Transcript
Page 1: Equilibar EPC High Resolution Electronic Pressure

1www.equilibar.com© 2021 Equilibar, LLC

The EPC is a high resolution electronic pressure controller that provides a regulated output pressure proportional to an electrical command signal input. The EPC is available in a range of calibrated pressures up to 150 psig (10 bar(g))The EPC can be configured for 0 -10 VDC or 4-20 mA analog signal types or 3.3V serial digital.

The EPC is a complete closed loop control valve consisting of two internal solenoid valves, a manifold, an electronic control circuit board, and a pressure transducer all contained in a protective IP65 rated housing. One solenoid valve functions as inlet control allowing supply media into the system to increase the controlled pressure. The second solenoid valve acts as the exhaust and will decrease the controlled pressure by venting to atmosphere. The inlet solenoid valve operates in a proportional manner to the current supplied by the EPC’s electronic control circuit. The ability to vary the inlet solenoid valve orifice opening in an analog fashion allows the EPC to control pressure with extremely high resolution. The proportional action of the inlet solenoid valve allows the EPC to accurately maintain pressure even when there is a low flow rate due to leaks in the system or other gas consumption. The exhaust solenoid valve also opens proportional to the control circuit current output. This infinitely variable response allows the pressure to be decreased seemessly in your system.

EPCHigh Resolution Electronic Pressure ControllerFOR CONTROLLING GAS PRESSURE UP TO 150 PSI

GENERAL SPECIFICATIONS

Medium Clean, dry, non-corrosive gases

Wetted Material

Elastomers: Nitrile Manifold: Anodized aluminum;

Valves: Nickel plated brass; Sensor: High temperature

polyamide, alumina ceramic, silicone epoxy, glass

IP65 Housing Polycarbonate/ABS blend

Valve Type Normally-Closed

Operating Pressure Range full vaccum to 150 psig

Typical Flow 2.7 to 65 lpm (+10%@100psig)

Typical Response Time <20 ms (application dependent)

Accuracy ±0.25% of full scale

Resolution < 5 mV

Max. Hysteresis ± 0.05% of full scale

Linearity ± 0.05% of full scale

Port Size 1/8" NPT

Temperature Range 32 to 120 °F (0 to 49°C)

Mounting Orientation Any

Recommended Filtration 40 micron

Equipment used for test and calibration is NIST traceable

• Smooth linear control

• Integrated internal or external sensor feedback

• Multiple flow configurations

• Static or dynamic applications with the same proportional control

• Proportional fill and bleed control

• Customizable pressure ranges and mounting options

• No integral bleed required

ELECTRICAL SPECIFICATIONS

Voltage 15 to 24 VDC

Current Draw < 350 mA max

Protection Rating IP65

Signal/Command Options0 to 10 VDC

4 to 20 mA (differential)3.3 V Serial Digital

Precise, linear pressure control within a closed-loop system

with ultra high resolution and repeatability

*Not intended for hazardous/explosive environments. For use with air or inert gases only

Page 2: Equilibar EPC High Resolution Electronic Pressure

2www.equilibar.com© 2021 Equilibar, LLC

3.98(101.1)

0.56(14.2)

2.50 (63.5)1.50 (38.1)

1.00(25.4)

1.50(38.1)

#6-32 thd.-0.25 deepmtg. thd. 2 plcs.

1.22 (31.0)

1.00(25.4)

0.30 (7.62)EXH OUTIN

OUTEXHIN

OUT

4.54(115.3)

0.74(18.7)

1.70(43.2)

0.75(19.1)

0.74(18.7)

inlet/supply1/8” NPT (G1/8)

exhaust/vent1/8” NPT (G1/8)

outlet/work1/8” NPT (G1/8)

1.25(31.8)

aux. outlet/work1/8” NPT (G1/8) plugged

#6-32 thd.-0.2 deepbracket/mtg. holes(2) plcs.

1.50(38.1)

A6

7

8

1

2

34

5

A

3.25 (82.6)

0.75(19.1) 1.50

(36.8)

0.20 dia. (2) plcs.

3.63 (92.1)

0.31 (8.0)

0.06(1.6)

1.14(28.9)

2.00 (50.8)

3.19(81.03)

0.31 (7.75)0.31 (7.75) 0.31 (7.75)0.45

(11.43)0.45

(11.43)0.45

(11.43)

A

inlet/supply1/8” NPT (G1/8)

exhaust/vent#10-32 (M5)

outlet/work1/8” NPT (G1/8)1 7

3 5

2 84 6

A

1.76 (44.7)

0.74 (18.7)

0.15 dia. mtg. holes (2) plcs.

matingelectricalconnector(provided)

EXH

0.31 (7.75)0.45

(11.43)exhaust/vent#10-32

Made in the USA

Equilibar’s quality system is ISO 9001:2015 certified. ©Equilibar December 2021 R2

Equilibar provides innovative and robust pressure and flow control technology for researchers and engineers worldwide. We are proud to design, manufacture, and test our patented back pressure regulators in our factory overlooking the Blue Ridge Mountains near Asheville, NC, and we are equally proud to work with clients around the world each and every day.

APPLICATION ENGINEERING–WHAT SETS US APARTUnlike mass-market regulator distributors, we focus on working with you, the scientist or engineer with a complex pressure control scenario.

Our application engineers work collaboratively with clients to identify the optimal model, trim, and diaphragm for each application’s unique challenges. No matter where you are on the globe, you can stay in close contact with your engineer by email, telephone, videoconferencing, or fax.

About Equilibar

Equilibar, LLC 320 Rutledge Rd.

Fletcher, North Carolina 28732 United States

Tel: +1-828-650-6590 [email protected]

1 MODEL

EPC Electronic Pressure Controller

2 TYPE

H IP65 Housing

3 PORT THREAD TYPE

F 1/8" NPT

G G1/8 (option available)

4 INPUT SIGNAL COMMAND

E 0 to 10 VDC

I 4 to 20 mA (differential)

R 3.3V Serial Digital

5 PRESSURE RANGE

A 0 to 1 psig

B 0 to 5 psig

C 0 to 15 psig

D 0 to 30 psig

E 0 to 60 psig

F 0 to 100 psig

G 0 to 150 psig

H 0-30 in Hg (vacuum)

I 0-760 Torr (absolute)

6 MIN VOLUME / MAX FLOW RATE

X Factory selected based on customer application

EPC Part Number Key1 2 3 4 5 6

EXAMPLE PART NUMBER EPC H F E G A

Your Part Number: EPC H

(Items listed in blue are often in stock for faster delivery)

Application engineers will use your process parameters to specify the model number for your application


Recommended