7/31/2019 Economical Design of Earhquake Resistant Structure
1/26
AMARDEEP KAUR
M.TECH(STRUCTURES)
7/31/2019 Economical Design of Earhquake Resistant Structure
2/26
INTRODUCTION
With the occurrence of every major earthquake, there has been in thepast, almost a world-wide tendency to increase the capacity demand ofthe structure to counteract such events.
It is only in the last decade that new strategies have been successfully
developed to handle this problem economically. There is an increasing realization that apart from techniques for
improving ductility, the structural engineers tool-box should includeenergy-dissipating and energy-sharing devices and those that cancontrol the response of the system.
There have also been further advances on appropriate methods anddevices of preventing dislodgement or unseating of thesuperstructure in the event of severe ground shaking. How these ideascan be used in economical earthquake resistant design of bridges is thesubject of this paper
7/31/2019 Economical Design of Earhquake Resistant Structure
3/26
PLASTIC HINGING AND DURABILITY
There is a marked difference in seismic design aspects of bridgesand buildings.
The reduced degree of indeterminacy of bridge structures leadsto reduced potential of dissipating energy and load
redistribution. In bridges, the superstructures (piers and abutments) are the
main structural elements provide resistance to seismic action.
This essentially means that the formation of plastic hinges orflexural yielding is allowed to occur in these elements during
severe shaking to bring down the lateral design forces toacceptable levels.
Since yielding would lead to damage, plastic hinging arelocalized by design at points accessible for inspection and repair,no plastic hinges are, of course, allowed to occur in the
foundations or in the bridge deck.
7/31/2019 Economical Design of Earhquake Resistant Structure
4/26
Well-designed structures dissipate seismic energy by inelastic deformations inlocalized zones of selected members
PLASTIC HINGING AND DURABILITY
7/31/2019 Economical Design of Earhquake Resistant Structure
5/26
Cont.. Ductile behavior is ensured by confinement of the concrete
compression zone lying in the plastic hinge region of thesub-structures.
Closely spaced horizontal hoops, restraining the main
vertical reinforcement bars of the substructure, areeffectively used for this purpose.
The main functions of the hoops and ties in thesubstructure can be summarized as follows:
Confining of concrete core so as to enhance concrete strengthsand to sustain higher compressive strains,
Restrain longitudinal reinforcement against buckling,
Provide shear resistance during flexure
7/31/2019 Economical Design of Earhquake Resistant Structure
6/26
Confinement of column sections by
transverse and longitudinal reinforcement
A. Circular hoops orspiral
B. Rectangular hoops withcross ties
7/31/2019 Economical Design of Earhquake Resistant Structure
7/26
Confinement of column sections by
transverse and longitudinal reinforcement
D. Overlappingrectangular hoops
C. Rectangularoctagonal hoops
7/31/2019 Economical Design of Earhquake Resistant Structure
8/26
Confinement of column sections by
transverse and longitudinal reinforcement
E. Confinement bytransverse bars
F. Confinement bylongitudinal bars
7/31/2019 Economical Design of Earhquake Resistant Structure
9/26
SUPERSTRUCTURE DISLODGEMENT PREVENTION
AND INTEGRAL BRIDGES
Bearings, in general, are comparatively fragile andbrittle elements
Usual bearings of various types (metallic, elastomeric,pot, etc.) can be designed to have the capacity ofsustaining lateral forces of about 25-30% of theirvertical load carrying capacity (IRC, 1999).
For larger lateral forces, as in the cases of Zones IV andV (IRC, 2000), it is more suitable and economical toprovide
7/31/2019 Economical Design of Earhquake Resistant Structure
10/26
Resistance to these forces separately by some otherstructural element
In many earthquakes it was noticed that thesuperstructure was dislodged and had fallen onto theground or was damaged due to loss of support causedby large displacements of elastomeric bearings or dueto out-of-phase displacement of piers.
SUPERSTRUCTURE DISLODGEMENT PREVENTION
AND INTEGRAL BRIDGES
7/31/2019 Economical Design of Earhquake Resistant Structure
11/26
Provide reaction blocks or other types of seismicrestrainers for preventing dislodgement ofsuperstructure at pier/abutment cap level,
Provide adequate support lengths for superstructure
on pier/abutment cap
Design and construct integral bridges whereby thesubstructure and superstructure can be mademonolithic
SUPERSTRUCTURE DISLODGEMENT PREVENTION
AND INTEGRAL BRIDGESTo counteract such failures the following counter
measures are suggested:
7/31/2019 Economical Design of Earhquake Resistant Structure
12/26
Surajbari Old Bridge: Metallicbearings destroyed duringearthquake
Girder shifted in the longitudinal
direction with loss of seatingduring shaking
7/31/2019 Economical Design of Earhquake Resistant Structure
13/26
Example of longitudinal seismicrestrainer for continuous bridges
Britannia Chowk Flyover:Elevation of restrained pier
Longitudinal seismic restrainer (vertical
elastomeric pad introduces damping tolongitudinal forces)
7/31/2019 Economical Design of Earhquake Resistant Structure
14/26
Prevention of dislodgement
Longitudinal Tie Bars Holding-Down Bars
7/31/2019 Economical Design of Earhquake Resistant Structure
15/26
Integral bridges need wide exposure because bearingsand expansion joints are elements that are of seriousconcern in earthquake-prone areas
As already mentioned, they also happen to be theweak points in bridge structures from the point of viewof strength, durability and maintenance
Their elimination in many types of bridges has now
become a distinct possibility. Whereas theemployment of advanced design techniques isessential, the construction could possibly becomesimpler and safer.
SUPERSTRUCTURE DISLODGEMENT PREVENTION
AND INTEGRAL BRIDGES
7/31/2019 Economical Design of Earhquake Resistant Structure
16/26
cont... Integral bridges can be made earthquake-resistant
more conveniently than bridges with bearings.
Apart form obviating the necessity of providingseismic restrainers and/or wide support lengths for the
superstructure, the number of potential locations ofplastic hinges can be increased, and ductility of a highorder introduced into the system.
The associated problems of a deck with significant
skew (700) were overcome
7/31/2019 Economical Design of Earhquake Resistant Structure
17/26
Flyover using Integral Bridge concept for Delhi Metro (the curved flyover
has 70 skew and has no bearings or expansion joints on piers/abutments;length: 115 m)
Kalkaiji Flyover: Integral construction, high durability, low
maintenance, increased safety during earthquakes
7/31/2019 Economical Design of Earhquake Resistant Structure
18/26
BASE ISOLATION, ENERGY DISSIPATION AND
ELASTOMERIC BEARINGS The use of special devices that reduce the seismic forces
can be effectively utilized in the structure. By decouplingthe structure from seismic ground motions it is possible to
reduce the earthquake-induced forces in it. This can bedone in two ways:
Increase natural period of the structure by base isolation,
Increase damping of the system by energy-dissipatingdevices.
The central issues are to limit the seismic energy enteringinto the structure from the ground in the first place andthen to dissipate as much of it as possible by dampingdevices.
7/31/2019 Economical Design of Earhquake Resistant Structure
19/26
Cont.. By incorporating a layer of discontinuity (such as a properly designed
elastomeric bearing) which has a low lateral stiffness as compared tothe structural elements above and below it, the natural period of thestructure with a fixed-base can be elongated substantially.
Increasing the natural period of the structure invariably results inincreased deformations. Such deformations need to be controlled sothat the resulting stiffness of the structure is appropriate to itsserviceability requirements.
Some devices incorporate features of both base isolation as well asenergy dissipation. Examples of such devices include high dampingrubber bearings (HDR) and lead rubber dampings (LRB) . It ishighlighted that usual elastomeric bearings designed in accordance
with IRC (1999) may not be suitable in this regard. Only standard devices having detailed experimental data of their
performance should be used
7/31/2019 Economical Design of Earhquake Resistant Structure
20/26
Base isolation and energy dissipation (two in one)
7/31/2019 Economical Design of Earhquake Resistant Structure
21/26
Energy sharing Sometimes it is advantageous that the seismic energyentering from the ground into the structure does not get
localized. Special devices exist which can avoid significantenergy accumulation and ensure its distribution to variousstructural elements.
Here, the idea is not to reduce the total seismic energyentering into the structure but to judiciously distribute itamongst all the designated resisting elements. Suchdevices go by the name of Shock Transmission Units(STUs).
As Structure A and Structure B move slowly relative to eachother, the fluid is able to migrate through narrow orificesfrom one side of the piston to the other. For rapidmovements (e.g., earthquakes) the transfer of fluid is notpossible thereby locking the piston to its cylinder. In suchcircumstances the device acts as a rigid link between
Structure A and Structure B.
7/31/2019 Economical Design of Earhquake Resistant Structure
22/26
Cont In bridge structures the inertial force from the
superstructure can be transmitted to designated sub-structures.
In bridge structures the inertial force from thesuperstructure can be transmitted to designated sub-structures.
Application of STUs to a 1.0 km long bridge with
expansion joints only at the abutments and centralpier is shown in Figure wherein the seismic forces aretransmitted to three piers in each of the two halves ofthe structure.
7/31/2019 Economical Design of Earhquake Resistant Structure
23/26
Shock Transmission Unit The principle
7/31/2019 Economical Design of Earhquake Resistant Structure
24/26
NHAIs Ganga Bridge at Allahabad showingapplication of STUs
7/31/2019 Economical Design of Earhquake Resistant Structure
25/26
CONCLUSION
There is scope after both passive control by prescribeddetailing procedures as well as active control byspecific devices for earthquake-resistant bridges. The
judicious use of these ideas can lead to economical andsafe bridge structures.
7/31/2019 Economical Design of Earhquake Resistant Structure
26/26
REFERENCES
ISET Journal of Earthquake Technology, Paper No. 453,Vol. 42, No. 1, March 2005, pp. 13-20 by MaheshTandon
AASHTO (1999). AASHTO LRFD Bridge DesignSpecifications, 1999 Interim, American Association ofState Highway and Transportation Officials,Washington, D.C.
BIS (1993). IS 13920-1993: Indian Standard Code ofPractice for Ductile Detailing of Reinforced ConcreteStructures Subjected to Seismic Forces, Bureau ofIndian Standards, New Delhi