Transcript
Page 1: DVS Handheld Programmer - Robert Pearson · The programmer will allow quick and easy adjustment; run-on time, purge and more. Real-time data can be uploaded from the programmer via

Handheld ProgrammerThe programmer will allow quick and easy adjustment; run-on time, purge and more. Real-time data can be uploaded from the programmer via the USB port to allow accurate monitoring of water efficiency.

Operation Via key pad and switchData processing Data download directly into Microsoft Excel via USB interfaceCharging Via USB interface for minimum of 8 hoursTime & Date Set via specific menu on controller

V2 Tap Menu Run time, Range, Anti-vandal time, Automatic purge, Purge runtime

Tap Menu Run time, Sensor range, Wave ON/OFF operation, Anti-vandal time

Shower Menu Run time, Sensor range, Wave ON/OFF operation, Anti-vandal time, Automatic purge, Purge run time, Lock outs

Urinal Menu Pre-flush wait, Pre-flush time, Main flush time, Sensor range, Anti-vandal time, Automatic purge, Purge run time

Bath Menu Run time, Sensor range, Wave ON/OFF operation, Anti-vandal time, Automatic purge, Purge run time, Lock outs

Auto Flush Valve Menu Range, User detect time, Dual detect time, Flush time(s), Walk away time, Automatic purge, Purge run time, Lock outs

Wave Flush Valve Menu Flush type, Flush time(s), Range, Automatic purge, Purge run time, Lock outs

Chlorinate Menu Chlorination time, Abort and reset

Technical Data:

Programming options: Adjustable settingsDVS Handheld Programmer

AC01-001

The programmer will allow quick and easy adjustment of settings including; run-on time, range, purge and more. Real time data can be uploaded from the programmer via the USB port to allow accurate monitoring of water efficiency.

Last Updated: 2015-10-30, Dart Valley Systems

PRODUCT NUMBER

AC01-001 DVS Handheld Programmer

TECHNICAL DATA

Operation Via key pad and switch

Data processing Data download directly into Microsoft Excel via USB interface

Charging Via USB interface for minimum of 8 hours

Time & Date Set via specific menu on controller

Programming options: Adjustable Settings:

V2 Tap Menu Run time, Range, Anti-vandal time, Automatic purge,

Purge runtime

Tap Menu Run time, Sensor range, Wave On / Off operation,

Anti vandal time

Shower Menu Run time, Sensor range, Wave On / Off operation,

Anti vandal time, Automatic purge Purge run time,

Lock outs

Urinal Menu Pre-Flush wait, Pre-Flush time, Main flush time,

Sensor range, Anti vandal time, Automatic purge,

Purge run time

Bath Menu Run time, Sensor range, Wave On / Off operation,

Anti vandal time, Automatic purge, Purge run time,

Lock outs

Auto Flush Valve Menu Range, User detect time, Dual detect time, Flush

time(s), Walk away time, Automatic purge,

Purge run time, Lock outs

Wave Flush Valve Menu Flush type, Flush time(s), Range, Automatic Purge,

Purge run time, Lock outs

Chlorinate Menu Chlorination time, Abort and reset

ALL DIMENSIONS IN MM

94

159

25

DVS Handheld Programmer

AC01-001

The programmer will allow quick and easy adjustment of settings including; run-on time, range, purge and more. Real time data can be uploaded from the programmer via the USB port to allow accurate monitoring of water efficiency.

Last Updated: 2015-10-30, Dart Valley Systems

PRODUCT NUMBER

AC01-001 DVS Handheld Programmer

TECHNICAL DATA

Operation Via key pad and switch

Data processing Data download directly into Microsoft Excel via USB interface

Charging Via USB interface for minimum of 8 hours

Time & Date Set via specific menu on controller

Programming options: Adjustable Settings:

V2 Tap Menu Run time, Range, Anti-vandal time, Automatic purge,

Purge runtime

Tap Menu Run time, Sensor range, Wave On / Off operation,

Anti vandal time

Shower Menu Run time, Sensor range, Wave On / Off operation,

Anti vandal time, Automatic purge Purge run time,

Lock outs

Urinal Menu Pre-Flush wait, Pre-Flush time, Main flush time,

Sensor range, Anti vandal time, Automatic purge,

Purge run time

Bath Menu Run time, Sensor range, Wave On / Off operation,

Anti vandal time, Automatic purge, Purge run time,

Lock outs

Auto Flush Valve Menu Range, User detect time, Dual detect time, Flush

time(s), Walk away time, Automatic purge,

Purge run time, Lock outs

Wave Flush Valve Menu Flush type, Flush time(s), Range, Automatic Purge,

Purge run time, Lock outs

Chlorinate Menu Chlorination time, Abort and reset

ALL DIMENSIONS IN MM

94

159

25

PTOJanuary 2018

Recommended