M3200.0562
SLF 51 to SLF 75
Weitergabe sowie Vervielfltigung dieser Dokumente, Verwertung und Mitteilung seines Inhalts sind
verboten, soweit nicht ausdrcklich gestattet. Z uwiderhandlungen verpflichten zu Schadenersatz. Alle
Rechte fr den Fall der Patent-, Gebrauchsmuster- oder Geschmacksmustereintragung vorbehalten.
The reproduction, distribution and utilization of this documents as well as the communication of its contents
to others without expressed authorization is prohibited. Offenders will be held liable for the payment of damages .
All rights reserved in the event of the grant of patent, utility model or ornamental design registration.
www.boge.com
This drawing was made with CAD. Valid without signatureund ist ohne Unterschrift gltig.
Diese Zeichnung wurde mit CAD erstellt
drawing number
respons.
proofed
processed
replacement byreplacement for
of sheets
Ers.d.:Ers.f.:
Zeichnungsnummer
Bl.
Freigabe
Bearb.
Zust.
identification number
name
material:scaleWst.:Mastab
Urspr./origin
Benennung/designation
Identnummer
NURMITCADAENDERN/MODIFIY
ONLYWITHCAD
Blatt/sheet
Name/nameDatum/Date
NameDatum / datenderung / modification
Solid Edge
2
1
1 : 20
J. Wittland
Supply
air
Supply air
possible
Exhaust air
supersilenced
Exhaust
air
silenced
Supply air
Supply air possible
Compressed air
outlet G1 1/2
924
1090
920 700
1700
2040
87
97
150
1950
(supersilence
d)
800
min.
A
Detail A1:10
1450
(sile
nced)
1. Weight silenced / supersilenced
2. The static loads below the permissible
values according to VOB !
3. Hot air quantity
4. Fan capacity required for
compressor room ventilation
5. Supply air opening required
(if blind or similar equipment
mounted, openings must
be approx. 20% larger)
6. Water connection only for version "Duotherm integrated"
7. Only supersilenced and/or with supply/exhaust air duct
} acc. to VDMA-standard sheet 43637.)
80
0
min.
773
580
580
100
160
100
370
64
100
140
36
electrical connection
Water OUT G1
Water IN G1
Mounting possibilityfor supply air flangeor air inlet filtration (option)
6.)
400min.
400
min.
1200 1
000 700
70
200
160
8.)
6.)
25
20
50
Mounting possibilityfor supersilencedexhaust air flange
Mounting possibility forsilenced exhaust air flange
8.)
Maintenanceclearance
safe
clearance
acc.
to
VDE
0100
section
729
Maintenanc
e
clearance1) 2) 3) 4) 5)Anlage kg N/cm m/h m/h m
SLF 51 1020 / 1070 32 / 34 5500 11000 1,4SLF 61 1150 / 1200 36 / 37 6500 13000 1,6SLF 75 1270 / 1320 40 / 41 7000 14000 1,8
20
45
SLF-range air cooled
silenced and supersilenced version
6.)
1290
110
50
74
All rights reserved for technical changes !
Recommended