PEUGEOT/CITROËNNo. 19500537RC
407 Saloon 05/04 407 Station Wagon 09/04 407 Coupé 10/05 C6 01/0608/08 08/08 08/08
Right Connections (UK) Limited7 Churchill Buildings, Queen Street,Wellington, Telford, Shropshire TF1 1HT
Hotline: +44 0871 226 2030Fax - UK only: 0870 759 8366
Web: www.rightconnections.co.ukemail: [email protected]
87500896 / 03.03.2009
© ConWys AG1/14
Installation of the towing electrics kit must be undertakenby a specialist workshop or an appropriately qualifiedperson. Before starting work, you must read the installationinstructions through completely. After installing the towingelectrics kit, the installation instructions should be keptwith the vehicle service documentation.
All claims under the guarantee will lapse in case of improper use ormodification of the towing electrics kit or any of its component parts.When driving without a trailer or load carrier, any adapter installedmust be removed from the electrical socket. We reserve the right toalter the design, content or colour. We accept no liability for anyerrors in these instructions. All details and illustrations are non-binding.
Fitting instructions
In case of missing a rear fog lamp on the trailer, it should be retrofitted.
We accept no responsibility and give no guarantee for technical andelectrical modifications made after the initial operation of the towingelectrics kit by the vehicle manufacturer and which may lead, forexample to malfunction of the trailer socket or its peripheries.
The trailer module is not diagnostics-capable. If the manufacturer’sdiagnostics processes or software-supported test mechanismsgenerate error reports directly or indirectly linked with trailer operation,the trailer module must be disconnected from the leads to the trailersocket and a new diagnostic process initiated.
Electric wiring kit for towbars / 7-pin / 12N / 12 Volt / ISO 1724
IMP
OR
TAN
T!
MANUAL
3x 8x 3x
2x
2x90270328
16-50
6-7, 9-13
50A
30A
Right Connections (UK) Limited7 Churchill Buildings, Queen Street,Wellington, Telford, Shropshire TF1 1HT
Hotline: +44 0871 226 2030Fax - UK only: 0870 759 8366
Web: www.rightconnections.co.ukemail: [email protected]
87500896 / 03.03.2009
© ConWys AG2/14
SYMBOL EXPLANATION
+ -
15+
+-
30+
Reverse
B+/30
20A
left (58-L) respectivelyright (58-R) tail light
stop light (54) /high mounted, third stop light (54)
turn signal indicator left
turn signal indicator right
rear fog light(s)
reversing light(s)
Permanent power supply /13pin socket, chamber 9
charging wire for trailer fridge /13pin socket, chamber 10
trailer / trailer recognition
Permanent current power supply
Ground or Earth (31)
ground connection battery terminal lug
positive connection battery terminal lug
fuse / fuse capacity 20 Ampère
12V
P
cigarette lighter /accessory socket
loudspeaker / buzzer
Park Distance Control
switch / source of function
Connect together
Disconnect
Look at / See further information
Look carefully at selected area
Present / Occupied / OK
Not present / Not occupied / Not OK
left
right
acoustic indication
attention / important advice
90500760
everse
1Right Connections (UK) Limited7 Churchill Buildings, Queen Street,Wellington, Telford, Shropshire TF1 1HT
Hotline: +44 0871 226 2030Fax - UK only: 0870 759 8366
Web: www.rightconnections.co.ukemail: [email protected]
87500896 / 03.03.2009
© ConWys AG3/14
MANUAL
IMPORTANT!
90010216
In order to avoid mal-functions and damage to the vehicle’s electrical systemthe earth terminal must be disconnected from the vehicle’s battery beforestarting work!
Both the trailer module and the vehicle’s control unit for the electrical systemcan be damaged during work on the CAN data bus connections if the batteryis not disconnected!
Please pay attention to the manufacturer’s instructions when disconnectingand reconnecting the vehicle’s battery!
90160086
Right Connections (UK) Limited7 Churchill Buildings, Queen Street,Wellington, Telford, Shropshire TF1 1HT
Hotline: +44 0871 226 2030Fax - UK only: 0870 759 8366
Web: www.rightconnections.co.ukemail: [email protected]
87500896 / 03.03.2009
© ConWys AG4/14
90160088
2 3
4 5
6
7 8
25 mm
90110003
D FGB IE
RD
BK
GN
OR
VT
PK
BL
YL
WT
BR
GY
Black Schwarz Negro Noir Nero
Red Rot Rojo Rouge Rosso
Green Grün Verde Vert Verde
Orange Orange Naranja Orange Arancione
Violet Violett Violeta Violet Viola
Pink Pink Pink Rose Rosa
Blue Blau Azul Bleu Blu
Yellow Gelb Amarillo Jaune Giallo
White Weiss Blanco Blanc Bianco
Brown Braun Marrón Brun Marrone
Grey Grau Gris Gris Grigio
NL NP SDK
Preto Zwart Sort Svart
Vermelho Rood Rød Rød Röd
Verde Groen Grøn Grønt Grön
Laranja Oranje Orange Orange Orange
Violeta Violet Violet Fiolett Violett
Cor-de-Rosa Paars Pink Pink Rosa
Azul Blauw Blå Blått Blå
Amarelo Geel Gul Gult Gul
Branco Wit Hvid Hvitt Vit
Marrom Bruin Brun Brunt Brun
Cinzento Grijs Grå Grått Grå
CZFIN H
Musta Cerná Fekete
Punainen Cervená Piros
Vihreä Zelená Zöld
Oranssi Narancs
Violetti Fialová Ibolya
Pinkki Ruzová Rózsaszín
Sininen Modrá Kék
Keltainen Zlutá Sárga
Valkoinen Bílá Fehér
Ruskea Hnedá Barna
Harmaa Sedá Szürke
PL
Czarny
Czerwony
Zielony
Pomaranczowy
Fioletowy
Rózowy
Niebeski
Zólty
Bialy
Brazowy
Szary
Svart
Oranzová
90500580
90500548
Belegung der Steckdose/Socket ConfigurationCorrespondance des Contacts de la priseCavi della presa ellettrica sono abbinatiIndeling van de stekkerdoos / maximaal uitgangsvermogen
ISO 1724
5/58-R
6/54STOP
1/L
4/R
2
3/31
BK/WT
WT
BK/GN
BR
GY/RD
BK/RD
7/58-L GY/BK
21W
42W
21W
52W
63W
52W90500167
90500380
Right Connections (UK) Limited7 Churchill Buildings, Queen Street,Wellington, Telford, Shropshire TF1 1HT
Hotline: +44 0871 226 2030Fax - UK only: 0870 759 8366
Web: www.rightconnections.co.ukemail: [email protected]
87500896 / 03.03.2009
© ConWys AG5/14
15- 3952 - 65 40 - 65
13
14
9
11 12
10
90500002
16 - 2652 - 65
27-3952 - 65
Right Connections (UK) Limited7 Churchill Buildings, Queen Street,Wellington, Telford, Shropshire TF1 1HT
Hotline: +44 0871 226 2030Fax - UK only: 0870 759 8366
Web: www.rightconnections.co.ukemail: [email protected]
87500896 / 03.03.2009
© ConWys AG6/14
90160083
chamber 1
90160082
BLB+/30)
BLB+/30)
90160081
BLB+/30)
BRBR
17
18
19 20
15
Right Connections (UK) Limited7 Churchill Buildings, Queen Street,Wellington, Telford, Shropshire TF1 1HT
Hotline: +44 0871 226 2030Fax - UK only: 0870 759 8366
Web: www.rightconnections.co.ukemail: [email protected]
87500896 / 03.03.2009
© ConWys AG7/14
Important!Please note informations in picture 1!
90030147
50A
90160084
21
CAN Data Wire
Important!Please note informations in picture 1!
90030146
notneeded!
22
23
24
90060322
Right Connections (UK) Limited7 Churchill Buildings, Queen Street,Wellington, Telford, Shropshire TF1 1HT
Hotline: +44 0871 226 2030Fax - UK only: 0870 759 8366
Web: www.rightconnections.co.ukemail: [email protected]
87500896 / 03.03.2009
© ConWys AG8/14
BLB+/30)
90160098
BLB+/30) BL
B+/30)
chamber 190160082
BLB+/30)
25 26
27 28
29
30 31
30A
90030139
50A
6th position from leftOPTION 2
2nd position from leftOPTION 1
WT/BKWTWT
WTWT/RD
BL
RD
chamber 2
90160099
Right Connections (UK) Limited7 Churchill Buildings, Queen Street,Wellington, Telford, Shropshire TF1 1HT
Hotline: +44 0871 226 2030Fax - UK only: 0870 759 8366
Web: www.rightconnections.co.ukemail: [email protected]
87500896 / 03.03.2009
© ConWys AG9/14
90160083
90160100 90160101
90160084 90160101
Important!Please noteinformations in picture 1!
36 37
Important!Please note informations in picture 1!
90030147
32 33
34 35
38
87220019 / 23.04.2002 / Seite 2/4 / © JAEGER automotive GmbH / Chromstrasse 90 /D- 33415 Verl / FON: +49 5246-9210-0 / FAX: +49 5246-9210-20 /e-mail: [email protected]
90160098
chamber 1
90160082
BL
RD
chamber 2
90160099
Right Connections (UK) Limited7 Churchill Buildings, Queen Street,Wellington, Telford, Shropshire TF1 1HT
Hotline: +44 0871 226 2030Fax - UK only: 0870 759 8366
Web: www.rightconnections.co.ukemail: [email protected]
87500896 / 03.03.2009
© ConWys AG10/14
BLB+/30)
BLB+/30)
BLB+/30)
40 41
4342
44 45
39
90160083
BRBR
87220019 / 23.04.2002 / Seite 2/4 / © JAEGER automotive GmbH / Chromstrasse 90 /D- 33415 Verl / FON: +49 5246-9210-0 / FAX: +49 5246-9210-20 /e-mail: [email protected] Connections (UK) Limited7 Churchill Buildings, Queen Street,Wellington, Telford, Shropshire TF1 1HT
Hotline: +44 0871 226 2030Fax - UK only: 0870 759 8366
Web: www.rightconnections.co.ukemail: [email protected]
87500896 / 03.03.2009
© ConWys AG11/14
90160101
90500652
Supplementary harness
12S38400501
BL/YL
OPTIONALeverse
46 4790160100
50
48 49
51 52
90160101
Important!Please noteinformations in picture 1!
90160084
Important!Please note informations in picture 1!
90030147
87220019 / 23.04.2002 / Seite 2/4 / © JAEGER automotive GmbH / Chromstrasse 90 /D- 33415 Verl / FON: +49 5246-9210-0 / FAX: +49 5246-9210-20 /e-mail: [email protected]
90160086
MANUAL
90500004
Right Connections (UK) Limited7 Churchill Buildings, Queen Street,Wellington, Telford, Shropshire TF1 1HT
Hotline: +44 0871 226 2030Fax - UK only: 0870 759 8366
Web: www.rightconnections.co.ukemail: [email protected]
87500896 / 03.03.2009
© ConWys AG12/14
90500708
MANUAL
9027030990500507
everse
53 54
55 56
57 58
59 60
87220019 / 23.04.2002 / Seite 2/4 / © JAEGER automotive GmbH / Chromstrasse 90 /D- 33415 Verl / FON: +49 5246-9210-0 / FAX: +49 5246-9210-20 /e-mail: [email protected] Connections (UK) Limited7 Churchill Buildings, Queen Street,Wellington, Telford, Shropshire TF1 1HT
Hotline: +44 0871 226 2030Fax - UK only: 0870 759 8366
Web: www.rightconnections.co.ukemail: [email protected]
87500896 / 03.03.2009
© ConWys AG13/14
62
61
63
64
90500331
13-pin7-pin
Optional: Adapter socket 62400001
P
90500545
P
MANUALSERVICE
PEUGEOT
PEUGEOTSERVICE
PEUGEOT
PEUGEOT
90270310
MANUAL
87220019 / 23.04.2002 / Seite 2/4 / © JAEGER automotive GmbH / Chromstrasse 90 /D- 33415 Verl / FON: +49 5246-9210-0 / FAX: +49 5246-9210-20 /e-mail: [email protected] Connections (UK) Limited7 Churchill Buildings, Queen Street,Wellington, Telford, Shropshire TF1 1HT
Hotline: +44 0871 226 2030Fax - UK only: 0870 759 8366
Web: www.rightconnections.co.ukemail: [email protected]
87500896 / 03.03.2009
© ConWys AG14/14
The activation of
• trailer indicator monitoring• PDC deactivation
has to be carried out using theCITROËN Proxia tester as follows:
Set up trailer operation
Set up trailer operation
The activation of
• trailer indicator monitoring• PDC deactivation
must be carried out using the PEUGEOT PPS Testerand PEUGEOT Planet Office Softwareas follows:
• Select the vehicle• Select the application Peugeot Planet 2000• Optional extras• Tow hook• Installation towbar
90160121
Module programming
• Remote loading/remote coding• Remote coding• Select vehicle type• Central unit (BSI)• Manual remote coding• Configuration• Vehicle definition – equipment - driving information• Presence of trailer switch unit (BSR) Yes
65
66