Fan Coil Units - HEINEN & HOPMAN 2020 © 1Fan Coil Units - HEINEN & HOPMAN 2020 ©1
FAN COIL UNITSFAN COIL UNITSProducts
Ventilation Air Conditioning RefrigerationHeating
PROVIDED BYHEINEN & HOPMAN
Inside22ºC
OUTSIDE35°C45°C
HUMIDITY90%40%
Fan Coil Units - HEINEN & HOPMAN 2020 © 1Fan Coil Units - HEINEN & HOPMAN 2020 ©1
COMPANY INTRODUCTION
Heinen & Hopman is a reliable partner in the global maritime sector, offering top quality products and service in the field of climate control (HVAC & Refrigeration). The no-nonsense and entrepreneurial character of the founders who established the company in 1965 is still one of the main cornerstones of Heinen & Hopman. We support our clients using our knowledge and experience by realising the best possible climate control solutions; either fully customised or with varying degrees of standardisation. Like our clients, we are continuously active on a global scale to ensure that we can always be of service. We are also constantly searching for sustainable innovations as we aim for the best and very latest solutions in collaboration with our clients. Heinen & Hopman is critically aware that a company’s greatest asset is its employees – it is they who represent the added value of our business. Our goal is to continue to expand in the global market for maritime climate control solutions in a future-proof way.
In short, you can rely on Heinen & Hopman to deploy the know-how and expertise required to solve any heating, ventilation, air conditioning and refrigeration issue onboard ships. We see complexity as a challenge, no matter where your vessel may be.
OPERATING GLOBALLY
Global networking is crucial in every line of business and the shipping industry is certainly no exception. Being able to offer the highest quality of service and products to our clients at all times and in all places is of enormous importance to us. This is why Heinen & Hopman aims to keep expanding our network and know-how and ensure we are exactly where our clients need us to be.
Americas
Europe
Asia3
Countries11Offices
3Factories
220Employees
11Countries
22Offices
4Factories
1200Employees
7Countries
10Offices
7Factories
380Employees
Fan Coil Units - HEINEN & HOPMAN 2020 © 2Fan Coil Units - HEINEN & HOPMAN 2020 ©2
FAN COIL UNITS
Heinen & Hopman fan coils units are designed to operate in the marine industry where high standards are required.
Types• SIGMA: Fan coil unit with casing. Capacity:
0,6 kW - 11.72 kW• PRISMA: Fan coil unit with casing.
Capacity: 0.6 kW - 3.90 kW• LOW BODY: Fan coil unit with or without
casing, designed for installation in small niches. Capacity: 0.6 kW - 3.90 kW.
• CONCEALED: Fan coil unit without casing. Capacity: 0.6 kW - 11.72 kW.
• ATL: Fan coil unit designed for Yacht sector.• Custom made: Fan coil unit designed on
customer request.
Green technologyEnergy-saving technology is applied to our fan coil units to obtain extremely low electrical absorption and a continuous modulation of the air flow, related to the energy needs in the room.
Energy-saving technology is composed by a brushless motor combined with an inverter, managed by specific regulators.
Compared to units with asynchronous 3-speed motors, the fan coil units with brushless motors will reduce the power consumption up to 70%.
Fan Coil Units- HEINEN & HOPMAN 2020©2
EST
W80%
70%
60%
50%
40%
30%
20%
10%
0%
W80%
70%
60%
50%
40%
30%
20%
10%
0%
EST (Energy Saving Technology) is applied to the EURAPO fan coil units and cassette units. It permits to
obtain extremely low electrical absorption and a continuous modulation of the air flow, constantly related to the
concrete need of energy in the room.
EST technology is composed by a brushless motor combined to a dedicated electronic device (inverter),
managed by specific regulators developed by EURAPO.
In comparison to the traditional units equipped with asynchronous three-speed-motors, the fan coil and cassette
units with brushless motors can obtain a considerable energy saving, by reducing the power consumption up to 70%.
Thanks to the step-less modulation of the fan speeds it is possible to accurately regulate the air volume in a very
precise way, in strict relation to the real need of air conditioning in the room. Oscillations in the temperature and
relative humidity are reduced at lowest level: a guarantee for the highest comfort in the room.
The possibility to reach very low air volumes makes the units extremely quiet at the lowest motor revolutions.
EST technology is designed in particular for offices, hospitals, nursing homes and hotels.
It is available for the EURAPO range of fan coil units, cassette units and ducted units.
The EST technology consists of a brushless motor combined to a dedicated electronic device (inverter),
managed by specific regulators. The controller uses a modulating signal with 0-10Vdc tension in order to regulate
the fan speed.
The brushless electric motor is composed by a rotor having permanent magnets, whose magnetic fields
interact with the ones produced by the stator winding.
The transfer of current is no longer by mechanical commutation (sliding contacts) but by an electronic commutation
system: an electronic controller (inverter) powers the motor’s stator and generates rotating magnetic fields, that
determine the rotor’s speed.
speed 6
Energy saving with EST fancoil
speed 5 speed 4 speed 3 speed 2 speed 1
m3/h m3/h
speed 6
Asynchronous fan coil absorption (W)
EST fancoil absorption (W)
speed 5
speed 4
speed 3
speed 2
speed 1
EST
Fan Coil Units - HEINEN & HOPMAN 2020 © 3Fan Coil Units - HEINEN & HOPMAN 2020 ©3
SIGMA FAN COIL UNITS • Fan coil unit with casing• Heating and cooling applications• Capacity: 0.6 kW - 11.7 kW
SIGMA fan coils units can be used in all environments and for different applications. The fan coil units are highly reliable in performance.The fan coil units can be installed on the floor or on the ceiling in both configurations.
CasingThe casing, with upper air outlet, is made of sheet steel and painted with oven-dried epoxy powders, available in all RAL colors.The access doors and grilles are made of white heat-resistant ABS and can be turned into all four directions.The filter is fully retractable and easily accessible.
Models
Dimensions and weightModel: SV - SV/AF - SH - SH/AF
B
A C
Dimensions (mm) and weight for SV - SV/AF - SH - SH/AF
110 112 114 216 218 220 222 224 226 228 A 648 773 898 1023 1148 1273 1273 1523 1523 1773 B 538 538 538 538 538 614 614 614 614 614 SV - SH C 224 224 224 224 224 254 254 254 254 254 Kg 18 20 23 28 31 41 44 52 52 58 SV/AF - SH/AF C 233 233 233 233 233 263 263 263 263 263 Kg 19 21 24 30 32 43 46 54 54 61 HYDRAULIC CONNECTION 1/2” G F
Dimensions (mm) and weight for PV - PV/AF - PH - PH/AF
110 112 114 216 218 A 648 773 898 1023 1148 B 560 560 560 560 560 PV - PH C 226 226 226 226 226 Kg 17 20 23 27 31 PV/AF - PH/AF C 235 235 235 235 235 Kg 18 21 24 28 32 HYDRAULIC CONNECTION 1/2” G F
SIGMA PRISMA
FAN
CO
IL U
NIT
mod. SH mod. PHmod. SH/AF mod. PH/AF
mod. SV
mod. SV mod. PV
mod. SH/AF mod. PH/AF
mod. PVmod. SV/AF mod. PV/AF
110 112 114 216 218 220 222 224 226 228
A 648 773 898 1023 1148 1273 1273 1523 1523 1773
B 538 538 538 538 538 614 614 614 614 614
SV-- --SHC 224 224 224 224 224 254 254 254 254 254
kg 18 20 23 28 31 41 44 52 52 58
SV/AF-- --SH/AFC 233 233 233 233 233 263 263 263 263 263
kg 19 21 24 30 32 43 46 54 54 61
Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.
Don’t hesitate to contact us for more information about our service options. We are eager to explain the possibilities for your vessel or structure.
Scan the QR-code or visit heinenhopman.com
Fan Coil Units - HEINEN & HOPMAN 2020 © 4Fan Coil Units - HEINEN & HOPMAN 2020 ©4
PRISMA FAN COIL UNITS • Fan coil unit with casing• Heating and cooling applications (PV and PV/AF only)• Capacity: 0.6 kW - 3.9 kW
The PRISMA fan coil units have an original shape. The casing is a piece of furniture, made of painted metal sheet with side flaps and grilles made of ABS.The fan coil units can be installed on the floor or on the cei-ling. The air intake can be located on the bottom or on the front in both configurations.
CasingThe casing, with upper air outlet, is made of sheet steel and painted with oven-dried epoxy powders, available in all RAL colors.The access doors and grilles are made of white heat-resistant ABS and can be turned into all four directions. The filter is fully retractable and easily accessible.
Models
Dimensions and weightModel: PV - PV/AF - PH - PH/AF
B
A C
Dimensions (mm) and weight for SV - SV/AF - SH - SH/AF
110 112 114 216 218 220 222 224 226 228 A 648 773 898 1023 1148 1273 1273 1523 1523 1773 B 538 538 538 538 538 614 614 614 614 614 SV - SH C 224 224 224 224 224 254 254 254 254 254 Kg 18 20 23 28 31 41 44 52 52 58 SV/AF - SH/AF C 233 233 233 233 233 263 263 263 263 263 Kg 19 21 24 30 32 43 46 54 54 61 HYDRAULIC CONNECTION 1/2” G F
Dimensions (mm) and weight for PV - PV/AF - PH - PH/AF
110 112 114 216 218 A 648 773 898 1023 1148 B 560 560 560 560 560 PV - PH C 226 226 226 226 226 Kg 17 20 23 27 31 PV/AF - PH/AF C 235 235 235 235 235 Kg 18 21 24 28 32 HYDRAULIC CONNECTION 1/2” G F
SIGMA PRISMA
FAN
CO
IL U
NIT
mod. SH mod. PHmod. SH/AF mod. PH/AF
mod. SV
mod. SV mod. PV
mod. SH/AF mod. PH/AF
mod. PVmod. SV/AF mod. PV/AF
110 112 114 216 218
A 648 773 898 1023 1148
B 560 560 560 560 560
PV-- --PHC 226 226 226 226 226
kg 17 20 23 27 31
PV/AF-- --PH/AFC 235 235 235 235 235
kg 18 21 24 28 32
Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.
Don’t hesitate to contact us for more information about our service options. We are eager to explain the possibilities for your vessel or structure.
Scan the QR-code or visit heinenhopman.com
Fan Coil Units - HEINEN & HOPMAN 2020 © 5Fan Coil Units - HEINEN & HOPMAN 2020 ©5
LOW BODY FAN COIL UNITS
• Fan coil unit with casing• Heating and cooling applications• Capacity: 0.48 kW - 3.7 kW
The LOW BODY fan coils units have a reduced height (427 mm) and can be installed in small niches.The low-body units have an upper air outlet and a front air intake. The fan coil units can be installed either on the floor or on the wall, or concealed.
CasingThe inner frame is made of galvanized steel. The casing is made of sheet steel and painted with oven-dried epoxy powders, available in all RAL colors.The access doors and grilles are made of white heat-resistant ABS and can be turned into all four directions.
Models
Dimensions and weightModel: CVRModel: SVR
Dimensions (mm) and weight for CV - CV/AF - CH - CH/AF
110 112 114 216 218 220 222 224 226 228 CV - CH A 555 680 805 930 1055 1180 1180 1430 1430 1680 CV/AF -CH/AF A 574 699 824 949 1074 1199 1199 1449 1449 1699 CV - CV/AF - CH - CH/AF B 505 505 505 505 505 581 581 581 581 581 C 215 215 215 215 215 245 245 245 245 245 Kg 10 13 16 19 22 29 31 38 38 42HYDRAULIC CONNECTION 1/2” G F
CONCEALED
Dimensions (mm) and weight CVR
110 112 114 216 218 A 555 680 805 930 1055 B 395 395 395 395 395 C 230 230 230 230 230Kg 9 11 14 16 19HYDRAULIC CONNECTION 1/2” G F
Dimensions (mm) and weight SVR
110 112 114 216 218 A 648 773 898 1023 1148 B 430 430 430 430 430 C 254 254 254 254 254Kg 15 17 22 23 26HYDRAULIC CONNECTION 1/2” G F
LOW BODY
mod. CH mod. CH/AFmod. SVR
mod. CH
mod. CV/AFmod. CVR
mod. SVR
mod. CV mod. CV/AF
mod. CVR
110 112 114 216 218
A 555 680 805 930 1055
B 395 395 395 395 395
C 230 230 230 230 230
kg 9 11 14 16 19
110 112 114 216 218
A 648 773 898 1023 1148
B 430 430 430 430 430
C 254 254 254 254 254
kg 15 17 22 23 26
Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.
Don’t hesitate to contact us for more information about our service options. We are eager to explain the possibilities for your vessel or structure.
Scan the QR-code or visit heinenhopman.com
Fan Coil Units - HEINEN & HOPMAN 2020 © 6Fan Coil Units - HEINEN & HOPMAN 2020 ©6
CONCEALED FAN COIL UNITS
• Fan coil unit without casing• Heating and cooling applications• Capacity: 0.6 kW - 11.72 kW
The CONCEALED fan coils units can be used for ductwork installations. The fan coil units are highly reliable in perfor-mance, silent and can be equipped with a wide range of accessories.The fan coil units can be installed vertically, on the wall (with bottom air intake) or on the floor (with front air intake), and horizontally, on the ceiling (with bottom or rear air intake).The fan coil units are the ideal solution for the needs of small spaces and limited sizes that influence the choice of furniture in homes or offices.
CasingAvailable in ten sizes, the concealed model has an electric box with terminal board and auxiliary drain pan. The frame is made of galvanized steel. The inner sides are completely lined with an insulating self-extinguishing material.
Models
Dimensions and weight Model: CV - CV/AF - CH - CH/AF
Dimensions (mm) and weight for CV - CV/AF - CH - CH/AF
110 112 114 216 218 220 222 224 226 228 CV - CH A 555 680 805 930 1055 1180 1180 1430 1430 1680 CV/AF -CH/AF A 574 699 824 949 1074 1199 1199 1449 1449 1699 CV - CV/AF - CH - CH/AF B 505 505 505 505 505 581 581 581 581 581 C 215 215 215 215 215 245 245 245 245 245 Kg 10 13 16 19 22 29 31 38 38 42HYDRAULIC CONNECTION 1/2” G F
CONCEALED
Dimensions (mm) and weight CVR
110 112 114 216 218 A 555 680 805 930 1055 B 395 395 395 395 395 C 230 230 230 230 230Kg 9 11 14 16 19HYDRAULIC CONNECTION 1/2” G F
Dimensions (mm) and weight SVR
110 112 114 216 218 A 648 773 898 1023 1148 B 430 430 430 430 430 C 254 254 254 254 254Kg 15 17 22 23 26HYDRAULIC CONNECTION 1/2” G F
LOW BODY
mod. CH mod. CH/AFmod. SVR
mod. CH
mod. CV/AFmod. CVR
mod. SVR
mod. CV mod. CV/AF
mod. CVR
110 112 114 216 218 220 222 224 226 228
CV-- --CH
A 555 680 805 930 1055 1180 1180 1430 1430 1680
CV / AF-- --CH / AFA 574 699 824 949 1074 1199 1199 1449 1449 1699
CV-- --CV / AF --CH-------- --CH / AFB 505 505 505 505 505 581 581 581 581 581
C 215 215 215 215 215 245 245 245 245 245
kg 10 13 16 19 22 29 31 38 38 42
Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.
Don’t hesitate to contact us for more information about our service options. We are eager to explain the possibilities for your vessel or structure.
Scan the QR-code or visit heinenhopman.com
Fan Coil Units - HEINEN & HOPMAN 2020 © 7Fan Coil Units - HEINEN & HOPMAN 2020 ©7
TECHNICAL DATA (3 rows - Energy saving technology)
Cooling
Air
tem
pera
ture
: 2
7 0
C d
.b.,
19
0C
w
.b.
Wat
er t
empe
ratu
re:
7 /
12
0C
Total cooling capacity (kW)
Sensible cooling capacity (kW)
Water flow (l/h)
Pressure drop (kPa)
Heatin
g
Air
tem
pera
ture
: 2
0 0
C
Wat
er in
let
tem
pera
-tu
re:
50
0C
Heating capacity (kW)
Water flow (l/h)
Pressure drop (kW)
Heatin
g
Air
tem
pera
ture
: 2
0 0
C
Wat
er in
let
tem
pera
ture
: 7
0 /
60
0C
Heating capacity (kW)
Water flow (l/h)
Pressure drop (kPa)
Further d
ata
Air volume (m3/h)
Sound power level (dB[A])
Sound pressure level (dB[A]) (1)
Power input (W) (2)
Absorbed current (A) (2)
Water content (l)
112 114 216 220 222 224 228
9V 1.91 2.90 3.60 5.01 6.06 8.11 10.50
6V 1.35 2.15 2.55 3.75 4.50 5.71 7.30
3V 0.63 1.02 1.18 1.98 2.03 3.21 4.30
9V 1.57 2.39 2.84 4.04 4.97 6.49 7.90
6V 1.08 1.70 1.92 2.91 3.55 4.57 5.40
3V 0.49 0.49 0.91 1.50 1.61 2.45 3.00
9V 328 498 618 860 1120 1392 1802
6V 232 369 438 643 793 980 1253
3V 108 175 202 340 408 551 738
9V 8.90 8.40 13.20 28.30 17.10 24.10 42.30
6V 4.80 4.70 7.30 17.40 8.40 12.90 25.00
3V 1.40 1.60 1.80 5.60 7.70 4.30 10.20
9V 2.64 4.08 5.16 6.35 8.01 9.92 10.80
6V 1.90 2.71 3.77 4.72 5.49 6.71 8.20
3V 0.98 1.27 2.07 2.42 2.76 4.22 5.30
Value as Cooling accordingly to the Eurovent Standards and UNI ENV 1397 Norm
9V 3.70 7.30 12.90 23.30 26.00 22.80 39.80
6V 2.60 3.50 7.10 17.60 7.20 10.70 23.00
3V 2.10 1.50 1.80 4.40 6.30 3.50 8.70
9V 4.56 7.04 8.85 10.76 13.84 16.73 17.84
6V 3.27 4.61 6.52 7.97 10.13 11.24 13.68
3V 1.69 2.17 3.57 4.06 5.24 7.11 8.91
9V 400 619 777 945 1216 1469 1566
6V 287 405 572 700 890 987 1202
3V 149 190 314 357 460 625 783
9V 5.30 10.70 19.20 26.80 33.00 24.30 29.70
6V 3.80 4.00 11.30 19.80 8.60 10.50 20.50
3V 3.70 1.70 3.80 4.60 7.60 4.20 9.30
9V 432 583 791 1010 1305 1828 2050
6V 286 379 523 675 857 1200 1330
3V 128 172 248 323 403 582 620
9V 56 57 61 57 63 67 70
6V 45 49 50 46 57 57 61
3V 31 30 34 30 37 45 41
9V 46 48 51 48 53 58 60
6V 36 40 41 37 48 48 52
3V 30* 30* 30* 30* 30* 36 32
9V 31 48 52 50 104 170 230
9V 0.28 0.42 0.46 0.44 0.88 1.37 1.70
V 0.79 1.05 1.31 2.20 2.20 2.84 3.47
NOTE:Performances of LOW BODY models are about 11% lower than the standard ones in heating operation and 12,3% lower in cooling operation. For greater accuracy please contact Heinen Hopman.
To obtain capacities for 2 or 4 row coils, or for conditions different from standard ones, please contact our staff.
The printed data could be modified without any notice.(1) Sound pressure level in a 100 m3 room, at a 1.5m distance and with a reverberating time of 0.3 s.(2) Electrical supply: 230-1-50 [V-ph-Hz].* Minimum value measurable in laboratory, indicated by Eurovent.
Fan Coil Units - HEINEN & HOPMAN 2020 © 8Fan Coil Units - HEINEN & HOPMAN 2020 ©8
TECHNICAL DATA (3 rows - asynchronous)C
ooling
Air
tem
pera
ture
: 2
7 0
C d
.b.,
19
0C
w
.b.
Wat
er t
empe
ratu
re:
7 /
12
0C
Total cooling capacity (kW)
Sensible cooling capacity (kW)
Water flow (l/h)
Pressure drop (kPa)
Heatin
g
Air
tem
pera
ture
: 2
0 0
C
Wat
er in
let
tem
pera
-tu
re:
50
0C
Heating capacity (kW)
Water flow (l/h)
Pressure drop (kW)
Heatin
g
Air
tem
pera
ture
: 2
0 0
C
Wat
er in
let
tem
pera
ture
: 7
0 /
60
0C
Heating capacity (kW)
Water flow (l/h)
Pressure drop (kPa)
Further d
ata
Air volume (m3/h)
Sound power level (dB[A])
Sound pressure level (dB[A]) (1)
Power input (W) (2)
Absorbed current (A) (2)
Water content (l)
110 112 114 216 218 220 222 224 226 228
MAX 1.16 1.64 2.20 3.36 3.58 4.53 5.19 6.57 7.41 9.50
MED 0.99 1.35 1.92 2.72 3.05 3.75 4.48 5.87 6.81 7.75
MIN 0.79 1.10 1.60 2.24 2.50 2.99 3.91 4.70 5.61 6.18
MAX 0.98 1.30 1.96 2.52 3.14 3.62 4.54 5.20 5.86 7.02
MED 0.82 1.03 1.68 2.00 2.57 2.91 3.83 4.56 5.32 5.53
MIN 0.64 0.82 1.36 1.60 2.04 2.25 3.27 3.53 4.26 4.27
MAX 199 281 414 577 614 777 891 1127 1271 1630
MED 170 232 360 467 524 643 769 1007 1168 1330
MIN 136 189 300 366 429 513 671 806 963 1060
MAX 3.40 7.10 5.80 14.80 13.60 24.10 28.40 18.80 21.00 16.90
MED 2.80 5.00 4.60 12.50 9.80 17.40 21.80 15.50 18.10 25.80
MIN 2.00 3.40 3.30 8.50 6.70 11.60 17.20 10.50 12.80 17.30
MAX 1.57 2.16 3.05 4.11 4.95 5.74 7.19 7.83 9.33 10.70
MED 1.28 1.73 2.43 3.44 4.16 4.65 6.08 6.94 8.51 8.60
MIN 1.00 1.35 2.00 2.75 3.35 3.61 5.25 5.45 6.86 6.74
Value as Cooling accordingly to the Eurovent Standards and UNI ENV 1397 Norm
MAX 2.70 6.10 4.80 11.90 12.50 20.00 23.50 15.50 20.50 34.60
MED 2.30 4.70 3.70 8.50 9.10 14.30 18.00 12.70 17.60 24.20
MIN 1.70 3.10 2.80 5.70 6.30 9.50 14.20 8.70 12.40 16.30
MAX 2.74 3.70 5.20 6.93 8.48 9.64 12.25 13.19 15.77 17.83
MED 2.23 2.94 4.09 5.82 7.12 7.85 10.32 11.66 14.38 14.35
MIN 1.74 2.28 3.37 4.65 5.71 6.04 8.93 9.15 11.58 11.22
MAX 241 325 456 608 745 847 1076 1159 1385 1566
MED 196 258 359 511 625 689 907 1024 1263 1260
MIN 153 201 396 408 502 531 784 804 1017 985
MAX 2.80 7.80 5.60 12.70 17.30 22.60 32.20 15.70 23.10 30.90
MED 2.90 5.60 3.60 9.80 12.20 15.60 23.50 12.60 19.60 21.10
MIN 2.10 3.40 2.60 6.20 8.10 9.70 18.20 8.30 13.20 13.70
MAX 245 320 436 580 709 856 1074 1254 1481 1687
MED 191 249 358 456 592 676 920 1113 1352 1151
MIN 144 194 289 338 474 527 739 797 999 838
MAX 48 50 54 53 55 54 60 60 63 67
MED 42 45 49 47 50 48 56 55 60 60
MIN 36 38 42 40 43 40 50 47 53 55
MAX 39 41 44 44 46 44 50 49 53 57
MED 33 36 39 38 42 38 45 47 54 50
MIN 30 30 33 31 34 31 40 40 44 45
MAX 46 45 57 61 86 90 117 140 162 178
MAX 0.23 0.23 0.26 0.29 0.33 0.38 0.52 0.65 0.65 1.04
0.53 0.79 1.05 1.31 1.57 2.20 2.20 2.84 2.84 3.47
NOTE:Performances of LOW BODY models are about 11% lower than the standard ones in heating operation and 12,3% lower in cooling operation. For greater accuracy please contact Heinen Hopman.
To obtain capacities for 2 or 4 row coils, or for conditions different from standard ones, please contact our staff.
The printed data could be modified without any notice.(1) Sound pressure level in a 100 m3 room, at a 1.5m distance and with a reverberating time of 0.3 s.(2) Electrical supply: 230-1-50 [V-ph-Hz].* Minimum value measurable in laboratory, indicated by Eurovent.
Fan Coil Units - HEINEN & HOPMAN 2020 © 9Fan Coil Units - HEINEN & HOPMAN 2020 ©9
ATL-DC LOW PROFILE FAN COIL UNITS
The ATL-DC fan coil units are used in areas with reduced heights and an excellent choice for the yacht sector. The ATL-DC units represents an improved design approach to low profile, allow easier maintenance access and reduced dimensions overall.The drain pan has an anti-slosh, anti-fungal foam lining and extends to under the valve motor and plumbing. The water connections are insulated against secondary condensation. The valve can be installed to the left or to the right.
Advantages• Blowers are extremely silent yet powerful enough to overcome high-static-pressure duct;• Improved design for easy servicing, smaller dimensions;• Top panel is removable for easier access;• Dual blowers are installed horizontally for exceptionally low profile;• Suspension from above or support from beneath (hardware included);• Internal components are insulated against secondary condensation;• Vibration isolation mounts reduce noise and vibration;• Bypass valve has removable power head for easy servicing;• Optional flow control automatically balances circulated water throughout
the system.• Optional electric heater
Dimensions
Model ATL6DC ATL9DC ATL12DC ATL18DC ATL24DC ATL36DC
Capacity (kW) 1.76 2.64 3.52 5.27 7.03 10.54
V @ 50/60Hz / 1-Phase 230 230 230 230 230 230
Amps (FLA) Cool 1.4 1.4 2.8 2.8 3.9 7.8
Amps (FLA) Blower 1.4 1.4 2.8 2.8 1.5 3
Optional heater (kW) (1) 1 1 1.5 1.5 1.5 3
Heater Amps (A) 5.7 5.7 11.5 11.5 8 16
Max. Circuit breaker (A) 5 5 5 5 5 30
Min. Circuit breaker (A) 2 2 4 4 5 23
Water flow (GPM / I / min) 1.5 / 5.7 2.25 / 8.6 3 / 11.4 4.5 / 17.1 6 / 22.8 9 / 34.1
Air flow (CFM / m3/h) (2) 200 / 340 233 / 396 350 / 595 467 / 793 670 / 1139 1000 / 1700
External static pressure (H20 / Pa) 1.75 / 435 0.6 / 149 1.75 / 435 0.6 / 149 0.3 / 75 0.3 / 75
Height deck mount (in / mm) (3) 8 / 204 8 / 204 8 / 204 8 / 204 10 / 254 10 / 254
Height suspension mount (in / mm) (3) 8.2 / 209 8.2 / 209 8.2 / 209 8.2 / 209 10.1 / 257 10.1 / 257
Max. Width (in / mm) (3) 19.6 / 498 19.6 / 498 31.5 / 801 31.5 / 801 43.8 / 1113 61.8 / 1570
Depth without heat (in / mm) (3) 19.7 / 501 19.7 / 501 17.9 / 455 17.9 / 455 20.5 / 521 20.5 / 521
Depth with heat (in / mm) (3) 25.4 / 646 25.4 / 646 23.6 / 600 23.6 / 600 26.2 / 666 26.2 / 666
Drain connection type tube stubs FPT tube stubs tube stubs tube stubs tube stubs
Drain connection size ½” ½” ½” ½” ½” ½”
Chilled water connection type FPT FPT FPT FPT FPT FPT
Chilled water connection size ½” ½” ½” ½” ½” ½”
Quantity duct connections (in/mm) 1 1 2 2 1 2
Minimum supply duct size (in/mm) (4) 4 / 102 6 / 153 6 / 153 7 / 178 9 / 229 10 / 254
Minimum supply air grill size (in2 / cm2) 35 / 226 49 / 316 35 / 226 49 / 316 147 / 949 168 / 1084
Total return air inlet (in2 / cm2) 70 / 452 98 / 633 130 / 839 200 / 1291 240 / 1549 360 / 2323
Pan style Sloped Sloped Sloped Sloped Sloped Sloped
1 1.5kW is recommended for the ATL24 because it has one blower. 2kW is maximum.2 Air flow data is for units without electric heat. Electric heat reduces air flow by amount to be determined.3 All dimensions ±0.3 inch (8mm).4 ATL 12, ATL18 and ATL36 models have dual blowers and therefore two supply duct rings.
Fan Coil Units - HEINEN & HOPMAN 2020 © 10Fan Coil Units - HEINEN & HOPMAN 2020 ©10
ATL-HV LOW PROFILE FAN COIL UNITS
The ATL-HV fan coil units are ideal for height-restrictive installations; high velocity blowers. The ATL-HV units represents an improved design approach to low profile, allow easier maintenance access and reduced dimensions overall.The drain pan has an anti-slosh, anti-fungal foam lining and extends to under the valve motor and plumbing. The water connections are insulated against secondary condensation. The valve can be installed to the left or to the right.
Advantages• Blowers are extremely quiet yet powerful enough to overcome high-static-pressure duct;• Suspension from above or support from beneath (hardware included);• Internal components are insulated against secondary condensation;• Vibration isolation mounts reduce noise and vibration;• Bypass valve has removable power head for easy servicing;• Automatically flow control helps balance chilled water distrubution throughout the boat.• Optional electric heater
Dimensions
Model ATL6 HV ATL9 HV ATL12HV ATL18HV ATL24HV
Capacity (kW) 1.76 2.64 3.52 5.27 7.03
V @ 50/60Hz / 1-Phase 230 230 115 230 230 115 230
Amps (FLA) Cool 0.9 0.6 3.12 1.8 1.8 2.3 1.15
Amps (FLA) Blower 0.7 0.5 3.2 1.4 1 3.4 1.3
Optional heater (kW) (1) 1 1 2 2 1.5
Heater Amps (A) 5 4.8 20.6 10.1 9.7 16.4 7.8
Max. Circuit breaker (A) 5 5 5 5 5
Min. Circuit breaker (A) 2 1 4 3 3 3 2
Water flow (GPM / I / min) 1.5 / 5.7 2.25 / 8.6 3 / 11.4 4.5 / 17.1 6 / 22.8
Air flow (CFM / m3/h) (2) 200 / 340 233 / 396 350 / 595 467 / 793 730 / 1241
External static pressure (H20 / Pa) 0.3 / 75 0.3 / 75 0.3 / 75 0.3 / 75 0.3 / 75
Height deck mount (in / mm) (3) 8 / 204 8 / 204 8.1 / 206 8.1 / 206 10 / 254
Height suspension mount (in / mm) (3) 8.1 / 206 8.1 / 206 8.1 / 206 8.1 / 206 10.1 / 257
Max. Width (in / mm) (3) 19.6 / 498 19.6 / 498 31.6 / 803 31.6 / 803 42.9 / 1090
Depth without heat (in / mm) (3) 18 / 458 19.7 / 501 17.9 / 455 25.5 / 648 22 / 559
Depth with heat (in / mm) (3) 23.7 / 602 25.4 / 646 23.6 / 600 19.8 / 503 27.7 / 704
Drain connection type tube stubs FPT tube stubs tube stubs tube stubs
Drain connection size ½” ½” ½” ½” ½”
Chilled water connection type FPT FPT FPT FPT FPT
Chilled water connection size ½” ½” ½” ½” ½”
Quantity duct connections (in/mm) 1 1 2 2 1
Minimum supply duct size (in/mm) (4) 4 / 102 6 / 153 6 / 153 7 / 178 9 / 229
Minimum supply air grill size (in2 / cm2) 35 / 226 49 / 316 35 / 226 49 / 316 147 / 949
Total return air inlet (in2 / cm2) 70 / 452 98 / 633 130 / 839 200 / 1291 240 / 1549
Pan style Sloped Sloped Sloped Sloped Sloped
1 1.5kW is recommended for the ATL24 because it has one blower. 2kW is maximum.2 Air flow data is for units without electric heat. 3 All dimensions ±0.3 inch (8mm).4 ATL 12, ATL18 and ATL36 models have dual blowers and therefore two supply duct rings.
Fan Coil Units - HEINEN & HOPMAN 2020 © 11Fan Coil Units - HEINEN & HOPMAN 2020 ©11
AU-DC FAN COIL UNITS
The AU-DC fan coil units are designed for easy installation and high performance. AU-DC models feature ultra-quite blowers that are strong enough to overcome high static pressure. The composite drain pan quickly removes conden-sate water. Each drain hole is reinforced and has an external stop to prevent over tightening of the screw-in hose barb. Straight or 90-degree hose barbs may be used to better accommodate a variety of installation situations. The blower inlet adapter is made of a high temperature resin to easy withstand the heat generated by the optional internal electric heating element. The manual heater-overload safety switch is easily accessible without disassembling the unit.
Advantages• Rust-free composite drain pan• Drain pan features anti-slosh, ‘positive-flow’ drain channels for no spills and rapid removal of condensate;• Blowers are extremely quiet yet powerful enough to overcome high-static-pressure duct;• Single adjustment screw for 270° of blower rotation;• Blower can be rotated to straight down position for overhead applications;• Vibration isolation mounts reduce noise and vibration;• Flexible mounting options;• Optional flow control automatically balances circulated water throughout the system.• Optional electric heater• Optional EU package upgrades includes several upgrades for reduced installation time and improved appearance
(contact us for more details).
Dimensions
Model (1) AU6DC AU9DC AU12DC AU18DC AU24DC
Capacity (kW) 1.76 2.64 3.52 5.27 7.03
V @ 50/60Hz / 1-Phase 230 230 230 230 230
Amps (FLA) Cool 1.4 1.4 3.17 3.9 3.86
Amps (FLA) Blower 1.4 1.4 3.2 3.9 3.9
Optional heater (kW) 1 1 1.5 3 3
Heater Amps (A) 5.75 7.92 9.69 17 16.9
Max. Circuit breaker (A) 10 10 15 20 20
Min. Circuit breaker (A) 7 9 11 18 18
Water flow (GPM / I / min) 1.5 / 5.7 2.25 / 8.6 3 / 11.4 4.5 / 17.1 6 / 22.8
Air flow (CFM / m3/h) 200 / 340 300 / 510 400 / 680 600 / 1020 700 / 1170
External static pressure (H20 / Pa) 2.9 / 722.1 2.8 / 697.2 2.6 / 647.4 2.1 / 522.9 1.4 / 348.6
Chilled water pressure drop (PS) 1.1 4.4 8 4.6 11
Max. Height (in / mm) (2) 11.7/298 13.4 / 341 13.4 / 341 14.4 / 366 15.5 / 394
Max. Width (in / mm) (2) 14.4/366 16.4 / 417 16.4 / 417 19.9 / 506 22.4 / 569
Max. Depth (in / mm) (2) 14/356 14 / 356 16.7 / 425 17.3 / 440 17.3 / 440
Drain connection type FPT FPT FPT FPT FPT
Drain connection size ½” ½” ½” ½” ½”
Chilled water connection type FPT FPT FPT FPT FPT
Chilled water connection size ½” ½” ½” ½” ½”
Quantity duct connections (in/mm) 1 1 2 2 1
Minimum supply duct size (in/mm) 5 / 125 6 / 153 6 / 153 7 / 178 8 / 204
Minimum supply air grill size (in2 / cm2) 35 / 226 49 / 319 70 / 452 100 / 646 140 / 904
Total return air inlet (in2 / cm2) 70 / 452 98 / 633 130 / 839 200 / 1291 240 / 1549
Gross Weight (lbs/kg) (3) 31 / 14.1 35 / 15.9 42 / 19.1 54 / 24.5 58 / 26.4
1 Model numbers shown are for 115V units with brushless blowers. Add a ‘Z’ for 230V units; add a ‘FC’ for optional control; add a ‘-L’ or ‘-R’ for valve position (relative to the coil) and angle of the blower; add a ‘_kW’ for amount of optional electric heat in kW (for ex. 1.5kW)2 All dimensions ±0.3 inch (8mm). 3 Without electric heat option, subtract 3lbs (1.4kg) from unit weight for each heater element.
Fan Coil Units - HEINEN & HOPMAN 2020 © 12Fan Coil Units - HEINEN & HOPMAN 2020 ©12
AU-HV FAN COIL UNITS
The AU-HV fan coil units are designed for easy installation and high performance. The AU-HV fan coil units feature high velocity (HV) blowers. The positive flow drain pan quickly removes condensate water. Each drain hole is reinforced and has an external stop to prevent over tightening of the screw-in hose barb. To be better accommodate a variety of instal-lation, each drain can accept either a straight or 90° hose barb. Due to the rotatable blower ring, the blower can be rotated easily 270°. The blower inlet adapter is made of a high temperature resin to easy withstand the heat generated by the optional internal electric heating element. The manual heater-overload safety switch is easily accessible without disassembling the unit.
Advantages• Rust-free composite drain pan;• Drain pan features anti-slosh, ‘positive-flow’ drain channels for no spills and rapid removal of condensate;• Single adjustment screw for 270° of blower rotation;• Blower can be rotated to straight down position for overhead applications;• Vibration isolation mounts reduce noise and vibration;• Flexible mounting options;• Optional flow control automatically balances circulated water throughout the system.• Optional electric heater• Optional EU package upgrades includes several upgrades for reduced installation time and improved appearance
(contact us for more details)• Optional air purifier (microparticle air filter)
Dimensions
Model (1) AU6 HV AU9 HV AU12HV AU18HV AU24HV
Capacity (kW) 1.76 2.64 3.52 5.27 7.03
V @ 50/60Hz / 1-Phase 230 115 230 115 230 115 230 115 230 115
Amps (FLA) Cool 00.83 1.56 0.61 1.14 0.78 1.61 2.52 1.18 1.64 3.4
Amps (FLA) Blower 5.18 10.26 4.96 9.84 7.3 14.65 28.61 14.22 14.68 29.49
Optional heater (kW) 1 1.5 1.5 3 3
Max. Circuit breaker (A) 10 15 10 15 10 20 30 15 20 35
Min. Circuit breaker (A) 6 11 6 11 8 16 30 15 16 31
Water flow (GPM / I / min) 1.5 / 5.7 2.3 / 8.8 3 / 11.4 4.5 / 17.1 6 / 22.8
Air flow (CFM / m3/h) 229 / 390 278 / 473 338 / 575 465 / 791 506 / 860
External static pressure (H20 / Pa) 0.3 / 75 0.3 / 75 0.3 / 75 0.3 / 75 0.3 / 75
Chilled water pressure drop (PS) 1.1 4.4 8 4.6 11
Min. Height (in / mm) (2) 11.19 / 285 13.31 / 339 13.31 / 339 13.94 / 355 15.25 / 388
Max. Height (in / mm) (2) 12.13 / 309 13.31 / 339 13.38 / 340 15.38 / 391 16.75 / 426
Max. Width (in / mm) (2) 14.5 / 369 16.5 / 420 16.5 / 420 20.13 / 512 22.63 / 575
Max. Depth (in / mm) (2) 12.65 / 320 13.25 / 337 14.25 / 362 15 / 381 15.38 / 391
Drain connection size (in) ½” ½” ½” ½” ½”
Minimum supply duct size (in/mm) 5 / 127 6 / 153 6 / 153 7 / 178 8 / 204
Minimum supply air grill size (in2 / cm2) 35 / 226 49 / 316 70 / 452 100 / 646 140 / 904
Minimum return air inlet (in2 / cm2) 70 / 452 98 / 633 130 / 839 200 / 1291 240 / 1549
1 Model numbers shown are for 115V units with brushless blowers. Add a ‘Z’ for 230V units; add a ‘FC’ for optional control; add a ‘-L’ or ‘-R’ for valve position (relative to the coil) and angle of the blower; add a ‘_kW’ for amount of optional electric heat in kW (for ex. 1.5kW)2 All dimensions ±0.3 inch (8mm). 3 Without electric heat option, subtract 3lbs (1.4kg) from unit weight for each heater element.
Fan Coil Units - HEINEN & HOPMAN 2020 © 13Fan Coil Units - HEINEN & HOPMAN 2020 ©13
AU-HV FAN COIL UNITS
The AU-HV fan coil units are designed for easy installation and high performance. The AU-HV fan coil units feature high velocity (HV) blowers. The positive flow drain pan quickly removes condensate water. Each drain hole is reinforced and has an external stop to prevent over tightening of the screw-in hose barb. To be better accommodate a variety of instal-lation, each drain can accept either a straight or 90° hose barb. Due to the rotatable blower ring, the blower can be rotated easily 270°. The blower inlet adapter is made of a high temperature resin to easy withstand the heat generated by the optional internal electric heating element. The manual heater-overload safety switch is easily accessible without disassembling the unit.
FC marine fan coil unit• Nominal cooling loads: 10 kW - 70 kW • Spigoted duct connection• Electro-coated mild-steel casing with powder-coated paint finish• Removable front panels for access and maintenance• Quick-release grille for air filter cleaning and replacement• Electrical supply o 380V 3ph 50Hz o 440V 3ph 60Hz• Available options o Plenum and Grille discharge o Color to suit operating environment o Alternative fan pressures o Electric or hot-water heating o Fresh-air connection o Stainless-steel casing
FC10 FC15 FC20 FC30 FC40 FC50 FC70
Nominal cooling load (kW) 10 15 20 30 40 50 70
Nominal air flow (m3/h) 1600 2600 3600 4800 6300 8000 11250
Nominal water flow (m3/h) 0.4 0.6 0.79 1.19 1.59 1.98 2.78
Fan motor rating 0.37 0.55 0.75 1.10 1.50 1.50 2.20
Dimensions H (mm) 1500 1750 1750 1750 1750 2000 2000
W (mm) 500 700 700 700 1200 1200 1500
D (mm) 500 750 750 750 750 750 750
P (mm) 260 270 330 340 340 400 450
Weight (kg) 121 168 185 221 278 303 372
Electric heating (optional) (kW)
1 x 4.5 2 x 4.5 2 x 6.0 2 x 9.0 2 x 9.0 3 x 9.0 4 x 9.0
Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.
Don’t hesitate to contact us for more information about our service options. We are eager to explain the possibilities for your vessel or structure.
Scan the QR-code or visit heinenhopman.com
Fan Coil Units - HEINEN & HOPMAN 2020 © 14Fan Coil Units - HEINEN & HOPMAN 2020 ©14
To stand by our clients in the harshest environments
“ “
14Fan Coil Units - HEINEN & HOPMAN 2020 ©
Fan Coil Units - HEINEN & HOPMAN 2020 © 15Fan Coil Units - HEINEN & HOPMAN 2020 ©15
www.heinenhopman.com
Heinen & Hopman encourages a more
sustainable world. By providing eco-friendly solutions and serviceswe offer our clients
the option of reducing energy consumption
and thus CO2 emissions.
Ventilation Air Conditioning RefrigerationHeating
PROVIDED BYHEINEN & HOPMAN
Inside22ºC
OUTSIDE35°C45°C
HUMIDITY90%40%
AustriaT: +43 1720 1309E: [email protected]
BrazilT: +55 213 587 4241/4244E: [email protected]
CanadaT:+1 450 659 6571E: [email protected]
DenmarkT: +45 5164 1614E: [email protected]
France - La CiotatT: +33 4 4204 8685E: [email protected]
France - AntibesT: +33 4 8902 4562 E: [email protected]
GermanyT:+49 4073 1680E: [email protected]
GermanyT:+49 471 9869 300E: [email protected]
IndiaT: +91 336 499 1293E: [email protected]
ItalyT: +39 187 187 8500E: [email protected]
The Netherlands (HQ)T: +31 33 299 2500E: [email protected]
The Netherlands - RotterdamT: +31 18 020 9210E: [email protected]
NorwayT: +47 6919 0900E: [email protected]
Peoples Republic of ChinaT: +86 213 253 2896E: [email protected]
Peoples Republic of ChinaT: +86 510 8528 1763E: [email protected]
PolandT: +48 914 331 800E: [email protected]
RomaniaT: +40 236 448 222E: [email protected]
RussiaT: +7 812 449 3535E: [email protected]
SingaporeT: +65 6897 7879E: [email protected]
South KoreaT: +82 704 901 0000E: [email protected]
SpainT: +34 932 259 668E: [email protected]
SwedenT: +46 3121 7500E: [email protected]
TurkeyT: +90 216 493 8118E: [email protected]
UAE - Abu Dhabi T:+971 2550 4147E: [email protected]
UAE - DubaiT: +971 4263 5453E: [email protected]
USA - Seattle, Washington T: +1 206 632 7883E: [email protected]
USA - Fort Lauderdale, FloridaT: +1 954 463 0110E: [email protected]
USA - Houma, Louisiana T: +1 985 876 7982E: [email protected]
Do you require more information about our products or do you require advice? I am keen to help you further!
“ “
Paul Spoorenberg- Sales Manager [email protected]