Transcript
Page 1: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

DIY Storage System Guidance Using Intel® Server RAID Controllers

Deployment Practices White Paper

Revision 1.0

April 2009

Enterprise Platforms and Services Division - Marketing

Page 2: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

Revision History DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper

Revision 1.0

ii

Revision History

Date Revision Number Modifications April 2009 1.0 Initial release.

Disclaimers

Information in this document is provided in connection with Intel® products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Intel products are not intended for use in medical, life saving, or life sustaining applications. Intel may make changes to specifications and product descriptions at any time, without notice.

Designers must not rely on the absence or characteristics of any features or instructions marked "reserved" or "undefined." Intel reserves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them.

The DIY Storage System Guidance Using Intel® Server RAID Controllers may contain design defects or errors known as errata which may cause the product to deviate from published specifications. Current characterized errata are available on request.

Intel, Pentium, Celeron, and Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries.

Copyright © Intel Corporation 2009. Portions Copyright © LSI Corporation 2009 and Chenbro Corporation 2009.

*Other brands and names may be claimed as the property of others.

Page 3: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper Table of Contents

Revision 1.0 iii

Table of Contents

1. Welcome................................................................................................................................ 1

2. Hardware Components ........................................................................................................ 2

3. Chenbro* RM31616 Chassis Introduction.......................................................................... 3

4. Set up the Storage Hardware System................................................................................. 5

4.1 Server Board Connector and Component Layout.................................................... 5

4.2 Board Front Panel Connector .................................................................................. 7

4.3 Connection between Chassis and Server Board ..................................................... 8

4.4 RAID Controller Installation ..................................................................................... 8

4.5 Backplane Setup and Cable Connection ................................................................. 9

4.6 Using Enterprise-class Drives................................................................................ 10

5. Setup Array using an Intel® RAID Controller ................................................................... 12

5.1 Basic Introduction of RAID Setting for Performance Optimizing............................ 12

5.1.1 RAID Level............................................................................................................. 12

5.1.2 Stripe Size ............................................................................................................. 13

5.1.3 Tuning Controller Cache Options .......................................................................... 13

5.1.4 Hard Disk Cache.................................................................................................... 14

5.2 RAID Configration Demo for Applications.............................................................. 14

6. Advanced Data Integrity Protection.................................................................................. 48

6.1 Using a RAID Controller Battery ............................................................................ 48

6.2 Using a UPS for Power Loss Protection ................................................................ 48

7. Summary ............................................................................................................................. 49

Page 4: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

List of Figures DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper

Revision 1.0

iv

List of Figures

Figure 1. Chenbro* RM31616 Chassis ......................................................................................... 4

Figure 2. Intel® Workstation Board S5000XVN Layout ................................................................. 5

Figure 3. Inserting the Intel® RAID Controller SRCSASPH16I into a PCI Express* Slot .............. 9

Figure 4. Switches on the Backplane with Default Setting............................................................ 9

Figure 5. Backplane Wiring Illustration ....................................................................................... 10

Figure 6. Entering the RAID BIOS Console ................................................................................ 15

Figure 7. Adapter Selection Screen ............................................................................................ 16

Figure 8. RAID BIOS Console Main Screen ............................................................................... 17

Figure 9. Configuration Wizard Screen...................................................................................... 18

Figure 10. RAID BIOS Console Confirm Page ........................................................................... 19

Figure 11. RAID BIOS Console Configuration Wizard................................................................ 20

Figure 12. DG Definition Screen ................................................................................................. 21

Figure 13. DG Definition Screen – Selecting Devices ................................................................ 22

Figure 14. DG Definition Screen – Device added ....................................................................... 23

Figure 15. DG Definition Screen – Disk Group 0 Added............................................................. 24

Figure 16. DG Definition Screen – Adding Devices to Device Group 1 ...................................... 25

Figure 17. DG Definition Screen – Disk Group 1 Added............................................................. 26

Figure 18. DG Definition Screen – Adding Devices to Disk Group 2 .......................................... 27

Figure 19. DG Definition Screen – Disk Group 2 Added............................................................. 28

Figure 20. Span Definition Screen – Adding an Array Hole........................................................ 29

Figure 21. Span Definition Screen – Array Hole Added.............................................................. 30

Figure 22. VD Definition Screen – Configuring RAID 1 .............................................................. 31

Figure 23. VD Definition Screen – RAID 1 Configured .............................................................. 32

Figure 24. Span Definition Screen – Adding an Array Hole........................................................ 33

Figure 25. Span Definition Screen – Adding Second Array Hole................................................ 34

Figure 26. Span Definition Screen – Array Holes Added............................................................ 35

Figure 27. VD Definition Screen – Configuring RAID 50 ............................................................ 36

Figure 28. VD Definition Screen – Configuring RAID 50 Write Policy ........................................ 37

Figure 29. VD Definition Screen – Configuring RAID 50 Size .................................................... 38

Figure 30. VD Definition Screen – RAID 50 Configured ............................................................. 39

Figure 31. Configuration Wizard Preview Screen ....................................................................... 40

Figure 32. RAID BIOS Console Confirmation Page – Save Configuration ................................. 41

Page 5: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper List of Figures

Revision 1.0 v

Figure 33. RAID BIOS Console Confirmation Page – Initialization............................................. 42

Figure 34. RAID BIOS Console Virtual Disks Screen ................................................................. 43

Figure 35. RAID BIOS Console Virtual Configuration Screen .................................................... 44

Figure 36. RAID BIOS Console Virtual Configuration Screen – Selecting UNCONF Hard Drives45

Figure 37. RAID BIOS Console Physical Drive Screen – Making Global HSP........................... 46

Figure 38. RAID BIOS Console Physical Drive Screen – Global HSP Configured..................... 47

Page 6: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

List of Tables DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper

Revision 1.0

vi

List of Tables

Table 1. Hardware Components ................................................................................................... 2

Table 2. Chenbro* RM31616 Chassis Features ........................................................................... 3

Table 3. Major Board Components ............................................................................................... 6

Table 4. Front Panel SSI Standard 24-pin Connector Pin-out (J1E4) .......................................... 7

Table 5. Connection between Chassis and Server Board ............................................................ 8

Table 6. Backplane SGPIO Function Setting................................................................................ 9

Table 7. RAID Level Selection .................................................................................................... 12

Table 8. RAID Settings ............................................................................................................... 14

Page 7: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper Welcome

Revision 1.0 1

1. Welcome

RAID (Redundant Array of Independent Disks) technology is commonly implemented in server usage models as an option to provide additional data protection. RAID solutions are now also found in other computer environments such as desktops, workstations, and external storage devices that support a large number of hard drives.

This guide provides detailed information on how to set up a storage hardware system using Intel® Server Boards and Intel® RAID controllers on Chenbro* RM31616 Chassis, including information on how to install an Intel® RAID controller in a Chenbro* RM31616 chassis in conjunction with an Intel® Server Board S50000XVN. The guide also provides information on how to attach cables for LED functionality and how to tune RAID subsystem performance for different storage applications. The document will not recommend or endorse any specific Operating System or Storage Application, but is intended to demonstrate how to integrate and configure the hardware in preparation for a storage application usage model.

Page 8: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

Hardware Components DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper

Revision 1.0 2

2. Hardware Components

Table 1. Hardware Components

Quantity Item Manufacturer Model 1 Intel® Server Board Intel S5000XVN

1 Chenbro* Chassis Chenbro RM31616

4 GB Memory Any supported memory

Please refer to the Tested Memory List at http://support.intel.com/support/motherboards/server/s5000psl/sb/CS-022924.htm

2 Intel® Xeon®

processors Intel Please refer to the Supported Processor List at

http://support.intel.com/support/motherboards/server/sb/CS-022346.htm

16 SATA 3.5-inch hard drives

Hitachi HUA721010KLA330

Page 9: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper Chenbro* RM31616 Chassis Introduction

Revision 1.0 3

3. Chenbro* RM31616 Chassis Introduction

For additional details on the Chenbro* RM31616 Chassis, visit http://www.chenbro.com.

Table 2. Chenbro* RM31616 Chassis Features

Design Standard EIA-RS310D

Sheet Metal Material SGCC

Sheet Metal Thickness 1.2 mm

Generality

Plastic Material Type ABS-HB

Mother Board Support Form Factor Extended ATX – 12 x 13 (inches) CEB – 12 x 10.5 (inches) ATX – 12 x 9.6 (inches)

mm (D x W x H) 660 x 432 x 132 (mm) Dimensions

inch (D x W x H) 26 x 17 x 5.2 (inches)

Drive Bay (Internal 2.5-inch) 2

Drive Bay (Internal 3.5-inch) 1

Hot-swap HDD Trays 16

Slim CD-ROM 1

Drive Bays

Slim FDD 1

PSU Form Redundant PSU Support

Maximum Wattage 1000 W

Switch/Controls Power On/Off System Reset Alarm Mute USB 2.0 (x2)

Front Panel

Indicators Power Status LED (x1) HDD Activity LED (x1) LAN Activity LED (x2) FAN Failure and Overheat Warning (x1)

Rear Window Standard Expansion Slots & Rear Window

Slot Opening 7

Security Lock N/A Security

System Security Intrusion Switch

Middle 4x 80-mm (T=38 mm) hot-swap middle fans System Cooling Fans

Rear Optional : 2x 80-mm (T=25 mm) rear fans

Backplanes Backplane (Model Number: 84H331610-009)

16-port Mini SAS Backplane with Mounting Bracket

Cable Cable (Model Number: 26H113215-028) Mini SAS 36pin-to-Mini SAS 36pin (Host) (350 mm)

Page 10: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

Chenbro* RM31616 Chassis Introduction DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper

Revision 1.0 4

Cubic Feet 5.22

Net Weight (Kgs) 15.1

Container Information (20') 188 (Single Packing)

Container Information (40') 406 (Single Packing)

Shipping Info

Container Information (40'HQ) 455 (Single Packing)

Figure 1. Chenbro* RM31616 Chassis

Page 11: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper Set up the Storage Hardware System

Revision 1.0 5

4. Set up the Storage Hardware System

For additional details on the Intel® Server Board and Intel® RAID Controller, visit http://support.intel.com.

4.1 Server Board Connector and Component Layout The following figure shows the board layout of the Server board. Each connector and major component is identified by a letter. A description for each component is provided in the following table.

AF000499

O

KL

M

N

S

P

QR

LL

NN

OOPP

QQRR

KKJJII

HHGG

FFEE

A B EDC I

VAACC

DD ZBBY

XW U

T

F JH

MM

G

Figure 2. Intel® Workstation Board S5000XVN Layout

Page 12: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

Set up the Storage Hardware System DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper

Revision 1.0 6

Table 3. Major Board Components

Description Description A PCI-X 64-bit, 100-MHz full-length / full-height

slot 1 W System fan 2 header

B PCI-X 64-bit, 133-/100-MHz full-length / full-height slot 2

X System fan 1 header

C PCI Express* x4[1] or PCI express* x8[2] slot 3 (x8 physical connector)

Y Processor power connector

D PCI Express* x4 half-length / full-height slot 4 (x8 physical connector)

Z USB header

E CMOS battery AA IDE connector

F PCI Express* x16 full-length / full-height slot 6 (x16 physical connector)

BB Enclosure management SATA SGPIO header[2]

G CD-ROM line-in connector CC Intel® Local Control Panel header

H P12V4 connector DD Hot-swap backplane B header

I Back panel I/O ports EE Enclosure management SAS SES I2C[1]

J Diagnostic and Identify LEDs FF Hot-swap backplane A header

K System fan 6 header GG SATA 0

L System fan 5 header HH SATA 1

M Main power connector II SATA 2 or SAS 0 [3]

N Auxilliary power signal connector JJ SATA 3 or SAS 1 [3]

O DIMM sockets KK SATA 4 or SAS 2 [3]

P Processor 1 socket LL SATA 5 or SAS 3[3]

Q Processor 2 socket MM USB port

R Processor 2 fan header NN Front control panel header

S Processor 1 fan header OO SATA Software RAID 5 key connector[2]

T System fan 4 header PP SAS Software RAID 5 key connector [1]

U System fan 3 header QQ Serial B / emergency management port header

V IPMB connector RR Chassis intrusion header

Note 1: Avaiable with product codes S5000XVNSAS/S5000XVNSASR or BB5000XVNSAS/BB5000XVNSASR.

Note 2: Available with product codes S5000XVNSATA/S5000XVNSATAR or BB5000XVNSATA/BB5000XVNSATAR.

Note 3: SAS connector available with product codes S5000XVNSAS/S5000XVNSASR or BB5000XVNSAS/BB5000XVNSASR.

Page 13: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper Set up the Storage Hardware System

Revision 1.0 7

4.2 Board Front Panel Connector The board provides a 24-pin SSI front panel connector (J1E4) for use with Intel® and third-party chassis. The following table provides the pin-out for this connector.

Table 4. Front Panel SSI Standard 24-pin Connector Pin-out (J1E4)

Pin Signal Name Description Pin Signal Name Description

1 P3V3_STBY (Power_LED_Anode)

Power LED + 2 P3V3_STBY Front Panel Power

3 Key No Connection

4 P5V_STBY (ID LED Anode) ID LED +

5 FP_PWR_LED_N Power LED - 6 FP_ID_LED_BUF_N ID LED -

7 P3V3 (HDD_ACTIVITY_Anode)

HDD Activity LED +

8 FP_LED_STATUS_GREEN_N Status LED Green -

9 LED_HDD_ACTIVITY_N HDD Activity LED -

10 FP_LED_STATUS_AMBER_N Status LED Amber -

11 FP_PWR_BTN_N Power Button

12 NIC1_ACT_LED_N NIC 1 Activity LED -

13 GND (Power Button GND) Power Button Ground

14 NIC1_LINK_LED_N NIC 1 Link LED -

15 BMC_RST_BTN_N Reset Button 16 SMB_SENSOR_3V3STB_DATA SMB Sensor DATA

17 BND (Reset GND) Reset Button Ground

18 SMB_SENSOR_3V3STB_CLK SMB Sensor Clock

19 FP_ID_BTN_N ID Button 20 FP_CHASSIS_INTRU Chassis Intrusion

21 FM_SIO_TEMP_SENSOR Front Panel Temperature Sensor

22 NIC2_ACT_LED_N NIC 2 Activity LED -

23 FP_NMI_BTN_N NMI Button 24 NIC2_LINK_LED_N NIC 2 Link LED -

Note: The Front Panel Connector is identified by “NN” in Figure 2.

Page 14: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

Set up the Storage Hardware System DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper

Revision 1.0 8

4.3 Connection between Chassis and Server Board The connections from a Chenbro* chassis to the board are listed in the following table. The letters under the server board column correspond to the letters identified in Figure 2 for the server board and the pin numbers correspond to those defined in Table 4.

Table 5. Connection between Chassis and Server Board

Chassis Server Board Pin # (If needed)

Main power connector M

P12V4 connector H

Processor power connector Y

System FAN 1 X

System FAN 2 W

System FAN 3 U

System FAN 4 T

Front USB connector Z

Chassis intrusion connector RR

Power LED NN 1,5

HDD LED NN 7,9

Power SW NN 11,13

RESET NN 15,17

LAN 1 NN 12,14

Fron

t Pa

nel C

onne

ctio

n

LAN 2 NN 22,24

4.4 RAID Controller Installation To install the RAID controller, follow these steps:

1. Power off the computer, all drives, enclosures, and system components. Remove the power cord from the computer.

2. Remove the chassis cover and access the PCI Express* add-in card slots. See your server chassis documentation for instructions.

3. Align the controller’s connector with a x8 or x16 PCI Express* slot on the server board.

4. Press down gently but firmly to ensure that the card is properly seated in the slot, as shown in Figure 3. Secure the bracket to the computer chassis.

Page 15: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper Set up the Storage Hardware System

Revision 1.0 9

Figure 3. Inserting the Intel® RAID Controller SRCSASPH16I into a PCI Express* Slot

4.5 Backplane Setup and Cable Connection The 16-port mini SAS Backplane with mounting bracket in the Chenbro* Chassis provides the SGPIO function support, which can be used to indicate HDD failure via a fault LED. SGPIO support is enabled on the backplane via two switches (See Figure 4)

Figure 4. Switches on the Backplane with Default Setting

The following table summarizes how to enable the SGPIO function support for the backplane.

Table 6. Backplane SGPIO Function Setting

SW-1 SW-2 SGPIO Function Setting On On Enable HDD failure and access signal via SGPIO

On Off Enable HDD access signal via SGPIO

Off On Enable HDD failure signal via SGPIO

Off Off Disable HDD failure and access signal via SGPIO

Page 16: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

Set up the Storage Hardware System DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper

Revision 1.0 10

Intel® RAID Controller SRCSASPH16I provides SGPIO support through the sideband of the SFF-8087 Mini-SAS 36-pin cable by default. To get failure and access LED support, the SW-1 and SW-2 on the backplane must be turned on.

1. Turn on SW-1 and SW-2 on the backplane to enable SGPIO function support

2. Connect the “Mini-SAS 36-pin SFF-8087 to SFF-8087” cables to the adapter mini-SAS connectors. Make sure the controller and cables are properly attached.

3. Connect other side of the cables into the backplane shipped with the chassis, as shown in Figure 5.

Figure 5. Backplane Wiring Illustration

4.6 Using Enterprise-class Drives Enterprise-class hard drives should always be used on an enterprise-class system. Use of a desktop-class drive is not recommended due to I/O timeout incompatibilities, lower tolerances for vibration, and a lack of end-to-end data error detection and correction.

Hard drive manufacturers develop drives to meet specific customer requirements for reliability, capacity, performance, and power consumption. Using drives in the application for which they were designed ensures your data is available when and how you need it. Using drives outside of their intended application can negatively impact server productivity.

Page 17: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper Set up the Storage Hardware System

Revision 1.0 11

To get the best performance and avoid drive failures for this storage solution, Intel recommends using enterprise drives designed for 24 X 7 operation with a high workload. Please work with your drive vendor to source Enterprise Class SAS or SATA hard drives.

Note: SAS and SATA drives should not be mixed in the same enclosure. For information on selecting drives, refer to the Enterprise-class versus Desktop-class Hard Drives White Paper available at http://support.intel.com/support/motherboards/server/.

Page 18: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

Setup Array using an Intel® RAID Controller DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper

Revision 1.0 12

5. Setup Array using an Intel® RAID Controller

Intel is committed to providing customers with stable, high-performance, and highly reliable RAID products. However, to optimize RAID performance for a specific application, customers must understand the key factors that can affect the performance of the RAID subsystem and the relationship between the target application and those key factors so that the array can be setup accordingly during system configuration.

The following sections introduce the key factors and then provide a demo for setting up a server for a surveillance application.

5.1 Basic Introduction of RAID Setting for Performance Optimizing Optimizing the overall performance of a RAID subsystem requires careful consideration of several factors that can affect performance, including the controller and disk drive cache settings and the interaction of these settings with system applications. The following sections provide a limited discussion of some of these factors. For a full review of performance tuning, refer to the Intel® RAID Controller Performance Optimization White Paper available at http://support.intel.com/support/motherboards/server/ .

Note: There are a variety of factors that can affect the performance of the RAID subsystem including PCI bus bandwidth, logical drive cache settings, stripe size, hard disk drive cache settings, RAID level, ratio of read versus write operations, ratio of sequential versus random operations, and the number of disks in an array.

5.1.1 RAID Level The Intel® RAID controller SRCSASPH16I supports RAID levels 0, 1, 5, 6, 10, 50, and 60. To ensure the best performance, the optimal RAID level should be selected when the system drive is created. The optimal RAID level for a disk array depends on a number of factors:

The number of physical drives in the disk array

The capacity of the physical drives in the array

The need for data redundancy

The disk performance requirements

The following table provides a quick reference for RAID level selection. This information is simplified and may not be accurate with some applications or tests.

Table 7. RAID Level Selection

Application Remarks Recommendation Operating System Installation the operation system only. R1

Application Server Users access application from the server, but store data in the local system R0 or R5

Developer Server Users transfer data from the server to the local system, edit, and return it to the server R5 or R6

Page 19: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper Setup Array using an Intel® RAID Controller

Revision 1.0 13

Application Remarks Recommendation Mail Server Users log on to the server and transfer data to/from the server

R5 or R6

Transaction Server Hospital/Bank: Users randomly access data for creating new files and updating exisitng files. R5 or R6

Video Server Users transfer large block of sequential data from the server, edit the data, and return the data to the server

R5

Web Server Users log on to the server and view information, enter data, FTP, etc.

R5

5.1.2 Stripe Size For I/O intensive or small block random database access, striping the hard disks in the array with stripes larger than a single record, so that a record falls entirely within one or two stripes, will optimize performance. For data intensive environments or large block sequential access systems that access large records, small stripes (512-byte) cause each record to span across all the hard disks in the array. With each disk storing a portion of the data from the record, accesses are faster because the data transfer interleaves onto multiple disks. However, small stripes rule out multiple overlapped data operations because each access will typically involve all disks.

Small stripes require synchronized spindle disks to prevent degraded performance when accessing short records. Without synchronized spindles, each disk in the array may be at a different rotational position from when their data was written. Completing a disk access requires waiting until each disk has accessed its portion of the record, which can take an extra rotation of the disk platter on one or more disks. Greater the number of disks in the array, longer is the average access time for the array. Synchronized spindles ensure that every disk in the array reaches its data during the same rotation of their respective platters. The access time of the array becomes equal to the average access time of a single disk instead of approaching the product of access time and the number of disks in the array.

Choose the stripe size relative to both the I/O segment size and the number of hard disks in the array, so that most I/O operations either:

Cross many stripes and involve all hard disks in the array.

Or

Do not cross stripes and involve only one hard disk.

5.1.3 Tuning Controller Cache Options Tuning cache memory options on the RAID controller can improve performance. There are three settings available in the controller cache to allow fine tuning:

Read Policy

Write Policy

I/O Policy

Page 20: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

Setup Array using an Intel® RAID Controller DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper

Revision 1.0 14

The following table provides a quick reference for RAID settings. This information is simplified and may not be accurate with some applications or tests. For detailed performance tuning information, refer to the Intel® RAID Controller Performance Optimization White Paper available at http://support.intel.com/support/motherboards/server/.

Table 8. RAID Settings

I/O Policy Direct I/O

Read Policy Adaptive Read Ahead

Write Policy Write Back*

* A RAID controller battery should be used whenever virtual drive write-back cache is enabled and data is mission critical.

5.1.4 Hard Disk Cache Disk drive cache can be enabled in the Virtual Drive Properties page of the RAID configuration utility. There is a risk of data loss using a hard drive cache; an overview is provided below.

Hard disk drive cache is located within the logic of the hard drive. Cache provides enhanced performance for sequential read access by retrieving adjacent data on the drive into the data buffer in case the host computer requests it. This process allows the data to be directly transferred from the drive’s memory when it is requested rather than waiting for a disk access, which results in lower latency. Enabling the hard drive cache can also improve write performance by providing additional memory space for queued data. Write data can be queued in the disk cache and reported as written even though the data will not move from memory to the disk until disk access is available. This reduces the delay during disk I/O operations.

There is an inherent risk in holding data in the drive cache when a write has been acknowledged as complete but is not written to the disk. If the drive loses power, the data in the cache is lost before it is written to the disk. This can cause a “hole” in a data file, which makes the file unusable. Using a UPS mitigates this risk but does not eliminate it.

Note: A soft or hard reset (<Ctrl> + <Alt> + <Del> or the reset button) does not affect the completion of a disk write operation because the disk cache is flushed as long as drive power is maintained.

5.2 RAID Configration Demo for Applications To set up a surveillance server, make sure that your storage system can provide large capacity for video data storage, and with optimized performance. To keep the video safe, store the application data (video data) separate from the operating system so that the application data is not impacted in case the operating system needs to be reinstalled.

To meet this requirement, create RAID 1 using 2 HDDs to only install the operation system without the application data. Then, create RAID 50 using 12 HDDs to create a large capacity for data storage to contain the surveillance application and data. The remaining hard drives can be used as online hot spares to help recover a failed drive utilizing the auto rebuild feature of the RAID controller.

Page 21: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper Setup Array using an Intel® RAID Controller

Revision 1.0 15

The following steps provide detailed instructions for setting up the arrays in the RAID BIOS console with the detailed array settings for optimizing performance:

1. When the host computer is booting, when prompted, hold down the <Ctrl> key and press the <G> key when the text ‘Press <Ctrl><G> to enter the RAID BIOS Console’ appears on the screen (see Figure 6).

Figure 6. Entering the RAID BIOS Console

Page 22: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

Setup Array using an Intel® RAID Controller DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper

Revision 1.0 16

The RAID BIOS Console starts after POST completes and the Adapter Selection screen appears as displayed in figure 7.

Figure 7. Adapter Selection Screen

2. If the system has multiple RAID controllers, select a controller, and click Start to continue. If the system has only one RAID controller, just click Start to continue.

Page 23: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper Setup Array using an Intel® RAID Controller

Revision 1.0 17

The main screen of the RAID BIOS console appears (see Figure 8).

Figure 8. RAID BIOS Console Main Screen

3. Click Configuration Wizard to start the RAID Configuration Wizard for creating the RAID

array.

Page 24: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

Setup Array using an Intel® RAID Controller DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper

Revision 1.0 18

The Configuration Wizard screen appears (see Figure 9).

Figure 9. Configuration Wizard Screen

4. Select New Configuration and click Next.

Page 25: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper Setup Array using an Intel® RAID Controller

Revision 1.0 19

A dialog box appears to warn you that data will be lost (see Figure 10).

5. Click Yes to continue.

Figure 10. RAID BIOS Console Confirm Page

Page 26: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

Setup Array using an Intel® RAID Controller DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper

Revision 1.0 20

6. On the next screen that appears (see Figure 11), select Custom Configuration and

click Next to continue.

Figure 11. RAID BIOS Console Configuration Wizard

Page 27: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper Setup Array using an Intel® RAID Controller

Revision 1.0 21

7. On the DG Definition screen (see Figure 12), first select any two hard drives to make RAID 1.

Figure 12. DG Definition Screen

Page 28: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

Setup Array using an Intel® RAID Controller DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper

Revision 1.0 22

8. Hold down the <Ctrl> key and using the mouse to click on two unconfigured good hard

drives in the Physical Drives panel on the left (see Figure 13), and click AddtoArray to move the drives to a proposed drive group configuration in the Disk Groups panel on the right (see Figure 14).

Figure 13. DG Definition Screen – Selecting Devices

Page 29: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper Setup Array using an Intel® RAID Controller

Revision 1.0 23

Figure 14. DG Definition Screen – Device added

Page 30: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

Setup Array using an Intel® RAID Controller DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper

Revision 1.0 24

9. Click Accept DG.

Figure 15. DG Definition Screen – Disk Group 0 Added

Page 31: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper Setup Array using an Intel® RAID Controller

Revision 1.0 25

10. Hold down the <Ctrl> key while you select six unconfigured good hard drives in the Physical Drives panel on the left, and click AddtoArray to move the drives to a proposed drive group configuration in the Disk Groups panel on the right (see Figure 16).

Figure 16. DG Definition Screen – Adding Devices to Device Group 1

Page 32: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

Setup Array using an Intel® RAID Controller DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper

Revision 1.0 26

11. Click Accept DG to accept the changes.

Figure 17. DG Definition Screen – Disk Group 1 Added

Page 33: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper Setup Array using an Intel® RAID Controller

Revision 1.0 27

12. Hold down the <Ctrl> key while you select the next six unconfigured good hard drives in

the Physical Drives panel on the left, and then click AddtoArray to move the drives to a proposed drive group configuration in the Disk Groups panel on the right (see Figure 18).

Figure 18. DG Definition Screen – Adding Devices to Disk Group 2

Page 34: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

Setup Array using an Intel® RAID Controller DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper

Revision 1.0 28

13. Click Accept DG to accept the changes.

Figure 19. DG Definition Screen – Disk Group 2 Added

Page 35: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper Setup Array using an Intel® RAID Controller

Revision 1.0 29

14. Click Next to continue.

15. On the Span Definition screen (see Figure 20), select DG:0,Hole:0,R0,R1,952720MB, and click Add to SPAN.

Figure 20. Span Definition Screen – Adding an Array Hole

Page 36: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

Setup Array using an Intel® RAID Controller DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper

Revision 1.0 30

16. Click Next.

Figure 21. Span Definition Screen – Array Hole Added

Page 37: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper Setup Array using an Intel® RAID Controller

Revision 1.0 31

17. On the VD Definition screen (see Figure 22), select WBack for the Write Policy and click

Accept to finish RAID1 configuration.

Figure 22. VD Definition Screen – Configuring RAID 1

Page 38: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

Setup Array using an Intel® RAID Controller DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper

Revision 1.0 32

18. On the next screen (see Figure 23), click Back to start RAID50 configuration.

Figure 23. VD Definition Screen – RAID 1 Configured

Page 39: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper Setup Array using an Intel® RAID Controller

Revision 1.0 33

19. On the Span Definition screen (see Figure 24), select DG:1,Hole:0,R0,R5,R6,952720M

and click Add to SPAN.

Figure 24. Span Definition Screen – Adding an Array Hole

Page 40: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

Setup Array using an Intel® RAID Controller DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper

Revision 1.0 34

20. Then, select DG:2,Hole:0,R0,R5,R6,952720M and click Add to SPAN.

Figure 25. Span Definition Screen – Adding Second Array Hole

Page 41: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper Setup Array using an Intel® RAID Controller

Revision 1.0 35

21. Click Next to continue.

Figure 26. Span Definition Screen – Array Holes Added

Page 42: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

Setup Array using an Intel® RAID Controller DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper

Revision 1.0 36

22. On the VD Definition screen, select RAID50 for the RAID Level (see Figure 27), and

select 512 KB for Strip Size, WBack for the Write Policy (see Figure 28), and modify the Select Size value to 9527200 MB (see Figure 29).

Figure 27. VD Definition Screen – Configuring RAID 50

Page 43: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper Setup Array using an Intel® RAID Controller

Revision 1.0 37

Figure 28. VD Definition Screen – Configuring RAID 50 Write Policy

Page 44: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

Setup Array using an Intel® RAID Controller DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper

Revision 1.0 38

Figure 29. VD Definition Screen – Configuring RAID 50 Size

23. Click Accept to finish a RAID 50 configuration.

Page 45: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper Setup Array using an Intel® RAID Controller

Revision 1.0 39

24. On the next screen, click Next to continue.

Figure 30. VD Definition Screen – RAID 50 Configured

Page 46: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

Setup Array using an Intel® RAID Controller DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper

Revision 1.0 40

25. On the next screen (see Figure 31), click Accept to save this RAID configuration.

Figure 31. Configuration Wizard Preview Screen

Page 47: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper Setup Array using an Intel® RAID Controller

Revision 1.0 41

26. On the next screen (see Figure 32), click Yes in the warning dialog that appears to save this configuration.

Figure 32. RAID BIOS Console Confirmation Page – Save Configuration

Page 48: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

Setup Array using an Intel® RAID Controller DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper

Revision 1.0 42

27. On the next screen (see Figure 33), click Yes in the warning dialog that appears to

initialize.

Figure 33. RAID BIOS Console Confirmation Page – Initialization

Page 49: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper Setup Array using an Intel® RAID Controller

Revision 1.0 43

28. Wait until the initialization completes (see Figure 34), and Click Home.

Figure 34. RAID BIOS Console Virtual Disks Screen

Page 50: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

Setup Array using an Intel® RAID Controller DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper

Revision 1.0 44

29. Confirm the RAID1 and RAID50 configuration on the next screen (see Figure 35).

Figure 35. RAID BIOS Console Virtual Configuration Screen

Page 51: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper Setup Array using an Intel® RAID Controller

Revision 1.0 45

30. Click any one of the two remaining UNCONF hard drives in the Physical Drives section

(see Figure 36).

Figure 36. RAID BIOS Console Virtual Configuration Screen – Selecting UNCONF Hard Drives

Page 52: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

Setup Array using an Intel® RAID Controller DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper

Revision 1.0 46

31. On the next screen (see Figure 37), select Make Global HSP and click Go to continue.

Figure 37. RAID BIOS Console Physical Drive Screen – Making Global HSP

Page 53: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper Setup Array using an Intel® RAID Controller

Revision 1.0 47

32. On the next screen (see Figure 38), confirm that you made a global hot spare for your

RAID configuration.

Figure 38. RAID BIOS Console Physical Drive Screen – Global HSP Configured

33. Use the remaining UNCONF hard drive to make another Global hot spare by repeating

steps 30 through 32. The system is now ready for Operating System and application installation. Intel recommends installing the RAID Web Console 2 Utility to provide online management of your raid configuration as well as to monitor RAID health. This application is available for Windows and Linux based operating systems.

Page 54: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

Advanced Data Integrity Protection DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper

Revision 1.0 48

6. Advanced Data Integrity Protection

6.1 Using a RAID Controller Battery A RAID controller battery should be used whenever virtual drive write-back cache is enabled and data is mission critical.

Cache-to-cache I/O is much faster than any other type of I/O operation occurring on the data bus. It is faster to write data to the RAID adapter’s cache memory than it is to write it directly to a storage device because the time required to spin target data under a read or write head is longer than the time required to perform the read or write to a memory device.

If the RAID Controller’s write-back cache option is enabled, data is first written to the cache memory and the write is acknowledged, and then the RAID controller writes the cached data to the storage device when it is available to service the I/O request. However, this method of writing data first to cache memory, acknowledging the write as complete, and then completing the write when the drive is available carries inherent risk. Cached data on the RAID controller can be lost if the AC power fails before the cached data is written to the storage device. The Smart Battery mitigates this risk by providing battery power to the RAID controller memory and holding the data in the RAID cache memory until power is restored. The battery can hold data in the RAID controller’s memory for up to 72 hours.

The Smart Battery accomplishes all of this by monitoring the voltage level of the DRAM modules on the RAID controller. If the voltage drops below a defined level, the Smart Battery switches the memory power source from the RAID controller to the battery pack. The battery pack provides power for the memory until the voltage returns to an acceptable level, at which time the Smart Battery circuit board switches the power source back to the RAID controller. Cached data is then written to the storage device just as though the power loss never occurred. The Smart Battery provides additional fault tolerance even when used with a UPS, which does not prevent a system power supply failure or other system internal power failure.

6.2 Using a UPS for Power Loss Protection An uninterruptible power supply (UPS) is a battery-based system power supply that helps to protect electronic equipment from an unexpected loss of power.

There is no way to provide a battery backup of data that is temporarily stored in the hard disk cache but has not been written to disk. A power outage can corrupt the data on a server or make data unavailable to users. A UPS can reduce the chance of a power outage corrupting the data on a server. Although the addition of UPS is not a guarantee that data is not lost, it does add additional security.

A UPS is highly recommended to protect data in mission-critical configurations. Computers and accessories can suffer damage during a power outage or experience a loss of data that is in transit during the power outage.

Page 55: Intel RAID Controller - DIY Storage System v1.0€¦ · DG Definition Screen – Device added.....23 Figure 15. DG Definition Screen – Disk Group 0 Added.....24 Figure 16. DG Definition

DIY Storage System Guidance Using Intel® Server RAID Controllers Deployment Practices White Paper Summary

Revision 1.0 49

7. Summary

Intel is committed to providing customers with a stable product that offers both high performance and high reliability. In this document, we provided guidance on how to set up a storage hardware system with enhanced data safety and high performance using Intel® server boards and Intel® RAID controllers in a Chenbro* RM31616 Chassis.


Recommended