IT IS THE RESPONSIBILITY OF THE USER TO COMPLY WITH ALL APPLICABLE
REGULATIONS AND BUILDING CODE REQUIREMENTS CONCERNING THE USE OF
THESE PRODUCTS.
IT IS FURTHER THE RESPONSIBILITY OF THE USER TO RESEARCH AND UNDERSTAND
SAFE METHODS OF USE AND HANDLING OF THESE PRODUCTS.
Quad-Lock Building Systems
7398 - 132nd Street
Surrey, BC V3W 4M7
Canada
DRAWN BY:
DATE DRAWN:
REVISION NO:
SCALE:
SHEET SIZE:
APPROVED BY:
REVISION DATE: DRAWING NO:
R
Building Systems
APPROVED ON:
888.711.5625 - Toll Free
604.590.3111
604.590.8412 - fax
www.quadlock.com
2016-11-29
2016-11-21
G. KUSTERMANN
8.5" x 11" [216mm x 279mm]
NOT TO SCALE
QLU-201
Z. PROSTRAN
YYYY-MM-DD
N/A
Continuous Insulation (c.i.) FLOOR ON TOP OF QUAD-LOCK WALL
TJI'S PERPENDICULAR TO WALL
4" [102mm]
6" [152mm]
8" [203mm]
10" [254mm]
12" [305mm]
14" [356mm]
BLUE TIE =
YELLOW TIE =
GREEN TIE =
RED TIE =
BROWN TIE =
BLACK TIE + XT =
CONCRETE CORE
THICKNESS
TIE NAME
ETC.
QUAD-LOCK R-28 [U-0.21] WALL
NOTE:
FOR PRESCRIPTIVE DESIGN REFER TO PCA-100 OR IRC SECTION R611 OR APPLICABLE BUILDING CODE
FOR SIZING AND OR SPACING OF THE FOLLOWING:
· TENSION TIES (Omitted from this drawing for clarity)
· STRAPPING (Omitted from this drawing for clarity)
· CONT. STEEL PLATE BETWEEN SILL AND RIMBOARD (Omitted from this drawing for clarity)
· SILL PLATE
· ANCHOR BOLTS AND WASHERS
· BLOCKING ETC.
SEE TABLE
3
1
8
" [79mm]3
1
8
" [79mm]
PARGING AS SPECIFIED
MINIMUM 6" EXPOSED ABOVE GRADE
WATER PROOFING AS SPECIFIED
(QUAD-LOCK PEEL&STICK OR EQ.)
BACKFILL
QUAD-LOCK PLASTIC TIE
SPACED AT 12" [305mm] O/C VER & HOR
QUAD-LOCK ULTRA PANEL
3.125" [79mm] THICK EPS
INTERIOR WALL FINISH - GYPSUM WALLBOARD OR EQ.
FASTEN TO QUAD-LOCK TIE FLANGES
SLOPE GRADE AWAY FROM WALL
FURRING FOR CEILING FINISH ATTACHMENT
ENGINEERED I-JOISTS AS SPECIFIED
SUBFLOOR
HORIZONTAL WALL REINFORCEMENT
PLACED ALTERNATELY LEFT AND RIGHT
OF VERTICAL REINFORCEMENT
VERTICAL WALL REINFORCEMENT
REMOVE & REUSE METAL TRACK
ON INTERIOR AT TOP OF WALLS
INTERIOR FINISH
STUDS & INSULATION
BLOCKING AS SPECIFIED
BOTTOM PLATE
SQUASH BLOCKING AS SPECIFIED
MEDIUM DENSITY SPRAY POLYURETHANE FOAM (MDSPF)
P.T. SILL PLATE AS SPECIFIED
WITH ANCHOR BOLTS AND SILL SEALER
QUAD-LOCK WIRE TOP TIES
QUAD-LOCK METAL TRACK
PROVIDES FASTENING SURFACE FOR EXTERIOR FINISH
SIDING FINISH
VERTICAL FURRING STRIPS
VAPOR BARRIER
RIMBOARD AS SPECIFIED
CONTINUOUS INSULATION
SHEATHING
IT IS THE RESPONSIBILITY OF THE USER TO COMPLY WITH ALL APPLICABLE
REGULATIONS AND BUILDING CODE REQUIREMENTS CONCERNING THE USE OF
THESE PRODUCTS.
IT IS FURTHER THE RESPONSIBILITY OF THE USER TO RESEARCH AND UNDERSTAND
SAFE METHODS OF USE AND HANDLING OF THESE PRODUCTS.
Quad-Lock Building Systems
7398 - 132nd Street
Surrey, BC V3W 4M7
Canada
DRAWN BY:
DATE DRAWN:
REVISION NO:
SCALE:
SHEET SIZE:
APPROVED BY:
REVISION DATE: DRAWING NO:
R
Building Systems
APPROVED ON:
888.711.5625 - Toll Free
604.590.3111
604.590.8412 - fax
www.quadlock.com
2016-11-29
2016-11-21
G. KUSTERMANN
8.5" x 11" [216mm x 279mm]
NOT TO SCALE
QLU-202
Z. PROSTRAN
YYYY-MM-DD
N/A
Continuous Insulation (c.i.) FLOOR ON TOP OF QUAD-LOCK WALL
TJI'S PARALLEL TO WALL
4" [102mm]
6" [152mm]
8" [203mm]
10" [254mm]
12" [305mm]
14" [356mm]
BLUE TIE =
YELLOW TIE =
GREEN TIE =
RED TIE =
BROWN TIE =
BLACK TIE + XT =
CONCRETE CORE
THICKNESS
TIE NAME
ETC.
QUAD-LOCK R-28 [U-0.21] WALL
NOTE:
FOR PRESCRIPTIVE DESIGN REFER TO PCA-100 OR IRC SECTION R611 OR APPLICABLE BUILDING CODE
FOR SIZING AND OR SPACING OF THE FOLLOWING:
· TENSION TIES (Omitted from this drawing for clarity)
· STRAPPING (Omitted from this drawing for clarity)
· CONT. STEEL PLATE BETWEEN SILL AND RIMBOARD (Omitted from this drawing for clarity)
· SILL PLATE
· ANCHOR BOLTS AND WASHERS
· BLOCKING ETC.
SEE TABLE
3
1
8
" [79mm]3
1
8
" [79mm]
PARGING AS SPECIFIED
MINIMUM 6" EXPOSED ABOVE GRADE
WATER PROOFING AS SPECIFIED
(QUAD-LOCK PEEL&STICK OR EQ.)
BACKFILL
INTERIOR FINISH
STUDS & INSULATION
BOTTOM PLATE
SLOPE GRADE AWAY FROM WALL
SUBFLOOR
ENGINEERED I-JOISTS AS SPECIFIED
FURRING FOR CEILING FINISH ATTACHMENT
MEDIUM DENSITY SPRAY POLYURETHANE FOAM (MDSPF)
QUAD-LOCK PLASTIC TIE
SPACED AT 12" [305mm] O/C VER & HOR
INTERIOR WALL FINISH - GYPSUM WALLBOARD OR EQ.
FASTEN TO QUAD-LOCK TIE FLANGES
VERTICAL WALL REINFORCEMENT
HORIZONTAL WALL REINFORCEMENT
PLACED ALTERNATELY LEFT AND RIGHT
OF VERTICAL REINFORCEMENT
QUAD-LOCK ULTRA PANEL
3.125" [79mm] THICK EPS
REMOVE & REUSE METAL TRACK
ON INTERIOR AT TOP OF WALLS
SIDING FINISH
VERTICAL FURRING STRIPS
VAPOR BARRIER
RIMBOARD AS SPECIFIED
CONTINUOUS INSULATION
SHEATHING
P.T. SILL PLATE AS SPECIFIED
WITH ANCHOR BOLTS AND SILL SEALER
QUAD-LOCK WIRE TOP TIES
QUAD-LOCK METAL TRACK
PROVIDES FASTENING SURFACE FOR EXTERIOR FINISH
IT IS THE RESPONSIBILITY OF THE USER TO COMPLY WITH ALL APPLICABLE
REGULATIONS AND BUILDING CODE REQUIREMENTS CONCERNING THE USE OF
THESE PRODUCTS.
IT IS FURTHER THE RESPONSIBILITY OF THE USER TO RESEARCH AND UNDERSTAND
SAFE METHODS OF USE AND HANDLING OF THESE PRODUCTS.
Quad-Lock Building Systems
7398 - 132nd Street
Surrey, BC V3W 4M7
Canada
DRAWN BY:
DATE DRAWN:
REVISION NO:
SCALE:
SHEET SIZE:
APPROVED BY:
REVISION DATE: DRAWING NO:
R
Building Systems
APPROVED ON:
888.711.5625 - Toll Free
604.590.3111
604.590.8412 - fax
www.quadlock.com
2016-11-29
2016-11-21
G. KUSTERMANN
8.5" x 11" [216mm x 279mm]
NOT TO SCALE
QLU-203
Z. PROSTRAN
YYYY-MM-DD
N/A
FLOOR ON TOP OF QUAD-LOCK WALL
TJI'S PERPENDICULAR TO WALL
4" [102mm]
6" [152mm]
8" [203mm]
10" [254mm]
12" [305mm]
14" [356mm]
BLUE TIE =
YELLOW TIE =
GREEN TIE =
RED TIE =
BROWN TIE =
BLACK TIE + XT =
CONCRETE CORE
THICKNESS
TIE NAME
ETC.
QUAD-LOCK R-28 [U-0.21] WALL
NOTE:
FOR PRESCRIPTIVE DESIGN REFER TO PCA-100 OR IRC SECTION R611 OR APPLICABLE BUILDING CODE
FOR SIZING AND OR SPACING OF THE FOLLOWING:
· TENSION TIES (Omitted from this drawing for clarity)
· STRAPPING (Omitted from this drawing for clarity)
· CONT. STEEL PLATE BETWEEN SILL AND RIMBOARD (Omitted from this drawing for clarity)
· SILL PLATE
· ANCHOR BOLTS AND WASHERS
· BLOCKING ETC.
SEE TABLE
3
1
8
" [79mm]3
1
8
" [79mm]
PARGING AS SPECIFIED
MINIMUM 6" EXPOSED ABOVE GRADE
WATER PROOFING AS SPECIFIED
(QUAD-LOCK PEEL&STICK OR EQ.)
BACKFILL
QUAD-LOCK PLASTIC TIE
SPACED AT 12" [305mm] O/C VER & HOR
QUAD-LOCK ULTRA PANEL
3.125" [79mm] THICK EPS
INTERIOR WALL FINISH - GYPSUM WALLBOARD OR EQ.
FASTEN TO QUAD-LOCK TIE FLANGES
SLOPE GRADE AWAY FROM WALL
FURRING FOR CEILING FINISH ATTACHMENT
ENGINEERED I-JOISTS AS SPECIFIED
BLOCKING AS SPECIFIED
HORIZONTAL WALL REINFORCEMENT
PLACED ALTERNATELY LEFT AND RIGHT
OF VERTICAL REINFORCEMENT
VERTICAL WALL REINFORCEMENT
REMOVE & REUSE METAL TRACK
ON INTERIOR AT TOP OF WALLS
P.T. SILL PLATE AS SPECIFIED
WITH ANCHOR BOLTS AND SILL SEALER
QUAD-LOCK WIRE TOP TIES
QUAD-LOCK METAL TRACK
PROVIDES FASTENING SURFACE FOR EXTERIOR FINISH
SIDING FINISH
SHEATHING
VERTICAL FURRING STRIPS
VAPOR BARRIER
RIMBOARD AS SPECIFIED
INTERIOR FINISH
STUDS & INSULATION
SUBFLOOR
BOTTOM PLATE
SQUASH BLOCKING AS SPECIFIED
MEDIUM DENSITY SPRAY POLYURETHANE FOAM (MDSPF)
IT IS THE RESPONSIBILITY OF THE USER TO COMPLY WITH ALL APPLICABLE
REGULATIONS AND BUILDING CODE REQUIREMENTS CONCERNING THE USE OF
THESE PRODUCTS.
IT IS FURTHER THE RESPONSIBILITY OF THE USER TO RESEARCH AND UNDERSTAND
SAFE METHODS OF USE AND HANDLING OF THESE PRODUCTS.
Quad-Lock Building Systems
7398 - 132nd Street
Surrey, BC V3W 4M7
Canada
DRAWN BY:
DATE DRAWN:
REVISION NO:
SCALE:
SHEET SIZE:
APPROVED BY:
REVISION DATE: DRAWING NO:
R
Building Systems
APPROVED ON:
888.711.5625 - Toll Free
604.590.3111
604.590.8412 - fax
www.quadlock.com
2016-11-29
2016-11-21
G. KUSTERMANN
8.5" x 11" [216mm x 279mm]
NOT TO SCALE
QLU-204
Z. PROSTRAN
YYYY-MM-DD
N/A
FLOOR ON TOP OF QUAD-LOCK WALL
TJI'S PARALLEL TO WALL
4" [102mm]
6" [152mm]
8" [203mm]
10" [254mm]
12" [305mm]
14" [356mm]
BLUE TIE =
YELLOW TIE =
GREEN TIE =
RED TIE =
BROWN TIE =
BLACK TIE + XT =
CONCRETE CORE
THICKNESS
TIE NAME
ETC.
QUAD-LOCK R-28 [U-0.21] WALL
NOTE:
FOR PRESCRIPTIVE DESIGN REFER TO PCA-100 OR IRC SECTION R611 OR APPLICABLE BUILDING CODE
FOR SIZING AND OR SPACING OF THE FOLLOWING:
· TENSION TIES (Omitted from this drawing for clarity)
· STRAPPING (Omitted from this drawing for clarity)
· CONT. STEEL PLATE BETWEEN SILL AND RIMBOARD (Omitted from this drawing for clarity)
· SILL PLATE
· ANCHOR BOLTS AND WASHERS
· BLOCKING ETC.
SEE TABLE
3
1
8
" [79mm]3
1
8
" [79mm]
WATER PROOFING AS SPECIFIED
(QUAD-LOCK PEEL&STICK OR EQ.)
BACKFILL
INTERIOR FINISH
STUDS & INSULATION
SHEATHING
VERTICAL FURRING STRIPS
SLOPE GRADE AWAY FROM WALL
VAPOR BARRIER
BOTTOM PLATE
MEDIUM DENSITY SPRAY POLYURETHANE FOAM (MDSPF)
SUBFLOOR
FULL DEPTH BLOCKING - 24" [600mm] O/C MAX OR AS SPECIFIED
PARGING AS SPECIFIED
MINIMUM 6" EXPOSED ABOVE GRADE
SIDING FINISH
RIMBOARD AS SPECIFIED
P.T. SILL PLATE AS SPECIFIED
WITH ANCHOR BOLTS AND SILL SEALER
QUAD-LOCK WIRE TOP TIES
QUAD-LOCK METAL TRACK
PROVIDES FASTENING SURFACE FOR EXTERIOR FINISH
ENGINEERED I-JOISTS AS SPECIFIED
FURRING FOR CEILING FINISH ATTACHMENT
QUAD-LOCK PLASTIC TIE
SPACED AT 12" [305mm] O/C VER & HOR
INTERIOR WALL FINISH - GYPSUM WALLBOARD OR EQ.
FASTEN TO QUAD-LOCK TIE FLANGES
VERTICAL WALL REINFORCEMENT
HORIZONTAL WALL REINFORCEMENT
PLACED ALTERNATELY LEFT AND RIGHT
OF VERTICAL REINFORCEMENT
QUAD-LOCK ULTRA PANEL
3.125" [79mm] THICK EPS
REMOVE & REUSE METAL TRACK
ON INTERIOR AT TOP OF WALLS
IT IS THE RESPONSIBILITY OF THE USER TO COMPLY WITH ALL APPLICABLE
REGULATIONS AND BUILDING CODE REQUIREMENTS CONCERNING THE USE OF
THESE PRODUCTS.
IT IS FURTHER THE RESPONSIBILITY OF THE USER TO RESEARCH AND UNDERSTAND
SAFE METHODS OF USE AND HANDLING OF THESE PRODUCTS.
Quad-Lock Building Systems
7398 - 132nd Street
Surrey, BC V3W 4M7
Canada
DRAWN BY:
DATE DRAWN:
REVISION NO:
SCALE:
SHEET SIZE:
APPROVED BY:
REVISION DATE: DRAWING NO:
R
Building Systems
APPROVED ON:
888.711.5625 - Toll Free
604.590.3111
604.590.8412 - fax
www.quadlock.com
2016-11-29
2016-11-21
G. KUSTERMANN
8.5" x 11" [216mm x 279mm]
NOT TO SCALE
QLU-205
Z. PROSTRAN
YYYY-MM-DD
N/A
FLOOR ON TOP OF QUAD-LOCK WALL
WOOD JOISTS PERPENDICULAR TO WALL
4" [102mm]
6" [152mm]
8" [203mm]
10" [254mm]
12" [305mm]
14" [356mm]
BLUE TIE =
YELLOW TIE =
GREEN TIE =
RED TIE =
BROWN TIE =
BLACK TIE + XT =
CONCRETE CORE
THICKNESS
TIE NAME
ETC.
QUAD-LOCK R-28 [U-0.21] WALL
NOTE:
FOR PRESCRIPTIVE DESIGN REFER TO PCA-100 OR IRC SECTION R611 OR APPLICABLE BUILDING CODE
FOR SIZING AND OR SPACING OF THE FOLLOWING:
· TENSION TIES (Omitted from this drawing for clarity)
· STRAPPING (Omitted from this drawing for clarity)
· CONT. STEEL PLATE BETWEEN SILL AND RIMBOARD (Omitted from this drawing for clarity)
· SILL PLATE
· ANCHOR BOLTS AND WASHERS
· BLOCKING ETC.
SEE TABLE
3
1
8
" [79mm]3
1
8
" [79mm]
PARGING AS SPECIFIED
MINIMUM 6" EXPOSED ABOVE GRADE
SIDING FINISH
WATER PROOFING AS SPECIFIED
(QUAD-LOCK PEEL&STICK OR EQ.)
BACKFILL
INTERIOR FINISH
STUDS & INSULATION
BOTTOM PLATE
SHEATHING
VERTICAL FURRING STRIPS
SLOPE GRADE AWAY FROM WALL
VAPOR BARRIER
RIMBOARD AS SPECIFIED
FURRING FOR CEILING FINISH ATTACHMENT
WOOD JOISTS AS SPECIFIED
SUBFLOOR
BLOCKING AS SPECIFIED
MEDIUM DENSITY SPRAY POLYURETHANE FOAM (MDSPF)
QUAD-LOCK PLASTIC TIE
SPACED AT 12" [305mm] O/C VER & HOR
INTERIOR WALL FINISH - GYPSUM WALLBOARD OR EQ.
FASTEN TO QUAD-LOCK TIE FLANGES
HORIZONTAL WALL REINFORCEMENT
PLACED ALTERNATELY LEFT AND RIGHT
OF VERTICAL REINFORCEMENT
QUAD-LOCK ULTRA PANEL
3.125" [79mm] THICK EPS
VERTICAL WALL REINFORCEMENT
REMOVE & REUSE METAL TRACK
ON INTERIOR AT TOP OF WALLS
P.T. SILL PLATE AS SPECIFIED
WITH ANCHOR BOLTS AND SILL SEALER
QUAD-LOCK WIRE TOP TIES
QUAD-LOCK METAL TRACK
PROVIDES FASTENING SURFACE FOR EXTERIOR FINISH
IT IS THE RESPONSIBILITY OF THE USER TO COMPLY WITH ALL APPLICABLE
REGULATIONS AND BUILDING CODE REQUIREMENTS CONCERNING THE USE OF
THESE PRODUCTS.
IT IS FURTHER THE RESPONSIBILITY OF THE USER TO RESEARCH AND UNDERSTAND
SAFE METHODS OF USE AND HANDLING OF THESE PRODUCTS.
Quad-Lock Building Systems
7398 - 132nd Street
Surrey, BC V3W 4M7
Canada
DRAWN BY:
DATE DRAWN:
REVISION NO:
SCALE:
SHEET SIZE:
APPROVED BY:
REVISION DATE: DRAWING NO:
R
Building Systems
APPROVED ON:
888.711.5625 - Toll Free
604.590.3111
604.590.8412 - fax
www.quadlock.com
2016-11-29
2016-11-21
G. KUSTERMANN
8.5" x 11" [216mm x 279mm]
NOT TO SCALE
QLU-206
Z. PROSTRAN
YYYY-MM-DD
N/A
FLOOR ON TOP OF QUAD-LOCK WALL
WOOD JOISTS PARALLEL TO WALL
4" [102mm]
6" [152mm]
8" [203mm]
10" [254mm]
12" [305mm]
14" [356mm]
BLUE TIE =
YELLOW TIE =
GREEN TIE =
RED TIE =
BROWN TIE =
BLACK TIE + XT =
CONCRETE CORE
THICKNESS
TIE NAME
ETC.
QUAD-LOCK R-28 [U-0.21] WALL
NOTE:
FOR PRESCRIPTIVE DESIGN REFER TO PCA-100 OR IRC SECTION R611 OR APPLICABLE BUILDING CODE
FOR SIZING AND OR SPACING OF THE FOLLOWING:
· TENSION TIES (Omitted from this drawing for clarity)
· STRAPPING (Omitted from this drawing for clarity)
· CONT. STEEL PLATE BETWEEN SILL AND RIMBOARD (Omitted from this drawing for clarity)
· SILL PLATE
· ANCHOR BOLTS AND WASHERS
· BLOCKING ETC.
SEE TABLE
3
1
8
" [79mm]3
1
8
" [79mm]
PARGING AS SPECIFIED
MINIMUM 6" EXPOSED ABOVE GRADE
SIDING FINISH
WATER PROOFING AS SPECIFIED
(QUAD-LOCK PEEL&STICK OR EQ.)
BACKFILL
INTERIOR FINISH
STUDS & INSULATION
BOTTOM PLATE
RIMBOARD AS SPECIFIED
SHEATHING
VERTICAL FURRING STRIPS
SLOPE GRADE AWAY FROM WALL
VAPOR BARRIER
SUBFLOOR
FURRING FOR CEILING FINISH ATTACHMENT
MEDIUM DENSITY SPRAY POLYURETHANE FOAM (MDSPF)
WOOD JOISTS AS SPECIFIED
QUAD-LOCK PLASTIC TIE
SPACED AT 12" [305mm] O/C VER & HOR
INTERIOR WALL FINISH - GYPSUM WALLBOARD OR EQ.
FASTEN TO QUAD-LOCK TIE FLANGES
HORIZONTAL WALL REINFORCEMENT
PLACED ALTERNATELY LEFT AND RIGHT
OF VERTICAL REINFORCEMENT
QUAD-LOCK ULTRA PANEL
3.125" [79mm] THICK EPS
VERTICAL WALL REINFORCEMENT
FULL DEPTH BLOCKING - 24" [600mm] O/C MAX OR AS SPECIFIED
REMOVE & REUSE METAL TRACK
ON INTERIOR AT TOP OF WALLS
P.T. SILL PLATE AS SPECIFIED
WITH ANCHOR BOLTS AND SILL SEALER
QUAD-LOCK WIRE TOP TIES
QUAD-LOCK METAL TRACK
PROVIDES FASTENING SURFACE FOR EXTERIOR FINISH
IT IS THE RESPONSIBILITY OF THE USER TO COMPLY WITH ALL APPLICABLE
REGULATIONS AND BUILDING CODE REQUIREMENTS CONCERNING THE USE OF
THESE PRODUCTS.
IT IS FURTHER THE RESPONSIBILITY OF THE USER TO RESEARCH AND UNDERSTAND
SAFE METHODS OF USE AND HANDLING OF THESE PRODUCTS.
Quad-Lock Building Systems
7398 - 132nd Street
Surrey, BC V3W 4M7
Canada
DRAWN BY:
DATE DRAWN:
REVISION NO:
SCALE:
SHEET SIZE:
APPROVED BY:
REVISION DATE: DRAWING NO:
R
Building Systems
APPROVED ON:
888.711.5625 - Toll Free
604.590.3111
604.590.8412 - fax
www.quadlock.com
2016-11-29
2016-11-21
G. KUSTERMANN
8.5" x 11" [216mm x 279mm]
NOT TO SCALE
QLU-207
Z. PROSTRAN
YYYY-MM-DD
N/A
FLOOR ON TOP OF QUAD-LOCK WALL
WOOD TRUSSES PERPENDICULAR TO WALL
4" [102mm]
6" [152mm]
8" [203mm]
10" [254mm]
12" [305mm]
14" [356mm]
BLUE TIE =
YELLOW TIE =
GREEN TIE =
RED TIE =
BROWN TIE =
BLACK TIE + XT =
CONCRETE CORE
THICKNESS
TIE NAME
ETC.
QUAD-LOCK R-28 [U-0.21] WALL
NOTE:
FOR PRESCRIPTIVE DESIGN REFER TO PCA-100 OR IRC SECTION R611 OR APPLICABLE BUILDING CODE
FOR SIZING AND OR SPACING OF THE FOLLOWING:
· TENSION TIES (Omitted from this drawing for clarity)
· STRAPPING (Omitted from this drawing for clarity)
· CONT. STEEL PLATE BETWEEN SILL AND RIMBOARD (Omitted from this drawing for clarity)
· SILL PLATE
· ANCHOR BOLTS AND WASHERS
· BLOCKING ETC.
SEE TABLE
3
1
8
" [79mm]3
1
8
" [79mm]
PARGING AS SPECIFIED
MINIMUM 6" EXPOSED ABOVE GRADE
WATER PROOFING AS SPECIFIED
(QUAD-LOCK PEEL&STICK OR EQ.)
BACKFILL
SHEATHING
VERTICAL FURRING STRIPS
SLOPE GRADE AWAY FROM WALL
VAPOR BARRIER
PERIMETER BAND AS SPECIFIED
QUAD-LOCK PLASTIC TIE
SPACED AT 12" [305mm] O/C VER & HOR
INTERIOR WALL FINISH - GYPSUM WALLBOARD OR EQ.
FASTEN TO QUAD-LOCK TIE FLANGES
HORIZONTAL WALL REINFORCEMENT
PLACED ALTERNATELY LEFT AND RIGHT
OF VERTICAL REINFORCEMENT
QUAD-LOCK ULTRA PANEL
3.125" [79mm] THICK EPS
VERTICAL WALL REINFORCEMENT
INTERIOR FINISH
STUDS & INSULATION
BOTTOM PLATE
SUBFLOOR
MEDIUM DENSITY SPRAY POLYURETHANE FOAM (MDSPF)
SIDING FINISH
P.T. SILL PLATE AS SPECIFIED
WITH ANCHOR BOLTS AND SILL SEALER
QUAD-LOCK WIRE TOP TIES
QUAD-LOCK METAL TRACK
PROVIDES FASTENING SURFACE FOR EXTERIOR FINISH
FURRING FOR CEILING FINISH ATTACHMENT
FLOOR TRUSSES AS SPECIFIED
REMOVE & REUSE METAL TRACK
ON INTERIOR AT TOP OF WALLS
IT IS THE RESPONSIBILITY OF THE USER TO COMPLY WITH ALL APPLICABLE
REGULATIONS AND BUILDING CODE REQUIREMENTS CONCERNING THE USE OF
THESE PRODUCTS.
IT IS FURTHER THE RESPONSIBILITY OF THE USER TO RESEARCH AND UNDERSTAND
SAFE METHODS OF USE AND HANDLING OF THESE PRODUCTS.
Quad-Lock Building Systems
7398 - 132nd Street
Surrey, BC V3W 4M7
Canada
DRAWN BY:
DATE DRAWN:
REVISION NO:
SCALE:
SHEET SIZE:
APPROVED BY:
REVISION DATE: DRAWING NO:
R
Building Systems
APPROVED ON:
888.711.5625 - Toll Free
604.590.3111
604.590.8412 - fax
www.quadlock.com
2016-11-29
2016-11-21
G. KUSTERMANN
8.5" x 11" [216mm x 279mm]
NOT TO SCALE
QLU-208
Z. PROSTRAN
YYYY-MM-DD
N/A
FLOOR ON TOP OF QUAD-LOCK WALL
WOOD TRUSSES PARALLEL TO WALL
4" [102mm]
6" [152mm]
8" [203mm]
10" [254mm]
12" [305mm]
14" [356mm]
BLUE TIE =
YELLOW TIE =
GREEN TIE =
RED TIE =
BROWN TIE =
BLACK TIE + XT =
CONCRETE CORE
THICKNESS
TIE NAME
ETC.
QUAD-LOCK R-28 [U-0.21] WALL
NOTE:
FOR PRESCRIPTIVE DESIGN REFER TO PCA-100 OR IRC SECTION R611 OR APPLICABLE BUILDING CODE
FOR SIZING AND OR SPACING OF THE FOLLOWING:
· TENSION TIES (Omitted from this drawing for clarity)
· STRAPPING (Omitted from this drawing for clarity)
· CONT. STEEL PLATE BETWEEN SILL AND RIMBOARD (Omitted from this drawing for clarity)
· SILL PLATE
· ANCHOR BOLTS AND WASHERS
· BLOCKING ETC.
SEE TABLE
3
1
8
" [79mm]3
1
8
" [79mm]
WATER PROOFING AS SPECIFIED
(QUAD-LOCK PEEL&STICK OR EQ.)
BACKFILL
INTERIOR FINISH
STUDS & INSULATION
BOTTOM PLATE
SLOPE GRADE AWAY FROM WALL
SUBFLOOR
FURRING FOR CEILING FINISH ATTACHMENT
LATERAL BRACING (STRONGBACK) AS SPECIFIED
FLOOR TRUSSES AS SPECIFIED
MEDIUM DENSITY SPRAY POLYURETHANE FOAM (MDSPF)
SIDING FINISH
RIMBOARD AS SPECIFIED
SHEATHING
VERTICAL FURRING STRIPS
VAPOR BARRIER
QUAD-LOCK PLASTIC TIE
SPACED AT 12" [305mm] O/C VER & HOR
INTERIOR WALL FINISH - GYPSUM WALLBOARD OR EQ.
FASTEN TO QUAD-LOCK TIE FLANGES
HORIZONTAL WALL REINFORCEMENT
PLACED ALTERNATELY LEFT AND RIGHT
OF VERTICAL REINFORCEMENT
QUAD-LOCK ULTRA PANEL
3.125" [79mm] THICK EPS
VERTICAL WALL REINFORCEMENT
FULL DEPTH BLOCKING - 24" [600mm] O/C MAX OR AS SPECIFIED
REMOVE & REUSE METAL TRACK
ON INTERIOR AT TOP OF WALLS
P.T. SILL PLATE AS SPECIFIED
WITH ANCHOR BOLTS AND SILL SEALER
QUAD-LOCK WIRE TOP TIES
QUAD-LOCK METAL TRACK
PROVIDES FASTENING SURFACE FOR EXTERIOR FINISH
PARGING AS SPECIFIED
MINIMUM 6" EXPOSED ABOVE GRADE
IT IS THE RESPONSIBILITY OF THE USER TO COMPLY WITH ALL APPLICABLE
REGULATIONS AND BUILDING CODE REQUIREMENTS CONCERNING THE USE OF
THESE PRODUCTS.
IT IS FURTHER THE RESPONSIBILITY OF THE USER TO RESEARCH AND UNDERSTAND
SAFE METHODS OF USE AND HANDLING OF THESE PRODUCTS.
Quad-Lock Building Systems
7398 - 132nd Street
Surrey, BC V3W 4M7
Canada
DRAWN BY:
DATE DRAWN:
REVISION NO:
SCALE:
SHEET SIZE:
APPROVED BY:
REVISION DATE: DRAWING NO:
R
Building Systems
APPROVED ON:
888.711.5625 - Toll Free
604.590.3111
604.590.8412 - fax
www.quadlock.com
2016-11-29
2016-11-21
G. KUSTERMANN
8.5" x 11" [216mm x 279mm]
NOT TO SCALE
QLU-209
Z. PROSTRAN
YYYY-MM-DD
N/A
FLOOR AGAINST TOP OF QUAD-LOCK WALL
TJI'S PERPENDICULAR TO WALL
4" [102mm]
6" [152mm]
8" [203mm]
10" [254mm]
12" [305mm]
14" [356mm]
BLUE TIE =
YELLOW TIE =
GREEN TIE =
RED TIE =
BROWN TIE =
BLACK TIE + XT =
CONCRETE CORE
THICKNESS
TIE NAME
ETC.
QUAD-LOCK R-28 [U-0.21] WALL
NOTE:
FOR PRESCRIPTIVE DESIGN REFER TO PCA-100 OR IRC SECTION R611 OR APPLICABLE BUILDING CODE
FOR SIZING AND OR SPACING OF THE FOLLOWING:
· TENSION TIES (Omitted from this drawing for clarity)
· STRAPPING (Omitted from this drawing for clarity)
· CONT. STEEL PLATE BETWEEN SILL AND RIMBOARD (Omitted from this drawing for clarity)
· SILL PLATE
· ANCHOR BOLTS AND WASHERS
· BLOCKING ETC.
SEE TABLE
3
1
8
" [79mm]3
1
8
" [79mm]
PARGING AS SPECIFIED
MINIMUM 6" EXPOSED ABOVE GRADE
WATER PROOFING AS SPECIFIED
(QUAD-LOCK PEEL&STICK OR EQ.)
BACKFILL
INTERIOR FINISH
STUDS & INSULATION
BOTTOM PLATE
SLOPE GRADE AWAY FROM WALL
SUBFLOOR
BLOCKING AS SPECIFIED
CUT OUT HOLES IN EPS PANELS AND FILL IN WITH CONCRETE
AT EVERY BOLT LOCATION
MIN. 7.25" [185mm] DIAMETER FOR ULTRA PANELS
LEDGER BOARD
WITH ANCHOR BOLTS
AS SPECIFIED
ENGINEERED I-JOISTS AS SPECIFIED
FURRING FOR CEILING FINISH ATTACHMENT
SHEATHING
CONTINUOUS INSULATION
VAPOR BARRIER
EXTERIOR FINISH AS SPECIFIED
QUAD-LOCK PLASTIC TIE
SPACED AT 12" [305mm] O/C VER & HOR
INTERIOR WALL FINISH - GYPSUM WALLBOARD OR EQ.
FASTEN TO QUAD-LOCK TIE FLANGES
HORIZONTAL WALL REINFORCEMENT
PLACED ALTERNATELY LEFT AND RIGHT
OF VERTICAL REINFORCEMENT
QUAD-LOCK ULTRA PANEL
3.125" [79mm] THICK EPS
VERTICAL WALL REINFORCEMENT
REMOVE & REUSE METAL TRACK
ON INTERIOR AT TOP OF WALLS
P.T. SILL PLATE AS SPECIFIED
WITH ANCHOR BOLTS AND SILL SEALER
QUAD-LOCK WIRE TOP TIES
QUAD-LOCK METAL TRACK
PROVIDES FASTENING SURFACE FOR EXTERIOR FINISH
IT IS THE RESPONSIBILITY OF THE USER TO COMPLY WITH ALL APPLICABLE
REGULATIONS AND BUILDING CODE REQUIREMENTS CONCERNING THE USE OF
THESE PRODUCTS.
IT IS FURTHER THE RESPONSIBILITY OF THE USER TO RESEARCH AND UNDERSTAND
SAFE METHODS OF USE AND HANDLING OF THESE PRODUCTS.
Quad-Lock Building Systems
7398 - 132nd Street
Surrey, BC V3W 4M7
Canada
DRAWN BY:
DATE DRAWN:
REVISION NO:
SCALE:
SHEET SIZE:
APPROVED BY:
REVISION DATE: DRAWING NO:
R
Building Systems
APPROVED ON:
888.711.5625 - Toll Free
604.590.3111
604.590.8412 - fax
www.quadlock.com
2016-11-29
2016-11-21
G. KUSTERMANN
8.5" x 11" [216mm x 279mm]
NOT TO SCALE
QLU-210
Z. PROSTRAN
YYYY-MM-DD
N/A
FLOOR AGAINST TOP OF QUAD-LOCK WALL
TJI'S PARALLEL TO WALL
4" [102mm]
6" [152mm]
8" [203mm]
10" [254mm]
12" [305mm]
14" [356mm]
BLUE TIE =
YELLOW TIE =
GREEN TIE =
RED TIE =
BROWN TIE =
BLACK TIE + XT =
CONCRETE CORE
THICKNESS
TIE NAME
ETC.
QUAD-LOCK R-28 [U-0.21] WALL
NOTE:
FOR PRESCRIPTIVE DESIGN REFER TO PCA-100 OR IRC SECTION R611 OR APPLICABLE BUILDING CODE
FOR SIZING AND OR SPACING OF THE FOLLOWING:
· TENSION TIES (Omitted from this drawing for clarity)
· STRAPPING (Omitted from this drawing for clarity)
· CONT. STEEL PLATE BETWEEN SILL AND RIMBOARD (Omitted from this drawing for clarity)
· SILL PLATE
· ANCHOR BOLTS AND WASHERS
· BLOCKING ETC.
SEE TABLE
3
1
8
" [79mm]3
1
8
" [79mm]
PARGING AS SPECIFIED
MINIMUM 6" EXPOSED ABOVE GRADE
INTERIOR FINISH
STUDS & INSULATION
BOTTOM PLATE
SHEATHING
EXTERIOR FINISH AS SPECIFIED
P.T. SILL PLATE AS SPECIFIED
WITH ANCHOR BOLTS AND SILL SEALER
VAPOR BARRIER
SUBFLOOR
BLOCKING AS SPECIFIED
ENGINEERED I-JOISTS AS SPECIFIED
FURRING FOR CEILING FINISH ATTACHMENT
WATER PROOFING AS SPECIFIED
(QUAD-LOCK PEEL&STICK OR EQ.)
BACKFILL
SLOPE GRADE AWAY FROM WALL
CUT OUT HOLES IN EPS PANELS AND FILL IN WITH CONCRETE
AT EVERY BOLT LOCATION
MIN. 7.25" [185mm] DIAMETER FOR ULTRA PANELS
LEDGER BOARD WITH ANCHOR BOLTS AS SPECIFIED
QUAD-LOCK PLASTIC TIE
SPACED AT 12" [305mm] O/C VER & HOR
INTERIOR WALL FINISH - GYPSUM WALLBOARD OR EQ.
FASTEN TO QUAD-LOCK TIE FLANGES
HORIZONTAL WALL REINFORCEMENT
PLACED ALTERNATELY LEFT AND RIGHT
OF VERTICAL REINFORCEMENT
QUAD-LOCK ULTRA PANEL
3.125" [79mm] THICK EPS
VERTICAL WALL REINFORCEMENT
TAPER-CUT QUAD-LOCK PANELS
QUAD-LOCK METAL TRACK
FASTENING SURFACE FOR EXTERIOR FINISH
REMOVE & REUSE METAL TRACK
ON INTERIOR AT TOP OF WALLS
QUAD-LOCK WIRE TOP TIES
IT IS THE RESPONSIBILITY OF THE USER TO COMPLY WITH ALL APPLICABLE
REGULATIONS AND BUILDING CODE REQUIREMENTS CONCERNING THE USE OF
THESE PRODUCTS.
IT IS FURTHER THE RESPONSIBILITY OF THE USER TO RESEARCH AND UNDERSTAND
SAFE METHODS OF USE AND HANDLING OF THESE PRODUCTS.
Quad-Lock Building Systems
7398 - 132nd Street
Surrey, BC V3W 4M7
Canada
DRAWN BY:
DATE DRAWN:
REVISION NO:
SCALE:
SHEET SIZE:
APPROVED BY:
REVISION DATE: DRAWING NO:
R
Building Systems
APPROVED ON:
888.711.5625 - Toll Free
604.590.3111
604.590.8412 - fax
www.quadlock.com
2016-11-29
2016-11-21
G. KUSTERMANN
8.5" x 11" [216mm x 279mm]
NOT TO SCALE
QLU-211
Z. PROSTRAN
YYYY-MM-DD
N/A
FLOOR AGAINST TOP OF QUAD-LOCK WALL
WOOD JOISTS PERPENDICULAR TO WALL
4" [102mm]
6" [152mm]
8" [203mm]
10" [254mm]
12" [305mm]
14" [356mm]
BLUE TIE =
YELLOW TIE =
GREEN TIE =
RED TIE =
BROWN TIE =
BLACK TIE + XT =
CONCRETE CORE
THICKNESS
TIE NAME
ETC.
QUAD-LOCK R-28 [U-0.21] WALL
NOTE:
FOR PRESCRIPTIVE DESIGN REFER TO PCA-100 OR IRC SECTION R611 OR APPLICABLE BUILDING CODE
FOR SIZING AND OR SPACING OF THE FOLLOWING:
· TENSION TIES (Omitted from this drawing for clarity)
· STRAPPING (Omitted from this drawing for clarity)
· CONT. STEEL PLATE BETWEEN SILL AND RIMBOARD (Omitted from this drawing for clarity)
· SILL PLATE
· ANCHOR BOLTS AND WASHERS
· BLOCKING ETC.
SEE TABLE
3
1
8
" [79mm]3
1
8
" [79mm]
PARGING AS SPECIFIED
MINIMUM 6" EXPOSED ABOVE GRADE
INTERIOR FINISH
STUDS & INSULATION
BOTTOM PLATE
P.T. SILL PLATE AS SPECIFIED
WITH ANCHOR BOLTS AND SILL SEALER
SUBFLOOR
BLOCKING AS SPECIFIED
LEDGER BOARD WITH ANCHOR BOLTS AS SPECIFIED
WOOD JOISTS AS SPECIFIED
FURRING FOR CEILING FINISH ATTACHMENT
SHEATHING
CONTINUOUS INSULATION
VAPOR BARRIER
EXTERIOR FINISH AS SPECIFIED
WATER PROOFING AS SPECIFIED
(QUAD-LOCK PEEL&STICK OR EQ.)
BACKFILL
SLOPE GRADE AWAY FROM WALL
CUT OUT HOLES IN EPS PANELS AND FILL IN WITH CONCRETE
AT EVERY BOLT LOCATION
MIN. 7.25" [185mm] DIAMETER FOR ULTRA PANELS
QUAD-LOCK PLASTIC TIE
SPACED AT 12" [305mm] O/C VER & HOR
INTERIOR WALL FINISH - GYPSUM WALLBOARD OR EQ.
FASTEN TO QUAD-LOCK TIE FLANGES
HORIZONTAL WALL REINFORCEMENT
PLACED ALTERNATELY LEFT AND RIGHT
OF VERTICAL REINFORCEMENT
QUAD-LOCK ULTRA PANEL
3.125" [79mm] THICK EPS
VERTICAL WALL REINFORCEMENT
REMOVE & REUSE METAL TRACK
ON INTERIOR AT TOP OF WALLS
QUAD-LOCK METAL TRACK
FASTENING SURFACE FOR EXTERIOR FINISH
QUAD-LOCK WIRE TOP TIES
IT IS THE RESPONSIBILITY OF THE USER TO COMPLY WITH ALL APPLICABLE
REGULATIONS AND BUILDING CODE REQUIREMENTS CONCERNING THE USE OF
THESE PRODUCTS.
IT IS FURTHER THE RESPONSIBILITY OF THE USER TO RESEARCH AND UNDERSTAND
SAFE METHODS OF USE AND HANDLING OF THESE PRODUCTS.
Quad-Lock Building Systems
7398 - 132nd Street
Surrey, BC V3W 4M7
Canada
DRAWN BY:
DATE DRAWN:
REVISION NO:
SCALE:
SHEET SIZE:
APPROVED BY:
REVISION DATE: DRAWING NO:
R
Building Systems
APPROVED ON:
888.711.5625 - Toll Free
604.590.3111
604.590.8412 - fax
www.quadlock.com
2016-11-29
2016-11-21
G. KUSTERMANN
8.5" x 11" [216mm x 279mm]
NOT TO SCALE
QLU-212
Z. PROSTRAN
YYYY-MM-DD
N/A
FLOOR AGAINST TOP OF QUAD-LOCK WALL
WOOD JOISTS PARALLEL TO WALL
4" [102mm]
6" [152mm]
8" [203mm]
10" [254mm]
12" [305mm]
14" [356mm]
BLUE TIE =
YELLOW TIE =
GREEN TIE =
RED TIE =
BROWN TIE =
BLACK TIE + XT =
CONCRETE CORE
THICKNESS
TIE NAME
ETC.
QUAD-LOCK R-28 [U-0.21] WALL
NOTE:
FOR PRESCRIPTIVE DESIGN REFER TO PCA-100 OR IRC SECTION R611 OR APPLICABLE BUILDING CODE
FOR SIZING AND OR SPACING OF THE FOLLOWING:
· TENSION TIES (Omitted from this drawing for clarity)
· STRAPPING (Omitted from this drawing for clarity)
· CONT. STEEL PLATE BETWEEN SILL AND RIMBOARD (Omitted from this drawing for clarity)
· SILL PLATE
· ANCHOR BOLTS AND WASHERS
· BLOCKING ETC.
SEE TABLE
3
1
8
" [79mm]3
1
8
" [79mm]
PARGING AS SPECIFIED
MINIMUM 6" EXPOSED ABOVE GRADE
INTERIOR FINISH
STUDS & INSULATION
BOTTOM PLATE
SHEATHING
EXTERIOR FINISH AS SPECIFIED
P.T. SILL PLATE AS SPECIFIED
WITH ANCHOR BOLTS AND SILL SEALER
VAPOR BARRIER
TAPER-CUT QUAD-LOCK PANELS
SUBFLOORBLOCKING AS SPECIFIED
FURRING FOR CEILING FINISH ATTACHMENT
WOOD JOISTS AS SPECIFIED
LEDGER BOARD WITH ANCHOR BOLTS AS SPECIFIED
WATER PROOFING AS SPECIFIED
(QUAD-LOCK PEEL&STICK OR EQ.)
BACKFILL
SLOPE GRADE AWAY FROM WALL
CUT OUT HOLES IN EPS PANELS AND FILL IN WITH CONCRETE
AT EVERY BOLT LOCATION
MIN. 7.25" [185mm] DIAMETER FOR ULTRA PANELS
QUAD-LOCK PLASTIC TIE
SPACED AT 12" [305mm] O/C VER & HOR
INTERIOR WALL FINISH - GYPSUM WALLBOARD OR EQ.
FASTEN TO QUAD-LOCK TIE FLANGES
HORIZONTAL WALL REINFORCEMENT
PLACED ALTERNATELY LEFT AND RIGHT
OF VERTICAL REINFORCEMENT
QUAD-LOCK ULTRA PANEL
3.125" [79mm] THICK EPS
VERTICAL WALL REINFORCEMENT
QUAD-LOCK METAL TRACK
FASTENING SURFACE FOR EXTERIOR FINISH
QUAD-LOCK WIRE TOP TIES
REMOVE & REUSE METAL TRACK
ON INTERIOR AT TOP OF WALLS
IT IS THE RESPONSIBILITY OF THE USER TO COMPLY WITH ALL APPLICABLE
REGULATIONS AND BUILDING CODE REQUIREMENTS CONCERNING THE USE OF
THESE PRODUCTS.
IT IS FURTHER THE RESPONSIBILITY OF THE USER TO RESEARCH AND UNDERSTAND
SAFE METHODS OF USE AND HANDLING OF THESE PRODUCTS.
Quad-Lock Building Systems
7398 - 132nd Street
Surrey, BC V3W 4M7
Canada
DRAWN BY:
DATE DRAWN:
REVISION NO:
SCALE:
SHEET SIZE:
APPROVED BY:
REVISION DATE: DRAWING NO:
R
Building Systems
APPROVED ON:
888.711.5625 - Toll Free
604.590.3111
604.590.8412 - fax
www.quadlock.com
2016-11-29
2016-11-21
G. KUSTERMANN
8.5" x 11" [216mm x 279mm]
NOT TO SCALE
QLU-213
Z. PROSTRAN
YYYY-MM-DD
N/A
FLOOR AGAINST TOP OF QUAD-LOCK WALL
WOOD TRUSSES PERPENDICULAR TO WALL
4" [102mm]
6" [152mm]
8" [203mm]
10" [254mm]
12" [305mm]
14" [356mm]
BLUE TIE =
YELLOW TIE =
GREEN TIE =
RED TIE =
BROWN TIE =
BLACK TIE + XT =
CONCRETE CORE
THICKNESS
TIE NAME
ETC.
QUAD-LOCK R-28 [U-0.21] WALL
NOTE:
FOR PRESCRIPTIVE DESIGN REFER TO PCA-100 OR IRC SECTION R611 OR APPLICABLE BUILDING CODE
FOR SIZING AND OR SPACING OF THE FOLLOWING:
· TENSION TIES (Omitted from this drawing for clarity)
· STRAPPING (Omitted from this drawing for clarity)
· CONT. STEEL PLATE BETWEEN SILL AND RIMBOARD (Omitted from this drawing for clarity)
· SILL PLATE
· ANCHOR BOLTS AND WASHERS
· BLOCKING ETC.
SEE TABLE
3
1
8
" [79mm]3
1
8
" [79mm]
SUBFLOOR
FURRING FOR CEILING FINISH ATTACHMENT
INTERIOR FINISH
STUDS & INSULATION
BOTTOM PLATE
PARGING AS SPECIFIED
MINIMUM 6" EXPOSED ABOVE GRADE
SIDING FINISH
FLOOR TRUSSES AS SPECIFIED
REMOVE QUAD-LOCK EPS AT EVERY TRUSS LOCATION
PRIOR TO INSTALLING TRUSSES
WATER PROOFING AS SPECIFIED
(QUAD-LOCK PEEL&STICK OR EQ.)
BACKFILL
SLOPE GRADE AWAY FROM WALL
QUAD-LOCK PLASTIC TIE
SPACED AT 12" [305mm] O/C VER & HOR
INTERIOR WALL FINISH - GYPSUM WALLBOARD OR EQ.
FASTEN TO QUAD-LOCK TIE FLANGES
HORIZONTAL WALL REINFORCEMENT
PLACED ALTERNATELY LEFT AND RIGHT
OF VERTICAL REINFORCEMENT
QUAD-LOCK ULTRA PANEL
3.125" [79mm] THICK EPS
VERTICAL WALL REINFORCEMENT
P.T. SILL PLATE AS SPECIFIED
WITH ANCHOR BOLTS AND SILL SEALER
DOUBLE INFILL BLOCKING
VERTICAL FURRING STRIPS
MOISTURE BARRIER
SHEATHING
TRUSS BEARING AS SPECIFIED
QUAD-LOCK METAL TRACK
FASTENING SURFACE FOR EXTERIOR FINISH
QUAD-LOCK WIRE TOP TIES
CONTINUOUS INSULATION
IT IS THE RESPONSIBILITY OF THE USER TO COMPLY WITH ALL APPLICABLE
REGULATIONS AND BUILDING CODE REQUIREMENTS CONCERNING THE USE OF
THESE PRODUCTS.
IT IS FURTHER THE RESPONSIBILITY OF THE USER TO RESEARCH AND UNDERSTAND
SAFE METHODS OF USE AND HANDLING OF THESE PRODUCTS.
Quad-Lock Building Systems
7398 - 132nd Street
Surrey, BC V3W 4M7
Canada
DRAWN BY:
DATE DRAWN:
REVISION NO:
SCALE:
SHEET SIZE:
APPROVED BY:
REVISION DATE: DRAWING NO:
R
Building Systems
APPROVED ON:
888.711.5625 - Toll Free
604.590.3111
604.590.8412 - fax
www.quadlock.com
2016-11-29
2016-11-21
G. KUSTERMANN
8.5" x 11" [216mm x 279mm]
NOT TO SCALE
QLU-214
Z. PROSTRAN
YYYY-MM-DD
N/A
FLOOR AGAINST TOP OF QUAD-LOCK WALL
WOOD TRUSSES PARALLEL TO WALL
4" [102mm]
6" [152mm]
8" [203mm]
10" [254mm]
12" [305mm]
14" [356mm]
BLUE TIE =
YELLOW TIE =
GREEN TIE =
RED TIE =
BROWN TIE =
BLACK TIE + XT =
CONCRETE CORE
THICKNESS
TIE NAME
ETC.
QUAD-LOCK R-28 [U-0.21] WALL
NOTE:
FOR PRESCRIPTIVE DESIGN REFER TO PCA-100 OR IRC SECTION R611 OR APPLICABLE BUILDING CODE
FOR SIZING AND OR SPACING OF THE FOLLOWING:
· TENSION TIES (Omitted from this drawing for clarity)
· STRAPPING (Omitted from this drawing for clarity)
· CONT. STEEL PLATE BETWEEN SILL AND RIMBOARD (Omitted from this drawing for clarity)
· SILL PLATE
· ANCHOR BOLTS AND WASHERS
· BLOCKING ETC.
SEE TABLE
3
1
8
" [79mm]3
1
8
" [79mm]
SUBFLOOR
FURRING FOR CEILING FINISH ATTACHMENT
INTERIOR FINISH
STUDS & INSULATION
PARGING AS SPECIFIED
MINIMUM 6" EXPOSED ABOVE GRADE
FLOOR TRUSSES AS SPECIFIED
LATERAL BRACING (STRONGBACK) AS SPECIFIED
P.T. SILL PLATE AS SPECIFIED
WITH ANCHOR BOLTS AND SILL SEALER
WATER PROOFING AS SPECIFIED
(QUAD-LOCK PEEL&STICK OR EQ.)
BACKFILL
SLOPE GRADE AWAY FROM WALL
QUAD-LOCK PLASTIC TIE
SPACED AT 12" [305mm] O/C VER & HOR
INTERIOR WALL FINISH - GYPSUM WALLBOARD OR EQ.
FASTEN TO QUAD-LOCK TIE FLANGES
HORIZONTAL WALL REINFORCEMENT
PLACED ALTERNATELY LEFT AND RIGHT
OF VERTICAL REINFORCEMENT
QUAD-LOCK ULTRA PANEL
3.125" [79mm] THICK EPS
VERTICAL WALL REINFORCEMENT
QUAD-LOCK METAL TRACK
FASTENING SURFACE FOR EXTERIOR FINISH
QUAD-LOCK WIRE TOP TIES
REMOVE & REUSE METAL TRACK
ON INTERIOR AT TOP OF WALLS
SIDING FINISH
VERTICAL FURRING STRIPS
MOISTURE BARRIER
CONTINUOUS INSULATION
DOUBLE INFILL BLOCKING
SHEATHING
BOTTOM PLATE
IT IS THE RESPONSIBILITY OF THE USER TO COMPLY WITH ALL APPLICABLE
REGULATIONS AND BUILDING CODE REQUIREMENTS CONCERNING THE USE OF
THESE PRODUCTS.
IT IS FURTHER THE RESPONSIBILITY OF THE USER TO RESEARCH AND UNDERSTAND
SAFE METHODS OF USE AND HANDLING OF THESE PRODUCTS.
Quad-Lock Building Systems
7398 - 132nd Street
Surrey, BC V3W 4M7
Canada
DRAWN BY:
DATE DRAWN:
REVISION NO:
SCALE:
SHEET SIZE:
APPROVED BY:
REVISION DATE: DRAWING NO:
R
Building Systems
APPROVED ON:
888.711.5625 - Toll Free
604.590.3111
604.590.8412 - fax
www.quadlock.com
2016-11-29
2016-11-21
G. KUSTERMANN
8.5" x 11" [216mm x 279mm]
NOT TO SCALE
QLU-215
Z. PROSTRAN
YYYY-MM-DD
N/A
FLOOR AGAINST TOP OF QUAD-LOCK WALL
TJI'S PERPENDICULAR TO WALL W/ SIMPSON LEDGER CONNECTOR
4" [102mm]
6" [152mm]
8" [203mm]
10" [254mm]
12" [305mm]
14" [356mm]
BLUE TIE =
YELLOW TIE =
GREEN TIE =
RED TIE =
BROWN TIE =
BLACK TIE + XT =
CONCRETE CORE
THICKNESS
TIE NAME
ETC.
QUAD-LOCK R-28 [U-0.21] WALL
SEE TABLE
3
1
8
" [79mm]3
1
8
" [79mm]
PARGING AS SPECIFIED
MINIMUM 6" EXPOSED ABOVE GRADE
WATER PROOFING AS SPECIFIED
(QUAD-LOCK PEEL&STICK OR EQ.)
BACKFILL
INTERIOR FINISH
STUDS & INSULATION
BOTTOM PLATE
QUAD-LOCK ULTRA PANEL
3.125" [79mm] THICK EPS
SLOPE GRADE AWAY FROM WALL
SUBFLOOR
BLOCKING AS SPECIFIED
LEDGER BOARD AS SPECIFIED
ENGINEERED I-JOISTS AS SPECIFIED
FURRING FOR CEILING FINISH ATTACHMENT
SHEATHING
CONTINUOUS INSULATION
VAPOR BARRIER
EXTERIOR FINISH AS SPECIFIED
SIMPSON ICFVL-W (1
9
16
" [40mm] FOR WOOD LEDGER BOARD)
OR SIMPSON ICFVL-CW (1
13
16
" [46mm] FOR LVL LEDGER BOARD
SIMPSON ICFVL
CAST IN PLACE
QUAD-LOCK PLASTIC TIE
SPACED AT 12" [305mm] O/C VER & HOR
HORIZONTAL WALL REINFORCEMENT
PLACED ALTERNATELY LEFT AND RIGHT
OF VERTICAL REINFORCEMENT
VERTICAL WALL REINFORCEMENT
INTERIOR WALL FINISH
GYPSUM WALLBOARD OR EQ.
FASTEN TO QUAD-LOCK TIE FLANGES
P.T. SILL PLATE AS SPECIFIED
WITH ANCHOR BOLTS AND SILL SEALER
QUAD-LOCK METAL TRACK
FASTENING SURFACE FOR EXTERIOR FINISH
QUAD-LOCK WIRE TOP TIES
REMOVE & REUSE METAL TRACK
ON INTERIOR AT TOP OF WALLS
IT IS THE RESPONSIBILITY OF THE USER TO COMPLY WITH ALL APPLICABLE
REGULATIONS AND BUILDING CODE REQUIREMENTS CONCERNING THE USE OF
THESE PRODUCTS.
IT IS FURTHER THE RESPONSIBILITY OF THE USER TO RESEARCH AND UNDERSTAND
SAFE METHODS OF USE AND HANDLING OF THESE PRODUCTS.
Quad-Lock Building Systems
7398 - 132nd Street
Surrey, BC V3W 4M7
Canada
DRAWN BY:
DATE DRAWN:
REVISION NO:
SCALE:
SHEET SIZE:
APPROVED BY:
REVISION DATE: DRAWING NO:
R
Building Systems
APPROVED ON:
888.711.5625 - Toll Free
604.590.3111
604.590.8412 - fax
www.quadlock.com
2016-11-29
2016-11-21
G. KUSTERMANN
8.5" x 11" [216mm x 279mm]
NOT TO SCALE
QLU-216
Z. PROSTRAN
YYYY-MM-DD
N/A
FLOOR AGAINST TOP OF QUAD-LOCK WALL
TJI'S PARALLEL TO WALL W/ SIMPSON LEDGER CONNECTOR
4" [102mm]
6" [152mm]
8" [203mm]
10" [254mm]
12" [305mm]
14" [356mm]
BLUE TIE =
YELLOW TIE =
GREEN TIE =
RED TIE =
BROWN TIE =
BLACK TIE + XT =
CONCRETE CORE
THICKNESS
TIE NAME
ETC.
QUAD-LOCK R-28 [U-0.21] WALL
SEE TABLE
3
1
8
" [79mm]3
1
8
" [79mm]
INTERIOR FINISH
STUDS & INSULATION
BOTTOM PLATE
ENGINEERED I-JOISTS AS SPECIFIED
FURRING FOR CEILING FINISH ATTACHMENT
SIMPSON ICFVL-W (1
9
16
" [40mm] FOR WOOD LEDGER BOARD)
OR SIMPSON ICFVL-CW (1
13
16
" [46mm] FOR LVL LEDGER BOARD
SIMPSON ICFVL
CAST IN PLACE
WATER PROOFING AS SPECIFIED
(QUAD-LOCK PEEL&STICK OR EQ.)
BACKFILL
QUAD-LOCK ULTRA PANEL
3.125" [79mm] THICK EPS
SLOPE GRADE AWAY FROM WALL
QUAD-LOCK PLASTIC TIE
SPACED AT 12" [305mm] O/C VER & HOR
HORIZONTAL WALL REINFORCEMENT
PLACED ALTERNATELY LEFT AND RIGHT
OF VERTICAL REINFORCEMENT
VERTICAL WALL REINFORCEMENT
INTERIOR WALL FINISH
GYPSUM WALLBOARD OR EQ.
FASTEN TO QUAD-LOCK TIE FLANGES
PARGING AS SPECIFIED
MINIMUM 6" EXPOSED ABOVE GRADE
SHEATHING
CONTINUOUS INSULATION
VAPOR BARRIER
EXTERIOR FINISH AS SPECIFIED
QUAD-LOCK METAL TRACK
FASTENING SURFACE FOR EXTERIOR FINISH
QUAD-LOCK WIRE TOP TIES
SUBFLOOR
BLOCKING AS SPECIFIED
LEDGER BOARD AS SPECIFIED
P.T. SILL PLATE AS SPECIFIED
WITH ANCHOR BOLTS AND SILL SEALER
REMOVE & REUSE METAL TRACK
ON INTERIOR AT TOP OF WALLS
IT IS THE RESPONSIBILITY OF THE USER TO COMPLY WITH ALL APPLICABLE
REGULATIONS AND BUILDING CODE REQUIREMENTS CONCERNING THE USE OF
THESE PRODUCTS.
IT IS FURTHER THE RESPONSIBILITY OF THE USER TO RESEARCH AND UNDERSTAND
SAFE METHODS OF USE AND HANDLING OF THESE PRODUCTS.
Quad-Lock Building Systems
7398 - 132nd Street
Surrey, BC V3W 4M7
Canada
DRAWN BY:
DATE DRAWN:
REVISION NO:
SCALE:
SHEET SIZE:
APPROVED BY:
REVISION DATE: DRAWING NO:
R
Building Systems
APPROVED ON:
888.711.5625 - Toll Free
604.590.3111
604.590.8412 - fax
www.quadlock.com
2016-11-29
2016-11-21
G. KUSTERMANN
8.5" x 11" [216mm x 279mm]
NOT TO SCALE
QLU-217
Z. PROSTRAN
YYYY-MM-DD
N/A
OWSJ FLOOR ON TOP OF QUAD-LOCK WALL
JOISTS PERPENDICULAR TO WALL
4" [102mm]
6" [152mm]
8" [203mm]
10" [254mm]
12" [305mm]
14" [356mm]
BLUE TIE =
YELLOW TIE =
GREEN TIE =
RED TIE =
BROWN TIE =
BLACK TIE + XT =
CONCRETE CORE
THICKNESS
TIE NAME
ETC.
QUAD-LOCK R-28 [U-0.21] WALL
SEE TABLE
3
1
8
" [79mm]3
1
8
" [79mm]
PARGING AS SPECIFIED
MINIMUM 6" EXPOSED ABOVE GRADE
SIDING FINISH
INTERIOR FINISH
STUDS & INSULATION
VERTICAL FURRING STRIPS
VAPOR BARRIER
FURRING FOR CEILING FINISH ATTACHMENT
OPEN WEB STEEL JOISTS (OWSJ) AS SPECIFIED
STEEL PLATE W/ WELDED HEADED STUD ANCHOR
AT EVERY JOIST - AS SPECIFIED
REBAR DOWELS AS SPECIFIED
FLOOR FINISH AS SPECIFIED
TOP OF WALL REINFORCEMENT AS SPECIFIED
QUAD-LOCK WALL PANELS MITERED AT TOP
PROVIDES CONCRETE SUPPORT TO BOTTOM PLATE ABOVE
CORRUGATED STEEL DECK AS SPECIFIED
STARTER STRIP
SHEATHING
SLAB REINFORCEMENT AS SPECIFIED
BOTTOM PLATE WITH SILL SEALER AND ANCHOR BOLTS
INDENT FROM OUTSIDE OF WALL EPS BY SHEATHING THICKNESS
WATER PROOFING AS SPECIFIED
(QUAD-LOCK PEEL&STICK OR EQ.)
BACKFILL
QUAD-LOCK ULTRA PANEL
3.125" [79mm] THICK EPS
SLOPE GRADE AWAY FROM WALL
QUAD-LOCK PLASTIC TIE
SPACED AT 12" [305mm] O/C VER & HOR
HORIZONTAL WALL REINFORCEMENT
PLACED ALTERNATELY LEFT AND RIGHT
OF VERTICAL REINFORCEMENT
VERTICAL WALL REINFORCEMENT
INTERIOR WALL FINISH
GYPSUM WALLBOARD OR EQ.
FASTEN TO QUAD-LOCK TIE FLANGES