8/14/2019 Guntner MAN
1/28
Ammonia Industrial Applications 1-47 Tons
NH3Evaporator
MAN> > U S E D F O R S M A L L T O M E D I U M I N D U S T R I A L A M M O N I A A P P L I C A T I O N S
M A N U FA C T U R E D W I T H S T A I N L E S S S T E E L T U B E S .
8/14/2019 Guntner MAN
2/28keep(s) your quality. www.guntnerus.com
keep(s) your quality
08.07
With seven decades of experience and commitment to total client satisfaction,
Guntner has earned a reputation as the global leader in heat exchange
technology. Supported by the best R&D engineers in the business, cutting-
edge technology, and eight manufacturing facilities around the world, Guntner
continues to break new ground in the demanding market of finned heat
exchangers for industrial refrigeration, HVAC, and process cooling applications.
Our high standards and dedication to society and the environment around
us have earned us the respect of the industry, and the privilege of long-term
relationships with our customers around the world.
The Global Leader
In Heat Exchange Technology
8/14/2019 Guntner MAN
3/28www.guntnerus.com keep(s) your quality.08.07
MPC
Guntner Product
Calculator
Guntner Product
Calculator
> > C A L C U L A T I O N S M A D E E A S Y W I T H O U R P R E C I S E M P C S O F T W A R E
With the Guntner product calculator MPC, we are able to offer you
more than just an overview of prices or the complete product range. This
thermodynamic selection program enables you to calculate your own
tailored selections based on precise and actual thermodynamics rather than
factors or multipliers. A team of experts stand by to guide you through the
selection process.
The program can be updated via the internet ensuring that you always have
the most exact and precise information for proper selection.
We recommend using Guntners Product Calculator for exact thermodynamic
calculations. Varying conditions such as refrigerants, humidity levels and
material combinations are all taken into account by the software to most
accurately select products to fit your specific needs.
The Guntner Product Calculator
8/14/2019 Guntner MAN
4/28keep(s) your quality. www.guntnerus.com 08.07
CASING: Corrosion resistant Aluminum (AIMg3), sea-water resistant, up to fan diameter 20 (500 mm). From
fan diameter 26 (650 mm) and larger; treated, painted
and corrosion resistant galvanized steel sheet casing.
All casings powder coated - color RAL 9003 (Signal
White) and suitable for all stringent food industry
applications.
Construction detail takes accessibility into account
and does not allow for tight spots. All parts are easily
accessible for service and cleaning purposes.
Fan orifices are optimized by the manufacturer to
ensure maximum efficiency, air throw and airflow. All
fans are individually compartmented within complete
tube sheets to allow for fan cycling for capacity control
and reduction of operating costs.
All hangers and fittings used for construction and
assembly are manufactured from stainless steel
304. Easily removable side panels, complete with
PVC handles for access to internal and electrical
components.
TRAY: Corrosion resistant Aluminum (AIMg3), sea-
water resistant, up to fan diameter 20 (500 mm). From
fan diameter 26 (650 mm) and larger; treated, painted
and corrosion resistant galvanized steel sheet casing.
Trays are powder coated color RAL 9003 (Signal White).
All trays are our unique fold down type and can be
either folded down or completely removed, if required,
for cleaning purposes.Sloped design of the tray for all
models ensures maximum and efficient drainage during
defrost cycle. Drain outlet connection PVC 1 1/4
larger models have two outlets (some smaller models
have a 3/4 outlet) NPT.
Standard Features of Construction
8/14/2019 Guntner MAN
5/28www.guntnerus.com keep(s) your quality.08.07
TUBE: All tubing, headers and connections are
manufactured from the highest quality 304 Stainless
steel 5/8 (15 mm) tubing.
Parallel, in-line, 1.969 x 1.969 (50 x 50mm) allows
for reduced air-side pressure drop through the coil.
Tubes are mechanically expanded to ensure mechanical
bonding, coupled with the best heat transfer efficiency
ratio from fin to tube.
Our proven floating coil with support tubes does
not permit the refrigerant carrying tubes to come into
contact with the tube / end plates, and eliminates
the risk of tube failure at the end plates. All coils
are pressure tested to 450 psig with dry air under
water, and shipped with a holding charge.
FINS: Aluminum fins with a corrugated pattern
provides enhanced air turbulence, guaranteeing contact
with all surface areas within the coil bundle. Die formed
finned collars, 100% drawn, are standard and result in
accurate fin spacings of 6.3, 3.6, 2.5 and 2.1 FPI (4, 7,
10 and 12mm).
All fins are manufactured with a continuous fin sheet
in order to reduce the risk of frost build up, air-side
pressure drops, dust, dirt and bacteria simplifying
any cleaning procedure.
COIL CIRCUITING: Each unit is specifically circuited
to optimize coil performance and capacity with a
low pressure drop (consult with selection software to
obtain best circuiting for each application). Horizontal
headers are standard for re-circulated and flooded
applications. For larger capacities, and vertical headers,
please consult with your local sales office. Standard coil
connections are manufactured from carbon black steel,
as per ASME B31.5 requirements.
FANS & MOTORS: External rotor axial fans are
standard for the entire range.
All motors are aluminum die cast, of the highest
efficiency, maintenance free, guaranteed a long life and
low noise levels.
Fan guards are galvanized steel and PVC coated. All
motors are of the draw through type.
Standard voltages include 230V and 460V for 60Hz
applications and 400V for 50Hz applications.
DEFROST: Air, electric, hot gas or water defrost are
standard options for all units (no electric or water
defrost for 4 and 5 fan units).
Electric heater elements are stainless steel sheathed and
fit directly into tubes within the coil bundle to provide for
enhanced heat transfer during the defrost cycle.
Elements are held in place with clips to prevent them
from moving during transport or operation.
ELECTRICAL: All fan motors are factory wired to
the junction box with single point connection (factory
installed jumpers can be removed for individual /
capacity control). All heater wiring is terminated within
a junction box for quick and simple field connections.
When heater circuit amperages are in excess of 48
amps, multiple circuits are provided in order to comply
with the NEC limitation of 48 amps per circuit.
DELIVERY & PACKING: All units are shipped crated,
and positioned to facilitate installation. Trays are
supplied separately in the same crate and must be
fitted to the unit after the unit is hung. For foot mount
options the tray is pre-fitted.
8/14/2019 Guntner MAN
6/28keep(s) your quality. www.guntnerus.com 08.07
CONSTRUCTION MATERIALS
The casing, tube sheets and tray are manufactured
with either 304 or 316 stainless steel.
Units are supplied standard with carbon steel black
pipe connections but can be ordered with either
stainless stee pipe, flanges (ANSI B16.5) or carbon
steel threaded connection (ASME B1.20).
Insulated pan (required by the USDA for certain food /
processing applications).
Epoxy coated aluminum or stainless steel (304 or
316) fins.
Choice of coil connection side.
Powder coated to color of your choice dependant on
quantity.
Re-heat coils separated from the cooling coil by an
air gap.
Variable fin spacings.
Foot mounts, or wall mount for all units.
Extended legs / foot mounts.
FANS AND MOTORS
Oversize motors for higher face velocities and / or
external pressures.
Two-speed, high efficiency or explosion proof motors.
Air throw unit / streamer factory fitted to fan outlet.
Fan orifice connections for air distribution socks.
Hinged fan panels.
Blow through option available on some models.
Optional Features
DEFROST OPTIONS
Water defrost pan add 4 to the unit height
(construction material will be consistent with casing
construction).
For low temperature applications, we recommend the
use of fan ring heaters (available in 230V and 460V).
For electric defrost - defrost termination and fan delay
thermostat are factory installed.
Heater limit thermostat installed and pre-wired.
Factory installed check valve between tray and coil for
hot gas defrost.
ELECTRICAL
No wiring.
All motors wired to common / individual non-fused
disconnect.
All motors wired to common fused disconnect with
thermal protection for each motor.
All motors wired to fused disconnect with single
starter and thermal protection for each motor.
Various wiring options are available please consult
with factory for an alternative to suit your specific
requirements.
8/14/2019 Guntner MAN
7/28www.guntnerus.com keep(s) your quality.08.07
MAN 080 .1 C/ 3 10 -H L
PRODUCT LINE
FAN DIAMETER
16 041 18 046
20 051
26 065
28 071
32 080
VOLTAGE
J 3/400/60
L 3/460/60
S 3/400/50
U 3/230/60
DEFROST
A AIR
E ELECTRIC
H HOT GAS
W WATER
FIN SPACING
4 4mm - 6.3 FPI
7 7mm - 3.6 FPI
10 10mm - 2.5 FPI
12 12mm - 2.1 FPI
NO. OF FANS
3
VINTAGE
Only for 065/071/080.1
ROWS DEEP
A= 4 RowsB= 5 Rows
C= 6 Rows
D= 8 Rows
NH3Evaporator MAN
UNIT
MODEL
FAN
FAN MOTORS- ELECTRICAL SPECIFICATIONS
FAN DIAMETER MOTOR RATINGS @ 3Ph/60Hz (EA.) SOUND
Power Level Guntner
mm inch Voltage HP rpm FLA dB (A) Spare Part No.
041 400 16460 1/6 1,130 0.5 65.5
VT01172U230 1/6 1,100 0.78 65.0
046 450 18 460 1/4 1,390 0.62 73.0 VT01173U230 1/4 1,270 1.1 70.5
051 500 20460 1/2 1,350 0.96 75.5
VT01175U230 1/3 1,210 1.65 73.0
065.1 650 26460 1/2 860 1.25 77.0
VT01177U230 1/2 790 2.2 74.8
071.1 710 28460 3/4 830 1.65 80.5
VT01179U230 1/2 750 2.9 78.5
080.1 800 32460 1 1/2 970 2.5 84.0
VT01180U230 1 910 4.3 82.5
8/14/2019 Guntner MAN
8/28keep(s) your quality. www.guntnerus.com 08.07
Performance Data: 1 Fan Models
MODEL
NO.
MAN
CAPACITIES COIL
Wet Frosted
Surface Area Tube Volume Fin
Spacing
Btu/hr
/F TD
Btu/hr
/F TD ft2 ft3 fpi
041A/14- 1,398 1,121 310 0.19
6.3
041B/14- 1,868 1,323 387 0.26
046A/14- 2,434 1,629 496 0.26
046B/14- 2,829 2,255 621 0.34
051B/14- 3,792 2,692 776 0.41
065.1A/14- 5,026 3,877 1,103 0.63
065.1B/14- 6,672 4,953 1,379 0.75
071.1A/14- 6,761 5,290 1,447 0.78
071.1B/14- 8,833 6,741 1,810 1.01
080.1A/14- 9,814 6,575 1,967 1.08
041A/14- 1,398 1,121 310 0.19
3.6
041B/14- 1,868 1,323 387 0.26
046A/14- 2,434 1,629 496 0.26
046B/14- 2,829 2,255 621 0.34
051B/14- 3,792 2,692 776 0.41
065.1A/14- 5,026 3,877 1,103 0.63
065.1B/14- 6,672 4,953 1,379 0.75
071.1A/14- 6,761 5,290 1,447 0.78
071.1B/14- 8,833 6,741 1,810 1.01
080.1A/14- 9,814 6,575 1,967 1.08
080.1B/17- 8,048 6,578 1,447 1.31
080.1C/17- 9,875 7,475 1,737 1.60
041B/17- 1,214 1,002 228 0.26
2.5
041C/17- 1,532 1,267 274 0.26
046B/17- 2,049 1,472 366 0.34
046C/17- 2,543 1,624 438 0.41
051C/17- 3,080 2,552 548 0.52
065.1A/17- 3,416 2,611 649 0.63
065.1B/17- 4,286 3,531 811 0.75
065.1C/17- 5,387 4,112 974 0.90
051C/112- 2,208 1,837 335 0.52
051D/112- 3,161 2,642 447 0.67
065.1C/112- 3,821 3,192 596 0.90
065.1D/112- 5,251 4,382 794 1.19 2.1
071.1D/112- 7,207 5,775 1,043 1.53
080.1C/112- 7,124 5,900 1,062 1.60
080.1D/112- 9,541 8,123 1,416 2.09
8/14/2019 Guntner MAN
9/28www.guntnerus.com keep(s) your quality.08.07
MODEL
NO.
MAN
AIR FLOW ELECTRIC DEFROST
AirThrow
SoundPressure
LevelTotal Coil Tray Amp Draws*
@ 3/460/60 @ 3/230/60 @3/460 @3/230
cfm fpm cfm fpm ft db (A) kW W W A A
041A/14- 1,660 520 1,624 509 36 51 2.6 1,800 800 3.3 6.5
041B/14- 1,560 489 1,524 478 36 51 2.6 1,800 800 3.3 6.5
046A/14- 2,584 505 2,390 468 49 59 3.25 2,250 1,000 4.1 8.2
046B/14- 2,472 480 2,278 447 49 59 4 3,000 1,000 5.0 10.1
051B/14- 3,267 509 2,925 459 59 61 5 3,800 1,200 6.3 12.6
065.1A/14- 5,291 466 4,838 427 79 61 8.2 6,600 1,600 10.3 20.6
065.1B/14- 5,044 445 4,614 408 75 61 8.2 6,600 1,600 10.3 20.6
071.1A/14- 7,634 510 6,969 468 101 64 10.55 8,750 1,800 13.3 26.5
071.1B/14- 7,334 493 6,669 449 98 64 10.55 8,750 1,800 13.3 26.5
080.1A/14- 10,883 537 10,182 503 128 67 12.8 10,500 2,300 16.1 32.2
041A/14- 1,660 520 1,624 509 36 51 2.6 1,800 800 3.3 6.5
041B/14- 1,560 489 1,524 478 36 51 2.6 1,800 800 3.3 6.5
046A/14- 2,584 505 2,390 468 49 59 3.25 2,250 1,000 4.1 8.2
046B/14- 2,472 480 2,278 447 49 59 4 3,000 1,000 5.0 10.1
051B/14- 3,267 509 2,925 459 59 61 5 3,800 1,200 6.3 12.6
065.1A/14- 5,291 466 4,838 427 79 61 8.2 6,600 1,600 10.3 20.6
065.1B/14- 5,044 445 4,614 408 75 61 8.2 6,600 1,600 10.3 20.6
071.1A/14- 7,634 510 6,969 468 101 64 10.55 8,750 1,800 13.3 26.5
071.1B/14- 7,334 493 6,669 449 98 64 10.55 8,750 1,800 13.3 26.5
080.1A/14- 10,883 537 10,182 503 128 67 12.8 10,500 2,300 16.1 32.2
080.1B/17- 11,377 561 10,677 527 131 67 14.3 12,000 2,300 18.0 35.9
080.1C/17- 11,130 549 10,430 515 128 67 16.95 13,500 3,450 21.3 42.6
051C/110- 3,561 557 3,231 506 59 61 5.95 4,750 1,200 7.5 15.0
051D/110- 3,384 530 3,067 480 59 61 6.9 5,700 1,200 8.7 17.3
065.1C/110- 5,580 491 5,150 454 79 61 9.3 7,700 1,600 11.7 23.4
065.1D/110- 5,274 465 4,838 427 75 61 12.3 9,900 2,400 15.5 30.9
071.1C/110- 8,028 538 7,304 490 101 64 11.8 10,000 1,800 14.8 29.7
071.1D/110- 7,604 511 6,969 489 98 64 17.7 15,000 2,700 22.2 44.5
080.1C/110- 11,336 559 10,677 527 128 67 16.95 13,500 3,450 21.3 42.6
080.1D/110- 10,883 538 10,182 503 124 67 21.45 18,000 3,450 27.0 53.9
051C/112- 3,637 568 3,308 517 59 61 5.95 4,750 1,200 7.5 15.0
051D/112- 3,484 545 3,167 496 59 61 6.9 5,700 1,200 8.7 17.3
065.1C/112- 5,727 504 5,274 464 79 61 9.3 7,700 1,600 11.7 23.4
065.1D/112- 5,438 480 5,003 441 79 61 12.3 9,900 2,400 15.5 30.9
071.1D/112- 7,846 526 7,181 481 101 64 17.7 15,000 2,700 22.2 44.5
080.1C/112- 11,577 571 10,883 537 128 67 16.95 13,500 3,450 21.3 42.6
080.1D/112- 11,089 547 10,430 515 128 67 21.45 18,000 3,450 27.0 53.9
* Units with heater amp draws greater than 48 amps will be supplied with multiple circuits- as required by the NEC
8/14/2019 Guntner MAN
10/28keep(s) your quality. www.guntnerus.com 08.07
Performance Data: 2 Fan Models
MODEL
NO.
MAN
CAPACITIES COIL
Wet Frosted
Surface Area Tube Volume Fin Spacing
Btu/hr
/F TD
Btu/hr
/F TD ft2 ft3 fpi
041A/24- 2,798 2,248 621 0.34
6.3
041B/24- 3,743 2,470 776 0.41
046A/24- 4,721 3,633 993 0.52
046B/24- 6,049 4,700 1,241 0.67
051B/24- 7,612 5,757 1,552 0.82
065.1A/24- 10,173 7,957 2,234 1.23
065.1B/24- 13,197 9,828 2,793 1.53
071.1A/24- 13,668 10,734 2,927 1.57071.1B/24- 17,419 13,619 3,659 1.87
080.1A/24- 19,182 14,800 3,971 2.09
041A/24- 2,798 2,248 621 0.34
3.6
041B/24- 3,743 2,470 776 0.41
046A/24- 4,721 3,633 993 0.52
046B/24- 6,049 4,700 1,241 0.67
051B/24- 7,612 5,757 1,552 0.82
065.1A/24- 10,173 7,957 2,234 1.23
065.1B/24- 13,197 9,828 2,793 1.53
071.1A/24- 13,668 10,734 2,927 1.57
071.1B/24- 17,419 13,619 3,659 1.87
080.1A/24- 19,182 14,800 3,971 2.09
080.1B/27- 16,241 13,265 2,923 2.58
080.1C/27- 19,912 16,245 3,507 3.10
051C/210- 5,168 4,207 789 0.97
2.5
051D/210- 7,213 5,612 1,053 1.31
065.1C/210- 8,830 7,102 1,421 1.79
065.1D/210- 12,094 9,698 1,894 2.35
071.1C/210- 11,735 9,205 1,861 2.31
071.1D/210- 16,430 13,598 2,482 2.99
080.1C/210- 16,089 13,583 2,526 3.10
080.1D/210- 22,124 18,657 3,367 4.11
051C/212- 4,596 3,681 670 0.97
051D/212- 6,330 4,936 893 1.31
065.1C/212- 7,720 6,451 1,206 1.79
065.1D/212- 10,601 8,853 1,609 2.35 2.1
071.1D/212- 14,388 12,165 2,107 2.99
080.1C/212- 13,987 11,895 2,145 3.10
080.1D/212- 19,238 16,363 2,859 4.11
8/14/2019 Guntner MAN
11/28www.guntnerus.com keep(s) your quality.08.07
MODEL
NO.
MAN
AIR FLOW ELECTRIC DEFROST
AirThrow
SoundPressure
LevelTotal Coil Tray Amp Draws*
@ 3/460/60 @ 3/230/60 @3/460 @3/230
cfm fpm cfm fpm ft db (A) kW W W A A
041A/24- 3,320 519 3,249 506 39 54 4.6 3,300 1,300 5.8 11.6
041B/24- 3,119 488 3,049 475 39 54 4.6 3,300 1,300 5.8 11.6
046A/24- 5,168 506 4,779 465 52 61 6.1 4,500 1,600 7.7 15.3
046B/24- 4,944 484 4,556 444 52 61 7.6 6,000 1,600 9.6 19.1
051B/24- 6,533 512 5,850 456 65 63 9.3 7,200 2,100 11.7 23.4
065.1A/24- 10,583 461 9,676 419 85 63 15.8 13,200 2,600 19.9 39.7
065.1B/24- 10,088 440 9,229 400 85 63 15.8 13,200 2,600 19.9 39.7
071.1A/24- 15,268 507 13,938 460 108 67 20.5 17,500 3,000 25.8 51.5
071.1B/24- 14,667 488 13,337 441 108 67 20.5 17,500 3,000 25.8 51.5
080.1A/24- 21,766 532 20,365 495 141 69 25 21,000 4,000 31.4 62.8
041B/27- 3,555 556 3,496 544 39 54 4.6 3,300 1,300 5.8 11.6
041C/27- 3,437 538 3,378 526 39 54 5.7 4,400 1,300 7.2 14.3
046B/27- 5,415 529 5,050 491 52 61 7.6 6,000 1,600 9.6 19.1
046C/27- 5,285 517 4,921 479 52 61 9.1 7,500 1,600 11.4 22.9
051C/27- 6,969 545 6,310 491 65 63 11.1 9,000 2,100 13.9 27.9
065.1A/27- 11,536 501 10,583 457 88 63 15.8 13,200 2,600 19.9 39.7
065.1B/27- 11,207 487 10,300 445 85 63 15.8 13,200 2,600 19.9 39.7
065.1C/27- 10,877 473 10,006 433 85 63 18 15,400 2,600 22.6 45.2
071.1B/27- 16,056 532 14,609 482 108 67 20.5 17,500 3,000 25.8 51.5
071.1C/27- 15,692 521 14,302 472 108 67 23 20,000 3,000 28.9 57.8
080.1B/27- 22,755 556 21,354 519 141 69 28 24,000 4,000 35.2 70.4
080.1C/27- 22,260 544 20,859 507 141 69 33 27,000 6,000 41.5 82.9
051C/210- 7,122 557 6,463 503 65 63 11.1 9,000 2,100 13.9 27.9
051D/210- 6,769 530 6,133 478 65 63 13.4 10,800 2,600 16.8 33.7
065.1C/210- 11,159 486 10,300 445 85 63 18 15,400 2,600 22.6 45.2
065.1D/210- 10,547 460 9,676 419 85 63 23.7 19,800 3,900 29.8 59.6
071.1C/210- 16,056 532 14,609 482 108 67 23 20,000 3,000 28.9 57.8
071.1D/210- 15,209 505 13,938 461 108 66 34.5 30,000 4,500 43.4 86.7
080.1C/210- 22,672 554 21,354 519 141 69 33 27,000 6,000 41.5 82.9
080.1D/210- 21,766 533 20,365 496 137 69 42 36,000 6,000 52.8 105.6
051C/212- 7,275 568 6,616 514 65 63 11.1 9,000 2,100 13.9 27.9
051D/212- 6,969 545 6,333 493 65 63 13.4 10,800 2,600 16.8 33.7
065.1C/212- 11,454 498 10,547 456 85 63 18 15,400 2,600 22.6 45.2
065.1D/212- 10,877 473 10,006 433 85 63 23.7 19,800 3,900 29.8 59.6
071.1D/212- 15,692 521 14,361 474 108 66 34.5 30,000 4,500 43.4 86.7
080.1C/212- 23,155 565 21,766 529 144 69 33 27,000 6,000 41.5 82.9
080.1D/212- 22,178 442 20,859 507 141 69 42 36,000 6,000 52.8 105.6
* Units with heater amp draws greater than 48 amps will be supplied with multiple circuits- as required by the NEC
8/14/2019 Guntner MAN
12/28keep(s) your quality. www.guntnerus.com0 08.07
Performance Data: 3 Fan Models
MODEL
NO.
MAN
CAPACITIES COIL
Wet Frosted
Surface Area Tube Volume Fin Spacing
Btu/hr
/F TD
Btu/hr
/F TD ft2 ft3 fpi
041A/34- 4,571 2,988 931 0.49
6.3
041B/34- 5,451 3,759 1,163 0.60
046A/34- 7,169 5,479 1,489 0.82
046B/34- 9,091 6,946 1,862 0.97
051B/34- 11,757 7,272 2,327 1.23
065.1A/34- 15,386 11,275 3,365 1.75
065.1B/34- 20,348 14,227 4,206 2.13
071.1A/34- 21,304 15,961 4,406 2.28071.1B/34- 25,782 15,542 5,508 2.72
080.1A/34- 30,785 20,024 5,976 3.25
041B/37- 4,225 2,773 686 0.63
3.6
041C/37- 5,036 3,933 822 0.75
046B/37- 5,954 4,683 1,097 0.97
046C/37- 7,467 5,722 1,315 1.16
051C/37- 9,245 7,671 1,644 1.46
065.1A/37- 10,393 7,979 1,981 1.75
065.1B/37- 13,058 10,750 2,476 2.13
065.1C/37- 17,789 13,667 2,972 2.65
071.1B/37- 17,099 13,999 3,243 2.72
071.1C/37- 20,951 17,139 3,891 3.40
080.1B/37- 25,193 20,575 4,398 3.84
080.1C/37- 29,956 24,406 5,278 4.67
051C/310- 7,809 6,311 1,184 1.46
2.5
051D/310- 10,637 8,631 1,579 1.90
065.1C/310- 13,294 11,088 2,139 2.61
065.1D/310- 18,196 15,133 2,853 3.43
071.1C/310- 17,010 14,370 2,801 3.43
071.1D/310- 23,291 19,640 3,735 3.84
080.1C/310- 24,948 21,026 3,800 4.70
080.1D/310- 34,320 28,908 5,067 6.12
051C/312- 6,821 5,521 1,005 1.42
051D/312- 9,493 7,593 1,341 1.90
065.1C/312- 12,557 10,423 1,818 2.61
065.1D/312- 17,274 14,320 2,422 3.43 2.1
071.1D/312- 20,407 17,317 3,173 4.55
080.1C/312- 22,229 18,398 3,227 4.70
080.1D/312- 30,601 25,324 4,303 6.12
8/14/2019 Guntner MAN
13/28www.guntnerus.com keep(s) your quality.08.07
* Units with heater amp draws greater than 48 amps will be supplied with multiple circuits- as required by the NEC
MODEL
NO.
MAN
AIR FLOW ELECTRIC DEFROST
AirThrow
SoundPressure
LevelTotal Coil Tray Amp Draws*
@ 3/460/60 @ 3/230/60 @3/460 @3/230
cfm fpm cfm fpm ft db (A) kW W W A A
041A/34- 4,979 519 4,873 508 43 55 7 5,100 1,900 8.8 17.6
041B/34- 4,679 488 4,573 478 39 55 7 5,100 1,900 8.8 17.6
046A/34- 7,752 505 7,169 468 56 62 9 6,600 2,400 11.3 22.6
046B/34- 7,416 481 6,833 444 56 62 11.2 8,800 2,400 14.1 28.1
051B/34- 9,800 508 8,776 456 69 64 13.9 10,800 3,100 17.5 34.9
065.1A/34- 15,874 456 14,514 417 88 65 23 19,200 3,800 28.9 57.8
065.1B/34- 15,132 435 13,843 398 88 65 23 19,200 3,800 28.9 57.8
071.1A/34- 22,902 502 20,906 459 111 67 30.8 26,600 4,200 38.7 77.4
071.1B/34- 22,001 482 20,006 439 111 67 30.8 26,600 4,200 38.7 77.4
080.1A/34- 32,649 527 30,547 494 147 70 37.3 31,500 5,800 46.9 93.7
041B/37- 5,333 555 5,244 544 43 55 7 5,100 1,900 8.8 17.6
041C/37- 5,156 538 5,068 529 43 55 8.7 6,800 1,900 10.9 21.9
046B/37- 8,122 529 7,575 494 56 62 11.2 8,800 2,400 14.1 28.1
046C/37- 7,928 517 7,381 482 56 62 13.4 11,000 2,400 16.8 33.7
051C/37- 10,453 545 9,464 494 69 64 16.6 13,500 3,100 20.9 41.7
065.1A/37- 17,304 498 15,874 458 92 65 23 19,200 3,800 28.9 57.8
065.1B/37- 16,810 485 15,450 446 88 65 23 19,200 3,800 28.9 57.8
065.1C/37- 16,315 469 15,009 434 88 65 26.2 22,400 3,800 32.9 65.8
071.1B/37- 24,085 528 21,913 483 111 67 30.8 26,600 4,200 38.7 77.4
071.1C/37- 23,537 516 21,454 483 111 67 34.6 30,400 4,200 43.5 87.0
080.1B/37- 34,132 554 32,031 520 147 70 41.8 36,000 5,800 52.5 105.1
080.1C/37- 33,390 542 31,289 509 147 70 49.2 40,500 8,700 61.8 123.6
051C/310- 10,683 556 9,694 506 69 64 16.6 13,500 3,100 20.9 41.7
051D/310- 10,153 530 9,200 481 69 64 20 16,200 3,800 25.1 50.3
065.1C/310- 16,739 483 15,450 446 88 65 26.2 22,400 3,800 32.9 65.8
065.1D/310- 15,821 457 14,514 420 88 64 34.5 28,800 5,700 43.4 86.7
071.1C/310- 24,085 530 21,913 483 111 67 34.6 30,400 4,200 43.5 87.0
071.1D/310- 22,813 503 20,906 462 111 67 51.9 45,600 6,300 65.2 130.4
080.1C/310- 34,008 552 32,031 520 147 70 49.2 40,500 8,700 61.8 123.6
080.1D/310- 32,649 531 30,547 497 144 70 62.7 54,000 8,700 78.8 157.6
051C/312- 10,912 568 9,923 517 69 64 16.6 13,500 3,100 20.9 41.7
051D/312- 10,453 545 9,500 496 69 64 20 16,200 3,800 25.1 50.3
065.1C/312- 17,181 495 15,821 457 92 65 26.2 22,400 3,800 32.9 65.8
065.1D/312- 16,315 471 15,009 434 88 64 34.5 28,800 5,700 43.4 86.7
071.1D/312- 23,537 519 21,542 476 111 67 51.9 45,600 6,300 65.2 130.4
080.1C/312- 34,732 563 32,649 530 147 70 49.2 40,500 8,700 61.8 123.6
080.1D/312- 33,267 540 31,289 509 147 70 62.7 54,000 8,700 78.8 157.6
8/14/2019 Guntner MAN
14/28keep(s) your quality. www.guntnerus.com2 08.07
Performance Data: 4 Fan Models
MODEL
NO.
MAN
CAPACITIES COIL
Wet Frosted
Surface Area Tube Volume Fin Spacing
Btu/hr
/F TD
Btu/hr
/F TD ft2 ft3 fpi
065.1A/44- 21,058 16,025 4,496 2.46
6.3
065.1B/44- 26,080 20,276 5,620 2.90
071.1A/44- 28,053 20,745 5,885 3.04
071.1B/44- 35,579 26,296 7,356 3.91
080.1A/44- 38,522 29,756 7,980 4.20
065.1A/47- 13,670 10,987 2,647 2.46
3.6
065.1B/47- 17,776 14,076 3,309 2.90
065.1C/47- 20,864 16,699 3,971 3.48
071.1B/47- 23,276 18,902 4,331 3.91
071.1C/47- 29,167 23,559 5,198 4.49
080.1B/47- 33,203 26,048 5,874 5.07
080.1C/47- 40,001 31,880 7,048 6.23
065.1C/410- 17,769 14,038 2,859 3.48
2.5
065.1D/410- 23,929 19,859 3,812 4.63
071.1C/410- 24,072 19,329 3,742 4.49
071.1D/410- 33,017 26,173 4,989 5.94
080.1C/410- 32,943 27,293 5,074 6.23
080.1D/410- 45,310 37,486 6,766 8.11
065.1C/412-15,989 12,548 2,428 3.48
065.1D/412- 21,537 17,463 3,237 4.63
071.1D/412- 28,909 23,786 4,237 5.94 2.1
080.1C/412- 28,650 23,875 4,310 6.23
080.1D/412- 39,437 32,844 5,746 8.11
8/14/2019 Guntner MAN
15/28www.guntnerus.com keep(s) your quality.08.07
MODEL
NO.
MAN
AIR FLOW
Air ThrowSound
PressureLevel
@ 3/460/60 @ 3/230/60
cfm m/s fpm cfm m/s fpm ft db (A)
065.1A/44- 21,165 2.30 452 19,353 2.10 414 105 66
065.1B/44- 20,177 2.19 431 18,458 2.00 394 105 66
071.1A/44- 30,536 2.53 499 27,875 2.31 455 124 68
071.1B/44- 29,335 2.43 479 26,674 2.21 436 124 68
080.1A/44- 43,531 2.66 524 40,730 2.49 490 154 71
065.1A/47- 23,072 2.50 493 21,165 2.30 452 105 67
065.1B/47- 22,413 2.43 479 20,600 2.24 440 105 66
065.1C/47- 21,754 2.36 465 20,012 2.17 428 105 66
071.1B/47- 32,113 2.66 524 29,217 2.42 477 124 68
071.1C/47- 31,383 2.60 512 28,605 2.37 467 124 68
080.1B/47- 45,509 2.78 548 42,707 2.61 514 154 71
080.1C/47- 44,520 2.72 536 41,719 2.55 502 154 71
065.1C/410- 22,319 2.42 477 20,600 2.24 440 105 66
065.1D/410- 21,095 2.29 451 19,353 2.10 414 105 65
071.1C/410- 32,113 2.66 524 29,217 2.42 477 124 66
071.1D/410- 30,418 2.52 497 27,875 2.31 455 124 68
080.1C/410- 45,344 2.77 546 42,707 2.61 514 154 71
080.1D/410- 43,531 2.66 524 40,730 2.49 490 154 71
065.1C/412- 22,908 2.49 490 21,095 2.29 451 105 66
065.1D/412- 21,754 2.36 465 20,012 2.17 428 105 65
071.1D/412- 31,383 2.60 512 28,723 2.38 469 124 68
080.1C/412- 46,309 2.83 558 43,531 2.66 524 154 71
080.1D/412- 44,355 2.71 534 41,719 2.55 502 154 71
* No Electric defrost for 4 fan models
8/14/2019 Guntner MAN
16/28keep(s) your quality. www.guntnerus.com4 08.07
Performance Data: 5 Fan Models
MODEL
NO.
MAN
CAPACITIES COIL
Wet Frosted
Surface Area Tube Volume Fin
Spacing
Btu/hr
/F TD
Btu/hr
/F TD ft2 ft3 fpi
065.1A/54- 26,688 19,524 5,627 3.07
6.3
065.1B/54- 34,008 24,558 7,034 3.61
071.1A/54- 34,393 27,030 7,364 3.79
071.1B/54- 43,858 34,291 9,205 4.88
080.1A/54- 48,433 30,010 9,985 5.24
065.1A/57- 17,291 13,964 3,313 3.07
3.6
065.1B/57- 21,818 17,979 4,141 3.61
065.1C/57- 26,698 21,955 4,970 4.34
071.1B/57- 28,846 23,101 5,420 4.88
071.1C/57- 36,886 28,253 6,504 5.60
080.1B/57- 40,858 32,771 7,349 6.32
080.1C/57- 50,114 40,128 8,819 7.77
065.1C/510- 21,919 17,973 3,578 4.34
2.5
065.1D/510- 30,281 24,552 4,771 5.78
071.1C/510- 29,892 24,230 4,683 5.60
071.1D/510- 41,397 32,969 6,243 7.41
080.1C/510- 41,577 32,936 6,349 7.77
080.1D/510- 57,243 45,224 8,465 10.12
065.1C/512- 19,158 15,721 3,039 4.34
065.1D/512- 27,028 21,577 4,052 5.78
071.1D/512- 36,288 27,742 5,302 7.41 2.1
080.1C/512- 36,154 29,944 5,392 7.77
080.1D/512- 49,744 41,192 7,189 10.12
8/14/2019 Guntner MAN
17/28www.guntnerus.com keep(s) your quality.08.07
MODEL
NO.
MAN
AIR FLOW
Air ThrowSound
PressureLevel
@ 3/460/60 @ 3/230/60
cfm m/s fpm cfm m/s fpm ft db (A)
065.1A/54- 26,457 2.30 452 24,191 2.10 413 108 66
065.1B/54- 25,221 2.19 431 23,072 2.00 394 108 67
071.1A/54- 38,169 2.53 498 34,844 2.31 455 128 68
071.1B/54- 36,669 2.43 478 33,343 2.21 435 128 69
080.1A/54- 54,414 2.66 524 50,912 2.49 490 157 72
065.1A/57- 28,840 2.50 492 26,457 2.30 452 108 68
065.1B/57- 28,016 2.43 478 25,750 2.23 440 108 67
065.1C/57- 27,192 2.36 464 25,015 2.17 427 108 67
071.1B/57- 40,141 2.66 524 36,521 2.42 477 128 68
071.1C/57- 39,229 2.60 512 35,756 2.37 467 128 69
080.1B/57- 56,886 2.78 547 53,384 2.61 514 157 72
080.1C/57- 55,650 2.72 536 52,148 2.55 502 157 72
065.1C/510- 27,899 2.42 476 25,750 2.23 440 108 67
065.1D/510- 26,368 2.29 450 24,191 2.10 413 108 66
071.1C/510- 40,141 2.66 524 36,521 2.42 477 128 66
071.1D/510- 38,022 2.52 496 34,844 2.31 455 128 69
080.1C/510- 56,680 2.77 545 53,384 2.61 514 157 72
080.1D/510- 54,414 2.66 524 50,912 2.49 490 157 72
065.1C/512- 28,634 2.48 489 26,368 2.29 450 108 67
065.1D/512- 27,192 2.36 464 25,015 2.17 427 108 66
071.1D/512- 39,229 2.60 512 35,903 2.38 468 128 69
080.1C/512- 57,887 2.83 557 54,414 2.66 524 157 72
080.1D/512- 55,444 2.71 534 52,148 2.55 502 157 72
* No Electric defrost for 4 fan models
8/14/2019 Guntner MAN
18/28keep(s) your quality. www.guntnerus.com6 08.07
Dimensions: 1 Fan Models
MODEL
NO.
MAN
UNIT DIMENSIONS CONNECTIONS
* with water defrost option add 4 inches to H and M Refrigerant Hot
Gas Drain
DryWeight
L
inch
B
inch
H*
inch
E
inch
F
inch
M *
inch
S
inch
A
inch
in
NPS
out
NPS
in
NPS NPT lb
041A/14- 39 1/5 26 1/6 22 1/4 24 4/5 21 2/3 33 1/2 31 1/9 9 5/6 1/2 1/2 1/2 3/4 121
041B/14- 39 1/5 26 1/6 22 1/4 24 4/5 21 2/3 33 1/2 31 1/9 9 5/6 1/2 1/2 1/2 3/4 129
046A/14- 47 27 26 1/6 32 2/3 21 2/3 37 4/5 31 1/9 17 5/7 1/2 1/2 1/2 3/4 158
046B/14- 47 27 26 1/6 32 2/3 21 2/3 37 4/5 31 1/9 17 5/7 1/2 1/2 1/2 3/4 175
051B/14- 55 27 1/6 26 1/6 40 5/9 21 2/3 37 4/5 31 1/9 17 5/7 1/2 1 1/2 3/4 201
065.1A/14- 78 32 5/7 39 3/4 47 5/6 21 6/7 48 6/7 31 1/9 27 5/9 1/2 1 1/2 1 1/4 340
065.1B/14- 78 32 5/7 39 3/4 47 5/6 21 6/7 48 6/7 31 1/9 27 5/9 1/2 1 1/2 1/2 1 1/4 371
071.1A/14- 86 1/2 32 5/7 43 5/7 56 2/7 21 6/7 50 1/4 31 1/9 27 5/9 1/2 1 1/2 1/2 1 1/4 418
071.1B/14- 86 1/2 32 5/7 43 5/7 56 2/7 21 6/7 50 1/4 31 1/9 27 5/9 1/2 1 1/2 1/2 1 1/4 458
080.1A/14- 93 3/4 38 51 63 4/7 25 4/5 60 2/3 35 27 5/9 1/2 2 1/2 1 1/4 563
041B/17- 39 1/5 26 1/6 22 1/4 24 4/5 21 2/3 33 1/2 31 1/9 9 5/6 1/2 1/2 1/2 3/4 116
041C/17- 39 1/5 26 1/6 22 1/4 24 4/5 21 2/3 33 1/2 31 1/9 9 5/6 1/2 1/2 1/2 3/4 125
046B/17- 47 27 26 1/6 32 2/3 21 2/3 37 4/5 31 1/9 17 5/7 1/2 1/2 1/2 3/4 155
046C/17- 47 27 26 1/6 32 2/3 21 2/3 37 4/5 31 1/9 17 5/7 1/2 1/2 1/2 3/4 166
051C/17- 55 27 1/6 26 1/6 40 5/9 21 2/3 37 4/5 31 1/9 17 5/7 1/2 1 1/2 3/4 190
065.1A/17- 78 32 5/7 39 3/4 47 5/6 21 6/7 48 6/7 31 1/9 27 5/9 1/2 1 1/2 1 1/4 306
065.1B/17- 78 32 5/7 39 3/4 47 5/6 21 6/7 48 6/7 31 1/9 27 5/9 1/2 1 1/2 1 1/4 333
065.1C/17- 78 32 5/7 39 3/4 47 5/6 21 6/7 48 6/7 31 1/9 27 5/9 1/2 1 1/2 1 1/4 357
071.1B/17- 86 1/2 32 5/7 43 5/7 56 2/7 21 6/7 50 1/4 31 1/9 27 5/9 1/2 1 1/2 1/2 1 1/4 408
071.1C/17- 86 1/2 32 5/7 43 5/7 56 2/7 21 6/7 50 1/4 31 1/9 27 5/9 1/2 1 1/2 1/2 1 1/4 438
080.1B/17- 93 3/4 38 51 63 4/7 25 4/5 60 2/3 35 27 5/9 1/2 1 1/2 1/2 1 1/4 545
080.1C/17- 93 3/4 41 8/9 51 63 4/7 29 5/7 60 2/3 39 27 5/9 1/2 2 1/2 1 1/4 612
051C/110- 55 27 1/6 26 1/6 40 5/9 21 2/3 37 4/5 31 1/9 17 5/7 1/2 1 1/2 3/4 190
051D/110- 55 31 1/9 26 1/6 40 5/9 25 3/5 37 4/5 35 17 5/7 1/2 1 1/2 3/4 229
065.1C/110- 78 32 5/7 39 3/4 47 5/6 21 6/7 48 6/7 31 1/9 27 5/9 1/2 1 1/2 1 1/4 357
065.1D/110- 78 40 3/5 39 3/4 47 5/6 29 5/7 48 6/7 39 27 5/9 1/2 1 1/2 1/2 1 1/4 436
071.1C/110- 86 1/2 32 5/7 43 5/7 56 2/7 21 6/7 50 1/4 31 1/9 27 5/9 1/2 1 1/2 1/2 1 1/4 439
071.1D/110- 86 1/2 40 3/5 43 5/7 56 2/7 29 5/7 50 1/4 39 27 5/9 1/2 1 1/2 1/2 1 1/4 543
080.1C/110- 93 3/4 41 8/9 51 63 4/7 29 5/7 60 2/3 39 27 5/9 1/2 1 1/2 1/2 1 1/4 612
080.1D/110- 93 3/4 41 8/9 51 63 4/7 29 5/7 60 2/3 39 27 5/9 1/2 2 1/2 1 1/4 695
051C/112- 55 27 1/6 26 1/6 40 5/9 21 2/3 37 4/5 31 1/9 17 5/7 1/2 1 1/2 3/4 184
051D/112- 55 31 1/9 26 1/6 40 5/9 25 3/5 37 4/5 35 17 5/7 1/2 1 1/2 3/4 217
065.1C/112- 78 32 5/7 39 3/4 47 5/6 21 6/7 48 6/7 31 1/9 27 5/9 1/2 1 1/2 1 1/4 341
065.1D/112- 78 40 3/5 39 3/4 47 5/6 29 5/7 48 6/7 39 27 5/9 1/2 1 1/2 1 1/4 420
071.1D/112- 86 1/2 40 3/5 43 5/7 56 2/7 29 5/7 50 1/4 39 27 5/9 1/2 1 1/2 1/2 1 1/4 523
080.1C/112- 93 3/4 41 8/9 51 63 4/7 29 5/7 60 2/3 39 27 5/9 1/2 1 1/2 1/2 1 1/4 592
080.1D/112- 93 3/4 41 8/9 51 63 4/7 29 5/7 60 2/3 39 27 5/9 1/2 2 1/2 1 1/4 668
Dimension A refers to distance between cooler and wall
8/14/2019 Guntner MAN
19/28www.guntnerus.com keep(s) your quality.08.07
DRAWING FOR MODELS 065, 071, 080
DRAWING FOR MODELS 041, 046, 051
8/14/2019 Guntner MAN
20/28keep(s) your quality. www.guntnerus.com8 08.07
Dimensions: 2 Fan Models
MODEL
NO.
MAN
UNIT DIMENSIONS CONNECTIONS
* with water defrost option add 4 inches to H and M Refrigerant Hot
Gas Drain
DryWeight
L
inch
B
inch
H*
inch
E
inch
F
inch
M *
inch
S
inch
A
inch
in
NPS
out
NPS
in
NPS NPT lb
041A/24- 62 5/6 26 1/6 22 1/4 48 3/7 21 2/3 33 1/2 31 1/9 9 5/6 1/2 1 1/2 3/4 193
041B/24- 62 5/6 26 1/6 22 1/4 48 3/7 21 2/3 33 1/2 31 1/9 9 5/6 1/2 1 1/2 3/4 212
046A/24- 78 4/7 27 26 1/6 64 1/6 21 2/3 37 4/5 31 1/9 17 5/7 1/2 1 1/2 1 1/4 269
046B/24- 78 4/7 27 26 1/6 64 1/6 21 2/3 37 4/5 31 1/9 17 5/7 1/2 1 1/2 1 1/4 300
051B/24- 97 1/2 27 1/6 26 1/6 80 21 2/3 37 4/5 31 1/9 17 5/7 1/2 1 1/2 1/2 1 1/4 355
065.1A/24- 125 5/6 32 5/7 39 3/4 47 5/6 21 6/7 48 6/7 31 1/9 27 5/9 1/2 2 3/4 1 1/4 595
065.1B/24- 125 5/6 32 5/7 39 3/4 47 5/6 21 6/7 48 6/7 31 1/9 27 5/9 1/2 2 3/4 1 1/4 657
071.1A/24- 142 3/4 32 5/7 43 5/7 56 2/7 21 6/7 50 1/4 31 1/9 27 5/9 1/2 2 1 1 1/4 749
071.1B/24- 142 3/4 32 5/7 43 5/7 56 2/7 21 6/7 50 1/4 31 1/9 27 5/9 1/2 2 1 1 1/4 828
080.1A/24- 157 1/3 38 51 63 4/7 25 4/5 60 2/3 35 27 5/9 1/2 2 1 1 1/4 1,005
041B/27- 62 5/6 26 1/6 22 1/4 48 3/7 21 2/3 33 1/2 31 1/9 9 5/6 1/2 1 1/2 3/4 187
041C/27- 62 5/6 26 1/6 22 1/4 48 3/7 21 2/3 33 1/2 31 1/9 9 5/6 1/2 1 1/2 3/4 203
046B/27- 78 4/7 27 26 1/6 64 1/6 21 2/3 37 4/5 31 1/9 17 5/7 1/2 1 1/2 1 1/4 259
046C/27- 78 4/7 27 26 1/6 64 1/6 21 2/3 37 4/5 31 1/9 17 5/7 1/2 1 1/2 1 1/4 282
051C/27- 97 1/2 27 1/6 26 1/6 80 21 2/3 37 4/5 31 1/9 17 5/7 1/2 1 1/2 1/2 1 1/4 333
065.1A/27- 125 5/6 32 5/7 39 3/4 47 5/6 21 6/7 48 6/7 31 1/9 27 5/9 1/2 1 1/2 3/4 1 1/4 517
065.1B/27- 125 5/6 32 5/7 39 3/4 47 5/6 21 6/7 48 6/7 31 1/9 27 5/9 1/2 2 3/4 1 1/4 568
065.1C/27- 125 5/6 32 5/7 39 3/4 47 5/6 21 6/7 48 6/7 31 1/9 27 5/9 1/2 2 3/4 1 1/4 620
071.1B/27- 142 3/4 32 5/7 43 5/7 56 2/7 21 6/7 50 1/4 31 1/9 27 5/9 1/2 2 1 1 1/4 713
071.1C/27- 142 3/4 32 5/7 43 5/7 56 2/7 21 6/7 50 1/4 31 1/9 27 5/9 1/2 2 1 1 1/4 780
080.1B/27- 157 1/3 38 51 63 4/7 25 4/5 60 2/3 35 27 5/9 1/2 2 1 1 1/4 962
080.1C/27- 157 1/3 41 8/9 51 63 4/7 29 5/7 60 2/3 39 27 5/9 3/4 2 1 1 1/4 1,078
051C/210- 97 1/2 27 1/6 26 1/6 80 21 2/3 37 4/5 31 1/9 17 5/7 1/2 1 1/2 1 1/4 333
051D/210- 97 1/2 31 1/9 26 1/6 80 25 3/5 37 4/5 35 17 5/7 1/2 1 1/2 1/2 1 1/4 405
065.1C/210- 125 5/6 32 5/7 39 3/4 47 5/6 21 6/7 48 6/7 31 1/9 27 5/9 1/2 2 3/4 1 1/4 616
065.1D/210- 125 5/6 40 3/5 39 3/4 47 5/6 29 5/7 48 6/7 39 27 5/9 1/2 2 3/4 1 1/4 759
071.1C/210- 142 3/4 32 5/7 43 5/7 56 2/7 21 6/7 50 1/4 31 1/9 27 5/9 1/2 2 1 1 1/4 775
071.1D/210- 142 3/4 40 3/5 43 5/7 56 2/7 29 5/7 50 1/4 39 27 5/9 1/2 2 1 1 1/4 953
080.1C/210- 157 1/3 41 8/9 51 63 4/7 29 5/7 60 2/3 39 27 5/9 1/2 2 1 1 1/4 1,073
080.1D/210- 157 1/3 41 8/9 51 63 4/7 29 5/7 60 2/3 39 27 5/9 3/4 2 1 1 1/4 1,253
051C/212- 97 1/2 27 1/6 26 1/6 80 21 2/3 37 4/5 31 1/9 17 5/7 1/2 1 1/2 1 1/4 322
051D/212- 97 1/2 31 1/9 26 1/6 80 25 3/5 37 4/5 35 17 5/7 1/2 1 1/2 1/2 1 1/4 390
065.1C/212- 125 5/6 32 5/7 39 3/4 47 5/6 21 6/7 48 6/7 31 1/9 27 5/9 1/2 1 1/2 3/4 1 1/4 594
065.1D/212- 125 5/6 40 3/5 39 3/4 47 5/6 29 5/7 48 6/7 39 27 5/9 1/2 2 3/4 1 1/4 730
071.1D/212- 142 3/4 40 3/5 43 5/7 56 2/7 29 5/7 50 1/4 39 27 5/9 1/2 2 1 1 1/4 913
080.1C/212- 157 1/3 41 8/9 51 63 4/7 29 5/7 60 2/3 39 27 5/9 1/2 2 1 1 1/4 1,034
080.1D/212- 157 1/3 41 8/9 51 63 4/7 29 5/7 60 2/3 39 27 5/9 3/4 2 1 1 1/4 1,198
Dimension A refers to distance between cooler and wall
8/14/2019 Guntner MAN
21/28www.guntnerus.com keep(s) your quality.08.07
DRAWING FOR MODELS 065, 071, 080
DRAWING FOR MODELS 041, 046, 051
8/14/2019 Guntner MAN
22/28keep(s) your quality. www.guntnerus.com0 08.07
Dimensions: 3 Fan Models
MODEL
NO.
MAN
UNIT DIMENSIONS CONNECTIONS
* with water defrost option add 4 inches to H and M Refrigerant Hot
Gas Drain
DryWeight
L
inch
B
inch
H*
inch
E
inch
F
inch
M *
inch
S
inch
A
inch
in
NPS
out
NPS
in
NPS NPT lb
041A/34- 89 3/5 26 1/6 22 1/4 24 21 2/3 33 1/2 31 1/9 9 5/6 1/2 1 1/2 1 1/4 274
041B/34- 89 3/5 26 1/6 22 1/4 24 21 2/3 33 2/3 31 1/9 9 5/6 1/2 1 1/2 1 1/4 299
046A/34- 113 2/9 27 26 1/6 31 8/9 21 2/3 37 4/5 31 1/9 17 5/7 1/2 1 1/2 1/2 1 1/4 386
046B/34- 113 2/9 27 26 1/6 31 8/9 21 2/3 37 4/5 31 1/9 17 5/7 1/2 1 1/2 1/2 1 1/4 429
051B/34- 143 1/2 27 1/6 26 1/6 39 3/4 21 2/3 37 4/5 31 1/9 17 5/7 1/2 2 3/4 1 1/4 519
065.1A/34- 173 2/3 32 5/7 39 3/4 47 5/6 21 6/7 48 6/7 31 1/9 27 5/9 1/2 2 1 1 1/4 845
065.1B/34- 173 2/3 32 5/7 39 3/4 47 5/6 21 6/7 48 6/7 31 1/9 27 5/9 1/2 2 1 1 1/4 937
071.1A/34- 199 32 5/7 43 5/7 56 2/7 21 6/7 50 1/4 31 1/9 27 5/9 3/4 2 1 1 1/4 1,073
071.1B/34- 199 32 5/7 43 5/7 56 2/7 21 6/7 50 1/4 31 1/9 27 5/9 3/4 2 1 1 1/4 1,187
080.1A/34- 221 38 51 63 4/7 25 4/5 60 2/3 35 27 5/9 3/4 2 1 2 x 1_ 1,462
041B/37- 89 3/5 26 1/6 22 1/4 24 21 2/3 33 1/2 31 1/9 9 5/6 1/2 1 1/2 1 1/4 264
041C/37- 89 3/5 26 1/6 22 1/4 24 21 2/3 33 1/2 31 1/9 9 5/6 1/2 1 1/2 1 1/4 284
046B/37- 113 2/9 27 26 1/6 31 8/9 21 2/3 37 4/5 31 1/9 17 5/7 1/2 1 1/2 1/2 1 1/4 371
046C/37- 113 2/9 27 26 1/6 31 8/9 21 2/3 37 4/5 31 1/9 17 5/7 1/2 1 1/2 1/2 1 1/4 403
051C/37- 143 1/2 27 1/6 26 1/6 39 3/4 21 2/3 37 4/5 31 1/9 17 5/7 1/2 2 3/4 1 1/4 485
065.1A/37- 173 2/3 32 5/7 39 3/4 47 5/6 21 6/7 48 6/7 31 1/9 27 5/9 1/2 2 1 1 1/4 741
065.1B/37- 173 2/3 32 5/7 39 3/4 47 5/6 21 6/7 48 6/7 31 1/9 27 5/9 1/2 2 1 1 1/4 807
065.1C/37- 173 2/3 32 5/7 39 3/4 47 5/6 21 6/7 48 6/7 31 1/9 27 5/9 1/2 2 1 1 1/4 887
071.1B/37- 199 32 5/7 43 5/7 56 2/7 21 6/7 50 1/4 31 1/9 27 5/9 1/2 2 1 1 1/4 1,017
071.1C/37- 199 32 5/7 43 5/7 56 2/7 21 6/7 50 1/4 31 1/9 27 5/9 3/4 2 1 1 1/4 1,126
080.1B/37- 221 38 51 63 4/7 25 4/5 60 2/3 35 27 5/9 3/4 2 1 2 x 1_ 1,391
080.1C/37- 221 41 8/9 51 63 4/7 29 5/7 60 2/3 39 27 5/9 3/4 2 1 2 x 1_ 1,563
051C/310- 143 1/2 27 1/6 26 1/6 39 3/4 21 2/3 37 4/5 31 1/9 17 5/7 1/2 1 1/2 3/4 1 1/4 483
051D/310- 143 1/2 31 1/9 26 1/6 39 3/4 25 3/5 37 4/5 35 17 5/7 1/2 2 3/4 1 1/4 586
065.1C/310- 173 2/3 32 5/7 39 3/4 47 5/6 21 6/7 48 6/7 31 1/9 27 5/9 1/2 2 1 1 1/4 876
065.1D/310- 173 2/3 40 3/5 39 3/4 47 5/6 29 5/7 48 6/7 39 27 5/9 1/2 2 1 1 1/4 1,083
071.1C/310- 199 32 5/7 43 5/7 56 2/7 21 6/7 50 1/4 31 1/9 27 5/9 1/2 2 1 1 1/4 1,122
071.1D/310- 199 40 3/5 43 5/7 56 2/7 29 5/7 50 1/4 39 27 5/9 3/4 2 1 1 1/4 1,322
080.1C/310- 221 41 8/9 51 63 4/7 29 5/7 60 2/3 39 27 5/9 3/4 2 1 2 x 1 1/4 1,555
080.1D/310- 221 41 8/9 51 63 4/7 29 5/7 60 2/3 39 27 5/9 3/4 2 1 2 x 1 1/4 1,810
051C/312- 143 1/2 27 1/6 26 1/6 39 3/4 21 2/3 37 4/5 31 1/9 17 5/7 1/2 1 1/2 3/4 1 1/4 466
051D/312- 143 1/2 31 1/9 26 1/6 39 3/4 25 3/5 37 4/5 35 17 5/7 1/2 2 3/4 1 1/4 561
065.1C/312- 173 2/3 32 5/7 39 3/4 47 5/6 21 6/7 48 6/7 31 1/9 27 5/9 1/2 2 1 1 1/4 843
065.1D/312- 173 2/3 40 3/5 39 3/4 47 5/6 29 5/7 48 6/7 39 27 5/9 1/2 2 1 1 1/4 1,039
071.1D/312- 199 40 3/5 43 5/7 56 2/7 29 5/7 50 1/4 39 27 5/9 3/4 2 1 1 1/4 1,324
080.1C/312- 221 41 8/9 51 63 4/7 29 5/7 60 2/3 39 27 5/9 3/4 2 1 2 x 1 1/4 1,495
080.1D/312- 221 41 8/9 51 63 4/7 29 5/7 60 2/3 39 27 5/9 3/4 2 1 2 x 1 1/4 1,731
Dimension A refers to distance between cooler and wall
8/14/2019 Guntner MAN
23/28www.guntnerus.com keep(s) your quality.08.07
DRAWING FOR MODELS 065, 071, 080
DRAWING FOR MODELS 041, 046, 051
8/14/2019 Guntner MAN
24/28keep(s) your quality. www.guntnerus.com2 08.07
Dimensions: 4 Fan Models
MODEL
NO.
MAN
UNIT DIMENSIONS CONNECTIONS
* with water defrost option add 4 inches to H and M Refrigerant Hot
Gas Drain
DryWeight
L
inch
B
inch
H*
inch
E
inch
F
inch
M *
inch
S
inch
A
inch
in
NPS
out
NPS
in
NPS NPT lb
065.1A/44- 222 5/8 32 3/4 39 3/4 47 7/8 21 7/8 48 7/8 31 1/8 27 1/2 3/4 2 1 2x1 1/4" 1,685
065.1B/44- 222 5/8 32 3/4 39 3/4 47 7/8 21 7/8 48 7/8 31 1/8 27 1/2 3/4 2 1/2 1 2x1 1/4" 1,805
071.1A/44- 256 1/2 32 3/4 43 3/4 56 1/4 21 7/8 50 1/4 31 1/8 27 1/2 3/4 2 1/2 1 1/4 2x1 1/4" 2,052
071.1B/44- 256 1/2 32 3/4 43 3/4 56 1/4 21 7/8 50 1/4 31 1/8 27 1/2 1 2 1/2 1 1/4 2x1 1/4" 2,210
080.1A/44- 285 1/2 38 51 63 5/8 25 3/4 60 5/8 35 27 1/2 1 2 1/2 1 1/4 2x1 1/4" 2,524
065.1A/47- 222 5/8 32 3/4 39 3/4 47 7/8 21 7/8 48 7/8 31 1/8 27 1/2 1/2 2 1 2x1 1/4" 1,546
065.1B/47- 222 5/8 32 3/4 39 3/4 47 7/8 21 7/8 48 7/8 31 1/8 27 1/2 3/4 2 1 2x1 1/4" 1,628
065.1C/47- 222 5/8 32 3/4 39 3/4 47 7/8 21 7/8 48 7/8 31 1/8 27 1/2 3/4 2 1 2x1 1/4" 1,718
071.1B/47- 256 1/2 32 3/4 43 3/4 56 1/4 21 7/8 50 1/4 31 1/8 27 1/2 3/4 2 1/2 1 1/4 2x1 1/4" 1,981
071.1C/47- 256 1/2 32 3/4 43 3/4 56 1/4 21 7/8 50 1/4 31 1/8 27 1/2 1 2 1/2 1 1/4 2x1 1/4" 2,096
080.1B/47- 285 1/2 38 51 63 5/8 25 3/4 60 5/8 35 27 1/2 1 3 1 1/4 2x1 1/4" 2,431
080.1C/47- 285 1/2 41 7/8 51 63 5/8 29 3/4 60 5/8 39 27 1/2 1 3 1 1/2 2x1 1/4" 2,649
065.1C/410- 222 5/8 32 3/4 39 3/4 47 7/8 21 7/8 48 7/8 31 1/8 27 1/2 3/4 2 1 2x1 1/4" 1,710
065.1D/410- 222 5/8 40 5/8 39 3/4 47 7/8 29 3/4 48 7/8 39 27 1/2 3/4 2 1/2 1 2x1 1/4" 1,968
071.1C/410- 256 1/2 32 3/4 43 3/4 56 1/4 21 7/8 50 1/4 31 1/8 27 1/2 3/4 2 1/2 1 1/4 2x1 1/4" 2,093
071.1D/410- 256 1/2 40 5/8 43 3/4 56 1/4 29 3/4 50 1/4 39 27 1/2 1 3 1 1/4 2x1 1/4" 2,420
080.1C/410- 285 1/2 41 7/8 51 63 5/8 29 3/4 60 5/8 39 27 1/2 1 3 1 1/2 2x1 1/4" 2,632
080.1D/410- 285 1/2 41 7/8 51 63 5/8 29 3/4 60 5/8 39 27 1/2 1 1/4 4 1 1/2 2x1 1/4" 2,952
065.1C/412- 222 5/8 32 3/4 39 3/4 47 7/8 21 7/8 48 7/8 31 1/8 27 1/2 1/2 2 1 2x1 1/4" 1,666
065.1D/412- 222 5/8 40 5/8 39 3/4 47 7/8 29 3/4 48 7/8 39 27 1/2 3/4 2 1/2 1 2x1 1/4" 1,908
071.1D/412- 256 1/2 40 5/8 43 3/4 56 1/4 29 3/4 50 1/4 39 27 1/2 1 3 1 1/4 2x1 1/4" 2,341
080.1C/412- 285 1/2 41 7/8 51 63 5/8 29 3/4 60 5/8 39 27 1/2 1 2 1/2 1 1/2 2x1 1/4" 2,552
080.1D/412- 285 1/2 41 7/8 51 63 5/8 29 3/4 60 5/8 39 27 1/2 1 3 1 1/2 2x1 1/4" 2,844
Dimension A refers to distance between cooler and wall
8/14/2019 Guntner MAN
25/28www.guntnerus.com keep(s) your quality.08.07
DRAWING FOR ALL MODELS
8/14/2019 Guntner MAN
26/28keep(s) your quality. www.guntnerus.com4 08.07
Dimensions: 5 Fan Models
MODEL
NO.
MAN
UNIT DIMENSIONS CONNECTIONS
* with water defrost option add 4 inches to H and M Refrigerant Hot
Gas Drain
DryWeight
L
inch
B
inch
H*
inch
E
inch
F
inch
M *
inch
S
inch
A
inch
in
NPS
out
NPS
in
NPS NPT lb
065.1A/54- 270 1/2 32 5/7 39 3/4 47 5/6 21 6/7 48 6/7 31 1/9 27 5/9 3/4 2 1 2x1 1/4" 2,063
065.1B/54- 270 1/2 32 5/7 39 3/4 47 5/6 21 6/7 48 6/7 31 1/9 27 5/9 1 2 1/2 1 2x1 1/4" 2,210
071.1A/54- 312 4/5 32 5/7 43 5/7 56 2/7 21 6/7 50 1/4 31 1/9 27 5/9 1 2 1/2 1 1/4 2x1 1/4" 2,517
071.1B/54- 312 4/5 32 5/7 43 5/7 56 2/7 21 6/7 50 1/4 31 1/9 27 5/9 1 2 1/2 1 1/4 2x1 1/4" 2,718
080.1A/54- 348 5/6 38 51 63 4/7 25 4/5 60 2/3 35 27 5/9 1 2 1/2 1 1/2 2x 3" 3,097
065.1A/57- 270 1/2 32 5/7 39 3/4 47 5/6 21 6/7 48 6/7 31 1/9 27 5/9 1/2 2 1 2x1 1/4" 1,888
065.1B/57- 270 1/2 32 5/7 39 3/4 47 5/6 21 6/7 48 6/7 31 1/9 27 5/9 3/4 2 1/2 1 2x1 1/4" 1,994
065.1C/57- 270 1/2 32 5/7 39 3/4 47 5/6 21 6/7 48 6/7 31 1/9 27 5/9 3/4 2 1/2 1 2x1 1/4" 2,102
071.1B/57- 312 4/5 32 5/7 43 5/7 56 2/7 21 6/7 50 1/4 31 1/9 27 5/9 1 2 1/2 1 1/4 2x1 1/4" 2,424
071.1C/57- 312 4/5 32 5/7 43 5/7 56 2/7 21 6/7 50 1/4 31 1/9 27 5/9 1 3 1 1/4 2x1 1/4" 2,570
080.1B/57- 348 5/6 38 51 63 4/7 25 4/5 60 2/3 35 27 5/9 1 3 1 1/2 2x 3" 2,983
080.1C/57- 348 5/6 41 8/9 51 63 4/7 29 5/7 60 2/3 39 27 5/9 1 1/4 3 1 1/2 2x 3" 3,241
065.1C/510- 270 1/2 32 5/7 39 3/4 47 5/6 21 6/7 48 6/7 31 1/9 27 5/9 3/4 2 1 2x1 1/4" 2,096
065.1D/510- 270 1/2 40 3/5 39 3/4 47 5/6 29 5/7 48 6/7 39 27 5/9 1 3 1 1/4 2x1 1/4" 2,422
071.1C/510- 312 4/5 32 5/7 43 5/7 56 2/7 21 6/7 50 1/4 31 1/9 27 5/9 1 2 1/2 1 1/4 2x1 1/4" 2,559
071.1D/510- 312 4/5 40 3/5 43 5/7 56 2/7 29 5/7 50 1/4 39 27 5/9 1 3 1 1/2 2x1 1/4" 2,978
080.1C/510- 348 5/6 41 8/9 51 63 4/7 29 5/7 60 2/3 39 27 5/9 1 3 1 1/2 2x 3" 3,230
080.1D/510- 348 5/6 41 8/9 51 63 4/7 29 5/7 60 2/3 39 27 5/9 1 1/4 4 1 1/2 2x 3" 3,618
065.1C/512- 270 1/2 32 5/7 39 3/4 47 5/6 21 6/7 48 6/7 31 1/9 27 5/9 3/4 2 1 2x1 1/4" 2,038
065.1D/512- 270 1/2 40 3/5 39 3/4 47 5/6 29 5/7 48 6/7 39 27 5/9 1 2 1/2 1 1/4 2x1 1/4" 2,347
071.1D/512- 312 4/5 40 3/5 43 5/7 56 2/7 29 5/7 50 1/4 39 27 5/9 1 3 1 1/2 2x1 1/4" 2,866
080.1C/512- 348 5/6 41 8/9 51 63 4/7 29 5/7 60 2/3 39 27 5/9 1 3 1 1/2 2x 3" 3,121
080.1D/512- 348 5/6 41 8/9 51 63 4/7 29 5/7 60 2/3 39 27 5/9 1 1/4 4 1 1/2 2x 3" 3,483
Dimension A refers to distance between cooler and wall
8/14/2019 Guntner MAN
27/28www.guntnerus.com keep(s) your quality.08.07
DRAWING FOR ALL MODELS
8/14/2019 Guntner MAN
28/28
www.guntnerus.com
keep(s) your quality.