For more information, visit commscope.com1
The generic closure FIST-GCO2 is an environmentally sealed enclosure for the FIST fiber management system allowing splicing and passive component integration in the external network.
Features• Single-ended design
• Base and dome sealed with clamp and O-ring system
• 6, 8 or 16 round entry/exit ports for drop cables and 1 or 2 oval ports for looped cable
• UMS (universal mounting system) profiles provide foundation for mounting combinations of SOSA2 (splice only sub-assembly) and/or SASA3 (splitter array sub-assembly) modules, which consist of a modular grooveplate and trays
• Compatible with most common cable types: e.g. loose tube, central core, ribbon fiber
• Uncut fibers can be stored as single circuits in trays and/or as cable elements in storage space between profiles.
• Storage baskets available for mass storage of fibers of central core cable constructions.
• Closure can be used in aerial, pedestal and underground (up to 5 meters) environments
FIST-GCO2FIST Generic Closure Organizer
For more information, visit commscope.com
FIST-GCO2FIST Generic Closure Organizer
2
TH
IS D
RA
WIN
G I
S A
CO
NT
RO
LL
ED
DO
CU
ME
NT
1 PLC0 PLC
2 PLC3 PLC4 PLC
DIMENSIONS: TOLERANCES UNLESSOTHERWISE SPECIFIED:
USED ON
LTR APVDDATEREVISION RECORD DWN
DW
G N
O
SIZEOF
C
12345678
A
B
DRAWING NO
D
SHEET REV
APVD
DWN
CHK
NAME
SCALE
MATERIAL HEAT TREAT
ANGLES
SURFACE TEXTURE
3306-7 (3/13)
A3THIS
INFO
RM
ATIO
N IS
CO
NFI
DEN
TIAL
AN
D P
RO
PRIE
TAR
Y TO
TYC
OEL
ECTR
ON
ICS
CO
RPO
RAT
ION
AN
D IT
S W
OR
LDW
IDE
SUBS
IDIA
RIE
SAN
D A
FFIL
IATE
S (T
E).
IT M
AY N
OT
BE D
ISC
LOSE
D T
O A
NYO
NE,
O
THER
TH
AN T
E PE
RSO
NN
EL, W
ITH
OU
T AU
THO
RIZ
ATIO
N F
RO
M T
E (w
ww
.TE.
com
).
TE Connectivity
STEVEN
ST
EV
EN
--
--
--
3:10 1 1
--
--
mm-----
1
-
-
steven.drw-
Dimensions and capacities Key1 Dome2 Clamp3 Base4 Wrap-around grooveplates
1
L
2
3
4
THIS DRAWING IS A CONTROLLED DOCUMENT
1 P
LC
0 P
LC
2 P
LC
3 P
LC
4 P
LC
DIM
EN
SIO
NS
:T
OLE
RA
NC
ES
UN
LE
SS
OT
HE
RW
ISE
SP
EC
IFIE
D:
US
ED
ON
LT
RA
PV
DD
AT
ER
EV
ISIO
N R
EC
OR
DD
WN
DWG NO
SIZ
EO
F
C
12
34
56
78
A B
DR
AW
ING
NO
D
SH
EE
TR
EV
AP
VD
DW
N
CH
K
NA
ME
SC
ALE
MA
TE
RIA
LH
EA
T T
RE
AT
AN
GLE
S
SU
RF
AC
E T
EX
TU
RE
3306-7
(3/1
3)
A3
THIS INFORMATION IS CONFIDENTIAL AND PROPRIETARY TO TYCOELECTRONICS CORPORATION AND ITS WORLDWIDE SUBSIDIARIESAND AFFILIATES (TE). IT MAY NOT BE DISCLOSED TO ANYONE, OTHER THAN TE PERSONNEL, WITHOUT AUTHORIZATION FROM TE (www.TE.com).
TE
Connectivity
ST
EV
EN
STEVEN
--
--
--
3:101
1
----
mm
-----1
-
-
steven.drw-
THIS DRAWING IS A CONTROLLED DOCUMENT
1 P
LC
0 P
LC
2 P
LC
3 P
LC
4 P
LC
DIM
EN
SIO
NS
:T
OL
ER
AN
CE
S U
NL
ES
SO
TH
ER
WIS
E S
PE
CIF
IED
:
US
ED
ON
LT
RA
PV
DD
AT
ER
EV
ISIO
N R
EC
OR
DD
WN
DWG NO
SIZ
EO
F
C
12
34
56
78
AB
DR
AW
ING
NO
D
SH
EE
TR
EV
AP
VD
DW
N
CH
K
NA
ME
SC
AL
E
MA
TE
RIA
LH
EA
T T
RE
AT
AN
GL
ES
SU
RF
AC
E T
EX
TU
RE
33
06
-7 (
3/1
3)
A3
THIS INFORMATION IS CONFIDENTIAL AND PROPRIETARY TO TYCOELECTRONICS CORPORATION AND ITS WORLDWIDE SUBSIDIARIESAND AFFILIATES (TE). IT MAY NOT BE DISCLOSED TO ANYONE, OTHER THAN TE PERSONNEL, WITHOUT AUTHORIZATION FROM TE (www.TE.com).
TE
Con
nect
ivity
ST
EV
EN
STEVEN
--
--
--
3:10
11
- -- -
mm
- - - - -1
-
-
stev
en.d
rw-
TH
IS D
RA
WIN
G I
S A
CO
NT
RO
LL
ED
DO
CU
ME
NT
1 PLC0 PLC
2 PLC3 PLC4 PLC
DIMENSIONS: TOLERANCES UNLESSOTHERWISE SPECIFIED:
USED ON
LTR APVDDATEREVISION RECORD DWN
DW
G N
O
SIZEOF
C
12345678
A
B
DRAWING NO
D
SHEET REV
APVD
DWN
CHK
NAME
SCALE
MATERIAL HEAT TREAT
ANGLES
SURFACE TEXTURE
3306-7 (3/13)
A3THIS
INFO
RM
ATIO
N IS
CO
NFI
DEN
TIAL
AN
D P
RO
PRIE
TAR
Y TO
TYC
OEL
ECTR
ON
ICS
CO
RPO
RAT
ION
AN
D IT
S W
OR
LDW
IDE
SUBS
IDIA
RIE
SAN
D A
FFIL
IATE
S (T
E).
IT M
AY N
OT
BE D
ISC
LOSE
D T
O A
NYO
NE,
O
THER
TH
AN T
E PE
RSO
NN
EL, W
ITH
OU
T AU
THO
RIZ
ATIO
N F
RO
M T
E (w
ww
.TE.
com
).
TE Connectivity
STEVEN
ST
EV
EN
--
--
--
3:10 1 1
--
--
mm-----
1
-
-
steven.drw-
B
A
C
D
B*
A
D
B**
C CC
A
B
GCO2-BC GCO2-BD GCO2-BE
Closure dimensions in mm Length (L) 488 566 680 Width at base (D) 247 247 247Width at base with clamp 285 285 285
Cable port dimensions in mm Oval port (A/C) 30/82 30/82 30/82 Round ports (B/B*/B**) 30 (20/13.5) 30 (20/13.5) 30 (20/13.5)
Cable port capacity in mm Oval port (2 cables/port) Minimum Ø 2x12 2x12 2x12 Maximum Ø 2x25 2x25 2x25 6/8 round ports (1 cable/port) Minimum Ø 5 5 5 Maximum Ø 30 30 30 16 round ports (1 cable/port) Minimum Ø 5 5 5 Maximum Ø 20 20 20
Splice capacity Fibers Trays Fibers Trays Fibers Trays
Single circuit splicing 112 56 160 80 224 112 (2 primary coated fibvers)
Single element splicing 336 28 480 40 672 56 (12 primary coated fibers)
Ribbon fiber splicing (4/8-fibers) 224 28 336 42 464 58
Ribbon fiber splicing (12-fiber) 192 16 336 28 432 36
Capacities shown above are based on use of FIST-SOSA2 trays; capacity can be increased by the use of FIST-SOSA2-5SE modules or FIST-SOSA2-SLE trays. Please contact your local CommScope sales representative for more information.
NOTE: Use of the FIST-SOSA2-SLE limits fiber length and allowable bend radius.
www.commscope.comVisit our website or contact your local CommScope representative for more information.
© 2015 CommScope, Inc. All rights reserved.
FIST and all trademarks identified by ® or ™ are registered trademarks or trademarks, respectively, of CommScope, Inc. This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to CommScope products or services.
PS-318885.3-EU (12/15)
FIST-GCO2FIST Generic Closure Organizer
Ordering Information
FIST-GCO2- ____ __ - __ __
Closure size
BC 488 mm long with (2) 28 unit UMS
BD 566 mm long with (2) 42 unit UMS
BE 680 mm long with (2) 58 unit UMS
Number of ports
6 Round ports (6: ø 30) + 1 oval port
8 Round ports (8: ø 30) + 2 oval ports
16 Round ports (8 : ø 20) + 1 oval port (8 : ø 13.5)
Flash test valve
V Pre-installed flash test valve
N No flash test valve
Ground feed-through
G Pre-installed ground feedthrough
N No ground feedthrough
For more technical options and order quantity information, please consult the product ordering guide or your local sales representative.
FOSC 400Fiber Optic Splice Closures
commscope.com2
FOSC 400 - Fiber Optic Splice Closures The FOSC name is synonymous with excellence in sealing, fiber management, ease of use and design flexibility. The original FOSC 100 was introduced in 1986 and has held a leadership position since that time. FOSC closures are engineered specially for fiber-optic applications. They are not modified copper closures and the difference shows. FOSC clients ask for and get the highest quality standards.
FOSC 400 closures combine proven fiber management hardware from the earlier FOSC 100 closures, with a completely new sealing system. Base-to-dome seals on FOSC 400 are mechanical for ease of installation and re-entry. Cable seals feature a new heatshrink sleeve and hot melt adhesive system that is installed with a hot-air gun.
Common materials, accessories and practices are used throughout the product line to simplify training, reduce inventory and enhance productivity. FOSC 400 fiber optic splice closures are available in three sizes: the FOSC 400 A, FOSC 400 B and FOSC 400 D.
All sizes are designed for use with any cable construction (loose buffer tube, central core tube, loose fiber, ribbon), in any environment (aerial, pedestal, buried, handhole, manhole) and for numerous splice applications (expressed, tap-off, branch and repair).
commscope.com3
FOSC 400 A4/A8 closureThe FOSC 400 A4 closure is the smallest in the FOSC 400 series. It is intended for low fiber-count cable splices and “tap-off” splices. Tap-off splices are those where most of the fibers in a cable are ‘expressed’ uncut through the closure.
Only a few fibers are cut and re-spliced to feed a building or Optical Network Unit (ONU). The FOSC 400 A4/A8 closure comes ready to store expressed loose buffer tubes. An optical slack storage basket is available for expressed stranded fiber and ribbon fiber. As with all FOSC 400 closures, the slack storage and splice capacity of the FOSC 400 A4/A8 depends on factors such as cable construction, splice type and slack fiber lengths. Refer to the Closure Capabilities chart for more details.
FOSC 400 B2 and FOSC 400 B4 closuresFOSC 400 B2 and FOSC 400 B4 closures are identical except for their end cable port configuration. In addition to a large oval port for the main distribution cable, the B2 closure has two large round ports for branch cable splices while the B4 closure has four small round ports for multiple drop applications. The FOSC 400 closure cable sealing system provides a great deal of flexibility. For example, with the use of branch-off clips four small cables can be terminated in two round ports of a B2 closure.
FOSC 400 D5 closureThe FOSC 400 D5 closure is the largest in the FOSC 400 series. It can terminate seven cables (or up to twelve cables with the use of branch off clips), through one oval port and five large round ports.
The splice capacity is 288 single mechanical, 768 single fusion or 1152 mass-fusion (12) fibers. Ribbon fiber can be stored directly on the trays or in the versatile slack basket that also holds expressed or uncut loose buffer tubes.
commscope.com4
Op�onal ground feed-through lug
4 round ports for cables 5 to 19 mm (0.20" to 0.75")
Oval port for 2 cables10 to 25 mm (0.4" to 1.0")
8 round ports for cables5 to 10 mm (0.2" to 0.4")
A8 A4
420 mm (16.5")(Cable seals add 100 mm (4") to length)
Closure comes with buffer tube storagecapability. Op�onal basket available forstoring slack stranded fiber and ribbon
Termina�ons for cable strengthmembers and bond wires
Closure will hold 2 fiberorganizer trays
Mechanicaldome-to-base seal
150 mm 180 mm(6") (7")
Op�onal flash-test valve
2 round ports for cables 5 to 32 mm(0.20" to 1.25")
Oval ports for cables10 to 25 mm (0.4" to 1.0")
B2 B4
Op�onal ground feed-through lugs
4 round ports for cables5 to 19 mm (0.20" to 0.75")
Op�onal flash-test valve
540 mm (21")(Cable seals add 100 mm (4") to length)
150 mm 180 mm(6.3") (7")
Op�onal baskets available for storing slackmembers and bond wires
Termina�ons for cable strengthmembers and bond wires
Closure will hold 4 fiberorganizer trays
Mechanicaldome-to-base seal
5 round ports for cables5 to 32 mm (0.20" to 1.25")
Op�onal ground feed-through lugs
Oval port for 2 cables10 to 25 mm (0.4" to 1.0")
D5 Flash-test valve
710 mm (28")(Cable seals add 100 mm (4") to length)
240 mm 260 mm(9.5") (10.2")
Op�onal basket to store slack loosebuffer tubes or ribbon. (Store slack strandedfiber on bo�om organizer tray)
Termina�ons for cable strengthmembers and bond wires
Closure will hold 8 trays(6 with op�onal basket)
Mechanicaldome-to-base seal
commscope.com5
B fiber organizer trayD fiber organizer tray Special B fiber organizer tray with splice modules
Hinge
ClosureSpliced fiber storage capacity Slack storage capacity
Single fusion Single mechanical Mass fusion Buffer tubes Stranded fibers 12 fiber ribbons
FOSC 400 A4 748 2241 24 8 96 6
FOSC 400 A8 96 48 288 6 96 24
FOSC 400 B2, B4 96/1442 48/602 288 6 96 24
FOSC 400 D5 768 288 1152 18 96 72
1 Varies with splice type. Capacity is 24 for most commonly used mechanical splices. 2 With special tray tower for 6 trays.
Fiber ManagementThe stacked fiber splice and organizer trays in FOSC 400A4, B2 and B4 closures can accommodate two different splice holders. The universal splice holder is suitable for fusion and most common mechanical splices. Up to eight splices can be stored in each S08 A-tray and twelve splices in the S12 B-tray.
The high capacity splice holder doubles the tray capacity using 45 mm fusion splice protectors (SMOUV-1120-02): sixteen splices in the S16 A-tray and twenty-four splices in the S24 A- and S24 B-tray.
The fiber splice and organizer trays in FOSC 400D5 contain interchangeable splice modules. Six splice modules are mounted in each D-tray.
The standard SM6 splice module or ‘6-pack’ will hold six single-fusion, mechanical, or mass fusion splices. Splice modules are also available for mass mechanical splices and high density single-fusion splices. These splice modules also fit in special organizer B-trays. Up to two splice modules can be mounted in one special B-tray.
These special B-trays can be easily adapted in the future for splitters, connectors, etc., by inserting new splice modules.
All FOSC 400 closures have organizer trays that are hinged at one end. Any tray can be accessed without disturbing the others, kinking buffer tubes, or introducing losses. In addition, any fiber can be spliced to any other fiber with the intertray jumper system. Engineering flexibility and error-free access are important in today’s evolving, high speed fiber networks.
commscope.comVisit our website or contact your local CommScope representative for more information.
© 2017 CommScope, Inc. All rights reserved.
All trademarks identified by ® or ™ are registered trademarks or trademarks, respectively, of CommScope, Inc. This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to CommScope products or services. CommScope is committed to the highest standards of business integrity and environmental sustainability, with a number of CommScope’s facilities across the globe certified in accordance with international standards, including ISO 9001, TL 9000, and ISO 14001. Further information regarding CommScope’s commitment can be found at www.commscope.com/About-Us/Corporate-Responsibility-and-Sustainability.
BR-110901-EU (02/17)
Everyone communicates. It’s the essence of the human experience. How we communicate is evolving. Technology is reshaping the way we live, learn and thrive. The epicenter of this transformation is the network—our passion. Our experts are rethinking the purpose, role and usage of networks to help our customers increase bandwidth, expand capacity, enhance efficiency, speed deployment and simplify migration. From remote cell sites to massive sports arenas, from busy airports to state-of-the-art data centers—we provide the essential expertise and vital infrastructure your business needs to succeed. The world’s most advanced networks rely on CommScope connectivity.