Transcript
Page 1: LX25, LX5, LX5 SERIES - Solar Vision Inc. · 2020. 8. 27. · LX25, LX5, LX5 SERIES - 3 info@vision-solaire.com T. 1-819-729-0450 Révision: 2.4 1.2 STORAGE AND HANDLING: If you wish

LX25, LX50, LX95 SERIES

Manufactured by:Vision Solaire [email protected]. 1-819-729-0450

Révision: 2.4

IMPORTANT NOTES:• Alwaysinstallthelightingfixtureonthepolebeforeinstallingthebattery.• Thelightingfixtureshouldneverbehandledwithbatteryinstalledinside.• Thebatterycompartmentcontainsa“quickconnector”toconnectthebattery,identifiedas“BATTERY”.• Thebatterycompartmentalsocontainstwoadditionalwiresmarked“EXTERNAL SOLAR PANEL *OP-

TIONAL* “.Thesetwowiresmustneverbeconnectedtothebattery,theyareusedwhenanadditionalexternalsolarpanelisinstalled.

INSTALLATION1. Installthelightingfixtureonapolewithanouterdiameterof:

• 101mm(4in)fortheLX25andLX50(roundorsquaresleeveisavailableforLX25,LX50);• 127mm(5in)LX95(squaresleeveonlyontheLX95);

2. Slidethelightingfixtureontopofthepole;3. Usethe1/4”-20bolttosecuretheluminairetothepole,choosethedrillingpatternaccordingtoyourmodel

(LX25-50orLX95);4. Oncethelightisinplace,openthebatteryboxdoorandinsertthebattery.Thebatteryisstandingupforthe

LX95.ThebatteryislyingonitssidefortheLX25andLX50asshowninthefiguresbelow;5. Makeaquickconnectionwiththequickconnectcable;6. Agreenindicatorlightindicatesthattheluminaireisfunctionnal.7. Closethebatteryboxdoor,theinstallationisnowcomplete.

LEARNING DELAYThelightrequiresa24-hourdelaytooperateproperlyaccordingtoit’sprogram.

STEP 1, 2, 3

STEP 4 STEP 5

Indicatorlights

Page 2: LX25, LX5, LX5 SERIES - Solar Vision Inc. · 2020. 8. 27. · LX25, LX5, LX5 SERIES - 3 info@vision-solaire.com T. 1-819-729-0450 Révision: 2.4 1.2 STORAGE AND HANDLING: If you wish

LX25, LX50, LX95 SERIES

Manufactured by:Vision Solaire [email protected]. 1-819-729-0450

Révision: 2.4

SolarModuleOrientation Period Autonomy

losses

South(≈optimal)

Annual 0%

Summer 0%

Winter 0%

East/West

Annual -17%

Summer -9.8%

Winter -28%

North

Annual -35.8%

Summer -21.6%

Winter -54.8%

ORIENTATION AND AUTONOMY 1.1INSTALLATIONGUIDELINESToavoidalossofautonomyandamalfunction:• Theluminairemustbeinstalledhorizontallyandmustneverbetilted;• Theluminairemustbeinstalledattheendofthepost;• Theluminairemustbeinstalledinanopenspacewithnotreesorstructures

nearby,thiscouldfavoursnowaccumulationandshading;• Thesolarmodulemustbeideallyorientedtowardsthesouth,otherwisesee

table“ORIENTATIONANDAUTONOMY”.Failingtofollowtheserecommendationscanresultinlossofsystemperformance.FACTORSAFFECTINGAUTONOMY:Lackofsunshine,verylowambienttemperature,snowaccumulationduetotreesor structures nearby, shading due to nearby trees or structures, solarmoduleorientation(seetable),toomanyunplannedoccupancydetections(road,unusualactivitiesandevents),sunshinebelowthemonthlyaverages,timedelaytoohighontheoccupancysensor.

Page 3: LX25, LX5, LX5 SERIES - Solar Vision Inc. · 2020. 8. 27. · LX25, LX5, LX5 SERIES - 3 info@vision-solaire.com T. 1-819-729-0450 Révision: 2.4 1.2 STORAGE AND HANDLING: If you wish

LX25, LX50, LX95 SERIES

Manufactured by:Vision Solaire [email protected]. 1-819-729-0450

Révision: 2.4

1.2STORAGEANDHANDLING:Ifyouwishtostoretheluminaire,thebatteryneedstoberechargedbeforestor-ingforaperiodof15daysormoreinordertopreventdamagetothebattery.Theluminairemustbestoredat20°Croomtemperature.Theluminaireshouldneverbemanipulatedwhenthebatteryisinside.Usethequickaccessdoortoremovethebatterybeforehandling.1.3DEEPDISCHARGEPROTECTIONThisprotectionsignificantly increasesbattery lifespan.Thisprotectionalsopre-ventspermanentdamagetothebatterycausedbyverydeepdischargesduringcoldweather.Whenthebatteryreachesa50%stateofcharge,thebatteryisautomaticallydisconnectedfromthesystemuntilit’sstateofchargereach-es85%i.e.about1dayofsunshineinsummerandabout4daysofsunshineinwinter.1.4PIRSENSORTIMEDELAYFEATUREADJUSTMENTPleasebecareful,thetimedelaytrimpotisafragilecomponent.TheTimeDelay(30secondsto30minutes)adjustmenttrimpotislocatedunderthelensassembly.Thetrimpotisaccessedeasily.Gentlyunscrewthelensas-sembly.Donotremovethethumbscrewcollar;itholdsthesensorinplaceonthefixture. Setthetimedelaytothedesiredsetting.Thetimedelaycanbesetfrom30seconds(fullycounterclockwise) to30minutes(fullyclockwise).Werecom-mendnottogoover5minutes.Thetimedelaystartswhennomorepresenceisdetected.1.5DAY-NIGHTTRANSITIONThefixtureusesthesolarpaneltodetectdayandnightperiods.Thenighttransi-tionrequiresaverylowbrightnesslevelfor5continuousminutes.Thisconstraintpreventsfalsenighttransitions.Avoidexposingtheluminairetoanartificiallightsourcethatmaycausesynchronizationerrorsbysimulatingtheday.Ifthefixtureoperates erratically,make sure the solarmodule is not coveredwith debris orheavysnow.Theluminaireautomaticallycorrectssynchronizationerrorsafter24hours.Theoccupancysensorhasitsownphotocell,whichdoesnotactivatewhentheambientbrightnessistoohigh.

Page 4: LX25, LX5, LX5 SERIES - Solar Vision Inc. · 2020. 8. 27. · LX25, LX5, LX5 SERIES - 3 info@vision-solaire.com T. 1-819-729-0450 Révision: 2.4 1.2 STORAGE AND HANDLING: If you wish

B 2

.00

3.0

0

TYP

. .3

5

1.0

0

DET

AIL

BSC

ALE 1

: 3

NO

TE:

The

inst

alla

tion

of

the

lam

p o

n th

e to

p o

f the

pos

t re

qui

res d

rillin

g th

e p

ost a

s per

the

pre

sent

ed d

rillin

g p

attu

rn.

The

lam

p

will

be

secu

red

us

ing

one

bol

t th

roug

h th

e la

mp

p

ost.

The

hole

s sho

uld

be

poin

ting

in th

e d

irect

ion

of th

e d

esire

d o

rient

atio

n.

DIR

ECTIO

N O

F LI

GH

TING

REV

.D

ESC

RIPT

ION

DA

TEPA

R1

UPD

ATE

OF

THE

NO

TE26

MA

R 20

20JF

OL

AA

BB

22

11 4 IN

PO

ST D

RILL

ING

PA

TTER

N L

X25

/ LX

50 1D

O N

OT

SCA

LE D

RAW

ING

LX25

-02-

ENSH

EET 1

OF

1

24 M

AY

19

24 M

AY

19JF

OL

JFO

L

UNLE

SS O

THER

WIS

E SP

ECIF

IED

:

SCA

LE: 1

:5W

EIG

HT:

REV

DW

G N

O.

ATITTL

E

NA

ME

DA

TE

PRO

PRIE

TARY

AN

D C

ON

FID

ENTIA

L

Q.A

.

MFG

APP

R.

ENG

APP

R.

CHE

CKE

D

DRA

WN

FIN

ISH

MA

TERI

AL

INTE

RPRE

T G

EOM

ETRI

CTO

LERA

NC

ING

PER

:

DIM

ENSI

ON

S A

RE IN

INC

HES

TOLE

RAN

CES

:A

NG

ULA

R:

1

TWO

PLA

CE

DEC

IMA

L

0.6"

THRE

E PL

AC

E D

ECIM

AL

0.

31"

HOLE

S:

0.05

"

THE

INFO

RMA

TION

CO

NTA

INED

IN T

HIS

DRA

WIN

G IS

THE

SO

LE P

ROPE

RTY

OF

SOLA

R V

ISIO

N.

AN

Y RE

PRO

DUC

TION

IN

PART

OR

AS

A W

HOLE

WITH

OUT

THE

W

RITT

EN P

ERM

ISSI

ON

OF

SOLA

R V

ISIO

N IS

PR

OHI

BITE

D.

CO

MM

ENT

SIZE

Page 5: LX25, LX5, LX5 SERIES - Solar Vision Inc. · 2020. 8. 27. · LX25, LX5, LX5 SERIES - 3 info@vision-solaire.com T. 1-819-729-0450 Révision: 2.4 1.2 STORAGE AND HANDLING: If you wish

B 2

.500

1.2

50

5.1

25

TYP

. .3

5

DET

AIL

BSC

ALE 1

: 3

NO

TE:

The

inst

alla

tion

of

the

lam

p o

n th

e to

p o

f the

pos

t re

qui

res d

rillin

g th

e p

ost a

s per

the

pre

sent

ed d

rillin

g p

attu

rn.

The

lam

p

will

be

secu

red

us

ing

one

bol

t th

roug

h th

e la

mp

p

ost.

The

hole

s sho

uld

be

poin

ting

in th

e d

irect

ion

of th

e d

esire

d o

rient

atio

n.

DIR

ECTIO

N O

F LI

GH

TING

REV

.D

ESC

RIPT

ION

DA

TEPA

R1

UPD

ATE

OF

THE

NO

TE26

MA

R 20

20JF

OL

AA

BB

22

11 5 IN

PO

ST D

RILL

ING

PA

TTER

N L

X95

1D

O N

OT

SCA

LE D

RAW

ING

LX95

-02-

ENSH

EET 1

OF

1

30 M

AY

19

30 M

AY

19JF

OL

JFO

L

UNLE

SS O

THER

WIS

E SP

ECIF

IED

:

SCA

LE: 1

:5W

EIG

HT:

REV

DW

G N

O.

ATITTL

E

NA

ME

DA

TE

PRO

PRIE

TARY

AN

D C

ON

FID

ENTIA

L

Q.A

.

MFG

APP

R.

ENG

APP

R.

CHE

CKE

D

DRA

WN

FIN

ISH

MA

TERI

AL

INTE

RPRE

T G

EOM

ETRI

CTO

LERA

NC

ING

PER

:

DIM

ENSI

ON

S A

RE IN

INC

HES

TOLE

RAN

CES

:A

NG

ULA

R:

1

TWO

PLA

CE

DEC

IMA

L

0.6"

THRE

E PL

AC

E D

ECIM

AL

0.

31"

HOLE

S:

0.05

"

THE

INFO

RMA

TION

CO

NTA

INED

IN T

HIS

DRA

WIN

G IS

THE

SO

LE P

ROPE

RTY

OF

SOLA

R V

ISIO

N.

AN

Y RE

PRO

DUC

TION

IN

PART

OR

AS

A W

HOLE

WITH

OUT

THE

W

RITT

EN P

ERM

ISSI

ON

OF

SOLA

R V

ISIO

N IS

PR

OHI

BITE

D.

CO

MM

ENT

SIZE


Recommended