HMIs
Human Machine InterfacesHuman Machine Interfaces
HMIsHMIs
HMIs
Human Machine Interfaces
MP+MP+ TerminalsTerminals FutureFuture
TCP / IPTCP / IP
HMIs
E710E710
E700E700
E900E900E910E910
E300E300
E200E200
E100E100
E600E600
E900VTE900VT
The E-series of HMIs
E50E50
HMIs
E50 - low cost
Background lit text display 2x164 function keysRS422 with RS232 in the same Dsub +5 VDC, external or from PLCText blocks
HMIs
E100 - small but strongBackground lit text LCD-display2 rows x 20 characters4 function keysText blocksTime channelsReal-time clockRecipe handlingRS-232C and RS-422 ports+5 VDC, external or from PLC64 Kbytes flash memoryTransparent modeHMI Tools support
HMIs
E200 - As simple as it can beBackground lit text LCD-display4 rows x 20 characters, 5 mm text height5 function keys5 LEDs (two colour)Text blocksTime channelsReal-time clockRecipe handlingRS-232C and RS-422 ports64 Kbytes flash memoryTransparent modeHMI Tools support
HMIs
E300 - Low-end graphicBackground lit graphic LCD-displayTwo colours, 240 x 128 pixels8 function keys16 LEDs (two colour)Graphic and text blocksTime channelsReal time trendsRecipe handlingRS-232C and RS-422 ports1 expansion slot128 Kbytes Flash memory, expandable to 8MbTransparent modeHMI Tools and TCP/IP support
HMIs
E600 - one step upBackground lit graphic LCD-displayTwo colours, 240 x 128 pixels16 function keys16 LEDs (two colour)Graphic and text blocksFunctionality as E300Historical trendsRS-232C and RS-422 ports1 expansion slot256 Kbytes Flash memory, expandable to 8MbTransparent modeHMI Tools and TCP/IP support
HMIs
E700 - A trend composerBackground lit graphic LCD-display256 colours, 320 x 240 pixels16 function keys14 LEDs (two colour)Graphic and text blocksFunctionality as E600RS-232C and RS-422 ports2 expansion slots400 Kbytes Flash memory, expandable to 8MbTransparent mode HMI Tools support and TCP/IP support
HMIs
E710 - with new hardwareBackground lit graphic touch LCD-display256 colours, 320 x 240 pixels8 function keys8 LEDs (two color)Graphic and text blocksFunctionality as E700RS-232C and RS-422 ports2 expansion slots400 Kbytes Flash memory, expandable to 8MbTransparent modeHMI Tools support and TCP/IP support
HMIs
E900 - Even bigger
Background lit graphic colour display256 colours TFT, 640 x 480 pixels22 function keys20 LEDs (two colour)RS-232C and RS-422 ports2 expansion slots1.6 Mbytes Flash memory, expandable to 8Mb220 VAC power supplyTransparent modeHMI Tools and TCP/IP support
HMIs
E910 - touch it!Background lit graphic touch display256 colours TFT, 10,4”, 640 x 480 pixelsRS-232C and RS-422 ports2 expansion slots1.6 Mbytes Flash memory, expandable to 8MbDimensions 290 x 250 x 105 mm 220 VAC power supplyFunctionality as E900
24VDC version now available!
HMIs
E900VT - more inputs...Background lit graphic TFT-display256 colours, 10,4”, 640 x 480 pixel 22 + 28 function keys ( IFC-64E )20 two color + 28 green LEDsRS-232C and RS-422 ports1 expansion slot1.6 Mbytes Flash memory, expandable to 8Mb220 VAC power supplyFunctionality as the E900
HMIs
E610 - preliminary
Touchversion of E600B/W LCD displayCompactLow priceRelease Q4 2000
HMIs
Expansion cardsMemory expansion with IFC-MCIncrease project memory with up to 8Mb Back-up of recipes and projectsTransfer of files to other terminals
Profibus DP IFC-PBDPSlave connection to Profibus DP
TCP/IP network IFC-ETTP, IFC-ETCXTerminal network and Internetenable via Ethernet
HMIs
Expansion cardsExternal function keys with IFC-128EFor connection of up to 128 extra function-keys
Parallel printer with IFC-PIFor connection of an parallel printer
A-bus interface IFC-GA (E900/E910 only)Direct connection to the A-bus
HMIs
IFC-PI - Parallel printer port
Print outs of graphic and text blocks, reports and alarm lists– Graphics requires a HP PCL5, HP PCL6 or Epson FX80 compatible
printer
– If IFC PI is used a printer can not be connected to the RS-232 port
E300 and E600 have no support for HP PCL5/6 printers Black and white print outs only
HMIs
IFC-PI - Parallel printer portConnectable to
– E300 version 4.0 or higher (only with Epson FX-80) – E600 version 4.02 or higher (only with Epson FX-80)– E700 version 4.0 or higher– E710 version 4.0 or higher– E900 version 1.01 or higher– E910 version 4.02 or higher
HMIs
IFC-GA - Direct bus connectionWith the expansion card, IFC-GA, and the bus-interface A7GT-BUS installed, you can connect the E900 and E910 terminals directly to the base unit on an A(nS)-system.The communication between the PLC and the terminal will be very effective with the IFC-GA, because the terminal communicates directly with the A-bus on the PLC.
The standard RS-232/422 ports will be free for other equipment.
HMIs
Before: Today:
Omron.dll
Omron.hlpOmron.pdf
Terminal code+
Drivers
Project
Terminal code
Driver
Project
The new concept
HMIs
WEBWEB
The new conceptDownloadable driversDownloadable driversAll terminals in the E series from version 4.0The driver and the system program areseparated in the terminalNew drivers can be used without a update of MP+Installation via Internet using MP+ or from floppy (first download from web) Current driver is automatically transferred to the terminal by MP+New standard cables to new PLC systemsManual in pdf-format to each driver
HMIs
2 ports gives you freedomTransparent modeCommunication with the PLC system via the terminalMitsubishiOmronMatsushita
No protocol mode- Communication with external units i.e. barcode readers
Serial printer
HMIs
GPP/WINGPP/WIN MM+ MM+
Transparent mode
Reach PLC through terminal in operationOnline changesEasier troubleshooting
HMIs
Individual customised products - from simple panels to PC platforms Integration into your machine designCustomised OEM products, your operator control concept in style and functionality
What can we offer you:
• Individual design and front layout
• Modular Hardware
• Flexible Software
• We will implement your requirements
- So You can be successfully in business
• Professionalism and competence is our name
And You:
Be an individual...
Are you an individual?
HMIs
The lifecycle - Of a terminal...Even at the design stage we try to think in a long time perspective The choose of :
– Components– Material Recycled Recycling– Handling– Transports Minimum
And in the end...We take care of old used products, and sees that every part is handled in a minimum non-polluting way.As our contribution to the environment .
HMIs
The usual information way
RUN STOP
FWD REV
OperatorProcess/MachineProcess/Machine
Do it the hard way...
HMIs
HMIHMI
Or the easy way!HMI as information provider!
The HMI-solution gives you:Information in a easy wayThe Information will be clear and in right timeEasier to determine when changes occur
Process/MachineProcess/MachineOperator
HMIs
You will save:Money
Effective
Flexible
Simplicity
Time
Easy - Handle
Quick - Learn
Simple - Install
Right information - In Right Time
HMIs
6
Basic functionsAlarm handlingRecipe handlingRealtime clockTime channelsTrend diagramPassword handling
HMIs
E 710
Operator interfaceTextGraphicColorsTouch screenLEDsFunctionkeysPrintouts
HMIs
Mac Programmer+Easy to useWindows 95, 98, 2000 and NTDocumentationBack-upFull support for Windowscopy/pasteToolbox and ToolTipsMultiple project can be open at the same timeCompatible name list with MELSEC MEDOC and MELSEC MEDOC +Support for MXChange
HMIs
Structure
Using a tree structure when developing a project
HMIs
Block manager
Simplifying the handling of the blocks.Gives the engineer a visual overview how the project is created.
HMIs
Object basedAll object data is stored in the terminalThe signals is configured directly in the objectNo PLC-programming is needed*Only the object´s which is viewed on the screen is updated
* except Profibus
HMIs
Downloadable drivers
Now you are just a click from upgrading your drivers
HMIs
The Internal Name list
For easy changing of different PLC devices
HMIs
Message library
Manoeuvrable message objects– 64 libraries can be manoeuvrable with 512 texts,
40 characters– Values between 0-65535 can be linked with texts
HMIs
News in Mac Programmer+
32-bit version to Windows 95, 98, 2000 and NT Supporting downloadable driversSupporting TCP/IP networkInstallation from CD
HMIs
News in Mac Programmer+
New configuration of peripheral unitsAcknowledge of individual alarms from the PLC systemAlarm on the negative edge
HMIs
More news!Modem handling in all terminals except E50
– Call up with the terminal– 10 different numbers stored in the terminal– 1 number stored in the PLC system
Larger size on the alarm text in E900System monitor in E700, E710, E900 and E910
HMIs
More news!
Show terminal in text blocksPrinting text strips to all terminals from MP+Improved project documentation in print-outsUse terminal font in MP+Cursor colour in the alarm list can be changed
HMIs
And more….Recipes sorted in alphabetic orderTurning off printing from the PLC system to avoid conflicts when transparent mode is usedMin- and max limits on numeric objects in graphic blocksThe alarm group name can contain national charactersNew data formats
– HEX 16-bit, 32-bit– BCD 16-bit, 32-bit– Float without exponent
HMIs
The Installation CDMAC Programmer+ 32-bitHMI Tools 32-bit All current driversManuals to all products
– E-series and MAC-series– Expansion cards– Installation manuals– Drivers
Floppy-copying of Full version, Demo and Transfer
HMIs
New manualsNew E-series manual
– The same manual to all E-terminals and MP+
New installation manual– The same manual to all E-terminals– Enclosed with all terminals
Separate manual to each driver– Downloaded with the driver in MP+
All pdf-manuals are available at WEB-site and on installation CD
HMIs
HMI ToolsWindows 95, 98, 2000 and NT Transferring of recipes, trends and alarm listsDownloading of system programsCommunication via modem
MP+ Transfer is a separate program
HMIsWhy choose an operator terminal from Mitsubishi?High QualityUser friendlyFunctionalityOne Software for all terminalsPossibility to upgrade the operating systemHigh quality supportAnd of course the openness
HMIs
http://www.mitsubishi.co.uk/automationhttp://www.mitsubishi.co.uk/automationhttp://www.e-terminals.comhttp://www.e-terminals.com
Support at the webDownloadable:Latest versions of software's Demo ProjectsProduct newsDriversManualsManufacturer´s declarationsUpcoming featuresApplication examplesFAQ
HMIs
The Open Concept
The Open Concept
Drivers & Connections
HMIs
DriversMelsec A (C24*, CPU, E71** or Profibus DP**)Melsec A-bus (A-bus*)Melsec A CC-Link connection (AJ65BT-G4)Melsec FX (CPU or 485ADP*)Melsec QnA (QC24*, QCPU* or Profibus DP**)Freqrol FR-A/EMelservo MRJ2CS100
* Can not be used with E50** Can not be used with E50, E100 or E200
HMIs
Drivers
SIMATIC S5 (3964R/RK512*, PG-port* or Profibus DP**)SIMATIC S7 (3964R/RK512*, MPI*, PPI or Profibus DP**)
* Can not be used with E50** Can not be used with E50, E100 or E200
HMIs
DriversABB
– SattCon (Comli master*)
Allen-Bradley– Micrologix (DF1)– SLC500 (DF1 or DH485**)
Control Techniques– Unidrive (ANSI*)
Delta Tau– PMAC, UMAC (ASCII*)
Demonstration driver– Internal in the HMI
DVT Vision System– SmartImage Sensor (ASCII or TCP/IP**)
Festo/Beck– IPC, FEC series (FXT CI*)
GE Fanuc– Series 90 (SNPX)
Hitachi– H Series (HCOM*)
IAI– SuperSEL (Serial*)
* Can not be used with E50** Can not be used with E50, E100 or E200
HMIs
DriversIdec
– FA-1/2/Junior/Micro1 (FA-series 1:1 expanded*)
– FA-3 (FA series 1:1*)
– MICRO3/3C (Micro Computer Link)
Klockner Moeller– PS4 series (SUCOM-A*)
Koyo– Direct logic series (DirectNET* or K-sequence)
Matsushita– FP-series (MEWTOCOL-COM)
Modicon– All PLC types (Modbus master ASCII/RTU or
Modbus slave RTU*)MXCC
– VLC (Serial* or Profibus DP**)
Omron– All PLC types (Hostlink)
* Can not be used with E50** Can not be used with E50, E100 or E200
HMIs
DrivesSAIA
– PCD series (SBUS*)
SEW Eurodrive– Movidrive (Movilink*)– Movidyn (Movidyn*)– Movitrac (Movitrac*)
Telemecanique– TSK series (UniTelway*)
Toshiba– PROSEC T-series (Computer Link)
VT100Yaskawa
– MP9xx series (MemoBus master RTU*)
* Can not be used with E50** Can not be used with E50, E100 or E200
… … and more will come!and more will come!
HMIs
How to make a connection
HMIs
TCP/IPor
UDP/IP
BDTP
PLC-programE71-profile
IFC-ETCX
Server
Client
Client
Mitsubishi - E71 driver
The PLC-systems in Melsec A/QnA(S)-series via AJ71E71 or AJ71QE71 using the ASCII protocol.All E-series terminals can be used, with the exception of E100 and E200.Requires Ethernet card.
HMIs
Mitsubishi - MELSERVOAll E-series terminals can be usedMR-J2-C-S100RS422 or RS232 connectionMultidrop of up to 32 servos possibleRead/Write all inverter parameters, digital/analog signals, alarm codesAll E-series functionality available (text/graphic, trending, recipe, reporting, networking …)
HMIs
Point-to-point
MultidropRS-485
RS-422
RS-232
Default station number
Mitsubishi - MELSERVO
Cable as drawing in the manual
HMIs
FREQROL FR-A/FR-EAll E-series terminals can be usedFR-A and FR-E seriesRS422 or RS232 connectionMultidrop of up to 32 inverters possibleRead/Write all inverter parameters, digital/analog signals, alarm codesAll E-series functionality available (text/graphic, trending, recipe, reporting, networking …)
HMIs
FREQROL FR-A/FR-E
Cable as drawing in the manual
Point-to-point
MultidropDefault station number
RS-422
PU-Port
FR-A5NR
CAB-9
PU-Port
SC-FRPC
RS-422
RS-232 RJ45
HMIs
MXCC <-> E-series alt.1
PROFIBUS-DP connectionE300-900 can be connectedMXCC-program handles the HMI-profile
HMIs
RS232
I/O-bus
MXCC <-> E-series alt. 2 Serial connectionMXCC-program (Profile) All E-series HMIs can be usedLow price connectionSurvives NT-crashTerminal network through Ethernet possible
HMIs
Cable as drawing in the manual
ABB - COMLI Master
Supports multidrop
RS-422RS-485
Nod ID:
CAB-8
CA
B8
HMIs
Allen-Bradley DF1 Micrologix
The PLC-systems in the Micrologix 1000-series
CAB-2
RS-232
This node = TerminalRemote node = PLC
CRC-16 checksumFull duplex
8-polMini-Din
HMIs
Allen-Bradley DF1 SLC-500
The PLC-systems SLC 500, SLC 5/01, SLC 5/02, SLC 5/03 and SLC 5/04Requires the module 1747-KE, 700 DEM(The DF1 connection at SLC 5/03 and SLC 5/04 is not recommended because of more disturbance)
CAB-5
RS-232
This node = TerminalRemote node = PLC
CRC-16 checksumFull duplex
Cable 1747-C13from Allen-Bradley
DH-485
HMIs
Control Technique - UNIDRIVE
All E-series terminals can be usedInverters in the Unidrive series with serial interface i. e. UD 71.RS422 or RS232 connectionMultidrop of up to 32 servos possibleRead/Write all controllers parameters, digital/analog signals, alarm codesAll E-series functionality available (text/graphic, trending, recipe, reporting, networking …)
HMIs
Point-to-point
Multidrop
Default station number
RS-422
RS-422
RS-485CAB-8C
AB
8
RS-422
2-wire
4-wire
RS-422
Control Technique - UNIDRIVE
Cable as drawing in the manual
HMIs
Delta Tau - PMAC/UMAC
All E-series terminals can be usedRS422 or RS232 connectionPoint to Point or Multidrop Read/Write all controllers parameters, digital/analog signals, alarm codesAll E-series functionality available (text/graphic, trending, recipe, reporting, networking …)
HMIs
MAC 40+-CAB
RS-422
Default station number
Multidrop is performed by a band cable between the PMAC/UMAC systems
Delta Tau - PMAC/UMAC
The Positioning-system in Delta Tau PMAC/UMAC-series
HMIs
Demonstration driver
Driver for demonstration without PLC-system99 M-coils99 data registers4 counters4 timers
HMIs
GE Fanuc SNPX
The terminals supports all GE Fanuc PLC systems, connected via the SNPX protocol.
RS-422
CAB-4
SNP ID numberNo PLC-programrequires for thecommunication
HMIs
RS-422
Idec8-pol
connector
RJ11
RS-422
Contain electronically devices, se driver manual
Idec - FA series
The PLC-systems in Idec FA-series
Cable as drawing in the manual
HMIs
RS-422
RS-232
8-polMini-din
8-polMini-din
Default station number
RS-485CAB-8
CA
B8I
Alt.I
Idec - Micro 3-series
The PLC-systems in Idec Micro 3-series
Cable as drawing in the manual
HMIs
RS-422
RS-232
RS-232
15-pol
15-pol
RJ12
Default station number
Koyo - DirecNet & K-Sequence
Koyo Direct Logic Series K-Sequence PLC Koyo via the DirectNET
Cable as drawing in the manual
HMIs
RS-422
RS-232
RS-232
15-pol
9-pol
5-polMini-Din
Default station number
Matsushita - FP seriesThe PLC-systems in Matsushita FP-series via the MEWTOCOL-COM protocol
Cable as drawing in the manual
HMIs
Modbus ASCII / RTU
Supports Multidrop
RS-422RS-485
CAB-8
CA
B8
Default station number
Cable as drawing in the manual
HMIs
Omron Hostlink
The terminals supports all Omron PLC systems, connected via the Hostlink protocol.Supports transparent mode
CAB-3
RS-232
No PLC-programrequires for thecommunication
Default station number
HMIs
Siemens SIMATIC S5 PG1/AS511
The PLC-systems SIMATIC S5 90, 115, 135 and 155
No PLC-programrequires for thecommunication
CAB-7
CAB-1
Siemens Converter 6ES5 734-1BD20
RS-232
RS-422
HMIs
Siemens SIMATIC S5 3964R/RK512
The PLC-systems SIMATIC S5 90, 115, 135 and 155Requires communication card CP525Writing is only possible to DB, other devices can only be read
CAB-6
CAB-5 RS-232
RS-422
Null modem
The terminalHigher priority=Master
PLC3964R / RK512=Slave
HMIs
Siemens SIMATIC S5 Profibus DP
The PLC-systems SIMATIC S5 90, 115, 135 and 155Requires Profibus DP interface (IFC-PBDP)
IFC-PBDP
PLC programHMI-profile
Requires timedelay in connection with
fast CPU:s
HMIs
Siemens SIMATIC S7 MPI
The PLC-systems SIMATIC S7 300- and 400-series
CAB-6
CAB-5
RS-232
The MPI station number of the terminal
The MPI stationnumber of the PLC system
Highest MPI address
RS-422
+CAB-11
HMIs
Siemens SIMATIC S7 PPI
The PLC-systems SIMATIC S7 200-series
Cable as drawing in the manual
CAB-8
RS-422
The station number of the terminalThe stationnumber of the PLC-system
Highest PPI address
Only the terminal can be Master in
the network PPI-Port
HMIs
Siemens SIMATIC S7 3964R/RK512
The PLC-systems SIMATIC S7 300- and 400-seriesRequires communication card CP341Writing is only possible to DB, other devices can only be read
CAB-5
RS-232
The terminalHigher priority
MasterPLC
3964R/RK512Slave
HMIs
Siemens SIMATIC S7 Profibus DP
The PLC-systems SIMATIC S7 300- and 400-series Requires Profibus DP interface (IFC-PBDP)
IFC-PBDP
PLC-programHMI-profile
HMIs
Toshiba
The PLC-systems in PROSEC T-series via Multidrop connection
Cable as drawing in the manual
MAC30/40-CAB
RS-422
RS-422
CR-01
The Computer Link protocol
RS-485 RS-232RS-485RS-485
CR
-01
Default station number
HMIs
CablesCAB1
– cable to connect Siemens SIMATIC S5/PG1 via Siemens Converter to the RS-232-port on the terminals in the E-series. 0,5 m.
CAB2 – cable to connect Allen-Bradley's PLC system Micrologix to the RS-232-port on the terminals in the E-
series. 3 m.
CAB3 – cable to connect Omron PLC system via the Hostlink protocol to the RS-232-port on the terminals in the E-
series. 3 m.
HMIs
CablesCAB4
– cable to connect GE Fanuc PLC system via the SNPX protocol to the RS-422-port on the terminals in the E-series. 3 m.
CAB5 – cable to connect Siemens SIMATIC S7/MPI via Siemens HMI Adapter, Siemens
SIMATIC S7/3964R, Siemens SIMATIC S5/3964R and Allen-Bradley/DF1 PLC-systems to the RS-232-port on the terminals in the E-series and to connect a PC to the RS-232-port on the terminals in the E-series. (MAC PROG/9-CAB) 3 m.
HMIs
CablesCAB6
– cable to connect Siemens SIMATIC S7/MPI via Siemens HMI Adapter, Siemens SIMATIC S5/3964R and PC to the RS-422-port on the terminals in the E-series. 3 m.
CAB7 – cable to connect Siemens SIMATIC S5/PG1 straight to the RS-422-port on the
terminals in the E-series. 3 m.
HMIs
Cables
CAB8– to connect the terminals in the E-series to PLC-systems via RS-485.
Adapter placed on the RS-422-port at the terminals.
CAB9 – cable to connect Mitsubishi Fr-A / E inverters straight to the RS-422-
port on the terminals in the E-series. 3 m.
HMIs2 serial ports gives you freedomTransparent mode
– Communication with the PLCsystem via the terminal, online
No protocol mode– Communication with external units
Serial Printer– Communication with a serial printer
HMIs
Messagepacket
The Communication”Point to point”, master/slave
– Terminal read/write information.– PLC replys on requested information.
Signals which effects the communication time– Overhead signals except signals in the current block.– alarms, trends, display-signals,
LED-registers, block-prints, index, register for PLC-watch etc.
HMIs
The CommunicationSignals which NOT effects the communication time
– Signals connected to function
– keys, time channels, objects in alarm texts.
Effective communication = (as few message packets as possible)– Group signals.
– Don’t dump the watch with to short interval.
– Block change with display register.
– Packaging of signals (consecutive order).
Messagepacket
HMIsThe future requires new conceptsNew concepts reach new markets -new markets gives us new customersOpenness is one key to the futureMore effective development work Even higher quality
HMIs
Internet technology
More openness
PC-based HMI functionality
Windows CE
More efficient tools
Internet technology
More openness
PC-based HMI functionality
Windows CE
More efficient tools
High functionalityEasy handlingOptimized for Mitsubishi Electric products
High functionalityEasy handlingOptimized for Mitsubishi Electric products
The HMI strategy
HMIs
* Supervisory connectivity- Remote HMI/PLC process monitoring/control- Diagnostics- Statistic reporting- Internet connection- Data file exchange
* Plant floor connectivity- All major PLC:s- PC-based control systems- Fieldbuses- Local networks
* Flexible HMI application- Data exchange with Word, VB, Excel.- Reuse of objects- More options for advanced users
* OPEN STANDARDS !- TCP/IP-Ethernet.- Windows CE/NT/95- OPC, ActiveX, COM/DCOM- Internet technology
Future customer requirements
HMIs
Product hierarchy
CEZARCEZAR
SCADA system
Operator terminals
- Graphic
- Text
HMIs
CEZAR concept
MicrosoftMicrosoft®®
Windows NTWindows NT®®
MicrosoftMicrosoft®®
Windows CEWindows CE®®
C-terminalsAdaptions for NT / NT-E / CE
environment
Same concept-different platforms
DesktopAdaptions for NT
environment
HMIs
CEZAR concept
The CEZAR-RT and the CEZAR software will check if all the necessary components exist on the target platform. If not, they will be distributed automatically by the software.
CEZARDeveloping tool
*The Terminal Client Application must be purchased separate
CEZAR-RT( TCA )( TCA )
C-Terminal Any PC
The Terminal Client Application isalways included in the C-terminals
CEZAR-RT( TCA* )
HMIs
6
Basic functionsAlarm handlingRecipe handlingReal-time clockTime channelsTrend diagramsPassword handling
HMIs
E 710
125º
Operator interfaceTextGraphic/PicturesColoursTouch screenPrint-outsPossibility to start otherWindows applications
HMIs
3. Enterprise3. Enterprise2. Professional2. Professional1. Basic1. Basic
CEZAR developing toolThree selectable user levels:
Event driven programming (level 2-3)Programming withVisual Basic-script (level 3)Drag n’ DropActiveX controls Copy/Paste fromWindows
HMIs
Improved HMI functionality (1)Data exchange with... Script language using… Extended character support- Unicode- True Type FontsMultimedia support- Video- Sound
HMIs
Improved HMI functionality (2)Internet access
– Web Server - Allow access from other sites– Web Client - Get data from other sites
Network possibilities– Distributed objects– Shared data files (alarm list, application)– Network with NT-stations
HMIs
Open systemMicrosoft technology:
– OPC - allows for 3.rd party drivers– COM/ActiveX - object component base– DCOM - distributed objects
Objects based:– Object accessible from external applications– Reuse of objects– Customer can create new objects
HMIs
CEZAR Connections
USB-PortsUSB-Ports2 x USB
Ethernet-PortEthernet-PortTP with RJ45
Parallell-PortParallell-Port
Serial-PortsSerial-Ports1 x RS4222 x RS232
Support for Multiple drivers
How many inputs do You have?
HMIs
MicrosoftMicrosoft®®
Windows NTWindows NT®®
Hardware specification NT (1)Intel/Pentium MMX 266 processor12.1” Touch TFT display, 800*600, 256 K coloursC&T 69000, 2MB SDRAM video Chips64 MB RAM memory, expandable to 128 MB6.1 GB hard drive , 2.5", EIDE2 x USB ports2 x RS-232 portsRS-422
HMIs
Hardware specification NT (2)
Parallel portEthernet TP 100M, RJ-45 connector
32 bit PCI slot, 2 brackets2 x 16 bit PC104 slot, stackedKeyboard, Mouse and sound* connectors
MicrosoftMicrosoft®®
Windows NTWindows NT®®
* Optional
HMIs
Future developments
HMIs
Development areasMore E-series drivers will still comeStrengthen low-end area of E-seriesEX classified environmentIntegration of Internet-technologyUse the benefits from Windows CE and NTAnd...
HMIs
The HMI WEB
HMIs
BDTP
Server Client Server/Client
Overview TCP/IP networkFunctionality
– Terminal network, replacing MAC network, 10Mbit/s– Transfer data between PLC-systems– Project transfer– More will come ...
Connection possibilities– Ethernet Twisted Pair or coaxial– Serial
New expansion cards– IFC ETTP, Twisted Pair – IFC ETCX, Coaxial
HMIsOverview TCP/IP network - twisted pairIFC ETTP in each terminalMaximum length between terminal and HUB is 100 mTwisted pair CAT5, shielded or not shieldedRJ45 connectorThe number of connections on the HUB settles the maximum number of terminals connected to each HUBNo HUB if only two terminals
HMIs
SegmentSegment
Overview TCP/IP network - coaxial cableIFC ETCX in each terminalMaximum length on each segment is 185 mMaximum 30 units on each segmentMaximum 5 segments can be connected via repeaters and maximum 3 segments can have unitsCoaxial cable RG58Termination 50
HMIs
BDTP improvements in version 5Server Alarms
– - Define the alarm in the server,this will be sent to all the clients automatically when the signal is activated.
RAS* functionality– Automatic restart of clients when server restart.
* Recovery Automatically System
HMIsAvailable now!Available now!TCP/IP - step 2
Intranet / Internet connectionRemote monitoring/Maneuvering
– Via web-sites– Free Browser
Data transfer– FTP transfer
E-mail– SMTP
HMIs
Local connections
Intranet– Local factory network– Good response time– Local domains
Call-up Intranet– World-wide access– Good response time– Local domains
HMIs
W.W.W.
Global connection - www
Internet– Published on the WEB.– Uncertain response time.– Global domains.– Mainly for data of public interest.
HMIs
HTMLblablablabbl
HTMLblablablabbl
HTMLHTML
HTML<ssi>-------l-----
Standard Web Browser(Internet Explorer,Netscape Navigator)
W.W.W.
WEB Server
WEB server Each terminal has a homepage. HTML-pages can contain real-time and PLC/HMI-data HTML-pages are created on PC and downloaded to the terminal
HMIs
W.W.W.
WEB server - remoteMonitoring/Manoeuvring and Control
HMIs
W.W.W.
WEB server - remoteMonitoring/Manoeuvring and Control
HMIs
HTML codesUser HTML-pages withSSI-code
– <-!get_date.fn-!->– <-!get_time.fn-!->– <-!get_diag.fn-!->– <-!get_ipaddr.fn-!->– <-!get_domainname.fn-!->– <-!get_mode.fn-!->– <-!get_device.fn-!->
Function executed when server sees special codes
Standard Web Browser(Internet Explorer,Netscape Navigator)
W.W.W.
HMIs
HTML codes
User HTML-pages withCGI-Scripts
– <-!set_date.fn-!->
– <-!get_time.fn-!->
– <-!set_mode.fn-!->
– <-!set_device.fn-!->
Standard Web Browser(Internet Explorer,Netscape Navigator)
W.W.W.
HMIs
HTML codes
HMIs
Standard Web Browser(Internet Explorer,Netscape Navigator)
W.W.W.
WEB server - remoteMonitoring/Manoeuvring and Control
JAVA AppletView current screen of terminalRemote control terminal by mouse clicks on PC
HMIs
W.W.W.
WEB server - remoteMonitoring/Manoeuvring and Control
HMIs
Standard FTP client(Included in Internet Explorer,Netscape Navigator)
W.W.W.
FTP Server
FTP server - data transferProcess data transfer
– Recipes
– log / Trend data
– Alarm list
Application data transfer– HTML files
HMIs
GPP/WIN (2001)MM+ (April 2001)
W.W.W.
Transparent modeReach PLC through networkRequires support from PLC configuration softwareTunneling PLC-protocols
HMIs
Standard POP3 Mail server
SMTP Client
Outlook Express/Netscape.(POP3)Can redirect mails to f.ex GSM texts
W.W.W.
You have mail...
Mail on alarmReports through e-mail (textblock)Forwarding E-mails
HMIs
GOT Product line up
F900GOT
A900GOT
GOT Software
HMIs
F900GOT Range
F940GOT– F940GOT-LWD-E
Monochrome– F940GOT-SWD-E– 8 colours
F930GOT-BWD-E– Monochrome
HMIs
F900GOT functionsTouch screen with IP66F(F940GOT)Security function1:n Network Transparent ModeAlarm functionRecipe functionDevice MonitorGraphical and Text-Objects F940GOT replaces and contains all functions of FX-50DU-TK(S)-E
HMIs
Communication connections
FX1, FX2, FX2C, FX0, FX0S, FX0N, FX2N,FX2NC
Q/A series
OMRON SYSMAC C seriesFUJI N series
PC board
PLC
CPU direct connection
CPU direct, PC link
CPU direct, RS232C
RS232C
Connection method
PC link
Allen-Bradley PLC SLC500 series
* Connection to Siemens PLC is also planned.
HMIs
146 mm 49 mm
75 m
mF930GOT-BWD-E Dimensions
Display size : 4.4-inch (280 x 80 dots)Display colour: 2-colour (blue/white)Display device: STNTouch switches: 4 x 15 = 60
(50 positions/screen can be set.)
HMIs
F930GOT benefitsSmall and Compact high performance GOT Dimensional analysis:
– Outer dimensions: 146 x 75mm– Depth: 49mm (45mm recessed into panel)
High resolution / Industry’s Premiere Resolution – The 240 x 80-dot screen (15 x 5 lines) provides the industry’s highest resolution in the small-class display category.
Long-Life Backlight / Industry’s Longest Lasting Backlight.– A full 50,000 hours of operation with a single Backlight.– This long-life Backlight offers maintenance-free operation.
HMIs
F930GOT benefitsQuick One-Touch Switching
– The FX2N and FX2NC series connected (direct CPU connection)– One-touch operations are conducted in 0.16sec with high-speed response.
Simple Multiple Connectivity (up to 4 GOTs maximum)– Using direct CPU connections with the MELSEC FX or A Series– A maximum of 4 F930GOTs can be connected to a sequencer.
HMIs
F930GOT-BWD-E IP66F Rating146 x 75 x 49mm- classed as the worlds smallest control unit.Easier on the eyes than any comparable screen on the market. Easy-to-read wide-angle LCD.Network expansion a standard feature for up to four units.Sampling mode for measurements and recording.
HMIs
Networking Hardware
Terminal Network with up to 4 stations possibleTransparent mode
Main control panel
remote‚P remote‚Q remote‚R remote‚S
30m 15m 30m 15m
RS422RS232C RS422 RS232C
PLC
HMIs
45°
60°
50° 50°
F940GOT Display properties
Display properties– 320 x 240 Pixel– STN LCD – 8 colours or Monochrome– Excellent view from all angles
HMIs
•5.7in Terminal with less Dimension
•Water and oil resistent
•IP66F!
Display5.7In
162
11523.5 23.5Frame
130
8522
.522
.5(F
ram
e)
57F940GOT Dimensions
Compact size
HMIs
Comparison of terminals
CategoryCategory
Touch keys
Parameters
Lamps
Memory
Freq.
Varieties
Display mode
Trigger
Alarmmode
FX-50DU-TKSFX-50DU-TKS F940GOTF940GOT
Samplingmode
History
32
Number
50
I/O
30 50
2,000
Dust/Water/Oil
2,000
IP65 IP65F
50 50
128K 512K
50 256
Same
+Oil resist.
800 2,000
200 1,000
2 4
x 2.5
ComparisonComparison
x 1.6
x 1.7
Same
x 4
x 5.1
x 5
x 2
HMIs
Mitsubishi’s new GOT’sA900GOT seriesA985GOT-TBA-EU
– 256 colours 800x600 Pixel TFT 12”
A975GOT-TBA-B-EU– 256 colours 640x480 Pixel TFT 10,4“
A970GOT-SBA-B-EU– 16 colours 640x480 Pixel STN 10,4“
A960GOT-EBA-EU– Monochrome 640x400 Pixel EL 8,9“
HMIs
Introducing A900GOT High speed screen data transfers and OS transfers.
– also store screen data from a GOT in a memory card (PCMCIA) and then edit to a PC
List program edit function– minor modification can be made on site– compatible with MELSEC-A Series– command list offers to write, monitor, insert, delete and parameter edit functions
HMIs
Improved recipe handler
Programmable controller
D101D102D103
D***
Data 1Data 2Data 3
Data mm=Max. m=Max.
8k words8k words
n =Max. n =Max. 256256
Recipe data n
Recipe data 2
Recipe data 1
Commercial SRAM card or flash PC card
HMIs
Recipes
Mem.card
Bus connection and RecipesFast Bus Connections
– use a MELSEC-A/QnA programmable controller for the fastest bus connection. – You can achieve similar performance from three GOTs connected by bus as from a
single connected GOT– high speed response via a bus connection for cyclic communication
Recipe functions– data can be stored onto memory cards useable by other GOTs
HMIs
Password input
A900GOT Security
Security functions– 16 security levels
HMIsA900GOT Communication speed
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
FX CC-LINKtransient
CC-LINKcyclic
MNETtransient
MNETcyclic
UC24 Bus
Bus connection is fastest
HMIs
A900GOT dimensions
46mm
Size (W x H x D):
297 x 208 x 46 for colour Terminals268 x 192 x 49 for EL Terminal
Extremely slim and compactSlim line terminal using new Bus or RS422 communication modules
HMIs
ConnectionsA9GT-BUSS
– Bus connection
A9GT-RS4– Serial connection
PCMCIA card (withQnA series)– Memory cards for programs and recipe
HMIs
PLC connection
FX1, FX2, FX2C, FX0, FX0S, FX0N, FX2N, FX2NC
Q/A series
OMRON SYSMAC C seriesYasukawa series
PLC
CPU direct communication
CPU direct, PC link, A-Bus and Networks.
RS232C
Connection method
PC link
Allen-Bradley PLC SLC500 series
HMIs
GOT Software
GT Works, one Software for all GOT (AGOT and FGOT) (SWnD5C-GOTRE-E)FX-DU-SW-WIN-E (Ver.2.30) only for FGOT
F900GOT
FX-DU-WIN-SW-E SW4D5C-GOTRE-SW
Common
DU GOT
HMIs
GT Works
Converter for old projectsDocumentation functionImproved help functionDebug functionProject managerTemplates and tool barExpanded librariesSimulation Tools
HMIs
GOT Software
Compatibility A900GOT and A870GOT
Compatibility FX-50DU-TKS and F940GOT
GOT800 GOT800 screen datascreen data Convertor
GOT900 GOT900 screen screen datadata
FX-50DU-TKSFX-50DU-TKSFX-50DU-TKSFX-50DU-TKS F940GOTF940GOTF940GOTF940GOTFX-DU-WIN-SW
HMIs
Questions?
Human Machine InterfacesHuman Machine Interfaces
HMIs
Human Machine InterfacesHuman Machine Interfaces
HMIsHMIs