Transcript
Page 1: ENTRY GATE K.B. ROAD BATTERY LIMIT OF STP CONTRACT · from sas pumps centrifuge house 51.5 deweterted sludge to disposal fgl.50.25 52.5 49.00 thickener to sludge tank 54.5 51.0 il

WALKWAY

PROPOSED BL 46.00 M

LVL 50.25 M

RAILING

PROPOSED

COMPOUNDL WALL

FSL 49.50 M

6.00

TEMPORARY STEEL

SHEET PILE

WIRE FENCING

0.250

1.00

BEEL WATER

EGL 47.00 M

FGL 50.00 M (APPX)

BATTERY LIMIT

B

O

R

S

O

L

A

B

E

E

L

INLET

K.B

. RO

AD

2

6

.5

2.6

X

X

STEEL SHEET PILE

COMPOUND WALL

BATTERY LIMIT

RETAINING WALL

B

O

R

S

O

L

A

B

E

E

L

B

O

R

S

O

L

A

B

E

E

L

C

H

.

1

7

3

M

C

H

.

0

0

M

C

H

.

3

0

0

M

C

H

.

4

0

0

M

C

H

.

5

0

0

M

C

H

.

6

0

0

M

C

H

.

7

0

0

M

C

H

.

8

0

0

M

C

H

.

1

2

5

5

M

C

H

.

1

2

5

M

C

H

.

1

5

0

M

C

H

.

2

1

0

M

C

H

.

9

0

0

M

C

H

.

1

0

0

0

M

C

H

.

1

1

0

0

M

C

H

.

1

2

0

0

M

ENTRY GATE

03

12

BATTERY LIMIT OF STP

CONTRACT

I

N

L

E

T

O

U

T

L

E

T

R

O

A

D

X

X

S

T

E

E

L

S

H

E

E

T

P

I

L

E

C

O

M

P

O

U

N

D

W

A

L

L

APPD

I&C

DATE

CIVIL

DRN

ELEC

DO NOT SCALE

DATE

DATE (R0 ISSUE)

ISSUE

SCALE: 1:1000

CHD:

DRN:

:

:

DATE

FILE NAME

CLIENT

:PROJECT

APPROVED

NO

DWG

CLEARED

ISSUE

SIGNATURE

CLEARED

CIVIL

DEPT

MECH

ELEC

I&C

FOR R0 ISSUE ONLY

REVISIONS

CONSULTING ENGINEERS LIMITED

MUMBAI

TCE FORM NO. 042 R5

FILE NAME: F-041-Rev-R5.dwg

SIZ

E-A

2

GUWAHATI SMART CITY LIMITED

PROPOSED 15 MLD STP AT BORSOLA BEEL

GUWAHATI SMART CITY LIMITED

BATTERY LIMIT OF CONTRACT

15 MLD STP AT BORSOLA BEEL

TENDER PURPOSE ONLY

ALL THE LEVELS AND DIMENSIONS ARE INDICATIVE.

DETAIL & DESIGN DRAWINGS SHOULD BE PREPARED

BY THE CONTRACTOR AFTER PERFORMING NECESSARY INVESTIGATION.

BATTERY LIMIT OF STP CONTRACT

P0

KEY PLAN

SECTION X-X

(SCALE 1 :100)

STEEL SHEET PILE

BATTERY LIMIT

LEGENDS

Page 2: ENTRY GATE K.B. ROAD BATTERY LIMIT OF STP CONTRACT · from sas pumps centrifuge house 51.5 deweterted sludge to disposal fgl.50.25 52.5 49.00 thickener to sludge tank 54.5 51.0 il

BORSOLA BEEL

500 MM Ø PILE

@20 M DEPTH

@1 M C/C

RL 45.75

RL 50.25

RAILING-R2

(AS PER DETAIL)

RAILING-R1

(AS PER DETAIL)

RETAINING WALL OF HEIGHT 4.5 M AND ROAD

RTL (+) 50.00 m

INTERNAL ROAD

SECTION P-P

CONSULTING ENGINEERS LIMITED

MUMBAI

GUWAHATI SMART CITY LIMITED

LAYOUT OF PROPOSED 15 MLD STP AND

CROSS SECTION OF RETAINING WALL AND ROAD

AT BORSOLA BEEL

TENDER PURPOSE ONLY

ALL THE LEVELS AND DIMENSIONS ARE INDICATIVE.

DETAIL & DESIGN DRAWINGS SHOULD BE PREPARED

BY THE CONTRACTOR AFTER PERFORMING NECESSARY INVESTIGATION.

Page 3: ENTRY GATE K.B. ROAD BATTERY LIMIT OF STP CONTRACT · from sas pumps centrifuge house 51.5 deweterted sludge to disposal fgl.50.25 52.5 49.00 thickener to sludge tank 54.5 51.0 il

RECIEVING

FINE SCREEN

CHAMBER

SLUDGE

DEWATERING

DRIED SLUDGE FOR DISPOSAL

GSF

TWT

FOR DISPOSAL

POLYELECTROLYTE

BLOWERS

LEGEND :

SEWAGE

SLUDGE

SUPERNATANT/CENTRATE/FILTRATE

SLUDGE/FILTRATE PUMP HOUSE

DEGRITTING SYSTEM

(WITH OIL AND

BLOWERS

BACKWASH TO

SHT

TREATED WATER TANKTWT

SLUDGE HOLDING TANKSHT

STILLING CHAMBER

TREATED SEWAGE

FFP

FFT

CLEAR WATER TANKCWT

OIL FOR DISPOSAL

SCREENED MATERIAL

FOR DISPOSAL

PRIMARY TREATMENT

SECONDARY TREATMENT TERTIARY TREATMENT

GREASE CHAMBER)

GRIT FOR DISPOSAL

PUMPING

STATION

COARSE

CHAMBER

SCREEN

CHAMBER

SEWAGE

CENTRATE

TO STILLING CHAMBER

FILTER FEED PUMPFFP

SBTU

AT

CCT

CHAMBER

STILLING

INCOMING

SEWER

SECONDARY BIOLOGICAL TREATMENT UNIT SBTU

FILTER FEED TANKFFT

GRAVITY SAND FILTERGSF

CHLORINE CONTACT TANKCCT

CHLORINE DOSING

AIREATION TANKAT

DO NOT SCALE

DATE

DATE (R0 ISSUE)

ISSUE

SCALE: NTS

CHD:

DRN:

:

:

DATE

FILE NAME

CLIENT

:PROJECT

APPROVED

NO

DWG

SIGNATURE

CLEARED

CIVIL

DEPT

MECH

ELEC

I&C

FOR R0 ISSUE ONLY

CONSULTING ENGINEERS LIMITED

MUMBAI

GUWAHATI SMART CITY LIMITED

BORSOLA BEEL 15 MLD STP

GUWAHATI SMART CITY LIMITED

PROCESS FLOW DIAGRAM OF

PROPOSED 15 MLD STP AT BORSOLA BEEL

TENDER PURPOSE ONLY

ALL THE LEVELS AND DIMENSIONS ARE INDICATIVE.

DETAIL & DESIGN DRAWINGS SHOULD BE PREPARED

BY THE CONTRACTOR AFTER PERFORMING NECESSARY INVESTIGATION.

P0

Page 4: ENTRY GATE K.B. ROAD BATTERY LIMIT OF STP CONTRACT · from sas pumps centrifuge house 51.5 deweterted sludge to disposal fgl.50.25 52.5 49.00 thickener to sludge tank 54.5 51.0 il

STILLINGCHAMBER

FINE SCREEN GRIT CHAMBER

TWL.56.4TWL.56.3 TWL.55.95

TWL.55.9

TWL.55.60

FGL.50.25

55.4 TWL.55.3

TWL. 51.6

TOC. 49.50

54.9

RAS SAS

55.1

BWL. 52.9

TWL.55.50

SPLITTER BOX

TWL.56.00

CHLORINATION TANKTOC. 48.9

TO SLUDGE SUMP

TWL. 53.85

46.8346.53

49.05

46.83

46.05

FGL.50.25

TOC.42.13

46.53INCOMING SEWER 46.05WATER BODY

FSL 49.50

THICKENED SLUDGE SUMP

51.0

49.0

56.0

60.5

FGL.50.25

TO STILLING CHAMBER

FROM SAS PUMPS

CENTRIFUGE HOUSE

51.5

DEWETERTED SLUDGE TO DISPOSAL

FGL.50.25

52.5

49.00

THICKENER

TOSLUDGE

TANK

54.5

51.0IL. 50.4

IL. 49.9SLUDGE SUMP

49.9

45.9

BACK WASH SUMP

RECEIVING CHAMBERCOARSE SCREEN

CHAMBER

TERMINAL SEWAGE PUMPING STATION

50.8

THICKENERFEED PUMP

FEED PUMP

SEWAGE TRANSFER PUMP

BACK WASHWATER TRANSFER PUMP

FILTER FEED PUMP

THICKENED SLUDGE TRANSFER PUMP

54.9

TWL.55.55

54.40

TWL. 51.1TWL. 50.9

59.60

TWL. 51.30TWL. 51.35

TWL. 50.96

RGSF

TWL. 53.85

50.8

49.7

50.55

55.55

54.60

46.35

FGL.50.25

SECONDARYBIOLOGICALTREATMENTUNIT

FROM CHLORINATIONSYSTEM

DEW

ETER

TED

SLU

DG

E

CENTRIFUGE

CENTRATE TO STILLING CHAMBER

CENTRIFUGE

LEGEND :

PUMP

TOP WATER LEVELTWL

FINISHED GROUND LEVELFGL

BOTTOM WATER LEVELBWL

INVERT LEVELIL

TOP OF CONCRETETOC

RAPID GRAVITY SAND FILTERRGSF

RETURN ACTIVATED SLUDGERAS

SURPLUS ACTIVATED SLUDGE SAS

FULL SERVICE LEVELFSL

DO NOT SCALE

DATE

DATE (R0 ISSUE)

ISSUE

SCALE: 1:125

CHD:

DRN:

:

:

DATE

FILE NAME

CLIENT

:PROJECT

APPROVED

NO

DWG

SIGNATURE

CLEARED

CIVIL

DEPT

MECH

ELEC

I&C

FOR R0 ISSUE ONLY

CONSULTING ENGINEERS LIMITED

MUMBAI

GUWAHATI SMART CITY LIMITED

BOROSOLA BEEL 15 MLD STP

GUWAHATI SMART CITY LIMITED

TCE.10477A-EV-2032-FD-2107

HYDRAULIC FLOW DIAGRAM OF

15 MLD STP AT BORSOLABEEL

TENDER PURPOSE ONLY

ALL THE LEVELS AND DIMENSIONS ARE INDICATIVE.

DETAIL & DESIGN DRAWINGS SHOULD BE PREPARED

BY THE CONTRACTOR AFTER PERFORMING NECESSARY INVESTIGATION.

P0

Page 5: ENTRY GATE K.B. ROAD BATTERY LIMIT OF STP CONTRACT · from sas pumps centrifuge house 51.5 deweterted sludge to disposal fgl.50.25 52.5 49.00 thickener to sludge tank 54.5 51.0 il

PGPG

CAUSTIC SOLUTION

INLET

AIR

BLOWER

PG

PG

CHAMBER

SLTILLING

RAS PUMP SAS PUMP

RAS PUMP SAS PUMP

M M M

M

M M M

M

M M M

M

TO STILLING

CHAMBER

FOR DECANTERSVFD

VFD

LT

PI

MK.NO.

DO

VARIABLE FREQUENCY DRIVE

VARIABLE FREQUENCY DRIVE

DISSOLVED OXYGEN METER

LEVEL TRANSMITTER

PRESSURE GAUGES

DESCRIPTION

FOR BLOWERS

BOURDON TYPE

REMARK

IMMERSION TYPE

INSTRUMENT LIST

DELS DECANTER LEVEL SENSOR

MERCURY FLOAT

DEPSDECANTER POSITION SENSOR

PRESSURE GAUGESPI DIAPHRAGM TYPE

FLOW TRANSMITTERFT

LEVEL SWITCHLS

LT LEVEL TRANSMITTER

ULTRASONIC TYPE

ULTRASONIC TYPE

CAPACITANCE TYPE

HYDROSTATIC TYPE

DLTLEVEL TRANSMITTER

DIFFERENTIAL

ULTRASONIC TYPE

SWITCH

MAGNETIC LIMIT

SWITCH

DIFFERENTIAL

DESCRIPTION

CHLORINATION TANK OUTLET

INCOMING SEWER

B

A

MK.NO. PRESSURE

ATMOSPHERIC

ATMOSPHERIC

REMARK

TERMINATION POINT

RCC CHANNEL

AIR LINE

SAS LINE

INSTRUMENT SIGNAL

DRAIN LINE

RAS LINE

NEEDLE VALVE

NON-RETURN VALVE

BUTTERFLY VALVE

BALL VALVE

GATE

BUTTERFLY VALVE

MOTORISED

DRIVE

VARIABLE FREQUENCY

MOTORIZED

KNIFE GATE VALVE

MOTORISED GATE

CHANNEL MOUNTED

SOFT STARTER

MOTOR

AIR BLOWER

SILENCER

FILTER

NOTES:

DO NOT SCALE

DATE

DATE (R0 ISSUE)

ISSUE

SCALE: 1:2000

CHD:

DRN:

:

:

DATE

FILE NAME

CLIENT

:PROJECT

APPROVED

NO

DWG

SIGNATURE

CLEARED

CIVIL

DEPT

MECH

ELEC

I&C

FOR R0 ISSUE ONLY

CONSULTING ENGINEERS LIMITED

MUMBAI

GUWAHATI SMART CITY LIMITED

BORSOLA BEEL 15 MLD STP

GUWAHATI SMART CITY LIMITED

P & I DIAGRAM OF

15 MLD STP AT BORSOLA BEEL

TENDER PURPOSE ONLY

ALL THE LEVELS AND DIMENSIONS ARE INDICATIVE.

DETAIL & DESIGN DRAWINGS SHOULD BE PREPARED

BY THE CONTRACTOR AFTER PERFORMING NECESSARY INVESTIGATION.

P0


Recommended