242
1- AIR/WATER HEATING/COOLING PUMP
2-G2 HEAT EXCHANGER
3-
4-B-100 DIGITALLY CONTROLLED ELECTRIC POOL HEATER
5- ELECTRIC HEATER SERIES "ULTRA"
6- POOL SMART
7- PLATE HEAT EXCHANGERS FOR HEATING & COOLING LIQUIDS
8- AQUA INDOOR POOL DEHUMIDIFIER
9- AQUA POOL DEHUMIDIFIERS WITH HEATING & COOLING FUNCTION
EVOLUTION ELECTRIC POOL HEATER
244
246
247
248
249
249
250
252
253
1- AIR/WATER HEATING/COOLING PUMP
• Extend your swim season in comfort...
The AQUA heat pump can turn your backyard pool investment into resort style
living almost year round. Get the most out of your pool by keeping it comfortable
and open longer.
An AQUA heat pump will give you the flexibility of warming your pool water in the
winter months. Your backyard evening events are rarely slowed down by cool
weather when you have an AQUA heat pump on duty.
• Reversing Valve
Heat-Cool units have a unique reversing valve that allows the he pump to cool the
pool water during the hot summer months to pleasant temperatures allowing you
to swim comfortably and enjoy cool water in extremely hot temperature.
244
He
ati
ng
-Co
oli
ng
Un
its
• Set it and forget it
The AQUA heating/cooling unit allows you to set your desired temperature of the pool during all the year and it will simply do the rest
without the need for any additional settings, comes with a unique LED control.
• Maximize your return...
The heating/cooling unit of AQUA can cut your operating cost comparing to combustion oil or gas boilers & electrical heaters to up to
80%, not to mention the easy installation and environment friendly.
• Long operating life
Using high quality equipment and advance technology of PVC water heat exchanger that withstands the abuses of harsh pool
chemistry and erosion, the AQUA spiral exchanger also helps reduce deposit build-up.
FEATURES:
• Phase monitor: Protects the compressor in case of phase loss or inversion.
• Defrosting: The unit defrosts the evaporator when the ventilator is activated.
• Scroll Compressor for bigger sizes: For silent and efficient functioning.
• Easy access electrical hookup.
• Stainless steel hardware won't rust or deteriorate.
• UV resistant paint coated shell resistant to rust.
• Hydraulic circuit with new design flow switch in the water inlet, connections in PVC or PPR threaded fittings.
• Made to perform in Extreme conditions.
• New quiet fan design.
• Spiral heat exchanger in plastic shell (new design) for top performance.
Swimming Pool
Technical room
By-pass Chemical treatment
Heat pump
Blowing
245
71
W H
L
CODE
HEATING CAPACITY
WATER PRESSURE DROP
OPERATING TEMPERATURE RANGE
WEIGHT NET/ GROSS
NET DIMENSIONS (L / W / H)
REFRIGERANT
WATER FLOW
POWER INPUT
HEAT EXCHANGER SHELL
HEAT EXCHANGER SHELL
NOISE LEVEL
WATER CONNECTION
AMPERE
COOLING CAPACITY
POWER INPUT
EFFICIENCY
FAN COMPRESSOR
FAN POSITION
PH-02620 PH-02630 PH-02640 PH-02650 PH-02660 PH-02710
BTU/H
BTU/H
KW/H
KW/H
KW
A
dB(A)
m³/h
kPa
mm
kg
COP
V/Ph/Hz
mm
32500
9.5
5.5 5.5 5.5 5.5 5.5
ROTARY*1 SCROLL*1 SCROLL*1 SCROLL*2
UPWARDS UPWARDS UPWARDS UPWARDS UPWARDS UPWARDS
45000 55000 68000 85300 136000
220/1/50 380/3/50 380/3/50 380/3/50380/3/50 380/3/50
48 51 51 57 57 61
50 63
2.7 8.2~ 3.8 11.4~ 4.6 14~ 6 17.2~ 7.2 21.5~ 11.5 34~
10 10 10 1212 15
695/655/740 710/710/960 710/710/960 710/710/960 710/710/960 1450/705/1065
71/78 105/115 110/120 114/125 135/145 250/270
PVC/PPR
TITANIUM TITANIUM TITANIUM TITANIUM TITANIUM TITANIUM
PVC/PPR PVC/PPR PVC/PPR PVC/PPR PVC/PPR
C° 5 53~ 5 53~ 5 53~ 5 53~ 5 53~ 5 53~
R22 R22 R22 R22 R22 R22
13.2 16 20 25 40
32800 41000 51000 65000 102000
9.6 12 15 19 30
2.4 2.9 3.64 4.55 7.3
4.3 5.2 6.4 8.1 12.9
CODE
HEATING CAPACITY
WATER PRESSURE DROP
OPERATING TEMPERATURE RANGE
WEIGHT NET/ GROSS
NET DIMENSIONS (L / W / H)
REFRIGERANT
WATER FLOW
POWER INPUT
NOISE LEVEL
WATER CONNECTION
AMPERE
COOLING CAPACITY
POWER INPUT
EFFICIENCY
FAN COMPRESSOR
FAN POSITION
BTU/H
BTU/H
KW/H
KW/H
KW
A
dB(A)
m³/h
kPa
mm
kg
COP
V/Ph/Hz
mm
5.5 5.5 5.5 5.5 5.5 5.5
SCROLL*7 SCROLL*6 SCROLL*5 SCROLL*4 SCROLL*3 SCROLL*2
UPWARDS UPWARDS UPWARDS UPWARDS UPWARDS UPWARDS
C° 5 53~ 5 53~ 5 53~ 5 53~ 5 53~ 5 53~
R22 R22 R22 R22 R22 R22
PH-02713 PH-02715 PH-02720 PH-02730 PH-02740 PH-02750
170000 273000 358000 460000 540000 615000
50 80 105 135 158 180
126000 205000 266000 341000 399000 460000
265/285 510/570 610/670 820/870 910/950 1390/1420
1450/730/1300 2150/764/1330 2150/764/1330 2200/1615/1355
15 20 20 24 28 30
14.3 50~ 23 60~ 30 90~ 39 116~ 45.3 136~ 52 154~
63 90 90 11063 75
61 64 64 65 65 65
380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50
37 60 78 100 117 135
9.1 14.5 19.1 24.6 28.8 32.7
16.1 25.6 33.7 43.5 50.9 57.8
• Note: Refrigerant gas can be changed to R407C or R410 as per request.
HEAT EXCHANGER SHELL
HEAT EXCHANGER
PVC/PPR PVC/PPR PVC/PPR PVC/PPR PVC/PPR PVC/PPR
TITANIUM TITANIUM TITANIUM TITANIUM TITANIUM TITANIUM
2200/1615/1355 2200/1615/1355
24000
7.1
1.73
7.86
5.5
SCROLL*1 SCROLL*1
50 50 50 50
Swimming Pool
PumpFilter
Heat Exchanger
Pump
Boiler
13
0
'L1' WITH UNIONS
'L2' WITOUTH UNIONS
He
ati
ng
-Co
oli
ng
Un
its
2- G2 HEAT EXCHANGER
• • Robust, durable construction.• Titanium tube bundle.• 316 Stainless Steel shell with special polyamide fittings• Wall mountable (bracket supplied)• Available with fully equipped Analogue or Digital control (optional).• The heat exchanger construction gives a vast heat transfer surface area, consisting of a densely populated multi-tubular bundle, secured by the uniquely designed polyamide- rubber tube sheet.• The heat exchanger shell is constructed from BS 316 Stainless Steel enclosed by a rigid thermal shell for enhanced insulation of the primary (HOT) water, enabling even greater heat transfer; this is capped at each end with primary and secondary moulded fittings manufactured from specially formulated polymer alloy material.• The standard G2 heat exchanger is supplied complete with: - 2 x 1” male/male Brass Primary connections. - 1 x 1” Non-Return Valve. - Titanium thermostat pocket. - 1 x Blanking Cap and Gasket (for non-thermostat side).• The G2 Heat Exchanger has been designed to allow the installation engineer to select which way to plumb the primary and secondary water to achieve maximum thermal gain; this is achieved by routing the primary (HOT) flow in an opposing direction to the secondary (POOL) water.• The G2 heat exchanger is installed in the pool filtration circuit from which water passes through the tube side of the exchanger. Water from the primary heating circuit flows counter-current through the shell side of the exchanger, heating the swimming pool water. Ideal for use with gas or oil fired boiler circuits, solar panels, heat pumps or chillers.• Tube bundle: Pure titanium.• Water connections: - Primary (HOT) 1” BSP male (brass fittings supplied). - Secondary (POOL): 1.5” or 50-mm NB adapters for connection to PVC or ABS pipe.• Working pressure: 4 bar maximum.
The G2 Heat Exchanger is manufactured from top quality components and materials.
246
CODE
G2-HE-30T
G2-HE-49T
G2-HE-85T
G2-HE-122T
PRIMARY(HOT)FLOW
101014161617171717191919
m³1.11.31.31.61.82.22.42.73.23.84.24.6
kPa6.16.86.87.78.39.6
11.312.914.718.320
21.1
557
9.29.29.8
10.610.610.612.612.612.6
KW KW KW KW KW KW KW
T15°C
T20°C
T30°C
T40°C
T50°C
T60°C
T70°C
91011131416222628333638
161820252833404649687073
111315182022283234434852
202326343844536064758995
26313441455264737793
108116
303441505564758290
108126137
3339465662738189
102120143156
T = temperature difference between Priamry (HOT) and Secondary (POOL)
DIMENSIONS
L1
STANDARDPOWEROUTPUT
L2
PRIMARY(HOT)
HEAD LOSS
SECONDARY (POOL)FLOW
m³
SECONDARY(POOL)
HEAD LOSS
m³
30 kW(102K BTU)
49 kW(167K BTU)
85 kW(290K BTU)
122 kW(416K BTU)
540
710
840
1000
426
596
726
836
L
mm
L
mm
247
71
3- EVOLUTION ELECTRIC POOL HEATER
• Fully equipped and pre-wired including a super sensitive and reversible flow switch,
allowing water input from either direction.
• Complete with a control thermostat, safety thermostat and integral contactor relay.
• Very easy to install, requiring only final connection to a mandatory separate RCD.
• Fitted with 1½" BSP female threaded adapters for easy connection to all pipework.
• Supplied with hose tail adapters for connection to flexible pipework, and heater
sizes 12kW through to 18kW are also supplied with 1½" BSP unions for connection
to rigid pipework.
• Suitable for use with chlorinated pools & are NOT suitable for salt water pools.
• Main Tank Stainless Steel BS316, available with pure Titanium upon request.
• Heating elements: Incoloy 825 or pure titanium on request.
• Control thermostat 0ºC - 40ºC with 1.5ºC differential safety thermostat 50ºC.
• Manual reset minimum flow requirement 1,000-litres per hour Maximum Flow
Velocity 13,000-litres per hour
CODE POWER
kw
3
6
9
12
15
18
PHS-030-EV
PHS-060-EV
PHS-090-EV
PHS-120-EV
PHS-150-EV
PHS-180-EV
CODE POWER
kw
6
9
12
15
18
24
PHT-060-EV
PHT-090-EV
PHT-120-EV
PHT-150-EV
PHT-180-EV
PHT-240-EV
40
0V
Th
ree
Ph
ase
23
0V
Sin
gle
Ph
ase
L
24
0
160
WEIGHT
kg
VOLUME
m³
PACKINGWEIGHT
kg
VOLUME
m³
1
1
1
1
1
1
PACKING
3.5
4
4.5
5
5.5
6
0.04
0.04
0.04
0.04
0.04
0.04
462
462
462
462
592
592
1
1
1
1
1
1
4
4.5
5
5.5
6
6.5
0.04
0.04
0.04
0.04
0.04
0.04
462
462
462
462
592
592
Swimming Pool
Pump Filter Evolution Electric Pool Heater
Val
ve
Wat
er
Tre
atm
en
t
Swimming Pool
Pump Filter B-100 Electric Pool Heater
Val
ve
Wat
er
Tre
atm
en
t
248
He
ati
ng
-Co
oli
ng
Un
its
4- B-100 DIGITALLY CONTROLLED ELECTRIC POOL HEATER
CODE POWER
kw
24
30
36
45
54
60
72
PH-30-B100
PH-36-B100
PH-45-B100
PH-54-B100
PH-60-B100
PH-72-B100
PH-24-B100
• Designed for ultimate safety and market leading reliability.
• With two conductors per element bank, cascade wired for ultimate safety.
• All element banks have timers for staged energizing: only a maximum of 24 kW
will be energized at any one time.
• Perfect for use on larger pools. Available in outputs from 24-72 kW.
• Multiple heaters can be installed in parallel to achieve greater outputs.
• Supplied fully equipped and pre-wired to ensure easy installation.
• Heating elements: Incoloy 825 or pure titanium on request.
• Flow tube: stainless steel BS-316 or pure titanium on request for total protection
against corrosion.
• Flow Switch: to protect equipment when flow stops.
• Multi point temperature detection: For accurate and safe control of the heating
process.
• Anti cycle delay protection: Prevents the heater from 'cycle' switching to ensure
component life is maximized.
• Indication lamps: Provide clear and easily understandable display of the heaters
status.
• Mounting brackets: Ensure the heater can be easily wall or base mounted
• Unique case design: Gives easy technician access for connection, inspection and
component replacement.
WEIGHT
kg
VOLUME
m³
PACKING
1
1
1
1
1
1
1
23
24
25
26
27
28
29
0.1
0.1
0.1
0.1
0.1
0.1
0.1
700
434 280
Ø 63 Ø 53
39
9
CODE
PH-SMART
• An intelligent pool control system that allows the control and maintenance of the
pool to the perfect temperature as economically as possible.
• Complete control solution for: Filtration pumps, electric heaters, heat exchangers
and heat pumps to the filtration system and boiler.
• Accurate temperature control to 0.5°C.
• Diagnostic display.
• Fully programmable with timed control.
• User defined duel set points to utilize off-peak electricity rates.
• Supplied with flow switch, temperature sensor probe pre-fitted in custom T-piece
with 63mm solvent weld connections (50mm reducers are also supplied), for simple
integration into any pool technical facility.
6- POOL SMART
• Fitted with two supply contactors to stop heater damage if the first contactor welds
its contacts.
• Highest quality elements with a protective coating against corrosion.
• Heater tank constructed of no corrosive s. steel with 2” unions.
• Precise pool temperature setting dial.
• Fitted with safety flow switch and over temperature reset.
• Ideal for connection to lower tariff off peak electricity supply.
• Three Phase 380V.
CODE AMPEREPOWER
AKW
9
14
18
27
36
55
73
82
91
109
6
9
12
18
24
36
48
54
60
72
UL- 60-
UL-090-T
UL-120-T
UL-180-T
UL-240-T
UL-360-T
UL-480-T
UL-540-T
UL-600-T
UL-720-T
0 T
5- ELECTRIC HEATER SERIES "ULTRA”
249
71
WEIGHT
kg
VOLUME
m³
PACKING
1
1
1
1
1
1
1
1
1
1
32
34
36
38
40
42
44
46
48
50
0.10
0.10
0.15
0.20
0.20
0.25
0.25
0.25
0.25
0.25
WEIGHT
kg
VOLUME
m³
PACKING
1 2 0.02
7- PLATE HEAT EXCHANGERS FOR HEATING & COOLING LIQUIDS
• Ideal for heating ,cooling, heat-recovery, condensing and evaporation processes.
• High overall heat transfer coefficient for efficient heat transfer.
• Compact design gives maximum surface area to material volume without compromising
mechanical robustness.
• Low installation cost.
• Easy dismantling for rapid cleaning.
• High performance with low hold-up volume.
• Versatile, modular design.
• Plate and gasket materials available to suit most fluid types
• Standard units available from stock: 100-kW to 819-kW for heating applications; 53-kW
to 397kW for cooling applications.
• Short lead-time custom build service.
• The Plate heat exchangers comprise an epoxy coated steel frame consisting of one
removable and one fixed cover fitted with top and bottom plate hangers.
• The fluid connections are heavy gauge, stainless steel, male threaded nozzles welded
into the front cover.
• Flanges are available on request.
• The heat transfer plates are corrugated in a herringbone pattern with port holes for the
passage of the two fluids and have clip on re-usable seals.
• Plate materials available: Titanium (standard), BS 316 Stainless Steel ,Hastelloy alloy,
Nickel.
• Seal materials available: EPDM (standard), HNBR, NBR, NEOPRENE.
• Maximum working pressure: 0.6-MPa.
• Maximum operating temperature: 150°C.
53
66
92.7
125.9
149
172.3
192.1
215
231.8
244.8
265.2
295.8
326.4
357
377.4
397.8
0.04
0.04
0.04
0.04
0.04
0.04
0.04
0.04
0.04
0.15
0.15
0.15
0.15
0.15
0.15
0.15
TI
TI
TI
TI
TI
TI
TI
TI
TI
TI
TI
TI
TI
TI
TI
TI
PHE-100
PHE-140
PHE-180
PHE-240
PHE-290
PHE-330
PHE-370
PHE-410
PHE-450
PHE-500
PHE-550
PHE-610
PHE-670
PHE-730
PHE-780
PHE-820
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
543
543
543
543
543
543
543
543
543
971
971
971
971
971
971
971
250
250
250
250
250
250
250
250
250
360
360
360
360
360
360
360
664
664
664
664
664
664
664
664
664
910
910
910
910
910
910
910
Cooling Performance Table (water/water)
45,700
56,900
79,700
108,200
128,200
148,400
165,200
185,100
199,400
240,300
228,000
254,300
280,600
307,000
324,500
342,000
18
22
30
40
47
54
60
67
72
26
28
31
34
37
39
41
PROCESS CIRCUIT (31°C/26°C)
CODE
PLATE MATERIALSUFFIX
Tita
nium
316
S.St
eel
TRANSFER
kcalkW
AR
EAO
F P
LATE
m²
NU
MB
ERO
F P
LATE
S
FLOW
m³/h
PRESSUREDROP
kPa
CONN.
BSPT
COLD CIRCUIT (8°C/15°C)
FLOW
m³/h
PRESSUREDROP
kPa
CONN.
BSPT H W D
DIMENSIONS
6.0
7.5
10.5
14.3
16.8
19.5
21.7
24.3
26.2
27.6
29.9
33.4
36.8
40.3
42.6
44.9
42
42
42
42
42
42
42
42
42
40
40
40
40
40
40
40
1½"
1½"
1½"
1½"
1½"
1½"
1½"
1½"
1½"
2½"
2½"
2½"
2½"
2½"
2½"
2½"
83
10.4
14.6
19.9
23.5
27.2
30.3
34.0
36.6
38.7
41.9
46.7
51.6
56.4
59.6
62.8
45
45
45
45
45
45
45
45
45
42
42
42
42
42
42
42
1½"
1½"
1½"
1½"
1½"
1½"
1½"
1½"
1½"
2½"
2½"
2½"
2½"
2½"
2½"
2½"
250
He
ati
ng
-Co
oli
ng
Un
its
102
140
178
242
287
332
370
414
446
504
546
609
672
735
777
819
0.04
0.04
0.04
0.04
0.04
0.04
0.04
0.04
0.04
0.15
0.15
0.15
0.15
0.15
0.15
0.15
TI
TI
TI
TI
TI
TI
TI
TI
TI
TI
TI
TI
TI
TI
TI
TI
PHE-100
PHE-140
PHE-180
PHE-240
PHE-290
PHE-330
PHE-370
PHE-410
PHE-450
PHE-500
PHE-550
PHE-610
PHE-670
PHE-730
PHE-780
PHE-820
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
543
543
543
543
543
543
543
543
543
971
971
971
971
971
971
971
250
250
250
250
250
250
250
250
250
360
360
360
360
360
360
360
664
664
664
664
664
664
664
664
664
910
910
910
910
910
910
910
Heating Performance Table (water/water)
88,440
120,600
153,500
208,300
246,700
285,000
318,000
356,300
383,700
433,300
469,500
523,600
577,800
632,000
668,000
704,200
18
22
30
40
47
54
60
67
72
26
28
31
34
37
39
41
PROCESS CIRCUIT (31°C/26°C)
CODE
PLATE MATERIALSUFFIX
Tita
nium
316
S.St
eel
TRANSFER
kcalkW
AR
EAO
F P
LATE
m²
NU
MB
ERO
F P
LATE
S
FLOW
m³/h
PRESSUREDROP
kPa
CONN.
BSPT
COLD CIRCUIT (8°C/15°C)
FLOW
m³/h
PRESSUREDROP
kPa
CONN.
BSPT H W D
DIMENSIONS
4.0
5.6
7.0
9.6
11.3
13.1
14.6
16.3
17.6
19.9
21.5
24.0
26.5
29.0
30.6
32.2
38
38
38
38
38
38
38
38
38
36
36
36
36
36
36
36
1½"
1½"
1½"
1½"
1½"
1½"
1½"
1½"
1½"
2½"
2½"
2½"
2½"
2½"
2½"
2½"
9
11
15
20
24
27
30
34
36
40
43
48
53
58
61
64
47
47
47
47
47
47
47
47
47
45
45
45
45
45
45
45
1½"
1½"
1½"
1½"
1½"
1½"
1½"
1½"
1½"
2½"
2½"
2½"
2½"
2½"
2½"
2½"
251
71
252
He
ati
ng
-Co
oli
ng
Un
its
• Clear Windows, Dry Walls: No more foggy windows or condensation on walls in the pool
room with AQUA dehumidifiers preserve the construction integrity and gives a pleasant
feeling to the room occupants.
• Simple Installation: Can be free standing or remote. It is also duct ready, the control can
be easily made in a 220 volts wiring.
• Quality Construction & Reliability: AQUA dehumidifier comes in white coated anti-
humidity paint or in stainless steel body, Digital LCD controller & gas pressure gauge. The
unit is covered under a 5 year warrantee.
• Low Electrical Cost: AQUA dehumidifier utilizes a refrigeration system that requires a
smaller electrical load.
• Humidity Control: Stabilize room conditions through dehumidification, this reduces the
maintenance cost of the room and gives a very pleasant environment to the pool room.
• Indoor Pool Room Heating: Recovering energy from the dehumidification process will
often heat an entire pool room for the cost of operating the dehumidifier alone.
• Indoor Pool Room Cooling: An optional remote condenser will allow the DCA system to
cool the pool room during the warm months.
• Easy to Maintain: The AQUA dehumidifier system is a closed loop system with nothing to
oil or lubricate. Simple return air filter maintenance is all that is needed.
CODE
L/H
DH-2.0
DH-3.0
DH-4.0
DH-6.0
DH-15.0
DEH
UM
IDIF
YIN
GCA
PACI
TY
2
3
4
6
15
AP
PLI
CA
BLE
TEM
PER
ATU
RE
RA
NG
E
POWERSUPPLY
1Ø 220
1Ø 220
1Ø 220
1Ø 220
1Ø 220
50/60
50/60
50/60
50/60
50/60
V HZ
5°C - 40°C
5°C - 40°C
5°C - 40°C
5°C - 40°C
5°C - 40°C
Note: For Remote Installation (Option 3); add "-RI" to the code. For example: DH-4.0-RI
8- AQUA INDOOR POOL DEHUMIDIFIER
AQUADehumidifier
Option 1: Installation in humid area with no ducting.
Option 2: Installation in humid area with ducting and ventilation.
Direct Warm & Dry AirToward Window Glass
Direct Warm & Dry AirToward Window Glass
Option 3: Remote installation area with ducting and ventilation.
RemoteController
AQUADehumidifier
AQUADehumidifier
W
Ø 154
H
D
AIR
FLO
W
m³/h
PROTECTION&
CONTROL DEVICE
UNITDIMENSIONS
(mm)
H W D
549
549
665
766
1800
604
700
753
913
800
371.5
371.5
416
416
460
750
900
1200
1500
3700
PO
WER
INP
UT
0.73
1.40
1.41
1.50
3.50
High pressure protectionLow pressure protection
Over-amps protectionPhases protectionOver heat proction
Auto. adjusting conditionssystem
Running pressure display
DIS
CH
AR
GE
DIA
MET
ER
INCH
3/8
3/8
3/8
3/8
3/8
kW
R-2
2(R
40
7C
/R1
34
a)
Sett
ing
Ra
nge
20
%R
H-9
0%
RH
MO
ISTU
RE
CO
NTR
OLL
ER
REF
RIG
ERA
NT
PAC
KIN
G
WEI
GH
T
VO
LUM
E
m³kg
1
1
1
1
1
0.20
0.20
0.25
0.30
0.60
253
71
• Humidity Control: Stabilize room conditions through dehumidification.
• Indoor Pool Room Heating: Recovering energy from the dehumidification process
will often heat an entire pool room for the cost of operating the dehumidifier alone.
• Indoor Pool Room Cooling: An optional remote condenser will allow the DCA system
to cool the pool room during the warm months.
• Pool Water Heating: An optional pool water heating coil contained as part of the
dehumidifier can heat the pool water under certain conditions.
• Supplemental Pool Room Heating: An optional electric or gas duct heater may be
added to the DCA system to add additional room heating when needed.
• Easy to Maintain: The AQUA Dehumidifier is a closed loop system with nothing to
oil or lubricate. Simple return air filter maintenance is all that is needed.
• Installation: The AQUA Dehumidifier is typically a ducted system similar to the
heating and cooling presently in your home.
9- AQUA POOL DEHUMIDIFIERS WITH HEATING & COOLING FUNCTION
Out Dry Air
Return Wet Air
Pool Water
ExhaustDirtyAir
InletFresh
Air
Return Air Pipe
ReturnWater PipeReturnWater Pipe
OutletWaterPipe
Ret
urn
Air
Pip
e
Air
Ou
tlet
Pip
e
• Room hygrostat and thermostat.• Automatically switches mode from heat to cool.• Optional digital controller with display.
Swimming Pool Surface - m²
QUICK SELECTION GUIDE:
0 25 50 75 100 125 150 175 200 225 250 275
AD-75
AD-60
AD-30
AD-15
• Swimming pools• Spas• Shower rooms• Gymnasium• Work shops
• Warehouses• Cellars• Archives• Museums
CODE RECOMMENDED ROOM SIZE
50 - 73 m³
APPLICATION AREAS
AD-15
AD-30
AD-60
AD-75
• Larger private pools• Commercial pools• Commercial spas• Warehouses• Archives• Test rooms• Production areas
100 - 150 m³
200 - 300 m³
300 - 450 m³
CODE
25
51
80
120
HEA
TIN
GC
APA
CIT
Y
CO
OLI
NG
CA
PAC
ITY
DIM
ENSI
ON
S(L
/W/H
)
WEI
GH
T
KW KW m kg
17.8
39
78
85
RAT
E C
UR
REN
T
RAT
E V
OLT
AG
E
AD-15
AD-30
AD-60
AD-75
FAN MOTOR
PO
WER
KW
QU
AN
TITY
STYL
E
2
2
2
2
1.5
1.5
3
4 CEN
TRIF
UG
AL
FAN
NO
ISE
LEV
EL
dB
60
60
60
60
9
9
9
10
380
380
380
380
50/60
50/60
50/60
50/60
15
30
60
75
L/h
DEH
UM
IDIT
YV
OLU
ME
AIR
VO
LUM
E
3700
7500
15000
17000
m³/h
AIR
PR
ESSU
RE
PA
400
400
400
400
PO
WER
KW
QU
AN
TITY
BR
AN
D
1
2
4
4
4.4
4.4
4.4
5
CO
PEL
AN
D
COMPRESSOR
R4
07
C, R
41
7A
REFRIGERANT
TYP
E
WEI
GH
T
kg
3.6
3.6
3.6
4.2
V
RAT
EFR
EQU
ENC
Y
HEA
T EX
CH
AN
GER
WAT
ER P
RESS
URE
RESI
STA
NCE
RAT
E P
RES
SUR
E
OU
TLET
WAT
ERTE
MP
REA
TUR
E
PIP
E SI
ZE
WAT
ER F
LOW
Hz
TITA
NIU
M,
STA
INLE
SS S
TEEL
Mpa Mpa °C mm m³/h
WAT
ER -
CO
OL
OU
TDO
OR
CO
ND
ENSO
R
0.01
0.01
0.015
0.015
0.4
0.4
0.4
0.4
35
& 4
5
50
50
63
63
5
10
20
25
660
1000
1600
1700
3.5/1/1.2
3.5/1/1.2
4/1.5/1.2
4/1.5/1.2
AQUAPool Dehumidifier
Recommended