V E N T I N G D E S I G N S O L U T I O N S
EXHAUSTO Inc.1200 Northmeadow Pkwy.Suite 180Roswell, GA 30076USA
P: 770.587.3238F: 770.587.4731T: [email protected]
Chimney Automation Systems
Multistory Fireplace Exhaust Systems
Mechanical Dryer Venting Systems
Modulating Building Exhaust Systems
Designing Thoughtful Green Performance - On-Demand Venting and Exhaust Systems
23 51 13/EXHBuyLine 8599
Energy usage in mixed use buildings varies depending on the type of building and the time of day. For example, hotels use a lot of hot water in the mornings, but very little throughout the day. Schools are heated during the day, but not at night. Sports arenas may have minimal activity for several days and then high usage over a weekend. Instead of keeping these systems operating at full capacity during non-peak hours, “venting on-demand” allows the exhaust system to precisely adjust to changing energy demands.
Designed for use in many different types of buildings
Hotels/Resorts Offi cesHospitals
Apartments/Condominiums
Schools/Colleges
Sports Arenas
Controlled airfl ow
Systems that require exhaust or ventilation, such as boilers, dryers, kitchens and bathroom and fi replaces, rarely operate 24 hours a day. However, most exhaust systems are designed to operate at maximum exhaust, regardless of the energy demand. For large, multi-use buildings, this constant operation can represent a signifi cant expense and ineffi cient equipment operation.EXHAUSTO’s “venting on-demand” technology, also known as demand control ventilation, is one of the most effi cient ways to save energy and optimize ventilation performance. The system operates 24 hours a day at a pre-set low speed. When the fi replace or dryer or kitchen is in use, the system automatically adjusts the exhaust rate to meet current demands, ensuring optimal performance at the lowest possible energy levels.
Venting On-Demand offers a better venting solution for boilers, dryers, kitchens & bathrooms and fi replaces
Most ventilation systems run at full speed regardless of the demand. “Venting on-demand” adjusts to meet the needs of the system.
3 6 9 12 3 6 9 12
100
75
50
25
% Use
TimeAM PM
Max. Fan Capacity
3 6 9 12 3 6 9 12
100
75
50
25
% Use
TimeAM PM
Max. Fan Capacity
EXHAUSTO has actively promoted low-energy installations and energy savings for decades – long before it became “in”. For years EXHAUSTO has been involved in the European legislation processes and has been a member of United States Green Building Council (USGBC) since 2005. All EXHAUSTO’s systems and products helps to qualify for the Energy & Atmosphere credits. Unlike most manufacturers we didn’t have to come up with ”new” GREEN solutions – we have made them for decades!
Green building saves money, energy and the environment
Custom Designed
Many ventilation systems feature rigid construction that make them diffi cult to fi t into a building without signifi cant work-around. EXHAUSTO’s venting system is designed to accommodate the building – not the other way around – making designs that were once impossible now possible.
With high-quality components and superior technology, EXHAUSTO is de-signed to withstand the rigorous demands of a high-density building. Because we don’t compromise when it comes to selecting components, once it’s installed it requires only routine maintenance to keep it running around the clock.
Reliable Space Saving
In vertical subdivisions, space is at a premium so it’s important for a ventilation system to be both compact and powerful. EXHAUSTO meets both requirements with a system that‘s designed to save space without sacrifi cing performance.
Designing with Sustainable Advantages
Economical
Not only does an EXHAUSTO ventilation systems save money by lowering energy costs, the effi ciency of the system makes it easier to install, reducing labor costs.
Aesthetically Pleasing
Today’s buildings are designed to be both functional and attractive, which means making the venting system less obtrusive. Because an EXHAUSTO system takes up less space and requires fewer ducts, it allows architects and engineers to keep the vents out of sight – both inside and outside the building.
EnvironmentallySustainable
EXHAUSTO helps to create more sustainable buildings by reducing the overall ventilation demand and by optimizing energy savings in other areas of the building. In addition, our compo-nents are made from recycled materials to minimize the impact on the environment, and they can be recycled at the end of their service life.
V E N T I N G D E S I G N S O L U T I O N S
23 51 13/EXHBuyLine 8599
EBC 30 controller
XTP Sensor
Clothes Dryers
This is a unique fi replace and exhaust system for common venting of multiple ISOKERN gas-fi red fi replaces in residential, multistory buildings. The system is composed of multiple ISOKERN B-Vent fi replaces and one or more EXHAUSTO RSV fans, an EBC30 control and an automated actuator/balancing damper system and features On-Demand control. Each fi replace is connected to a common vent and vented by the RSV fan. This is a very economical solution that allow installation of high quality fi replace at a reasonable price while saving
space inside a building. Can be connected to a BMS system via an optional
BACnet module.
Multistory Fireplace & Exhaust System – MFES
Mechanical Dryer Venting System – MDVSThe MDVS is used to extract lint-laden air from Type 1 or Type 2 clothes dryers. It is suitable for dryers in multistory buildings whether installed in each dwelling or in a central laundry facility. It features On-Demand control that maintains a precise exhaust condition for the dryers by constantly adjusting the exhaust rate to meet current needs.The concept assure that dryers are never over- or under-drafted and optimal dryer times are achieved. Can provide savings up to 70% compared to fi xed speed fan installations. A truly ‘green’ solution that saves energy and space inside a building. Can be connected to a BMS system via an optional BACnet module.
V E N T I N G D E S I G N S O L U T I O N S
EBC 30 control monitor
Fireplace controller
XTP sensor
ADM motorized damper
Modulating hi-temp exhaust fan
BESB hi-effi ciency fan
Modulating Building Exhaust System – MBESThis is a unique exhaust system for common venting of multiple kitchen hoods or bathrooms in residential, multistory buildings. It features On-Demand control that maintains a precise exhaust condition for the kitchens and bathrooms by constantly adjusting the exhaust rate to meet current needs. Can provide savings up to 70% compared to fi xed fan speed installations. A truly ‘green’ solution that saves energy and takes up much less space inside a building. Can be connected to a BMS system via an optional BACnet module.
V E N T I N G D E S I G N S O L U T I O N S
RSV hi-temp exhaust fan
Boilers
Kitchen hoods
EBC30 controller
XTP sensor
XTP sensor
EBC 30 controller
BESB or EFH exhaust fan
Chimney Automation System – CASVThe CASV is used to monitor and control the draft for boilers, water heaters and other heating appliances. It is suitable for condensing or non-condensing heating appliances. It features On-Demand control that maintains a precise exhaust condition for the heaters by constantly adjusting the exhaust rate to meet current needs. The concept assure that heaters are never over- or under-drafted and optimal effi ciency and emissions are achieved. Can provide savings up to 20-30% compared to alternative systems. A truly ‘green’ solution that saves energy. And architecturally pleasing as it can hide chimney terminations and take up much less space inside a
building. Can be connected to a BMS system via an optional BACnet module.
p eas g as t ca de c ey te at o s a d ta e upbuilding. Can be con
via an optional B
23 51 13/EXHBuyLine 8599
EXHAUSTO Support ServiceEXHAUSTO solutions are so much more than just products and systems. We provide pre-sale analysis, system design and implementation recommendations. During this process we use state-of-the-art design software, developed by EXHAUSTO, which enables us to design any system with great accuracy and speed. Systems designed by EXHAUSTO come complete with AutoCAD installation instructions and wiring diagrams for the specifi c job. They are not generic diagrams but drawings showing where com-ponents are installed and exactly how they are wired together
so potential problems in the fi eld are resolved before they occur. A customized installation and wiring package is part of the delivery. EXHAUSTO offers telephone engineering and installation support. All designs are stored electronically, so our engineers and technicians know exactly what a system looks like and what it includes. As EXHAUSTO usually designs the entire venting system, we also take full responsibility for its operation. This is part of EXHAUSTO’s “PerformanceGuarantee”.
EBCFull featured exhaust control that monitors and controls exhaust fl ow by modulating the connected fan. Plug-and play design. BACnet compatible.
BESBPowerful low-energy, variable speed, direct-drive fan with cast aluminum impeller. Insulated and balanced for ultra-quiet operation. Spark resistant design.
MDFOver-draft damper used in boiler venting systems with excessive draft. Is operated via and EBC30 control.
EXHAUSTO products
EXHAUSTO Inc.1200 Northmeadow Pkwy.Suite 180Roswell, GA 30076USA
P: 770.587.3238F: 770.587.4731T: [email protected]
V E N T I N G D E S I G N S O L U T I O N S
The range of products and servicesEXHAUSTO combines quality components, superior technology and experienced personnel to deliver a system that is economical, environ-mentally sustainable, aesthetically pleasing and reliable. The following are some of the key components of the EXHAUSTO systems.
FanCalc allows EXHAUSTO’s experienced engineers to design complete venting systems fast, accurate and effi ciently, while providing engineers with sizing reports, code violation warnings as well as design alternatives.
EXHAUSTO has venting design capabi lities that not many fan or venting manufac-turer can match. In addition to creating venting system designs, FanCalc checks for code violations. It calculates and checks for proper vent type application, operating temperatures, pressure losses in each venting component, risk of con-densation and provides system specifi c wiring diagrams.
EXHAUSTO FanCalcdesign service
RSVLow energy, variable speed, direct-drive fan with verti-cal exhaust in a compact design. Cast aluminum impeller and housing. Tamper, corrosion and spark resistant design with class H motor.
MEC18Simple and easy-to-operate exhaust control reduces power consumption of the fan and saves energy by supplying constant pressure in ducts for dryers, kitchens and bathrooms.
EFHLow energy, variable speed, direct-drive fan in compact design with cast aluminum impeller. Made in cast aluminum and is corrosion and tamper resistant. Spark resistant design.