Transcript
Page 1: HPLC, UHPLC, and UPLC Chemistry Consumables for …€¦ ·  · 2018-01-29HPLC UHPLC UPLC Oligonucleotide Separations Amino Acid Analysis Peptide Separations Protein Separations

Designed and QC tested with relevant biomolecules to help ensure consistency.www.waters.com/biosep

Vials Selectionwww.waters.com/vialsselector

Alliance

HPLC

HPLC Technology ■ Dispersion: >40 µL ■ Columns: ≥4.6 mm I.D., ≥3.5 µm particles

■ Recommended column: 4.6 mm I.D., 5 µm particles

■ Typical operating pressure: <5000 psi

ACQUITY Arc / Bio

UHPLC Technology ■ Dispersion: 20-30 µL ■ Columns: ≥3.0 mm I.D., 2–3 µm particles

■ Recommended column: 3.0 mm I.D., 2.5 µm particles

■ Typical operating pressure: <9500 psi

ACQUITY UPLC

H-Class / Bio

UPLC Technology ■ Dispersion <20 µL ■ Columns: ≥2.1 mm I.D., 1.6–2.7 µm particles

■ Recommended column: 2.1 mm I.D., 1.7 µm particles

■ Typical operating pressure: <18,000 psi

LC Categories

HPLC UHPLC UPLC

Oligonucleotide Separations

Amino Acid Analysis

Peptide Separations

Protein Separations

Reversed-Phase Columns For preparative column options, visit waters.com

■ ACQUITY™ UPLC™ Peptide CSH C18, 130Å X

■ ACQUITY UPLC Peptide BEH C18, 130Å X

■ ACQUITY UPLC Peptide BEH C18, 300Å X

■ ACQUITY UPLC Peptide HSS T3, 100Å X

■ XSelect™ Peptide CSH C18, 130Å X X

■ XBridge™ Peptide BEH C18, 130Å X X

■ XBridge Peptide BEH C18, 300Å X X

■ XSelect Peptide HSS T3, 100Å X X

■ Delta-Pak™ C18, 100Å X X

■ Delta-Pak C18, 300Å X X

Size-Exclusion Columns ■ ACQUITY UPLC Protein BEH SEC, 125Å X

■ XBridge Protein BEH SEC, 125Å X X

Ion-Exchange Columns ■ Protein-Pak™ Hi Res Q, SP, and CM X X X

■ BioSuite™ Q, DEAE, SP, and CM X X

Standards and Reagents

■ MassPREP™ Protein Digestion Standards X X X

■ Cytochrome c Digestion Standard X X X

■ Quantitative Peptide Retention Standard X X X

■ BEH125 SEC Protein Standard Mix X X X

■ IEX Cation Test Standard X X X

■ IEX Anion Test Standard X X X

■ RapiGest™ SF Surfactant X X X

Reversed-Phase Columns For preparative column options, visit waters.com

■ ACQUITY UPLC Protein BEH C4, 300Å X

■ BioResolve RP mAb Polyphenyl, 450Å X X X

■ MassPREP Micro Desalting X

■ XBridge Protein BEH C4, 300Å X X

■ Delta-Pak C4, 300Å X X

■ MassPREP On-Line Desalting X X

■ BioSuite pPhenyl X X

■ Symmetry300™ C4 X X

Size-Exclusion Columns

■ ACQUITY UPLC Protein BEH SEC, 125Å X

■ ACQUITY UPLC Protein BEH SEC, 200Å X

■ ACQUITY UPLC Protein BEH SEC, 450Å X

■ XBridge Protein BEH SEC, 125Å X X

■ XBridge Protein BEH SEC, 200Å X X

■ XBridge Protein BEH SEC, 450Å X X

■ BioSuite UHR, HR, and SEC X X

Ion-Exchange Columns ■ Protein-Pak Hi Res Q, SP, and CM X

■ Protein-Pak HR Q, DEAE, SP, and CM (glass) X X

■ BioSuite Q, DEAE, SP, and CM X X

Hydrophobic-Interaction Columns ■ Protein-Pak Hi Res HIC X X X

■ BioSuite Phenyl HIC X X

Standards and Reagents

■ MassPREP Protein Standard Mix X X X

■ BEH125 SEC Protein Standard Mix X X X

■ BEH200 SEC Protein Standard Mix X X X

■ BEH450 SEC Protein Standard Mix X X X

■ IEX Anion Test Standard X X X

■ IEX Cation Test Standard X X X

■ HIC Protein Standard Mix X X X

■ Intact mAb Mass Check Standard X X X

■ mAb Subunit Standard X X X

■ RapiGest SF Surfactant X X X

Reversed-Phase Columns ■ ACQUITY UPLC Oligonucleotide BEH C18, 130Å X

■ XBridge Oligonucleotide BEH C18, 130Å X X

Ion-Exchange Columns ■ Protein-Pak Hi Res Q X X X

■ Gen-Pak™ FAX X X

Standards and Reagents ■ MassPREP Oligonucleotide Standard X X X

Hydrophilic-Interaction Columns ■ ACQUITY UPLC Glycan BEH Amide, 130Å X

■ ACQUITY UPLC Glycoprotein BEH Amide, 300Å X

■ XBridge Glycan BEH Amide, 130Å X X

Standards, Reagents, and Kits

■ Glycoprotein Performance Test Standard X

■ GlycoWorks™ RapiFluor-MS™ N-Glycan Kit (96 sample, 24 sample, and automation kits) X X X

■ RapiFluor-MS and 2-AB Glycan Performance Test Standards X X X

■ RapiFluor-MS, 2-AB, and 2-AA Dextran Calibration Ladders X X X

Glycan and Glycoprotein Separations

Reversed-Phase Columns ■ AccQ•Tag™ Ultra C18 X

■ AccQ•Tag C18 X

Standards, Reagents, and Kits ■ AccQ•Tag Ultra Derivitization Kit X

■ Amino Acid Standards, Hydrolysate X X X

■ AccQ•Tag Derivitization Kit X

HPLC, UHPLC, AND UPLC CHEMISTRY CONSUMABLES FOR BIOSEPARATIONS

Waters maintains a Quality Management System in compliance with ISO 9001.

Waters owns and controls every step of the process; from raw materials to final product (few suppliers are capable of doing this). Understanding and controlling the processes makes the difference in product performance in your laboratory.

Manufacturer ofChromatographic Media

©2018 Waters Corporation. Waters and The Science of What’s Possible are registered trademarks of Waters Corporation. Alliance, ACQUITY, UPLC, BioResolve, GlycoWorks, RapiFluor-MS, XBridge, XSelect, Protein-Pak, BioSuite, MassPREP, RapiGest, Delta-Pak, Symmetry300, AccQ•Tag, Gen-Pak, and Arc are trademarks of Waters Corporation. All other trademarks are the property of their respective owners.

January 2018 720004232EN TC-SIG

HPLC UHPLC UPLC

HPLC UHPLC UPLC

HPLC UHPLC UPLC

HPLC UHPLC UPLC

HPLC UHPLC UPLC

Recommended