ABSTRACT
Most of the car accidents that happen in the streets are alcohol-related crashes, the
driver is drunk. The researchers are developing a system which can detect if the driver
is drunk or not. The Driver Alcohol Detection Systems for Safety will measure the
blood content of the driver in two possible ways, through a driver’s breath or through
the skin. This is done by the use of sophisticated touched-based sensors that would
possibly be placed in the door locks or steering wheel.
The researchers conducted its first public demonstration of the alcohol-detection
system that could measure if the driver has reached the blood alcohol limit of .08. If
the system detected the alcohol content of the driver is above the limit, the vehicle
will not start. In a test demonstration, let’s test a man who drinks 3 1/2 ounce glasses
of vodka and orange juice about 30 minutes apart, eating some cheese and crackers in
between to imitate a critical social setting. After that, using the touched-based and
breath-based prototypes they found out that a man has an alcohol content of .06 thus
he can start the car. Though the system is 99.9% reliable, some of the groups are
questioning the .08 limit since the blood alcohol content rises during a trip, also to
some factors such how recently the driver is drunk and how much he/she ate. This
system is still needs a long process though they predict that this is the option for
future cars.
Future technologies are expected to be much faster and less intrusive, requiring no
active involvement from the driver. Essentially, the technology will be invisible to
drivers, so that sober drivers wouldn't be inconvenienced.
In our alcohol detection system the ignition of the fuel is regulated by a sensor circuit.
The sensor circuit is used to detect whether alcohol was consumed by the driver
recently. Our design also consists of a body perspiration rate sensor which is used to
check whether alcohol is consumed while driving.
0
INTRODUCTION
Drunken drivers have been let unchecked in the society. Though there are laws to
punish drunken drivers they cannot be fully utilized as police cannot stand on every
road corner to check each and every car driver whether he has drink or not. This leads
to severe accidents killing people on the spot or physically impairing them. So there is
a necessity to develop an efficient alcohol detection system.
The Automotive Coalition for Traffic Safety and the National Highway Traffic Safety
Administration have entered into a cooperative research agreement to explore the
feasibility, the potential benefits of, and the public policy challenges associated with a
more widespread use of in-vehicle technology to prevent alcohol-impaired driving.
“Almost 9,000 road traffic deaths could be prevented every year if alcohol detection
devices were used in all vehicles.”
Aftermarket ignition interlocks have been used successfully among convicted drunk
drivers to significantly reduce the incidence of impaired driving. However,
deployment of the current technology on a more widespread basis as a preventative
measure is not likely to occur because drivers are required to provide a breath sample
each and every time before starting the vehicle. To be acceptable for use among the
general public, including those who do not drink and drive, alcohol detection
technologies must be far less intrusive – they must not impede sober drivers from
starting their vehicles. They would need to be capable of rapidly and accurately
determining and measuring alcohol in the blood. They would also need to be small,
reliable, durable, repeatable, maintenance free, and relatively inexpensive.
Two approaches have been identified that have considerable promise in measuring driver BAC non-invasively:
1) Tissue Spectrometry, a touch-based approach allowing estimation of alcohol in human tissue,
2) Distant Spectrometry that will allow assessment of alcohol concentration in the subject’s exhaled breath.
1
WORKING PRINCIPLE OF ALCOHOL DETECTORS
DISTANT SPECTROMETRY
In breath-based approach, we are using an external cavity quantum cascade
technology. These sensors are designed to measure Ethanol emanating from the driver
by simultaneously measuring the concentration of Alcohol and Carbon dioxide in the
cabin air near the driver. The tricky part is placing sensors to ensure that breath
samples are taken from the driver, not other passengers.
DESIGN OF ALCOHOL SENSOR
The MQ-3 is an alcohol gas sensor that is available from Sparkfun, Seed Studio and
others. It’s easy to use and has sparked the imagination of anyone who has dreamed of
building their own breathalyzer device for measuring the amount of alcohol in the
human body.
For typical alcohol detection we are using MQ-3 gas
sensor which is highly sensitive to alcohol.
The features of MQ-3 gas/Alcohol sensor are:
1. High sensitive to alcohol and small sensitive to
benzene.
2. Fast response and high sensitivity.
3. Stable and long life.
4. Simple drive circuit.
2
CONNECTING AND TESTING
The gas sensor canister plugs into the socket on the front of the module. The gas
sensors are essentially resistive devices and are not polarized, so there is no need to be
concerned about plugging it in “backwards.” It will work in either orientation.
The 4-pin SIP header on the Gas Sensor Module makes it easy to connect to a
breadboard or SIP socket. The four connections are defined in the table below.
Connection to a 5V microcontroller, such as the BASIC Stamp® module, would be
pretty straight forward and require two I/O pins; one input for detecting the alarm
signal and the other an output for controlling the internal heater.
For a 3.3V microcontroller such as the PropellerTM chip, a 3.9 kΩ (10 kΩ could be
used) resistor would be required from the ALR output to the Propeller chip input pin.
For the Propeller to control the heater switch input (HSW) you would need an NPN
switching transistor, such as a 2N3904 and a 1 kΩ resistor.
The schematic for this connection is shown below.
Fig.1 schematic connections for alcohol sensor
3
THEORY OF OPERATION
These gas sensor modules use gas sensors from Hanwei Electronics. When their
internal heating elements are activated, these gas sensors respond to their specific gas
by reducing their resistance in proportion to the amount of that gas present in the air
exposed to the internal element. On the gas sensor modules this is part of a voltage
divider formed by the internal element of each gas sensor and potentiometer R3 (Set
Point). The output of this voltage divider is fed into the non-inverting inputs of the
two op-amps on the LT1013 dual op-amp IC. Op-amp A is configured as a buffer
with unity gain and is used to provide a non-loaded test point for the signal voltage at
TP1 (+) and TP2 (-). The signal voltage is also being fed into op-amp B which is
configured as a comparator that gets its reference voltage at the inverting input from
potentiometer R4 (Trip Level) and is also available at TP3 (+) and TP4 (-).
The output of op-amp B goes out to the ALR pin through a 1 kΩ resistor providing a
TTL-compatible signal to a microcontroller. This output also connects to a red LED
on the gas sensor modules. The zero gas span adjustment is set via potentiometer R3.
As mentioned above R3 allows you to change the span/range of the voltage divider
formed by the gas sensor and R3 which is the bottom leg of the divider, electrically
speaking. Adjusting R3 to lower values will make the gas sensor less sensitive but
more stable. Avoid setting R3 below 200 ohms as at this point you will be close to
shorting the output to ground. Setting R3 to higher values will make the gas sensor
more responsive, but without a minimum load it will become unstable after a certain
point. The trip level adjustment is set via potentiometer R4.
This is just a simple voltage divider that lets you set the voltage from 0V to 5V. This
voltage is compared to the voltage coming from the gas sensor/R3 divider. When the
voltage from the gas sensor is higher than the voltage set by potentiometer R4 the red
LED will light and the ALR output will be high (5 V).
LAYOUT AND CONFIGURATION OF MQ-3 SENSOR
Structure and configuration of gas sensor is shown as Fig. 1 (Configuration A or B),
sensor composed by micro AL2O3 ceramic tube, Tin Dioxide (SnO2) sensitive layer,
measuring electrode and heater are fixed into a crust made by plastic and stainless
4
steel net. The heater provides necessary work conditions for work of sensitive
components. The enveloped MQ-3 has 6 pin, 4 of them are used to fetch signals, and
other 2 are used for providing heating current.
Fig.2 Layout of Gas Sensor
SENSITVITY ADJUSTMENT
5
Resistance value of MQ-3 is difference to various kinds and various concentration
gases. So, when using these components, sensitivity adjustment is very necessary. We
recommend that you calibrate the detector for 0.4mg/L ( approximately 200ppm ) of
Alcohol concentration in air and use value of Load resistance that( RL) about 10 KΩ.
When accurately measuring, the proper alarm point for the gas detector should be
determined after considering the temperature and humidity influence.
CO2 SENSOR
The CO2 (Carbon Dioxide) Gas Sensor Module is designed to allow a microcontroller
to determine when a preset Carbon Dioxide gas level has been reached or exceeded.
Interfacing with the sensor module is done through a 4-pin SIP header and requires
two I/O pins from the host microcontroller. The sensor module is mainly intended to
provide a means of comparing carbon dioxide sources and being able to set an alarm
limit when the source becomes excessive.
Fig.4 Schematic of CO2 sensor.
6
WIRING THE SENSOR
Sensing material
It is well known that chemisorbed oxygen (Oad−) on SnO2 plays an important role in
the sensitivity behavior of the gas sensor. The reactivity of Oad− is so high that it easily
reacts with the reducing gas in the ambient, which in turn injects electrons into the
oxide, thereby increasing the conductivity. However, Weisz limitation dictates that
the concentration of Oad− has to be less than 1%, at which surface acceptor level
becomes equal to the Fermi level of SnO2 by the band bending of the depletion layer.
7
The change of Oad− concentration less than 1% due to the catalytic reaction with
reducing gas cannot make more than 100 times difference in the bulk conductivity.
Therefore, the action of inter-granular barrier is proposed as an explanation.
According to this model, conductivity is expressed as G=G° exp(−qVS/kT), where VS
is the barrier height at inter-granular contacts, which is proportional to [Oad−]2.
As a result, the sensitivity of the sensing material has intimate connection with the
nature of the contact, which is determined by the history of the material preparation.
In practice, all the contacts in the path of percolating channel between two electrodes
take part in the resistance of the sensor to play a role in the sensitivity. These series of
contacts are very sensitive to the condition of heat treatment of the sensing material
and the material parameter itself.
Generally, voltage-dividing circuit is used to measure the concentration of gas. Output
voltage is expressed as
Sensor Calibration Challenges
So, I simply need to use the sensor to determine how many mg/L of alcohol there is in
my breath, right? The bad news is that it is very difficult to know how much alcohol is
in your breath in terms of mg/L! The poorly written MQ-3 datasheet says to calibrate
the sensor by exposing it to a known alcohol gas of 0.4mg/L. From there, you can
determine gas alcohol content in terms of mg/L.
But how do I create an air environment with 0.4mg/L alcohol? I could evaporate
0.4mg of ethanol (that’s the type of alcohol we’re talking about here) in a liter of air,
but how do I measure out exactly 0.4mg of pure ethanol? I don’t have a source of pure
ethanol. I could buy 151 proof Everclear grain alcohol but then would need to account
for the different density when measuring this tiny quantity. And there’s the additional
complexity in that evaporating aqueous ethanol will alter the humidity, and the sensor
8
readings are sensitive to humidity! This is getting complicated. If were really
motivated, I would drive to Wisconsin where I could buy 190 proof (95%) Everclear.
Last time I drove to Wisconsin was to buy illegal fireworks, and it seems that my only
reason for visiting Wisconsin is to purchase contraband and smuggle it back into
Minnesota. But I digress…the bottom line is that calibration according to the MQ-3
datasheet is hard.
Another calibration approach would be to use my breath as a “known” concentration
of ethanol after drinking a known quantity of alcoholic beverages. I could drink the
right amount of alcohol to give a 0.4mg/L concentraion in my breath and measure the
resistance to get my calibration baseline. But this presents problems, too! The sensor
calibration depends on 0.4mg/L concentration in “clean air”. What is “clean air”? I
think it means air that is devoid of other contaminating gases that affect the sensor,
and assumes 21% oxygen concentration and 65% humidity at room temperature.
Those conditions are not going to be true in my breath!
My head is spinning, and I haven’t even started drinking yet. In short, I don’t know
how to create the right conditions for accurate calibration without a laboratory. Any
ideas welcome.
THEORY OF OPERATION
The CO2 gas sensor module uses a gas sensor (MG811) from Hanwei Electronics.
When the internal heating element is activated, this gas sensor responds to CO2 gas
by generating a small voltage in proportion to the amount of CO2 gas present in the
air exposed to the internal element. The sensor is a high impedance device and
requires a buffer/amplifier to measure the output. The output from the buffer/amplifier
(op-amp) is then sent to the inverting input of another op-amp in the same package
(LMC6035) which is configured as a comparator. A voltage divider formed by R3 is
used to provide a reference voltage. The output of this voltage divider is fed into the
non-inverting inputs of the second op-amp on the LMC6035 dual op-amp IC. The
buffered output of the sensor can be measured for the signal voltage at TP1 (+) and
TP2 (-). The reference voltage is available at TP3 (+) and TP4 (-).
9
Fig.5 Schematic of CO2 Sensor
The output of op-amp B goes out to the ALR pin through a 1 kΩ resistor providing a
TTL-compatible signal to a microcontroller. The trip level adjustment is set via
potentiometer R3. This is just a simple voltage divider that lets you set the voltage
from 0V to 3.3V. This voltage is compared to the voltage coming from the gas sensor
buffer/opamp. When the voltage from the gas sensor is lower than the voltage set by
potentiometer R3 the red LED will light and the ALR output will be high (3.3 V). The
voltage from the sensor actually drops as CO2 increases. The section below describes
how to configure these gas sensor modules to detect gas with minimal calibration.
SCHEMANTIC OF ALCOHOL DETECTION SYSTEM
The schematic of alcohol system consists of an IC, gas sensor, carbon dioxide sensor
and a power supply.
All the connections are made as shown in the schematic figure. The power supply is
attached to all the three components, i.e. sensors and IC.
10
When the power supply is ON all the components get activated and the sensors give
the required inputs to the Microcontroller. The microcontroller then processes the
inputs given by the sensors and sends the required output to the ignition circuit.
If the sensors detect the alcohol content, then the microcontroller sends the signal to
kill the power to the ignition circuit.
Fig. 6 Schematic of Alcohol detection system
11
DESIGN OF LOGIC CIRCUIT
The various possibilities arising in the above circuit are
1. The driver is not drunk.
2. The driver is drunk.
3. The driver is not present.
Consider the change of color of salt as logic 1 and no color change as logic 0.
Consider the presence of CO2 as logic 1 and the absence of CO2 as logic 0.
TRUTH TABLE FOR THE CIRCUIT
CO2 Sensor
Alcohol Sensor
Output to
Relay
1 0 1
1 1 0
0 0 0
• So if CO2 is detected and Alcohol is absent then power supply from battery reaches the spark plug.
• If both Alcohol and CO2 is detected then the supply from the battery will not reach the spark plug.
• If both are undetected then also there will be no supply to the spark plug.
The gate diagram can be given as follows
A (alcohol) C (output)
B (CO2)
12
OPERATION OF ALCOHOL DETECTING SYSTEM
1. The Driver enters the car and places the ignition key.
2. When the key is turned a voice prompts the driver to prepare to give a breath
test. The driver has over 60 seconds to provide a deep lung breath sample.
3. As soon as the ignition key is placed, the alcohol detecting system gets
activated and the alcohol sensor placed near the driver cabin takes the readings
of Alcohol and CO2.
4. The breath sample is analyzed in 8 - 10 seconds.
5. Allows 6-8 second resamples as needed.
6. After test completion, a voice either prompts the driver to start the car or lets
him/her know it will not start (a lockout condition).
7. To discourage someone else from providing the original breath sample,
"random rolling retests" are given at intervals after starting.
8. If a retest is failed, a voice instructs the driver to pull over and shut off the
car. If this instruction is ignored, the horn sounds and the lights blink until the
car is shut off.
9. If the system detected the alcohol content of the driver is above the limit, the
system kills the power supply to the ignition circuit and the vehicle will not
start.
Thus the alcohol detecting system prevents the driver from driving the car if he is
drunk.
13
ADVANTAGES
1. Helps in reducing road accidents caused by drunk driving.
2. Eradicates the use of police officers to check the ongoing traffic.
3. Cost of installation is very cheap.
DISADVANTAGES
1. If the driver opens his window, due to the clean airflow from outside the
alcohol system may not function properly.
2. If the system kills the power supply to the ignition circuit when he is running
on a freeway, it would be a greater threat to oncoming vehicles.
14
TISSUE SPECTROMETRY
In Tissue Spectrometry, we use a touch-based prototype using near-infrared (NIR)
absorption spectroscopy to measure alcohol in skin tissue. It is designed to work by
shining NIR light on the user's skin. The light scatters several millimeters through the
user's skin before returning to the skin's surface, where it's collected by an optical
touch pad and analyzed to determine tissue alcohol concentration.
The fact used in this process is that after consumption of alcohol the pulse rate
decreases which increases the body heat and the perspiration rate. But the perspiration
rate varies significantly for different persons. So after initial testing the perspiration
rate of the person is recorded using perspiration sensors. The perspiration sensors
consist of very sensitive miniature infrared which gets deflected by the blood
perspiration. The number of pulses per minute is recorded by a perspiration counter
circuit. The initial reading is taken as reference and periodic checks are made by the
sensors, if there is significant increase is perspiration rate then the car stops.
These touch sensors can be placed in the steering wheel or in the transmission knob.
These sensors continuously monitor the blood alcohol levels in the body by taking the
samples from the perspiration produced by the body.
Fig. 7 Checking the blood alcohol level using Tissue Spectroscopy
15
On-board ILS ethyl alcohol sensors based on intracavity laser spectroscopy (ILS) are
provided lor detecting the presence ol ethyl alcohol vapors in a vehicle. The sensor
comprises:
(a) a laser comprising a gain medium having two opposed lacets within a laser
resonator and lunctioning as an intracavity spectroscopic device having a first end and
a second end, the first end operatively associated with a partially reflecting (i.e.,
partially transmitting) surface;
(b) a reflective or dispersive optical element (e.g., a mirror or a diffraction grating)
operatively associated with the second end to define a broadband wavelength laser
resonator between the optical element and the first end and to thereby define an
external cavity region between at least one facet of the gain medium and either the
first end or the second end or both ends;
(c) The external cavity region being exposed to air in the cabin of the vehicle to
enable any ethyl alcohol molecules to enter thereinto;
(d) A detector spaced from the first end;
(e) Appropriate electronics for measuring and analyzing the detector signal;
(f) a housing for containing at least the laser, the partially reflecting surface, and the
optical element, the housing being configured to prevent escape of stray radiation into
the cab and to permit air from the cab to continuously circulate through the external
cavity region for analysis; and
(g) means for driving the laser (e.g., electrical or optical). A method is provided for
measuring concentration of ethyl alcohol vapors in a vehicle employing the on-board
sensor. The method comprises:
(1) sensing any ethyl alcohol vapors in the cab by the on-board sensor; and
(2) providing a signal indicative of presence of any alcohol vapors.
16
UNITS OF MEASUREMENT
There are several different units in use around the world for defining blood alcohol
concentration. Each is defined as either a mass of alcohol per volume of blood or a
mass of alcohol per mass of blood (never a volume per volume). 1 milliliter of blood
is approximately equivalent to 1.06 grams of blood. Because of this, units by volume
are similar but not identical to units by mass. In the U.S. the concentration unit 1%
w/v (percent weight/volume, equivalent to 10g/l or 1g per 100ml) is in use. This is not
to be confused with the amount of alcohol measured on the breath, as with a
breathalyzer. The amount of alcohol measured on the breath is generally accepted to
be proportional to the amount of alcohol present in the blood at a rate of 1:2100.
Therefore, a breathalyzer measurement of 0.10 mg/L of breath alcohol converts to
0.021 g/210L of breath alcohol, or 0.021 g/dL of blood alcohol (the units of the BAC
in the United States).
Unit Dimensions Equivalent to Used in
1 percent (%) BAC by volume
1/100 g/mL = 1 cg/mL
9.43 mg/g, 217.4 mmol/L
United States, Australia, Canada, Spain
1 permille (‰) BAC by volume
1/1000 g/mL = 1 mg/mL
0.943 mg/g, 21.7 mmol/L
Netherlands, Lithuania, Latvia, Poland, Germany, Switzerland, Austria, Romania, Turkey
1 basis point (‱) BAC by volume
1/10,000 g/mL = 100 μg/mL
94.3 ppm, 2.17 mmol/L
Britain
1 permille (‰) BAC by mass
1/1000 g/g = 1 mg/g
1.06 mg/mL, 23 mmol/L
Finland, Norway, Sweden, Denmark
1 part per million (ppm)
1/1,000,000 g/g = 1 μg/g
1.06 μg/mL, 23 μmol/L
17
EFFECTS OF ALCOHOL
Progressive effects of alcohol
BAC (% by vol.)
Behavior Impairment
0.010–0.029 Average individual appears
normal
Subtle effects that can be
detected with special
tests
0.030–0.059
Mild euphoria
Sense of well-being
Relaxation
Joyousness
Talkativeness
Decreased inhibition
Concentration
0.06–0.09
Blunted feelings
Disinhibition
Extroversion
Reasoning
Depth perception
Peripheral vision
Glare recovery
0.10–0.19
Over-expression
Emotional swings
Angriness or sadness
Boisterousness
Super human feeling
Decreased libido
Reflexes
Reaction time
Gross motor control
Staggering
Slurred speech
0.20–0.29
Stupor
Loss of understanding
Impaired sensations
Severe motor impairment
Loss of consciousness
Memory
0.30–0.39
Severe CNS depression
Unconsciousness
Death is possible
Bladder function
Breathing
Heart rate
≥0.40 General lack of behavior Breathing
18
Unconsciousness
Death Heart rate
STANDARD DRINKING CHART
Standard drink chart (US)
AlcoholAmount
(ml)Amount
(fl oz)Serving
sizeAlcohol (% by
vol.)Alcohol
80 proof liquor
44 1.5 One shot 400.6 US fl oz (18 ml)
Table wine 148 5 One glass 120.6 US fl oz (18 ml)
Beer 355 12 One can 50.6 US fl oz (18 ml)
BLOOD ALCOHOL PERCENTAGE
MaleFemale
Approximate blood alcohol percentage (by vol.) One drink has 0.5 US fl oz (15 ml) alcohol by volume
Drinks
Body weight
40 kg 45 kg 55 kg 64 kg 73 kg 82 kg 91 kg 100 kg 109 kg
90 lb 100 lb 120 lb 140 lb 160 lb 180 lb 200 lb 220 lb 240 lb
1–
0.050.040.05
0.030.04
0.030.03
0.020.03
0.020.03
0.020.02
0.020.02
0.020.02
19
2–
0.100.080.09
0.060.08
0.050.07
0.050.06
0.040.05
0.040.05
0.030.04
0.030.04
3–
0.150.110.14
0.090.11
0.080.10
0.070.09
0.060.08
0.060.07
0.050.06
0.050.06
4–
0.200.150.18
0.120.15
0.110.13
0.090.11
0.080.10
0.080.09
0.070.08
0.060.08
5–
0.250.190.23
0.160.19
0.130.16
0.120.14
0.110.13
0.090.11
0.090.10
0.080.09
6–
0.300.230.27
0.190.23
0.160.19
0.140.17
0.130.15
0.110.14
0.100.12
0.090.11
7–
0.350.260.32
0.220.27
0.190.23
0.160.20
0.150.18
0.130.16
0.120.14
0.110.13
8–
0.400.300.36
0.250.30
0.210.26
0.190.23
0.170.20
0.150.18
0.140.17
0.130.15
9–
0.450.340.41
0.280.34
0.240.29
0.210.26
0.190.23
0.170.20
0.150.19
0.140.17
10–
0.510.380.45
0.310.38
0.270.32
0.230.28
0.210.25
0.190.23
0.170.21
0.160.19
20
RESULTS
Program to configure the microcontroller
----------------------------------------------------------------------------------
library IEEE;
use IEEE.STD_LOGIC_1164.ALL;
use IEEE.STD_LOGIC_ARITH.ALL;
use IEEE.STD_LOGIC_UNSIGNED.ALL;
---- Uncomment the following library declaration if instantiating
---- any Xilinx primitives in this code.
--library UNISIM;
--use UNISIM.VComponents.all;
entity alcoholdetector is
Port ( clk : in STD_LOGIC;
x : in STD_LOGIC;
y : in STD_LOGIC;
z : out STD_LOGIC);
end alcoholdetector;
architecture Behavioral of alcoholdetector is
begin
if x ='0' then
z <= 0;
else
if y = '0' then
z <= 1;
else
z <= 0;
21
end if;
end Behavioral;
Code for interfacing Alcohol Gas Sensor MQ-3 with Microcontroller
const int analogPin = 0; // the pin that the potentiometer is attached toconst int ledCount = 10; // the number of LEDs in the bar graph
int ledPins[] = { 11,10,9,8,7,6,5,4,3,2 // Here we have the number of LEDs to use in the BarGraph };
void setup() {
for (int thisLed = 0; thisLed < ledCount; thisLed++) { pinMode(ledPins[thisLed], OUTPUT); }}
void loop() { //This is the code to light up LED's int sensorReading = analogRead(analogPin);
int ledLevel = map(sensorReading, 500, 1023, 0, ledCount);
for (int thisLed = 0; thisLed < ledCount; thisLed++) {
if (thisLed < ledLevel) { digitalWrite(ledPins[thisLed], HIGH); }
else { digitalWrite(ledPins[thisLed], LOW); } }}
22
OUTPUT Wave forms
TEST ASSUMPTIONS
Blood alcohol tests assume the individual being tested is average in various ways. For
example, on average the ratio of blood alcohol content to breath alcohol content
(the partition ratio) is 2100 to 1. In other words, there are 2100 parts of alcohol in the
blood for every part in the breath. However, the actual ratio in any given individual
can vary from 1300:1 to 3100:1, or even more widely. This ratio varies not only from
person to person, but within one person from moment to moment. Thus a person with
a true blood alcohol level of .08 but a partition ratio of 1700:1 at the time of testing
would have a .10 reading on a Breathalyzer calibrated for the average 2100:1 ratio.
A similar assumption is made in urinalysis. When urine is analyzed for alcohol, the
assumption is that there are 1.3 parts of alcohol in the urine for every 1 part in the
blood, even though the actual ratio can vary greatly.
Breath alcohol testing further assumes that the test is post-absorptive—that is, that the
absorption of alcohol in the subject's body is complete. If the subject is still actively
absorbing alcohol, their body has not reached a state of equilibrium where the
concentration of alcohol is uniform throughout the body. Most forensic alcohol
experts reject test results during this period as the amounts of alcohol in the breath
will not accurately reflect a true concentration in the blood.
24
CONCLUSION
A design has been developed for alcohol detection in cars/vehicles which can
efficiently check the alcohol levels of the driver. By implementing this design
accidents caused by the drunk drivers can be controlled to a greater extent.
Future technologies are expected to be much faster and less intrusive, requiring no
active involvement from the driver. Essentially, the technology will be invisible to
drivers, so that sober drivers wouldn't be inconvenienced.
Government must enforce laws to install alcohol detectors in the cars and must
regulate all the car companies to preinstall such mechanisms in their cars.
25
REFERENCES
Alcohol Consumption Impairs Detection of Performance Errors in
Mediofrontal Cortex
Alcohol detection device
JW Rugis… - US Patent 4,607,719, 1986 - Google Patents
Development of the Alcohol Use Disorders Identification Test (AUDIT):
WHO Collaborative Project on Early Detection of Persons with Harmful
Alcohol Consumption-II
http://www.hwsensor.com
www.parallax.com
www.dadss.org
www.sciencedaily.com
www.insideline.com
26