ASSEMBLY AND INSTALLATION INSTRUCTIONS
NOTES: 1. Before installing, consult local electrical codes for wiring and grounding requirements. 2. READ AND SAVE THESE INSTRUCTIONS.
H0138
Hardware Package (included):
WARNING: TO AVOID RISK OF ELECTRICAL SHOCK, BE SURE TO SHUT OFFPOWER WHILE INSTALLING OR SERVICING THIS FIXTURE.
150119
Green Grounding Screw (H)
Wire Nut (I)Canopy (A) Loop Lock (G)
Chain (J)
Hex Nut (D)Washer (C)
Glass Drop d1PC
Glass Drop a8PCS
Glass Drop b12PCS
Nipple-a (E) Nipple-b (F)Top Loop (B)
Collar (K) Clamp (L) Connector (M)
Glass Drop c12PCS
Clamp(L)
Set ScrewSafety Steel Cord
Outlet Box
Nipple-b(F)Fixture Wire
Fixture Grounding Wire
Nipple-a(E))
Connector(M)
Set Screw
Ceiling Structura Member
House Supply And Grounding Wires
Wire Nut
3/4" Hole Big Metal Pad(N)Lock Nut(P)
Top Loop(B)
Loop Lock(G)
Loop Lock(G)
Loop
Top Decorative Cup
Bottom Decorative Cup
Chain(J)
Canopy(A)
Collar(J)
Flat Pad(O)
Bulb Type A Max.100W (not included)
Socket Fixer
Glass Shade
Glass Drop a
Glass Drop c
Glass Drop b
Glass Drop b
Glass Drop c
Glass Drop d
SocketGlass Bracket
Threaded Pipe-2
Finial
Fixture
Bottom CoverSlot
Hex NutWasher
CouplingConnector
Top CoverSlot
MetalPad
Hex NutThreaded Pipe-1Coupling
Upper Arm
Middle Arm
Socket RingSpacer
Hex Nut
Big Metal Pad(N) Flat Pad(O) Lock Nut (P)
Set ScrewClamp
Knot
Safety SteelCord
Fig.2
Nipple(-a)
Nipple(-b)
Set Screw
Connector1/2"
1/2"
Fig.1
150119
1. This heavy fixture requires a means of support independent of the outlet box. Remove the knockout slug from the inside top center of the outlet box, and then drill a 3/4 inch diameter hole through the ceiling structural member. The fixture will be installed directly onto the ceiling structural member. Before starting assembly, it is important to make sure that the ceiling structural member can at least support four times weight of the fixture. We recommend the consultation of a qualified electrician due to the complexity of this installation.
2. Adjust the arms of the fixture according to the drawing of the package. Important: a. The arms of each tier (upper, middle) should be positioned with equal distances between them. b. The arms should be fixed securely.
3. Attach the threaded pipe-1 to coupling, secure it with hex nut. NOTE:Depth of threaded pipe-1 may need to be adjusted to properly fit top cover, top decorative cup and loop. 4. Slip the top cover through the threaded pipe-1 to fixture and the metal pad engages into the slots of top cover.
5. Slip the top decorative cup to top cover, secure it with hex nut. Then screw the loop to threaded pipe-1. Thread fixture wires through threaded pipe-1, top cover, top decorative cup, hex nut and threaded end of loop first.
6. Attach the threaded pipe-2 to coupling, secure it with a washer and hex nut. NOTE:Depth of threaded pipe-2 may need to be adjusted to properly fit bottom cover, bottom decorative cup and finial.
7. Slip the bottom cover through the threaded pipe-2 to fixture and the connectors engage into the slots of bottom cover.
8. Slip the bottom decorative cup to bottom cover, secure it with hex nut. Then screw the finial to threaded pipe-2.
9. Install the glass drops(a,b,c,d) as shown in diagram.
10. Connect the chain: - Determine length of chain needed to achieve desired fixture height. (To remove excess chain section, use plier to bend link open.) - Weave the fixture wires through the chain, collar and canopy.
11. Secure the top loop to the nipple-b pipe.
12. Screw the connector to other end of nipple-b about 1/2 inch, and then secure it with a set screw at side of connector. (See Fig.1)
13. Thread the fixture wires and the fixture grounding wire through the top loop, nipple-b and pull them out from bigger hole at side of connector.
14. Screw one end of nipple-a into the other end of the connector about 1/2 inch, and then secure it with a set screw from the side of the connector. (See Fig.1)
15. Thread the safety steel cord through the collar, canopy, top loop, nipple-b, connector and nipple-a.
16. Connect one end of the chain to the loop using a loop lock.
17. Connect the other end of the chain to the top loop using the other loop lock.
18. This step requires three people at least to proceed. Two people hold the fixture, the other one inserts the safety steel cord, and nipple-a through the drilled hole of the ceiling structural member, and then secures it with a big metal pad and lock nut.
19. Thread the safety steel cord through the flat pad, and then through one hole of the clamp. Make a knot, and then pull it out from the other hole of the clamp. Pull the cord straightly and attach the flat pad toward the top end of nipple-a, and then attach the clamp toward the flat pad. Tighten the safety steel cord with two set screws from two ends of the clamp. (See Fig.2) Note: The safety steel cord provides a back up system of the installation fixture. It's essential that the safety steel cord is properly installed.
Turn off the power at fuse or circuit box.
Installation Steps
150119
Turn on the power at fuse or circuit box.
The following parts are available for re-order if damaged or missing.
Spare Parts List:
Assembly Kit 5298MM (1 SET)
Glass Shade9700AB(12PCS)
A
B
Glass Drop d5073GS(1PC)
Glass Drop a5069GS(8PCS) Glass Drop b
5071GS(12PCS) Glass Drop c5070GS(12PCS)
20. Pull out the source wires from the outlet box. Make wire connections using wire nuts as follows: ---Connect the smooth-coated wire (marked) from the fixture to the black wire from the power source. ---Connect the ribbed-coated wire (unmarked) from the fixture to the white wire from the power source. ---Connect the fixture grounding wire to the house grounding wire with a wire nut. Carefully put the wires back into the outlet box.
21. Attach the canopy to the ceiling: insert the top loop through hole, then secure by tightening collar.
22. Attach the glass shades to the glass brackets, secure them with the spacers and socket rings, using supplied socket fixer
23. Install bulbs (not included). See relamping label at socket area or packaging for maximum allowed wattage.
Green Grounding Screw (H)
Wire Nut (I)
Canopy (A)
Loop Lock (G)
Chain (J)
Hex Nut (D)Washer (C)
Nipple-a (E) Nipple-b (F)
Top Loop (B)
Collar (K) Clamp (L)
Connector (M) Big Metal Pad(N) Flat Pad(O) Lock Nut (P)
A: 45-1/2"
B:53"