IndianaMeter Mounting Equipment
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
2
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
MILBANKOVERVIEW
Milbank OverviewEnergy At Work since 1927
Milbank designs and manufactures electrical solutions that move and manage power for the residential, commercial, industrial, utility and transportation sectors. With 90 years of expertise in electrical engineering design and manufacturing, Milbank’s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 1927, Milbank is a family-owned, American manufacturer headquartered in Kansas City, Mo. For more information, please visit milbankworks.com.
As a market leader in electrical metering equipment, Milbank has set the standard for quality since 1927. Hundreds of configurations are available, including many sizes, knockout configurations, terminal configurations, bypass options, hubs, locks and connectors. Milbank has the socket you need with thousands of active products to meet your utility’s requirements.
Milbank doesn’t just build empty enclosures. We can deliver the entire package, complete with custom control equipment built to your exact specifications by our engineers. Milbank commercial pedestals are an attractive, secure, easy to install and cost-effective solution when underground remote site power distribution and control equipment is required, replacing unsightly and inefficient strut and backboard structures.
Milbank’s line of enclosures include commercial junction boxes, panel mount enclosures, transformer cabinets, wireway, trough and industrial panel mount and push-button enclosures. Built with high-quality craftsmanship and materials which meet or exceed industry standards, Milbank enclosures are made to protect controls and equipment from dust, dirt and other harmful elements found in a wide variety of environments.
METERING
ENCLOSED CONTROLS
ENCLOSURES
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
3
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
TABLE OFCONTENTS
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Table of Contents
Air Conditioner Disconnects
30-60 amp AC disconnects .............................................................................................................................................. 660 amp AC disconnect with 20 amp GFCI receptacle ....................................................................................................... 7Hot tub disconnects .......................................................................................................................................................... 8
Single Position Sockets
125-200 amp, 4 terminal, ringless .................................................................................................................................... 9 200 amp, 4, 5 & 7 terminal, ringless, lever bypass ........................................................................................................ 10320 amp, 4 terminal, ringless, side wireway, lever bypass ............................................................................................. 11320 amp, 7 terminal, side wireway, ringless, lever bypass ............................................................................................ 12
Unmetered Load Centers
200 amp, unmetered load center with main breaker ...................................................................................................... 13
Meter Mains
125-200 amp, 4 terminal, ringless .................................................................................................................................. 14200 amp, 4 terminal, load center, ringless, horn bypass ................................................................................................ 15200 amp, 4 & 7 terminal, ringless, lever bypass ............................................................................................................. 16320 amp, 4 terminal, ringless, lever bypass ................................................................................................................... 17400 amp, 4 & 5 terminal, ringless ................................................................................................................................... 18400 amp, 7 terminal, ringless .......................................................................................................................................... 19200-400 amp, 4, 5 & 7 terminal, ringless ........................................................................................................................ 20
Multi-Position Sockets
150 amp, 4 terminal, ringless .......................................................................................................................................... 21200 amp, 4 terminal, ringless .......................................................................................................................................... 22Knockout information ..................................................................................................................................................... 23
Lever Bypass Multi-Position Sockets
200 amp, 5 terminal, ringless .......................................................................................................................................... 24200 amp, 7 terminal, ringless .......................................................................................................................................... 25
Multi-Position Meter Mains
125-200 amp, 4 terminal, ringless .................................................................................................................................. 26Knockout information ..................................................................................................................................................... 27125-200 amp, 4 terminal, ringless .................................................................................................................................. 28Dimensional information ................................................................................................................................................. 29
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
4
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
Table of Contents
Transformer Rated Sockets
20 amp, 6-13 terminal, plunger bypass .......................................................................................................................... 3020 amp, 6-13 terminal, test switch provision .................................................................................................................. 3180 amp, 6, 8 &13 terminal, lever bypass ....................................................................................................................... 32Test Switches ............................................................................................................................................................. 33-34Current transformer cabinet, panel enclosure ................................................................................................................ 35
Multi-Position Tap Box
3 phase, aluminum construction, wall or pad mountable ........................................................................................... 36-37
Meter Main with Load Center Pedestal
100-200 amp, 4 terminal, ringless ............................................................................................................................. 38-39
Temp Power
125 amp, 4 terminal, ringless .......................................................................................................................................... 40125 amp, surface mount, Millennium Series .................................................................................................................. 41125 amp, power outlet pedestal .................................................................................................................................... 42
Miscellaneous
Circuit Breakers ......................................................................................................................................................... 43-44Accessories ................................................................................................................................................................ 45-47Commercial Pedestals ................................................................................................................................................ 48-57Reference Information ............................................................................................................................................... 58-62Index .......................................................................................................................................................................... 63-65
MILBANKOVERVIEW
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
5
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
Catalog Number LogicHow our product catalog numbers are derived
CATALOGNUMBERLOGIC
U7040-RL-TG-KK-5T9-BL-AUT
Milbankdrawingnumber
Utilityspecific
designation
TG: Triplex groundQG: Quadplex ground
5th terminal designation5T6: installed at 6:005T9: installed at 9:00
U: UL ListedS: Non-UL Listed
UAP: UL, aluminum, painted KK: Horn bypass BL: Barrel lock
Hub Openings & Closing Plates-O Blank top-RL Small hub opening-R Large hub opening-XL Small closing plate-XT (2) Large Closking plates-XTL (2) Small closking plates-X Large closing plate-RXL Large hub opening adapted to small closing plate-RRL Large hub opening adapted to small hub opening
U2448-X-QG-5T9-K3-BLG-ARE
Milbankdrawingnumber
Utilityspecific
designation
TG: Triplex groundQG: Quadplex ground
5th terminal designation5T6: installed at 6:005T9: installed at 9:00
U: UL ListedS: Non-UL Listed
UAP: UL, aluminum, painted
Lugs (1Ø or 3Ø,350 or 600 kcmil)
Single: K1, K3, K5, K7Twin: K2, K4, K6, K8
BLG: Barrel lock / guard provision
-PXL Closing plate packed inside-WL 1” hub-YL 1¼” hub-ZL 1½” hub-DL 2” hub-EL 2½” hub-F 3” hub -G 3½” hub -H 4” hub
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
6AC
DISCONNECTS
Air Conditioner Disconnects30-60 Amps | Fusible & Non-Fusible
Catalog Number
Amps TypeMax H.P.
Weight(lbs.)
Line/Load Wire Range Ground Wire
Range CU/ALDimensions Wire Rating
CU AL D" W" H" CU °C AL °C
U3802 60 Non-Fusible 10 3.25 #14-#2 #12-#2 #14-4 21⁄2 5 71⁄2 60°/75° 60°/75°
U3812 60 Non-Auto 10 3.25 #14-#2 #12-#2 #14-4 21⁄2 5 71⁄2 60°/75° 60°/75°
U3832 30 Fusible 3 2.5 #14-#3 #14-#3 #14-3 21⁄8 5 7 60°/75° 60°/75°
U3862 60 Fusible 10 3.3 #14-#3 #14-#3 #14-3 21⁄8 5 9 60°/75° 60°/75°
30–60 Amps | 1Ø 240 VAC | Air Conditioner Disconnects
Notes
• UL listed as Enclosed Pullout Switch• Type 3R rain resistant• One-inch concentric knockouts
U3832U3812U3802
Milbank’s air conditioner disconnect has a removable hinged cover for ease of installation. Our compact design meets NEC wiring space requirements and also complies with NEC article 440-14. For safe working conditions, our disconnect pullers may be removed and reinstalled in the OFF position. Additionally, padlock provisions are included on the front cover. As with other Milbank products, our enclosure is constructed of G90U galvanized steel and electrostatically finished with an attractive, light gray, baked powder coating. Our epoxy/polyester resin blend offers a finish that is both durable and fade-resistant.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
7
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
Air Conditioner Disconnects20 Amp GFCI Receptacle
ACDISCONNECTS
CatalogNumber
TypeMax H.P.
Weight(lbs.)
Line/Load Wire Range
Ground Wire Range
CU/AL
Dimensions Wire Rating
CU AL D" W" H" CU °C AL °C
U3822-20GWR Non-Fusible 10 6 #14-#2 #12-#2 #14-4 44⁄5 51⁄4 72⁄5 60°/75° 60°/75°
60 Amps | 1Ø, 240 VAC | Air Conditioner Disconnect with GFCI Receptacle
Notes
• Disconnect Pullers: To ensure the safest conditions, Milbank disconnect pullers are reversible so they may be reinstalled in the OFF position.• Padlock Provision: All units are designed with a padlock provision on the cover for security.• *In-Use Cover: Cover is rated as an in-use cover (cover may be closed with cords plugged into receptacle).
• Meets NEC #210.63 requirements• UL listed as Power Outlet• Type 3R enclosure• In-use cover*• Duplex ground connector• 1" concentric knockouts
• 1Ø, 240 volt• 60 amp, non-fused• 20 amp GFCI receptacle• Reset/test button• Weather and tamper resistant• Meets NEC #406.8 requirements
SpecificationsU3822-20GWR
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
8
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
HOT TUBDISCONNECTS
Hot Tub DisconnectsType 3R Enclosures
U4881-O-50GB U4881-O-60GB
Catalog Number
Breaker Amps
TypeWeight(lbs.)
Line/LoadWire Range
Ground Wire Range
CU/AL
Dimensions
CU AL D" W" H"
U4881-O-50GB 50 Breaker 8 #14-1/0 #14-1/0 #14-1/0 33⁄4 71⁄2 81⁄2
U4881-O-60GB 60 Breaker 8 #14-1/0 #14-1/0 #14-1/0 33⁄4 71⁄2 81⁄2
100 Amps | Hot Tub Disconnect or Sub Panel Breaker Enclosure | Type 3R
Specifications
• 240 volt ground fault protection• UL listed, Type 3R rain resistant• 2-pole, 50 or 60 amp GFCI breaker protection• Compact size• Three or four wire installation
• 1Ø, 120/240 VAC• Standard package of 12• Two extra one-pole breaker spaces• 100 amp overall rating• Easy to install
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
9
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
125-200 AMPSINGLE
POSITION
Single Position Sockets125-200 Amp | 4 Terminal | Ringless | 600 VAC
Catalog Number Amps Service HubConnectors CU/AL
BypassDimensions Knockouts
Line Load D" W" H" 1 2 3 4
U7487-RL-TG-KK 125 OH/UG H.O. #6-2/0 #6-2/0 Horn 35⁄16 8 111⁄2 2 11⁄2 11⁄4 1⁄4
U7487-RL-TG-KK-BLG 125 OH/UG H.O. #6-2/0 #6-2/0 Horn 35⁄16 8 111⁄2 2 — 11⁄4 1⁄4
U7021-RL-TG-KK 200 OH H.O. #6-350 #6-350 Horn 41⁄8 8 151⁄2 21⁄2 1⁄4,1⁄2 1⁄4 —
U7021-RL-TG-KK-BLG 200 OH H.O. #6-350 #6-350 Horn 41⁄8 8 151⁄2 21⁄2 1⁄4,1⁄2 1⁄4 —
U7040-RL-TG-KK 200 OH/UG H.O. #6-350 #6-350 Horn 41⁄8 11 145⁄8 21⁄2 1⁄4,1⁄2 1⁄4 —
U7040-RL-TG-KK-BLG 200 OH H.O. #6-350 #6-350 Horn 41⁄8 11 145⁄8 21⁄2 1⁄4,1⁄2 1⁄4 —
U7040-XL-TG-KK 200 OH/UG C.P. #6-350 #6-350 Horn 41⁄8 11 145⁄8 21⁄2 1⁄4,1⁄2 1⁄4 —
U4532-XL 200 OH/UG C.P. #6-350 (2) #6-350 None 47⁄8 15 201⁄2 3 21⁄2 1⁄4,1⁄2 1⁄4
Catalog Number Service HubConnectors CU/AL
BypassDimensions Knockouts
Line Load D" W" H" 1 2 3 4
U1980-O-KK UG Blank #6-350 #6-350 Horn 41⁄2 13 151⁄4 3 21⁄2 11⁄2 1⁄4,1⁄2
U1980-O-KK-BLG UG Blank #6-350 #6-350 Horn 41⁄2 13 151⁄4 31⁄2 21⁄2 11⁄2 1⁄4,1⁄2
4 Terminal | Single Position | Ringless | 1Ø3W
200 Amp | 4 Terminal | Single Position | Ringless | Side Wireway | 1Ø3W
Notes
• Hubs: Order hubs separately — see accessory page for ordering information.• Fifth Terminal: For field mounted fifth terminal for U7021, U7040, U4532 and U1980, order catalog number K5T. For the U7487, order catalog number 5T8K2.• Connectors: Extruded aluminum connectors are tin plated.• U4532: Includes twin lug connector on load side.• Tap Connector: For tap connector, order K4977-INT.• Product numbers with BLG are used in AEP service areas.
7040
1 1
1
2 3
1 1
1
2 3
1 1BLG BOTTOM
74871
2 2
4
33
1
4
3 BLG BOTTOM
45321 1 1
2 2
34
70211 23
1 1
1
2 2
23 41980
U7487-RL-TG-KK U7040-RL-TG-KK U4532-XL U1980-O-KK
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
10
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
Single Position Lever Bypass200 Amp | 4, 5 & 7 Terminal | Ringless | 600 VAC
200 AMPSINGLE
POSITIONLEVER BYPASS
CatalogNumber
Terminal Phase Service HubConnectors
CU/ALDimensions Knockouts
D" W" H" 1 2 3 4
U3278-RL 4 1Ø3W OH H.O. #6-350 41⁄8 11 151⁄2 21⁄2 2 1⁄4,1⁄2 1⁄4
CatalogNumber
Terminal Phase Service HubConnectors
CU/ALDimensions Knockouts
D" W" H" 1 2 3 4
U9551-RRL 5 1Ø3W or 3Ø3W OH/UG H.O. #6-350 47⁄8 13 19 3 21⁄2 1⁄4,1⁄2 1⁄4
U9701-RRL* 7 3Ø4W OH/UG H.O. #6-350 47⁄8 13 19 3 21⁄2 1⁄4,1⁄2 1⁄4
U9701-X-QG-BLG* 7 3Ø4W OH/UG C.P. #6-350 47⁄8 13 19 3 21⁄2 1⁄4,1⁄2 1⁄4
200 Amp | Single Position | Lever Bypass | Ringless | Non-Jaw Clamping
200 Amp | Single Position | Heavy Duty Lever Bypass | Ringless | Jaw Clamping
Notes
• Hubs: For proper hub selection, see the hub suffix chart on the accessory page.• Connectors: Extruded aluminum connectors are tin plated.• Bypass: The lever on the U3278 unit operates the bypass device only; it does not provide clamping action on the meter spades. The levers on the U9551 and U9701 units supply clamping action on meter spades and also operate the bypass devices.• Product numbers with BLG are used in AEP service areas.* Can be used in a 100 A 3 phase applications due to lug range.
U3278-RL U9551-RRL U9701-RRL
1
1
1
22
3 4
3278 95519701
1
34
1 1 1
2
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
11
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
320 AMPSINGLE
POSITIONLEVER BYPASS
Single Position Lever Bypass320 Amp | 4 Terminal | Ringless | 600 VAC
Catalog Number Service HubConnectors CU/AL
BypassDimensions Knockouts
Line Load D" W" H" 1 2 3 4
U4363-X-QG-K3-K2 OH C.P. (1) #4-600 or (2) 1/0-250 (2) #6-350 Lever 47⁄8 13 281⁄4 3 1⁄4,1⁄2 1⁄4 —
U1079-RRL-K3 OH H.O. (1) #4-600 or (2) 1/0-250
3⁄8" x 16 Studs Lever 47⁄8 13 383⁄4 3 21⁄2 1⁄4,1⁄2 1⁄4
U4905-X OH/UG C.P. 3⁄8" x 16 Studs 3⁄8" x 16 Studs Lever 53⁄4 16 383⁄4 4 31⁄2 3 1⁄4,1⁄2
U4905-X-BLG OH/UG C.P. 3⁄8" x 16 Studs 3⁄8" x 16 Studs Lever 53⁄4 16 383⁄4 4 31⁄2 3 1⁄4,1⁄2
U5161-X-K3L-K2L-BLG OH/UG C.P. (1) #4-600 or (2) 1/0-250 (2) #6-350 Lever 47⁄8 15 31⁄2 3 1⁄4,1⁄2 1⁄4 —
U1129-O-K3L-K2L UG Blank (1) #4-600 or (2) 1/0-250 (2) #6-350 Lever 47⁄8 15 30 3 1⁄4,1⁄2 1⁄4 —
U1797-O-K3L-K2L UG Blank (1) #4-600 or (2) 1/0-250
(2) #6-350 Lever 47⁄8 15 30 3 1⁄4,1⁄2 1⁄4 —
U1797-O-K3L-K2L-BLG UG Blank (1) #4-600 or (2) 1/0-250
(2) #6-350 Lever 47⁄8 15 30 3 1⁄4,1⁄2 1⁄4 —
320 Amp Continuous (400 Amp Max) | 4 Terminal | Single Position | Ringless | 1Ø3W
Notes
• Side Wireway: U1797 and U4905 are side wireway units.• Bypass: Lever supplies clamping action and also operates bypass device.• Hubs: For proper hub selection, see the hub suffix chart on the accessory page.• Connectors: Some units supplied with 3⁄8" x 16 hex head nuts with Belleville washers. For connector kits, order as extra
K1540 (single 600 kcmil). For twin lug connectors, order as extra K1350 (twin 350 kcmil). Order two kits to cover both line and load on U4905 and one kit for load side of U1079.
• Fifth Terminal: For factory-installed fifth terminal in the 6 o’clock position, add the suffix -5T6 to the catalog number. For factory-installed fifth terminal in the 9 o’clock position, add the suffix -5T9 to the catalog number. For field-installed fifth terminal, order as extra catalog number K3865 for U1129, U1797 and U4905 and K3866 for U1079.• Product numbers with BLG are used in AEP service areas.
U1797-O-K3L-K2L
1797
1 1
123
11
U1129-O-K3L-K2L
11295161
1 1
23
1 1 1
U1079-RRL-K3
10794363
1
111
2
34
4905
22
1 1
43
U4363-X-QG-K3-K2
1 1
111
23
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
12
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
Single Position Lever Bypass320 Amp | 7 Terminal | Ringless | 600 VAC
320 AMPSINGLE
POSITIONLEVER BYPASS
320 Amp | 7 Terminal | Single Position | Ringless | Side Wireway | 3Ø4W
Notes
• Hubs: For proper hub selection, see the hub suffix chart on the accessory page.• Bypass: Lever supplies clamping action and also operates bypass device.• Connectors: Supplied with 3⁄8" x 16 hex head nuts with Belleville washers. For connector kits, order as extra K3441 (single 600 kcmil). For twin lug connectors, order as extra K3442 (twin 350 kcmil). Separate kits are required for both line and load. Line side connectors furnished on U2120.• Product numbers with BLG are used in AEP service areas.
2120 2594
U2120-X-K7 U2594-X
1
3
4
1
2
1
2
13
4
1
Catalog Number Service HubConnectors CU/AL
BypassDimensions Knockouts
Line Load D" W" H" 1 2 3 4
U2594-X OH/UG C.P. 3⁄8" x 16 Studs 3⁄8" x 16 Studs Lever 61⁄2 19 341⁄8 4 3 1 1⁄4
U2594-X-BLG OH/UG C.P. 3⁄8" x 16 Studs 3⁄8" x 16 Studs Lever 61⁄2 19 341⁄8 4 3 1 1⁄4
U2120-X-K7 UG C.P. (1) #4-600 or (2) 1/0-250
3⁄8" x 16 Studs Lever 61⁄2 173⁄4 313⁄4 4 3 1 1⁄4
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
13
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
Unmetered Load Centers200 Amp | 120/240 VAC
200 AMPUNMETERED
LOAD CENTERS
200 Amp | Unmetered Load Center with Main Breaker
Notes
• AIC Rating: This units are rated 22K AIC.• Breaker Interlock: U5971 accepts breaker interlock kits — order K5815 for large QN with small frame Q, K5820 for large frame QN with large frame QN, or K5830 for small frame Q to small frame Q.
Catalog NumberMain Breaker
AmpCircuits Service Hub
Dimensions Knockouts
D" W" H" 1 2 3 4 5
USE-22-200-MB 200 4 OH 2" 4 8 23 2 1 1⁄2,3⁄4 — —
U5971-XL-100 100 10 OH/UG C.P. 41⁄2 141⁄8 251⁄16 3 2 1 1⁄2,3⁄4 1⁄4,1⁄2
U5971-XL-150 150 8 OH/UG C.P. 41⁄2 141⁄8 251⁄16 3 2 1 1⁄2,3⁄4 1⁄4,1⁄2
U5971-XL-200 200 8 OH/UG C.P. 41⁄2 141⁄8 251⁄16 3 2 1 1⁄2,3⁄4 1⁄4,1⁄2
12
3 3
3
U5971-XL-200USE-22-200-MB
1 2
35 4
43 4
2
5971USE-22
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
14
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
125 & 200 AMPMETER MAINS
Meter Mains125-200 Amp | 4 Terminal | Ringless | 120/240 VAC
Catalog Number Service Amp HubConnectors CU/AL
BypassDimensions Knockouts
Line Load D" W" H" 1 2 3 4 5
U3989-XL OH/UG 125 C.P. #6-2/0 CB None 33⁄4 11 22 2 1⁄4,1⁄2 — — —
U3491-XL-200 OH/UG 200 C.P. #2-350 CB None 41⁄8 12 29 21⁄2 2 1⁄4 — —
U5844-PXL-200-KK OH/UG 200 C.P. #6-350 CB Horn 41⁄2 14 30 3 21⁄2 1 1⁄2,3⁄4 1⁄4,1⁄2
U5844-PXL-200-KK-BLG OH/UG 200 C.P. #6-350 CB Horn 41⁄2 14 30 3 21⁄2 1 1⁄2,3⁄4 1⁄4,1⁄2
4 Terminal | Meter Mains | Ringless | 1Ø3W
Notes
• Hubs: For proper hub selection, see the hub suffix chart on the accessory page.• Breaker: For replacement breakers for U5844 order QN2200H. For U3989, order approved small frame breakers 125 amps or less per the rating label.• Fifth Terminal: For field installable fifth terminal kit, order K5T.• AIC Rating: The U5844 is 22K AIC rated.• PXL - Closing plate packed inside of carton.• Product numbers with BLG are used in AEP service areas.
34913989 5844
U5844-PXL-200-KKU3491-XL-200U3989-XL
1
1 1 2
3
1 1 1 2
35
3
3
4
4
4
4
2 2 21
1 1 2 1
1
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
15
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
200 AMPMETER MAINWITH LOAD
CENTER
Meter Main With Load Center200 Amp | 4 Terminal | Ringless | 120/240 VAC
Catalog NumberBreaker Amps
Circuits Service HubConnectors CU/AL - Line
Dimensions
D" W" H"
U5168-XTL-100-KK 100 10 OH/UG C.P. #6-350 41⁄2 141⁄8 32
U5168-XTL-100-KK-BLG 100 10 OH/UG C.P. #6-350 41⁄2 141⁄8 32
U5168-XTL-150-KK 150 8 OH/UG C.P. #6-350 41⁄2 141⁄8 32
U5168-XTL-150-KK-BLG 150 8 OH/UG C.P. #6-350 41⁄2 141⁄8 32
U5168-XTL-200-KK 200 8 OH/UG C.P. #6-350 41⁄2 141⁄8 32
U5168-XTL-200-KK-BLG 200 8 OH/UG C.P. #6-350 41⁄2 141⁄8 32
U5268-XTL-150-KK 150 20 OH/UG C.P. #6-350 41⁄2 141⁄8 32
U5268-XTL-200-KK 200 20 OH/UG C.P. #6-350 41⁄2 141⁄8 32
U5268-XTL-200-KK-BLG 200 20 OH/UG C.P. #6-350 41⁄2 141⁄8 32
U5898-O-200-KK-BLG 200 8 OH/UG C.P. #6-350 41⁄2 17 341⁄2
U5898-O-100-KK-BLG 100 8 OH/UG C.P. #6-350 41⁄2 17 341⁄2
Knockouts
1 2 3 4 5 6
3 21⁄2 2 1 1⁄2,3⁄4 1⁄4,1⁄2
200 Amp | 4 Terminal | Meter Mains | Horn Bypass | Ringless | 1Ø3W
Notes
• Fifth Terminal: For field installed fifth terminal, order K5T.• Breakers: Rated 22K AIC with QN2200H main installed for U5168 and U5268.• Sub Feed Lugs: #6-350 sub feed lugs provided on 8 circuit interior. Not available on 20 circuit interior.• Main Lug Kit: Main lug feed-through kit K3701 available.• XTL - Two small hub closing plate.• Product numbers with BLG are used in AEP service areas.
U5168-XTL-200-KK U5268-XTL-200-KK
1 2
3 3 3
4 56
54
5 516852685898
K5815Large QN with small frame Q
K5820 Large frame QN with large frame QN
K5830 Small frame Q to small frame Q
Generator Interlock — for use with U5168 and U5268
AIC Rating Amps Siemens Cutler Hammer General Electric Square D
10k150-200 QNR BR (150A only) — —
≤ 125 QP HQP, BR THQL, THQL-GF Homeline
22k150-200 QNRH — — —
≤ 125 QPH — — —
Branch Breaker Chart
Catalog Number Service Amp HubConnectors CU/AL
BypassDimensions Knockouts
Line Load D" W" H" 1 2 3 4 5
U3989-XL OH/UG 125 C.P. #6-2/0 CB None 33⁄4 11 22 2 1⁄4,1⁄2 — — —
U3491-XL-200 OH/UG 200 C.P. #2-350 CB None 41⁄8 12 29 21⁄2 2 1⁄4 — —
U5844-PXL-200-KK OH/UG 200 C.P. #6-350 CB Horn 41⁄2 14 30 3 21⁄2 1 1⁄2,3⁄4 1⁄4,1⁄2
U5844-PXL-200-KK-BLG OH/UG 200 C.P. #6-350 CB Horn 41⁄2 14 30 3 21⁄2 1 1⁄2,3⁄4 1⁄4,1⁄2
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
16
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
Meter Mains200 Amp | 4 & 7 Terminal | Lever Bypass | Ringless
200 AMPLEVER BYPASSMETER MAINS
200 Amp | Meter Main | Lever Bypass | Ringless
Notes
• Breakers: U5871 is rated 22K AIC with QN2200RH main installed. U5750 is rated 10K AIC with UQFB-3200 main installed.• U5871- Has 8 branch circuits• -BL: Barrel lock• Fifth Terminal: For field installed fifth terminal for U5871, order K5T.• Interlock Kit: For generator auxiliary circuit breaker interlock for U5871, order K5815 for large QN with small frame Q; order K5820 for large frame QN with large frame QN.
Catalog Number TerminalsBreakerAmps
Service HubConnectorsCU/AL - Line
Dimensions Knockouts
D" W" H" 1 2 3 4 5 6
U5871-XL-200 4 200 OH/UG C.P. #6-350 41⁄2 141⁄8 32 3 21⁄2 2 1 1⁄2,3⁄4 1⁄4,1⁄2
U5750-RXL-200-BL 7 200 OH/UG C.P. #6-350 53⁄4 173⁄8 34 4 3 1 1⁄4 — —
1
2 2
2 34
U5750-RXL-200-BL
57501 2
3 3 3
4 56
5
45
U5871-XL-200
5871
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
17
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
320 AMPLEVER BYPASSMETER MAINS
Lever Bypass Meter Mains320 Amp | 4 Terminal | Ringless | 120/240 VAC
Catalog Number HubConnectors CU/AL - Line
BreakerAmps
Branch Circuits
Dimensions Knockouts
D" W" H" 1 2 3 4 5 6
U5059-X-K3L C.P. (1) #4-600 or (2) 1/0-250 Provision N/A 47⁄8 15 42 3 1⁄4,1⁄2 1⁄4 — — —
U5059-X-2/200-K3L C.P. (1) #4-600 or (2) 1/0-250 200 N/A 47⁄8 15 42 3 1⁄4,1⁄2 1⁄4 — — —
U5890-X-2/200-BL* C.P. 3⁄8" x 16 Studs 200 N/A 6 241⁄2 35 4 21⁄2 1⁄4 — — —
U5890-X-2/200-BLG C.P. 3⁄8" x 16 Studs 200 N/A 6 241⁄2 35 4 21⁄2 1⁄4 — — —
U5891-X-2/200-MLK-BL* C.P. 3⁄8" x 16 Studs 200 12 6 291⁄2 35 4 21⁄2 1 1⁄2,3⁄4 1⁄4 —
U4835-X-2/200-BL C.P. 3⁄8" x 16 Studs 200 N/A 53⁄4 247⁄8 30 4 3 1⁄2 — — —
320 Amp | 4 Terminal | Meter Mains | Lever Bypass | Ringless | OH/UG
Notes
• AIC Rating: 22K AIC standard.• Breakers: For U5059 main breakers, order UQFPH-100, -150, or -200. For replacement main breaker in U4835 order
Milbank UQFBH series• -MLK: Main Lug feed-through kit K3701 factory installed.• Fifth Terminal: For field mounted fifth terminal order catalog number K3865.• Connectors: Supplied with 3⁄8" x 16 hex head nuts with Belleville washers. For connector kits, order as extra K1540 (single
600 kcmil). For twin lug connectors, order as extra K1350 (twin 350 kcmil). The extra stud on line side is a wire stop.• Product numbers with BLG are used in AEP service areas (Suffix -BLG is barrel lock with gaurd.)* Barrel lock (suffix -BL)• For replacement main breaker in U5890 order Siemens QN series QN2200H.• For replacement main breaker in U5891, order QN2200H (for left breaker) and a QN2200RH (for right breaker).
U5890-X-2/200-BL(shown with lugs installed)
U5059-X-2/200 U5891-X-2/200-MLK-BL U4835-X-2/200-BL
1
2
2
3
2
22
2
5
3
3 3
4
4 4
1
2
258905891 4835
1
1 1 123
1 1
5059 1
2 2
2
3
2
2
1 2
3 3 3
4 56
54
5 5168
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
18
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
Meter Mains400 Amp | 4 & 5 Terminal | Ringless
400 AMPMETER MAINS
U6227-X-400-K3L U6230-X-400-K7
Catalog Number Terminals HubConnectors CU/AL Dimensions Knockouts
Line D” W” H” 1 2 3 4
U6227-X-400-K3L 4 C.P. #4-600kcmil or (2) 1/0 - 250 6 361⁄4 34 4 21⁄2 1⁄2 1⁄4
U6228-X-400-K3L 4 C.P. #4-600kcmil or (2) 1/0 - 250 6 361⁄4 34 4 21⁄2 1⁄2 1⁄4
U6227-X-400-K3L-5T6 5 C.P. #4-600kcmil or (2) 1/0 - 250 6 361⁄4 34 4 21⁄2 1⁄2 1⁄4
U6227-X-400-K3L-5T9 5 C.P. #4-600kcmil or (2) 1/0 - 250 6 361⁄4 34 4 21⁄2 1⁄2 1⁄4
U6228-X-400-K3L-5T6 5 C.P. #4-600kcmil or (2) 1/0 - 250 6 361⁄4 34 4 21⁄2 1⁄2 1⁄4
U6228-X-400-K3L-5T9 5 C.P. #4-600kcmil or (2) 1/0 - 250 6 361⁄4 34 4 21⁄2 1⁄2 1⁄4
400 Amp Meter Main | 4 & 5 Terminal | 1Ø3W | OH/UG | 240 VAC
Catalog Number HubConnectors CU/AL Dimensions Knockouts
Line D” W” H” 1 2 3 4
U6229-X-400-K7L C.P. #4-600kcmil or (2) 1/0 - 250 6 361⁄4 34 4 21⁄2 1⁄2 1⁄4
U6230-X-400-K7L C.P. #4-600kcmil or (2) 1/0 - 250 6 361⁄4 34 4 21⁄2 1⁄2 1⁄4
400 Amp Meter Main | 7 Terminal | 3Ø4W | OH/UG | 480 VAC
Specifications
• Side Buss Units: U6230• AIC Rating: 22K AIC at 240V; and 10K AIC at 480V.• 300 Amp breaker: Can be installed from the factory (upon request).
Specifications
• Side Buss Unit: U6228• AIC Rating : 22K AIC at 240V• 300 Amp breaker: Can be installed from the factory (upon request)
1 2 2 2
34
1 6227622862296230
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
19
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
Meter Mains400 Amp | 7 Terminal | Ringless
Catalog Number HubConnectors CU/AL Dimensions Knockouts
Line D” W” H” 1 2 3 4
U6115-X-2/200-K7L C.P. #4-600kcmil or (2) 1/0 - 250 7 341⁄4 34 1⁄2, 3⁄4 1⁄2, 3⁄4 1⁄2, 3⁄4 1⁄2, 3⁄4
400 Amp Meter Main with Breakers | 7 Terminal | 3Ø4W | Ringless | 480 VAC
Specifications
• U6115-X-2/200-K7L comes with (2) 200A 3Ø breakers
61151 1 2 2 2
34U6115-X-2/200-K7L
400 AMPMETER MAINS
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
20
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
Cold Sequence Meter Mains200-400 Amp | 4, 5 & 7 Terminal | Ringless
COLDSEQUENCE
METER MAINS
200 Amp Circuit Breaker Disconnect Ahead Of Meter Socket | Lever Bypass
400 Amp (320 Amp Continuous) Circuit Breaker Disconnect Ahead Of Meter Socket | Lever Bypass
Notes
• Hubs: For proper hub selection, refer to the hub suffix chart on the accessories page.
Catalog Number Terminals Service HubConnectors
CU/AL - LoadPhase
Dimensions Knockouts
D" W" H" 1 2 3 4
U5764-X-200-CB 4 OH/UG C.P. #6-350 1Ø3W 427⁄32 13 43 4 21⁄2 1⁄4 —
U5784-O-200-CB 4 UG Blank #6-350 1Ø3W or 3Ø3W 427⁄32 26 28 4 21⁄2 1⁄4 —
U5765-X-200-CB 5 OH/UG C.P. #6-350 1Ø3W or 3Ø3W 427⁄32 13 43 4 21⁄2 1 1⁄2 , 3⁄4
U5767-X-200-CB 7 OH/UG C.P. #6-350 3Ø4W 427⁄32 13 43 4 21⁄2 1 1⁄2 , 3⁄4
U5787-O-200-CB 7 UG Blank #6-350 3Ø4W 6 26 28 4 21⁄2 1 1⁄2 , 3⁄4
Catalog Number Terminals Service HubConnectors
CU/AL - LoadPhase
Dimensions Knockouts
D" W" H" 1 2 3 4
U5797-O-400-CB 4 UG Blank 3/0-500 1Ø3W or 3Ø3W 6 26 36 4 21⁄2 1 1⁄2 , 3⁄4
U5796-X-400-CB 7 OH/UG C.P. 3/0-500 3Ø4W 6 13 56 4 21⁄2 1⁄4 —
U5799-O-400-CB 7 UG Blank 3/0-500 3Ø4W 6 26 36 4 21⁄2 1 1⁄2 , 3⁄4
U5767-X-200-CB U5787-O-200-CB
1
1 1 123
1
57645765
5767
1
23 344
2 2 21 1
1 1
57845787
1
12 234
1
5796
57975799
1
12 2 2 2343
1
1 1
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
21
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
150 AMPMULTI-
POSITION
Multi-Position Sockets150 Amp | 4 Terminal | Ringless | 300 VAC
Catalog Number Positions Service HubConnectors CU/AL Dimensions Knockouts
Line Load D" W" H" 1 2 3 4 5
U1232-RRL-KK-K1 2 OH/UG H.O. #6-350 #6-350 51⁄8 261⁄2 14 3 21⁄2 1 1⁄2 1⁄4
U1233-RRL-KK-K1 3 OH/UG H.O. #6-350 #6-350 51⁄8 343⁄4 14 3 21⁄2 1 1⁄2 1⁄4
U1234-RXL-KK-K1 4 OH/UG C.P. #6-350 #6-350 51⁄8 427⁄8 16 3 21⁄2 1 1⁄2 1⁄4
150 Amp per Position | 4 Terminal | Multi-Position | Ringless | Horn Bypass
Notes
• Hubs: For proper hub selection, refer to the hub suffix chart on the accessories page. For the U1254-6 two hub openings are supplied and the extra opening is closed with a closing plate as standard.• Fifth Terminal: For field mounted fifth terminal, order catalog number K5T (9 o’clock position).
12 4
4 4
53
2 2 2 2
2 2
12 234 5 4
2 22
U1232-RRL-KK-K11232
123312 2 3 25 2
22222
4 4 4 411234
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
22
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
Multi-Position Sockets200 Amp | 4 Terminal | Ringless | 300 VAC
200 AMPMULTI-
POSITION
200 Amp per Position | 4 Terminal | Multi-Position | Ringless | Horn Bypass
Notes
• Hubs: For proper hub selection, refer to the hub suffix chart on the accessories page. For the U1254-6 two hub openings are supplied and the extra opening is closed with a closing plate as standard.• Fifth Terminal: For field mounted fifth terminal, order catalog number K5T (9 o’clock position).• Product numbers with BLG are used in AEP service areas.
Catalog Number Positions Service HubConnectors CU/AL Dimensions
Line Load D" W" H"
U1252-RRL-KK-K1-SLVG 2 OH/UG H.O. #6-350 #6-350 51⁄8 261⁄2 14
U1252-RRL-KK-K1-BLG-SLVG 2 OH/UG H.O. #6-350 #6-350 51⁄8 261⁄2 14
U1253-RRL-KK-K1-SLVG 3 OH/UG H.O. #6-350 #6-350 51⁄8 343⁄4 14
U1253-RRL-KK-K1-BLG-SLVG 3 OH/UG H.O. #6-350 #6-350 51⁄8 343⁄4 14
U1254-RXL-KK-K1-SLVG 4 OH/UG C.P. #6-350 #6-350 51⁄8 427⁄8 16
U1254-RXL-KK-K1-BLG-SLVG 4 OH/UG H.O. #6-350 #6-350 51⁄8 427⁄8 16
U1255-RXL-KK-K1-SLVG 5 OH/UG C.P. #6-350 #6-350 51⁄8 541⁄2 16
U1255-RXL-KK-K1-BLG-SLVG 5 OH/UG H.O. #6-350 #6-350 51⁄8 541⁄2 16
U1256-RXL-KK-K1-SLVG 6 OH/UG C.P. #6-350 #6-350 51⁄8 631⁄16 18
U1256-RXL-KK-K1-BLG-SLVG 6 OH/UG H.O. #6-350 #6-350 51⁄8 631⁄16 18
U1252-RRL-KK-K1-SLVG
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
23
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
Multi-Position SocketsKnockout information
KNOCKOUT INFORMATION
Knockouts
1 2 3 4 5
3 21⁄2 1 1⁄2 1⁄4
1222
2 2 2 2
2 2 2
2 2 2
134 45 4 4441 12 2 2 2 2
2 22222
34 4 4 45 4
12 4
4 4
53
2 2 2 2
2 2
12 234 5 4
2 22
1252
125312 2 3 25 2
22222
4 4 4 411254
1255 1256
4
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
24
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
200 AMPLEVER BYPASS
MULTI-POSITION
Lever Bypass Multi-Position Sockets200 Amp | 5 Terminal | Ringless | 600 VAC
Catalog Number Positions Service HubConnectors CU/AL
BypassDimensions Knockouts
Line Load D" W" H" 1 2 3
U2872-XT 2 OH/UG (2) C.P. 3⁄8" x 16 Stud #6-350 Lever 6 321⁄8 251⁄4 4 21⁄2 1⁄4,1⁄2
U2873-XT 3 OH/UG (2) C.P. 3⁄8" x 16 Stud #6-350 Lever 6 423⁄16 251⁄4 4 21⁄2 1⁄4,1⁄2
U2874-XT 4 OH/UG (2) C.P. 3⁄8" x 16 Stud #6-350 Lever 6 521⁄4 251⁄4 4 21⁄2 1⁄4,1⁄2
U2875-XT 5 OH/UG (2) C.P. 3⁄8" x 16 Stud #6-350 Lever 6 625⁄16 251⁄4 4 21⁄2 1⁄4,1⁄2
U2876-XT 6 OH/UG (2) C.P. 3⁄8" x 16 Stud #6-350 Lever 6 723⁄8 311⁄4 4 21⁄2 1⁄4,1⁄2
200 Amp per Position | 5 Terminal | Multi-Position | Ringless
Notes
• Hubs: Units supplied with two closing plates. To order hubs as extra, refer to the hub suffix chart on the accessories page.• Connector Kits: For line side connector kits, order as extra K1539 (350 kcmil), K1540 (600 kcmil), twin K1350 (350 kcmil), twin K1541 (600 kcmil). Line connectors can be reversed to change from “OH” to “UG” service. For line side connector lug kits, order as extra from chart on the accessories page.• Bypass: Lever supplies clamping action on meter spades and also operates bypass device.
2 2 2 2
2 2 21 1 3 2
2
2
2 231 1
2 2
2872
2873 2874
U2873-XT
2 2
21 1 3 22
2 2
2 2 2 2 2
2 2 1 1 3 2 2 2
2 2 2
1 1 3
2 2 2 2 2
2 2 2 2 2 22875 2876
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
25
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
Lever Bypass Multi-Position Sockets200 Amp | 7 Terminal | Ringless | 600 VAC 3 phase
200 AMPLEVER BYPASS
MULTI-POSITION
200 Amp per Position | 7 Terminal | Multi-Position | Lever Bypass | Ringless
Notes
• Hubs: Units supplied with two closing plates. To order hubs as extra, refer to the hub suffix chart on the accessories page.• Connector Kits: For line side connector kits, order as extra K3082 (350 kcmil), K3441 (600 kcmil), twin K3442 (350 kcmil), twin K3083 (600 kcmil). Line connectors can be reversed to change from “OH” to “UG” service.• Bypass: Lever supplies clamping action on meter spades and also operates bypass device.
Catalog Number Positions Service HubConnectors CU/AL Dimensions Knockouts
Line Load D" W" H" 1 2 3
U2732-XT 2 OH/UG (2) C.P. 3⁄8" x 16 Stud #6-350 6 321⁄8 251⁄4 4 21⁄2 1⁄4,1⁄2
U2733-XT 3 OH/UG (2) C.P. 3⁄8" x 16 Stud #6-350 6 423⁄16 251⁄4 4 21⁄2 1⁄4,1⁄2
U2734-XT 4 OH/UG (2) C.P. 3⁄8" x 16 Stud #6-350 6 521⁄4 251⁄4 4 21⁄2 1⁄4,1⁄2
U2735-XT 5 OH/UG (2) C.P. 3⁄8" x 16 Stud #6-350 6 625⁄16 251⁄4 4 21⁄2 1⁄4,1⁄2
U2736-XT 6 OH/UG (2) C.P. 3⁄8" x 16 Stud #6-350 6 723⁄8 311⁄4 4 21⁄2 1⁄4,1⁄2
2 2 2 2
2 2 21 1 3 2
2
2
2 231 1
2 2
U2732-XT
2732
2733 2734
2 2
21 1 3 22
2 2
2 2 2 2 2
2 2 1 1 3 2 2 2
2 2 2
1 1 3
2 2 2 2 2
2 2 2 2 2 22735 2736
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
26
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
125 & 200 AMPMULTI-
POSITIONMETER MAINS
Multi-Position Meter Mains125-200 Amp/Position | 4 Terminal | Ringless | 120/240 VAC
10K AIC
Catalog NumberAmps Per Position
Positions Main Bus Rating Line Connector SizeDimensions
D" W" H"
U2852-X 125 2 200 Amp 3⁄8" x 16 Stud* 513⁄16 18 25
U2853-X 125 3 200 Amp 3⁄8" x 16 Stud* 513⁄16 18 37
U2854-X 125 4 400 Amp 3⁄8" x 16 Stud* 47⁄8 31 25
U2855-X 125 5 400 Amp 3⁄8" x 16 Stud* 47⁄8 31 37
U2856-X 125 6 400 Amp 3⁄8" x 16 Stud* 47⁄8 31 37
Catalog NumberAmps Per Position
Positions Main Bus Rating Line Connector SizeDimensions
D" W" H"
U2862-X 200 2 250 Amp 3⁄8" x 16 Stud* 513⁄16 21 29
U2863-X 200 3 300 Amp 3⁄8" x 16 Stud* 513⁄16 21 41
U2864-X 200 4 400 Amp 3⁄8" x 16 Stud* 47⁄8 36 29
U2865-X 200 5 600 Amp 3⁄8" x 16 Stud* 47⁄8 36 41
U2866-X 200 6 600 Amp 3⁄8" x 16 Stud* 47⁄8 36 41
Size Suffix Kit Number Compatible With Wire Range
Single-K1 K1539 U2852-56, U2862-66 #6-350
-K3 K1540 U2854-56, U2864-66 #4-600
Twin-K2 K1350 U2854-56, U2863-66 #6-350
-K4 K1541 U2864-66 #2-600
Manufacturer 150-200 Amps 125 Amps or Less
Milbank WBJ —
Cutler Hammer BR, BJ Quicklag P, BR, HQP
Siemens QNR QP
Siemens/Murray MD MP
G.E. Q Line Q Line
Square D — Homeline
125 Amp per Position | Multi-Position Sockets | 10K AIC | Ringless
200 Amp per Position | Multi-Position Sockets | 10K AIC | Ringless
Connector Kits Breaker Chart
Notes
• Connectors: For line wire connector kits, order separately.• Fifth Terminal: For field mounted fifth terminal, order catalog number K2381. Order one per meter position.• Breakers: Units have provision for one double pole main per meter position. Breakers not included.• Short Circuit Current Rating: 10K AIC. However, this rating is limited to the lowest interrupting capacity of any circuit breaker installed. Watthour meter not included in short circuit current rating.• Knockouts: See next page for drawings and knockout configurations.* To add lugs, see the Connector Kits chart.
U2866-XU2854-X
(Order circuit breakers separately)
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
27
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
Multi-Position Meter MainsKnockout Information
125/200 AMPMULTI-
POSITIONMETER MAINS
Catalog NumberKnockouts
1 2 3
U2852-X 3 11⁄4 1⁄4,1⁄2
U2853-X 3 11⁄4 1⁄4,1⁄2
U2854-X 3 11⁄4 1⁄4,1⁄2
U2855-X 3 11⁄4 1⁄4,1⁄2
U2856-X 3 11⁄4 1⁄4,1⁄2
U2862-X 3 2 1⁄4,1⁄2
U2863-X 3 2 1⁄4,1⁄2
U2864-X 3 2 1⁄4,1⁄2
U2865-X 3 2 1⁄4,1⁄2
U2866-X 3 2 1⁄4,1⁄2
1 1 23 2 22 2 2
12
322 222
12
322 222
213
22 222
13222
1
2
2223
2
28522862
28532863
2854
2864
2855 2856
1 1 23 2 22 2 2 1 1 23 2 22 2 22865 2866
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
28
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
125-200 AMPMULTI-
POSITIONMETER MAINS
Multi-Position Meter Mains125-200 Amp | 4 Terminal | Ringless | 120/240 VAC | 22K AIC
Catalog Number Amps Positions Service HubConnectors CU/AL
BypassDimensions Weight
(lbs.)Line D" W" H"
U5902-X-KK-BLG 125 2 OH/UG C.P. 3⁄8" x 16 Stud Horn 51⁄8 261⁄2 30 58
U5903-X-KK-BLG 125 3 OH/UG C.P. 3⁄8" x 16 Stud Horn 51⁄8 345⁄9 30 88
U5904-X-KK-BLG 125 4 OH/UG C.P. 3⁄8" x 16 Stud Horn 51⁄8 424⁄5 30 107
U5905-X-KK-BLG 125 5 OH/UG C.P. 3⁄8" x 16 Stud Horn 51⁄8 511⁄20 30 128
U5906-X-KK-BLG 125 6 OH/UG C.P. 3⁄8" x 16 Stud Horn 51⁄8 593⁄10 30 146
Catalog Number Amps Positions Service HubConnectors CU/AL
BypassDimensions Weight
(lbs.)Line D" W" H"
U5882-X-KK-BLG 200 2 OH/UG C.P. 3⁄8" x 16 Stud Horn 51⁄8 261⁄2 30 58
U5883-X-KK-BLG 200 3 OH/UG C.P. 3⁄8" x 16 Stud Horn 51⁄8 345⁄9 30 88
U5884-X-KK-BLG 200 4 OH/UG C.P. 3⁄8" x 16 Stud Horn 51⁄8 424⁄5 30 107
U5885-X-KK-BLG 200 5 OH/UG C.P. 3⁄8" x 16 Stud Horn 51⁄8 511⁄20 30 128
U5886-X-KK-BLG 200 6 OH/UG C.P. 3⁄8" x 16 Stud Horn 51⁄8 593⁄10 30 146
125 Amp per Position | 4 Terminal | Multi-Position Meter Main | Ringless
200 Amp per Position | 4 Terminal | Multi Position Meter Main | Ringless
Notes
• Knockouts: See drawings on the next page.• Optional: Factory installed breakers are available - consult factory.• AIC Rating: All models are rated 22K AIC when used with approved breakers rated at 22K.• Hub: Units supplied with one (1) closing plate. Order hubs separately, see accesory page.• Fifth Terminal: For field installed fifth terminal, order K5T.• Connectors: Socket is supplied with 3⁄8" - 16 hex head nuts with Belleville washers. For connector lug kits, order as extra
from chart on the accessories page. Separate lug kits are required for line and load.
U5882-X-KK-BLG U5884-X-KK-BLG
Rating kAIC
Circuit Breaker125A
10
SIEMENS: QPCUTLER-HAMMER: BR, HQP, QHP,QPGF
SQUARE D: HOMELINE.G.E.: (50AMP.MAX.) THQL, THQL-GF
22 SIEMENS: QPH
150-200 AMP
10 SIEMENS: QN
22 SIEMENS: QNH
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
29
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
Multi-Position Meter MainsDimensional Information
125/200 AMPMULTI-
POSITIONMETER MAINS
Knockouts
1 2 3 4 5
3 21⁄2 1 7⁄8 1⁄4
1 34 45 22
2 2
30
26.5
5.13
12 3 22 1
30
5.13
34.6
1 12 2 2 2 23
30
51.1
5.13
1 12 2 2 2 2 23
30
59.3
5.13
1 3 1 222 2
30
42.8
5.13
58825902
58835903
58845904
58855905
58865906
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
30
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
Catalog Number Terminals Type Hub Meter Form Connectors CUDimensions Knockouts
D" W" H" 1 2 3 4
UC1299-RL 6 Ringless H.O. 4S #14-#4 MAX 35⁄16 8 14 2 11⁄2 11⁄4 1⁄4
UC7235-RL 8 Ringless H.O. 5S #14-#4 MAX 35⁄16 8 14 2 11⁄2 11⁄4 1⁄4
UC7237-XL 13 Ringless C.P. 6, 8, 9 #14-#4 MAX 35⁄16 8 14 2 11⁄2 11⁄4 1⁄4
Catalog Number Terminals Type Hub Meter Form Connectors CUDimensions Knockouts
D" W" H" 1 2 3 4
UC1300-RL 6 Ring Type H.O. 4S #14-#4 MAX 35⁄16 8 14 2 11⁄2 11⁄4 1⁄4
Transformer Rated20 Amp | Plunger Bypass | Ringless & Ring Type
1 Piece Cover | Overhead / Underground | Ringless
1 Piece Cover | Overhead / Underground | Ring Type
UC7235
2
1
4
33
2
130072357237
20 AMPTRANSFORMER
RATED
Notes
• Hubs: For proper hub selection see the hub suffix chart on the accessory page.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
31
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
20 AMPTRANSFORMER
RATED
Transformer Rated20 Amp | Test Switch Provision
Catalog Number Terminals Hub Meter Form Connectors CU BypassDimensions Knockouts
D" W" H" 1 2
UC7478-RL 6 H.O. 4S #14 - #4 Max None 41⁄8 12 20 11⁄4 1⁄4, 1⁄2
UC7444-RL 8 H.O. 5S #14 - #4 Max None 41⁄8 12 20 11⁄4 1⁄4, 1⁄2
UC7445-RL 13 H.O. 6, 8, 9 #14 - #4 Max None 41⁄8 12 20 11⁄4 1⁄4, 1⁄2
UC7445-RL-641* 13 H.O. 6, 8, 9 #14 - #4 Max None 41⁄8 12 20 11⁄4 1⁄4, 1⁄2
UC7445-WL 13 1 in 6, 8, 9 #14 - #4 Max None 41⁄8 12 20 11⁄4 1⁄4, 1⁄2
RinglessCatalog Number
Ring TypeCatalog Number
Terminals Meter Form Hub Connectors CUDimensions Knockouts
D" W" H" 1 2
UC7532-RL UC7636-RL 6 4S H.O. #14 - #4 Max 41⁄8 12 20 11⁄4 1⁄4, 1⁄2
UC7448-RL UC7460-RL 8 5S H.O. #14 - #4 Max 41⁄8 12 20 11⁄4 1⁄4, 1⁄2
UC7449-RL UC7461-RL 13 6, 8, 9 H.O. #14 - #4 Max 41⁄8 12 20 11⁄4 1⁄4, 1⁄2
1 Piece Cover | Ringless | Overhead / Underground | with test switch provision
2 Piece Cover | Ringless | Overhead / Underground | with test switch provision
Notes
• Hubs: For proper hub selection see the hub suffix chart on the accessory page.• Sealing Rings: Ring type units are supplied with one MR-2, snap type, sealing ring.• Pre-wiring: Factory pre-wiring available.• Connectors: Units are supplied with mechanical type connectors (#4 max). If compression type connectors (#10) are preferred, change catalog prefix to “S” (i.e, UC7445-XL becomes S7445-XL). The “S” prefix also designates non-U/L.
*Pre-wired per Lebanon specifications
1 1
1 211744474457478
1 1
1 211746074617636
UC7449-XL UC7532-RLUC7478-RL
744874497532
1 1
1 211
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
32
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
Lever Bypass Transformer Rated80 Amp | 6, 8 & 13 Terminal
80 AMPTRANSFORMER
RATED
80 Amp | Ringless | Transformer Rated | Lever Bypass | No Test Switch Provision
Notes
• Hubs: For proper hub selection see the hub suffix chart on the accessory page.• Bypass: Lever operates current bypass device and also supplies clamping action on current meter spades.• Connectors: Units are supplied with mechanical type connectors (#4 max).
Catalog Number
Terminals Service Hub Meter Form Connectors CUDimensions Knockouts
D" W" H" 1 2 3 4 5
U4490-XL 6 OH/UG C.P. 4S #14 - #4 Max 47⁄8 10 181⁄2 3 11⁄2 1⁄2,3⁄4 3⁄4 1⁄4
U4492-XL 8 OH/UG C.P. 5S #14 - #4 Max 47⁄8 10 181⁄2 3 11⁄2 1⁄2,3⁄4 3⁄4 1⁄4
U4493-XL 13 OH/UG C.P. 6, 8, 9 #14 - #4 Max 47⁄8 10 181⁄2 3 11⁄2 1⁄2,3⁄4 3⁄4 1⁄4
U4490-XL
1 2
2 23
4
5
44904492
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
33
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
TESTSWITCHES
Test Switches4, 7 & 10 Pole
7 1/2"
3 1/2"
3 1/2"
9 1/2"
KeyP Potential Switch
C+ Line side current switch with short circuit assembly
C Load side current switch with test jack assembly
N Neutral bar (no switch)
Pn Neutral Potential Switch
X Unused Position on base
Insulating barrier, isolates both sides of switch
Catalog Number 7-Pole on a 10-Pole Base
TS07-0049 P X P X Pn X C+ C C C+
TS07-0018 P X P X Pn X C+ C C+ C
TS07-0059 X P C+ C P C C+ Pn X X
TS07-0022 P X P X Pn X C C+ C C+
Catalog Number 10-Pole
TS10-0109 P P P Pn C+ C C+ C C+ C
TS10-0110 P C+ C P C+ C P C+ C Pn
TS10-0111 P P P Pn C C+ C C+ C C+
TS10-0112 C+ C C+ C C+ C P P P Pn
Catalog Number 7-Pole
TS07-0105 P P Pn C+ C C+ C
TS07-0106 P C+ C P C+ C Pn
TS07-0107 P P Pn C C+ C C+
TS07-0108 C+ C C+ C P P Pn
CatalogNumber 4-Pole
TS04-0101 X P Pn X C+ C X
TS04-0102 X P C+ C X Pn X
TS04-0103 X P Pn X C C+ X
TS04-0104 X C+ C X P Pn X
Notes
• 4-pole switches are also available on 10-pole bases. Contact Milbank for appropriate catalog numbers.
Notes
• 4-pole switches are also available on 10-pole bases. Contact Milbank for appropriate catalog numbers.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
34
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
Test Switch WorksheetElectronic version available at milbankworks.com
KeyP Potential Switch
C+ Line side current switch with short circuit assembly
C Load side current switch with test jack assembly
N Neutral bar (no switch)
Pn Neutral Potential Switch
X Unused Position on base
Insulating barrier (one side)
Insulating barrier (two sides)
4
7
10
Other ____
Yes | Clear ___ Black ___
No
7-Pole
10-Pole
Number of Poles Test Switch Cover (only available for 10-pole bases)
Base Size
q qq qq
qqq
Engineering Information: ______________________________________________________________________________
______________________________________________________________________________________________________
_______________________________________________________________________________________
Customer Name: _________________________________________________________________
Email: ___________________________________________________________________________
_________________________________________________________________________________
Phone: _________________________________________________________________________
Custom Pole Arrangements: The key may be used to diagram your own pole arrangement. Be sure to specify base size and whether all C+ line side, current switch/shunt circuit assemblies are to be bussed together. The catalog numbers shown above are connected in line-load pairs; therefore, if bussed is required, different catalog numbers will apply.
TEST SWITCH BASEThe base is molded from a high strength, fiberglass reinforced, thermoset polyester. This material is track-resistant, flame-retardant and has low water absorption qualities. Bases are available in two standard sizes following NEMA mounting classifications.
Handle Color KeyBK Black P Purple Y Yellow GN Green
R Red BL Blue W White BKS Black Stripe
BR Brown GR Grey O Orange WS White Stripe
1 2 3 4 5 6 7 8 9 10
Pole Position Chart
Feature 1 2 3 4 5 6 7 8 9 1045° Angle Stops
Ganged Handles (C)
Bussing
Colored Handles
Special Features
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
TEST SWITCHWORKSHEET
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
35Current Transformer CabinetPanel Enclosure | Type 3R
CURRENT TRANSFORMER
CABINET
Outdoor Transformer Cabinets | NEMA 3R
Notes
• Features: Supplied with solid back board when noted, three point locking handle, lift off hinges with stainless steel pins and padlock provisions.
• U5990-O: is 3Ø with a 50K RMS rating, and has a wire range of #4-600 kcmil• Units with U Prefix are UL listed.
Catalog NumberDimensions Gauge of
SteelBoard Size CT Mounting
Provisions# of Doors Latching Type
D" W" H" W" H"
U4408-O 14 40 40 12 40 40 Wood 2 3 point latch
U4410-O 12 32 24 14 28 20 Wood 1 Flip latch
S4019-O 10 32 24 14 24 16 Wood 2 3 point latch
S4020-O 10 36 32 14 28 24 Wood 2 3 point latch
S4399-O 10 24 18 14 16 10 Wood 2 3 point latch
S4400-O 10 44 30 14 36 22 Wood 2 3 point latch
304410-CTC3R 10 44 30 12 — — None 2 Hasp
243210-CTC3R 10 32 24 14 — — None 2 Hasp
363612-LC3R-SP-WB 12 36 36 14 33 33 Rails 1 Wing handle
484812-CT3R-WB 12 48 48 14 44 44 Rails 2 3 point latch
U5990-O 10 36 36 12 CT mounting rack included 2 3 point handle
304410-CTC3R U5990-O
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
36 Multi-Position Tap BoxThree Phase | Aluminum Construction | Wall or Pad Mountable
Catalog Number PhasePosition
LugsMaximumWire Size
MaximumAmperage
Dimensions
D" W" H"
UAP6094-O 3 16 500 kcmil 3000 Amps 16 255⁄8 43
UAP6095-O 3 22 500 kcmil 4000 Amps 16 323⁄8 43
UAP6096-O 3 14 750 kcmil 3300 Amps 16 2515⁄16 51
Features• Painted Aluminum Construction: Enclosure
shells are constructed with lightweight aluminum, making wall-mount installations easier. Powder-coat paint finish helps prevent corrosion.
• Capable of Wall or Pad Mounting: Units feature a removable bottom, allowing an easy conversion from a wall-mount to a pad-mount.
• Smaller Footprint: The UAP6094 model has a more compact footprint compared with the leading competitor.
• Multi-port ground lugs• Optional Pentabolt Secured Handle
available (see pics below): Enclosure handle can be included with an optional pentabolt locking mechanism (see photos below) for enhanced protection.
Common Applications
Strip Malls Housing DevelopmentsApartment Buildings
Stainless steel pad mount spacing brackets included
MULTI-POSITIONTAP BOX
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
37Multi-Position Tap BoxLine Drawings
6094
6096
25 5/8" O.D.
43"
3"
5 1/8"
7"
16" I.D.
32 3/8" O.D.
43"
3"
5 1/8"
7"
16" I.D.
25 15/16" O.D.
51"
3"
5 1/8"
7"
16" I.D.
LINE DRAWINGS
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
38
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
200 AMPMETER MAIN WITH
LOAD CENTER
PEDESTAL
Meter Main w/ Load Center Pedestal 100-200 Amp | 4 Terminal | Ringless | 120/240 VAC
Catalog NumberBreakerAmps
Service PowerheadsBranchCircuits
BypassConnectors CU/AL Knockouts
Line Load 1 2 3
U5136-O Provision UG Single 4 Horn #6-350 CB 2 1⁄2,3⁄4 1⁄4
U5136-O-100S 100 UG Single 4 Horn #6-350 CB 2 1⁄2,3⁄4 1⁄4
U5136-O-200S 200 UG Single 4 Horn #6-350 CB 2 1⁄2,3⁄4 1⁄4
U5137-O-200S 200 UG Double 4 Horn #6-350 CB 2 1⁄2,3⁄4 1⁄4
Catalog NumberBreakerAmps
Service PowerheadsBranchCircuits
BypassConnectors CU/AL Knockouts
Line Load 1 2 3
U6220-O-100-KK-10GR 100 UG Single 10 Horn #6-350 #6-350 2 1⁄2,3⁄4 1⁄4
U6220-O-200-KK-10GR 200 UG Single 8 Horn #6-350 #6-350 2 1⁄2,3⁄4 1⁄4
100-200 Amps | 4 Terminal | Meter Main Pedestal | Ringless
100-200 Amps | 4 Terminal | Meter Main Pedestal | Ringless
Notes
• Parallel to Series Conversion: For field converting from parallel wired to series wired order K5194.• Fifth Terminal: For field installed fifth terminal, order K5T.• Stabilizer Foot: For field installed stabilizer foot, order K5415.• Penta Bolt Locking: For field installed pedestal fronts penta bolt locking, order K5039.• Receptacles: Consult factory for installed receptacle assemblies.• Short Circuit Current Rating: 22K AIC. However, this rating is limited to the lowest interrupting capacity of any circuit breaker installed. Watthour meter not included in short circuit current rating.• Receptacle Bridge is ordered separately on part# K5400-BRIDGE-2POS.• Contact factory for receptacle configurations available.• Pedestals with -10GR suffix include a 20 amp GFI receptacle.
U5136-O-200S
24”
27.5”
50”
80”
Grade Level
1
1
2 2
3 3
1
1
9.875”4.13”
16.07”
51365137
U6220-O-20
Rating kAIC
Large Frame Main Breaker
Small Frame Branch Breakers
10 UQFP-M
SIEMENS: QP, QTCUTLER-HAMMER: QP, BD, BR;
G.E.: TQ, THQ, THQLSQUARE D: HOM115, HOM2100
22 UQFPH-M QPH
AIC Rating Amps Siemens Cutler Hammer General Electric Square D
10k150-200 QNR BR (150A only) — —
≤ 125 QP HQP, BR THQL, THQL-GF Homeline
22k150-200 QNRH — — —
≤ 125 QPH — — —
Breaker Chart U5136 & U5137
Breaker Chart U6220
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
39
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
DEVICE PLATES
Device PlatesU5136 & U5137
K5935-41 K5935-10GR K5935-11GR
K5935-36GR K5935-54 K5935-2/1450
K5400-BRIDGE-2POS
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
40
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
Temporary Power Units125 Amp | 4 Terminal | Ringless | 120/240 VAC
TEMPORARYPOWER
125 Amps | 4 Terminal | Temporary Power Units | Ringless | 1Ø3W
Notes
• Interior: Six circuit plated copper interior accepts standard plug-in type circuit breakers.• Receptacle Bridge: Three position self-grounded receptacle bridge accepts most standard NEMA receptacles with mounting plates.• Included Parts: U4908 and U5101 come supplied with 2-20 amp single pole breakers and 2-20 amp GFCI receptacles installed and pre-wired.
Catalog Number Service HubConnectors CU/AL Dimensions Knockouts
Line Load D" W" H" 1 2 3 4 5
U5101-XL-11GR OH C.P. #6-350 #6-350 53⁄16 87⁄8 25 2 11⁄2 11⁄4 1⁄4 —
U4908-O-11GR UG Blank #6-2/0 #6-2/0 53⁄16 9 2515⁄16 2 11⁄2 11⁄4 1⁄4 —
1
3
4 4
22
3
U4908-O-11GRU5101-XL-11GR
1
3
2
4 4
2 49085101
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
41
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
SURFACE MOUNT POWER
OUTLET
Surface Mount Power OutletMillennium Series | Metered & Unmetered | 120/240 VAC
Catalog Number
Metered/Unmetered
ReceptacleConfiguration
Circuit Breaker Configuration
LoopFeed
Connectors -Line
Dimensions Knockouts
D" W" H" 1 2 3
U5000-XL* Unmetered — — Yes (2) 1/0-#12 51⁄2 91⁄8 191⁄4 2 11⁄2 11⁄4
U5000-XL-41 Unmetered A X Yes (2) 1/0-#12 51⁄2 91⁄8 191⁄4 2 11⁄2 11⁄4
U5000-XL-55 Unmetered B Y Yes (2) 1/0-#12 51⁄2 91⁄8 191⁄4 2 11⁄2 11⁄4
U5000-XL-75 Unmetered C Z Yes (2) 1/0-#12 51⁄2 91⁄8 191⁄4 2 11⁄2 11⁄4
U5100-XL* Metered — — No #6-250 51⁄2 91⁄8 25 2 11⁄2 11⁄4
U5100-XL-41 Metered A X No #6-250 51⁄2 91⁄8 25 2 11⁄2 11⁄4
U5100-XL-55 Metered B Y No #6-250 51⁄2 91⁄8 25 2 11⁄2 11⁄4
U5100-XL-75 Metered C Z No #6-250 51⁄2 91⁄8 25 2 11⁄2 11⁄4
125 Amp | Surface Mount Power Outlets | Ring-Type
Receptacle Configurations
Circuit Breaker Configurations
1 22
3 3
5000
U5000-XL-75 U5100-XL-75
1
3 3
22
5100
NOTE
Contact factory for additional configurations not shown here.
A B C
(1) TT30R, (1) 5-20R GFI (1) 14-50R, (1) 5-20R GFI (1) 14-50R, (1) TT30R,(1) 5-20R GFI
X Y Z
(1) 30A, 1P, 120V(1) 20A, 1P, 120V
(1) 50A, 2P, 120/240V(1) 20A, 1P, 120V
(1) 50A, 2P, 120/240V(1) 30A, 1P, 120V(1) 20A, 1P, 120V
* Comes with circuit breaker bridge For easy read meter see the accessory pages for CL200 analog or CL200-D digital meter.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
42
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
Power Outlet PedestalsMillennium Series | Metered & Unmetered | 120/240 VAC
POWER OUTLETPEDESTALS
125 Amp | Power Outlet Pedestals | Direct Burial | Ring-Type
Catalog NumberDouble Head
Catalog NumberMetered/
UnmeteredReceptacle
ConfigurationCircuit Breaker Configuration
Dimensions Knockout
D" W" H" 1
U5200-XL* U5220-XL Unmetered — — 59⁄16 91⁄8 641⁄2 11⁄4
U5200-XL-41 U5220-XL-41 Unmetered A X 59⁄16 91⁄8 641⁄2 11⁄4
U5200-XL-55 U5220-XL-55 Unmetered B Y 59⁄16 91⁄8 641⁄2 11⁄4
U5200-XL-75 U5220-XL-75 Unmetered C Z 59⁄16 91⁄8 641⁄2 11⁄4
U5300-O* U5320-O Metered — — 59⁄16 91⁄8 701⁄4 11⁄4
U5300-O-41 U5320-O-41 Metered A X 59⁄16 91⁄8 701⁄4 11⁄4
U5300-O-55 U5320-O-55 Metered B Y 59⁄16 91⁄8 701⁄4 11⁄4
U5300-O-75 U5320-O-75 Metered C Z 59⁄16 91⁄8 701⁄4 11⁄4
1 2 2
52005220
U5200-XL-75 U5300-O-75
1 2 2
53005320
Receptacle Configurations
Circuit Breaker Configurations
NOTE
Contact factory for additional configurations not shown here.
Pad mount is available - contact factory for information.
A B C
(1) TT30R, (1) 5-20R GFI
(1) 14-50R, (1) 5-20R GFI
(1) 14-50R, (1) TT30R, (1) 5-20R GFI
X Y Z
(1) 30A, 1P, 120V(1) 20A, 1P, 120V
(1) 50A, 2P, 120/240V(1) 20A, 1P, 120V
(1) 50A, 2P, 120/240V(1) 30A, 1P, 120V(1) 20A, 1P, 120V
*Circuit Breaker Bridge included
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
43
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
CIRCUITBREAKERS
Circuit BreakersUQFP Plug-In & UQFB Bolt-On Series | 120/240 VAC
UQFPUQFPH
UQFP-MUQFPH-M
200 Amp Frame | Plug-In | 10,000 AIC & 22,000 AIC | Two-Pole - Common Trip
200 Amp Frame | Bolt-On | 10,000 AIC & 22,000 AIC | Two-Pole - Common Trip
Amps10K AIC Plug-In
22K AIC Plug-In
10K AICPlug-In
22K AICPlug-In
Wire Range
CU AL
100 UQFP-100 UQFPH-100 UQFP-M-100 UQFPH-M-100 #3-#1 #1-1/0
125 UQFP-125 UQFPH-125 UQFP-M-125 UQFPH-M-125 #3-#1 #1-1/0
150 UQFP-150 UQFPH-150 UQFP-M-150 UQFPH-M-150 1/0-300 2/0-300
175 UQFP-175 UQFPH-175 UQFP-M-175 UQFPH-M-175 1/0-300 2/0-300
200 UQFP-200 UQFPH-200 UQFP-M-200 UQFPH-M-200 1/0-300 2/0-300
Amps10K AICBolt-On
22K AICBolt-On
10K AICBolt-On
22K AICBolt-On
Wire Range
CU AL
100 UQFB-100 UQFBH-100 UQFB-100-X1 UQFBH-M-100 #3-#1 #1-1/0
125 UQFB-125 UQFBH-125 UQFB-125-X1 UQFBH-M-125 #3-#1 #1-1/0
150 UQFB-150 UQFBH-150 UQFB-150-X1 UQFBH-M-150 1/0-300 2/0-300
175 UQFB-175 UQFBH-175 UQFB-175-X1 UQFBH-M-175 1/0-300 2/0-300
200 UQFB-200 UQFBH-200 UQFB-200-X1 UQFBH-M-200 1/0-300 2/0-300
Notes
• UL Listed: For use with 60°C or 75°C wire.• UQFP: For parallel main circuit breaker applications.• UQFP-M: For series main circuit breaker applications Split load tab features allow for feed-through capability.• UQFB: (2) 1/0-300 lugs provided on load and line side (cable-in, cable-out).• UQFB3: Three-pole available. Consult factory.• UQFB-X: (2) 1/0-300 lugs provided on load side and (2) line bar bus connections on line side.• UQFB-M: For series main circuit breaker applications. Split load tab features allow for feed-through capability.
UQFB-X1 UQFBH
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
44
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
CIRCUITBREAKERS
Circuit BreakersQP (small frame) and QN (large frame) | 120/240 VAC
QN2200H
Q250WBJ2200
QN2200RH
15–125 Amp BreakerPlug-In Type | 1” Per Pole
Amps Poles10K AIC Plug-In
22K AIC Plug-In
15 Single Q115 Q115H
15 Double Q215 Q215H
20 Single Q120 Q120H
20 Double Q220 Q220H
25 Single Q125 Q125H
25 Double Q225 Q225H
30 Single Q130 Q130H
30 Double Q230 Q230H
35 Single Q135 Q135H
35 Double Q235 Q235H
40 Single Q140 Q140H
40 Double Q240 Q240H
50 Single Q150 Q150H
50 Double Q250 Q250H
60 Single Q160 Q160H
60 Double Q260 Q260H
70 Single Q170 Q170H
70 Double Q270 Q270H
80 Double Q280 Q280H
90 Double Q290 Q290H
100 Double Q2100 Q2100H
125 Double Q2125 Q2125H
• Load connectors supplied with breakers.• UL Listed for use with 60°C or 75°C wire.• Wire sizes shown are lug capacity. Consult NEC Article #310 for specific wire sizes.
Notes
200 Amp Frame | Plug-In | 10,000 AIC & 22,000 AIC | Two-Pole, Common Trip
Amps 10K AIC Plug-In 22K AIC Plug-In Handle LocationWire Range
CU AL
150 QN2150 QN2150H Left facing #4-300 #4-300
200 QN2200 QN2200H Left facing #4-300 #4-300
150 QN2150R QN2150RH Right facing #4-300 #4-300
200 QN2200R QN2200RH Right facing #4-300 #4-300
150 WBJ2150 — Centered #2-300 #2-300
200 WBJ2200 — Centered #2-300 #2-300
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
45
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
AccessoriesHubs and Closing Plates
ACCESSORIES
-R
Large hub opening
-WL A7514 -YL A7515 -ZL A7516 -DL A7517 -EL A7518 -XL A7551
1" hub 11⁄4" hub 11⁄2" hub 2" hub 21⁄2" hub Small closing plate
-F A8110 -G A8111 -H A8112 -X A9064 -RRL S8324 -RXL S8324 A7551
3" hub 31⁄2" hub 4" hub Large closing plate Large hub open-ing adapted to
small hub open-ing
Large Hub opening adapted to small
closing plate
-RL
Small hub opening
Notes
• Suffix: Add to catalog number for factory installation of hub.• Packaging: Individually packed units for field installation.• Abbreviations: H.O. (hub opening), C.P. (closing plate).• Hub Mast rated
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
46
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
AccessoriesConnector Kits, Closing Kits & Generator Interlock
ACCESSORIES
Connector Kits — For Use with 3⁄8"-16 Stud Type Units Only
Closing Covers
Pole Hanger Kit850 comes with 4 pole hangers
Single Twin
Suffix Part # (3 per set) - 1Ø Suffix Part # (3 per set) - 1Ø
K1 K1539 6-350 K2 K1350 6-350
K3 K1540 4-600 or (2) 1/0-250* K2L K1350L 6-350 (non rotating)
K3L K1540L4-600 or (2) 1/0-250*
(non rotating) K4 K1541 4-600
Suffix Part # (4 per set) - 3Ø Suffix Part # (4 per set) - 3Ø
K5 K3082 6-350 K6 K3442 6-350
K7 K3441 4-600 or (2) 1/0-250* K8 K3083 4-600
Catalog Number
Description of pole hanger brackets
850Two pair (4 pieces)
with mounting hardware
Meter Closing Plate(Ring Type / Ring-
less)
Metal Closing Plate(For Ringless Sock-
ets)
6003 - Grey Plastic CP-21
6116 - Clear Plastic
6002 - Clear Plastic
K8180 (sold in pairs)
Bypass Link
K1047
A-GP
12 oz. spray can of grey paint
M5-144
Do not use with lever bypass sockets
Isolated Neutral Kit
ANSI-61-Grey
Disconnect Sleeve
Note
Consult factory for proper connector kits for studded meter sockets.
*For (2) 1/0-250, conductors must be of same size.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
47
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
AccessoriesFifth Terminals, Tap Connectors & Block Assemblies
ACCESSORIES
K1190 (For factory installed triplex ground, add suffix -TG to catalog number)
Fifth Terminals
Tap Connectors (3 per set)
100 Amp Blocks (single sockets only) 200 Amp Blocks (single sockets only)
5T8K2 - 100-200 Amp“Plug-In”
K5T - 200 Amp (Block with Square Hole)
K3865 - Heavy Duty Jaw Clamping (K3866 without Neutral Wire) K3356
Replaces the load or line side slide-in nut assembly on Milbank 200 amp sockets. Allows for a 100 amp tap location in addition to the #6-350 kcmil load-side connector. K5022 includes safety barrier extensions for applications over 300 VAC. Three lugs per kit.
K4977-INT - Internal Hex
K4977-EXT - External Hex
K5022-INT - Internal Hex (set of 4 w/ barrier) Wire Range #12 - 1/0
BL7474 - Block Assembly
Z904486-AO - Slotted Nut Assembly
Z802965-AC - Neutral without Nut
Z901925-AC - Hex Nut Set Screw
K4527 - Internal Hex Block Assembly (w/ meter support)
K4528 - External Hex Block Assembly (w/ meter support)
Z916265-AO - Internal Hex Slide Nut Assembly
Z916264-AO - External Hex Slide Nut Assembly
Z814898-AC - Neutral without Nut
Triplex Ground
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
48
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
COMMERCIALPEDESTALS
Commercial PedestalsAttractive | Easy to Install | Secure | Cost-Effective
Milbank Commercial Pedestals are pad-mounted, weatherproof electrical enclosures consisting of a utility pull section with optional meter socket, and a customer section containing distribution and control equipment. Milbank Commercial Pedestals are an attractive, secure, easy to install and cost-effective solution when underground remote site power distribution and control equipment is required, replacing unsightly and inefficient strut and backboard structures.
UL-listed as Industrial Control Equipment (File E113855)
Strut and backboard Commercial pedestal
• Type 3R rain resistant, vandal-resistant cabinet of polyurethane powder-coated steel (aluminum or stainless steel also available)• UL-listed as enclosed industrial control equipment (UL508)• Isolated lockable & sealable utility metering and lug landing sections• Lockable customer section for distribution and control equipment with internal deadfront• Print pocket inside customer section door contains wiring schematics and installation instructions• Most load centers are UL-listed for use with various manufacturers’ circuit breakers• All stainless steel external hardware (screws, bolts, hinges, handles, hasps and sealing screws)
Standard Features
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
49
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
COMMERCIALPEDESTALS
K3865Fifth terminal kit for use with ringless meter sockets
CP-ABK5/8Anchor bolt kit (includes four 5⁄8 - 13 x 18” anchor bolts
105JFifth terminal kit for use with ring-type meter sockets
CP-PE-HOA-3POSHOA switch for field installation
CP-TC7D 7-day time clock kitCP-TC24H24-hour time clock kitCP-TCWIREMale 4-pin connector and wiring harness for use with time clocks other than above
CP-16PDMNT-CALT 16" pedestal mounting baseCP-24PDMNT-CALT 24” pedestal mounting base (includes mounting hardware)
Commercial PedestalsAttractive | Easy to Install | Secure | Cost-Effective
Accessories
These units are ideal for controlling and metering:• Traffic signals• Street lighting• Power distribution for EV charging stations• Irrigation and sprinkler systems• Cell towers and telephone vaults• Pump stations• Temporary power for fairgrounds, swap meets, outdoor markets,
portable offices, holiday lights, etc.• Outdoor lighting for athletic fields, tennis and basketball courts,
parking lots, landscaping and subdivision entrances, etc.
• Meter sockets: ring type or ringless, up to 400 amp• Main and branch breakers or T fuses• Distribution: copper load centers and panel boards• Clocks, timers and relays• Photoelectric cells and controls• Power receptacles: pin and sleeve, twist lock or straight blade• Contactors: definite purpose, electrical or mechanically held, IEC
and mercury types• Surge protection and lightning arrestors• Reserve inlet generator receptacle with interlocked circuit breakers• Motor starters and relays• Push button controls• Thermostat controls, fans and heating strips• Power blocks and terminal blocks• Steel, aluminum and plywood backboards• Transformers• Interlock devices for circuit breakers• Available in steel, aluminum (raw painted or anodized) or stainless steel
construction with powder-coated finish available in eight standard colors or special-ordered RAL colors
• Available for applications up to 400 amp, 120V, 208V, 240V, 277V, 480V - 1Ø or 3Ø
Applications
Available Factory-Installed Options
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
50
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
Stocked Pedestals*Optional Fifth Terminal Kit
Main CB Load Center Circuits
Meter Socket Typeamp Spaces
CP3B51115A22 K3865 100 1,2 16 Ringless socket with lever bypassCP3B52119A22 K3865 200 1,2,3,4 24 Ringless socket with lever bypass
COMMERCIALPEDESTALS
Commercial PedestalsMain Load Center Series | Custom Designs Available
Notes
• Chart shows standard, stocked items. Other options and features are available. Contact factory for options, details and availability.
CP3B “ML” SeriesMain Load Center Series1Ø3 wire 120/240V or 208Y/120VApplication: remote site service for multiple loadsThe Milbank Main Load Center Commercial Pedestals are designed to handle the vast majority of all requirements in a standard, stocked configuration. • All units feature a load center with a plug-on, back-fed main breaker. • Load center has 16 positions for the 100 amp pedestals and 24 circuits for the 200 amp pedestals. • Both sizes include sub-feed lugs to allow feeding an external panel.
If your application requires turning loads on based on “dusk-to-dawn” requirements, be sure to see the Milbank Switched Load Center Commercial Pedestal products on the following page.
Typical Applications
Remote site service for multiple loads.
CP3B11115A22
Features
These units include everything required for remote site service:
• NEMA 3R construction.• Expandable: load centers allow for future expansion without costly
modifications.• All units feature 200 amp meter socket with optional field installable
fifth terminal kit available.• 22K amps interrupting capacity (AIC) standard.• Optional mounting base can be embedded in concrete for fast, easy
installation.• Separate sealable and lockable utility termination section.• Separate sealable and lockable metering section.• Separate sealable and lockable customer section with a load center
for “always on” loads that include a main circuit breaker, 20 (125 or 200 amp model) or 14 (100 amp model) blank breaker spaces and a circuit directory to document configuration.
Note
All meter form and bypass options
available to meet utility requirements.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
51
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
Stocked Pedestals*Optional Fifth Terminal Kit
Main CB Contactor amperage
Meter Socket Typeamp Spaces
CP3B51110A22SL1 K3865 100 1,3 60 Ringless socket with lever bypassCP3B52110A22SL1 K3865 200 1,2,3,4 100 Ringless socket with lever bypass
COMMERCIALPEDESTALS
Commercial PedestalsSwitched Load Center Series | Custom Designs Available
Notes
• Chart shows standard, stocked items. Other options and features are available. Contact factory for options, details and availability.
Typical Applications
Traffic signals, parking lots, highways & athletic
field lighting
CP3B11110A22SL1
CP3B “SL” SeriesSwitched Load Center Series1Ø3 wire 120/240V or 208Y/120V
Milbank’s Switched Load Center Commercial Pedestals are designed not only to provide power for various loads, but also to switch specific loads on and off under certain conditions. A photoelectric cell is used for these controlled loads, and an optional time clock is also available.
Features
These units include everything required for remote site service:
• NEMA 3R construction.• Expandable: load centers allow for future expansion without costly
modifications.• All units feature 200 amp meter socket with optional field installable fifth
terminal kit available.• 22K amps interrupting capacity (AIC) standard.• Optional mounting base can be embedded in concrete for fast, easy
installation.• Separate sealable and lockable utility termination section.• Separate sealable and lockable metering section.• Separate sealable and lockable customer section with a control circuit
including PE receptacle, Lexan® window, glare shield, Hand-Off-Auto (HOA) switch, contractor controlling a 16-circuit load center for controlled loads, a pre-mounted DIN rail and pre-wired connector to add an optional “plug-and-play” time clock kit for PE on and TC off operation and a circuit directory to document configuration.
• A load center for “always on” loads that includes a main circuit breaker, a control power circuit breaker, a switched load center main breaker, nine (125 or 200 amp model) or 11 (100 amp model) blank breaker spaces and a circuit directory to document configuration.
Note
All meter form and bypass options
available to meet utility requirements.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
52
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
Standard Pedestals*Optional fifth Terminal Kit
Main CB Load Center Circuits Meter Socket Type
CP3B54120B22 K3865 2-200 amp (2) 12 circuit1 Ringless with lever bypassCP3B5411JB22 K3865 320 amp (400 max) 0 Ringless with lever bypass
COMMERCIALPEDESTALS
Commercial Pedestals400 Amp Series
Milbank’s 400 Amp Commercial Pedestal is designed to provide a weather and vandal resistant metered enclosure for various loads and distribution. Each pedestal has been designed to handle a wide range of applications using standard, stocked configurations. • Choice of a single main breaker or twin service disconnect
breakers gives flexibility to the pedestal design. • Optional distribution with feed-thru lugs below the service
disconnect breakers allows the pedestal to handle numerous applications.
• Typical applications include remote homes where the metering is best located at the curb side or other remote area. The pedestal can also provide power to secondary residence, on-site business, workshop, irrigation, lighting, security or other secondary load.
• Available in custom colors to match home or landscaping.
Features
These units include everything required for remote service:• Type 3R construction• Main circuit breaker or dual service disconnects• Expandable: load center units allow for future expansion
without costly modifications• Optional mounting base can be embedded in concrete for
fast, easy installation• Separate sealable and lockable utility termination section
with lug termination• Separate sealable and lockable metering section • A separate sealable and lockable customer section with a
circuit directory and a print pocket to hold all documentation• Meter socket options include ring type with bypass studs,
ringless with heavy duty lever bypass, or K-Type bolt-on
Typical Applications
Remote site service for residential and commercial job sites.
CP3B1411JB22
Notes
• Chart shows standard, stocked items. Other options and features are available. Contact factory for options, details and availability.• Stud utility landing is standard. Lug kits are available from factory.
• Units with load centers have (2) #6-250 sub-feed lugs on each load center. (Each load center is 200 amp rated and UL Listed with: Siemens, General Electric and Cutler-Hammer plug-in style circuit breakers.)
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
53
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
Features
• 3Ø4W, 480Y/277 volt• One technician can install in under an hour with use of Milbank’s pre-drilled box pad• All units are UL listed and service entrance rated• Fused disconnect with accessible handle through the deadfront• HOA and push button start• Separate accessible utility side with pre-wired landing lugs• NEMA rated starters (sizes 1-5)• Soft start units sizes 30HP-150HP• 30 amp fuse block for pivot pre-wired in the unit• White powder coated paint finish helps keep components cooler • Options include: • Hour meter • Chemical injection receptacle • Multiple injection receptacle • Multiple 30A fuse blocks possible
COMMERCIALPEDESTALS
Commercial PedestalsCP3B “IR” Irrigation Control Series
Stocked Pedestals Exterior Cabinet NEMA Rating
CP3B0281UMWIR04 White 4CP3B0281UMWIR03 White 3CP3B0181UMWIR02 White 2
Notes
• Chart shows standard, stocked items. Other options and features are available. Contact factory for options, details and availability.
Milbank’s “IR” Series Irrigation Pedestals install quickly and simply – often in less than an hour with a single technician—a fraction of the time typically needed for strut farm and other installation set ups. Additionally, the pedestal comes pre-wired, so the technician simply drops in the pre-drilled concrete box pad, fastens the pedestal and runs the wires. Prewired landing lugs are provided in a separate utility side so that there is no more need to wrestle with hard-to-bend wires. Simply run the utility wire up and land on the lugs. With both the motor starter and disconnect in the same enclosure, all the controls are housed in a safe, lockable pedestal that protects against vandalism and energy theft.
Typical Applications
Power pedestal for irrigation systems or other pump control
applications.
CP3B0281UMWIR04
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
54
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
Commercial PedestalsCP3B “BBS” Battery Backup Series
COMMERCIALPEDESTALS
Milbank’s BBS Series Commercial Pedestals are designed to provide battery backup power for various loads, and to switch specific loads on and off under certain conditions; a photoelectric cell or time clock to control lighting circuits, as an example. Metered and non-metered power distribution options are available. The back-up power pedestal is designed to handle the vast majority of todays back-up power requirements. By using 19” rack design, shelves can be adjusted to accommodate the required batteries and manufactures DC to AC inverters, transfer switches and other related equipment. This design gives the user a wide range of design and configuration options. Complete turnkey, ready to power-up pedestals are offered along with basic units ready to accept batteries and inverters supplied by others.
Features
• Type 3R construction• 100 through 320 amp meter socket with the option of
either a ring type socket (conforms to EUSERC 308) with or without test/bypass blocks or a heavy duty ringless socket with lever bypass
• Separate sealable utility termination compartment• An isolated separate customer section with service
disconnects, power distribution options and power control • 19” wide rack in customer compartment for easy layout of
equipment• Battery trays• Thermostat with cooling fan• Filtered louvers for heat rise flow through ventilation• Three point door latch (key or pad lockable)
Options
• Manual bypass switch• Transfer switch for generator
power back-up• Generator inlet receptacles 30A
through 200A • Pad lockable provision for
receptacles• Police access door
• Metered load center distribution• Non metered load center
distribution• Photo electric controls (for street
lighting)• Time clocks• HOA switches• Contactors
• GFI duplex receptacles• Thermostat for heating control• Heating pads or elements• Roll out shelves for batteries• Surge arrestors and lighting
arrestors
Typical Applications
Metered emergency uninterrupted power for traffic intersections, wireless, phone and communications equipment, parking lots,
camera and security locations
CP3B5111TCAWSP1
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
55
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
COMMERCIALPEDESTALS
Commercial PedestalsCP3B “Power Transfer” Series
Typical Applications
Traffic intersections, cell sites, cable TV, pump and lift stations requiring utility power with backup generator power
Milbank’s Power Transfer Series Pedestals provide non metered AC power, distribution, surge suppression, mechanical interlock and stand-by generator receptacle— all in a neat, compact pedestal.
Features
• 120/240V 1Ø3W thru 277/480V 3Ø4W ratings• Metered or unmetered units• Choice of EUSERC ring type or ringless meter sockets• 60 amp thru 400 amp ratings • UL Listed Type 3R rated• Pad lockable, isolated utility compartments• 20 amp GFI convenience receptacle• Lockable recessed generator receptacle door • Utility and generator indicator light options• All stainless steel hardware• Galvanized steel, aluminum or stainless steel cabinet
options• Custom designs available
Typical Applications
Traffic intersections, cell sites, cable TV, pump and lift stations requiring utility power with
backup generator power
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
56
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
COMMERCIALPEDESTALS
Commercial PedestalsCP3BB “CT Metered” Series
Typical Applications
Large homes, pumping & lift stations, motor control, water treatment plants, EV charging stations, commercial buildings, large remote service
requirements, commercial and industrial control systems
Milbank’s CT Metered Series Commercial Pedestals are designed to be used where a smaller service package would be a better choice over large 3R rated combination switchboards. These pedestals have amperage ratings of 400 to 800 amps at voltages up through 480 volt three phase.
Features
• UL Listed, freestanding Type 3R service• A low profile CT pedestal• All utility equipment is isolated in separated pad
lockable and sealable compartments • Separate customer compartment designed to hold
distribution and control equipment• Dead front customer construction• Optional mounting base• Optional construction in steel, aluminum and stainless
steel.• Wide choice of powder paint colors
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
57
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
COMMERCIALPEDESTALS
Commercial Pedestals CP3A “Slimline” Series
Typical Applications
Roadway lighting and signage, wastewater
treatment facilities, parks and landscaping, and any application where physical
space is at a premium
Milbank’s Slimline Series Commercial Pedestals provide a sleeker, smaller footprint and wireway access on the side of the unit rather than the back, allowing maximum flexibility to place the pedestal in tighter spaces.
Features• UL Listed as service equipment• 100 or 200 amp• Vandal-resistant, secure and attractive design• Customer compartment with distribution and control equipment with
swing dead front door, secured with both a hasp/latch and draw latch outer door
• Utility metering compartment protected with a hinged hood, increasing resistance to meter vandalism
• Small footprint• Wireway located on left side of pedestal for utility incoming wire,
allowing pedestal to be mounted with back very close to a wall (14")• Available in 12" and 20" widths and 50" and 63" (metered) and 43"
(nonmetered) heights• Includes a print pocket for plans and drawings• 200 amp main available• Voltage range: 120V–480V• Compatible with both ringless and ring type meter sockets, 4–7
terminals• Available in a wide array of colors, including but not limited too all ANSI
powder coated paint colors upon request• Pedestal mounting base option saves time and labor to install on a
cement pad—no anchor bolts required• Powder-coated G90 galvanized steel, raw, anodized or powder-coated
aluminum and stainless steel exterior options
“Slimline” Series Direct Bury Extension• No need for concrete• Bolts directly to unit• Easy, modular design• Ships in a smaller package• Increases project flexibility• Easier to handle and install• Utilizes a stabilizer foot to prevent leaning over time• Pedestal and extension can be installed within 30 minutes
Notes
• Currently only built in 14 guage steel• Only available for 12” pedestals
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
58
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
Watthour Meter FormsStandard Forms | Transformer Rated or Self-Contained
WATTHOURMETER FORMS
SC SC TR TR TR
TR SC SC SC SC
TR TR SC SC TR
TR TR SC SC TR
TR TR TR
2 and 3-WIRE FORMS1S & 2S
2 and 3-WIRE FORMS1S & 2S with BYPASS
2-WIRE FORM 3S5th Term. 9 o’clock
2-WIRE FORM 3Swith BYPASS
2-WIRE FORM 3S5th Term. 6 o’clock
2-WIRE FORM 3Swith BYPASS
2 ELEMENT3-WIRE NETWORK
FORM 12S 5thTERM. 9 o’clock
2 ELEMENT 3-WIRENETWORK FORM 12S
with BYPASS5th Term. 9 o’clock
2 ELEMENT 3-WIRENETWORK FORM 12S
with BYPASS5th Term. 6 o’clock
2 ELEMENT3-WIRE NETWORK
FORM 12S 5thTERM. 6 o’clock
3-WIRE FORM 4S 3-WIRE FORM 4SWITH BYPASS
2 or 3 ELEMENT3Ø4W Y or
Y FORM 14SFORM 15S
Y FORM 16S
2 or 3 ELEMENT3Ø4W Y or
FORMS 14S & 15Swith BYPASS
2 ELEMENT3Ø4W Y orY FORM 7SFORM 24S
with BYPASS
2 ELEMENT2Ø3W, 2Ø4W, 3Ø3W
FORM 5S
2 ELEMENT Ø3W,2Ø4W, 3Ø3W FORM 5S with
BYPASS
2 ELEMENT2Ø3W, 2Ø4W, 3Ø3W
FORM 13S
2 or 3 ELEMENT2Ø3W, 2Ø4W, 3Ø3W
FORM 13S withBYPASS
2 or 3 ELEMENT3Ø4W Y orY FORM 9SFORM 8S
2 or 3 ELEMENT3Ø4W Y or
FORMS 8S & 9SFORMS 8S & 9S
with BYPASS
2 ELEMENT3Ø4W YFORM 6S
2 ELEMENT3Ø4W YFORM 6S
with BYPASS
TR = TRANSFORMER RATEDSC = SELF CONTAINED
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
59
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
Meter FormsReference Information
METERFORMS
++
ILINE (BONDED)N
C.T.LOAD
2 ++
DIAGRAM D
P1 P2 C+1 C2C+
2PN C1
C.T.
DIAGRAM D1∅3W or 3W Network with 2 C.T.’s
2 Stator Meter - Form 5S8T Socket, Test Switch #TS07-0105
++
1LINE
C.T.LOAD2
P1 C+1
++
3
++
PT PT
DIAGRAM E
P3 P2 C1 C+3 C3
C.T.
DIAGRAM E3∅3W “∆” with 2 P.T.’s & 2 C.T.’s
2 Stator Meter - Form 5S8T Socket, Test Switch #TS07-0105
++
1LINE
C.T.LOAD2
P1 C+1
++
3
DIAGRAM F
P3 P2 C1 C+3 C3
C.T.
DIAGRAM F3∅3W “∆” with 2 C.T.’s2 Stator Meter - Form 5S
8T Socket, Test Switch #TS07-0105
+
+
C.T.LOAD
P1
+
+
P3 PN C+ C+
C.T.
C.T.
++
(BONDED)
DIAGRAM G
C C C+ C
1
LINE23N
DIAGRAM G3∅4W “Y” with 3 C.T.’s
2 1⁄2 Stator Meter - Form 6S13T Socket, Test Switch #TS10-0109
+
+
1
LINE
C.T.LOAD2
P1
+
+3
P3 PN C+
N
C.T.
C.T.
++
(BONDED)
+ +
PTPT
+ +
DIAGRAM H
C C+C+ CC
DIAGRAM H3∅4W “Y” with 2 P.T.’s & 3 C.T.’s
2 1⁄2 Stator Meter - Form 6S13T Socket, Test Switch #TS10-0109
+
+
1
LINE
C.T.LOAD2
P1
+
+3
P3 PN C+
N
C.T.
C.T.
++
(BONDED)
P2
DIAGRAM I
C C+ C C+ C
DIAGRAM I3∅4W “Y” or “∆” with 3 C.T.’s“Y” 3 Stator Meter - Form 9S“∆” 2 Stator Meter - Form 8S
13T Socket, Test Switch #TS10-0109
+
+
1
LINE
C.T.LOAD2
P1
+
+3
PN C+
N
C.T.
C.T.
+
+
(BONDED)
+ +PT PT
++
P3
PT
+ +
DIAGRAM J
P2 C C+ C C+ C
DIAGRAM J3∅4W “Y” with 3 P.T.’s & 3 C.T.’s
3 Stator Meter - Form 9S13T Socket, Test Switch #TS10-0109
DIAGRAM A
(ALT.LOC.)
++
+
+
ILINE
(BONDED)N C.T. LOAD
P1 PN C+1 C1
P.T.
DIAGRAM A1∅2W with 1 P.T. & 1 C.T.
Single Stator Meter(2W1∅) - Form 3S5T Socket, Test Switch #TS04-0101
(ALT.LOC.)
++I
LINE
(BONDED)N C.T.
LOAD2
DIAGRAM B
P1 PN C+1 C1
DIAGRAM B1∅3W with 1 C.T.
Single Stator Meter (2W1∅) - Form 3S5T Socket, Test Switch #TS04-0101
++
ILINE (BONDED)N
C.T.LOAD
2
P1 P2 C+1 C+
2 C2C+2
++
DIAGRAM C
C.T.
DIAGRAM C1∅3W with 2 C.T.’s
Single Stator Meter (3W1∅) - Form 4S6T Socket, Test Switch #TS07-0105
Pre-wiring: If standard factory pre-wiring is required, refer to wiring diagrams on this page. Determine appropriate diagram and send a copy with order. If custom factory pre-wiring is required, specify on order. Be sure to include meter socket catalog number, test switch make and catalog number, meter form number and provide a copy of your wiring diagram.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
60
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
This table is for concentric stranded conductors only. For cables with compact conductors refer to NEC. Refer to latest NEC Code or Local Codes for updated requirements.
TypeConductor Size
(AWG/kcmil)Conduit Trade Sizes (Inches)
1⁄2 3⁄4 1 11⁄4 11⁄2 2 21⁄2 3 31⁄2 4
THHN,THWN,
THWN-2
12 9 16 26 46 62 102 146 225 301 387
10 6 10 17 29 39 64 92 142 189 244
8 3 6 9 16 22 37 53 82 109 140
6 2 4 4 12 16 27 38 59 79 101
4 1 2 4 7 10 16 23 36 48 62
3 1 1 3 6 8 14 20 31 41 53
2 1 1 3 5 7 11 19 26 34 44
1 1 1 1 4 5 8 12 19 25 35
1/0 1 1 1 3 4 7 10 16 21 27
2/0 0 1 1 2 3 6 8 13 18 23
3/0 0 1 1 1 3 5 7 11 15 19
4/0 0 1 1 1 2 4 6 9 12 16
XHH,XHHW,
XHHW-2
4 1 2 4 7 10 16 24 37 49 63
2 1 1 3 5 7 12 17 26 35 45
1/0 1 1 1 3 4 7 10 16 22 28
2/0 0 1 1 2 3 6 9 13 18 23
4/0 0 1 1 1 2 4 6 9 12 16
250 0 0 1 1 1 3 5 7 10 13
350 0 0 1 1 1 2 3 6 7 10
500 0 0 0 1 1 1 2 4 5 7
750 0 0 0 0 1 1 1 3 4 5
MAXIMUM NUMBER OF CONDUCTORS IN CONDUITTable from 2008 NEC Code Reference: Rigid Metal Conduit
Conduit, Ampacity & SCCRReference Information
CONDUIT, AMPACITY &
SCCR
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
61
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
Energization of Electrical EquipmentImportant Information for Installers
ENERGIZATIONOF ELECTRICAL
EQUIPMENT
Before Energizing1. Give equipment a thorough visual examination to determine that: A. No shipping or installation damage exists. B. Proper clearances have been maintained. C. All connections have been made. D. Equipment is clean and dry.2. Make a thorough examination to: A. Verify tightness of all bolted connections (see table below). B. Manually operate all circuit breakers, switches, relays, etc. C. Check rigidity of all mountings, bus bars and components. D. Use test equipment to check continuity of circuitry and integrity of insulation.3. All switches and circuit breakers should be in the “off” position.4. Verify that manual meter bypass (if applicable) is in non-bypass position.5. Install cover and/or close doors.6. If installation is not being energized at this time, follow “after-energizing” steps listed below. These steps will secure the installation in case of accidental energization.
When EnergizingUse caution and follow established safety procedures: 1) Wear safety apparel. 2) Use safety equipment. 3) Take action to prevent injury to yourself and others in the event of failure of the installation. 4) Take action to prevent/decrease damage to property in the event of failure of the installation. 5) If you are unsure how to safely energize the installation, get someone who is knowledgeable to do it.
After EnergizingSecure the installation: 1) To prevent accidental contact with energized parts, cover all openings with approved filler devices. 2) To prevent unauthorized access, secure all covers and/or doors with approved security devices. 3) Attach/post information to advise others of potential hazards associated with the installation.
Important NoteIn addition to national and local electrical codes, many utilities have specific requirements for metering equipment. Always consult the serving utility for their specifications and requirements prior to ordering or installing Milbank meter mounting equipment.
* Interior labels typically indicate the required torque for wire connectors and studs, and should be referenced first.CU: CopperAL: Aluminum
Nominal Size
Joint DescriptionHead Type
Torque(Inch Lbs.)Screw Nut
10 Brass Brass Nut or Extruded Hole All 20-25 inch lbs.
10 Steel Copper or Aluminum Busbar ≤ 1/8" All 25-30 inch lbs.
10 Steel Steel Nut or Extruded Hole; CU or AL Busbar > 1/8" All 30-35 inch lbs.
12 Steel Aluminum Extruded Hole All 30-35 inch lbs.
12 Steel Steel Nut or Extruded Hole All 40-50 inch lbs.
1/4 Steel Aluminum Extruded Hole All 40-50 inch lbs.
1/4 Steel Steel Nut or Extruded Hole; CU or AL Busbar All 50-60 inch lbs.
5/16 Steel Aluminum Extruded Hole Hex 60-70 inch lbs.
5/16 Steel Steel Nut or Extruded Hole; CU or AL Busbar Hex 100-150 inch lbs.
3/8 Steel Steel Nut Hex 150-200 inch lbs.
1/2 Steel Steel Nut Hex 200-250 inch lbs.
Recommended Torque for General Applications*
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
62
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
Materials & FinishesReference Information
MATERIALS& FINISHES
Materials
Finish
Ratings & Compliance
The meter equipment listed in this catalog is made of galvanized steel (AISI* G90) to afford the best possible weather proofing. *American Iron and Steel Institute.
Steel Quality
16 gauge, galvanized, sheet: 1 1/4 oz./ sq.ft. class zinc-coated. (AISI G90)14 gauge, galvanized, sheet: 1 1/4 oz./ sq.ft. class zinc-coated.
Steel Sheet
Wire-Terminals: Alloy; 6061-T6, Tin-plated for CU/AL wire.Bus Bar: Alloy; 6101-O & 6063-O
Aluminum Extrusion
3000 series aluminum sheet, H14, or 5052 series aluminum sheet, H32. Where applicable thicknesses range from .064–.125
Aluminum Sheet
Electrolytic copper with tin plating in most applications.
Copper Sheet & Bus
• In most units, support bases for current-carrying components are molded from fiberglass reinforced high-strength, track resistant, thermoset polyester molding compounds.
• Clear or black safety shields and polarity barriers are molded from high-strength, track resistant, polycarbonate molding compounds.
• Various sheet insulating materials, as appropriate for the application are utilized in the fabrication of flat, formed and punched component parts and barriers.
Insulating Materials
Light gray state-of-the-art electrostatically applied powder paint offers a durable, non-fading finish. For further information concerning the chemical analysis of the weather resistant finish, please contact the factory.
Process
Zinc-coated with a chromate dip.
Metal Fastners
All Milbank electrical enclosures in this catalog are rated “Type 3R Enclosure” unless specified otherwise on the product’s page. All enclosures with a UL designation are constructed per the appropriate UL Standard and may be installed per the National Electric Code. UL procedure files associated with the UL Standards are listed as follows: Meter Sockets (UL 414, File E30202), Test Switches (UL 414, File E62531), Power Outlets (UL 231, File E90945), Panelboards (UL 67, File E32628) and Pullout Switches (UL 1429, File E133062). Additional standards are utilized as applicable: Meter Sockets (ANSI C12.7), Test Switches (ANSI C12.9) and Panelboards (NEMA PB-1).
Ratings & Compliance
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
63
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
Index
850........................................................466002......................................................466003......................................................466116......................................................46243210-CTC3R .....................................35304410-CTC3R .....................................35363612-LC3R-SP-WB ............................35484812-CT3R-WB .................................355T8K2 ...................................................47A7514 ...................................................45A7515 ...................................................45A7516 ...................................................45A7517 ...................................................45A7518 ...................................................45A7551 ...................................................45A7551 ...................................................45A8110 ...................................................45A8111 ...................................................45A8112 ...................................................45A9064 ...................................................45A-GP .....................................................46BL7474 .................................................47CP-21 ....................................................46K1047 ...................................................46K1190 ...................................................47K1350 ...................................................26K1350 ...................................................46K1350L .................................................46K1539 ...................................................26K1539 ...................................................46K1540 ...................................................26K1540 ...................................................46K1540L .................................................46K1541 ...................................................26K1541 ...................................................46K3082 ...................................................46K3083 ...................................................46K3356 ...................................................47K3441 ...................................................46K3442 ...................................................46K3865 ...................................................47K4527 ...................................................47K4528 ...................................................47K4977-EXT ............................................47K4977-INT ............................................47K5400-BRIDGE-2POS ...........................39K5935-10GR .........................................39K5935-11GR .........................................39
K5935-2/1450 .......................................39K5935-36GR .........................................39K5935-41 ..............................................39K5935-54 ..............................................39K5T .......................................................47K8180 ...................................................46M5-144 .................................................46Q115.....................................................44Q115H ..................................................44Q120.....................................................44Q120H ..................................................44Q125.....................................................44Q125H ..................................................44Q130.....................................................44Q130H ..................................................44Q135.....................................................44Q135H ..................................................44Q140.....................................................44Q140H ..................................................44Q150.....................................................44Q150H ..................................................44Q160.....................................................44Q160H ..................................................44Q170.....................................................44Q170H ..................................................44Q2100...................................................44Q2100H ................................................44Q2125...................................................44Q2125H ................................................44Q215.....................................................44Q215H ..................................................44Q220.....................................................44Q220H ..................................................44Q225.....................................................44Q225H ..................................................44Q230.....................................................44Q230H ..................................................44Q235.....................................................44Q235H ..................................................44Q240.....................................................44Q240H ..................................................44Q250.....................................................44Q250H ..................................................44Q260.....................................................44Q260H ..................................................44Q270.....................................................44Q270H ..................................................44Q280.....................................................44
Q280H ..................................................44Q290.....................................................44Q290H ..................................................44QN2150 ................................................44QN2150H .............................................44QN2150R ..............................................44QN2150RH ...........................................44QN2200 ................................................44QN2200H .............................................44QN2200R ..............................................44QN2200RH ...........................................44S4019-O ...............................................35S4020-O ...............................................35S4399-O ...............................................35S4400-O ...............................................35S8324....................................................45S8324....................................................45TS04-0101 ............................................33TS04-0102 ............................................33TS04-0103 ............................................33TS04-0104 ............................................33TS07-0018 ............................................33TS07-0022 ............................................33TS07-0049 ............................................33TS07-0059 ............................................33TS07-0105 ............................................33TS07-0106 ............................................33TS07-0107 ............................................33TS07-0108 ............................................33TS10-0109 ............................................33TS10-0110 ............................................33TS10-0111 ............................................33TS10-0112 ............................................33U1079-RRL-K3 ......................................11U1129-O-K3L-K2L ................................11U1232-RRL-KK-K1 .................................21U1233-RRL-KK-K1 .................................21U1234-RXL-KK-K1 ................................21U1252-RRL-KK-K1-BLG-SLVG ...............22U1252-RRL-KK-K1-SLVG .......................22U1253-RRL-KK-K1-BLG-SLVG ...............22U1253-RRL-KK-K1-SLVG .......................22U1254-RXL-KK-K1-BLG-SLVG ...............22U1254-RXL-KK-K1-SLVG .......................22U1255-RXL-KK-K1-BLG-SLVG ...............22U1255-RXL-KK-K1-SLVG .......................22U1256-RXL-KK-K1-BLG-SLVG ...............22U1256-RXL-KK-K1-SLVG .......................22
INDEX
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
64
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
Index
U1797-O-K3L-K2L ................................11U1797-O-K3L-K2L-BLG ........................11U1980-O-KK ...........................................9U1980-O-KK-BLG ...................................9U2120-X-K7 ..........................................12U2594-X ................................................12U2594-X-BLG ........................................12U2732-XT ..............................................25U2733-XT ..............................................25U2734-XT ..............................................25U2735-XT ..............................................25U2736-XT ..............................................25U2852-X ................................................26U2852-X ................................................27U2853-X ................................................26U2853-X ................................................27U2854-X ................................................26U2854-X ................................................27U2855-X ................................................26U2855-X ................................................27U2856-X ................................................26U2856-X ................................................27U2862-X ................................................26U2862-X ................................................27U2863-X ................................................26U2863-X ................................................27U2864-X ................................................26U2864-X ................................................27U2865-X ................................................26U2865-X ................................................27U2866-X ................................................26U2866-X ................................................27U2872-XT ..............................................24U2873-XT ..............................................24U2874-XT ..............................................24U2875-XT ..............................................24U2876-XT ..............................................24U3278-RL ..............................................10U3491-XL-200 .......................................14U3802 .....................................................6U3812 .....................................................6U3822-20GWR ........................................7U3832 .....................................................6U3862 .....................................................6U3989-XL ..............................................14U4363-X-QG-K3-K2 ..............................11U4408-O ...............................................35U4410-O ...............................................35
U4490-XL ..............................................32U4492-XL ..............................................32U4493-XL ..............................................32U4532-XL ................................................9U4835-X-2/200-BL ................................17U4881-O-50GB .......................................8U4881-O-60GB .......................................8U4905-X ................................................11U4905-X-BLG ........................................11U4908-O-11GR .....................................40U5000-XL ..............................................41U5000-XL-41 .........................................41U5000-XL-55 .........................................41U5000-XL-75 .........................................41U5059-X-2/200-K3L ..............................17U5059-X-K3L ........................................17U5100-XL ..............................................41U5100-XL-41 .........................................41U5100-XL-55 .........................................41U5100-XL-75 .........................................41U5101-XL-11GR ....................................40U5136-O ...............................................38U5136-O-100S ......................................38U5136-O-200S ......................................38U5137-O-200S ......................................38U5161-X-K3L-K2L-BLG .........................11U5168-XTL-100-KK ...............................15U5168-XTL-100-KK-BLG .......................15U5168-XTL-150-KK ...............................15U5168-XTL-150-KK-BLG .......................15U5168-XTL-200-KK ...............................15U5168-XTL-200-KK-BLG .......................15U5200-XL ..............................................42U5200-XL-41 .........................................42U5200-XL-55 .........................................42U5200-XL-75 .........................................42U5220-XL ..............................................42U5220-XL-41 .........................................42U5220-XL-55 .........................................42U5220-XL-75 .........................................42U5268-XTL-150-KK ...............................15U5268-XTL-200-KK ...............................15U5268-XTL-200-KK-BLG .......................15U5300-O ...............................................42U5300-O-41 ..........................................42U5300-O-55 ..........................................42U5300-O-75 ..........................................42U5320-O ...............................................42
U5320-O-41 ..........................................42U5320-O-55 ..........................................42U5320-O-75 ..........................................42U5750-RXL-200-BL ...............................16U5764-X-200-CB ..................................20U5765-X-200-CB ..................................20U5767-X-200-CB ..................................20U5784-O-200-CB ..................................20U5787-O-200-CB ..................................20U5796-X-400-CB ..................................20U5797-O-400-CB ..................................20U5799-O-400-CB ..................................20U5844-PXL-200-KK ...............................14U5844-PXL-200-KK-BLG .......................14U5871-XL-200 .......................................16U5882-X-KK-BLG ..................................28U5883-X-KK-BLG ..................................28U5884-X-KK-BLG ..................................28U5885-X-KK-BLG ..................................28U5886-X-KK-BLG ..................................28U5890-X-2/200-BL ................................17U5890-X-2/200-BLG .............................17U5891-X-2/200-MLK-BL .......................17U5898-O-100-KK-BLG ..........................15U5898-O-200-KK-BLG ..........................15U5902-X-KK-BLG ..................................28U5903-X-KK-BLG ..................................28U5904-X-KK-BLG ..................................28U5905-X-KK-BLG ..................................28U5906-X-KK-BLG ..................................28U5971-XL-100 .......................................13U5971-XL-150 .......................................13U5971-XL-200 .......................................13U5990-O ...............................................35U6115-X-2/200-K7L ..............................19U6227-X-400-K3L .................................18U6227-X-400-K3L-5T6 ..........................18U6227-X-400-K3L-5T9 ..........................18U6228-X-400-K3L .................................18U6228-X-400-K3L-5T6 ..........................18U6228-X-400-K3L-5T9 ..........................18U7021-RL-TG-KK ....................................9U7021-RL-TG-KK-BLG ............................9U7040-RL-TG-KK ....................................9U7040-RL-TG-KK-BLG ............................9U7040-XL-TG-KK ....................................9U7487-RL-TG-KK ....................................9U7487-RL-TG-KK-BLG ............................9
INDEX
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com
65
Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by
utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must
comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications
and features shown without notice or obligation.
Index
U9551-RRL ............................................10U9701-RRL ............................................10U9701-X-QG-BLG .................................10UAP6094-O ..........................................36UAP6095-O ..........................................36UAP6096-O ..........................................36UC1299-RL ...........................................30UC1300-RL ...........................................30UC7235-RL ...........................................30UC7237-XL ...........................................30UC7444-RL ...........................................31UC7445-RL ...........................................31UC7445-RL-641 ....................................31UC7445-WL ..........................................31UC7448-RL ...........................................31UC7449-RL ...........................................31UC7460-RL ...........................................31UC7461-RL ...........................................31UC7478-RL ...........................................31UC7532-RL ...........................................31UC7636-RL ...........................................31UQFB-100 .............................................43UQFB-100-X1 .......................................43UQFB-125 .............................................43UQFB-125-X1 .......................................43UQFB-150 .............................................43UQFB-150-X1 .......................................43UQFB-175 .............................................43UQFB-175-X1 .......................................43UQFB-200 .............................................43UQFB-200-X1 .......................................43UQFBH-100 ..........................................43UQFBH-125 ..........................................43UQFBH-150 ..........................................43UQFBH-175 ..........................................43UQFBH-200 ..........................................43UQFBH-M-100 ......................................43UQFBH-M-125 ......................................43UQFBH-M-150 ......................................43UQFBH-M-175 ......................................43UQFBH-M-200 ......................................43UQFP-100 .............................................43UQFP-125 .............................................43UQFP-150 .............................................43UQFP-175 .............................................43UQFP-200 .............................................43UQFPH-100 ..........................................43UQFPH-125 ..........................................43
UQFPH-150 ..........................................43UQFPH-175 ..........................................43UQFPH-200 ..........................................43UQFPH-M-100 ......................................43UQFPH-M-125 ......................................43UQFPH-M-150 ......................................43UQFPH-M-175 ......................................43UQFPH-M-200 ......................................43UQFP-M-100 ........................................43UQFP-M-125 ........................................43UQFP-M-150 ........................................43UQFP-M-175 ........................................43UQFP-M-200 ........................................43USE-22-200-MB ....................................13WBJ2150 ..............................................44WBJ2200 ..............................................44Z802964-AC .........................................47Z814898-AC .........................................47Z901925-AC .........................................47Z904486-AO .........................................47Z916264-AO .........................................47Z916265-AO .........................................47
INDEX
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com IN 3/18