bracket for IWM24-GY on pole CCTV OCS Mark Cole Grandfather Rights Approved 26/02/2018 PA402 N/A N/A
00455 1 Adaptor plate for PTZ CCTV OCS Mark Cole Grandfather Rights Approved 26/02/2018 FX-150 N/A N/A
00454 1Mounting bracket for PTZ dome camera – suitable for
mounting to wall type surfaceCCTV OCS Mark Cole Grandfather Rights Approved 26/02/2018 IWM24-GY N/A N/A
00453 1Mounting bracket – For mounting EH3512 to top of pole (if
pole does not come with mounting bracket) or under roofCCTV OCS Mark Cole Grandfather Rights Approved 26/02/2018 MM22 N/A N/A
00452 1Mounting bracket – For mounting EH3512 to top of pole (if
pole does not come with mounting bracket) or under roofCCTV OCS Mark Cole Grandfather Rights Approved 26/02/2018 EM1009U & EM1015U N/A N/A
00451 1 Mounting bracket – For mounting EH3512 to pole CCTV OCS Mark Cole Grandfather Rights Approved 26/02/2018 EM2000 N/A N/A
00450 1 Mounting bracket – For mounting EH3512 to building CCTV OCS Mark Cole Grandfather Rights Approved 26/02/2018 EM1450 N/A N/A
00449 1Recessed Wedge Camera Housing with 12mm glass and
security screws - SEE SecurityCCTV OCS Mark Cole Grandfather Rights Approved 26/02/2018 RMW5 with adaptor kit N/A N/A
00448 1Wedge Camera Housing with 12mm glass and security
screws - SEE SecurityCCTV OCS Mark Cole Grandfather Rights Approved 26/02/2018 SMW5 with adaptor kit N/A N/A
00447 1Corner-mount Camera Housing with 12mm glass and
security screws - SEE SecurityCCTV OCS Mark Cole Grandfather Rights Approved 26/02/2018 CHM02 with adaptor kit N/A N/A
00446 1 Fixed Camera Housing, in line - Pelco CCTV OCS Mark Cole Grandfather Rights Approved 26/02/2018 EH4712DB N/A N/A Special order fitted with 268 lock barrel
00445 1 Fixed Camera Housing Wall Mount High Security CCTV OCS Mark Cole Grandfather Rights Approved 26/02/2018 CMH02WM N/A N/A
00444 1 Fixed Camera Housing, in line - Pelco CCTV OCS Mark Cole Grandfather Rights Approved 26/02/2018 EH3512 N/A N/A
00443 1 Analogue Camera (24V AC or 12V DC), normal duty. CCTV OCS Mark Cole Grandfather Rights Approved 26/02/2018Panasonic SD634 Model No:
WVC-P634N/A N/A WV-CP634
00442 1 POE+ Injector for use with CP-4221-201 PTZ CCTV OCS Mark Cole Grandfather Rights Approved 26/02/2018 Moxa INJ-24A-T N/A N/A
00441 1 IP PTZ Dome Camera, POE+ CCTV OCS Mark Cole Grandfather Rights Approved 26/02/2018 DVTel Quasar CP-4221-301 N/A N/A Heater/demister function inoperative on POE+
00440 1 8.0 – 50.0 mm f1.6 varifocal HD IR lens CCTV OCS Mark Cole Grandfather Rights Approved 26/02/2018 Tamron M13VG850IR (s45379) N/A N/A
00439 1 2.8-10.0 mm f1.2 varifocal Megapixel lens CCTV OCS Mark Cole Grandfather Rights Approved 26/02/2018 Computar AG4Z2812FCS-MPIR N/A N/A
00438 1 IP Fixed Camera with integral analitics CCTV OCS Mark Cole Grandfather Rights Approved 26/02/2018 DVTEL Quasar CF-5222-00 N/A N/A
To be used for reactive/corrective maintnence only
Not be used in new installations or purchased.
Requires Latitude 6.3 Camera Pack 1
00437 1 IP Fixed Camera for CHP's and choke points CCTV OCS Mark Cole Grandfather Rights Approved 26/02/2018 DVTel Quasar CF-4221-00 N/A N/A
00436 1 Ethernet Remote Terminal Unit Controller Remote Terminal Unit Controllers OCS Mark Cole Grandfather Rights Approved 26/02/2018 Moxa ioLogik E2210-T N/A N/A
00435 1 Ethernet Extender Ethernet Extenders OCS Mark Cole Grandfather Rights Approved 26/02/2018 EtherWan ED3146-22B N/A N/ATo be used for reactive/corrective maintnence only
Not be used in new installations or purchased.
00434 1 Summit layer 2 switch Field LAN Switch OCS Mark Cole Grandfather Rights Approved 26/02/2018Summit-X430-24P(Part No
16517)N/A N/A
00433 1 Expansion module - 2 port Field LAN Switch Options OCS Mark Cole Grandfather Rights Approved 26/02/2018 MB-2T N/A N/A
00432 1 PoE 100baseT interface × 4 module Field LAN Switch Options OCS Mark Cole Grandfather Rights Approved 26/02/2018 MM22-4T1 N/A N/A
00431 1 100baseFx interface module (for fibre connected cameras) Field LAN Switch Options OCS Mark Cole Grandfather Rights Approved 26/02/2018 MM3-4FXM2 N/A N/A
Please refer to L1-CHE-PRO-004 for T.A Procedure
Uncontrolled if printed. Controlled by MTM Eng. Systems (OCE)
Page 10 of 22 [email protected]
Metro Trains Melbourne Engineering Approved Product List As of 20/01/2020 (Updated monthly)
TA
NumberIssue Title/Product Function/Application(s)
Applicable
System(s)SME Approval Type Approval Status
Approval/Rejected
DateExpiry
Withdrawal/Suspension
DateType/Model Number
Hardware
Revision No.
Software Version
No.Manufacturer Place of Manufacture Condition and Service Restrictions
00430 1 dual 1000baseSX interface Field LAN Switch Options OCS Mark Cole Grandfather Rights Approved 26/02/2018 MM4-2TX/SFP N/A N/A
00429 1 Basic switch + backplane unit (24 port) Field LAN Switch Options OCS Mark Cole Grandfather Rights Approved 26/02/2018 MS30-2402TCAPHH06.0 N/A N/A
00428 1 Basic switch + backplane unit (16 port) Field LAN Switch Options OCS Mark Cole Grandfather Rights Approved 26/02/2018 MS30-1602TCAPHHXX.X N/A N/A
00427 1 48 VDC Hirschmann Switch Field LAN Switch Options OCS Mark Cole Grandfather Rights Approved 26/02/2018 Hirschmann MS30 Series N/A N/A
00426 1 8ch Single Core Mux Side 'B' CWDM Mux/DeMux OCS Mark Cole Grandfather Rights Approved 26/02/2018MD-8CH-1RU-CWDM-1310-
LCSX-BN/A N/A
00425 1 8ch Single Core Mux Side 'A' CWDM Mux/DeMux OCS Mark Cole Grandfather Rights Approved 26/02/2018MD-8CH-1RU-CWDM-1310-
LCSX-AN/A N/A
00424 1 10/100/1000TX SFP (Copper) Copper SFPs OCS Mark Cole Grandfather Rights Approved 26/02/2018 AT-SPTX N/A N/ATo be used for reactive/corrective maintnence only
Not be used in new installations or purchased.
00423 1 Hirschmann 1Gb 850nm SFP - 550m Multimode SFPs OCS Mark Cole Grandfather Rights Approved 26/02/2018 M-SFP-SX/LC N/A N/ATo be used for reactive/corrective maintnence only
Not be used in new installations or purchased.
00422 1 Allied Telesis 100Mb 1310nm SFP - 2km Multimode SFPs OCS Mark Cole Grandfather Rights Approved 26/02/2018 AT-SPFX-2 N/A N/ATo be used for reactive/corrective maintnence only
Not be used in new installations or purchased.
00421 1 Allied Telesis 1Gb 850nm SFP - 550m Multimode SFPs OCS Mark Cole Grandfather Rights Approved 26/02/2018 AT-SPSX N/A N/ATo be used for reactive/corrective maintnence only
Not be used in new installations or purchased.
00420 1 Allied Telesis 10GBE 1550nm XFP - 40km Single Mode 10GBE XFP / XENPACK OCS Mark Cole Grandfather Rights Approved 26/02/2018 AT-XPER40 N/A N/ATo be used for reactive/corrective maintnence only
Not be used in new installations or purchased.
00419 1 Allied Telesis 10GBE 1310nm XFP - 10km Single Mode 10GBE XFP / XENPACK OCS Mark Cole Grandfather Rights Approved 26/02/2018 AT-XPLR N/A N/ATo be used for reactive/corrective maintnence only
Not be used in new installations or purchased.
00418 1 PlusOptics SFPs Optics OCS Mark Cole Grandfather Rights Approved 26/02/2018
SFPs are ordered from
PlusOptics to suit the intended
application i.e. switch vendor, OF
type, wavelength, distance etc.
N/A N/A Refer OCS Engineering for assistance if required
00417 1 Full Layer 3 license upgrade, Extreme Networks Site Master Switch OCS Mark Cole Grandfather Rights Approved 26/02/2018
ExtremeXOS Advanced Core
License Upgrade from Edge
License (Part No. 16422)
N/A N/A
00416 1 Redundant, Hot pluggable 240V PSU, Extreme Networks Site Master Switch OCS Mark Cole Grandfather Rights Approved 26/02/2018
Summit x460 AC PSU (Part No.
10930 Standard Temperature
Range)
Summit x460 AC PSU (Part No.
N/A N/A
00415 1 Layer 3 Switch & Modules Site Master Switch OCS Mark Cole Grandfather Rights Approved 26/02/2018
Summit x460-G2 24T (Part No
16701)
Summit x460-G2 24X (Part No
16705)
N/A N/A Refer to e-mail from Mark cole - 'OCS approved products.msg'
00414 1 Pelco Camera Enclosure A rugged camera enclosure compatible with existing cameras. OCS Damien Watson Engineering Product Approval Approved 17/04/2018 EH20 N/A N/A Pelco USA Nil
00413 1 Quasar 1080p IR PTZ Camera A PTZ, IP Camera with FHD 1080p, PoE++, IR-illumination and Gyro-based image stabilization. OCS Damien Watson Engineering Product Approval Approved 17/04/2018 CP-6302-31-I N/A N/A FLIR TaiwanFollow maintenance/cleaning instructions detailed in FLIR PTZ Camera Cleaning
Instructions.pdf
00412 1 PTZ Network CameraA PTZ, IP Camera with H.264+, 1080P and PoE.
Intelligent Video Surveillance features: Tripwire, Intrusion, Abandoned/Missing, Face Detection.OCS Damien Watson Engineering Product Approval Approved 25/05/2018 DH-SD22204T-GN N/A N/A Dahua China
For use in internal spaces such corridors, booking offices and lifts, where aesthetics and size
restrictions apply.
00411 1
FLIR Quasar 4K Camera Model CF-6308-00-0 with lens
Wide: Computar EG3Z3915FCS-MPWIR (3.9-10mm) or
Tele: Tamron M118VG1250IR (12-50mm)
An IP Camera with H.264, H.265 4K + 1080p, PoE, and Enhanced Low Light Performance mode
ONVIF compliant, and compatible with our existing DVTel NVMSOCS Damien Watson Engineering Product Approval Approved 17/04/2018 CF-6308-00-0 N/A N/A FLIR Taiwan
The camera will be installed in an approved camera housing in order to provide adequate weather
protection and vandal resistance.
Both Computar EG3Z3915FCS-MPWIR and the Tamron M118VG1250IR are the only approved
00410 1 FLIR Ariel 3MP Corner Camera
An IP corner-shape form factor camera with H.264, PoE and IR illumination.
The extended field of view lens provides ceiling-to-floor and wall-to-wall coverage ideal for elevators.
ONVIF compliant, and compatible with our existing DVTel NVMS.
OCS Damien Watson Engineering Product Approval Approved 17/04/2018 CC-3103-01-I N/A N/A FLIR Taiwan Nil
00409 1 Siemens ET200SP PLC Providing remote indication and/or control of plant equipment such as pumps,HVAC units, lifts, escalators, etc...). OCS Niels Endres Engineering Product Approval Approved 16/02/2018 ET200SP N/A N/A Siemens Australia Germany
CP1543SP-1 shall be used for any upstream (non-local) network connections.
Not to be used for vital signalling
00408 1 10kVA 1ph 3.3kV/2.2kV-110V IP23 TransformerSupply of 110V signalling loads from the 3.3kV/2.2kV Essential Services Distribution System when connected to Essential Services Trackside
Switchgear conforming to MESP 041000-01 and mounted within a suitable secured and weatherproof enclosure or building.Substations Craig Tooke Full Type Approval In Progress 41.10.xxxxx N/A N/A Circle- C Transformers
Minto Factory, Sydney,
AustraliaPart number 41.10.xxxxx, “xxxxx” shall be allocate after receipt of the order.
00407 1 NanoBeam wireless network bridgeThe Ubiquiti NanoBeam is a point-to-point wireless network bridge, allowing for the network connection of two buildings when it is impractical to
run network cabling.OCS Niels Endres Engineering Product Approval Approved 16/02/2018 NBE-5AC-Gen2 N/A N/A Ubiquiti China
Radio antenna shall be installed inside a sealed plastic junction box to provide additional weather
and vandal protection.
Redundant power supply options (e.g. UPS) shall be considered as part of a risk assessment.
Device shall be configured to only use the following outdoor channels:
00406 1 APC Transfer SwitchesThe AP44xx range of Transfer Switches provides the capability of automatically switching to secondary power source should the primary source
fails.OCS Niels Endres Engineering Product Approval Approved 16/02/2018
10A Model – AP4421
16A Model – AP4423 N/A N/A APC China N/A
00405 1 Eaton 9PX UPS Eaton 9PX UPS OCS Niels Endres Engineering Product Approval Approved 16/02/2018
3kVA Unit - 9PX3000IRT2U (with
optional 9PXEBM72RT EBM)
6kVA Unit - 9PX6Ki (with optional
9PX EBM 180V EBM)
N/A N/A Eaton China and Philippines
Network-MS module shall be installed and connected to a central monitoring system.
In locations that do not have temperature monitoring, the Environmental Monitoring Probe shall be
installed.
00404 1 3 & 4 Feeder Assembly
The proposed feeder clamp is to be used where multiple auxiliary feeder conductors are run in close proximity to provide mid-span mechanical
support (prevent adjacent conductors from clashing or rubbings due to excitation from wind) and provide an additional electrical path for current
sharing between adjacent conductors.
Overhead Craig/Izy Full Type Approval Withdrawn 27/06/2018 STD_E2018/’N’ N/A N/A Australia
00403 1 Enatel RW624U-21, -10, -11, -20 Power supply and battery charger combined Signals Glenn Miller Full Type Approval Approved 12/02/2018 N/A Enatel RW624U-21, -10, -11, -20 N/A N/A Enatel Limited New Zealand New Zealand
00402 1MTM 1.5KV DC UNSC TERM 1C XLPE 500MM2 W.
ALUMINIUM LUG I/OThe termination kit will be used to terminate at the rectifier end aluminium BUS. Substations Craig Tooke Under Development Registered
PTC-TK500-US-AL
N/A N/ARaychem & Utilux (TE
CONNECTIVITY)Germany
00401 1MTM 1.5KV DC UNSC TERM 1C XLPE 500MM2 W. BI-
METAL LUG I/OThe termination kit will be used to terminate the at the negative pillar and the negative BUSBAR. Substations Craig Tooke Under Development Registered
PTC-TK500-US-BG
N/A N/ARaychem & Utilux (TE
CONNECTIVITY)Germany
00400 1MTM 1.5KV DC SCR TERM 1C XLPE 500MM2 W. BI-
METAL LUG O/DOORThe termination kit will be used to terminate the cable outside on the Overhead switchmasts. Substations Craig Tooke Under Development Registered PTC-TK500-SCOBG N/A N/A
Raychem & Utilux (TE
CONNECTIVITY)Germany
00399 1MTM 1.5KV DC SCR TERM 1C XLPE 500MM2 W. BI-
METAL LUG I/DOORThe termination kit will be used on the positive end of DCCB copper BUS. Substations Craig Tooke Under Development Registered PTC-TK500-SCIBG N/A N/A
Raychem & Utilux (TE
CONNECTIVITY)Germany
00398 1MTM 1.5KV DC SCR TERM 1C XLPE 500MM2 W.
ALUMINUM LUG I/DOORThe termination kit will be used on the positive end of the rectifier aluminium bus. Substations Craig Tooke Under Development Registered PTC-TK500-SCIAL - N/A N/A
Raychem & Utilux (TE
CONNECTIVITY)Germany
00397 1 1.9kV AC transformer secondary to rectifier termination kitProduct will be used to terminate single core the 500mm
2 Copper XLPE insulated cable without metallic screen (Metro Trains
specification L1-CHE-SPE-147). Substations Craig Tooke Under Development Registered PTC-TK500-ACI-BG N/A N/A
Raychem & Utilux (TE
CONNECTIVITY)Germany
00396 1 1.9kV AC transformer secondary to rectifier termination kitProduct will be used to terminate single core the 500mm
2 Aluminium XLPE insulated cable without metallic screen (Metro Trains
specification L1-CHE-SPE-147). Substations Craig Tooke Full Type Approval Registered PTC-TK500-ACI-AL N/A N/A
Raychem & Utilux (TE
CONNECTIVITY)Germany
00395 1 Solar Pathway Light Marker Used for the viaduct walkways Structures Joe Cavric Engineering Product Approval Approved 9/03/2018 M2 N/A N/A SolarPath Sun Solutions South Korea 4/1/18: Sent for SME Review
00394 1 Recordable Voice Module Tram approaching and arrival voice alarm playback. Signals Glenn Miller Under Development In Progress ELK-124 v.3 ELK Products USA 4/1/18: Sent for SME Review
00393 1 MRD earth sense insulation monitor Earth leakage detection monitor for signalling and other systems Signals Glenn Miller Full Type Approval Approved 5/04/2018 N/AMRD earth sense insulation
monitor ESM1-Ana na MRD Australia
00392 1 Fibreglass Storage Tanks Underground storage of storm water and sewer Structures NA Under Development Withdrawn 16/09/2019 AQES/9885/2020 N/A N/A Aquatec Australia
00391 1SIEMENS type Aluminium fibreglass composite level crossing
boom armAlternative boom arm for level crossing boom for use both under the overhead witing and in non electrified areas Signals
Lee Charnock/Colin
WatersProvisional Type Approval Approved 12/02/2019 30/10/2019 Refer to certificate N/A N/A siemens australia
15/6/18 and waiting on MoC process, and risk assessment, and also Siemens to supply a product
for approval
Email and response 22/10 stated equipment will be ready by end of next week.
17/07/2019 - Siemens finalising Boom extension to meet requirement's of LED Light spacing on
00390 1TAKEX PHOTOELECTRIC BEAM SENSOR ANTI-CRAWL
HIGH SECURITY PHOTOBEAMTunnel Intruder Detection Systems OCS Robert Raic Grandfather Rights Approved 18/12/2017 PB-IN-100AT N/A N/A Takex Japan Nil
Please refer to L1-CHE-PRO-004 for T.A Procedure
Uncontrolled if printed. Controlled by MTM Eng. Systems (OCE)
Page 11 of 22 [email protected]
Metro Trains Melbourne Engineering Approved Product List As of 20/01/2020 (Updated monthly)
TA
NumberIssue Title/Product Function/Application(s)
Applicable
System(s)SME Approval Type Approval Status
Approval/Rejected
DateExpiry
Withdrawal/Suspension
DateType/Model Number
Hardware
Revision No.
Software Version
No.Manufacturer Place of Manufacture Condition and Service Restrictions
00389 1TAKEX PHOTOELECTRIC BEAM SENSOR (INTELLIGENT
QUAD SERIES)Tunnel Intruder Detection Systems OCS Robert Raic Grandfather Rights Approved 18/12/2017 PB-IN-50HF N/A N/A Takex Japan Nil
00388 1 Siemens HC200 flashing light housing Housing for level crossing flashing light Signals Lee Charnock Full Type Approval Approved 21/12/2017HC200 and in acordance to
drawing 2501-14 rev 2NA NA Siemens Australia
00387 1 Alstom Smartlock GP Computer Based Interlocking system. Signals Lee Charnock Under Development Withdrawn NA
00386 1 Router Cable Minilogger system used for remote condition monitoring of fixed assets Signals Lee Charnock Grandfather Rights Approved 11/12/2017 EVNSL27E-0001-90DU N/A N/A Voestalpine Germany
00385 1 PCM CT Cable 12m Minilogger system used for remote condition monitoring of fixed assets Signals Lee Charnock Grandfather Rights Approved 11/12/2017 CTPLAT-112-BM-001 N/A N/A Voestalpine Germany
00384 1 PCM CT Cable 5m Minilogger system used for remote condition monitoring of fixed assets Signals Lee Charnock Grandfather Rights Approved 11/12/2017 CTPLAT-105-BM-001 N/A N/A Voestalpine Germany
00383 1 PCM CT Cable 4m Minilogger system used for remote condition monitoring of fixed assets Signals Lee Charnock Grandfather Rights Approved 11/12/2017 CTPLAT-104-BM-001 N/A N/A Voestalpine Germany
00382 1 PCM CT Cable 2m Minilogger system used for remote condition monitoring of fixed assets Signals Lee Charnock Grandfather Rights Approved 11/12/2017 CTPLAT-102-BM-001 N/A N/A Voestalpine Germany
00381 1 PCM CT (Unistar) Minilogger system used for remote condition monitoring of fixed assets Signals Lee Charnock Grandfather Rights Approved 11/12/2017 CTPLAT-100-BM-012 N/A N/A Voestalpine Germany
00380 1 Switch Minilogger system used for remote condition monitoring of fixed assets Signals Lee Charnock Grandfather Rights Approved 11/12/2017 NETKIT-000-BM-001 N/A N/A Voestalpine Germany
00379 1 CRmagnetics CR4620-150 - AC Transducer Minilogger system used for remote condition monitoring of fixed assets Signals Lee Charnock Grandfather Rights Approved 11/12/2017 CTGKIT-000-BM-001 N/A N/A Voestalpine Germany
00378 1 Ambient Temp Sensor Minilogger system used for remote condition monitoring of fixed assets Signals Lee Charnock Grandfather Rights Approved 11/12/2017 Ocean Controls KTD-267 N/A N/A Voestalpine Germany
00377 1 Temp Thermistor Minilogger system used for remote condition monitoring of fixed assets Signals Lee Charnock Grandfather Rights Approved 11/12/2017 ETP-CS N/A N/A Voestalpine Germany
00376 1 Rail Temp Sensor Minilogger system used for remote condition monitoring of fixed assets Signals Lee Charnock Grandfather Rights Approved 11/12/2017 RTSCAB-0000-BM-005 N/A N/A Voestalpine Germany
00375 1 Rail Temp Sensor 20m Minilogger system used for remote condition monitoring of fixed assets Signals Lee Charnock Grandfather Rights Approved 11/12/2017 RTSCAB-000-BM-004 N/A N/A Voestalpine Germany
00374 1 Rail Temp Sensor 10m Minilogger system used for remote condition monitoring of fixed assets Signals Lee Charnock Grandfather Rights Approved 11/12/2017 RTSCAB-000-BM-002 N/A N/A Voestalpine Germany
00373 1 Router w/Dome Minilogger system used for remote condition monitoring of fixed assets Signals Lee Charnock Grandfather Rights Approved 11/12/2017 ROUKIT-001-BM-006 N/A N/A Voestalpine Germany
00372 1 Router w/Magnetic Whip Minilogger system used for remote condition monitoring of fixed assets Signals Lee Charnock Grandfather Rights Approved 11/12/2017 ROUKIT-000-BM-006 N/A N/A Voestalpine Germany
00371 1 VT1 Minilogger Minilogger system used for remote condition monitoring of fixed assets Signals Lee Charnock Grandfather Rights Approved 11/12/2017 VT1HCL-003-BM-103 N/A N/A Voestalpine Germany
00370 1 Minilogger 2 Minilogger system used for remote condition monitoring of fixed assets Signals Lee Charnock Grandfather Rights Approved 11/12/2017
MINTWO-621-BM-103
MINTWO-641-BM-102
MINTWO-691-BM-103
MINTWO-681-BM-103
N/A N/A Voestalpine Germany
00369 1 Minilogger HD Minilogger system used for remote condition monitoring of fixed assets Signals Lee Charnock Grandfather Rights Approved 11/12/2017MINANG-531-BM-103
MINANG-631-BM-103N/A N/A Voestalpine Germany
00368 1 Minilogger Minilogger system used for remote condition monitoring of fixed assets Signals Lee Charnock Grandfather Rights Approved 11/12/2017MINHCL-068-BM-103
MINHCL-084-BM-103N/A N/A Voestalpine Germany
00367 1 Unistar HR EM electro-mechanic point machine. Electro-mechanic point machine. SignalsLee Charnock/Colin
WatersGrandfather Rights
Suspended (Until Further
Notice)UNISTAR HR EM N/A N/A Voestalpine Germany
00366 1 SEL Protective 751A Relay Digital AC Protection Relay Substations Tim Leech Full Type Approval Approved 16/02/2018SEL-751A -
751A52C0X0X0X841320 N/A N/A
Schweitzer Engineering
LaboratoriesWashington State, USA
The relay shall be installed and used in accordance with manufacturer recommendations.
Test links shall be installed on all connections of the relay to facilitate testing.
Protection study and report shall be developed for the scheme to ensure the relay is suitable and
required.
00365 1 NEXCOM NISE 3600E Industrial PCThe NISE 3600E Industrial PC is proposed for Technician Workstation, Control System Gateway and Site PC applications of WESTLOCK
installations in CPLSU and PEDS projectsSignals
Lee Charnock/Gail
SmithFull Type Approval Approved 16/12/2019 NISE 3600E N/A N/A APC Technology Australia
00364 1 WestCAD for Windows 7WestCAD utilised across MTM network running on Windows XP to be used as Signaller Control Panel (SCP) & Control System Protocol
Converter (CSPC) Signals Wayne Purton Full Type Approval Approved 21/02/2018 Siemens UK & australia
00363 1 Cooper Earthing Crimp Connection on bare aerial copper conductors Overhead Craig Tooke Full Type Approval Approved 23/01/2018 GCE250-259 N/A N/A Panduit Mexico
The crimp can only be used to crimp the following conductors:
181mm² catenary wire to 181mm² feeder wire
181mm² catenary wire to 100mm² jumper wire
161mm² catenary wire to 100mm² jumper wire
00362 1 Essential services cable termination kit (XIRIA) Used to terminate 3 core, 3.8/6.6kV, and 35mm2 copper conductor, XLPE insulated with metallic screen (L1-CHE–SPE-148). Substations Craig Tooke Full Type Approval In Progress PTC-TK-350-IEX N/A N/ARaychem (TE
CONNECTIVITY)Germany
00361 1 Essential services cable termination kit (PREMSET) Used to terminate 3 core, 3.8/6.6kV, and 35mm2 copper conductor, XLPE insulated with metallic screen (L1-CHE–SPE-148). Substations Craig Tooke Full Type Approval In Progress PTC-TK-350-IEP N/A N/A
Raychem (TE
CONNECTIVITY):
heatshrink and cable
breakout.
Germany/Belgium
00360 1 3.8/6.6kv Single Core (Prysmian)For use with an Essential Services Distribution System (3.3kv) where the Combined Services Route does not allow the specified 3 core cable to
be installed and/or joined due to pit sizesSubstations Craig Tooke Provisional Type Approval Approved 7/03/2018 7/09/2018 1CCUX6HD N/A N/A Prysmian China
Power Quality analysis of the existing 2.2kV system shall be performed prior to installation to
ascertain the baseline power quality. This shall be performed under both the normal feeding
arrangement (feeding down) and n-1 condition (feeding up). Measurements shall be taken at the
feeding end, final location and a location in between. An Inspection Test Procedure shall be
00359 1 3.8/6.6kv Single Core (Olex)For use with an Essential Services Distribution System (3.3kv) where the Combined Services Route does not allow the specified 3 core cable to
be installed and/or joined due to pit sizesSubstations Craig Tooke Provisional Type Approval Withdrawn 7/03/2018 7/09/2018 NA XHHP18AA001 N/A N/A Nexans Olex China
Power Quality analysis of the existing 2.2kV system shall be performed prior to installation to
ascertain the baseline power quality. This shall be performed under both the normal feeding
arrangement (feeding down) and n-1 condition (feeding up). Measurements shall be taken at the
feeding end, final location and a location in between. An Inspection Test Procedure shall be
00358 1 Transformer (TMC) The Essential Services Supply Distribution System requires step down transformers to supply the nominated Low Voltage loads. Substations Wesley Allen Full Type Approval Withdrawn 13/11/2018
TMT130303300-DD-IP22
TMT130353300-DD-IP22
TMT130303300-DD-IP43
TMT130603300-DD-IP22
N/A N/A TMC Australia
00357 1 Transformer (TMC)To allow supply 110V signal single phase loads from 3 phase 400V ESDS distribution.
Substations Wesley Allen Full Type Approval Withdrawn 13/11/2018 TMT150030400A N/A N/A TMC Australia
00356 1Roxtec Multi Cable Transits and Seals – Multilayer
Technology
The system provides a complete solution for cable sealing from 3mm till 99mm in the standard range utilising multi diameter technology, along
with this there is a complete customised solution offering as well for specialised applications. Substations David Hutchison Engineering Product Approval In Progress
S1010379B,
S1010383A,S1025599C
S1025599C,S1025601C,S10057
17,
N/A N/A Roxtec Sweden
00355 1 UGL 1500V 4MW Rectifier
For use in supplying overhead 1500V DC power for rail traction system.
Stand alone
Substations
David
Hutchison/Craig
Tooke
Full Type Approval Approved 3/10/2019 5000-0382 & 5000-0421 N/A N/A UGL Australia
00354 1 Lock Nut (M27) Fastening heel bolts in Points and Crossings. Track Timothy Powell Grandfather Rights Approved 17/11/2017 1603-0027-300-G-P N/A N/A Security Locknut USA Refer to e-mail from T&S -HoE
00353 1 Lock Nut (M24) Fastening Fish bolts in mechanical joints and mechanical insulated rail joints. Track Timothy Powell Grandfather Rights Approved 17/11/2017 1651-0024-300-G-P N/A N/A Security Locknut USARefer to e-mail from T&S -HoE
Trialed under EC:IF-14-067-PC
00352 1 Nord-Lock Washer (M24) Fastening Fish bolts in mechanical joints and mechanical insulated rail joints. Track Timothy Powell Grandfather Rights Approved 17/11/2017 NL24 N/A N/A Nord-Lock SwedenRefer to e-mail from T&S -HoE,
Trialed under EC:IF-14-089-PC
00351 1 MCE Lightweight Marker Board Possession limit board Track Salar Tavakoli Full Type Approval Approved 14/11/2017MCE 1402
Pads No: 0020/039499N/A N/A MC Electronics United Kingdom
00350 1 MCE lightweight Portable Possession Limit Board Possession limit board Track Salar Tavakoli Full Type Approval Approved 14/11/2017MCE 205STK
Pads No 057/072981N/A N/A MC Electronics United Kingdom
00349 1 Wavetrain Level Crossing Warning System (LCWS)
The application of this equipment is currently limited to the scope of the Wavetrain Wheel Flat Detection trial, which aims to determine the
viability for additional use of the wavetrain sensors around the network. The trial will involve attaching the sensors at a specific location on the
network for a set period of time.
The wheel flat detection trial will take place on running line where there is a section of track clear of points and IRJs to reduce noise. This will
Track Glenn Miller Full Type Approval Withdrawn N/A N/A 7/02/2018 1310-21741 1.3 1.3 WaveTrain Systems AS Norway Refer to e-mail from Jennifer Nguyen, WaveTrain EC .msg, TA not required anymore.
Please refer to L1-CHE-PRO-004 for T.A Procedure
Uncontrolled if printed. Controlled by MTM Eng. Systems (OCE)
Page 12 of 22 [email protected]
Metro Trains Melbourne Engineering Approved Product List As of 20/01/2020 (Updated monthly)
TA
NumberIssue Title/Product Function/Application(s)
Applicable
System(s)SME Approval Type Approval Status
Approval/Rejected
DateExpiry
Withdrawal/Suspension
DateType/Model Number
Hardware
Revision No.
Software Version
No.Manufacturer Place of Manufacture Condition and Service Restrictions
00348 1 Easy Access Signal MastTo provide greater clearance to ensure drivers can observe the signals within signal sighting distance under certain circumstances. To
accommodate HCMT, all signal masts must be 5.5 metres tall on elevated sections of track. Signals Glenn Miller Full Type Approval Registered 5.5 metre mast, fold down type N/A N/A Siemens Australia
00347 1 Relocatable Equipment BuildingTo maintain the required signalling equipment environment when subject to all of the climatic conditions in Victoria. This includes allowance for a
shade air temperature of –10 degrees Celsius to +45 degrees Celsius with a relative humidity of 95%Signals Glenn Miller Full Type Approval Withdrawn N/A N/A NA Structure N/A N/A Siemens Australia/New Zealand
00346 1 Siemens SFP TransceiversFast Ethernet small form-factor pluggable (SFP) transceivers provide an interface between compatible network routers and switches and a
single, single mode optical fibre for point to point fast Ethernet data transmission.OCS Niels Endres Full Type Approval Approved 8/12/2017 N/A
SFP1132-1BX40T
6GK60008FB540AA0
SFP1132-1BX40R
6GK60008FB530AA0
Siemens Canada
In deployments where 40km SFPs are used (SFP1132-1BX40T and SFP1132-1BX40R) with fibre
runs of less than 12km, passive optical attenuator(s) shall be fitted to achieve a minimum
attenuation of 6dB in the fibre link.
00345 1 Essential services cable joint kit Used to join two 3 core, 3.8/6.6kV, and 35mm2 copper conductor, XLPE insulated with metallic screen (L1-CHE–SPE-148) cable ends together. Overhead Craig Tooke Full Type Approval Registered PTC–JK-350 N/A N/A Raychem Germany / Australia
00344 1 Concrete Canvas 5mm
Concrete canvas is a Flexible mat containing a dry concrete mix trapped within a 3 dimensional Fibre matrix with a fibrous surface on one side
and a PVC Membrane on the other.
When water is added, the material remains workable for 2 Hours and then hardens to form a concrete sheet.
The Material is supplied on a roll and comes in a range of thicknesses up to 20mm.
Structures Gordon Djurdjevic Engineering Product Approval Registered CC5 N/A N/A Concrete Canvas UK
00343 1 Single Phase 400V/110V -3kVA Step-down TransformerSignalling loads require a single phase 110V supply. The most efficient way to provide this is via a 400V/110V single phase transformer. The
use of 400V helps isolate the supply from potential local earthing disturbances that could impact a 240V/110V transformer.
Electrical
Networks
Alan Keating, Lee
CharnockFull Type Approval Approved 4/07/2018
TMT150030400A
TMT150100400A
TMT150150400A
N/A N/A TMC Australia Nil
00342 1 Innostrail
• Innostrail is a similar product to pedestrail used on the network, however it is designed for light to medium road traffic loads
• InnoStrail is a high-strength and durable covering for level crossings, which can be manufactured very economically due to the larger panel
measurements
• The panels are removable to allow for maintenance to be preformed
Track Gordon Djurdjevic Provisional Type Approval Approved 17/11/2017 17/05/2018 Innostrail N/A N/AGummiwerk KRAIBURG
Elastik GmbHGermany
00342 3 Innostrail
• Innostrail is a similar product to pedestrail used on the network, however it is designed for light to medium road traffic loads
• InnoStrail is a high-strength and durable covering for level crossings, which can be manufactured very economically due to the larger panel
measurements
• The panels are removable to allow for maintenance to be preformed
Track Gordon Djurdjevic Full Type Approval Approved 16/12/2019 Innostrail N/A N/AGummiwerk KRAIBURG
Elastik GmbHGermany
00341 1 Protection IV Track Lubrication SystemLB Foster lubricators can be used on plain line track, as well as sidings and crossovers. The units can be used for rail/wheel flange lubrication,
application of top of rail friction modifier, and application of traction gels.Track Liam PC Provisional Type Approval Approved 17/11/2017 17/03/2018 Protector IV N/A N/A
LB Foster Rail Technologies
Ltd.United States
1. The performance, monitoring and inspections of the trial lubricator after installation shall be
assessed in accordance with the technical note detailed in Attachment 1. The technical note defines
the inspection process and details the criteria to be applied to check and monitor the effectiveness
and performance of the Protector IV Trackside Friction Management System.
00341 2 Protection IV Track Lubrication SystemLB Foster lubricators can be used on plain line track, as well as sidings and crossovers. The units can be used for rail/wheel flange lubrication,
application of top of rail friction modifier, and application of traction gels.Track Nathan Baker Provisional Type Approval Approved 24/05/2019 24/11/2019 Protector IV N/A N/A
LB Foster Rail Technologies
Ltd.United States
1. The performance, monitoring and inspections of the trial lubricator after installation shall be
assessed in accordance with the technical note detailed in Attachment 1. The technical note defines
the inspection process and details the criteria to be applied to check and monitor the effectiveness
and performance of the Protector IV Trackside Friction Management System.
00340 1 Relocatable Equipment Building (REB)
Structure to house signalling equipment. Two types:
Small – 4955mm x 3305mmSignals Glenn Miller Full Type Approval approved 24/11/2017 N/A
SRS Power Pty Ltd
Large Size Fire rated Equipment
BuildingN/A N/A Siemens Australia
1. A detailed design process shall be undertaken to identify any application and site specific
requirements to determine the appropriate REB size and type.
00339 1 Junction Rail AS60kg – AS47kgFor use in the transition from different rail profiles, an example being new 60kg rail interfacing with existing 47kg rail. These will predominately
be located in interfaces from new track and old. Track Hassan Elaina Full Type Approval Approved 20/10/2017 440.081431.W01 N/A N/A Vossloh Australia
1. Welded junction rails shall be installed in accordance with the requirements of the Welded Track
Management Manual with specific reference to closure rails and Section 4 of MTPR 033000-11 -
Chapter 11, Rail Welding Process
2. Welded junction rails shall be a minimum of 13.7m in length.
00338 1 DC-DC Converter To provide 48V DC supply from an existing 125V DC power supply.Electrical
NetworksGeorge Marulli Full Type Approval Rejected 13/11/2017 SD-500H-48 N/A N/A Mean Well Taiwan
00337 1 Single Phase Dry Transformer - 3.3kV/1kV (50kVA) To allow supply of the existing 1000V signalling system from a new 3.3kV ESDS supply.Electrical
NetworksAlan Keating Full Type Approval Approved 26/07/2018 TBC N/A N/A TMC Australia Nil
00336 1 Exduro - FRP Cable Trough
The Treadwell FRP Cable Trough is a light weight , non-corrosive, non-conductive, competitively priced alternative to the current metal cable
trough used.
This product has a high strength to weight ratio and provides a design life of 55 years. The material is UV stable and fire tested to meet the
relevant ASTM standards.
Signals Glenn Miller Full Type Approval Registered FRP Cable Trough N/A N/A Treadwell India
00335 1 Powerjoint - termination kit 3 core 185 sq.mm screened aluminium cable outdoor terminationsElectrical
NetworksCraig Tooke Engineering Product Approval Approved 30/08/2017 H22o1X3T3 (outdoor) N/A N/A Legend Power China For use on outdoor 22 kV cable terminations only
00334 1 Powerjoint - termination kit 3 core 185 sq.mm screened aluminium cable indoor terminationsElectrical
NetworksCraig Tooke Engineering Product Approval Approved 30/08/2017 H22iX3T2 (indoor) N/A N/A Legend Power China For use on indoor 22 kV cable terminations only
00333 1 Powerjoint - termination kit 3 core 35 sq. mm screened Cu cableElectrical
NetworksCraig Tooke Engineering Product Approval Approved 30/08/2017 H6i1X2MT012 (outdoor) N/A N/A Legend Power China
• Approved 35 sq. mm cable as per L1-CHE-SPE-148
• For use in cable terminations inside Eaton Xiria switchgear
• Type approved high voltage cable boots to be fitted over the termination
00332 1 Powerjoint - termination kit 1 core 500 sq.mm screened positive Aluminium cable outdoor terminationsElectrical
NetworksCraig Tooke Engineering Product Approval Approved 30/08/2017 H60500BLMT02 Bimetal Lug N/A N/A Legend Power China For use on outdoor 1500 volt equipment only
00331 1 Powerjoint - termination kit 1 core 500 sq.mm screened positive Aluminium cable indoor terminationsElectrical
NetworksCraig Tooke Engineering Product Approval Approved 30/08/2017
H61500MT01 Aluminium Lug &
H6i500BLMMT03 Bimetal LugN/A N/A Legend Power China For use on indoor 1500 volt equipment only
00330 1 StormPRO-Polypropylene Storm water pipe
StormPRO-Polypropylene Storm water pipe.
• 6m Lengths approximately
• Lightweight-Safer as no heavy machinery is required for pipe 150mm-450mm
• Range 150mm-900mm
Structures Graeme Miles Engineering Product Approval Withdrawn N/A N/A 15/12/2017
p/n:29479 -150mm diameter -
150 StormPRO2 SN8 PP
6.020m length
p/n:29456 -225mm diameter -
N/A N/A Vinidex Australia
00329 1 AUSGROUP Grade AcrylicAcrylic panels that offers light transmission matching that of glass, typically has higher strength and half the weight, and is commonly used for
high traffic acoustic barriers.Structures Anant Gupta Engineering Product Approval Approved 8/02/2018 Noisewall Grade Acrylic N/A N/A PALRAM Israel
00328 1 SEL Protective RelayUse in providing protection in MTM’s internal HV network. These will be located in substations within the LV compartment of the HV switchgear
as an upgrade to the MiCOM P127 to accommodate additional protection functionality for the UPS installations.
Electrical
NetworksAlan Keating Full Type Approval Approved 20/09/2017
SEL-751 /
751401DCD3D70830320 (for
110V or 125V DC Supplies) or
751402CCC3C70830320 (for
Firmware:R200-
V2N/A
Schweitzer Engineering
LaboratoriesWashington State, USA
The relay shall be installed and used in accordance with manufacturer recommendations.
Test links shall be installed on all connections to the relay to facilitate testing.
Protection study and report shall be developed for the scheme to ensure the relay is suitable and
required.
00327 1 3-Phase 60-30kVA Step-up TransformerThis 60-30kVA transformer is intended to be used in a substation on the output of the UPS to step the voltage up from 400V to 3300-2200V.
Single-phase versions of this transformer have previously been type approved; this type approval is simply for the 3-phase version.
Electrical
NetworksAlan Keating Full Type Approval Registered TMT110603322-IP22-dYN11 N/A N/A TMC Australia
00326 1 VLD-H The Secheron TVP-H is specifically used for DC traction system. Electrical
Networks
Jansen
MekkaringattuFull Type Approval Withdrawn NA SG891020Rxxxxx. N/A N/A Secheron Czech Republic
00325 15395kVA 11000/581-581V Dd0y11 AN IP43 CAST RESIN
TRANSFORMERRectifier Transformer
Electrical
NetworksAlan Keating Provisional Type Approval Withdrawn N/A NA TMT034MW11-B N/A N/A TMC Australia
00324 1 Weathering Steel - CladdingUsed for cladding purposes
(Engineering Product Approval covers cladding only)Structures John Dauth Engineering Product Approval Superseded 25/08/2017
Bluescope XLERPLATE® to
AS/NZS 3678 – WR350 and
WR350L0
Bluescope TRU-SPEC® and Hot
N/A N/A Bluescope Australia
00324 2 Weathering Steel - CladdingUsed for cladding purposes
(Engineering Product Approval covers cladding only)Structures John Dauth Engineering Product Approval Approved 28/08/2017
Bluescope XLERPLATE® to
AS/NZS 3678 – WR350 and
WR350L0
Bluescope TRU-SPEC® and Hot
N/A N/A Bluescope Australia
00323 1100-50kVA 400/3300-2200V dYN11 Cast Resin Step-up
TransformerEssential Services / Auxiliary Transformer
Electrical
NetworksAlan Keating Full Type Approval Approved 17/11/2017 TMT111003322-IP22-dYN11 N/A N/A TMC Australia
The transformer shall be installed indoors.
Requirement for the primary side circuit breaker shall be determined by the designer of the intended
installation and an appropriate unit selected based on the protection discrimination requirements if
00322 1 Cubis STAKKABox
Features the same twinwall, sectional design as the standard system but sections are built from combining multiple parts (all parts are
manufactured in GRP). The system comprises of corner pieces and sidewall length. There are left and right handed corner pieces, which offers
the ability to offset joints between sections in order to provide a brickwork effect.
Electrical
NetworksGeorge Marulli Full Type Approval Registered
00321 1 Microelettrica Relay
This product is a DC Substation Protective Relay which will be installed in the KDA DC Switchgear to provide protection on MTM’s DC feeders.
This product will replace the existing Balfour Beatty DCP106 Relay which will be phased out over time. This product offers DC feeder protection
relay with setting parameters programmable locally or via serial communication. Suitable for protection of D.C. feeders with High-Speed DC
Breakers, for railway application.
Electrical
NetworksGeorge Marulli Provisional Type Approval Approved 5/12/2017 4/06/2018
UMLESPLVTS12
2S12
Firmware version:
Mcore: 0832.35.02.A
Dsp: 024.01.D Refer
to attached test
Microelettrica Scientifica Italy
00320 1ART 3000VDC / 4000A Single Throw Wall and Mast
Mounted Switches
Product overview (include description, benefits, limitations). The above mentioned switches are direct replacements for existing ART switches
with an increased continuous current rating of 4000 Amps. The PTV have instructed the CTD project to install 1500V switches rated at 4000
Amps to allow the running of the new HMCT trains in 2019.The existing ART switches are only rated at 1500 Amps. The new switches perform
the same functions as the existing switches. The proposed switches have the same mounting arrangement as the existing switches and will be
Overhead Izy Perona Full Type Approval Approved 13/09/2017 N/A
XP669.2D00-2000 Mast mount
Retro fit
XP669.2D00-2001 Mast mount
Short
N/A N/A Australian Rail Technology Australia
00319 1 Tapered rail joint shims
Rail joint shims fit inside and along the upper fishing surface of mechanical joints to return them to their design longitudinal plan thereby
eliminating dipped fish plated joints, voiding and mud holes in the area of joints.
Unquantified savings will be made due to reduced maintenance, reactive works and reductions to PWM’s.
Track Hassan Elaina Provisional Type Approval Withdrawn 16/08/2017 15/11/2017 6/06/2019 AS47kg Joint Shim set - - Bance England
1. A 3 month trial shall be conducted at Lilydale siding, using shims for 47kg rail. A report shall be
provided after the trial to validate and confirm successful performance in the field. Where a trial is
found to be unsuccessful, the shims shall be removed from track.
2. Bance Joint Shims shall not be used:
00318 1 Phoenix Contact “Plug in Block” and also Connectors” For use in Westrace MK2 Computer Based Interlocking and similar type applications within the MTM Melbourne Rail Network Signals Jim Warwick Engineering Product Approval Approved 26/07/2017Due to multiple part numbers
refer to submission form- - Pheonix connectors Germany Nil Conditions
00317 1 Bluey GRP Soil NailsBluGeo GRP60 is a Glass-Fibre Reinforced Plastic continuously threaded solid bar which forms a high load carrying capacity ground anchor and
soil nail.Structures John Dauth Full Type Approval Approved 25/07/2017 BluGeo GRP60 - - Bluey Technologies China
• Bluey GRP Soil Nails shall be designed, installed and tested insitu in accordance with VicRoads
Section 683 Soil Nail Walls.
• Documentation shall be supplied for each batch of Bluey GRP Soil Nails delivered to site to
evidence that the approved Quality Control procedures have been followed.
00316 1 SPX In Bearer AssemblyThe SPX In Bearer Assembly is an in-bearer assembly for the MKIII modular clamp lock point machine available with a hydraulic or electro-
mechanical drive.Signals Glenn Miller Provisional Type Approval Approved 17/08/2017 15/11/2017 AP106230 - - SPX United Kingdom
1. The Provisional Type Approval is valid for the trial period which shall be concluded after three (3)
months service from the date of installation. If the trial is unsuccessful, the point machine shall be
removed.
2. The user shall ensure that he/she is fully aware of and complies with the information given in
00316 2 SPX In Bearer AssemblyThe SPX In Bearer Assembly is an in-bearer assembly for the MKIII modular clamp lock point machine available with a hydraulic or electro-
mechanical drive.Signals Glenn Miller Full Type Approval Approved 4/02/2019 Refer to certificate - - SPX United Kingdom
1. The Provisional Type Approval is valid for the trial period which shall be concluded after three (3)
months service from the date of installation. If the trial is unsuccessful, the point machine shall be
removed.
2. The user shall ensure that he/she is fully aware of and complies with the information given in
00315 1 TMC 160kVA 22000/400V ES&A Transformer Essential Services / Auxiliary Transformer SubstationsJames Webb/Craig
TookeProvisional Type Approval In Progress 1/09/2017 TMT0516022-BD-IP43-Dyn1 N/A N/A TMC Australia
00314 1 Lynx Series Industrial Ethernet Routing SwitchesFull Layer 2 and Layer 3 capabilities including VPN, static and dynamic routing, firewall, cyber security features, network configuration
management tools are supported.OCS Damien Watson Engineering Product Approval Approved 17/08/2017 L210-F2G ; L208-F2G-S2 v10 4.21 Westermo Sweden
1. Purchasing:
When deployed in a new geographic location for the first time, shall be purchased / supplied with
the Westermo specific console cable (Part Number 1211-2027).
2. Deployment:
00313 1 Rebosio Strut and Post InsulatorsThe Earthing, Bonding and Electrolysis Mitigation Strategy, it was recommended that the 1500V DC traction system be electrically separated
from the OHW mast using a single insulator with a basic insulator level (BiL) greater than 250kV and a flashover distance greater than 500mm. Overhead Izy Perona Full Type Approval Approved 24/01/2018
I02080 (Strut Insulator), I02079
(Post InsulatorNA NA Bonomi Italy
For use on the CTD project Elevated Viaduct only. May be used in other areas of the network
providing an insulation co-ordination report is conducted to the satisfaction of the Chief Engineer or
Delegate.
00312 1 SEL Protective RelayFor use in providing protection in MTM’s internal 22kV network. These will be located in substations within a dedicated protection cabinet. These
relays require an interconnected fibre for communication purposes. Substations Alan Keating Full Type Approval Approved 1/08/2017 SEL-411L / SEL-311L NA NA SEL USA
Where provided for Line Differential Protection (ANSI 87L), shall be used in conjunction with a type
approved GPS clock, network switch and either dedicated fibres or other approved secure network.
The relay shall be installed and used in accordance with manufacturer recommendations.
Test links shall be installed on all connections to the relay to facilitate testing.
Please refer to L1-CHE-PRO-004 for T.A Procedure
Uncontrolled if printed. Controlled by MTM Eng. Systems (OCE)
Page 13 of 22 [email protected]
Metro Trains Melbourne Engineering Approved Product List As of 20/01/2020 (Updated monthly)
TA
NumberIssue Title/Product Function/Application(s)
Applicable
System(s)SME Approval Type Approval Status
Approval/Rejected
DateExpiry
Withdrawal/Suspension
DateType/Model Number
Hardware
Revision No.
Software Version
No.Manufacturer Place of Manufacture Condition and Service Restrictions
00311 1 SENTRON PAC3200The SENTRON PAC3200 is a Power Monitoring Device for displaying all the relevant system parameters in low-voltage power distribution. It is
capable of single-phase, two-phase or three-phase measurement and can be used in two-wire, three-wire, four-wire, TN, TT and IT systems.OCS Leigh Davies Engineering Product Approval Approved 17/07/2017 SENTRON PAC3200 V2.4.3 or newer Siemens Hungary
00310 1 Modular clamp lock point machine
The SPX Clamplock is a modular clamp lock point machine available with a hydraulic or electro-mechanical drive.
The MK3 presents an improvement in Mean Time Between Service Affecting Failure from 3.5 years from the MK2 to 7 years.
The MK2 has been trialled beyond its trial period and has not failed. Signals Jim Warwick Full Type Approval Approved 7/06/2018 N/A Clamplock - MK3 na na SPX United Kingdom
As of the 7/6/2018 the SPX unit MK3 is fully type approved, and refer to certificates and
recommendation for use.
00309 1 Miniature relays TYPE BRB930 Series
These miniature relays are used in signalling and rail systems areas of MTM, for both vital and non-vital applications. Typical applications such
as, signal circuits, train stop controls, track circuits, point circuits, level and pedestrian crossing circuits, signalling interlocking functionality over
the entire MTM Network.
Signals Glenn Miller Full Type Approval Approved 14/09/2017Miniature relays TYPE BRB930
SeriesN/A N/A Mors Smitt.UK Ltd UK Refer to certificate
00309 2Miniature relays TYPE BRB930 Series (QECX/QUCX Lamp
Proving Realy Included)
These miniature relays are used in signalling and rail systems areas of MTM, for both vital and non-vital applications. Typical applications such
as, signal circuits, train stop controls, track circuits, point circuits, level and pedestrian crossing circuits, signalling interlocking functionality over
the entire MTM Network.
SignalsLee Charnock/Colin
WatersFull Type Approval Approved 12/07/2017
Miniature relays TYPE BRB930
Series (QECX/QUCX Lamp
Proving included)
N/A N/A Mors Smitt.UK Ltd UK
00308 1 160kVA 11000/400V Transformer Essential Services / Auxiliary TransformerElectrical
NetworksAlan Keating Provisional Type Approval Approved 21/06/2017 20/06/2018 TMT0516011-BD-IP43-Dzn0 N/A N/A TMC Australia
Standard drawings for product shall be produced in PTV compliant format and booked into DMS.
Prior to commissioning, Type Testing and Routine Testing on a unit to AS 60076.11 including
sound level and temperature rise testing shall be undertaken to the satisfaction of MTM
00307 1 TPWS PVC 2 core electrical cableIt is a 2 core 2.5 mm
2, 50/0.25 mm
2 Stranding, 0.6/1kV, XLPE X-90 insulated, 5V-90 PVC sheathed, with drain wire 2.5mm², and
metallic tape screen. Signals Lee Charnock Full Type Approval Approved 7/08/2017
2 core 2.5 mm2, 50/0.25 mm
2
Stranding, 0.6/1kV, XLPE X-90
insulated, 5V-90 PVC
sheathed, with drain wire
N/A N/A Prysmian Group Australia The cable shall not be used in the MURL or similar type tunnel applications
00306 1TMC 200kVA 11000/400V Dzn0 AN IP21 CAST RESIN
TRANSFORMEREssential Services / Auxiliary Transformer Substations
James Webb/Craig
TookeFull Type Approval In Progress TMT0520011-BD-IP21-Dzn0 N/A N/A TMC Australia
00305 1 ShapeShell Architectural Cladding Architectural Cladding Structures Louis Knap Engineering Product Approval Approved 23/06/2017 Free Form ‘Monocoque’ N/A N/A Vector Foiltec Indonesia
Shapeshell is accepted for use as an architectural cladding material at Carnegie, Murrumbeena,
Hughesdale, Clayton and Noble Park Stations only. Installation at other locations shall be subject to
approval, which will take into consideration access provisions for maintenance and repairs including
ability to paint over in the event of scratching using a paint roller and a standard Dulux paint colour
00304 1 Series 3593E Boom Mechanism Boom Mechanism used for operating boom arms at level crossings. Signals Jim Warwick Provisional Type Approval Superseded 8/06/2017 9/09/2017 3593E N/A N/A Western-Cullen-Hayes USA
References contained within these conditions are made to “Provisional Type Approval Report WCH
3593E Boom Mechanism” version 1 dated 08/06/2017.
1) The Provisional Type Approval is valid for three (3) months from the date of approval.
2) The user shall ensure that he/she is fully aware of and complies with the information given in
00304 1 Series 3590 Boom Mechanism
The WCH Series 3590 Boom Mechanism operates level crossing boom arms and is used extensively in the United States, with Sydney Trains,
in the ARTC Network, TasRail and with CRN.
The mechanism was first installed in NSW in 1975 and there have been no changes to the design or with manufacturing since then. The
mechanism has a proven record of reliability and ease of maintenance in the ARTC Network.
Signals Jim Warwick Full Type Approval Approved 20/07/2018 3593E N/A N/A Western-Cullen-Hayes USA
1) The user shall ensure that they are fully aware of and comply with the information provided in
“WCH Model 10 Signals with 3590 Series Gate Mechanism – Service and installation manual”
revision 11/95.
2) Western-Cullen-Hayes and its supplier shall retain ISO 9001 accreditation and inform MTM of
00303 1 Powerjoint - termination kitRectifier and rectifier transformer indoor and outdoor 581 V termination kits aluminium and bimetal lugs, Negative pillar outdoor aluminium
termination lugs
Electrical
NetworksCraig Tooke Engineering Product Approval Approved 30/08/2017
H6N500BLMT04
H6N500BLMT05
H1R500ALMT06
H1R500BLMT07
N/A N/A Legend Power China For use on rectifier transformer, negative busbar and rectifier low voltage terminations only
00302 1 OneSteel 47kg RailTo be used for rail closures for RFD repair in accordance with MTPR 033000-10 – Welded Track Management Manual Chapter 10 – Closure
RailsTrack Timothy Powell Grandfather Rights Approved 30/05/2018 47kg Rail N/A N/A
OneSteel Whyalla
SteelworksAustralia
1. The first batch of 47kg rail produced is to undergo testing and OneSteel to validate compliance in
accordance with AS1085.1-2002 - Railway track materials Part 1: Steel rails
2. To be used for rail closures for RFD repair in accordance with MTPR 033000-10 – Welded Track
Management Manual Chapter 10 – Closure Rails
00301 1 Lai Negative Pillar outdoor Trackside negative pillarElectrical
NetworksCraig Tooke Full Type Approval Approved 1/11/2017 N/A N/A N/A LAI Switchboards Australia
00300 1 GageLok Rail Screws GageLok screws can be used in timber and composite sleepers. Track Hassan Elaina Provisional Type Approval Approved 7/07/2017 6/01/2018 N/A N/AHaiyan Guangda Hardware
Co. LtdChina
• A 6 month trial shall be conducted at selected sites, for each screw type, and a report provided to
validate performance in the field, prior to the commencement of trial, the MoC and EC process shall
be followed including the development of trials success criteria.
• All dog and lock screws shall be inserted in accordance with the manufacturer’s procedures
00300 2 GageLok Rail Screws GageLok screws can be used in timber and composite sleepers. Track Hassan Elaina Full Type Approval Approved 19/10/2018 GageLok-7 (SP295-7) N/A N/AHaiyan Guangda Hardware
Co. LtdChina
Rail screws shall be inserted in accordance with the
manufacturer’s procedures. Refer to Attachment 1 for details.
• Haiyan Guangda Hardware Co. Ltd shall have ISO9001
accreditation and ensure GageLok Rail screws sourced from
00299 1 Mors Smitt Miniature Relays BRB930 Series
These miniature relays are used in signalling and rail systems areas of MTM, for both vital and non-vital applications. Typical applications such
as, signal circuits, train stop controls, track circuits, point circuits, level and pedestrian crossing circuits, signalling interlocking functionality over
the entire MTM Network.
Signals Glenn Miller Full Type Approval In ProgressMiniature relays TYPE
BRB930 SeriesN/A N/A Mors Smitt.UK Ltd UK
00298 1 Variable speed driveThe main function of the Altivar Process / Machines products ranges is the speed control and variation of a synchronous, asynchronous or
reluctance electric motor for fluid management and industrial applications.Structures Joe Cavric Full Type Approval Superseded 20/07/2017 ATV650D45N4 - V1.3 IE15 Schneider Electric France / China
1. Shall comply with AS 61800.3 and IEC 61000
2. Technical Backup support shall be available 24 hours 7 days a week.
3. Potential for voltage spikes and electro –magnetic interference from VSD to Vic track equipment
shall have incorporated AC line reactors, Sinus filters and cables shielding.
00298 2 Variable speed driveThe main function of the Altivar Process / Machines products ranges is the speed control and variation of a synchronous, asynchronous or
reluctance electric motor for fluid management and industrial applications.Structures Joe Cavric Full Type Approval Approved 23/08/2017 ATV650D45N4 - V1.3 IE15 Schneider Electric France / China
1. Shall comply with AS 61800.3 and IEC 61000
2. Technical Backup support shall be available 24 hours 7 days a week.
3. Potential for voltage spikes and electro –magnetic interference from VSD to Vic track equipment
shall have incorporated AC line reactors, Sinus filters and cables shielding.
00297 1 Variable speed driveThe main function of the Altivar Process / Machines products ranges is the speed control and variation of a synchronous, asynchronous or
reluctance electric motor for fluid management and industrial applications.Structures Joe Cavric Full Type Approval Superseded 20/07/2017 ATV630D45N4 - V1.3 IE15 Schneider Electric France / China
1. Shall comply with AS 61800.3 and IEC 61000
2. Technical Backup support shall be available 24 hours 7 days a week.
3. Potential for voltage spikes and electro –magnetic interference from VSD to Vic track equipment
shall have incorporated AC line reactors, Sinus filters and cables shielding.
00297 2 Variable speed driveThe main function of the Altivar Process / Machines products ranges is the speed control and variation of a synchronous, asynchronous or
reluctance electric motor for fluid management and industrial applications.Structures Joe Cavric Full Type Approval Approved 23/08/2017 ATV630D45N4 - V1.3 IE15 Schneider Electric France / China
1. Shall comply with AS 61800.3 and IEC 61000
2. Technical Backup support shall be available 24 hours 7 days a week.
3. Potential for voltage spikes and electro –magnetic interference from VSD to Vic track equipment
shall have incorporated AC line reactors, Sinus filters and cables shielding.
00296 1 Witt & Sohn Reversible Axials (NR Series)
Reversible axial fan complete with special corrosion resistant cast aluminium with inner steel skeleton impeller blade design suited for high
temperature and heavy industrial applications.
Independently laboratory certified for temperature rating upto 400degC/2 hours.
Structures Lachlan Henderson Full Type Approval Withdrawn N/A N/A 20/07/2017Witt & Sohn Reversible Axials
(NR Series)N/A N/A Witt & Sohn Germany
00295 1 Syfonic Drainage SystemSyfonic Roof Drainage is an efficient alternative to draining storm water from roof areas compared with conventional systems which have been
used traditionally.Structures Anil Kumar Engineering Product Approval Superseded 30/05/2017 SS01 G NA Syfon Systems Australia
•The Syfonic Roof Drainage System is accepted for use at Carnegie, Murrumbeena, Hughesdale,
Clayton and Noble Park Stations only. Installation at other locations shall be subject to approval,
which will take into consideration maintainability (e.g. service life,
non-proprietary components, removal of blockages), specific design (e.g. pipe run lengths, number
00295 2 Syfonic Drainage SystemSyfonic Roof Drainage is an efficient alternative to draining storm water from roof areas compared with conventional systems which have been
used traditionally.Structures Anil Kumar Engineering Product Approval Approved 16/10/2017 SS01 G Syfon Systems Australia
The Syfonic Roof Drainage System was initially accepted for use at Carnegie, Murrumbeena,
Hughesdale, Clayton and Noble Park Stations only. This revised approval aims to extend the
approval to other sites. The design and installation of the system will take into consideration
maintainability (e.g. service life, non-proprietary components, removal of blockages), specific design
00294 1 Siemens Derail and Crowder MK11The derail is used for the protection against run away vehicles, with the crowder component being used to prevent the derailed vehicle from then
becoming “re-railed”Signals Jim Warwick Full Type Approval Approved 24/08/2017
Siemens Derail and Crowder
MK11
Switchguard
D150 derail
MK11,and
crowder MK11
NA Siemens Australia
That the following Conditions shall be met;
1. Only the following listed part numbers shall to be purchased and used within MTM Network
areas,
a. Left Hand Installation Requirement-Derail D150 and Crowder C150, 1600mm gauge,
00293 1 Thermal OverloadFor use in the Siemens JAH and JAE trainstops as a thermal overload, for the protection of the trainstop motor in the advent of a failure/other
that allows the motor to drive for longer than necessary within normal operations.Signals Jim Warwick Full Type Approval In Progress Thermal Overload
Hybrid thermal
overload for
JAH.JAE
NA Siemens Australia
00292 13 pairs 1.5 mm2 (7/0.5 mm) Plain Annealed Copper, 0.6/1 kV
XLPE InsulatedLocal cable connection between the Signal Mast Junction box and signal head. Signals Glenn Miller Full Type Approval Approved 22/08/2017
CU/X90/HFS110/OSCR/HFS110
3X2X1.5NA NA Prysmian China This cable shall not be used in the MURL or similar type tunnel applications
00291 13 pairs 1.5 mm2 (7/0.5 mm) Plain Annealed Copper, 0.6/1 kV
XLPE Insulated
Three pairs 1.5 mm2 (7/0.5 mm) Plain Annealed Copper, 0.6/1 kV XLPE Insulated (0.7 mm min av wall), Laid up, HFS-90-TP Bedded (2.0 mm
nom wall), Copper taped, HFS-110-TP Sheathed (3.0 mm min av wall), Fire Safe Cable generally to AS/NZS 5000.1 and generally to VRIOGS
Standard 012.6.37Signals Glenn Miller Full Type Approval Approved 22/08/2017 IHO184RD003BZVY NA NA Nexans Olex Australia/New Zealand This cable shall not be used in the MURL or similar type tunnel applications
00290 14 pair 1.5 mm2 (7/0.5 mm) Plain Annealed Copper, 0.6/1 kV
XLPE InsulatedLocal cable connection between the Signal Mast Junction box and signal head. Signals Glenn Miller Full Type Approval Approved 22/08/2017
CU/X90/HFS110/OSCR/HFS110
4X2X1.5NA NA Prysmian China This cable shall not be used in the MURL or similar type tunnel applications
00289 14 pairs 1.5 mm2 (7/0.5 mm) Plain Annealed Copper, 0.6/1 kV
XLPE Insulated
4 pairs 1.5 mm2 (7/0.5 mm) Plain Annealed Copper, 0.6/1 kV XLPE Insulated (0.7 mm min av wall), Laid up, HFS-90-TP Bedded (2.0 mm nom
wall), Copper taped, HFS-110-TP Sheathed (3.0 mm min av wall), Fire Safe cable generally to AS/NZS 5000.1 and generally to VRIOGS
Standard 012.6.37.Signals Glenn Miller Full Type Approval Approved 22/08/2017 IHO184RD004BZVY NA NA Nexans Olex Australia/New Zealand This cable shall not be used in the MURL or similar type tunnel applications
00288 1 Acrylic Screen Use for the viaduct screens on the south side in all areas on LXRP -CTD. Structures Alan Keating Full Type Approval Withdrawn N/A N/A 25/01/2018 IHO184RD004BZVY NA NA PALRAM Israel
00287 1 Station Post Insulator 22kV Buswork Insulation for outdoor use within substationsElectrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017 SPI340-12-12-RB NA NA EMC Pacific
00286 1 PSG/LAI VD4 Indoor AC Switchgear Assembly Indoor 22kV Switchgear, Indoor 11kV SwitchgearElectrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017 NA NA PSG or LAI Shop drawing approval by MTM Engineering required prior to manufacture
00285 1 Micom P127 Protection Relay AC Protection Relay for use on 11kV/22kV systemsElectrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017 NA NA Areva, Alstom or Schneider
00284 1 Micom P123 Protection Relay AC Protection Relay for use on 1kV/6.6kV/11kV/22kV systemsElectrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017 NA NA Areva, Alstom or Schneider
00283 1 Micom P122 Protection Relay AC Protection Relay for use on 1kV/6.6kV/11kV/22kV systemsElectrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017 NA NA Areva, Alstom or Schneider
00282 1 Micom P120 Protection Relay Single Phase AC protection relay for use on earth fault protection and 650V/2.2kV systemsElectrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017 NA NA Areva, Alstom or Schneider
00281 1 KDA - Whipp & Bourne Transition Cubicle Bus connections between KDA and Whipp & Bourne DC BusesElectrical
NetworksAlan Keating Grandfather Rights Withdrawn 15/04/2017 9/01/2019 NA NA UGL Sydney Shop drawing approval by MTM Engineering required prior to manufacture
00280 1 KDA Rectifier DCCB Enclosed 4000A 48V Control Rectifier DCCBElectrical
NetworksAlan Keating Grandfather Rights Withdrawn 15/04/2017 9/01/2019 NA NA UGL France/Sydney Shop drawing approval by MTM Engineering required prior to manufacture
00279 1 KDA Rectifier DCCB Enclosed 4000A 125V Control Rectifier DCCBElectrical
NetworksAlan Keating Grandfather Rights Withdrawn 15/04/2017 9/01/2019 NA NA UGL France/Sydney Shop drawing approval by MTM Engineering required prior to manufacture
00278 1 KDA Master Feeder DCCB Enclosed 2000A 48V Control Feeder DCCBElectrical
NetworksAlan Keating Grandfather Rights Withdrawn 15/04/2017 9/01/2019 NA NA UGL France/Sydney Shop drawing approval by MTM Engineering required prior to manufacture
00277 1 KDA Master Feeder DCCB Enclosed 2000A 125V Control Feeder DCCBElectrical
NetworksAlan Keating Grandfather Rights Withdrawn 15/04/2017 9/01/2019 NA NA UGL France/Sydney Shop drawing approval by MTM Engineering required prior to manufacture
Please refer to L1-CHE-PRO-004 for T.A Procedure
Uncontrolled if printed. Controlled by MTM Eng. Systems (OCE)
Page 14 of 22 [email protected]
Metro Trains Melbourne Engineering Approved Product List As of 20/01/2020 (Updated monthly)
TA
NumberIssue Title/Product Function/Application(s)
Applicable
System(s)SME Approval Type Approval Status
Approval/Rejected
DateExpiry
Withdrawal/Suspension
DateType/Model Number
Hardware
Revision No.
Software Version
No.Manufacturer Place of Manufacture Condition and Service Restrictions
00276 1 KDA Feeder DCCB Enclosed 2000A 48V Control Feeder DCCBElectrical
NetworksAlan Keating Grandfather Rights Withdrawn 15/04/2017 9/01/2019 NA NA UGL France/Sydney Shop drawing approval by MTM Engineering required prior to manufacture
00275 1 KDA Feeder DCCB Enclosed 2000A 125V Control Feeder DCCBElectrical
NetworksAlan Keating Grandfather Rights Withdrawn 15/04/2017 9/01/2019 NA NA UGL France/Sydney Shop drawing approval by MTM Engineering required prior to manufacture
00274 1KDA Bus-Tie Isolator Enclosed 4000A 48V Control (Cable or
Busbar type)Bus-Tie DC Isolator
Electrical
NetworksAlan Keating Grandfather Rights Withdrawn 15/04/2017 9/01/2019 NA NA UGL France/Sydney Shop drawing approval by MTM Engineering required prior to manufacture
00273 1KDA Bus-Tie Isolator Enclosed 4000A 125V Control (Cable
or Busbar type)Bus Tie DC Isolator
Electrical
NetworksAlan Keating Grandfather Rights Withdrawn 15/04/2017 9/01/2019 NA NA UGL France/Sydney Shop drawing approval by MTM Engineering required prior to manufacture
00272 1KDA Bus-Tie DCCB Enclosed 4000A 48V Control (Cable or
Busbar type)Bus-Tie DCCB
Electrical
NetworksAlan Keating Grandfather Rights Withdrawn 15/04/2017 9/01/2019 NA NA UGL France/Sydney Shop drawing approval by MTM Engineering required prior to manufacture
00271 1KDA Bus-Tie DCCB Enclosed 4000A 125V Control (Cable or
Busbar type)Bus-Tie DCCB
Electrical
NetworksAlan Keating Grandfather Rights Withdrawn 15/04/2017 9/01/2019 NA NA UGL France/Sydney Shop drawing approval by MTM Engineering required prior to manufacture
00270 1 DCCB Rectifier W&B Enclosed Rectifier DCCBElectrical
NetworksAlan Keating Grandfather Rights Withdrawn 15/04/2017 9/01/2019 NA NA Whipp & Bourne Great Britain Suitable for use in existing Whipp & Bourne installations only
00269 1 DCCB Rectifier JR12 Exposed Rectifier DCCBElectrical
NetworksAlan Keating Grandfather Rights Withdrawn 15/04/2017 9/01/2019 NA NA Various Suitable for renewals only
00268 1 DCCB Feeder W&B Enclosed Feeder DCCBElectrical
NetworksAlan Keating Grandfather Rights Withdrawn 15/04/2017 9/01/2019 NA NA Whipp & Bourne Great Britain Suitable for use in existing Whipp & Bourne installations only
00267 1 DCCB Feeder JR12 Exposed Feeder DCCBElectrical
NetworksAlan Keating Grandfather Rights Withdrawn 15/04/2017 9/01/2019 NA NA Various Suitable for renewals only
00266 1 DCCB Bus-Tie W&B Enclosed Bus-Tie DCCBElectrical
NetworksAlan Keating Grandfather Rights Withdrawn 15/04/2017 9/01/2019 NA NA Whipp & Bourne Great Britain Suitable for use in existing Whipp & Bourne installations only
00265 1 Century Yuasa Battery 6V Cell Substation control batteryElectrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017 UXH125-6 NA NA Century Yuasa Preferred battery for use within Substations due to standardisation.
00264 1 Century Yuasa 48V 3kW Battery Charger Substation 50V control battery chargerElectrical
NetworksAlan Keating Full Type Approval Approved 15/04/2017 NA NA Century Yuasa Shop drawing approval by MTM Engineering required prior to manufacture
00263 1 Century Yuasa 125V 3kW Battery Charger Substation 125V control battery chargerElectrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017 NA NA Century Yuasa Shop drawing approval by MTM Engineering required prior to manufacture
00262 1 Century Yuasa 110V 3kW Battery Charger Substation 110V control battery chargerElectrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017 NA NA Century Yuasa Shop drawing approval by MTM Engineering required prior to manufacture
00261 1 Balfour Beatty DCP106 Protection Relay DC Protection relay.Electrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017 NA NA Balfour Beatty To be used with UGL KDA DCCBs, or in other designs as approved by MTM Engineering.
00260 1 ABB VD4 24kV Indoor AC Switchgear Assembly Indoor 22kV Switchgear, Indoor 11kV SwitchgearElectrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017 NA NA ABB Shop drawing approval by MTM Engineering required prior to manufacture
00259 1 ABB R-MAG 27kV Outdoor ACCB Outdoor 22kV ACCB, Outdoor 11kV ACCBElectrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017 NA NA ABB Fort Mary Florida, Mexico Shop drawing approval by MTM Engineering required prior to manufacture
00258 1500mm2 Aluminium Unscreened 1.9/3.3kV Single Core
Cable1500V Negative Connections within substations and to negative pillars
Electrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017 NA NA General Cable
00257 1500mm2 Aluminium Unscreened 1.9/3.3kV Single Core
Cable1500V Negative Connections within substations and to negative pillars
Electrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017 NA NA Prysmian
00256 1500mm2 Aluminium Unscreened 1.9/3.3kV Single Core
Cable1500V Negative Connections within substations and to negative pillars
Electrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017 NA NA Olex
00255 1 500mm2 Aluminium Screened 1.9/3.3kV Single Core Cable 1500V DC connections within substations and to switch mastsElectrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017 NA NA General Cable
00254 1 500mm2 Aluminium Screened 1.9/3.3kV Single Core Cable 1500V DC connections within substations and to switch mastsElectrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017 NA NA Prysmian
00253 1 500mm2 Aluminium Screened 1.9/3.3kV Single Core Cable 1500V DC connections within substations and to switch mastsElectrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017 NA NA Olex
00252 1400mm2 Aluminium Unscreened 1.9/3.3kV Single Core
Cable1500V Negative Connections within substations and to negative pillars
Electrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017 NA NA General Cable
00251 1400mm2 Aluminium Unscreened 1.9/3.3kV Single Core
Cable1500V Negative Connections within substations and to negative pillars
Electrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017 NA NA Prysmian
00250 1400mm2 Aluminium Unscreened 1.9/3.3kV Single Core
Cable1500V Negative Connections within substations and to negative pillars
Electrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017 NA NA Olex
00249 1 400mm2 Aluminium Screened 1.9/3.3kV Single Core Cable 1500V DC connections within substations and to switch mastsElectrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017 NA NA General Cable
00248 1 400mm2 Aluminium Screened 1.9/3.3kV Single Core Cable 1500V DC connections within substations and to switch mastsElectrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017 NA NA Prysmian
00247 1 400mm2 Aluminium Screened 1.9/3.3kV Single Core Cable 1500V DC connections within substations and to switch mastsElectrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017 NA NA Olex
00246 1185mm2 Aluminium Conductor, XLPE Insulated, Screened,
PVC/HDPE Sheathed 12.7/22(24)kV Three Core Cable22kV Cabling
Electrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017 NA NA General Cable
00245 1185mm2 Aluminium Conductor, XLPE Insulated, Screened,
PVC/HDPE Sheathed 12.7/22(24)kV Three Core Cable22kV Cabling
Electrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017 NA NA Prysmian
00244 1185mm2 Aluminium Conductor, XLPE Insulated, Screened,
PVC/HDPE Sheathed 12.7/22(24)kV Three Core Cable22kV Cabling
Electrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017 NA NA Olex
00243 195mm2 Copper Conductor, XLPE Insulated, Screened,
PVC/HDPE Sheathed 12.7/22(24)kV Single Core Cable22kV Cabling within substations
Electrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017 NA NA General Cable
00242 195mm2 Copper Conductor, XLPE Insulated, Screened,
PVC/HDPE Sheathed 12.7/22(24)kV Single Core Cable22kV Cabling within substations
Electrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017 NA NA Prysmian
00241 195mm2 Copper Conductor, XLPE Insulated, Screened,
PVC/HDPE Sheathed 12.7/22(24)kV Single Core Cable22kV Cabling within substations
Electrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017 NA NA Olex
00240 1 3MW UGL Rectifier with integrated Rectifier Control System 1500V 3MW Class VI RectifierElectrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017 NA NA UGL Sydney Shop drawing approval by MTM Engineering required prior to manufacture
00239 1 3220kVA TMC Dry Rectifier Transformer Rectifier Transformer for use with 1500V 3MW Class VI RectifierElectrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017 NA NA TMC Melbourne Shop drawing approval by MTM Engineering required prior to manufacture
00238 1 22kV/415V TMC Dry Auxiliary Transformer (50kVA) Substation Auxiliary Transformer - Supply of Substation Lighting and Power OnlyElectrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017 NA NA TMC Melbourne Shop drawing approval by MTM Engineering required prior to manufacture
00237 1 22kV/415V Etel Oil Auxiliary Transformer (50kVA) Substation Auxiliary Transformer - Supply of Substation Lighting and Power OnlyElectrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017 NA NA Etel New Zealand Shop drawing approval by MTM Engineering required prior to manufacture
00236 1 22kV/230V TMC Dry Auxiliary Transformer (50kVA) Substation Auxiliary Transformer - Supply of Substation Lighting and Power OnlyElectrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017 NA NA TMC Melbourne Shop drawing approval by MTM Engineering required prior to manufacture
Please refer to L1-CHE-PRO-004 for T.A Procedure
Uncontrolled if printed. Controlled by MTM Eng. Systems (OCE)
Page 15 of 22 [email protected]
Metro Trains Melbourne Engineering Approved Product List As of 20/01/2020 (Updated monthly)
TA
NumberIssue Title/Product Function/Application(s)
Applicable
System(s)SME Approval Type Approval Status
Approval/Rejected
DateExpiry
Withdrawal/Suspension
DateType/Model Number
Hardware
Revision No.
Software Version
No.Manufacturer Place of Manufacture Condition and Service Restrictions
00235 1 22kV/230V Etel Oil Auxiliary Transformer (50kVA) Substation Auxiliary Transformer - Supply of Substation Lighting and Power OnlyElectrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017 NA NA Etel New Zealand Shop drawing approval by MTM Engineering required prior to manufacture
00234 1 22kV/2200V TMC Dry Signal Transformer (50kVA/63kVA) Signal TransformerElectrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017 NA NA TMC Melbourne Shop drawing approval by MTM Engineering required prior to manufacture
00233 1 22kV/2200V Etel Oil Signal Transformer (50kVA) Signal TransformerElectrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017 NA NA Etel New Zealand Shop drawing approval by MTM Engineering required prior to manufacture
00232 1 22kV/1000V TMC Dry Signal Transformer (50kVA/63kVA) Signal TransformerElectrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017 NA NA TMC Melbourne Shop drawing approval by MTM Engineering required prior to manufacture
00231 1 22kV Surge Diverter - ABB Polim D Surge Diverter for use on 22kV outdoor buses at substationsElectrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017
POLIM-D26, 32.5kV rms
ABB Part: 7840064NA NA ABB Engineering review of insulation coordination required.
00230 1 22kV Isolator 11kV or 22kV exposed bus isolator for use within substationsElectrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017
Single Phase Hookstick
Operation. 12/24KV, 630A HVI
Part Number 70423-3MT
NA NA NGK Stanger
00229 1 22kV Fuse Isolator 11kV or 22kV exposed bus fuse isolator for use within substationsElectrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017
Single Phase Hookstick
Operation 12/24kV, 150kV BIL
Part Number 72298/17MT2
NA NA NGK Stanger
Selection of fuse with appropriate rating to be undertaken by competent engineer and approved
prior to installation
Prospective fault level not to exceed 6kA
00228 1 22kV Fuse Isolator 11kV or 22kV exposed bus fuse isolator for use within substationsElectrical
NetworksAlan Keating Grandfather Rights Approved 15/04/2017
V Series EDO
Model V150PC6S0000NA NA ABB
Selection of fuse with appropriate rating to be undertaken by competent engineer and approved
prior to installation
Prospective fault level not to exceed 6kA
00227 1 HAZS Disconnector UGL Off-load switching of DC systems, such as railway networks.Electrical
SystemsGeorge Marulli Full Type Approval Withdrawn NA HAZS Range 2.4kA DC NA NA Mersen Europe
00226 1 HV Terminations Medium and low voltage terminations and joints for traction and 581V Anode circuitsElectrical
SystemsGeorge Marulli Full Type Approval Withdrawn NA
H6i500MT01
H6I500BLMT03
H6ON500BLMT02
H6N500BLMT04
NA NA Hongshang China
00225 1TMC 3.3kV/2.2kV/110V Single Phase Signal Load
Transformers
Supply of 110V signalling loads from the 3.3kV, or alternatively the 2.2kV, Essential Services Distribution SystemTMC 3.3kV/2.2kV/110V Single
Phase Signal Load Transformers
Electrical
SystemsAlan Keating Provisional Type Approval Approved 7/06/2017 6/06/2018
TMT120033322C (3kVA)
TMT120063322C (6kVA)
TMT120103322C (10kVA)
TMT120153322C (15kVA)
NA NATransformers Manufacturing
Company (TMC)Australia
To be used in conjunction with a Trackside Essential Services Switchgear Assembly conforming to
MESP 041000-01
Satisfactory completion of Type Testing and Routine Testing on a unit (any variant listed) to AS
00224 1 SCALANCE Industrial Ethernet switches Industrial Ethernet switched for networks at data transfer rates of 10/100/(1000) Mbps in a line, star or ring topology. Structures Peter Dohle Full Type Approval Approved 20/07/2017 6GK5206-2BS00-2AC2 1 1 Siemens Germany
1.Purchasing:
Scalance switches shall be procured with C-PLUG dongles.
2. Deployment:
2.1 FMP shall be configured when using fibre SFPs.
00223 1 SIMATIC HMI ComfortSIMATIC HMI devices offer the option of local operation of ventilators or other system components
Structures Peter Dohle Full Type Approval Approved 20/07/2017 TP1500 NA Windows CE V6.0 Siemens Germany
1. Implementation of security recommendations in accordance with Siemens document “Security
guidelines for SIMATIC HMI devices”, particularly:
1.1 Panel access protection
A password shall be implemented to protect access to the panel device settings (section 1.3.1).
00222 1 Multi-Point Aspirating Smoke Detection System (MASDS)
Data Centres, Sub-stations, Concourse and Platforms, Service Tunnels and Train Carriages
VESDA within Metro or Rail applications is synonymous to protection of critical assets and enabling safe evacuation of people in the event of a
fire. Structures Lachlan Henderson Full Type Approval Approved 8/08/2017 VESDA-E VEU NA NA Xtralis Malaysia
• The VESDA-E VEU series aspirated detector shall be supplied with an aluminium enclosure.
• Provision of spare components, materials and special tools shall be agreed with MTM
infrastructure on a case by case basis.
• Requirements for maintenance given in manufacturer’s O & M documentation shall be
00221 1 Texlon ETFE Roofing System Roof Skylight Structures Louis Knap Engineering Product Approval Approved 23/06/2017 LK-700 NA NA Vector Foiltec Germany & China
Vector Foiltec is to provide an Operation and Maintenance Manual for the Texlon ETFE roofing
system. The Manual must detail equivalent products that are freely available from alternative
suppliers for all components. It shall also include work instructions for repairs to the system.
00220 1 Continuity to Rail MonitorThe application of this equipment is limited to the operation of the Remote Isolation System. There are no other applications for this equipment
outside of switching activities.
Electrical
SystemsCraig Tooke Provisional Type Approval Approved 16/10/2017 15/10/2018
• IFS-220001-1 Continuity to Rail,
Control Unit
• IFS-220001-2 Continuity to Rail,
Sensor
NA NA Infraco Systems Australia
00219 1 Remote Isolation System: CRS2000 Voltage SensorThe application of this equipment is limited to the operation of the Remote Isolation System. There are no other applications for this equipment
outside of switching activities.
Electrical
SystemsWesley Allen Provisional Type Approval Approved 29/06/2017 29/06/2018 CRS2000+CBI21CA-24VDC NA NA PROAT Spain
The unit shall be used in conjunction with all type approved equipment as part of the Remote
Isolation System in conformance with L1-CHE-SPE-128.
Satisfactory detailed design package (shop drawings) shall be approved by MTM Engineering.
00218 1
161mm2 Contact Wire
181mm² Catenary Wire
9.6mm² Dropper Wire
For use on the 1500V overhead traction wiring system. Structures Izy Perona Full Type Approval Approved 5/06/2017
161mm2 Contact Wire
181mm² Catenary Wire
9.6mm² Dropper Wire
N/A N/A NKT Cables Germany
• There shall be no joints in the contact or catenary wires. This includes joints being made in the
raw material prior to drawing.
• Country of manufacturer to remain in Germany.
00217 1TMC Cast resin Dry Type Transformer
22000/581-581V Dd0y11 AN IP43
22000/581-581V Dd0y11 AN IP43
Traction Converter TransformerStructures Alan Keating Full Type Approval In Progress TMT034MW22 N/A N/A TMC Australia
00216 1 Dampers
Tunnel Ventilation systems with considerable global application experience. Used in Australia on Cross City Tunnel, Sydney, M5 Road Tunnel,
Sydney, Metro Rail, Perth, Lane Cove Tunnel, Sydney, Melbourne East Link Tunnel, Parrametta Rail Link, Sydney, Inner Northern Busway,
Brisbane, Legacy Way Tunnel, Brisbane, City Link Tunnel, Melbourne.
Structures Lachlan Henderson Full Type Approval Superseded 8/08/2017
JFM / E / FL2 / x / x / x / x / x / x /
x / x / Z04
JFM / E2 / FL2 / x / x / x / x / x / x /
x / x / Z04
N/A N/A TROX Malaysia
Electrically Actuated JFM Dampers (‘Z04’)
It is recommended that type approval is issued for TROX “JFM series” tunnel ventilation dampers of
the following part number designations (note: x = no specific requirement):
JFM / E / FL2 / x / x / x / x / x / x / x / x / Z04
00216 2 Dampers
Tunnel Ventilation systems with considerable global application experience. Used in Australia on Cross City Tunnel, Sydney, M5 Road Tunnel,
Sydney, Metro Rail, Perth, Lane Cove Tunnel, Sydney, Melbourne East Link Tunnel, Parrametta Rail Link, Sydney, Inner Northern Busway,
Brisbane, Legacy Way Tunnel, Brisbane, City Link Tunnel, Melbourne.
Structures Lachlan Henderson Full Type Approval Approved 23/08/2017
JFM / E / FL2 / x / x / x / x / x / x /
x / x / Z04
JFM / E2 / FL2 / x / x / x / x / x / x /
x / x / Z04
N/A N/A TROX Malaysia
Electrically Actuated JFM Dampers (‘Z04’)
It is recommended that type approval is issued for TROX “JFM series” tunnel ventilation dampers of
the following part number designations (note: x = no specific requirement):
JFM / E / FL2 / x / x / x / x / x / x / x / x / Z04
00215 1 Programmable Logic Controller
High-end process control (e.g. power generation, utilities), machine control and critical infrastructure applications (e.g. tunnels, data centres,
hospitals), where high availability (>99.99%) is required. Can also be used for safety applications up to SIL 3 (TUV certified product to
IEC61508)
Structures Lachlan Henderson Full Type Approval Approved 20/07/2017 N/A N/A Siemens GermanyProjects installing the S7-400 PLC will ensure that the devices are integrated into existing
maintenance arrangements and sufficient schedule 4 budget allocated for their lifecycle.
00214 1 Witt & Sohn Reversible Axials (MR Series)
Reversible axial fan complete with special corrosion resistant cast aluminium with inner steel skeleton impeller blade design suited for high
temperature and heavy industrial applications.
Independently laboratory certified for temperature rating upto 400degC/2 hours.
Structures Lachlan Henderson Full Type Approval Approved 8/08/2017Witt & Sohn Reversible Axials
(MR Series)N/A N/A Witt & Sohn Germany
A-MR x / x / x / x /x
On the conditions that:
1. A (as in A-MR) is an adapted fan designed for high temperature applications, specifically 400°C
for 2 hours.
00213 1 EWSMany existing applications include but not limited to: Hospitals, High rise buildings, University complexes, Casinos, Road Tunnels, Commercial
buildings, shopping centres, and defence facilitiesStructures Lachlan Henderson Full Type Approval Approved 8/08/2017 N/A N/A Tyco Fire Protection New Zealand
1. Provision of spare components, materials and special tools shall be agreed with MTM
Infrastructure on a case by case basis.
2. Requirements for maintenance given in manufacturer’s O&M documentation shall be
incorporated into MTM maintenance procedures.
00212 1 FireMaster - Smoke Curtain Fire Compartmentation / Smoke Compartmentation for all buildings Structures Lachlan Henderson Full Type Approval Approved 11/07/2018 Coopers "FireMaster S" N/A N/A Coopers Fire UK/Australia
00211 1 Traction Return Bonding Cable
For use in the Train traction return system of the MTM Melbourne network, as traction return cabling for the 1500 volts DC return. It is used as
cabling connected to; impedance bonds, negative return pillars and connected to substation negative traction return, as temporary jumper cables
in rail replacement activities and to jumper out insulated rail joints for specific applications
Signals Jim Warwick Full Type Approval Approved 1/05/2017 300mm2 Aluminium N/A N/A South Korea
That the cable be supplied in accordance to VRIOGS specifications with the only exceptions being:
1) that the type insulation produced and used be HD-90-CPE
2) And that the cable be supplied on 500 meter drums rather than the 250 meter drums specified in
VRIOGS 012.6.34
00210 1 Star Quad CableFor use in the Signalling and also Communications sections of Metro Trains Melbourne-MTM for applications such as ; train detection systems
cabling (axle counters, CSEE jointless track circuits, etc), signal post telephones, and similar such applicationsSignals Jim Warwick Full Type Approval Approved 1/05/2017
0.90mm 2 pair quad
communications cableN/A N/A Germany There are no conditions to the Type Approval of this cable
00209 1 Infraco SystemsThe application of this equipment is limited to the operation of the Remote Isolation System. There are no other applications for this equipment
outside of switching activities.
Electrical
SystemsGeorge Marulli Full Type Approval Approved 6/06/2017 MR41E Motor Drive N/A N/A France
To be used in conjunction with all type approved equipment as part of the Remote Isolation System
in conformance with L1-CHE-SPE-128.
Satisfactory detailed design package (shop drawings) to be approved by MTM Engineering.
00208 1Remote Isolation System – SBE 1500V 4000A Disconnector
and Earthing SwitchThe application of this equipment is to conduct isolation and short circuiting of the 1500V DC Overhead Network. Overhead Ashley Keep Provisional Type Approval Approved 15/06/2017 14/06/2018
SBE 1500V 4000A Disconnector
and Earthing SwitchN/A N/A SDCEM France
• Switch shall be used in conjunction with all type approved equipment as part of the Remote
Isolation System in conformance with L1-CHE-SPE-128.
• Satisfactory detailed design package (shop drawings) shall be approved by MTM Engineering.
• Standard drawings for product shall be produced in PTV compliant format and booked into DMS.
00207 1 Urbanise IoT Sensors and Gateway
Remote monitoring of building assets, assets movement, environmental conditions and
to improve the maintenance and operation of buildings. The Remote Monitoring Platform provides the ability for an end user customer to view
the data represented as trends or alarms and conditions of the building
assets.
OCS Peter Dohle Engineering Product Approval Approved 03/30/2017
- Wireless M2M Gateway - UBG-
4-3C3I-SC-B1-ND
- Meter Counter - UBS-4-W1-DC-
PC-03-MC
N/A N/A Urbanise
Housing: Manufactured in
China
Final assembly: USA
Three parallel activities are proposed:
1. Conduct a two month trial (expires 02/06/2017) of the Urbanise IoT system at Surrey Hills
Railway No type approval for wider use on the network is granted.
2. System elements shall not to be installed in vicinity of CSEE track circuits without further testing.
00206 153kg 4 hole insulated fishplate (modified from 6 hole
insulated fishplate)
Modified Westray 4 hole insulated fishplate will be used at locations, particularly within P&Cs, where 6 hole fishplates cannot fit. MTM currently
uses 1939 Victorian Railways 4 hole Mechanical IRJ at these locations. MTM to supply own insulation kit for installation of joint dependent on a
dry run off track to determine compatibility.
Track Alan Keating Full Type Approval Approved 21/04/2017 CP522-1 N/A N/A Westray Engineering Australia
1. 4 hole Westray insulated fishplate is to be installed with existing insulation kits in use on MTM
network
2. 4 hole Westray insulated fishplate is to comply with requirements of AS 1085.2-2002 Railway
track material Part 2: Fishplates
00205 1 UGL LED Tricolour Signal To be used as another option for installation in situations where LED modules are installed. Signals Alan Keating Full Type Approval Approved 28/08/2017 N/A N/A UGL Mexico
1) When a UGL MK3 Tricolour LED TC2 Signal Module Version 10A is installed on a signal post
with 212mm A and B arms, both arms shall have the same signal model installed. This is to provide
consistent signal luminance of signals on the same post.
2) Where UGL becomes aware of any unsafe failure modes (i.e. any mode which may compromise
00204 1 Weidmuller PROmax 960W 24V 40A
This supply has a smoother and better regulated output than the current Ironcore solution which it is replacing. It is also smaller, which offers
increased design utility and decreased manual handling risk. Additionally, it is far cheaper than the Ironcore solution.
For use with Siemens S-40 and S-60 Boom Mechanisms alongside the accompanying Siemens DC/DC converters.
Signals Alan Keating Full Type Approval Approved 24/07/2017 N/A N/A Weidmuller Germany
References contained within these conditions are made to "Full Type Approval Report Weidmuller"
version 1 dated 21/07/2017.
1) The user shall ensure that he/she is fully aware of and complies with the information given in
"Weidm0llerPROmax 960W 24V 40A Operating Instructions".
00203 1 Multiduct - HDPE based troughing system Mounting to structures for Combined Service Route.Electrical
NetworksGeorge Marulli Full Type Approval Approved 28/03/2018 N/A N/A Cubis Systems Ireland
• The Multiduct product is only to be used over bridges
• The Multiduct product requires the endorsement for use in each location by the Chief Engineer
• Ensure that the pits on either side of the bridge and to which the Multiduct enters are the standard
pits used by MTM
00203 2 Multiduct - HDPE based troughing system Installation of Combined Service Route compact multi chamber troughing system for above ground applications.Electrical
NetworksAlan Keating Full Type Approval Approved 4/04/2017 N/A N/A Cubis Systems Ireland
• The MULTIduct product shall be used for bridge crossings ONLY
• Pits shall be provided on either side of the bridge
• Pits shall be MTM approved
• Ensure “Danger HV” label/s shall be securely placed on every section carrying HV cables
00203 3 Multiduct - HDPE based troughing system Installation of Combined Service Route compact multi chamber troughing system for above ground applications.Electrical
NetworksAlan Keating Full Type Approval Approved 28/03/2018 N/A N/A Cubis Systems Ireland
• The MULTIduct product shall be used for above ground installations ONLY.
• Transition adaptor may be installed up to 500mm below the ground surface.
• Pits shall be provided on either side of the transition.
• Entry to pits shall be by conduit only.
00202 1 Chemset Reo 502
It is to be used for fastening the sleeper anchor bolts in the MURL.
Can also be used for reinforcing bars, deformed bars, starter bars, anchoring structural steel to concrete, rail sleeper repair, rail gantries, road
stitching, light poles
Signals Jim Warwick Engineering Product Approval Approved 28/08/2017 N/A N/A N/A Ramsetreid Australia
• Application and Handling of Chemset Reo 502 shall be in accordance with Manufacturer’s
instructions. Refer to Chemset Reo 502 Technical Data Sheet and Chemset Reo 502 Material
Safety Data Sheet.
• Chemset Reo 502 shall be utilised for anchoring hold-down bolts in both direct fixation and double
00201 1 Westinghouse S40 Boom Mechanism TBC Signals NA Under Development Registered NA NA
00200 1External Mount & Integral Camera Lowering Device (CLD)
CCTV Pole (Customised & External Retrofit)
Can be used with any new CCTV installations and most existing CCTV around the network.
Areas of application:
- External retrofit to existing infrastructure for existing/new CCTV
- Installed with a customised steel or concrete pole for new CCTV
OCSJohn Dauth & Peter
DohleEngineering Product Approval
Suspended (Until Further
Notice)N/A N/A
CCTV Lowering System: MG
Squared
Poles (for Australia):
USA & Australia
00199 1 GRC Use as edge profile cladding on the outside of the viaduct in all areas on LXRP-CTD. Structures John Dauth Engineering Product Approval Withdrawn N/A N/A 25/01/2018 N/A N/A N/A
ASURCO Contracting Pty
Ltd & GRC Environments
Pty Ltd
Australia
00198 1 RMP Use as edge profile cladding on the outside of the viaduct in all areas on LXRP-CTD. Structures John Dauth Engineering Product Approval Approved 8/02/2017 N/A N/A N/AViscount Rotation Moulding
Pty LtdAustralia
Please refer to L1-CHE-PRO-004 for T.A Procedure
Uncontrolled if printed. Controlled by MTM Eng. Systems (OCE)
Page 16 of 22 [email protected]
Metro Trains Melbourne Engineering Approved Product List As of 20/01/2020 (Updated monthly)
TA
NumberIssue Title/Product Function/Application(s)
Applicable
System(s)SME Approval Type Approval Status
Approval/Rejected
DateExpiry
Withdrawal/Suspension
DateType/Model Number
Hardware
Revision No.
Software Version
No.Manufacturer Place of Manufacture Condition and Service Restrictions
00197 1 FireMaster Fire Compartmentation / Smoke Compartmentation for all buildings Structures John Dauth Full Type Approval Withdrawn N/A N/A NA FM N/A N/A Coopers Fire UK & Australia
00196 1 Siemens Helios Sine Wave Inverter Used to provide 110V clean power for Westrace MkII LOM Cards Signals Russell Shield Full Type Approval Approved 16/01/2017 RSI 200-2A50F3P-S8347 NA NA
Helios Power Solutions P/L
Unit 6 / 2-8 South St,
Rydalmere NSW 2114
Helios Power Solutions P/L Refer to Type Approval Certificate
00195 1 Siemens IOT2040The IOT2040 will be used to interface S7-1200 PLCs to provide state of station devices such as pumps, lifts, lights, gates, etc. back to operators
at the local and remote station via existing operator interfaces, such as DVTel.OCS Peter Dohle Engineering Product Approval Approved 7/02/2018 IOT2040 N/A N/A Siemens China
00194 1 S7 1200 Series PLCThe S7-1200 series of PLC and associated basic HMI panels are to be used for local and remote control of station equipment such as gates,
pumps, lift status, etc.OCS Peter Dohle Engineering Product Approval Approved 7/02/2018 Various N/A N/A Siemens China
00193 1 Phoenix 48v-24v DC-DC 5A.
The QUINT-PS/48DC/24DC/ 5 is a DC-DC converter which allows connection of 24vDC powered devices to 48vDC sources.
It is physically compact, DIN mountable, and provides an isolated 24vDC/5A source at temperatures up to 60 degrees Celsius, and 24vDC/3.7A
at 70 degrees.
OCS Peter Dohle Engineering Product Approval Approved 7/02/2018 QUINT-PS/48DC/24DC/ 5 N/A N/A Phoenix Contact China
00192 1 161mm2 Hard-drawn Copper Contact WireContact wire is used to provide traction power to the trains. The contact wire manufactured by Isodraht is identical to the contact wire MTM have
been using since the 1910’s. Isodraht will be used as an alternative manufacturer to the MTM’s existing supplier Lamifil.Overhead Izy Perona Full Type Approval Approved 30/03/2017 N/A N/A Isodraht GmbH Germany
00191 1 Pfisterer TENSOREX Tensioner C+
The Tensioner C+ manufactured by Pfisterer is an overhead wiring spiral spring based tensioning device which applies a constant tension to the
overhead conductors throughout a given temperature range. The Tensioner C+ performs the same function as the existing balanced weight
wheel assembly and will be used as an alternative product.
Overhead Izy Perona Provisional Type Approval Approved 4/07/2018
000700434-DB1203
000700433-DB1203 N/A N/A Pfisterer Germany
Temperature range shall be between 0°c and 60°c
Half tension length shall not exceed 700m.
Shall be installed at the following locations:
2off at WA591+34 on the Altona Loop
00191 2 Pfisterer TENSOREX Tensioner C+
The Tensioner C+ manufactured by Pfisterer is an overhead wiring spiral spring based tensioning device which applies a constant tension to the
overhead conductors throughout a given temperature range. The Tensioner C+ performs the same function as the existing balanced weight
wheel assembly and will be used as an alternative product.
Overhead Izy Perona Provisional Type Approval Approved 3/07/2018
750/2000 4S, part number
000700434-DB1203
750/1500 3S, part number
000700433-DBS1203
N/A N/A Pfisterer Germany
• Shall be used in locations where it can be demonstrated that weight wheel assemblies will be a
safety hazard or the structure space prevents the use of weight wheel assemblies.
• Spare units shall be stored as per the manufactures recommendations.
• All units shall be delivered with a “Zebra’ aluminium position label and bolted stainless steel
00191 3 Pfisterer TENSOREX Tensioner C+
The Tensioner C+ manufactured by Pfisterer is an overhead wiring spiral spring based tensioning device which applies a constant tension to the
overhead conductors throughout a given temperature range. The Tensioner C+ performs the same function as the existing balanced weight
wheel assembly and will be used as an alternative product.
Overhead Izy Perona Full Type Approval Approved 6/03/2019 NA
750/2000 4S, part number
000700434-DB1203
750/1500 3S, part number
000700433-DBS1203
N/A N/A Pfisterer Germany
00190 1 THYCON MPX Industrial UPS
The MPX UPS comprises the following major components:
• Input Circuit Breaker – this provides the point of isolation & protection to the rectifier.
• Rectifier – converts the incoming AC to DC. It supplies DC power to the Inverter and to the battery bank.
• Battery Circuit Breaker – this provides a point of isolation between the battery bank and the Inverter/Rectifier. The battery circuit breaker
includes an automatic under voltage release that isolates the batteries whenever the inverter is shutdown.
• Battery Bank – this provides the energy for the UPS inverter to survive disturbances to the incoming AC mains supply.
• Inverter – to convert DC to AC power
• Reactive Compensator – to provide reactive power
• Dzn0 Output Transformer – this provides galvanic isolation between the UPS Inverter and the output supply. It provides a clean neutral for the
UPS load, while prevent balanced triplen harmonic currents from returning to the input.
• Output Circuit Breaker – this provides protection to the UPS inverter in the event of a fault.
• Static Switch – this ensures supply is maintained in the event of a Inverter fault. It also provides an alternative source of fault energy to clear
downstream load faults.
Substations Alan Keating Provisional Type Approval Approved 4/08/2017 20/07/2018 MPX 50 through to MPX 200 N/A N/A Thycon Australia
Synchronisation input shall be provided in accordance with MTM requirements to permit paralleling
(normal switching practice).
Unit shall be configured such that when no synchronisation reference is available the load is
dropped, subject to a site specific risk assessment.
Independent sync-check protection shall be provided
Shall be used in conjunction with an Auxiliary and Essential Services Transformer in conformance
with MESP 050100-01.
Satisfactory detailed design package (shop drawings) shall be approved by MTM Engineering.
Standard drawings for product shall be produced in PTV compliant format and booked into DMS.
Sound level testing shall be completed by independent body and results to confirm performance is
in line with specification.
Testing of Short Circuit Performance shall be undertaken on the first unit of each type.
Batteries shall be installed within climate controlled rooms to ensure an ambient temperature of
25±5°C.
Field testing for compatibility with existing equipment and synchronisation solution shall be
completed prior to use of the equipment during normal running.
MTM maintenance and operating documentation shall be produced prior to commissioning.
An Inspection and Testing Plan for the installation of unit shall be approved by MTM Engineering.
Hardware and software versions used during commissioning testing shall be recorded and shall not
be changed without the consent of MTM Engineering.
00190 2 THYCON MPX Industrial UPS
The MPX UPS comprises the following major components:
• Input Circuit Breaker – this provides the point of isolation & protection to the rectifier.
• Rectifier – converts the incoming AC to DC. It supplies DC power to the Inverter and to the battery bank.
• Battery Circuit Breaker – this provides a point of isolation between the battery bank and the Inverter/Rectifier. The battery circuit breaker
Substations Craig Tooke Full Type Approval Approved 14/06/2019
MPX 100 AX00010207
MPX 150 AX00010208
MPX 200 AX00010209
MPX 108 AX00010222
N/A N/A Thycon Australia
• Synchronisation input shall be provided in accordance with MTM requirements to permit
paralleling (normal switching practice).
• The UPS shall not be utilised in areas with phase sensitive signalling equipment without further
00189 1 3KV Stand off Post Insulator
Electrical Characteristics: Voltage rating – 3.6KV (Required voltage Level -3KV min)
Impulse withstand voltage – 45KV (required-19KV minimum)
Dry Power Frequency withstand voltage -20KV (req.-7KV min)
Wet Power Frequency withstand voltage- 16KV (req.-7KV min)
Overhead Izy Perona Full Type Approval Withdrawn 18/09/2018 BBI 75-16-16 N/A N/A EMC Pacific Pty. Ltd -
00188 1Three Phase Essential Services Load Transformer
3300/400V AC
Supply of 400V Essential Services loads (as defined in L1-CHE-SPE-154) from the 3.3kV Essential Services Distribution System when
connected to Essential Services Trackside Switchgear conforming to MESP 041000-01 and mounted within a suitable secured and
weatherproof enclosure or building.
Substations Alan Keating Provisional Type Approval Approved 28/11/2017 27/11/2018
TMT130063300B (6kVa 3.3kV)
TMT13010330B (10kVA 3.3kV)
TMT130203300B (20kVA 3.3kV)
TMT130323300B (31.5kVA 3.3V)
N/A N/A TMC Australia
Satisfactory detailed design package approved by MTM Engineering including completed technical
data schedule, shop drawings and precise nameplate details.
Type tests as specified in AS60076 conducted and results approved by MTM Engineering.
00187 1 Emsys Cellspy Battery Monitoring System for Substation
Control Batteries
This product allows continuous remote condition monitoring of substation batteries. These batteries are critical to ensuring the operation of the
substation and are regularly inspected. Condition monitoring will allow trending and potential to reduce or remove inspections by maintenance
staff in future.
Substations Craig Tooke Engineering Product Approval Withdrawn 11/10/2019
CSPY-200-0 (Battery monitor)
WDCM-300 (Bus Monitor)
SRV-100 (Mini Gateway)
3G-GSM-Modem (Modem)
N/A N/A Emsys Design Inc Australia
00186 1 Single Phase Signal Power Supply TransformersSupply of 110V signalling loads from the 3.3kV Essential Services Distribution System when connected to Essential Services Trackside
Switchgear conforming to MESP 041000-01 and mounted within a suitable secured and weatherproof enclosure or building.Substations Alan Keating Provisional Type Approval Approved 28/11/2016 28/11/2018
TMT120033300A (3kVa 3.3kV)
TMT120063300A (6kVA 3.3kV)
TMT120103300A (10kVA 3.3kV)
TMT120153300A (15kVA 3.3kV)
N/A N/A TMC Australia
Satisfactory detailed design package approved by MTM Engineering including completed technical
data schedule, shop drawings and precise nameplate details.
Type tests as specified in AS60076 conducted and results approved by MTM Engineering.
00186 2 Single Phase Signal Power Supply TransformersSupply of 110V signalling loads from the 3.3kV Essential Services Distribution System when connected to Essential Services Trackside
Switchgear conforming to MESP 041000-01 and mounted within a suitable secured and weatherproof enclosure or building.Substations Craig Tooke Full Type Approval Approved 13/06/2018
TMT120033300A (3kVa 3.3kV)
TMT120063300A (6kVA 3.3kV)
TMT120103300A (10kVA 3.3kV)
N/A N/A TMC Australia NIL
00185 1
IEI Tank 820 PC - A durable fan-less Embedded PC
constructed of aluminium alloys and designed with various
expansion interfaces, giving the ability to add PCI/PCIe
expansion boards.
The product will be utilised as a fan-less PC for the TCMS Fringe Box applications. While the product is capable of operation as a fan-less PC
for other purposes, other uses will require amendment to the Type Approval.OCS Peter Dohle Engineering Product Approval Approved 7/12/2016 TANK-820-H61-i5/2G/1P2E-R22 N/A N/A IEI USA Intended Application -OCS Signalling Networks- TCMS Fringe Box Applications.
00184 1Schneider Premset Essential Services Distribution System
Switchgear
Protection and switching of Essential Services Distribution System feeders and supply transformers when used in conjunction with an
appropriate SCADA control system and installed within a substation.Substations Alan Keating Provisional Type Approval Superseded 30/11/2016 30/05/2018 D06H, I06T, G06, D06H-NE N/A N/A Schneider France
Satisfactory detailed design package to be completed and approved by MTM Engineering.
Submission of compliance statement relating to no requirement for arc venting at 2kA fault levels.
Standard drawings for each panel type to be produced in PTV compliant format and booked into
DMS.
Sleeved cable markers to be provided on cables within the control compartment.
Hooks or clips for storage for operating handle to be provided near to switchgear.
00184 2Schneider Premset Essential Services Distribution System
Switchgear
Protection and switching of Essential Services Distribution System feeders and supply transformers when used in conjunction with an
appropriate SCADA control system and installed within a substation.Substations Alan Keating Provisional Type Approval Approved 20/08/2018 1/03/2019 D06H, I06T, G06, D06H-NE N/A N/A Schneider France
Satisfactory detailed design package to be completed and approved by MTM Engineering.
Submission of compliance statement relating to no requirement for arc venting at 2kA fault levels.
Standard drawings for each panel type to be produced in PTV compliant format and booked into
DMS.
00183 2Eaton Xiria Essential Services Distribution System
SwitchgearSupply of 3.3kV Essential Services Distribution System via a compatible step up transformer Substations Alan Keating Provisional Type Approval Superseded 13/09/2017 30/11/2018 TBA N/A N/A Eaton Germany
Confirmation of desired standard 3 way bus configuration during detailed design process.
Installation of switchgear assembly to be such that access to the rear is prevented during operation.
Installation to be restricted to locations where the maximum prospective fault current is no more
than 2000A.
00183 3Eaton Xiria Essential Services Distribution System
Switchgear
Supply of 3.3kV Essential Services Distribution System via a compatible step up transformer
For Trackside Installation Purpose
Substations Alan Keating Provisional Type Approval Approved 20/08/2018 31/12/2018 TBA N/A N/A Eaton Germany
Confirmation of desired standard 3 way bus configuration during detailed design process.
Installation of switchgear assembly to be such that access to the rear is prevented during operation.
Installation to be restricted to locations where the maximum prospective fault current is no more
than 2000A.
00183 4Eaton Xiria Essential Services Distribution System
Switchgear
Supply of 3.3kV Essential Services Distribution System via a compatible step up transformer
For Trackside Installation Purpose
Substations Craig Tooke Full Type Approval In Progress3.3KTK-METRO-6KVA
3.3KTK-METRO-10KVA N/A N/A Eaton Germany
00182 1AEG Protect 8.33 Essential Services Distribution System
Supply UPSSupply of 3.3kV Essential Services Distribution System from 400V UPS output. Substations Alan Keating Provisional Type Approval Approved 30/11/2016 30/05/2018
70151774/001 (Protect 8.31 20-
400-216-230)
70152034/002 (Protect 8.33 40-
400-384-400)
NA NA AEG Power Systems Germany
Synchronisation R&D completed successfully or clarification of existing synchronisation
functionality.
Satisfactory detailed design package to be completed and approved by MTM Engineering
Standard drawings for product to be produced in PTV compliant format and booked into DMS.
00182 2AEG Protect 8.33 Essential Services Distribution System
Supply UPSSupply of 3.3kV Essential Services Distribution System from 400V UPS output. Substations Craig Tooke Provisional Type Approval Approved 28/11/2016 28/05/2018
Protect 4.33-60kVA
Protect 4.33-120kVA
Protect 4.33-180kVA
Product 4.33-220 kVA
NA NA AEG Power Systems Germany
Where phase dependent signal equipment is present this equipment shall only be placed into
service when installed with independent check sync protection relay and with external
synchronisation available. The unit shall always be installed with the AEG proprietary LBS included.
00181 1 400V/3.3kV Essential Services Step-up Transformer Suitable for cable entry and exit, indoor or outdoor installation. Substations Alan Keating Provisional Type Approval Approved 30/11/2016 30/05/2018
TMT110603300 (60kVA)
TMT111203300 (120kVA)
TMT111803300 (180kVA)NA NA TMC Australia
Satisfactory detailed design package approved by MTM Engineering including shop drawings and
precise nameplate details.
Type tests as specified in AS60076 conducted and results approved by MTM Engineering.
00180 1 22kV/400V Essential Services and Auxiliary Transformer Supply of Essential Services UPS and auxiliary loads from 22kV supply within a substation or switchyard. Substations Alan Keating Provisional Type Approval Approved 30/11/2016 30/05/2018
31727 (100kVa, 22kV)
31730 (200kVa, 22kV) NA NA TMC Australia
Alteration of winding vector to Dyn1 in GA drawing title blocks.
Provision of completed Technical Data Schedules for the transformers and acceptance of these
schedules as appropriate.
00179 13.8/6.6 kV 3 core - 35mm2 Copper Conductor
XLPE Insulated cable35mm
2 Cable for 3.3kV Essential Services Distribution System Substations Alan Keating Full Type Approval Approved 30/11/2016 XHHP18RD003OMAA NA NA Nexans (Olex) China The Manufacturer is to label each core with the numbers 1, 2, and 3 or R, W, and B.
00178 13.8/6.6 kV 3 core - 35mm2 Copper Conductor
XLPE Insulated cable35mm
2 Cable for 3.3kV Essential Services Distribution System Substations Alan Keating Full Type Approval Approved 30/11/2016 14317111.01 NA NA Prysmian Group Australia The Manufacturer is to label each core with the numbers 1, 2, and 3 or R, W, and B.
00177 1 Forked Collar SocketThe forked collar sockets are designed with a breaking load of greater than 80kN. The forked collar sockets have been independently tested by
ALS Global and a breaking load of ~100kN was recorded. The maximum working load for the forked collar socket will be 20kN.Overhead Bruce Atkinson Full Type Approval Approved 60/12/2016
• Bonomi product number:
15195103 for use on 181mm2,
17.5mm dia. 37/2.5, HdCu
catenary wire.
NA NA Bonomi Italy
• Bonomi part number and conductor diameter to be stamped on the body of the Forked Collar
Socket.
• On the catenary wire body (part number 15199 5107), the distance from the end of the forked
collar socket to the centre of the cuphead pin to be reduced from 30mm to 25mm to allow for
00176 1 UGL/TC Communications JumboSwitch
The JumboSwitch® is a scalable modular design, integrated communications system supporting over 25 different hot swappable, voice and data
interfaces. It integrates data, voice and delay-sensitive serial traffic over Ethernet transport.
JumboSwitch® is a modern, lower cost, alternative to aging voice-centric PDH/SDH backbone communication systems.
JumboSwitch® has a range of chassis sizes, 4U, 2U, 1U, 2S, 1S and DIN rail mounting options and can be implemented in a range of
Signals Russell Shield Full Type Approval Withdrawn 18/09/2018
-4U Card Cage p/n TCRM197
-Main Card for 4U p/n TC3480-
1
-Management Card for 4U p/n
NA NA TC Communications USA, Irvine California 92614
00175 1WE-EF VFL520 12 LED 24W/700mA Solar Powered
Luminaire
This is a narrow-beam pole-mounted luminaire made specifically for the illumination of walkways.
The solar modules achieve 17% efficiency and maintain up to 80% illuminance for the 20 year lifespan of the product. Modules are designed to
withstand wind loads up to 100km per hour.
Structures Joe Cavric Full Type Approval Withdrawn 5/11/2018 VFL520 NA NA WE-EF Lighting
Luminaire – Germany
Solar Unit & Batteries – China
Poles - Australia
00174 1TOA SX2000 Paging Matrix System and
TOA RM200SA Paging Station
MTM is looking to introduce an IP based PA system which allows for greater flexibility in the area of recordings and announcements.
The new PA system will be connected via the Metro Trains Security Network.
A general configuration of the PA system will comprise the below listed products.
1. Soundweb London BLU800 Master DSP (TA-00173)
OCS Peter Dohle Engineering Product Approval Approved 20/01/2017 NA NAUse at Flinders St Station only
00173 1
SoundWeb Londons
-BLU800 Master DSP;
-BLU100;
-BLU-BIB;
MTM is looking to introduce an IP based PA system which allows for greater flexibility in the area of recordings and announcements.
The new PA system will be connected via the Metro Trains Security Network.
A general configuration of the PA system will comprise the below listed products.
1. Soundweb London BLU800 Master DSP (TA-00173)
OCS Peter Dohle Engineering Product Approval Approved 20/01/2017 NA NA Use at Flinders St Station only
00172 1 Siemens Type 8DJH range medium voltage switchgear The Siemens 8DJH switchgear is factory-assembled, type-tested, 3-pole metal-enclosed single-busbar switchgear for indoor installation. Substations Alan Keating Provisional Type Approval Approved 17/11/2016 16/11/2018 8DJH-121509 NA NA Siemens China•24 month trial.
•Assessment of in service performance
Please refer to L1-CHE-PRO-004 for T.A Procedure
Uncontrolled if printed. Controlled by MTM Eng. Systems (OCE)
Page 17 of 22 [email protected]
Metro Trains Melbourne Engineering Approved Product List As of 20/01/2020 (Updated monthly)
TA
NumberIssue Title/Product Function/Application(s)
Applicable
System(s)SME Approval Type Approval Status
Approval/Rejected
DateExpiry
Withdrawal/Suspension
DateType/Model Number
Hardware
Revision No.
Software Version
No.Manufacturer Place of Manufacture Condition and Service Restrictions
00170 1 Vossloh Precast Plinth
The Vossloh Precast Plinth track system is an evolution of the typical in-situ plinth slab track construction method where the precast enables
reduced site works, greater installation accuracy and increased install rates. The precast includes an integrated concrete upstand or ‘kerb’ for
derailment containment.
Track John Dauth Full Type Approval Approved 11/10/2017 VPP-CBG-1 NA NA Vossloh Germany
1. The VCA Plinth shall be installed in accordance with manufacturers installation guidelines.
2. The VCA Plinth shall be compatible with the trackform that has the following characteristics :
o 23 TAL at 115km/h
o 25 TAL at 80km/h
o 115 km/h max. design speed (80 km/h max. operational)
o Max. cant of 40mm
o 50 year design life in accordance with AS3600
o Vossloh 300 Fastening system at 685mm spacing.
3. Interface connections between the underside of the plinths and the deck shall be in accordance
with an approved structural design and warranted as fit for purpose by an MTM approved proof
engineer. The design must accommodate expected variations in deck surface level.
4. To ensure correct operation of Audio frequency circuits, plinths and the concrete interface
connections shall contain no enclosed metallic loops within 500mm of the top of rail.
5. Integrated upstands must be installed on the gauge side of both running rails wherever it is
reasonably practicable to do so. Any gaps or discontinuities between plinth units shall be minimised
and treated to MTM’s approval.
6. Provision of spare components, materials and special tools shall be agreed with MTM
infrastructure.
7. The production, handling, storage and delivery of the plinths shall conform to Quality Control and
Quality Assurance procedures reviewed and accepted by MTM.
8. Design ULS lateral derailment load shall not exceed 138kN when applied to the top of the
upstand.
9. The configuration of the plinth system shall allow for placement of signalling equipment to MTM
standards and Standard plans, with capture of infrastructure requirements for access and egress to
that equipment. And a full and detailed “Rail System Components” report shall be provided to MTM
00170 2 Vossloh Precast Plinth
The Vossloh Precast Plinth track system is an evolution of the typical in-situ plinth slab track construction method where the precast enables
reduced site works, greater installation accuracy and increased install rates. The precast includes an integrated concrete upstand or ‘kerb’ for
derailment containment.
Track Abhi Kirpan Full Type Approval Approved 20/03/2018
VPP-CBG-1 incl. variations:
1. Gauge side upstand
2. Field side upstand
3. No upstand
NA NA Vossloh Germany
1. The VCA Plinth shall be installed in accordance with manufacturers installation guidelines.
2. The VCA Plinth shall be compatible with the trackform that has the following characteristics :
o 23 TAL at 115km/h
o 25 TAL at 80km/h
00170 3 Vossloh Precast Plinth
The Vossloh Precast Plinth track system is an evolution of the typical in-situ plinth slab track construction method where the precast enables
reduced site works, greater installation accuracy and increased install rates. The precast includes an integrated concrete upstand or ‘kerb’ for
derailment containment.
Track Abhi Kirpan Full Type Approval Approved 5/12/2018
VPP-CBG-1 incl. variations:
1. Gauge side upstand
2. Field side upstand
3. No upstand
NA NA Vossloh Germany
1. The VCA Plinth shall be installed in accordance with manufacturers installation guidelines.
2. The VCA Plinth shall be compatible with the trackform that has the following characteristics :
o 23 TAL at 115km/h
o 25 TAL at 80km/h
00169 1 Vossloh W SERIES FASTENING The W21 is the latest version of the Vossloh W system to suit ballasted applications and the W21T is the adaption for turnout bearers. TrackJohn Dauth/Gordon
DjurdjevicFull Type Approval Withdrawn 1/10/2019 1/10/2019 (W21, W21T) NA NA Vossloh Germany
00168 1 Vossloh 300 series slab track fastening system
The Vossloh 300 series fastening which is the world’s most popular on slab track – it offers a range of handling, install and maintenance
benefits since it is mounted directly to the precast without the need for a baseplate giving significant cost reduction.
There is also the possibility of pre-assembly of the components on the precast concrete to aid installation onsite. Since the components are all
retained the components cannot come loose so there is opportunity to increase efficiency and reduce life cycle costs during rail installation and
Track Abhi Kirpan Full Type Approval Approved 23/06/2017 (300-1, 300-UTS) NA NA Vossloh Germany
1.The System 300-1 is approved for use on Direct Fix track. Variants should be considered for
ballasted track subject to demonstration of compliance with MTM sleeper and resilient fastening
requirements.
2. System 300-1 shall be installed in accordance with manufacturers’ installation guidelines.
00167 1 Dahua IP CCTV Camera
An IP Camera with H.264 1080p, PoE, and basic on-board analytics.
ONVIF compliant
Will be used with Dahua branded lenses, but is compatible with C/CS lenses.
OCS Peter Dohle Engineering Product Approval Approved 30/08/2016 DH-IPC-HF8281EP NA NA Dahua China
00167 2 Dahua IP CCTV Camera
An IP Camera with H.264 1080p, PoE, and basic on-board analytics.
ONVIF compliant
Will be used with Dahua branded lenses, but is compatible with C/CS lenses.
OCS Peter Dohle Engineering Product Approval Approved 15/05/2017 DH-IPC-HF8281EP NA NA Dahua ChinaThe existing approved TA00167 camera will be used for reactive/corrective maintenance only and
not to be used in new installations or purchased.
00166 1 Bosch IP CCTV Camera
An IP Camera with H.264 720p, PoE, and basic on-board analytics.
ONVIF compliant
Will be used with Bosch branded lenses, but is compatible with C/CS lenses.
OCS Peter Dohle Engineering Product Approval Approved 30/05/2016 NBN-71013-BA NA NA Bosch Portugal
00165 1 MC-Ballastbond 70
The ballast bonding process (polymer reinforced ballast) is a method of reinforcing ordinary railway ballast. The bonding gives strength and
resilience, and support for the sleepers. Creating a polymer cage in the ballast gives predictable mechanical properties and performance under
load. Achieving the desired mechanical properties of the treated polymer ballast composite is dependent on ballast condition, treated depth,
polymer loading and polymer properties.
Track Gordon Djurdjevic Engineering Product Approval In Progress MC-Ballastbond 70 NA NAMC-Bauchemie Müller
GmbH & Co. KGGermany Registered TA. Back with SME for Type Approval Recommendation - BP - 19/08/2016
00164 1 Medium Voltage Disconnector
Product overview (include description, benefits, limitations).
1 Pole Medium Voltage Disconnector (no load switching), 3.6kVdc, 2.4kAdc, no aux microswitches and with pulling-eye for hook stick operation
Benefits: (Refer attached product brochure and Installation & Maintenance Manual)
- Large isolation air and creepage path
Overhead Ashley Keep Provisional Type Approval Withdrawn 12/07/2019 HAZS Range 2.4kA DC NA NA Mersen Europe Type approval withdrawn as advised by SME, refer to attached email in the folder
00163 1 Treadwell FRP Fence Assembly
The Treadwell fence assembly is made from a fibreglass reinforced plastic (FRP) which is composed of a matrix of plastic augmented by fine
glass fibres usually formed by the process of moulding. The weight and strength of FRP materials are comparable to those of conventional
materials such as aluminium and steel. Upright posts can be positioned up to 2.3m apart. The fence panel stands at 3m tall with spikes cut
along the top section.
Structures John Dauth Full Type Approval Approved 19/05/2017 ArchitEX NA NA Treadwell Australia
Treadwell FRP fences shall:
• Be assembled using only the Treadwell FRP fence components covered by this Type Approval.
The minimum height of the fence shall be 2.5 metres above the adjacent ground level and
constructed in accordance with the requirements of AS 2067 except that razor wire shall be used in
00163 2 Treadwell FRP Fence Assembly
The Treadwell fence assembly is made from a fibreglass reinforced plastic (FRP) which is composed of a matrix of plastic augmented by fine
glass fibres usually formed by the process of moulding. The weight and strength of FRP materials are comparable to those of conventional
materials such as aluminium and steel. Upright posts can be positioned up to 2.3m apart. The fence panel stands at 3m tall with spikes cut
along the top section.
Structures Mark Brookshaw Full Type Approval Approved 2/07/2019 ArchitEX NA NA Treadwell Australia
00162 1 Juniper SRX300 and SRX340
The Juniper SRX300 and SRX340 are upgrades to the existing SRX240 used by MTM and V/Line (the SRX240 is becoming end-of-life).
This firewall is used when additional security is required, or when networks are connected. The SRX300 is a smaller, fanless, design, and has a
similar performance to the existing SRX240. The SRX340 is the same form factor as the SRX240, with upgraded hardware performance and
features. Notably, both models incorporate SFP ports to allow direct fibre connectivity.
ion.
OCS Niels Endres Engineering Product Approval In Progress SRX300 and SRX340 NA NA Juniper China
00161 1 Neousys POC-212 Level crossing Boom Mechanism OCS Niels Endres Engineering Product Approval In Progress POC-212 NA NA Neousys Taiwan
00160 1 Siemens S60 Boom Mechanism & S40 to S60 Conversion Kit Level crossing Boom Mechanism Signals Jim Warwick On Hold Withdrawn N/A N/A 17/08/2017 NA NAType Approval is being rescinded due to a maintenance issue.
Not to be used in any future works.OCS
00159 2 Meanwell Basic 240v to 24vDC power supply. Intended use is to power industrial PCs and network equipment such as 4G routers. Input Range is 100-
240vAC. Temperature Range is -20 -50 ambientOCS Mark Cole Engineering Product Approval In Progress MDR-40-24 NA NA Meanwell China Sent for Review to Mark Cole - 01/07/2016
00158 1 Phoenix Contact Updated on 22/11/2017 to capture 5.5metre masts OCS Mark Cole Engineering Product Approval Approved 13/07/2016 MINI-PS-48 6-DC/24DC/1 NA NA Phoenix Contact China Nil
00157 2 Siemens Tilt Mast
This Type approval has been performed to create an alternative to MTM-FTA-00116(2) RIC Tilt Mast.
The scope of this Type Approval application is limited to the Siemens Easy Access Signal Mast for use on the MTM network for signal mast and
other mast applications.
Signals Glenn Miller Full Type Approval Approved 22/11/2017 N/A
Refer to Appendix 1 in hyperlink.
Note: Existing Siemens Part
Numbers: Masts:
1175104003/1175104004/11751
Refer to Appendix
1 in MTM-FTA-
0157(1) - Type
Approval
NA Siemens Australia
Conditions:-
References contained within these conditions are made to “Siemens Easy Access Mast Full Type
Approval for MTM Evaluation Report” version 1.0 dated 18/07/2016.
00156 1 Siemens Vandal Resistent Trainstop
This is an incremental Provisional Type Approval from the existing JAH to the Siemens Trackguard Trainstop, Style JAV.
The JAH was originally Type Approved by PTC as TAC87/98 and is currently approved by MTM via Grandfather Rights Approval (no available
Certificate).
A trial of the JAV in revenue service will be conducted to demonstrate the vandal resistant features of the JAV. It is proposed to replace the
Signals Russell Shield Provisional Type Approval Approved 15/07/2016 31/12/2016 Part Number:- 390102001 390102001 NA Siemens Australia
1) The Provisional Type Approval is valid for the trial period which shall be concluded and removed
from service by the 31/12/2016.
2) All staff involved in the installation, set to work, test and commission and maintenance activities
during the trial must be fully briefed on the Siemens JAV Trainstop prior to entering the worksite.
00156 2 Siemens Vandal Resistent Trainstop
This is an incremental Provisional Type Approval from the existing JAH to the Siemens Trackguard Trainstop, Style JAV.
The JAH was originally Type Approved by PTC as TAC87/98 and is currently approved by MTM via Grandfather Rights Approval (no available
Certificate).
A trial of the JAV in revenue service will be conducted to demonstrate the vandal resistant features of the JAV. It is proposed to replace the
SignalsColin Waters/Lee
CharnockFull Type Approval In Progress 14/02/2017 30/04/2017 Part Number:- 390102001 390102001 NA Siemens Australia
1) The Provisional Type Approval is valid for the trial period which shall be concluded and removed
from service by the 31/12/2016.
2) All staff involved in the installation, set to work, test and commission and maintenance activities
during the trial must be fully briefed on the Siemens JAV Trainstop prior to entering the worksite.
00155 1 Vossloh 300 SERIES FASTENING
The Vossloh 300 series fastening which is the world’s most popular on slab track – it offers a range of handling, install and maintenance
benefits since it is mounted directly to the precast without the need for a baseplate giving significant cost reduction.
There is also the possibility of pre-assembly of the components on the precast concrete to aid installation onsite. Since the components are all
retained the components cannot come loose so there is opportunity to increase efficiency and reduce life cycle costs during rail installation and
Track Gordon Djurdjevic Full Type Approval Superseded NA NA
00154 1 Vertaic Bollard
Solar powered bollard
500 lumen operation
Vandal resistant
No cabling required
Track &
StructuresNA Full Type Approval Withdrawn N/A N/A 20/06/2016 M10-1SP NA NA Valen Light USA ( AUSTIN TX ) Refer to Correspondence within case number
00153 1 Rail Safety Systems (RSS) Magnetic Safety Barrier
Safety barrier system using steel stanchions which attach magnetically to the web of the live rail. These then hold interlocking fibreglass rails
which provide a physical barrier to prevent people from accidentally entering an area where they could be struck by trains. The benefit of the
system is the speed of installation and removal allowing workers to focus on track work rather than fencing.
Track &
StructuresJoe Cavric Full Type Approval Approved 7/12/2018 NA NA
00152 1 Solar Powered LED lighting.
Leadsun Systems are designed to be ‘All in One’ providing an aesthetically pleasing totally self-contained unit with all control, battery and lighting
maintained at pole height reducing the possibility of damage and vandalism.
A total range of LED lights up to 60W can provide secondary type lighting for applications such as stations, carparks, pathways and facilities. A
combination of Solar Engines and LED Lights with alternative distribution Patterns would be offered depending on layouts. All system designs
Track &
StructuresNA Full Type Approval Withdrawn N/A N/A 20/06/2016 (300-1, 300-UTS) NA NA VOSSLOH GERMANY
00151 1 Extreme ISW 8GbP, 4-SFP, PoE Switch Provide a layer 2 Ethernet network and supply PoE power for CCTV, access control and sensor devices in the MURL. It is also expected that
this switch will be deployed at stations, as part of a standard FLS switch.OCS Niels Endres Engineering Product Approval Approved 27/07/2016
Extreme 16804 (ISW
8GbP,4SFP)NA NA Extreme Taiwan Use on OCS Networks Only
00150 1 AEG “Protect” Uninterruptible Power Supply Range
The AEG UPS is a modular system which combines the AEG Traction Rectifier and AC UPS Protect 8.31 products to provide single-phase input
capability to suit the characteristics of the 2.2kV MTM signal power network.
The system is comprised of a 60kVA industrial UPS with single-phase output augmented by a modular switch mode traction rectifier to take in a
single phase supply. Multiple 60kVA UPS modules can be paralleled to provide higher capacity systems.
Electrical
NetworksBrian Nicholson Provisional Type Approval Approved 27/09/2016 23/10/2017
Traction rectifier 384V/Protect
8.31 60
8.31 60-415-384-
240-H20
Inverter
CE1CW01S.Dy0
Bypass
CE1CE01S.Dy0
AEG Power Solutions GermanyWhere phase dependent signal equipment is present this equipment shall only be placed into
service when installed with independent check sync protection relay and with external
synchronisation available. The unit shall always be installed with the AEG proprietary LBS included.
00150 2 AEG “Protect” Uninterruptible Power Supply Range
The AEG UPS is a modular system which combines the AEG Traction Rectifier and AC UPS Protect 8.31 products to provide single-phase input
capability to suit the characteristics of the 2.2kV MTM signal power network.
The system is comprised of a 60kVA industrial UPS with single-phase output augmented by a modular switch mode traction rectifier to take in a
single phase supply. Multiple 60kVA UPS modules can be paralleled to provide higher capacity systems.
Electrical
NetworksBrian Nicholson Provisional Type Approval Approved 27/06/2016 27/06/2017
Traction rectifier 384V/Protect
8.31 60
8.31 60-415-384-
240-H20
Inverter
CE1CW34P.Dy2
Bypass
CE1CE50H.DY4
AEG Power Solutions Germany
Where phase dependent signal equipment is present this equipment can only be placed into service
when installed with independent check sync protection relay and with external synchronisation
available. The unit must always be installed with the AEG proprietary LBS included. This will likely
impact on the firmware and software versions provided by AEG.
00150 3 AEG “Protect” Uninterruptible Power Supply Range
The AEG UPS is a modular system which combines the AEG Traction Rectifier and AC UPS Protect 8.31 products to provide single-phase input
capability to suit the characteristics of the 2.2kV MTM signal power network.
The system is comprised of a 60kVA industrial UPS with single-phase output augmented by a modular switch mode traction rectifier to take in a
single phase supply. Multiple 60kVA UPS modules can be paralleled to provide higher capacity systems.
Electrical
NetworksBrian Nicholson Provisional Type Approval Approved 20/09/2017 23/12/2017
Traction rectifier 384V/Protect
8.31 60
8.31 60-415-384-
240-H20
Inverter
CE1CW34P.Dy2
Bypass
CE1CE50H.DY4
AEG Power Solutions Germany
Where phase dependent signal equipment is present this equipment can only be placed into service
when installed with independent check sync protection relay and with external synchronisation
available. The unit must always be installed with the AEG proprietary LBS included. This will likely
impact on the firmware and software versions provided by AEG.
00150 4 AEG “Protect” Uninterruptible Power Supply Range
The AEG UPS is a modular system which combines the AEG Traction Rectifier and AC UPS Protect 8.31 products to provide single-phase input
capability to suit the characteristics of the 2.2kV MTM signal power network.
The system is comprised of a 60kVA industrial UPS with single-phase output augmented by a modular switch mode traction rectifier to take in a
single phase supply. Multiple 60kVA UPS modules can be paralleled to provide higher capacity systems.
Electrical
NetworksBrian Nicholson Provisional Type Approval Approved 20/12/2017 30/05/2018
Traction rectifier 384V/Protect
8.31 60
8.31 60-415-384-
240-H20
Inverter
CE1CW34P.Dy2
Bypass
CE1CE50H.DY4
AEG Power Solutions Germany
Where phase dependent signal equipment is present this equipment can only be placed into service
when installed with independent check sync protection relay and with external synchronisation
available. The unit must always be installed with the AEG proprietary LBS included. This will likely
impact on the firmware and software versions provided by AEG.
00150 5 AEG “Protect” Uninterruptible Power Supply Range
The AEG UPS is a modular system which combines the AEG Traction Rectifier and AC UPS Protect 8.31 products to provide single-phase input
capability to suit the characteristics of the 2.2kV MTM signal power network.
The system is comprised of a 60kVA industrial UPS with single-phase output augmented by a modular switch mode traction rectifier to take in a
single phase supply. Multiple 60kVA UPS modules can be paralleled to provide higher capacity systems.
Electrical
NetworksAlan Keating Full Type Approval Approved 19/02/2018 N/A
Traction rectifier 384V/Protect
8.31 60NA NA AEG Power Solutions Germany
This equipment is not to be placed into service or utilised in conjunction with any equipment during
train operational hours. It will be isolated, electrically, during testing from equipment which is in
service during train operation times, and not connected in any circumstances where phase
synchronisation would be required such as in parallel with other incoming supplies. This equipment
00149 1 Siemens Simatic IPC
The product is proposed for, but not limited to the NMCR project, which will be used as protocol converter and/or Technicians Maintenance
Terminal i.e. MoviolaW
The product is a PC, which hardware is designed for industrial environment, SRA proposed to be implemented as Control System equipment as
a non-vital equipment.
Signals Peter Dohle Full Type Approval Approved 20/06/2016 IPC 427D NA NA Siemens Germany
Intended Application 1: Protocol Converter (CSPC) : This device is only approved for operation in
equipment rooms in order to comply with the environmental requirements: The device must be
installed with clearance of at least 100mm from the interfaces and at least 50mm from the non-
interface sides. The device must be equipped with a CFast card, HDD or SDD. The storage media
00148 1 Friction Buffer Stop The buffer stop is designed to bring trains to a complete halt in the available track.Track &
StructuresTimothy Powell Full Type Approval Approved 29/07/2016 N/A NA NA Klose GmbH Germany
1. The friction buffer stops shall be designed in accordance with MTM End of Track Protection
standard (MTST 0000002-08 L1-CHE-STD-032).
2. Friction buffer stops are to be installed in accordance with Martinus Installation & Maintenance
Manual.
00147 1 ADS Pipe• Gravity and Low-Head water conveyance.
• Groundwater/water table removal.
Track &
StructuresTimothy Powell Engineering Product Approval Approved 3/05/2016 HDPE (various) NA NA ADS Various
•Installation of pipe shall be in accordance with ADS N12 Dual-Wall Corrugated HDPE Pipe
Installation Guide, AS/NZS 2566.2 and
project specifications.
• The design of ADS N12 Dual-Wall Corrugated shall comply with AS/NZS 2566.1. HDPE Pipe
00145 1 Frauscher Axle Counter Track Vacany Detection Signals Nick Thompson Full Type Approval Superseded FAdC-R2 NAMTM - FAdC-R2 R2
approval Version 6
Frauscher Sensor
Technology
00145 2 Frauscher Axle Counter Track Vacany Detection Signals Nick Thompson Full Type Approval Superseded FAdC-R2 NAMTM - FAdC-R2 R2
approval Version 6
Frauscher Sensor
Technology
1. Limited to the level Crossing stage 2 scope (Werribee & Craigieburn lines).
2. The conditional interim TA approval until 10,000 operations have been recorded (currently
3,900) without failure.
3. The WNC protocol and CBI interface is fully proven at Laverton.
Please refer to L1-CHE-PRO-004 for T.A Procedure
Uncontrolled if printed. Controlled by MTM Eng. Systems (OCE)
Page 18 of 22 [email protected]
Metro Trains Melbourne Engineering Approved Product List As of 20/01/2020 (Updated monthly)
TA
NumberIssue Title/Product Function/Application(s)
Applicable
System(s)SME Approval Type Approval Status
Approval/Rejected
DateExpiry
Withdrawal/Suspension
DateType/Model Number
Hardware
Revision No.
Software Version
No.Manufacturer Place of Manufacture Condition and Service Restrictions
00145 3 Frauscher Axle Counter Track Vacany Detection Signals Nick Thompson Full Type Approval Superseded FAdC-R2 NAMTM - FAdC-R2 R2
approval Version 6
Frauscher Sensor
Technology
1. Limited to the level Crossing stage 2 scope (Werribee & Craigieburn lines).
2. The conditional interim TA approval until 10,000 operations have been recorded (currently
3,900) without failure.
3. The WNC protocol and CBI interface is fully proven at Laverton.
00145 4 Frauscher Axle Counter Track Vacany Detection Signals Nick Thompson Full Type Approval Approved 8/08/2017 FAdC-R2 NAMTM - FAdC-R2 R2
approval Version 6
Frauscher Sensor
Technology
1. MTM standards shall be complied with for Design and Installation of the axle counting system.
2. That when integrated into a Westrace MkII via a WNC network, the Moviola Diagnostic System
shall be configured to monitor the Axle Counter System as well as the Frauscher FDS system and
that the interface communication parameters are fully documented and approved.
00144 1 CPY250 LED 3500K Canopy/Soffit Luminaire
The CPY250™ LED Canopy/Soffit Luminaire has an extremely thin profile constructed of rugged cast aluminum. It can be surface mounted
easily from below the canopy deck and also has the ability to be pendant mounted or hook & cord mounted. Direct imaging of the LEDs is
eliminated with a highly efficient patterned flat or 0.91" (23mm) drop glass lens.
Applications: Petroleum canopies, CNG fueling stations, low-medium bay general lighting, soffits
Track &
StructuresJoe Cavric Engineering Product Approval Withdrawn NA XCC Vers A NA NA Cree USA
00143 1 Composite Station Platform
The Composite Station Platform is manufactured from fibre reinforced polymer (FRP) where glass fibres (aramid) are encased in a particular
resin under high temperature.
The product is intended to compete with traditional methods of producing platforms (typical constructed insitu from steel, concrete and asphalt).
Track &
StructuresNA Provisional Type Approval Rejected N/A N/A N/A NA NA Exel Composites Australia
00142 1 Ballast CageA Ballast Cage is a steel cage mounted to the top of a grated drainage pit to prevent ballast from covering/entering the pit and reducing its inlet
capacity.
Track &
StructuresTimothy Powell Engineering Product Approval Approved 12/05/2016 N/A NA NA Manufactured Australia
• Top of ballast cage to be installed 100mm above top of sleeper height
• Site inspection prior to undertaking maintenance activities to identify and mark risks within the rail
corridor (i.e. train stops, signal cables, existing pits, etc…)
• Lid designed to be trafficable by construction / maintenance vehicles
00141 1 4G RouterThe Cybertec Model 2455 is a 4G router, and is able to provide secure remote connectivity via a VPN (virtual private network), supporting a
number of encryption and connection options.OCS Niels Endres Engineering Product Approval Approved 8/04/2016 2455 NA NA Cybertec Australia Use on OCS Networks Only
00140 1 Industrial Etherenet ExtenderThese devices are designed to extend Ethernet networks over traditional twisted-copper pair cabling, over long distances (up to 15km, based on
the quality of the copper cabling being used).OCS Niels Endres Engineering Product Approval Approved 8/04/2016 DDW-142 NA NA Westermo Sweden Use on OCS Networks Only
00139 1 Moxa PoE SwitchThe EDS-G512E-8PoE-4GSFP-T is part of the Moxa range of Industrial PoE switches. These devices are designed to provide gigabit switching
and supply PoE power to remote devices over copper CAT5/CAT6 cabling.OCS Niels Endres Engineering Product Approval Approved 8/04/2016 EDS-G512E-8PoE-4GSFP-T NA NA Moxa Taiwan Use on OCS Networks Only
00138 1 Plastream Steel Reinforced HDPE Pipe Steel reinforced HDPE pipe (SRP), either solid or slotted.Track &
StructuresHassan Elaina Engineering Product Approval Approved 16/06/2016
Composite Drainage Pipe
Slotted Drainage PipeNA NA Rocla Australia
Installation of pipe shall be in accordance with Plastream Steel Reinforced HDPE Pipe Installation
Guide, AS/NZS 2566.2 and project specifications. The design and installation of Plastream pipes
shall be completed by a qualified and competent engineer to demonstrate compliance to AS/NZS
2566.1. Loading calculations shall be provided for each project.
00137 1Metrospec 38” Slimline Double Sided Passenger Information
Display
The Metrospec 38” Slimline PID is an LCD panel allowing greater functionality and information for customers.
The LCD panels are IP65 rated and are driven by a PC situated within the Panel. OCS Judy Bashta Engineering Product Approval Approved 8/04/2016 MS4238-1500
Graphics
Firmware
20150914-
SL4238V11
NA Metrospec Australia Use on OCS Networks Only
00136 1 Edilon sedra Jointelast STP-25edilon)(sedra Jointelast STP-25 is a two-component polymer material for rail joint sealing for train- and tram track (paved-in) structures. It would
be used as a temporary repair for track defects identified at level crossings where the crossing surface is asphalt.
Track &
StructuresNA Full Type Approval In Progress edilon)(sedra Jointelast STP-25 NA NA edilon)(sedra Haarlem, Netherlands
00135 1 Arthur Flury Low Speed Section Insulator Low speed areas only such as sidings, stabling yards, depots. Overhead Ashley Keep Provisional Type Approval Approved 14/07/2016 14/07/2017Type FOK3 Low Speed Section
Insulator - 655.300.046N/A N/A Arthur Flury Switzerland
Installation at Cragieburn Train Maintenance Facility as part of a 6 month trial. The design
incorporating the proposed LSSI take into account its operating parameters such as maximum line
speed, tension etc which are available on drawing L9563
00134 1 RailEX FRP Handrail Non-conductive type handrail for use in areas requiring electrical isolation and to alleviate touch potential.Track &
StructuresJohn Dauth Full Type Approval In Progress RailEX Round Tubular Handrail NA NA Treadwell Group Australia
00133 1 Martinus rail Expansion/Adjustment Switch Track component designed to absorb the thermal stresses induced in the rail during extreme weather conditions and track loading preventing
track misalignments
Track &
StructuresGordon Djurdjevic Full Type Approval In Progress Type 1 NA NA Martinus rail
00132 1 FIN-LUBE Point switch plate lubricant Signals Russell Shield Engineering Product Approval Approved 22/12/2015FIN-LUBE TF/EP and metal
cleaner NA NA INTERFLON Netherlands
Product to be used and stored in line with health and safety instructions outlined in the Material
Safety Data Sheet (MSDS) and manufacturer specifications.
00131 1Industrial 10/100/1000 BaseT(X) to 100/1000 BaseSFP
media converter
General use across the OCS Security Network.
Specific application will vary across each EC/design that utilises this device.OCS Peter Dohle Full Type Approval In Progress IMC-21GA-T NA NA Moxa N/A
00130 1PoE industrial 10/100 BaseT(X) to 100BaseFX media
converter
General use across the OCS Security Network.
Specific application will vary across each EC/design that utilises this device.OCS Peter Dohle Full Type Approval In Progress IMC-P101-M-SC-T NA NA Moxa N/A
00129 1 CPY250 LED Canopy/Soffit Luminaire ED White Light Fittings to replace the existing High Pressure Sodium (Yellow Light) FittingsTrack &
StructuresJoe Cavric Engineering Product Approval Approved 16/12/2015 XCC Vers A NA NA Cree USA
00128 1 Platform Gap Filler Mounted to coping to assist with passenger boarding trainsTrack &
StructuresHassan Elaina Full Type Approval Approved 22/12/2015 48mm & 66mm NA NA Delkor Australia
1. The 48mm PGF shall be installed as an interim measure as a substitute for the preferred 65mm
PGF. The 48mm PGF (with 15mm packing plate) may be approved to remain in place at the
installed location, subject to a satisfactory trial period and proven performance in the field. A report
on performance will need to be provided to justify this before a Full Type Approval is granted.
00127 1Industrial 10/100/1000 BaseT(X) to 100/1000 BaseSFP
media converterConverts between a single 10/100/1000BaseT(X) copper RJ45 and 100/1000BaseSFP fibre interface OCS Peter Dohle Full Type Approval Registered IMC-21GA-T NA NA Moxa
00126 1PoE industrial 10/100 BaseT(X) to 100BaseFX media
converterConverts between a single 10/100BaseT(X) copper RJ45 and 100BaseFX fibre SC OCS Peter Dohle Full Type Approval Registered IMC-P101-M-SC-T NA NA Moxa
00125 1AusTrak Full Depth Broad Gauge Concrete Guard Rail
SleepersConcrete Sleeper compatible with guardrail installation
Track &
StructuresGordon Djurdjevic Full Type Approval Approved 22/12/2015 212-22B-e-GRA NA NA Austrak Australia
The Guardrail Sleepers shall be installed in a face. No interspersion with other sleeper type shall be
permitted unless approved by the Chief Engineer.
Guardrail Sleepers GR2 – GR8 shall be installed at 600mm centres as per manufacturer’s design.
GR1 Sleepers shall be installed at 685mm centres.
00125 2AusTrak Full Depth Broad Gauge Concrete Guard Rail
Sleepers (Trainstops)Concrete Sleeper compatible with guardrail installation
Track &
StructuresGordon Djurdjevic Full Type Approval Approved 22/12/2015 NA NA Austrak Australia
00124 1 TechDRAIN T5 GeonetDrainage blanket to be installed beneath the structural fill layer of the track formation to capture and direct groundwater flow to the groundwater
drainage system on each side of the rail cutting at Blackburn, preventing it from entering the rail formation.
Track &
StructuresHassan Elaina Engineering Product Approval Approved 9/12/2015 TechDRAIN T5 GTG 512 NA NA Intermas Geosynthetics Spain
• This request for product approval shall ONLY apply for use of TechDRAIN on the Blackburn Rd
grade separation project. Any request for further use at other locations, on the MTM network, shall
be reassessed and a separate product approval application must be submitted.
• The product must be installed strictly in accordance with the manufacturer’s installation guidelines
00123 1 iDS Cable Troughing Installation of signalling and comms routes without the need for excessive excavation.Track &
StructuresGraeme Miles Full Type Approval Approved 14/01/2016 iDS FRD1, FRD2 & FRDP NA NA integrated Ducting Systems UK Refer to TA Certificate
00122 1 Tesacrete Elastometic Concrete TBCTrack &
StructuresTBC Full Type Approval Registered NA NA
00121 2 Hilti X-BT system Track Circuit Connections (M6, M8 and M10 stainless steel lug for electrical connections) Signals Jim Warwick Full Type Approval Approved 15/08/2017 X-BT NA NA Hilti Lichtenstein
References contained within these conditions are made to "Hilti X-BT Threaded Fastener, Type
Approval Submission"
1) "The User" is the Project or Infrastructure Delivery Manager responsible for the application
design and installation or maintenance of the Hilti X-BT Threaded Fastener system.
00120 1 SpikeFast
Remediation of holes in timber sleepers and the remediation of seat abrasion on timber sleepers.
Repair damage to timber sleepers.
Repairing timber sleepers for re-gauging.
Track &
StructuresGordon Djurdjevic Provisional Type Approval Approved 13/04/2016 30/10/2016 ES-50 RM/RMII & ET-75 NA NA Willamette Valley Company USA
The Product shall be stored in ideal conditions and applied strictly in accordance with the
manufacturers instructions, dispensing guidelines and curing rates/ The product shall not be used
past its 'used by date,' as performance cannot be guaranteed. The product can cause eye, skin and
respiratory burns. Use of PPE and safe handling instructions as outlined in the MSDS must be
00120 2 SpikeFast
Remediation of holes in timber sleepers and the remediation of seat abrasion on timber sleepers.
Repair damage to timber sleepers.
Repairing timber sleepers for re-gauging.
Track &
Structures
Gordon
Djurdjevic/Hassan
Elaina
Full Type Approval Approved 21/10/2019 ES-50 RM/RMII & ET-75 NA NA Willamette Valley Company USA
The Product shall be stored in ideal conditions and applied strictly in accordance with the
manufacturers instructions, dispensing guidelines and curing rates/ The product shall not be used
past its 'used by date,' as performance cannot be guaranteed. The product can cause eye, skin and
respiratory burns. Use of PPE and safe handling instructions as outlined in the MSDS must be
00119 1 Siemens TD84M Mk3 Trailable Dual Control Point Machine Point Machine Signals Russell Shield Full Type Approval Superseded 25/09/2015 31/12/2015 Refer to TA Certificate NA NA Siemens Germany
00119 2 Siemens TD84M Mk3 Trailable Dual Control Point Machine Point Machine Signals Russell Shield Full Type Approval Approved 18/12/2015 Refer to TA Certificate NA NA Siemens Germany
1) This Type Approval is for the Siemens TD84M Mk3 point machine, piece number 1335101601.
Any subsequent models shall be reassessed for further Type Approval prior to use in the MTM rail
network.
2) Installers, maintainers and operators shall be cognisant of the safety warnings and pinch points
00118 1 Ambient Noise Sensing MicrophoneThe Digital Ambient Noise Controller and Ambient Noise Sensing Microphone will be components of the OCS / Passenger Information System /
Public Address System.OCS Mark Cole Engineering Product Approval Approved 22/12/2015 AN-9001 NA NA TOA Corporation N/A
Forms part of the OCS Public Address System, to improve customer audio clarity while minimising
unnecessary loudness for nearby residences, and is to be used with exclusively with the DP-L2
Digital Ambient Noise Controller (TA 00117).
00117 1 Digital Ambient Noise ControllerThe Digital Ambient Noise Controller and Ambient Noise Sensing Microphone will be components of the OCS / Passenger Information System /
Public Address System.OCS Mark Cole Engineering Product Approval Approved 22/12/2015 DP-L2 NA NA TOA Corporation N/A
Forms part of the OCS Public Address System, to improve customer audio clarity while minimising
unnecessary loudness for nearby residences, and is to be used with exclusively with the AN-9001
Ambient Noise Sensing Microphone (TA 00118).
00116 1 Dwarf Tilting Signal Mast (2.5 Meters) Dwarf Signal Mast Structure (Built In Tilting Functionality) Signals Russell Shield Full Type Approval Superseded 28/10/2015 31/12/2015 TILTMAST2500 NA NA
Rail Industry Construction
Pty Ltd
Mayfield West, NSW 2304
Australia
00116 2 Dwarf Tilting Signal Mast (2.5 Meters) Dwarf Signal Mast Structure (Built In Tilting Functionality) Signals Russell Shield Full Type Approval Approved 20/11/2015 TILTMAST2500 NA NA
Rail Industry Construction
Pty Ltd
Mayfield West, NSW 2304
Australia
1. Only to be installed with front mounted "U" style LED signal heads with a maximum weight of
50kg (including brackets).
2. When working with the tilting mast, hard hat shall always be worn.
3. The installation of the tilting mast shall not foul the running lines.
00115 1 STRAIL Rubber Level Crossing System Level Crossing ConstructionTrack &
StructuresGordon Djurdjevic Provisional Type Approval Approved 26/08/2015 30/06/2016
STRAIL Rubber Level Crossing
SystemNA NA
Gummiwerk KRAIBURG
Elastik GmbHGermany
1. Approved for one trial location only.
2. Configuration to explicitly recorded in the Full Type Approval.
3. Shall be installed to manufacturer’s instructions.
4. Road speed limit shall not exceed 110 km/hr.
00115 2 STRAIL Rubber Level Crossing System Level Crossing ConstructionTrack &
StructuresGordon Djurdjevic Full Type Approval Approved 10/12/2018 -
STRAIL Rubber Level Crossing
SystemNA NA
Gummiwerk KRAIBURG
Elastik GmbHGermany
1. Shall be installed to manufaturer's instruction
2. Road speed limit shall not exceed 110km/h
3. Sleeper spacing in Level Crossing shall be nominal 600mm
00114 1 Holdfast / Rosehill Rubber Level Crossing System Level Crossing ConstructionTrack &
StructuresTimothy Powell Provisional Type Approval Approved 26/08/2015 30/06/2016
Holdfast / Rosehill Rubber Rail
Crossing PanelsNA NA
Rosehill Polymers Limited
UKUK
1. Approved for one trial location only.
2. Configuration to explicitly recorded in the Full Type Approval.
3. Sleepers spacing through level crossing shall be at 600mm as rubber panels are 1.8m in length.
This ensures adequate support where panels are joined.
00114 2 Holdfast / Rosehill Rubber Level Crossing System Level Crossing ConstructionTrack &
StructuresTimothy Powell Full Type Approval Approved 15/02/2018
Holdfast / Rosehill Rubber Rail
Crossing PanelsNA NA Rosehill Polymers Limited UK UK
1. Panels shall be installed as per the manufacturer’s instructions and any relevant site specific
design drawings.
2. Track shall be within construction tolerances, free of defects including fouled ballast, and in
accordance with standard drawing STD_R0022 for the length of the level crossing or road-rail
00113 1 RUGGEDCOM RS900G Network switch OCS Peter Dohle Full Type Approval Superseded 7/09/2015 RS900G RS900G Firmware: ROS4.2.1 Siemens Canada To be used on OCS Networks only
00113 2 RUGGEDCOM RS900G Network switch OCS Peter Dohle Full Type Approval Superseded 2/11/2015 RS900G RS900G Siemens Canada To be used on OCS Networks only
Please refer to L1-CHE-PRO-004 for T.A Procedure
Uncontrolled if printed. Controlled by MTM Eng. Systems (OCE)
Page 19 of 22 [email protected]
Metro Trains Melbourne Engineering Approved Product List As of 20/01/2020 (Updated monthly)
TA
NumberIssue Title/Product Function/Application(s)
Applicable
System(s)SME Approval Type Approval Status
Approval/Rejected
DateExpiry
Withdrawal/Suspension
DateType/Model Number
Hardware
Revision No.
Software Version
No.Manufacturer Place of Manufacture Condition and Service Restrictions
00113 3 RUGGEDCOM RS900G Network switch OCS Peter Dohle Full Type Approval Approved 6/06/2016 RS900G RS900G Siemens Canada OCS Industrial Control & Signalling Networks
00112 1 200mm Glass Disc Insulator For installation on the overhead wiring system Overhead Izy Perona Full Type Approval Approved 2/12/2015 CE-U70CN N/A N/ANanjing Electric (Group) Co.
Ltd.China Nil
00111 1 66KV Insulators 22kV Feeders Overhead Ashley Keep Full Type Approval In ProgressAs detailed on STD_E0138,
STD_E0139 and STD_E0140N/A N/A
Tyco Electronics
Australian Powerline
Industries
00110 1Single core, rubber flexible tinned copper cable EPR/CPE
3.3kVSecondary Insulation Bonding Cable Overhead Ashley Keep Full Type Approval In Progress MEKAHV070BK N/A N/A Aflex cables
00109 1 JR12 DCCB Safety Barrier Installation in front of JR12 DCCBs for protection against inadvertent contact by trained substation personnelTrack &
StructuresGeorge Marulli Full Type Approval Approved 12/06/2015 As per drawing STD_E0148 N/A N/A Metro Trains Melbourne Australia
• The materials listed as safety critical in the ‘Material part Numbers’ document affect the safety
criticality rating of the barrier and shall not be substituted with any other brands or models.
• Drawing STD_E0148 is only suitable for JR12 DCCB equipped Substations/Tiestations with zones
equal to or less than 2750mm in width. Substations/Tiestations with zones greater than 2750mm
00108 1 Benkler MK1HT 4 Hole Kit Plastic Coated Fishplate (PFC) 4 Hole Mechanical Insulated Joint KitTrack &
StructuresTimothy Powell Full Type Approval Superseded 21/04/2017
BK-47KGMK1HTX4H
BK-50KGMK1HTX4H
BK-53KGMK1HTX4H
BK-60KGMK1HTX4H
N/A N/A Tenconi SA
00108 1 Benkler MK1HT 4 Hole Kit Plastic Coated Fishplate (PFC) 4 Hole Mechanical Insulated Joint KitTrack &
StructuresTimothy Powell Full Type Approval Approved 9/02/2018 N/A
BK-47KGMK1HTX4H
BK-50KGMK1HTX4H
BK-53KGMK1HTX4H
BK-60KGMK1HTX4H
N/A N/A Tenconi SA
1. 4 hole Benkler joint shall only be installed in and around points and crossings to replace an
existing 4 hole mechanical joint where a six hole Benkler joint cannot be fitted due to space
restriction. Size, location and condition of the boltholes must be checked prior to installation. Note:
Drilling pattern is compatible.
00107 1 Thermoplastic Urethane Escalator Handrail. Escalator hand rail.Track &
StructuresJohn Dauth Full Type Approval Approved 12/06/2015 12/06/2016 NT3000 N/A N/A EHC Global China
• Approved for 6 month trial at Box Hill to monitor
• Installation in accordance with EHC – NT Handrail Replacement – On site Installation to an
Existing Machine
• Following products should NOT be used for cleaning
00106 1 Next Generation CBI- SmartLock 400 Computer Based Interlocking system. Signals Glenn Miller Full Type Approval Approved 3/07/2015Next Generation CBI- SmartLock
4001.4.4 1.4.4
Alstom Transport/Alstom
Signalling SolutionsFrance Nil
00105 1 Millennium Call Processing System MURL Station Public Address System OCS Mark Cole Engineering Product Approval Approved 15/12/2015 METRO-MCPS-V1 NA NA Dallas Delta Pty Ltd
This approval is to be limited to this specific functionality to allow remote public address
announcements to the MURL stations only.
Changes to existing public address system operation at all other locations may consider this system
for suitability / flexibility and if suitable could be approved by amendment to this TA.
00104 1 EZSeries 10”TFT Windows HMIHMI Panels are to be used within MTM substations, tie stations and switching stations as part of the current SCADA system to allow operators
remote control and monitoring of equipment within the facility
Electrical
NetworksMark Cole Full Type Approval Approved 10/02/2016 31/12/2016
EZSeries 10” & 15”TFT Windows
HMI
• EZ Series Touch Panel Editor
(P/N EZ-ANELEDIT)
• EZ Series Touch
Panel Editor (P/N
EZ-ANELEDIT)
• CPU Type: Intel
NA UTICOR USA
1. Only authorised HV Operators with level T1 and T2 certification are to operate the panel.
2. Two locations will trial the HMI Panels for a period of 6 months prior to network wide rollout. The
trials will be conducted at Burnley Substation and Surrey Hills Tie Station. If trials are deemed
successful, network wide rollout will occur.
00103 1Fibre Coarse Wave Division Multiplexer (CWDM) Modules
and SFP TransceiversFor general use across the OCS Security Network. Typically used to channel local site comms to external site bearers OCS Mark Cole Full Type Approval In Progress Infinimux CWDM MUX Modules Various NA PlusOptics Under Review of OCE Eng Mgr
00102 1 Adjustment switch Track component designed to absorb the thermal stresses induced in the rail during extreme weather conditions and track loading preventing
track misalignments
Track &
StructuresTBC Full Type Approval In Progress Type 1 NA NA Martinus rail Under Review of Track Engineering Manager
00101 1 Network Layer 3 Switch and Modules
For general use across the OCS Security Network to allow Ethernet copper or and/or fibre connectivity up to 10Gbps. The Summit-X460-G2 is
a Layer 3 (WAN access) switch typically used to channel local site comms to external site bearers.
Performance and connectivity options vary, based on the selection of modules. Refer Attachment 1 – Datasheet Summit-X460-G2_Series.
OCS Mark Cole Full Type Approval In ProgressSummit-X460-G2 Switch and
ModulesNA NA Extreme Networks Under Review of OCE Eng Mgr
00100 1 Network Layer 2 Switch and Modules
For general use across the OCS Security Network to allow Ethernet copper or and/or fibre connectivity up to 1Gbps. The Summit-X430-G2 is a
Layer 2 (LAN access) switch typically used to provide comms access to devices such as cameras, Remote Terminal Units, PCs... .
Performance and connectivity options vary, based on the selection of SFPs (transceivers). Refer Attachment 1 – Datasheet Summit-
X430_Series.pdf.
OCS Mark Cole Full Type Approval In ProgressSummit-X430-24P Switch and
ModulesNA NA Extreme Networks Under Review of OCE Eng Mgr
00099 1 Ethernet Remote Terminal Unit Controller
For general used across the OCS Security Network to take status information from various ‘on/off’ inputs (such as alarm contact status), and
translate those inputs to other local ‘on/off’ outputs (such as CCTV Camera alarm detection input detection) and/or translate the inputs to IP
SNMP messaging for transfer by the Security Network to control software (such as, but not limited to, CCTV System control software DVTel
Latitude).
OCS Mark Cole Full Type Approval In Progress ioLogik E2210-T NA NA Moxa Under Review of OCE Eng Mgr
00098 1 Ethernet Extender
For general use across the OCS Security Network to allow Ethernet connectivity across low standard cabling (ie Cat 3 instead of Cat 5/6), or
standard Ethernet cabling that exceeds the standard of 100m. This is achievable by transmitting by Very-high-bit-rate Digital Subscriber Line
(VDSL) that sacrifices nominal Ethernet equipment data throughput.
The ED3146-22B I/Os support:
OCS Mark Cole Full Type Approval In Progress ED3146-22B NA NA EtherWAN Under Review of OCE Eng Mgr
00097 1 Power redundancy Automatic Transfer Switch (ATS)
For general use across the OCS Security Network allowing devices with single power feed connections, to be feed with dual power.
The function of the ATS is to feed power from the primary source in normal mode, but seamlessly switch to the secondary source in the
absence of primary power.
The AP7723 electronics is dual redundant (no single point of failure), and also provides SNMP remote statusing.
OCS Mark Cole Full Type Approval In Progress AP7723 NA NAAmerican Power Conversion
(APC)Under Review of OCE Eng Mgr
00096 1 Claretech Supreme Rail Lubricant Lubricating GreaseTrack &
StructuresGordon Djurdjevic Full Type Approval Approved 13/07/2017 0027/030003 NA NA R S Clare & Co Ltd UK
1. The product is harmful if swallowed, can cause burns and may cause sensitisation by inhalation
and skin contact. Use of PPE and safe handling instructions as outlined in the Material Safety Data
Sheets must be strictly adhered to.
2. Mandatory training of staff in the safe and correct use and handling of the product must be
00095 1 Lincoln Wayside Rail Lubricator System Rail Lubrication SystemTrack &
StructuresGordon Djurdjevic Full Type Approval Superseded 7/08/2015 30/06/2015
Wayside Railroad Lubricator:
85666 & 85667
Clamp Kit: 276624 & 276625
Wiper Bar: 272946
NA NA Lincoln Industrial Corp
1. The lubricator shall be installed in accordance with manufacturer’s installation manual and MTM
Rail Lubrication Standard.
2. The lubricator shall be installed with an amplifier gain adjustment box, electronic signal
conditioning module (for filtering), suppressors and wiring configured to turn off hydraulic track
00095 1 Lincoln Wayside Rail Lubricator System Rail Lubrication SystemTrack &
StructuresGordon Djurdjevic Full Type Approval Superseded 7/07/2017 N/A
Wayside Railroad Lubricator:
85666 & 85667
Clamp Kit: 276624 & 276625
NA NA Lincoln Industrial Corp
1. The lubricator shall be installed in accordance with manufacturer’s installation manual and MTM
Rail Lubrication Standard.
2. The lubricator shall be installed with an amplifier gain adjustment box, electronic signal
conditioning module (for filtering), suppressors and wiring configured to turn off hydraulic track
00095 2 Lincoln Wayside Rail Lubricator System Rail Lubrication SystemTrack &
StructuresGordon Djurdjevic Full Type Approval Superseded 22/12/2017
Wayside Railroad Lubricator:
85666 & 85667
Clamp Kit: 276624 & 276625
NA NA Lincoln Industrial Corp
1. The lubricator shall be installed in accordance with manufacturer’s installation manual and MTM
Rail Lubrication Standard.
2. The lubricator shall be installed with an amplifier gain adjustment box, electronic signal
conditioning module (for filtering), suppressors and wiring configured to turn off hydraulic track
00095 3 Lincoln Wayside Rail Lubricator System Rail Lubrication SystemTrack &
StructuresGordon Djurdjevic Full Type Approval Approved 22/02/2019
Wiper Bar Kit - 272946, 276624,
276625. Rail Sensor Kit -
86001,86002. Smart Rail Lube
Contoller - 03-WS-002000 JSG
NA NA Lincoln Industrial Corp
1. The lubricator shall be installed in accordance with manufacturer’s installation manual and MTM
Rail Lubrication Standard.
2. The lubricator shall be installed with an amplifier gain adjustment box, electronic signal
conditioning module (for filtering), suppressors and wiring configured to turn off hydraulic track
00094 1 Contec ClipFix System Cable channel installation to the foot of rail.Track &
StructuresGordon Djurdjevic Full Type Approval Approved 16/10/2015 Refer to TA Certificate NA NA
Contec Transportation
SystemsGermany Refer to TA Certificate
00093 1 Modular Raised Boarding Platform Composite Raised platform at designated boarding point.Track &
StructuresGordon Djurdjevic Full Type Approval Withdrawn 24/09/2019 Drawing RBP001 NA NA Excel Composites Australia
A Trial in MURL has addressed an immediate safety issue raised by drivers until a permanent
solution is progrssed.
00092 1Vossloh Contained Rodding (VCD) System for Tangential
Turnouts Model No: VCD-01Track Turnout
Track &
StructuresGordon Djurdjevic Full Type Approval In Progress VCD-01 NA NA Vossloh Cogifer Australia
00091 1 Crown Power Amplifier CDi Analog 2-1250 (2 channel) Public Address system on the concourse at Flinders Street station OCS Mark Cole Engineering Product Approval Approved 13/03/2015 CDi 2-1250 NA NA Crown by Harman Nil
00090 1Soundwed London BLU-100 Signal Processor (Public
Address)Public Address system on the concourse at Flinders Street station OCS Mark Cole Engineering Product Approval Approved 13/03/2015 BLU-100 NA NA Soundweb London Nil
00089 1 Siemens’ Wayguard DC Shunting Panel
The Siemens Wayguard DC Shunting Enhancer Panel is suitable for:-
• Use with the Siemens Grade Crossing Predictor3000 and 2000
• Trial with the Highway Crossing Processor (HXP3)
Signals Glenn Miller Full Type Approval Approved 13/04/2015 31/10/20158000-80049-0001; 8000-80049-
0005NA NA Siemens Rail Automation Germany
1. Projects shall ensure that appropriate protection from lightning and surges is provided in
accordance with the VRIOGS and the supplier's recommendations.
2. During the test and commissioning of the trail shunt enhancer, a test train shall be used to
ensure the shunt enhancer has not degraded the proper operation of the HPX3 system. Further,
00088 1 Switchguard D150 derail MkII & C150 cwoder MkIIThe derail is used for the protection against run away vehicles, with the crowder component being used to prevent the derailed vehicle from then
becoming “re-railed”Signals Glenn Miller Full Type Approval Superseded NA NA Superseded - Refer to TA 00294
00087 1 Stakkabox
The product is a substitute for the HV concrete pre-cast that weigh 5 tonnes and have a long lead time in procurement.
The product is a range of sectional, modular and structural preformed access chambers (pist). Each chamber is made from 150mm deep
stacking ections which interlock to offer flexibility in finished chamber depths.
Electrical
NetworksTBC Full Type Approval Withdrawn 18/09/2018 NA NA NA IDS
00086 2 Siemens Axle Counters Siemens Clearguard ACM200 Axle Counting System Signals Russell Shield Full Type Approval Approved 20/08/2015 ACM 200 NA NA Siemens Refer to certificate
00085 1 DEHN Spark-gap Overvoltage protection of 1500V DC ApparatusElectrical
NetworksWais Ashory Full Type Approval Approved 10/02/2016
MA SDS M12 (723 199) and
SDS1 (923 110)NA NA
DEHN & SOHNE GmbH
&CoNeumarkt, Germany Nil
00083 1Dual Inventive ZKL3000 and ZKL3000-RC Track Circuit
Operating Devices (TCOD)A TCOD for activating track circuits during planned engineering operations in accordance with Operational Requirements. Signals Russell Shield Full Type Approval Superseded 23/10/2015 31/12/2015 Refer to TA Certificate NA NA Dual Inventive BV Netherlands
00083 2Dual Inventive ZKL3000 and ZKL3000-RC Track Circuit
Operating Devices (TCOD)A TCOD for activating track circuits during planned engineering operations in accordance with Operational Requirements. Signals Russell Shield Full Type Approval Approved 18/12/2015 Refer to TA Certificate NA NA Dual Inventive BV Netherlands Refer to certificate
00082 2 Zöllner Automated Track Warning System Automated mobile track protectionTrack &
StructuresPeter Dohle Full Type Approval Superseded 27/05/2015 Refer to TA Certificate NA NA Zöllner Signal GMBH Germany
00082 3 Zöllner Automated Track Warning System Automated mobile track protectionTrack &
StructuresPeter Dohle Full Type Approval Approved 4/09/2015 Refer to TA Certificate NA NA Zöllner Signal GMBH Germany
• Not approved for use in MURL.
• To be used in accordance with safe working procedure L1-SWS-PRO-016.
00081 2 Clevertronics LED Luminaire MURL Emergency LightingTrack &
StructuresNA Full Type Approval Approved 17/12/2014
LWP2LIFEM-PRO-WPPOD-400-
ZW-4HRN/A N/A Clevertronics Australia Full approval for installatin in MURL
00080 1 Famco Viking LED Luminaire MURL Emergency LightingTrack &
StructuresNA Provisional Type Approval Approved 6/11/2014 30/06/2015 FSP 16773 N/A N/A Famco Lighting PtyLtd Australia Approved for trial in the MURL
00079 1 Hedkote Welding Process Repair of defects in rail and crossingsTrack &
StructuresGordon Djurdjevic Full Type Approval Approved 20/10/2014 N/A N/A N/A N/A N/A
Approved for 6 month trial on Metro Network with performance to be reviewed at the conclusion of
the trial for full Type Approval.
Weld repair to be in accordance with MTM Wire Feed Repair Welding Procedure (MTPR 033100-
11) and Hardface Technologys Hedkote Welding Manual.
00079 2 Hedkote Welding Process Repair of defects in rail and crossingsTrack &
StructuresGordon Djurdjevic Full Type Approval Approved 21/06/2016 N/A N/A N/A Hardface Technology Australia
6 month trial has expired. Re-submission post provisional type approval to full type approval has
been completed and certified. Please refer to the hyperlinked location for description of the
restrictions/conditions/limitations.
Please refer to L1-CHE-PRO-004 for T.A Procedure
Uncontrolled if printed. Controlled by MTM Eng. Systems (OCE)
Page 20 of 22 [email protected]
Metro Trains Melbourne Engineering Approved Product List As of 20/01/2020 (Updated monthly)
TA
NumberIssue Title/Product Function/Application(s)
Applicable
System(s)SME Approval Type Approval Status
Approval/Rejected
DateExpiry
Withdrawal/Suspension
DateType/Model Number
Hardware
Revision No.
Software Version
No.Manufacturer Place of Manufacture Condition and Service Restrictions
00078 1 ARSC 47kg rail Glued joints and fabricated points & V crossingsTrack &
StructuresNA Full Type Approval Superseded 20/10/2014 N/A 47kg NA NA N/A China
Rail not approved for FBW. Separate application will be required to expand the Type Approval to
cover FBW.
00078 2 ARSC 47kg railGlued joints and fabricated points & V crossings
Rail closures for RFD repair in accordance with MTPR 033000-10 – Welded Track Management Manual Chapter 10 – Closure Rails
Track &
StructuresGordon Djurdjevic Full Type Approval Approved 29/09/2015 47kg N/A N/A N/A China
Rail not approved for FBW. Separate application will be required to expand the Type Approval to
cover FBW.
00077 1 53kg Mechanical Insulated Rail Joint Electrical solation of adjacent track sections of jointed rail for the effective operation track circuitsTrack &
StructuresHassan Elaina Provisional Type Approval Withdrawn 17/10/2014 17/10/2015 8/08/2019
53kg Mechanical Insulated Rail
JointNA NA Imtram Pty Ltd Australia
Approved for trial on MTM network. Installation locations to be approved by Head of Engineering –
Track and Structures.
Review of product to be completed at completion of trial period confirming UV compliance, wear
resistance and successful installation of these components during the initial trial.
00076 1 MTR3000 Base Station/Repeater NUTR Radio Base Station OCS NA Full Type Approval In Progress MTR3000 NA NA Motorola
00075 1 Delkor Baseplates TBCTrack &
StructuresNA Full Type Approval In Progress NA NA
00073 1 Robel Rail Clamps Rail Clamps for Mechanical Jointing of Broken RailsTrack &
StructuresHassan Elaina Full Type Approval Approved 4/03/2014 Rail clamp long 68.05 NA NA
ROBEL Bahnbaumaschinen
GmbHGermany
The maximum train speed over the clamp is 80 kph
The clamp should be checked and retightened after one train and then monitored every 72 hours
until removal.
To be stored in dry location to minimise corrosion.
00073 a Robel Rail Clamps Rail Clamps for Mechanical Jointing of New Track Construction, Closure Rails in Existing Track and Rerailing. Track &
StructuresHassan Elaina Provisional Type Approval Approved 26/08/2015 26/09/2015 Rail clamp long 68.05 NA NA
ROBEL Bahnbaumaschinen
GmbHGermany
00073 2 Robel Rail ClampsRail Clamps for Mechanical Jointing of New Track Construction, Closure Rails in Existing Track and Rerailing.
(Updated to include the new procedure L2-TRK-PRO-052 MTM INSTALLATION OF ROBEL 68.05 LONG RAIL CLAMP)
Track &
StructuresHassan Elaina Full Type Approval Approved 21/11/2019 Rail clamp long 68.05 NA NA
ROBEL Bahnbaumaschinen
GmbHGermany
00072 1 Signal Mast Extendable Stand Off Bracket Mitigation of signal sighting issues based on location of signal mast Signals NA Full Type Approval Approved 25/07/2014 DH-2014-005 NA NA DH Engineering Pty. Ltd. Victoria Australia
Future installation to be on case-by-case basis as approved by Head of Engineering Signals & OCS.
Design to prevent mast from extending into Kinematic Envelope.
Only to be used with single signal head units.
00071 1 Milspec Double Skin Location CasesUsed for boxes that is prone to high internal heat increases. (i.e. areas with no adequate shading or boxes that require a large amount of
electronic components)
Electrical
NetworksNA Full Type Approval Approved 27/03/2014 M02737 & M03619 NA NA
Milspec Manufacturing Pty
Ltd
161 – 169 Fallon Street,
Albury, NSW, AustraliaNone
00070 1 Pandrol FASTCLIP FE1400 This product is used to fasten rail to concrete sleepers.Track &
StructuresNA Full Type Approval Approved 11/02/2014 FE1400 NA NA Pandrol Australia Pty Ltd Australia Nil
00069 1 Vision CT12-125X Battery and Charge-X Battery Charger TBCElectrical
NetworksNA Full Type Approval Withdrawn NA NA NA Vision Systems
00068 4 Railduct High Density Polyethylene (HDPE) moulded cable trough system.Track &
StructuresNA Full Type Approval Superseded 27/04/2015 N/A RDUCT NA NA Burdens Northern Ireland Refer to Certificate
00068 5 Cubis Railduct High Density Polyethylene (HDPE) moulded cable trough system.Track &
StructuresNA Full Type Approval Approved 5/04/2016
610003 - Railduct™ cable trough
complete
610001 - Railduct™ cable trough
body only
NA NA Cubis Systems Northern Ireland Refer to Certificate
00067 1 Vossloh Multi Purpose Point Clip Securing of PointsTrack &
StructuresGordon Djurdjevic Full Type Approval Approved 26/08/2015
416.B17266V01
416.B17266V04NA NA Vossloh Cofiger Australia Australia Nil
00066 1 Martinus Rail Turnouts TBCTrack &
StructuresNA Full Type Approval Withdrawn NA NA Martinus Rail
00065 2 Gayrad 50V Regulated Power Supply 110V AC - 50V DC Power SupplyElectrical
NetworksGlenn Miller Full Type Approval Approved 14/12/2017 N/A WQRTJF50/5-R NA NA Gayrad Australia
Provisional for Westrace MkII installation at Mitcham Rooks Road, and made final on 14/12/2017 ,
with NO conditions attached to its use
00064 1Ironcore 11B 2000 M Heavy Duty Transformer Rectifier for
Boom Barriers for 25Hz EnvironmentTransforms 110V AC input to 16V DC Output for Boom Mechanism operations Signals TBC Full Type Approval In Progress
ST/1877 VR/E
11B 2000 M25NA NA Ironcore
Signals
Dept.
00063 1 Schneider PREMSET 15 kV Electrical 2.2kV SupplyElectrical
NetworksAlan Keating Full Type Approval Withdrawn 14/11/2013 31/10/2014 30/10/2017 D02N , I06T with G06 NA NA Schneider France
00062 1 Axle Counter (ELS-95) TBC Signals NA Full Type Approval In Progress NA NA Bombardier Future (Feb 14)
00061 1 Rail Temperature Measuring Equipment TBC Multiple NA Full Type Approval In Progress NA NA Inspired Systems Committed (15/12/2013)
00060 1 Intelligent Infrastructure Management System TBC Multiple NA Full Type Approval In Progress NA NA Thales Future (Feb 14)
00059 1 Steel Hollow Sleepers TBCTrack &
StructuresNA Full Type Approval In Progress NA NA VAE / Contec Future (Jan 14)
00058 1 Cable Plug Couplers TBC Multiple NA Full Type Approval In Progress NA NA Unipart Rail Future (Dec 13)
00057 1 Cable Clips TBC Multiple NA Full Type Approval In Progress NA NA VAE / Contec Committed (Nov 13)
00056 2 GE Tempo Interlocking Urban and mainline applications, configured either as a centralised or distributed CBI/object controller architecture. Signals NA Provisional Type Approval Approved 23/03/2015 31/12/2015
Tempo IXL Baseline 2 hardware
modules and software. Modules
included: VCPU, CPU4, VFCI,
DOLP, DOULP, Bridge, DGN,
NA NA GE Transportation Europe France and Italy
1. The Tempo IXL shall only be installed at the Carrum location for site trial purposes.
2. Power inputs to the Tempo IXL shall be connected such that they will not impact on the upstream
power supply.
3. Signalling inputs to the Tempo IXL shall be connected such that they are non-intrusive to the
00055 1 Axle Counter (ACM200) TBC Signals NA Full Type Approval In Progress NA NA Siemens Future (Dec 13)
00054 1Switch Mode Power Supply (48Vdc, 110Vdc, 24Vdc)
Smartpack Controller and FlatpackSwitch Mode Power Supply to convert from 110VAC or 240VAC to 110VDC and 24VDC
Electrical
NetworksNA Full Type Approval Withdrawn N/A N/A NA
241115.205 Flatpack2 Rectifier
24V, 1800W HE
241115.805 Flatpack2 Rectifier
NA NA Eltek Valere
00053 1 Platform Gap Filler Platform Gap Filler for access to Metro TrainsTrack &
StructuresNA Full Type Approval Approved 9/12/2013 Various NA NA TMT Co. Ltd. China None
00052 2 Marciano Double Skin Location CasesUsed for boxes that is prone to high internal heat increases. (i.e. areas with no adequate shading or boxes that require a large amount of
electronic components),13/02/2018 version 2 has captured the addition sized equipment case and its preferred foundationSignals Glenn Miller Full Type Approval Approved
version one on the
1/04/2014, version 2 on
14/03/2018
N/A
version 1 approved 01/04/2014
MRSC-SC01 - Complete Single
Width Case
MRSC-DC01 - Complete Double
NA NA Marciano Industries12 Century Circuit, Baulkham
Hills, NSW, Australia
Conditions:-
The installation of the cases shall be in accordance with this type approval recommendation
1. That the equipment case shall be installed on site and then interfaced to the site conditions. In
00051 1Vigitron MaxiiCopper Vi22xx series High-Power POE
Midspan:Ethernet switch with high power PoE demand. OCS NA Engineering Product Approval In Progress
Vi2208
Vi2216NA NA Vigitron USA
00050 1 Vi24xx series Ethernet extenders over coax Analogue to Digital CCTV OCS NA Engineering Product Approval In Progress
Vi2401, single port;
Vi2404, four port;
Vi2408, eight port;
Vi2416, sixteen port.
NA NA Vigitron USA
00049 1 SICE Level Crossing TBCTrack &
StructuresNA Full Type Approval In Progress NA NA SICE / Enyce Committed (15/12/2013)
00048 1 Grease Applicators Rail LubricationTrack &
StructuresNA Full Type Approval Withdrawn N/A N/A NA Various NA NA LB Foster
00047 1 KWENA anti-theft conductor cable Spark Gap Overhead Ashley Keep Full Type Approval Withdrawn 12/07/2019 TBC NA NA LECTRO-TECH Type approval withdrawn as advised by SME, refer to attached email in the folder
00046 1 Friction Buffer Stop Buffer Stop For terminal Point ProtectionTrack &
StructuresNA Full Type Approval Approved 31/07/2013
10EB, 10EB M+S, 12 ZEB/5,
16ZEBNA NA A.RAWIE GmbH & Co. Germany As specified on the TA Certificate
00045 1 Junction Fishplates Temporary joining of rail of different weightsTrack &
StructuresNathan Baker Full Type Approval Approved 10/12/2018 NA NA Westray Engineering Australia
00044 1 Rebosio Insulated Arm Bridges and other areas with restricted overhead clearance.Electrical
NetworksNA Full Type Approval Approved 15/07/2013 SC 10181, M01347 and LT1659 NA NA Bonomi Eugenio - Rebosio Italy As specified on the TA Certificate
00043 1 DVTel Mini Dome Camera OCS NA Engineering Product Approval Registered CM-2101-21P NA NA
00042 1 AzLM - multi line Axle Counter Microprocessor based multiple section axle counter v6.4. Signals NA Full Type Approval Superseded 29/11/2013
Computer Software Configuration
Item (CSCI): Server 1.0.21 Patch
23.14
NA NA Thales
00042 2 AzLM - multi line Axle Counter Microprocessor based multiple section axle counter v6.4. Signals NA Full Type Approval Approved 24/05/2016
FieldTrac 6315 AzLM
Microprocessor-Based Multiple
Section Axle Counter v6.4
NA NA Thales Refer to certificate
00041 1 AzLS - single line Axle Counter Signals NA Full Type Approval Withdrawn N/A N/A NAHardware Configuration Item
(CI): 1.0.1NA NA Thales
00040 3 Alstom SIGWAY FEP
Signalling Protocol Convertor.
Alstom SIGWAY FEP is designed to operate in a railway signalling environment. It provides protocol translation facility between the CBI in field,
train control systems and telemetry system.
Signals NA Full Type Approval Approved 28/11/2014 Model: UNO-3084-D23E
Hardware
Configuration
Item (CI): 1.0.1
Computer Software
Configuration Item
(CSCI): Server 1.0.21
Patch 23.14
Alstom Ltd Australia As specified on the TA Certificate
00039 1 Eaton Magnefix MD4 Switchgear Electrical supply to signalling and protection equipment along railway tracks. Signals Wesley Allen Full Type Approval Withdrawn 3/06/2013 N/A 12/07/2016Eaton Holec Magnefix MD4
SwitchgearNA NA Eaton Electric B.V. Hengelo, The Netherlands As specified on the TA Certificate
00037 4 Mechanical Blade Anchor Lock (MBAL) Locking mechanism for staging works as part of turnout InstallationTrack &
StructuresGordon Djurdjevic Full Type Approval
Suspended (Until Further
Notice)3/02/2014
Mechanical Blade Anchor Lock
for Asymmetric Switches,
AS60kg (Drawing A0B17211,
Rev A)
NA NA Vossloh CogiferCastlemaine, Victoria,
AustraliaTrial installation of Mechanical Blade Anchor Lock at South Kensington.
00037 5 Mechanical Blade Anchor Lock (MBAL) Locking mechanism for staging works as part of turnout InstallationTrack &
StructuresMichael Bogan Full Type Approval In Progress TBC NA NA Vossloh Cogifer
Castlemaine, Victoria,
Australia
Please refer to L1-CHE-PRO-004 for T.A Procedure
Uncontrolled if printed. Controlled by MTM Eng. Systems (OCE)
Page 21 of 22 [email protected]
Metro Trains Melbourne Engineering Approved Product List As of 20/01/2020 (Updated monthly)
TA
NumberIssue Title/Product Function/Application(s)
Applicable
System(s)SME Approval Type Approval Status
Approval/Rejected
DateExpiry
Withdrawal/Suspension
DateType/Model Number
Hardware
Revision No.
Software Version
No.Manufacturer Place of Manufacture Condition and Service Restrictions
00036 3 Elsafe Surge Protection Unit(SPU)Signalling System Protection.
Elsafe Surge Protection Unit is designed to protect the electronic and electro-mechanical devices on railway signalling application.Signals TBC Full Type Approval Approved 21/11/2014
555665 and 216600A;
216660, 555220, 216690,
555710, 216600A, 555175
NA NA Elsafe, Australia Australia As specified on the TA Certificate
00035 1 Intelepower CXS48V, 120A Battery Charger Battery charger for 48V dc control systemElectrical
NetworksTBC Full Type Approval Approved 23/05/2013 331019 NA NA
Century Yuasa Batteries Pty
Ltd.
42-46 Dunlop Rd, Mulgrave,
VIC 3170As specified on the TA Certificate
00034 1 161mm2 Contact Wire Overhead traction supply to the 1500 V dc metropolitan railway systemElectrical
NetworksIzy Perona Full Type Approval Approved 28/08/2013 3104004846 NA NA Lamifil, Belgium
BelgiumTrial Installation of Contact Wire
00033 3 Electromagnetic Latched Pedestrian Escape Exit Gate Pedestrian CrossingsTrack &
Structures
Gordon
Djurdjevic/Mark
Meincke
Full Type Approval Approved
Issue 1: 23/7/13
Issue 2: 29/1/14
Issue 3: 4/9/17
Issue 1: 23/1/14
Issue 2: 30/6/14
Issue 3: N/A
Issue 1 - DMS Standard drawing
STD_C0020 Nov 2013
Issue 2 - DMS Standard drawing
STD_C0035 May 2016
NA NADMS Standard drawing
STD_G0305Australia
Trial Installation at Lilydale up end platform station access for a 6 month operations of
Electromagnetic Escape Exit Gate Arrangement.
Improved gate post design and 1600mm high gate and push button panel adopted for the network.
00032 1 Heinemann F35D200Y 110V Signalling Power Isolation; SUN534SEH Signals TBC Engineering Product Approval Withdrawn N/A N/A NA F35D200Y NA NA Heinemann ??? Not specified as at this time
00031 1 Heinemann F35D160Y 110V Signalling Power Isolation; SUN534SEH Signals TBC Engineering Product Approval Withdrawn N/A N/A NA F35D160Y NA NA Heinemann ??? Not specified as at this time
00030 1 Unipart Dorman LED Possession Limit BoardBoard/sign (i.e. visible marker) installed on the rail head to mark the limit of an Absolute Occupation with a large, reflective STOP sign and a
flashing red LED light.
Track &
StructuresTBC Provisional Type Approval Approved 6/03/2013 5/09/2013 PLB6N/RR/01/001 NA NA Unipart Dorman Nil
00029 1 100 Series Fastening Used in combination with LPCS for resleepering, track constructionTrack &
StructuresGordon Djurdjevic Full Type Approval Approved 24/04/2014
Clip Housing - SRM-100-SHD-
001
Clip - SRM-100-CLP-001
Pad - SRM -100-PAD-001
NA NAANYANG RAILWAY
PRODUCT COChina Only to be used with SINO Sleepers
00028 1 Low Profile Concrete Sleepers Re-sleepering, track constructionTrack &
StructuresGordon Djurdjevic Full Type Approval Approved 24/04/2014 SRM-LPCS-001 NA NA
LECHANGSHI ANJIE
RAILWAY SLEEPER COChina Only to be used with SINO Rail Fastening
00027 2 PZH AS60kg Standard Carbon New Work, Maintenance and Renewal of Track.Track &
StructuresGordon Djurdjevic Full Type Approval
Suspended (Until Further
Notice)27/08/2013 AS60kg Standard Carbon NA NA
Panzhihua Steel and
Vanadium Co. Ltd.Panzhihua, China Type Approval suspended until further notice
00026 2 UniPart Rail Hollow Sleeper Assembly Cable containment where local cables are required to be placed under tracks. Track &
Structures
Gordon
Djurdjevic/Russell
Shield
Full Type Approval Superseded 19/05/2015 19/08/2015Hollow Sleeper 1600 (full depth)
and 1700 (shallow depth) seriesNA NA Trackwork Limited. United Kingdom As specified on the TA Certificate
00026 3 UniPart Rail Hollow Sleeper Assembly Cable containment where local cables are required to be placed under tracks. Track &
Structures
Gordon
Djurdjevic/Russell
Shield
Full Type Approval Superseded 1/09/2015 30/11/2015Hollow Sleeper 1600 (full depth)
and 1700 (shallow depth) seriesNA NA Trackwork Limited. United Kingdom As specified on the TA Certificate
00026 4 UniPart Rail Hollow Sleeper Assembly Railway signal or communication cables containment where local cables are required to be placed under tracksTrack &
Structures
Gordon
Djurdjevic/Russell
Shield
Full Type Approval Superseded 6/10/2015Hollow Sleeper 1600 (full depth)
and 1700 (shallow depth) seriesNA NA
Trackwork Limited/Unipart
Rail AustralasiaUnited Kingdom As specified on the TA Certificate
00026 5 UniPart Rail Hollow Sleeper Assembly Railway signal or communication cables containment where local cables are required to be placed under tracksTrack &
Structures
Gordon
Djurdjevic/Russell
Shield
Full Type Approval Approved 25/06/2016Hollow Sleeper 1600 (full depth)
and 1700 (shallow depth) seriesNA NA
Trackwork Limited/Unipart
Rail AustralasiaUnited Kingdom As specified on the TA Certificate
00025 2 2000R/AF Impedance BondTrack Circuits/ Traction application for 50Hz/AC
or Audio Frequency Track Circuits (CSEE)Multiple TBC Full Type Approval Approved 3/02/2014 SDM 2000 NA NA Sulzer Dowding and Mills Laverton, Victoria, Australia Not specified as at this time
00024 1 Westlock CBI S1.05 Computer Based Interlocking system. Signals TBC Full Type Approval Approved 26/02/2013 WESTLOCK/S1.05 NA NA Invensys Rail UK United Kingdom Nil
00022 1 Railway Type 1 Pit & Lid / UG2078Plastic pits can be used as an alternative to traditional concrete pits, for access to cable routes for signalling, communication and power cables.
Plastic pits can also be used as turning chambers where cable routes require a change of direction (of more than 45 degrees).Multiple TBC Full Type Approval Approved 5/03/2013
Railway Type 1 Pit & Lid /
UG2078NA NA
Viscount Rotational
Moulding Pty. Ltd.
81 Frankston Gardens Drive,
Carrum Downs, Vic 3201As specified on the TA Certificate
00021 1 VRM Plastic Ground Level Trough (GLT)Plastic GLT can be used as an alternative to traditional concrete or metal GLT to route signalling, communication and power cables. Moulded
barriers within the trough allow separation of services and types of cables such as communication and HV cables.Multiple Gordon Djurdjevic Full Type Approval Superseded 5/03/2013
Cable Tray (GLT)/UG2072
Cable Tray Lid (GLT lid) /UG2071NA NA
Viscount Rotational
Moulding Pty. Ltd.
81 Frankston Gardens Drive,
Carrum Downs, Vic 3201As specified on the TA Certificate
00021 2 VRM Plastic Ground Level Trough (GLT)Plastic GLT can be used as an alternative to traditional concrete or metal GLT to route signalling, communication and power cables. Moulded
barriers within the trough allow separation of services and types of cables such as communication and HV cables.Multiple Gordon Djurdjevic Full Type Approval Approved 8/10/2015
Cable Tray (GLT)/UG2072
Cable Tray Lid (GLT lid) /UG2071NA NA
Viscount Rotational
Moulding Pty. Ltd.
81 Frankston Gardens Drive,
Carrum Downs, Vic 3201As specified on the TA Certificate
00019 1 Overhead Tram Square Fitting Overhead Tram Square Crossing fitting Overhead Izy Perona Grandfather Rights Approved NA FDX Crossing NA NA Arthur Flury Switzerland Max speed 40km/h
00018 3 Alpha Power System UPS 3kVA full on line UPS (48V and 96V DC Variants) Signals
Matthew
DeGabrielle/Noel
Arandt
Full Type Approval Approved 1/05/2014
CFRTU 6103/SR (48V DC
Version) and CFRTU 6103 (96V
DC Version)
MATS002/110/C - Bypass Switch
NA NA Alpha Power Systems China
00017 1 Edilon Sedra Embedded Rail System (ERS) Level crossing renewalsTrack &
StructuresGordon Djurdjevic Provisional Type Approval Approved 7/08/2015 30/06/2016 Edilon LC-H / LC-L NA NA Edilon Sedra Australia Not specified as at this time
00017 1 Edilon Sedra Embedded Rail System (ERS) Level crossing renewalsTrack &
StructuresGordon Djurdjevic Full Type Approval Approved 27/05/2019 Edilon LC-H / LC-L NA NA Edilon Sedra Australia Not specified as at this time
00015 1 Hascom Serial IO MkII PRIDE telemetry (Railmasters) track indications (train movement) back to PRIDE OCS Mark Cole Engineering Product Approval Approved 27/11/2012 P/N 025001 NA NAHASCOM International Pty
Ltd
00014 1 Train Protection Warning System Railway Signalling Equipment - Train Protection Warning System. Signals NA Full Type Approval Approved 2/03/2012 Thales TPWS Refer to certificate
00013 1 Front End Processor (FEP) TBC Signals NA Full Type Approval Withdrawn N/A N/A NA Alstom
00012 1 ACM 100 Axle Counter Track Vacany Detection Signals TBC Full Type Approval Withdrawn N/A N/A NA ACM 100 Siemens Germany Germany As specified on the TA Certificate
00011 1 EcoStar In Bearer points Points/Turnout Operation utilising Rail Head lockingTrack &
StructuresTBC Full Type Approval Approved NA VAE Systems Austria As specified on the TA Certificate
00010 2 UniStar In Bearer points Points/Turnout Operation utilising machine lockingTrack &
Structures
Gordon
Djurdjevic/Russell
Shield
Full Type Approval Superseded N/A N/A CONTEC Gmbh Austria As specified on the TA Certificate
00010 4 UniStar In Bearer points Points/Turnout Operation utilising machine lockingTrack &
Structures
Gordon
Djurdjevic/Russell
Shield
Full Type Approval Approved 20/11/2015 Refer to TA Certificate NA NA CONTEC Gmbh Austria As specified on the TA Certificate
00009 1 SpheroLock Point Locking Mechanism Rail Head point locking mechanism Signals TBC Full Type Approval Approved NA VAE Systems Australia As specified on the TA Certificate
00008 1 RailAsset Monitor Signal Equipment Monitoring Signals TBC Full Type Approval Approved NA N/A Siemens Australia Germany
00007 1 Siemens S 700 V(A) In Bearer Points Points/Turnout Operation Signals David Woodcock Full Type Approval Approved 20/01/2012 S 700 V(A) Siemens Australia Germany As specified on the TA Certificate
00006 1 Tilting MastSpecially designed mast which allows maintenance work to be carried out on the mast at ground level eliminating the risks of working at heights
and in close proximity to overhead high voltage power linesSignals Bryan Lai Full Type Approval Approved 20/02/2012
Rail Industry Constructions
Pty Ltd., Mayfiedl West,
NSW, Australia
Unit 15, 5-7 Channel Road,
Steel Industrial Estate, Rail
Industry Constructions Pty
Ltd., Mayfiedl West, NSW,
Australia
As specified on the TA Certificate
00005 1 Continuous Earth Leakage Detector To detect earth leakage to any conductor directly connected a power distribution systemElectrical
NetworksNA Full Type Approval Approved 10/02/2012
MRD-ELD-AC/DC-AUTO-110
Earth Leakage Detector Auto
Monotoring Busbar 0-650V AC or
12V-150VDC fault Contact, Item
MRD Rail Technologies Pty;
Cleveland, Queensland
4163, Australia
235 South Street, Cleveland,
Queensland 4163, AustraliaAs specified on the TA Certificate
00004 1 AZ S 350U Axle Counter Track Vacany Detection Signals NA Full Type Approval Approved 5/04/2012 AZ S 350U Axle Counter Siemens Germany Germany As specified on the TA Certificate
00003 2 Computer Base Interlocking Westrace MK II Computer Based Interlocking system. Signals Russell Shield Full Type Approval Approved 31/05/2016 Westrace MK II Siemens United Kingdom Nil
00002 1 Computer Base Interlocking Westrace MK II Computer Based Interlocking system. Signals NA Full Type Approval Superseded 19/02/2013 Westrace MK II Invensys Rail UK United Kingdom Nil
00001 1 Track Circuit ET200 Railway Signalling Equipment - For Train Detection Signals Francis Hui Full Type Approval Approved 8/03/2012EBI Track 200 (TI21) Audio
Frequency Track Circuit
Bombardier Transportation;
UK LtdUnited Kingdom Not specified as at this time
Please refer to L1-CHE-PRO-004 for T.A Procedure
Uncontrolled if printed. Controlled by MTM Eng. Systems (OCE)
Page 22 of 22 [email protected]