Transcript
Page 1: Magnetic Property Measurement System MPMS XL. Configurations MPMS XL is offered in 2 configurations MPMS XL-5 (5 Tesla) MPMS XL-7 (7 Tesla)

Magnetic Property Measurement Magnetic Property Measurement SystemSystem

MPMS XLMPMS XL

Page 2: Magnetic Property Measurement System MPMS XL. Configurations MPMS XL is offered in 2 configurations MPMS XL-5 (5 Tesla) MPMS XL-7 (7 Tesla)

ConfigurationsConfigurations

MPMS XL is offered in 2 configurationsMPMS XL is offered in 2 configurations

MPMS XL-5 (5 Tesla)MPMS XL-5 (5 Tesla)

MPMS XL-7 (7 Tesla)MPMS XL-7 (7 Tesla)

Page 3: Magnetic Property Measurement System MPMS XL. Configurations MPMS XL is offered in 2 configurations MPMS XL-5 (5 Tesla) MPMS XL-7 (7 Tesla)

Principal components of this measurementmeasurement system

Temperature Control System ( 1.7 K to 400 K)

Magnet Control System ( ± 5 T)

Sample Handling System

Computer Operating System

Super conducting SQUID Amplifier System

Page 4: Magnetic Property Measurement System MPMS XL. Configurations MPMS XL is offered in 2 configurations MPMS XL-5 (5 Tesla) MPMS XL-7 (7 Tesla)

1. Sample rod

2. Sample rotator

3. Sample transport

4. Probe assembly

5. He level Sensor

6. Superconducting Solenoid

7. Flow Impedance

8. Squid capsule with magnetic shield

9. Superconducting pick-up coil

Page 5: Magnetic Property Measurement System MPMS XL. Configurations MPMS XL is offered in 2 configurations MPMS XL-5 (5 Tesla) MPMS XL-7 (7 Tesla)

10. Dewar Isolation cabinet

11. Dewar

12. Printer

13. Magnetic power supply

14. Temp. controller

15. Console Cabinet

16. Power distribution unit

17.MPMS controller

18. Gas/Magnet control

unit

19. Computer

20. Monitor

Page 6: Magnetic Property Measurement System MPMS XL. Configurations MPMS XL is offered in 2 configurations MPMS XL-5 (5 Tesla) MPMS XL-7 (7 Tesla)
Page 7: Magnetic Property Measurement System MPMS XL. Configurations MPMS XL is offered in 2 configurations MPMS XL-5 (5 Tesla) MPMS XL-7 (7 Tesla)

Specifications of MPMS XL-5Specifications of MPMS XL-5

Field =5 TeslaField =5 TeslaTemperature=1.7K to 400 KTemperature=1.7K to 400 K

Sweeping rate=0.001K to 10K/MinSweeping rate=0.001K to 10K/Min

Page 8: Magnetic Property Measurement System MPMS XL. Configurations MPMS XL is offered in 2 configurations MPMS XL-5 (5 Tesla) MPMS XL-7 (7 Tesla)

Possible MeasurementsPossible Measurements

Magnetization vs. Temperature (M vs. Magnetization vs. Temperature (M vs. T):T):Default settings: Default settings: 300K-10K300K-10K, Temperature interval , Temperature interval 5K5K

Zero Field CoolingZero Field Cooling Field Cooling Field Cooling

AC Susceptibility AC SusceptibilityMagnetization vs. Field (M vs. H):Magnetization vs. Field (M vs. H):Default settings: Default settings:

-5T to +5T -5T to +5T step size step size 0.5T0.5T Hysteresis Hysteresis

HysteresisHysteresis

Page 9: Magnetic Property Measurement System MPMS XL. Configurations MPMS XL is offered in 2 configurations MPMS XL-5 (5 Tesla) MPMS XL-7 (7 Tesla)

Features of MPMS MultiVu Features of MPMS MultiVu SoftwareSoftware

Simultaneous Access to all aspects of system operation: Simultaneous Access to all aspects of system operation: sequence setup,data analysis,data displaysequence setup,data analysis,data display

Enables multiple documents and view to be visible and useable Enables multiple documents and view to be visible and useable at the same timeat the same time

Simultaneous display of data files in multiple formats (e.g.. Simultaneous display of data files in multiple formats (e.g.. Graphs vs. texts)Graphs vs. texts)

Automated Background SubtractionAutomated Background Subtraction

Page 10: Magnetic Property Measurement System MPMS XL. Configurations MPMS XL is offered in 2 configurations MPMS XL-5 (5 Tesla) MPMS XL-7 (7 Tesla)

SQUI D Magnetometer Facility (Division of Chemical Sciences)

Request Form: Date of Submission: Sample name: Email Id: Phone No: Experiment details: 1.Magnetisation Vs Temperature (M vs. T) Temperature Range (Default settings: 300K-10K, Temperature interval 5K): Magnetic Field (0-5T): (Typical measurement time for default settings: 7hours) 2.Magnetisation Vs Field (M vs. H) Field (Default settings: -5T to +5T step size 0.5T): Temperature: (Typical measurement time for default settings: 6hours) Note: If you require M vs H measurement at more than two temperatures, please submit a separate request form. Signature of the Research Supervisor

OPERATORE’S USE

Time taken : Date of completion:

Page 11: Magnetic Property Measurement System MPMS XL. Configurations MPMS XL is offered in 2 configurations MPMS XL-5 (5 Tesla) MPMS XL-7 (7 Tesla)

LimitationsLimitations

•Measurement of hysteresis at more than two Measurement of hysteresis at more than two temperatures is considered as II sampletemperatures is considered as II sample

•Measurement below 10K also considered as II Measurement below 10K also considered as II sample (because it is necessary for the instrument to sample (because it is necessary for the instrument to

be stable at 10K at least for 1 hour before going be stable at 10K at least for 1 hour before going below 10K)below 10K)

•Sample should be submitted only on FridaySample should be submitted only on Friday

Page 12: Magnetic Property Measurement System MPMS XL. Configurations MPMS XL is offered in 2 configurations MPMS XL-5 (5 Tesla) MPMS XL-7 (7 Tesla)

Total Number of Measurements DoneTotal Number of Measurements Done

Total Number of Working days =Total Number of Working days = Total = Total = Physics = Physics = SSCU = SSCU = MRC = MRC = ISU = ISU = Metallurgy = Metallurgy = Outside = Outside = IPC =IPC =