P i P e S y S t e m SSuitable for buildingS,
houSeS and civil conStruction PurPoSeS.
rainwaterdrainage SyStem
SySTEm fEaTurES & advantageS
22 rainwater System
aCCrEdiTaTiON& SPecification
4 4 Quality&Certification
5 Specifications&Standards
PiPES & fittingS detailS
7 7 rainwater Pipes
8 rainwater fittings
SOlvENT cement detailS
61 16 PalingSolventCementRange
17 Features,Advantages&Application
19 Specifications
iNSTallaTiON
02 20 InstallationGuidelines
21 faQs
abOuT uS
22 22 AboutPalingIndustries
22 AboutAliaxis
fEaTurES• Dimensionsandperformancemeettherequirementof
standards
• Highqualityoffinishwithsmoothinternalexternalsurface
• Provideslowcoefficientofflowfriction
• Formulatedtowithstandweatheringeffect
• Availableinseveralstiffnessclasstoaccommodatevariousinstallationsneeds
advaNTaGES• ChemicalResistance
• Non-Conductivity
• WeatherResistance
• NoRot,RustorCorrosion
• ToughandDurable
• LowMaintenance
aPPliCaTiONLead-freeRainwaterPipeSystemsaresuitableforbuildings,housesandcivilconstructionpurposes.
raiNwaTErSyStem
Product range
raiNwaTEr draiNaGE SySTEm /// fEaTurES & advaNTaGES
2
4
PiPeS fittingS
1. UnplasticizedPolyvinylChloride(PVC-U)PipesforRainwaterDischarge(LowandHighTemperature)withintheBuildingStructure.
2. UnplasticizedPolyvinylChloride(PVC-U)RainwaterPipesforabovegroundapplication
3. UnplasticizedPolyvinylChloride(PVC-U)HeavydutyRainwaterPipesforcastingandundergroundapplication
4. PalingEcotechPipes,madefrom
reprocessedmaterial,isleadfreeandearnshighonGreenBuildingIndex
1. UnplasticizedPolyvinylChloride(PVC-U)FittingsforRainwaterDischarge(LowandHighTemperature)withintheBuildingStructure.
qualiTy & CErTifiCaTiON
SySTEm CErTifiCaTiON
bSENdiN
Solvent cement
1. ColoursolvePolyvinylChloride(PVC)Solventcement
raiNwaTEr draiNaGE SySTEm /// aCCrEdiTaTiON
For updated copies of our certificates, please visit the Paling website www.paling.com.my
5
PiPESmOdEl NOm.
SiZESPECifiCaTiON
(mm)
NormalDuty 82,110 & 160 bS en 12200
MediumDuty 56, 110, 160, 200, 250 & 315 bS en 1329 / mS 1063
MediumDuty 82 bS 4514 / mS 1063
MediumHi-Duty/ClassC 200, 250 & 315 bS en 12200 / bS en 1329
HeavyDuty 110, 160, 200, 250 & 315 bS en 12200 / din 8061
fiTTiNGSmOdEl NOm.
SiZESPECifiCaTiON
(mm)87.5ºHeavyDutyBend 110, 160 & 200 bS en 1329/ mS 1063
SweptBend 56, 110, 160, 200, 250 & 315 bS en 1329 / mS 1063 / bS en 1401
SweptBend 82 bS 4514/ mS 1063
SweptBendwith Inspection Opening 56, 110, 160, 200, 250 & 315 bS en 1329/mS 1063/ bS en 1401
SweptBendwith Inspection Opening 82 bS 4514/ mS 1063
45ºBend with Inspection Opening 56,110 & 160 bS en 1329/mS 1063/ bS en 1401
45ºBendwith Inspection Opening 82 bS en 4514/ mS 1063
68ºBend 110, 160 & 200 bS en 1329 / mS 1063
SweptBranch 56, 110, 160, 200, 250 & 315 bS en 1329 / mS 1063/ bS en 1401
SweptBranch 82 bS 4514/ mS 1063
SweptBranchwith Inspection Opening 56, 110, 160, 200, 250 & 315 bS en 1329/ mS 1063/ bS en 1401
SweptBranchwith Inspection Opening 82 bS 4514/ mS 1063
SweptBranchwith Inspection Opening (L/R) 110 bS en 1329/ mS 1063
UnequalSweptBranch 160x110,200x160,250x200&315x250 bS en 1329/ mS 1063/ bS en 1401
UnequalSweptBranchwith Inspection Opening 160x110,200x160,250x200&315x250 bS en 1329/ mS 1063/ bS en 1401
45ºY-Branch 82 bS 4514/ mS 1063
45ºY-Branch 110, 160, 200, 250 & 315 bS en 1329/ mS 1063/ bS en 1401
Unequal45ºY-Branch 160x110,200x160,250x160&250x200 bS en 1329/ mS 1063/ bS en 1401
45ºY-Branchwith Inspection Opening 82 bS 4514/ mS 1063
45ºY-Branch with Inspection Opening 110 bS en 1329/ mS 1063
Unequal45ºY-Branchwith Inspection Opening 160x110 bS en 1329/ mS 1063
StraightCoupler 56, 110, 160, 200, 250 & 315 bS en 1329/ mS 1063/ bS en 1401
StraightCoupler 82 bS 4514/ mS 1063
PipeSleeve 56, 110, 160, 200, 250 & 315 bS en 1329/ mS 1063/ bS en 1401
PipeSleeve 82 bS 4514/ mS 1063
ExpansionCoupler 82 bS 4514/ mS 1063
ExpansionCoupler 110 & 160 bS en 1329/ mS 1063
SocketPlug with Screw on Cap 56, 110, 160, 200, 250 & 315 bS en 1329/ mS 1063/ bS en 1401
SocketPlug with Screw on Cap 82 bS 4514/ mS 1063
ConcentricReducer 82x56 bS 4514/ mS 1063
ConcentricReducer 110x56&160x110 bS en 1329/ mS 1063
LevelInvertReducer 110x82 bS en 1329/ mS 1063/ bS en 1401
LevelInvertReducer 200x110,200x160,250x200,315x200&315x250 mS 1063
Bush/SocketReducer 82x56&110x82 bS 4514/ mS 1063
Bush/SocketReducer 110x56,160x110&200x160 bS en 1329/ mS 1063
BossConnectorwith Bracket 110x82&160x82 bS 4514/ mS 1063
InspectionOpening&Frame 110x82&160x82 bS 4514/ mS 1063
BalconyOutlet 82, 110 & 160
HeavyDutyDomeGrating 110, 160, 200, 250 & 315
SPECifiCaTiONS /// raiNwaTEr draiNaGE SySTEm
6
raiNwaTEr PiPES
Paling rainwater Piping System has been developed to meet the need of construction industry for a reliable piping system for channelling rainwater from the roof to the drains. The system is suitable for all applications and types of building, including domestic, commercial and industrial.
AsthescopeofBSEN12200RainwaterGoods&Accessories
coversrainwaterpipesinnominalsizesfrom82mmto
110mmonly,additionalsizesandclassesofrainwaterpipes
havebeenincorporatedinthePalingRainwaterPiping
SystemtomeetdifferentrequirementsofBSEN1329-1,MS
1063andDIN8061.
TheNormalDutyPipeisintendedforexposedinstallationon
thebuildingthatdonotexceedfivestoreysinheight,such
asterracehousesorlow-riseshop-houses.TheMediumDuty
isintendedforexposedinstallationonbuildingexceeding
fivestoreyswhiletheHeavyDutyisdesignedwithhigher
ringstiffnessforuseinpipeworktobeencasedinreinforced
concrete(RC)columns.
D
L
e
raiNwaTEr draiNaGE SySTEm /// PiPES
7
NOrmal duTy raiNwaTEr PiPE-Recommendedforexposeinstallationforlowrise(5StoreyandBelow)
COdE NO. NOm.SiZE
(mm)
SPECifiCaTiON PiPEENd
OuTSidEdiamETEr d
(mm)
wall THiCKNESSe
(mm)
lENGTHl
(meter)
1220 082 58 nd 01 82 bS en12200/bS 4576 Pe 82.4-82.8 1.8-2.3 5.8
1220 110 58 nd 01 110 bS en12200/bS 4576 Pe 110.0-110.3 2.2-2.7 5.8
1220 160 58 nd 01 160 bS en12200/bS 4576 Pe 160.0-160.4 3.2-3.8 5.8
mEdium duTy raiNwaTEr PiPE-Recommendedforexposeinstallation(HighRise)
COdE NO. NOm.SiZE
(mm)
SPECifiCaTiON PiPEENd
OuTSidEdiamETEr d
(mm)
wall THiCKNESSe
(mm)
lENGTHl
(meter)
1220 056 58 md 01 56 bS en 12200/bS en 1329 Pe 55.8-56.1 3.0-3.5 5.8
1220 082 58 md 01 82 bS en 12200/bS en 1329 Pe 82.4-82.8 3.0-3.5 5.8
1220 110 58 md 01 110 bS en 12200/bS en 1329 Pe 110.0-110.3 3.2-3.8 5.8
1220 160 58 md 01 160 bS en 12200/bS en 1329 Pe 160.0-160.4 4.0-4.6 5.8
1220 200 58 md 01 200 bS en 12200/bS en 1329 Pe 200.0-200.5 4.9-5.6 5.8
1220 250 58 md 01 250 bS en 12200/bS en 1329 Pe 250.0-250.5 6.2-7.1 5.8
1220 315 58 md 01 315 bS en 12200/bS en 1329 Pe 315.0-315.6 7.7-8.7 5.8
mEdium Hi-duTy / ClaSS C raiNwaTEr PiPE-Recommendedforlowrisecasting&extremeexposeinstallation
COdE NO. NOm.SiZE
(mm)
SPECifiCaTiON PiPEENd
OuTSidEdiamETEr d
(mm)
wall THiCKNESSe
(mm)
lENGTHl
(meter)
1220 200 58 mhd 01 200 bS en 12200 Pe 200.0-200.5 7.8-8.8 5.8
1220 250 58 mhd 01 250 bS en 12200 Pe 250.0-250.5 9.7-11.2 5.8
1220 315 58 mhd 01 315 bS en 12200 Pe 315.0-315.6 11.5-13.3 5.8
HEavy duTy raiNwaTEr PiPE-Recommendedforcasting/undergroundcolumns
COdE NO. NOm.SiZE
(mm)
SPECifiCaTiON PiPEENd
OuTSidEdiamETEr d
(mm)
wall THiCKNESSe
(mm)
lENGTHl
(meter)
1220 110 58 hd 01 110 bSen12200/din 8061 Pe 110.0-110.3 6.0-6.8 5.8
1220 160 58 hd 01 160 bSen12200/din 8061 Pe 160.0-160.4 8.7-9.7 5.8
1220 200 58 hd 01 200 bSen12200/din 8061 Pe 200.0-200.5 10.8-12.0 5.8
1220 250 58 hd 01 250 bSen12200/din 8061 Pe 250.0-250.5 11.9-13.3 5.8
1220 315 58 hd 01 315 bSen12200/din 8061 Pe 315.0-315.6 15.2-17.5 5.8
ECOTECH raiNwaTEr PiPECOdE NO. NOm.
SiZEmEaN OuTSidE
diamETEr d (mm)PiPEENd
miN wallTHiCKNESS
lENGTHl
(mm) min max e (mm) (m)
1230 082 58 01 82 82.4 82.8 Pe 3.0 5.8
1230 110 58 01 110 110.0 110.3 Pe 3.2 5.8
1230 160 58 01 160 160.0 160.4 Pe 3.2 5.8
PiPES /// raiNwaTEr draiNaGE SySTEm
8
87.5° HEavy duTy bENd
45° uNSwEPT bENd
45° uNSwEPT bENd with Inspection Opening
COdE NO. NOm. SiZE
aNGlE dimENSiONS(mm)
(mm) Ѳ l1 a d
2210 056 01 56 45º 30 32 56
2210 082 01 82 45º 43 78 82
2210 110 01 110 45º 51 73 110
2210 160 01 160 45º 76 120 160
2210 200 01* 200 45º 94 118 200
2210 250 01* 250 45º 101 154 250
2210 315 01* 315 45º 116 192 315
*AvailableinMF&FF
COdE NO. NOm. SiZE
aNGlE dimENSiONS(mm)
(mm) Ѳ l1 a d
2203 056 01 56 45º 30 10 56
2203 082 01 82 45º 43 15 82
2203 110 01 110 45º 50 20 110
2203 160 01 160 45º 76 30 160
COdE NO. NOm.SiZE
aNGlE dimENSiONS(mm)
miN THiCKNESS
(mm) Ѳ l1 a d e(mm)
2201 110 hd 01 110 87.5º 51 73 110 5
2201 160 hd 01 160 87.5º 76 120 160 7
2201 200 hd 01 200 89º 94 18 200 9
L1 A
L1
A
D
e
L1
A
A
L1
D
L1A
A
L1
D
68° uNSwEPT bENdCOdE NO. NOm.
SiZEaNGlE dimENSiONS
(mm)
(mm) Ѳ l1 a d
2205 110 01 110 68º 52 56 110
2205 160 01 160 68º 80 74 160
2205 200 01 200 68º 100 96 200
220525001∆ 250 68º 120 81 250
220531501∆ 315 68º 220 81 315
∆ Fabricationitem
DL1
A
A
L1
D
raiNwaTEr draiNaGE SySTEm /// fiTTiNGS
9
SwEPT bENd with Inspection Opening
Tosolventweldtopipe,fittedwithinspectionopening
COdE NO. NOm. SiZE
aNGlE dimENSiONS(mm)
(mm) Ѳ l1 a d
2202 056 01 56 87.5º 30 32 56
2202 082 01 82 87.5º 43 78 82
2202 110 01* 110 87.5º 51 73 110
2202 160 01* 160 87.5º 76 120 160
2202 200 01* 200 89º 94 118 200
220225001∆ 250 89º 101 154 250
220231501∆ 315 89º 116 192 315
* AvailableinMF&FF
∆ Fabricationitem
L1 A
A
L1
D
SwEPT bENdTosolventweldtopipesorfittingsatbothends
COdE NO. NOm.SiZE
aNGlE dimENSiONS (mm)
(mm) Ѳ l1 a d
2201 056 01 56 87.5° 30 32 56
2201 082 01 82 87.5° 43 78 82
2201 110 01* 110 87.5° 51 73 110
2201 160 01* 160 87.5° 76 120 160
2201 200 01* 200 89° 94 118 200
2201 250 01 250 89° 101 154 250
2201 315 01 315 89° 116 192 315
* AvailableinMF&FF
L1 A
L1
A
D
SwEPT braNCH
L2 A
L
L1
D
CE
D
COdE NO. NOm. SiZE
aNGlE dimENSiONS(mm)
(mm) Ѳ l l1 a C E d
2211 056 01 56 87.5º 136 30 45 - - 56
2211 082 01 82 87.5º 206 45 76 - 43 82
2211 110 01 110 87.5º 250 50 75 - 56 110
2211 160 01 160 87.5º 360 77 145 82 65 160
2211 200 01 200 89º 381 86 206 - - 200
2211 250 01 250 89º 510 103 255 - - 250
221131501∆ 315 89º 616 116 301 - - 315
∆ Fabricationitem
fiTTiNGS /// raiNwaTEr draiNaGE SySTEm
SwEPT braNCH with Inspection Opening
COdE NO. NOm. SiZE
aNGlE dimENSiONS(mm)
(mm) Ѳ l l1 a C E d
2212 056 01 56 87.5º 136 30 45 - - 56
2212 082 01 82 87.5º 206 45 76 - 43 82
2212 110 01* 110 87.5º 250 50 75 - 56 110
2212 160 01 160 87.5º 360 77 145 82 65 160
221220001∆ 200 89º 381 86 206 - - 200
221225001∆ 250 89º 510 103 255 - - 250
221231501∆ 315 89º 616 116 301 - - 315
* AvailableinMF&FF
∆ Fabricationitem
L2 A
L
L1
D
CE
D
10
COdE NO. NOm.SiZE
aNGlE dimENSiONS (mm)
(mm) Ѳ l l1 a C E d
2212 110 le 01• 110 87.5º 250 52 80 56 76 110
2212 110 ri 01# 110 87.5º 250 52 80 56 76 110
• Branchwithleftopening# Branchwithrightopening
D
A
L1
L
EC
SwEPT braNCH with Inspection Opening (L/R)
uNEqual SwEPT braNCHCOdE NO. NOm.
SiZEaNGlE dimENSiONS
(mm)
(mm) Ѳ l l1 l2 a E d d1
2211 160110 01 160x110 87.5º 312 76 48 120 56 160 110
2211 200160 01 200x160 89º 381 86 77 206 - 200 160
2211 250200 01∆ 250x200 89º 510 103 86 255 - 250 200
2211 315250 01∆ 315x250 89º 616 116 103 301 - 315 250
∆ Fabricationitem
L2
L1
D1
D
L
A
E
uNEqual SwEPT braNCH with Inspection Opening
COdE NO. NOm.SiZE
aNGlE dimENSiONS (mm)
(mm) Ѳ l l1 l2 a E d d1
2212 160110 01 160x110 87.5º 312 76 48 120 56 160 110
2212 200160 01 200x160 89º 381 86 77 206 - 200 160
221225020001∆ 250x200 89º 510 103 86 255 - 250 200
221231525001∆ 315x250 89º 616 116 103 301 56 315 250
∆Fabricationitem
L2
L1
D1
D
L
E
A
45° y braNCHCOdE NO. NOm.
SiZEaNGlE dimENSiONS
(mm)
(mm) Ѳ l l1 w C E d
2213 082 01 82 45° 205 44 136 - 43 82
2213 110 01 110 45° 266 51 175 75 56 110D
D
L1 EC L
W
L1
raiNwaTEr draiNaGE SySTEm /// fiTTiNGS
11
uNEqual 45° y braNCHCOdE NO. NOm.
SiZEaNGlE dimENSiONS
(mm)
(mm) Ѳ l l1 l2 w C E d d1
2213 160110 01 160x110 45º 317 77 50 200 82 56 160 110D
D1
L2 E C
W
L
L1
45° y braNCHCOdE NO. NOm.
SiZEaNGlE dimENSiONS
(mm)
(mm) Ѳ l l1 b d
2213 160 01 160 45° 400 72 279 160
2213 200 01 200 45° 483 86 338 200
2213 250 01 250 45° 609 103 418 250
221331501∆ 315 45° 725 116 508 315
∆ Fabricationitem
D
D
L
L1
B
45° y braNCH with Inspection Opening
COdE NO. NOm.
SiZE
aNGlE dimENSiONS
(mm)
(mm) Ѳ l l1 w C E d
2214 082 01 82 45° 205 44 136 - 43 82
2214 110 01 110 45° 266 51 175 75 56 110D
D
L1
EC
W
L
fiTTiNGS /// raiNwaTEr draiNaGE SySTEm
uNEqual 45° y braNCHCOdE NO. NOm.
SiZE
aNGlE dimENSiONS
(mm)
(mm) Ѳ l l1 l2 b d d1
2213 200160 01 200x160 45° 430 86 74 304 200 160
2213 250160 01 250x160 45° 485 103 74 336 250 160
2213 250200 01 250x200 45° 539 103 86 370 250 200
D
D1
L
L1
B
L2
12
uNEqual 45° y braNCHwith Inspection Opening
COdE NO. NOm.SiZE
aNGlE dimENSiONS (mm)
(mm) Ѳ l l1 l2 w C E d d1
2214 160110 01 160x110 45° 317 77 50 200 82 56 160 110D
D1
L2
EC
W
L
L1
STraiGHT COuPlEr
PiPE SlEEvEForcastintoRCfloorslab/concretewallto
provideathroughsocketforpipes
COdE NO. NOm.SiZE
dimENSiONS (mm)
(mm) l l1 a d
2225 056 01 56 66 32 2 56
2225 082 01 82 97 47 3 82
2225 110 01 110 110 53 4 110
2225 160 01 160 167 82 4 160
2225 200 01 200 298 110 78 200
2225 250 01 250 370 130 110 250
2225 315 01 315 370 130 110 315
COdE NO. NOm.SiZE
dimENSiONS (mm)
(mm) l d d1
2225 056 01 56 112 92 76
2225 082 01 82 112 120 104
2225 110 01 110 112 147 131
2225 160 01 160 163 199 184
222520001∆ 200 205 245 225
222525001∆ 250 250 290 270
222531501∆ 315 300 360 340
∆ Fabricationitem
L
D1
D
D
L1
L1
AL
ExPaNSiON COuPlErToprovideonexpansionjointforpipeconnectionor
othermaterialspipeconnectionatbaseofstack
CombinationofSealRingAdaptorandStraightcoupler
COdE NO. NOm.SiZE
dimENSiONS (mm)
(mm) l l1 l2 d
2226 082 01 82 113 47 63 82
2226 110 01 110 133 53 75 110
2226 160 01 160 190 82 104 160L2
L1
L
D
raiNwaTEr draiNaGE SySTEm /// fiTTiNGS
13
SOCKET PluG with Screw on Cap
COdE NO. NOm.SiZE
dimENSiONS (mm)
(mm) l l1 d d1
2229 056 01 56 46 28 56 52
2229 082 l46 01 82 46 23 82 76
2229 082 l67 01 82 67 44 82 76
2229 110082 01* 110 80 50 103 76
2229 160 01 160 120 102 160 145
222920011001∆ 200 190 110 200 76
222925016001∆ 250 210 130 250 145
222931516001∆ 315 210 130 315 145
∆ Fabricationitem
* SocketPlugdimension‘D’isinternaldiameterof110mmØPipe
D
D1
L
L1
CONCENTriC rEduCErCOdE NO. NOm.
SiZEdimENSiONS
(mm)
(mm) l l1 l2 d d1 d2
2239 082056 01* 82x56 83 32 25 75 56 -
2239 110056 01 110x56 109 50 28 - 56 110
2239 160110 01# 160x110 145 75 49 160 110 -
* ConcentricReducerdimension‘D’istheinternaldiameterof82mmpipe# D’for160mmisspigot
D
D2
D1
L1
L
L2
lEvEl iNvErT rEduCErCOdE NO. NOm.
SiZEdimENSiONS
(mm)
(mm) l l1 l2 d d1
2244 110082 01 110x82 126 50 43 110 82
2244 200110 01 200x110 192 70 50 200 110
2244 200160 01 200x160 177 70 70 200 160
2244 250160 01 250x160 210 70 70 250 160
2244 250200 01 250x200 210 70 70 250 200
2244 315200 01 315x200 265 99 70 315 200
2244 315250 01 315x250 265 99 70 315 250
Disspigot
D1
L2
L1
D
L
fiTTiNGS /// raiNwaTEr draiNaGE SySTEm
buSH/ SOCKET rEduCErToallowforchangeinfittingssocketdiameter
COdE NO. NOm.SiZE
dimENSiONS (mm)
(mm) l l1 d d1
2236 082056 01 82x56 38 28 82 56
2236 110056 01 110x56 50 27 110 56
2236 110082 01 110x82 50 37 110 82
2236 160110 01 160x110 71 48 160 110
2236 200160 01 200x160 85 94 200 160
2236 250110 01 250x110 120 48 250 110
2236 250160 01 250x160 120 58 250 160
2236315110MD01∆ 315x110 165 48 315 110
2236315160MD01∆ 315x160 165 58 315 160
2236315200MD01∆ 315x200 165 106 315 200
2236315250MD01∆ 315x250 165 120 315 250
∆ Fabricationitem
D
D1
L1L
14
A
DDr
bOSS CONNECTOr wiTH braCKET
bOSS CONNECTOr wiTH braCKET
COdE NO. NOm.SiZE
dimENSiONS (mm)
(mm) dr d a
2243 110056 01 110x56 110 56 30
2243 160082 01 160x82 160 82 45
Dr Nominaldiameterpipe
D Diameterofinletpipe
A Socketdepth
COdE NO. NOm.SiZE
dimENSiONS (mm)
(mm) dr d a
2243 082056 01 82x56 82 56 31
2243 110082 01 110x82 110 82 45
Dr Nominaldiameterpipe
D Diameterofinletpipe
A Socketdepth
iNSPECTiON OPENiNG & framE
COdE NO. NOm.SiZE
dimENSiONS (mm)
(mm) l a b
2238 082056 01 82x56 92 56.5 47
2238 110056 01 110x56 122 56.5 47
2238 110082 01 110x82 122 90 67
2238 160082 01 160x82 175 90 71A
B
L
balCONy OuTlET GraTiNG
COdE NO. NOm.SiZE
dimENSiONS(mm)
(mm) d3 l
2265 080 01 82 119 199
2265 110 01 110 148 205
2265 150 01 160 198 237
D3
L
raiNwaTEr draiNaGE SySTEm /// fiTTiNGS
A
DDr
15
HEavy duTy dOmE GraTiNG
COdE NO. NOm.
SiZE
dimENSiONS
(mm)
(mm) l H1 H2
2264 110 hd 01 110 210 110 64
2264 160 hd 01 160 270 130 88
2264 200 hd 01 200 305 130 90
2264250HD01∆ 250 300 130 90
2264315HD01∆ 315 350 130 90
∆ Fabricationitem
L
H1
H2
COdE NO. NOm.
SiZE
dimENSiONS
(mm)
(mm) l l1 l2 a b d d1
2258 110046 01 110x43 162 85 71 32 118 43 38
flOOr Gully wiTH TraPFloorGullycomescompletewithwatertrap,extension
gratingcollarandgratingtogetherwithspan-in-cover,
outletmayberoddedbyremovinggrating.
PPgrating&Collar
A
L1D1
B
DL2
L
LD4
L1
D
D1
COdE NO. NOm.
SiZE
dimENSiONS
(mm)
(mm) l l1 d d1 d2-d3-d4
2260 110 01 110x82 174 220 110 82 56
TOP rEmOvablE TraPPEd flOOr GullyIntegrallymouldedbossadaptorwith40mm(D3)&50mm
(D2)sockettoacceptwastepipeorotherfittings.
COdE NO. NOm.
SiZE
dimENSiONS
(mm)
(mm) l C
2254 110082 01 110x82 73 110
A-82mm Seatson82mmshortlengthpipesolvent
weldedtoConcentricReducer
B-110mm Seatson110mmshortlengthpipesolvent
weldedtoFloorGully
GraTiNGCanbeseatedinto82mmor110mmdrainagepipes
forfloorwells.
C
L
AB
LA
BB1
A1
COdE NO. NOm.
SiZE
dimENSiONS
(mm)
(mm) l a a1 b b1
2255 110 01 110x14 118 110 110 33 14
ExTENSiON GraTiNG COllarTobeusedasacollarforgrating.
fiTTiNGS /// raiNwaTEr draiNaGE SySTEm
COdE NO. dESCriPTiON GmS TiN/CarTON
60500 70P PalingClearsolvefastdry 500 20
60100 70 PalingClearsolvefastdry 100 60
60500 10 PalingColoursolveslowdry
(Blue)
500 20
60500 12 PalingColoursolvefastdry
(Green)
500 20
SOlvENT CEmENT
raiNwaTEr draiNaGE SySTEm /// SOlvENT CEmENT
16
fEaTurES• PVCSolventCementFastDry–forpipesandfittings
≤80mm
• PVCSolventCementSlowDry–forpipesandfittings ≥80mm
• Moderatesolventodour
• ComplieswithMS628orBS4346.SPANlisted
advaNTaGES• ColourCo-PolymerforEasierApplicationand
Inspection
• EasytoUse
• PremiumQuality
• FastandSlowDryingSolventavailableforStrongBonding
aPPliCaTiONPalingSolventCementisformulatedforPVCpipesusedforrainwaterandraingutterapplications.
SOlvENTcement
Product range
SOlvENT CEmENT /// raiNwaTEr draiNaGE SySTEm
17
18
Solid Content: 24%Consistency property: 1,000 cpsquality: Tough & resilientSolid consist of: mEK & CyCColour: GreenStandard: mS628 Part ii Section 2.2
- HighlysolublefastdryPVC-USolventcement.
- SuitableforjoiningallPVC-Upipesfrom15mm-75mm
diameter.
- Whenapplied,itwillinstantlydissolveandblendwiththe
pipetoproduceafilm(wall)of0.4mmthick,sothatthe
fittinggapwillbestrongandstable.
STraiNiNG TimE
Pipes with diameters 15mm 10 seconds
Pipes with diameters 25mm to 32mm 8 seconds
Pipes with diameters 50mm 6 seconds
Pipes with diameters 75mm 4 seconds
PaliNG COlOurSOlvE faST dry
PaliNG COlOurSOlvE SlOw dry
Solid Content: 24%Consistency property: 1,000 cpsquality: Tough & resilientSolid consist of: mEK, CyC & THfColour: blueStandard: mS628 Part ii Section 2.2
- HighlysolubleslowdryPVC-USolventcement.
- SuitableforjoiningallPVC-Upipesfrom75mm-200mm
diameter.
- Whenapplied,itwillinstantlydissolveandblendwiththe
pipetoproduceafilm(wall)of0.4mmthick,sothatthe
fittinggapwillbestrongandstable.
STraiNiNG TimE
Pipes with diameters 25mm 20 seconds
Pipes with diameters 32mm to 50mm 16 seconds
Pipes with diameters 75mm to 100mm 12 seconds
Pipes with diameters 150mm 8 seconds
Pipes with diameters 200mm 4 seconds
aTTENTiON:
1. Temperaturebelow15°C(50°F)willextendthestrainingperiodforapproximately5minutesforeachtypeof
pipe.
2. AlltheabovesolventcementisnotapplicabletothosePVC-Upipeorfittingwhicharemadeofpartlyrecycled
material.
3. Afterassembly,thepipemustbetightlyheldinplaceandshallonlybereleasedafterrecommendedstraining
timeasstipulated.Ifreleaseprematurely,thepipetobefittedwillspringapart.
PaCKiNG CTN. SiZE
500g.(withbrush)x20Tinsperctn. 508mmx220mmx225mm
raiNwaTEr draiNaGE SySTEm /// SPECifiCaTiONS
19
NOmiNal SiZE Of PiPE Or fiTTiNG
amOuNT Of SOlvENT CEmENT rEquirEd PEr JOiNT
NO OfPOSSiblE JOiNTS
(mm) (g) 100 g 500 g15 1.3 76 383
20 2.0 55 250
25 2.5 40 200
32 3.2 30 156
40 5.0 20 100
50 7.2 13 69
80 12.0 8 41
100 15.5 6 32
155 26.0 2 19
200 49.0 1 10
SOlvENT CEmENT rEquirEmENT fOr PvC-u PiPES & fiTTiNGS
rECOmmENdaTiONS ON bruSH: PrESSurE TEST:
PHySiCal aNd CHEmiCal PrOPErTiES
A: Pipeswithdiameter25mmandbelow-usebrushas
accompaniedandaffixedtocan
B: Pipeswithdiameter32mmto50mm-use1"brush
C: Pipeswithdiameter75mmto200mm-use2"brush
flash point: 15°C
flammable mixture (uN No. 1133)Thissolventcementmaterialwilligniteatambient
temperatures.Colourlessvapoursmaytravelconsiderable
distancetoignitionsourcesandcauseflashfiresor
explosions.
Hazard IdentificationMaycauseeyesandskinirritation,burnsordermatitis.
TEST PrESSurE dryiNG TimE
ColdWater(20°C) Below12kg/cm2(171psi) After1hour
HotWater(60°C) Below12kg/cm2(171psi) After2hours
StorageStoreinwell-ventilatedarea.Keepawayfromheat,sparks
andflame.
Safety advice- Keepoutofreachofchildren.
- Keepawayfromsourcesofignition-NoSmoking.
- Avoidcontactwitheyes.
- Incaseoffire,usechemicalpowder,foamorcarbon
dioxide.
SPECifiCaTiONS /// raiNwaTEr draiNaGE SySTEm
20
-3-aPPly THE SOlvENT
CEmENTApplyadhesiveevenlytobothsidestobematedusingabrushingstrokeparalleltooralongthepipeaxis.Itisrecommendedthata1”brushbeusedtoapplythesolventcement
can or tin well before using to ensure homogeneity.
-4-maKE THE JOiNT
Insertpipestraightintothefittingasdeeplyintothefittingsocketaspossiblewithouttwistingandholdinplacefirmly
andsteadilyforatleasttensecondsforFastDryandtwentysecondsforSlowDry.
Removeexcesssolventcementwithasoftcloth.Asmallclosedadhesiveringshouldbeclearlyvisibleattheendofthefittingtosignalthatthesufficientadhesivehasbeen
applied.
-5-ClEaN THE ExCESS SOlvENT
CEmENTWhenmakingmultiplejointsonapipingsystem,
anundisturbedrestperiodofatleastfiveminutesisrequiredbeforesecondbondcanbecarriedout.Thisistoavoidstresstothefirstjoint,whichmayweakenits
adhesion.
wait 24 hours before testing or use
-2-dEGrEaSE THE SPiGOT
aNd SOCKETMarktheinsertiondepthtothepipespigottoavoidexcessiveapplicationandprovidescontrolastowhetherpipehasbeenadequatelyinserted
intothefitting.
Cleanpartstobefusedwithprimingfluidtoensurethatdirtandpossibleslipandreleaseagentsareremovedforoptimalresults.ScrapeoffanydiscolouredpipelayerduetoUV-radiationorproperbondingcannot
beachieved.
forpipeswithdiametersbetween32to50mmand2”brushforpipeswithdiametersabove50mm.Jointmustbemadewithin2minutesofstarting
application.
-1-CuT & dEburr
Wherenecessary,cutpipetolengthatrightangletoitsaxistomaximizesurfaceforbonding.Useofamitreboxandfinetoothsawis
recommended.
Cutsurfaceneedtobedeburredandchamferedtoaslightbeveltosimplifycentredinsertionanduniformadhesivedistribution
between parts.
aSSEmbly PiPES wiTH SOlvENT CEmENT JOiNTS
raiNwaTEr draiNaGE SySTEm /// iNSTallaTiON GuidEliNES
frEquENTlyASKEDQUESTIONS
wHaT arE THE qualiTiES Of raiNwaTEr SySTEmS THaT uSE PvC?PVCisrecommendedforrainwatersystems,asitisaversatilematerialofhighquality.Itisresistanttoweather,chemicalsandUVradiation.Flexibleandresistanttomechanicalshock,PVCpipesandgutterscanbecolouredtoyourspecification.Long-lastingandvirtuallymaintenancefree,theyprovidethemostcost-effectiveoptionforyourrainwatersystem.
iS PaliNG ablE TO PrOvidE a full raNGE PiPE SySTEm SOluTiONS?Weprovideproductsrangesupto315mmtosuitthemarketsneeds.
CaN i uSE PvC-u PiPES fOr CHEmiCal fluidS?PVCisnon-corrosivebynature.Itisunaffectedbychemical,electrolyticandiconiccorrosion.PVCpipesarehighlyresistanttochemicalreaction,sotheyarecapableofresistingtheeffectsofvariouskindsofacids,alkalis,oxidizingagents,oilsanddomesticeffluents.
CaN PaliNG PvC-u PiPES bE CaST iN CONCrETE?Wehavevariouspipesstiffnessfordifferentapplications.NormalDuty/MediumDutyarenotusuallyusedforcasting.HeavyDutyisthebestpipesforcastingapplicationsasitisdesignedwithhigherstiffness.
dOES a raiNwaTEr PiPiNG SySTEm laST lONG?PalingRainwaterPipingSystemsareexpectedtolastover50yearswheninnormalservice.Pipesandfittingsareresistanttorustandchemicalreactions,andremainfreeofscaleformation.
faqs /// raiNwaTEr draiNaGE SySTEm
21
Aliaxisispresentinmorethan40countries.TheGrouphasmorethan100manufacturingandcommercialentitiesandemploysover14,600people.
TheethosoftheGroupallowslocalandglobalknowledgeoftheindustry,regulationsandbuildingpracticestocombineandprovideconsistentlyexcellentcustomerservicetospecifiers,consultants,contractors,installersandothers.
THE aliaxiS GrOuP iS a lEadiNG GlObal maNufaCTurEr aNd diSTribuTOr Of Primary PlaSTiC fluid HaNdliNG SySTEmS uSEd iN rESidENTial aNd COmmErCial CONSTruCTiON.
THE aliaxiS GrOuPabOuT
iN aSia
malaysia:KualaLumpur
vietnam:HoChiMinh
india:Bangalore,Mumbai&Goa
Singapore
China:Beijing,Shanghai&Guangzhou
abOuT
PaliNG iNduSTriES SdN. bHd. waS ESTabliSHEd iN 1971 TO PrOduCE uPvC PiPES & fiTTiNGS iN malaySia. OvEr THE yEarS iT HaS ExPaNdEd iTS raNGE TO OTHEr SaNiTary PrOduCTS aNd SySTEmS liKE PlaSTiC CiSTErNS aNd OTHEr aCCESSOriES.
PaliNG iNduSTriES
Thesesystemsaresuitableforvariousapplicationsandbuildingtypes,includingdomestic,commercial,industrialandcivilconstructionprojects.Palingproductsareaccuratelydesignedtoconsistentlyexceedtheperformanceaspectsspecifiedunderwidelyrecognizedstandards.
AlongwithISO9001certificationandvariousapprovalsbySIRIMandIKRAM,PalingproductsareaccreditedbyNSF,anauthorityinwaterindustrystandards.
Palingproductsaremanufacturedunderaneffectivesystemofinspection,testing,supervisionandcontrol.
raiNwaTEr draiNaGE SySTEm /// abOuT uS
22
disclaimer
ThisbrochurehasbeencompiledbyPalingIndustriesSdnBhd(“thecompany”)topromotebetterunderstandingofthetechnicalaspectsoftheCompany’s
productstoassistusersinobtainingfromthemthebestpossibleperformance.Thebrochureissuppliedsubjecttoacknowledgmentofthefollowing
conditions:
i) ThebrochureisprotectedbyCopyrightandmaynotbecopiedorreproducedinanyformorbyanymeansinwholeorinpartwithoutpriorconsentin
writingbytheCompany.
ii) Productspecifications,usagedataandadvisoryinformationmaychangefromtimetotimewithadvancesinresearchandfieldexperience.The
Companyreservestherighttomakesuchchangesatanytimewithoutnotice.
iii) CorrectusageoftheCompany’sproductsinvolveengineeringjudgementswhichcannotbeproperlymadewithoutfullknowledgeofalltheconditions
pertainingtoeachspecificinstallation.TheCompanyexpresslydisclaimsallandanyliabilitytoanypersondonebyanysuchpersoninreliancewhether
wholeorpartialuponthewholeoranypartofthecontentsofthisbrochure.
iv) Nooffertotrade,noranyconditionsoftrading,areexpressedorimpliedbytheissueorcontentofthisbrochure.
v) NothinghereinshalloverridetheCompany’sconditionsofSale,whichmaybeobtainedfromtheRegisteredOfficeoranySalesOfficeoftheCompany.
vi) ThisbrochureisandshallremainthepropertyoftheCompany,andshallsurrenderedondemandtotheCompany.
P r e S S u r eP i P i n g S y S t e m
P i P e S y S t e m SSuitable for buildingS,
houSeS and civil conStruction PurPoSeS.
P i P e S y S t e m SSuitable for buildingS,
houSeS and civil conStruction PurPoSeS.
hydrotechtm
mS3MU L T I - L AY E R P V C - U
undergrounddrainage &Sewer
SyStem
P i P e S y S t e m SSuitable for buildingS,
houSeS and civil conStruction PurPoSeS.
P i P e S y S t e m S
Suitable for buildingS and houSeS
EleganceraingutterS
P i P e S y S t e m SSuitable for buildingS,
houSeS and civil conStruction PurPoSeS.
Soil,waSte&vent SyStem
P i P e S y S t e m SSuitable for civil
conStruction PurPoSeS and buildingS.
r a i n wat e rSyStem & gyROJOINT
Lot12,JalanPerusahaan4,68100BatuCaves,SelangorDarulEhsan,malaysia.
T :603-61898333(General) 603-61896389(Sales)
f :603-61883810
distributed by :
PaliNG iNduSTriES SdN bHd (11039 v)
w w w . p a l i n g . c o m . m y