Radial Elbow 90°, 60°, 45°, 30° or Custom
Mounting Flange StandardsStraight DuctStraight Duct with Rectangular Straight TapStraight Duct with Rectangular Boot TapStraight Duct with Rectangular Conical Tap
Mitered Elbow 90°, 60°, 45°, 30° or Custom
34567
12131415161718
Concentric TransitionRectangular to Round Concentric TransitionOffset, VerticalOffset, HorizontalOffset, Double
1920
End CapCustom Fitting
2122
Damper Actuator WorksheetIndustrial Rectangular Parallel Blade Control Damper
2324
Industrial Rectangular Opposed Blade Control DamperIndustrial Rectangular Industrial Backdraft Damper
DUCT &FITTINGS
CONTROLDEVICES
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 REC002AG
Straight Duct with Rectangular Lateral Tap 8
Straight Duct with Round Tap 9
Straight Duct with Multiple Taps 10
Straight Duct with Multiple Taps 11
27Rectangular Horizontal Blastgate28Rectangular Vertical Blastgate
Contents
RECTANGULAR DUCT ORDER SHEET2
®
25Heavy Duty Rectangular Parallel Blade Control Damper26Heavy Duty Rectangular Opposed Blade Control Damper
WIDTH
12" - 24"
26" - 36"
38" - 48"
50" - 60"
62" - 72"
74" - 84"
86" - 96"
DUCT
ANGLE IRONMOUNTING
FLANGE
S = STIFFENER ADDEDTABLE BELOW IS FOR STANDARD DUCT LENGTH OF 48-1/4"
3” TO 4”
3” TO 4”
CENTERLINE TO CENTERLINE
CENTERLINETO
CENTERLINE
DUCT WIDTH
Mounting Flange Standards
NOTESFlange material is stainless steel.The number of holes for the bolt hole pattern is determined from the duct width and depth. Holeto hole distance will be calculated to be between 3" to 4". Oblong holes are punched along theflange centerline.Duct width or depth of 98" and larger requires engineering review and approval.Interior stiffeners (1” SCH40 pipe) are welded between duct sides 50" wide or greater. Separateoffset stiffeners are used when both duct width and depth are 50" or greater.
GAUGE
12
12
12
12 - S
12 - S
12 - S
12 - S
1.5”
2”
2”
2”
2”
2.5”
-12” W.G.
DUCT
2”
X
X
Angle sizes (X): 1.5", 2", 2.5", and 3.0"
DUCTDEPTH
Angle thickness for all sizes: 3/16"
Flange angle size determined fromduct width and system pressure.
WIDTH
12" - 24"
26" - 36"
38" - 48"
50" - 60"
62" - 72"
74" - 84"
86" - 96"
DUCT
SIZEANGLE
GAUGE
12
12
12
12 - S
12 - S
12 - S
12 - S
1.5”
2”
2”
2”
2”
2”
-10” W.G.
DUCT
2”
SIZEANGLE
GAUGE
14
14
14
14 - S
14 - S
14 - S
14 - S
1.5”
2”
2”
2”
2”
2”
-8” W.G.
DUCT
2”
SIZEANGLE
GAUGE
16
16
16
16 - S
16 - S
16 - S
16 - S
1.5”
2”
2”
2”
2”
2”
-6” W.G.
DUCT
1.5”
SIZEANGLE
GAUGE
12
12
12
12 - S
12 - S
12 - S
12 - S
1.5”
2”
2”
2”
2”
2.5”
-14” W.G.
DUCT
2”
SIZEANGLE
GAUGE
10
10
10
10 - S
10 - S
10 - S
10 - S
1.5”
2.5”
2”
2”
2.5”
2.5”
-16” W.G.
DUCT
2”
SIZEANGLE
GAUGE
10
10
10
10 - S
10 - S
10 - S
10 - S
2”
3.0”
2”
2”
2.5”
3.0”
-18” W.G.
DUCT
2”
SIZEANGLE
RECTANGULAR DUCT ORDER SHEET3
®
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/11/14 REC003AE
ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.
Y
L1
X
MAX. 48-1/4"
INTERIOR STIFFENER
RECTANGULAR DUCT ORDER SHEET
Straight Duct4
®
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 REC004AD
- L1 -DUCT
LENGTHQTYFITTING
NUMBERREMARKS
LONGER THAN STANDARD LENGTHS AND/OR HIGHERSYSTEM PRESSURES MAY REQUIRE ADDITIONALSTIFFENERS PER SMACNA, CONTACT FAB-TECH FORSPECIFIC GUIDELINES.
REMARKS:
COMPANY/JOB REFERENCE
- Y -DUCT
DEPTH
- X -DUCTWIDTH
OPTIONS
CUSTOM LENGTHS AVAILABLERAW END AVAILABLEDUCT WIDTH OR DEPTH OF 98" AND LARGER REQUIRESFAB-TECH ENGINEERING REVIEW AND APPROVALAN INTERIOR STIFFENER ( 1" SCH40 PIPE ) IS ADDED ATTHE MIDPOINT OF THE FLANGE FOR DUCT WIDTH ORDEPTH OF 50" AND GREATER
ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.
Straight Duct with Straight Rectangular Tap
RECTANGULAR DUCT ORDER SHEET5
®
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 REC005AD
- L1 -DUCT
LENGTHQTYFITTING
NUMBER
REMARKS:
COMPANY/JOB REFERENCE
- Y -DUCT
DEPTH
- X -DUCTWIDTH
LONGER THAN STANDARD LENGTHS AND/OR HIGHERSYSTEM PRESSURES MAY REQUIRE ADDITIONALSTIFFENERS PER SMACNA, CONTACT FAB-TECH FORSPECIFIC GUIDELINES.
OPTIONS
CUSTOM LENGTHS AVAILABLERAW END AVAILABLEDUCT WIDTH OR DEPTH OF 98" AND LARGER REQUIRESFAB-TECH ENGINEERING REVIEW AND APPROVALAN INTERIOR STIFFENER ( 1" SCH40 PIPE ) IS ADDED ATTHE MIDPOINT OF THE FLANGE FOR DUCT WIDTH ORDEPTH OF 50" AND GREATER
DUCT SPECIFICATIONS
- L2 -TAP
LENGTH
- L3 -LOCATE
TAP FROMD1 END
- L4 -LOCATE
TAP FROMTR
TAP SPECIFICATIONS
LOCATETAP
LEFT RIGHTTOP BOTTOM
*
SPECIFY SIDETO LOCATE TAP
- TX -TAP
WIDTH
- TY -TAP
DEPTH
L1 MAX. 48-1/4"
X
Y
L2MIN 6"
MIN 4"
L3
MIN 4"
L4
TOP
BOTTOM
LEFT RIGHT D1END
END VIEW D1
TR
L4
L4
L4
L4
TY
TX
ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.
- L1 -DUCT
LENGTHQTYFITTING
NUMBER
- Y -DUCT
DEPTH
- X -DUCTWIDTH
DUCT SPECIFICATIONS
Straight Duct with Rectangular Boot Tap
RECTANGULAR DUCT ORDER SHEET6
®
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 REC006AE
REMARKS:
COMPANY/JOB REFERENCE
LONGER THAN STANDARD LENGTHS AND/OR HIGHERSYSTEM PRESSURES MAY REQUIRE ADDITIONALSTIFFENERS PER SMACNA, CONTACT FAB-TECH FORSPECIFIC GUIDELINES.
OPTIONS
CUSTOM LENGTHS AVAILABLERAW END AVAILABLEDUCT WIDTH OR HEIGHT OF 98" AND LARGER REQUIRESFAB-TECH ENGINEERING REVIEW AND APPROVALAN INTERIOR STIFFENER ( 1" SCH40 PIPE ) IS ADDED ATTHE MIDPOINT OF THE FLANGE FOR DUCT WIDTH ORHEIGHT OF 50" AND GREATER
- L2 -TAP
LENGTH
- L3 -LOCATE
TAP FROMD1 END
- L4 -LOCATE
TAP FROMTR
TAP SPECIFICATIONS
LOCATETAP
LEFT RIGHTTOP BOTTOM
*
SPECIFY SIDETO LOCATE TAP
- TY -TAP
DEPTH
- TX -TAP
WIDTH
L1 MAX. 48-1/4"
X
Y
L2
9" STD MIN 4"
L3
MIN 4"
L4
TOP
BOTTOM
LEFT RIGHT D1END
END VIEW D1
TR
L4
L4
L4
L4
TY
TX
45°6”STD
ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.
- L1 -DUCT
LENGTHQTYFITTING
NUMBER
- Y -DUCT
DEPTH
- X -DUCTWIDTH
DUCT SPECIFICATIONS
Straight Duct with Rectangular Conical Tap
RECTANGULAR DUCT ORDER SHEET7
®
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 REC007AE
REMARKS:
COMPANY/JOB REFERENCE
LONGER THAN STANDARD LENGTHS AND/OR HIGHERSYSTEM PRESSURES MAY REQUIRE ADDITIONALSTIFFENERS PER SMACNA, CONTACT FAB-TECH FORSPECIFIC GUIDELINES.
OPTIONS
CUSTOM LENGTHS AVAILABLERAW END AVAILABLEDUCT WIDTH OR DEPTH OF 98" AND LARGER REQUIRESFAB-TECH ENGINEERING REVIEW AND APPROVALAN INTERIOR STIFFENER ( 1" SCH40 PIPE) IS ADDED ATTHE MIDPOINT OF THE FLANGE FOR DUCT WIDTH ORDEPTH OF 50" AND GREATER
- L2 -TAP
LENGTH
- L3 -LOCATE
TAP FROMD1 END
- L4 -LOCATE
TAP FROMTR
TAP SPECIFICATIONS
LOCATETAP
LEFT RIGHTTOP BOTTOM
*
SPECIFY SIDETO LOCATE TAP
- TY -TAP
DEPTH
- TX -TAP
WIDTH
L1 MAX. 48-1/4"
X
Y
L2
9" STD
MIN 4"
L3
MIN 4"
L4
TOP
BOTTOM
LEFT RIGHT D1END
END VIEW D1
TR
L4
L4
L4
L4
TY
TX
45°6”STD
ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.
- L1 -DUCT
LENGTHQTYFITTING
NUMBER
- Y -DUCT
DEPTH
- X -DUCTWIDTH
DUCT SPECIFICATIONS
TY
Straight Duct with Rectangular Lateral Tap
6” STD
RECTANGULAR DUCT ORDER SHEET8
®
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 REC008AE
LONGER THAN STANDARD LENGTHS AND/OR HIGHERSYSTEM PRESSURES MAY REQUIRE ADDITIONALSTIFFENERS PER SMACNA, CONTACT FAB-TECH FORSPECIFIC GUIDELINES.
REMARKS:
COMPANY/JOB REFERENCE
OPTIONS
CUSTOM LENGTHS AVAILABLERAW END AVAILABLEDUCT WIDTH OR DEPTH OF 98" AND LARGER REQUIRESFAB-TECH ENGINEERING REVIEW AND APPROVALAN INTERIOR STIFFENER ( 1" SCH40 PIPE ) IS ADDED ATTHE MIDPOINT OF THE FLANGE FOR DUCT WIDTH ORHEIGHT OF 50" AND GREATER
TX
L2
45°STD
- L2 -TAP
LENGTH
- L3 -LOCATE
TAP FROMD1 END
- L4 -LOCATE
TAP FROMTR
TAP SPECIFICATIONS
LOCATETAP
LEFT RIGHTTOP BOTTOM
*
SPECIFY SIDETO LOCATE TAP
- TY -TAP
DEPTH
- TX -TAP
WIDTH
L1 MAX. 48-1/4"
X
Y
L4
TOP
BOTTOM
LEFT RIGHT D1END
END VIEW D1
TR
L4
L4
L4
L4
MIN 4"
L3
MIN 4"
ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.
L1 MAX. 48-1/4"
RDØ
X
Y
L2MIN 6"
Straight Duct with Round Tap
RECTANGULAR DUCT ORDER SHEET9
®
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 REC009AG
REMARKS:
COMPANY/JOB REFERENCE
MIN 4"
L3
MIN 4"
LONGER THAN STANDARD LENGTHS AND/OR HIGHER SYSTEMPRESSURES MAY REQUIRE ADDITIONAL STIFFENERS PER SMACNA,CONTACT FAB-TECH FOR SPECIFIC GUIDELINES.
OPTIONS
CUSTOM LENGTHS AVAILABLERAW END AVAILABLEDUCT WIDTH OR DEPTH OF98" AND LARGER REQUIRESFAB-TECH ENGINEERINGREVIEW AND APPROVALAN INTERIOR STIFFENER( 1" SCH40 PIPE ) IS ADDED ATTHE MIDPOINT OF THE FLANGEFOR DUCT WIDTH OR DEPTHOF 50" AND GREATER
L4
- L1 -DUCT
LENGTHQTYFITTING
NUMBER
- Y -DUCT
DEPTH
- X -DUCTWIDTH
DUCT SPECIFICATIONS
EZ
BI
SC
SS
EZ CLAMPS( AVAILABLE 4" - 14" )
STAINLESS CAST RINGS( AVAILABLE 4" - 14" )
BLACK IRON ANGLE RINGS( AVAILABLE 4" - 100" )
STAINLESS ANGLE RINGS( AVAILABLE 16" - 120" )
ROUND RING TYPES
- L2 -TAP
LENGTH
- L3 -LOCATE
TAP FROMD1 END
- L4 -LOCATE
TAP FROMTR
TAP SPECIFICATIONS
"DØ"TAPDIA.
"R"TAP
RINGTYPE
LOCATETAP
LEFT RIGHTTOP BOTTOM
*
SPECIFY SIDETO LOCATE TAP
TOP
BOTTOM
LEFT RIGHT D1END
END VIEW D1
TR
L4
L4
L4
L4
ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.
Straight Duct with Multiple Taps
RECTANGULAR DUCT ORDER SHEET10
®
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 REC010AH
LONGER THAN STANDARD LENGTHS AND/OR HIGHERSYSTEM PRESSURES MAY REQUIRE ADDITIONALSTIFFENERS PER SMACNA, CONTACT FAB-TECH FORSPECIFIC GUIDELINES.
REMARKS:
COMPANY/JOB REFERENCE
OPTIONS
CUSTOM LENGTHS AVAILABLERAW END AVAILABLEDUCT WIDTH OR DEPTH OF 98" AND LARGER REQUIRESFAB-TECH ENGINEERING REVIEW AND APPROVALAN INTERIOR STIFFENER (1" SCH40 PIPE) IS ADDED AT THEMIDPOINT OF THE FLANGE FOR DUCT WIDTH OR DEPTHOF 50" AND GREATER
RTXTX
6" STD
4"MIN
4"MIN
1" MIN
6" STD
SHOETAP
L3STRAIGHTTAP
L3
CONICAL TAPL3
ROUND TAPL3
45° LATERAL TAPL3
L1
L2L2
EZ
BI
SC
SS
EZ CLAMPS( AVAILABLE 4" - 14" )
STAINLESS CAST RINGS( AVAILABLE 4" - 14" )
BLACK IRON ANGLE RINGS( AVAILABLE 4" - 100" )
STAINLESS ANGLE RINGS( AVAILABLE 16" - 120" )
ROUND RING TYPESL4
X
Y
MIN 6"
TY
TXTX
L5
L5
L4
L2L2
L2
L2
END VIEW D1
MAX. 48-1/4"
4"MIN
TX
DØ
45°
D1END
TOP
BOTTOM
LEFT RIGHT
TR
ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.
Straight Duct with Multiple Taps
RECTANGULAR DUCT ORDER SHEET11
®
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 REC011AC
REMARKS:
COMPANY/JOB REFERENCE
- L1 -DUCT
LENGTHQTYFITTING
NUMBER
- Y -DUCT
DEPTH
- X -DUCTWIDTH
REMARKS
DUCT SPECIFICATIONS
- L2 -TAP
LENGTH
TAP#1
- TY -TAP
DEPTH
- TX -TAP
WIDTH
- L3 -LOCATE TAP
FROM D1 END
- L4 -LOCATE
HORIZONTAL TAPFROM TR
TAP SPECIFICATIONS
"DØ"TAPDIA.
SELECT TAP TYPE: STRAIGHT: BOOT: CONICAL: LATERAL: ROUND:
SPECIFYLOCATION
OF TAP
LEFT RIGHT
TOP
BOTTOM
- L5 -LOCATE
VERTICAL TAPFROM TR
"R"TAP
RINGTYPE
TAP#2
SELECT TAP TYPE: STRAIGHT: BOOT: CONICAL: LATERAL: ROUND:
LEFT RIGHT
TOP
BOTTOM
TAP#3
SELECT TAP TYPE: STRAIGHT: BOOT: CONICAL: LATERAL: ROUND:
LEFT RIGHT
TOP
BOTTOM
TAP#4
SELECT TAP TYPE: STRAIGHT: BOOT: CONICAL: LATERAL: ROUND:
LEFT RIGHT
TOP
BOTTOM
TAP#5
SELECT TAP TYPE: STRAIGHT: BOOT: CONICAL: LATERAL: ROUND:
LEFT RIGHT
TOP
BOTTOM
TAP#6
SELECT TAP TYPE: STRAIGHT: BOOT: CONICAL: LATERAL: ROUND:
LEFT RIGHT
TOP
BOTTOM
TAP#7
SELECT TAP TYPE: STRAIGHT: BOOT: CONICAL: LATERAL: ROUND:
LEFT RIGHT
TOP
BOTTOM
TAP#8
SELECT TAP TYPE: STRAIGHT: BOOT: CONICAL: LATERAL: ROUND:
LEFT RIGHT
TOP
BOTTOM
TAP#9
SELECT TAP TYPE: STRAIGHT: BOOT: CONICAL: LATERAL: ROUND:
LEFT RIGHT
TOP
BOTTOM
ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.
90°
60°
45°
30°
- L1 -THROATRADIUS
- N -CUSTOMANGLE
X
Y
N
L1
- N -ELBOWANGLE
90°, 60°, 45°, 30° or Custom Elbow
- Y -DUCTWIDTH
QTY- X -
DUCTDEPTH
FITTINGNUMBER
REMARKS
30° RADIALELBOW
60° RADIALELBOW
45° RADIALELBOW
RECTANGULAR DUCT ORDER SHEET
COMPANY/JOB REFERENCE
REMARKS:
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 REC012AD
12®
NOTES
RAW END AVAILABLE.DUCT WIDTH OR DEPTH OF 98" AND LARGER REQUIRES FAB-TECHENGINEERING REVIEW.AN INTERIOR STIFFENER ( 1" SCH40 PIPE ) IS ADDED AT THE MIDPOINT OFTHE FLANGE FOR DUCT WIDTH OR DEPTH OF 50" AND GREATER.
90° RADIALELBOW
90°
60°
45°
30°
90°
60°
45°
30°
90°
60°
45°
30°
90°
60°
45°
30°
90°
60°
45°
30°
90°
60°
45°
30°
ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.
- L2 -THROATLENGTH
- L1 -THROATLENGTH
- N -CUSTOMANGLE
90°
60°
45°
30°
- N -ELBOWANGLE
REMARKS
X
Y
L1
L2
N
90°, 60°, 45°, 30° or Custom Mitered Elbow
- X -DUCTWIDTH
QTY- Y -
DUCTDEPTH
FITTINGNUMBER
30° MITEREDELBOW
60° MITEREDELBOW
90° MITEREDELBOW
RECTANGULAR DUCT ORDER SHEET
COMPANY/JOB REFERENCE
REMARKS:
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 REC013AD
13®
45° MITEREDELBOW
NOTES
RAW END AVAILABLE.DUCT WIDTH OR DEPTH OF 98" AND LARGERREQUIRES FAB-TECH ENGINEERING REVIEW.AN INTERIOR STIFFENER ( 1" SCH40 PIPE ) IS ADDED ATTHE MIDPOINT OF THE FLANGE FOR DUCT WIDTH ORDEPTH OF 50" AND GREATER.
90°
60°
45°
30°
90°
60°
45°
30°
90°
60°
45°
30°
90°
60°
45°
30°
90°
60°
45°
30°
90°
60°
45°
30°
ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.
- T2 -TRANSITION
DEPTH
- T1 -TRANSITION
WIDTH
T1
YT2
X
L1
- L1 -DUCT
LENGTH
Concentric Transition
- X -DUCTWIDTH
QTY- Y -
DUCTDEPTH
FITTINGNUMBER
REMARKS
RECTANGULAR DUCT ORDER SHEET
COMPANY/JOB REFERENCE
REMARKS:
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 REC014AD
14®
FOR ECCENTRIC RECTANGULARTO RECTANGULAR FITTING, USETHE CUSTOM FITTING ORDERSHEET.
NOTES
RAW END AVAILABLE.DUCT WIDTH OR DEPTH OF 98" AND LARGER REQUIRES FAB-TECH ENGINEERING REVIEW.AN INTERIOR STIFFENER ( 1" SCH40 PIPE ) IS ADDED AT THE MIDPOINT OF THE FLANGE FOR DUCTWIDTH OR DEPTH OF 50" AND GREATER.
ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.
Concentric Rectangular to Round Transition
REMARKS- L2 -
THROATLENGTH
- R -RINGTYPE
- DØ -ROUND
DIAMETER
Y
DØ
X L1
3" MIN
R
L2
- L1 -DUCT
LENGTH
- X -DUCTWIDTH
QTY- Y -
DUCTDEPTH
FITTINGNUMBER
RECTANGULAR DUCT ORDER SHEET
COMPANY/JOB REFERENCE
REMARKS:
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 REC015AG
15®
FOR ECCENTRIC RECTANGULARTO ROUND FITTING, USE THECUSTOM FITTING ORDER SHEET.
EZ
BI
SC
SS
EZ CLAMPS( AVAILABLE 4" - 14" )
STAINLESS CAST RINGS( AVAILABLE 4" - 14" )
BLACK IRON ANGLE RINGS( AVAILABLE 4" - 100" )
STAINLESS ANGLE RINGS( AVAILABLE 16" - 120" )
ROUND RING TYPES
NOTES
RAW END AVAILABLE.DUCT WIDTH OR DEPTH OF 98" AND LARGER REQUIRES FAB-TECH ENGINEERING REVIEW.AN INTERIOR STIFFENER ( 1" SCH40 PIPE ) IS ADDED AT THE MIDPOINT OF THE FLANGE FOR DUCTWIDTH OR DEPTH OF 50" AND GREATER.
ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.
L1
L2
X
Y
- L2 -VERTICALOFFSET
- L1 -DUCT
LENGTH
CENTER OF - Y -TO CENTER OF
OFFSET
Vertical Offset
REMARKS- X -
DUCTWIDTH
QTY- Y -
DUCTDEPTH
FITTINGNUMBER
RECTANGULAR DUCT ORDER SHEET
COMPANY/JOB REFERENCE
REMARKS:
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 REC016AD
16®
NOTES
RAW END AVAILABLE.DUCT WIDTH OR DEPTH OF 98" AND LARGER REQUIRES FAB-TECH ENGINEERING REVIEW.AN INTERIOR STIFFENER ( 1" SCH40 PIPE ) IS ADDED AT THE MIDPOINT OF THE FLANGE FOR DUCTWIDTH OR DEPTH OF 50" AND GREATER.
ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.
- L2 -HORIZONTAL
OFFSET
- L1 -DUCT
LENGTH
Y
X
L1L2CENTER OF - X -TO CENTER OF
OFFSET
Horizontal Offset
REMARKS- X -
DUCTWIDTH
QTY- Y -
DUCTDEPTH
FITTINGNUMBER
RECTANGULAR DUCT ORDER SHEET
COMPANY/JOB REFERENCE
REMARKS:
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 REC017AD
17®
NOTES
RAW END AVAILABLE.DUCT WIDTH OR DEPTH OF 98" AND LARGER REQUIRESFAB-TECH ENGINEERING REVIEW.AN INTERIOR STIFFENER ( 1" SCH40 PIPE ) IS ADDED AT THEMIDPOINT OF THE FLANGE FOR DUCT WIDTH OR DEPTHOF 50" AND GREATER.
ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.
REMARKS- L3 -
HORIZONTALOFFSET
- L2 -VERTICALOFFSET
L3
L1
L2
Y
X
Double Offset
- X -DUCTWIDTH
QTY- Y -
DUCTDEPTH
FITTINGNUMBER
- L1 -DUCT
LENGTH
CENTER OF - X -TO CENTER OF
OFFSETCENTER OF - Y -TO CENTER OF
OFFSET
RECTANGULAR DUCT ORDER SHEET
COMPANY/JOB REFERENCE
REMARKS:
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 REC018AD
18®
NOTES
RAW END AVAILABLE.DUCT WIDTH OR DEPTH OF 98" AND LARGER REQUIRES FAB-TECH ENGINEERING REVIEW.AN INTERIOR STIFFENER ( 1" SCH40 PIPE ) IS ADDED AT THE MIDPOINT OF THE FLANGE FOR DUCTWIDTH OR DEPTH OF 50" AND GREATER.
ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.
Y
X
STAINLESS STEELPLATE WELDEDTO FLANGE
End Cap
FITTING THAT END CAPWILL BE ATTACHED TO:DUCT FITTING NUMBER
REMARKS- X -
DUCTWIDTH
QTY- Y -
DUCTDEPTH
FITTINGNUMBER
RECTANGULAR DUCT ORDER SHEET
COMPANY/JOB REFERENCE
REMARKS:
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 REC019AD
19®
NOTES
FLANGE MATERIAL WILL BE STAINLESS STEEL UNLESS OTHER MATERIAL IS SPECIFIED.DUCT WIDTH OR DEPTH OF 98" AND LARGER REQUIRES FAB-TECH ENGINEERING REVIEW.A STIFFENER ( ANGLE MATERIAL MATCHING THE FRAME ) IS ADDED AT THE FLANGE MIDPOINT OR WHERE AESTHETICALLYPLEASING FOR DUCT WIDTH OR DEPTH OF 50" AND GREATER ( AS REQUIRED TO MEET MAXIMUM 4' SPACING ).
ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.
RECTANGULAR DUCT ORDER SHEET
Custom Fitting20
®
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 REC020AE
QTYFITTINGNUMBER
REMARKS
COMPANY/JOB REFERENCE
NOTESDUCT WIDTH OR DEPTH OF 98" AND LARGER REQUIRES FAB-TECH ENGINEERINGREVIEW.AN INTERIOR STIFFENER ( 1" SCH40 PIPE ) IS ADDED AT THE MIDPOINT OF THE FLANGE FORDUCT WIDTH OR DEPTH OF 50" AND GREATER.
ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.
ACTUATOR TYPE:
Pneumatic
Electric
Available Air Pressure
Voltage
Spring Return
Double Acting
Limit Switch
Fail Open
Fail Closed
1 Switch
2 Switch
Positioner
Position Indicator
Manual Override Gearbox
Solenoid Valves
Damper Actuator Worksheet
RECTANGULAR DUCT ORDER SHEET
COMPANY/JOB REFERENCE
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 REC021AC
21®
Feedback Potentiometer
REMARKS:
DAMPER SIZE:
Preferred Actuator - Make and Model Number:
Accessory Part Number:
CUSTOMER SELECTED:
TORQUE
25010001600
ISOLATION DAMPER
SIZE
Ø4" - Ø14"Ø16" - Ø48"Ø50" AND LARGER
RECOMMENDED MINIMUMOPEN/CLOSE TORQUE
( inch pounds )
RECTANGULAR DAMPER
1000LONGEST SIDEUP TO 48"
ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.
L1
IF L1 OR L2 ARE LARGER THAN 36", HEAVY DUTY DAMPER IS REQUIRED.
8"STD
L2
Industrial Rectangular Parallel BladeControl Damper
OPTIONSACTUATOR MOUNTING KITS
PNEUMATIC/ELECTRIC ACTUATORGEAR DRIVE WITH LOCKING DAMPER SHAFT
SPECIFICATIONSFRAME 8" STANDARD LENGTH WITH 2" FLANGESMOUNTING HOLES (.44” x .69” SLOT)LOCATED BETWEEN 3" TO 4" ON CENTERBLADES - 10 GA STAINLESS STEELAXLES - .50" DIAMETER STAINLESS STEELLIQUID TIGHT SHAFT SEALSLINKAGES LOCATED OUTSIDE THEAIRSTREAM - 10 GA STAINLESS STEEL
STEELQUADRANT LEVER - .25” STAINLESS STEELFULL OPEN / FULL CLOSE LOCKOUTSPTFE FRAME SEALS
- L1-WIDTH
QTY - L2 -DEPTH
FITTINGNUMBER
RECTANGULAR DUCT ORDER SHEET
COMPANY/JOB REFERENCE
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 REC022AF
22®
TWIN DRIVE AS REQUIREDQUADRANT PLATES - 10 GA STAINLESS
REMARKS:
REMARKS
ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.
BLANK MOUNTING KIT ( PLATE & SHAFT ADAPTER )FOR CUSTOMER SUPPLIED ACTUATOR
L1 8"STD
L2
SPECIFICATIONS
BLADES - 10 GAUGE STAINLESS STEEL
LINKAGES LOCATED OUTSIDE THEAIRSTREAM - 10 GA STAINLESS STEELTWIN DRIVE AS REQUIRED
FULL OPEN / FULL CLOSE LOCKOUTS
MOUNTING HOLES ( .44" X .69" SLOT )EQUAL TO OR LESS THAN 4" ON CENTER
FRAME 8" STD LENGTH WITH 2" FLANGES
PTFEFRAME SEALS
LIQUID TIGHT SHAFT SEALS
QUADRANT LEVER - .25" STAINLESS STEEL
AXLES - .50" DIAMETER STAINLESS STEEL
QUADRANT PLATES - 10 GA STAINLESS STEEL
Industrial Rectangular Opposed BladeControl Damper
- L1 -WIDTHQTY - L2 -
DEPTHFITTINGNUMBER
RECTANGULAR DUCT ORDER SHEET
COMPANY/JOB REFERENCE
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 REC023AF
23®
REMARKS:
REMARKS
ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.
OPTIONSACTUATOR MOUNTING KITS
PNEUMATIC/ELECTRIC ACTUATORGEAR DRIVE WITH LOCKING DAMPER SHAFT
BLANK MOUNTING KIT ( PLATE & SHAFT ADAPTER )FOR CUSTOMER SUPPLIED ACTUATOR
IF L1 OR L2 ARE LONGER THAN 36", HEAVY DUTY DAMPER IS REQUIRED.
L1 8"STD
L2
SPECIFICATIONS10 GA STAINLESS STEEL FRAME8" STD LENGTH WITH 2" FLANGESCENTER SUPPORT AS REQUIRED
MANUAL ADJUSTABLECOUNTERWEIGHTS
FLANGE MOUNTING HOLES( .44" X .69" SLOT ) EQUAL TO ORLESS THAN 4" ON CENTER
14 GA STAINLESS STEEL BLADES.50" DIAMETER STAINLESSSTEEL AXLESLIQUID TIGHT SHAFT SEALSALL LINKAGES 10 GA STAINLESSSTEEL OUTSIDE AIRSTREAM
CENTER SUPPORT REQUIRED FORBLADES LONGER THAN 36" ( "L1" ) COUNTERWEIGHT
PTFE FRAME SEALS
Industrial Rectangular Backdraft Damper
- L1 -WIDTHQTY - L2 -
DEPTHFITTINGNUMBER
REMARKS
RECTANGULAR DUCT ORDER SHEET
COMPANY/JOB REFERENCE
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 REC024AD
24®
REMARKS:
ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.
L1
L2
Heavy Duty Rectangular Parallel BladeControl Damper
OPTIONSACTUATOR MOUNTING KITSPNEUMATIC/ELECTRIC ACTUATORGEAR DRIVE WITH LOCKING DAMPER SHAFT
SPECIFICATIONSFRAME 10" STANDARD LENGTH WITH2" FLANGESMOUNTING HOLES (.44” x .69” SLOT)LOCATED BETWEEN 3" TO 4" ON CENTERBLADES - 10 GA STAINLESS STEELAXLES - 1.38" DIAMETER STAINLESS STEELLIQUID TIGHT SHAFT SEALSLINKAGES LOCATED OUTSIDE THEAIRSTREAM - 10 GA STAINLESS STEEL
STEELQUADRANT LEVER - .25” STAINLESS STEELFULL OPEN / FULL CLOSE LOCKOUTSPTFE FRAME SEALS
- L1-WIDTH
QTY - L2 -DEPTH
FITTINGNUMBER
RECTANGULAR DUCT ORDER SHEET
COMPANY/JOB REFERENCE
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 REC025AF
25®
TWIN DRIVE AS REQUIREDQUADRANT PLATES - 10 GA STAINLESS
REMARKS:
®PIN-LOCK PIN ( KEYED MASTERLOCKBODY SOLD SEPARATELY )
REMARKS
ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.
CENTER SUPPORT W/ CENTER LINKAGEREQUIRED FOR BLADES LONGER THAN 36" ("L1").
10"STD
- L1 -WIDTHQTY - L2 -
DEPTHFITTINGNUMBER
REMARKS
RECTANGULAR DUCT ORDER SHEET
COMPANY/JOB REFERENCE
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 REC026AF
26®
REMARKS:
ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.
Heavy Duty Rectangular Opposed BladeControl Damper
OPTIONS
Frame 10" standard length with 2" flanges.Mounting holes (.44" x .69" slot)located between 3" to 4" on center.Blades - 10 GA stainless steel.Axles - 1.38" diameter stainless steel.Liquid tight shaft seals.Linkage located outside theairstream - 10 GA stainless steeltwin drive as required.Quadrant plates - 10 GA stainlesssteel.Quadrant lever - .25" stainless steel.Full open / full close lockouts.PTFE frame seals.
SPECIFICATIONS
NOTEAll fittings with standard Fab-Tech connectionsinclude gaskets and clamps or hardware asrequired for installation.
Actuator mounting kits.Blank mounting kit ( plate & shaft adapter ) forcustomer supplied actuator.Pneumatic / electric actuator.Gear drive with locking damper shaft.
CENTER SUPPORT W/ CENTER LINKAGEREQUIRED FOR BLADES LONGER THAN 36" ("L1").
10"STD
L1
L2
L1
8"STD
CENTER SUPPORT REQUIRED FORBLADES LONGER THAN 36" ( "L1" )
Horizontal Blastgate
- L1 -WIDTHQTY - L2 -
DEPTHFITTINGNUMBER
RECTANGULAR DUCT ORDER SHEET
COMPANY/JOB REFERENCE
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 REC027AA
27®
SPECIFICATIONSSTAINLESS STEEL BODY, RINGSAND BLADESBLADE LOCKOUT SYSTEM
PTFE WIPER( TYP BOTHSIDES OFBLADE)
L2
BLADE
COLLAR
BODY
SPACER
BLADELOCKOUT(STD)
REMARKS:
REMARKS
ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.
L1
8"STD
CENTER SUPPORT REQUIRED FORBLADES LONGER THAN 36" ( "L1" )
Vertical Blastgate
- L1 -WIDTHQTY - L2 -
DEPTHFITTINGNUMBER
REMARKS
RECTANGULAR DUCT ORDER SHEET
COMPANY/JOB REFERENCE
Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com
© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 REC028AA
28®
SPECIFICATIONSSTAINLESS STEEL BODY, RINGSAND BLADESBLADE LOCKOUT SYSTEM
PTFE WIPER( TYP BOTHSIDES OFBLADE)
L2
BLADE
COLLAR
BODY
SPACER
BLADELOCKOUT(STD)
REMARKS: