Transcript
Page 1: Method a - Water Wash Fluorescent Inspection (1)

PRECLEAN WITH DARACLEAN APPLY PENETRANT DWELL TIME

10-30 Minutes(in some cases longer)

RINSE

50 - 100°F (10 - 38°C)at <40 psi

APPLY AQUEOUS DEVELOPER DRY

at 140°F (60°C)

DWELL TIME

10 min. - 2 hrs. max.

DRY

at 140°F (60°C)

APPLY DRY DEVELOPER DWELL TIME

10 min. - 4 hrs. max.

INSPECT

Method A: WATER WASH FOR FLUORESCENT INSPECTION

DCN-282 Aerospace

DCN-200 Non-Spec

DCN-236 Neutral

ZL-15B Level 1/2ZL-19 Level 1ZL-60D Level 2ZL-67 Level 3ZL-56 Level 4

ZP-5B

Water Suspendible

ZP-4B

Dry Developer

A Division of Ill inois Tool Works Inc.

7

PENETRANT PROCESS GUIDE

MAGNAFLUX . 3624 West Lake Avenue . Glenview, Illinois 60026 . (847) 657-5300 . [email protected] . www.magnaflux.com

Recommended