For illustrative purposes only
TECHNICAL DATASHEET
CRICKET - P 105
Strong points1- Industrial diesel engine in genset version with certificate oforigin2- Industrial brushless alternator with AVR3- Steel baseframe with fuel tank and with sensor4- Soundproof canopy in galvanised, power coated sheet steel5- Soundproofing material made of high attenuation polyesterfibre6- Internal exhaust silencer with insulated manifold7- Electrical panel mounted on board the unit with digitalcontrol device installed in metal box8- Compact for easy handling and use9- Test report, manuals and electrical drawings supplied10- World wide after sales service and technical supportFurther details on the technical data sheet
PerformanceContinuous power (PRP) 114.5 (kVA)
Continuous power (PRP) 91.6 (kW)
Stand-by power (LTP) 125.5 (kVA)
Stand-by power (LTP) 100.4 (kW)
Power factor 0.8
VoltageFrequency (Hz) 60 Hz
Voltage (V) 208 V
Dimensions* and noise levelWidth 1120 mm
Length 2650 mm
Height 1380 mm
Weight 1400 kg
Sound pressure 7 m. 75 dBA
Data referencesStandard reference conditions temperature 25°C, altitude 100m asl, relative humidity 30%,atmospheric pressure 100 kPa (1 bar), power factor 0.8 lag, balanced load - nondistortional. Fuel consumption is nominal and refers to specific weight 0,850kg/l. Soundpower values refer to free field conditions: the installation site may influence the values.Dimensions, weights and other specifications contained in the technical data sheet andrelated attachments are nominal, subject to tolerances and refer to the model withstandard equipment; any optional and additional equipment/accessories can modify weight,dimensions, performance.P.R.P. Prime Power-Continuous power at variable load: The power that a genset cansupply in continuous service at a variable load for an unlimited number of hours per yearwhile respecting the maintenance intervals established in the environmental conditionsstated by the Manufacturer. according to ISO8528-1. The average power supplied over timeand any applicable overload must be less than the percentages stated by the Manufacturer.L.T.P. Limited-time running power-Limited power: The maximum power that a gensetcan supply for a limited time respecting the maintenance intervals established in theenvironmental conditions stated by the Manufacturer according to ISO 8528-1.The numberof hours per year is stated by the Manufacturer. Overload is not permitted.
EngineEngine brand PERKINS
Engine model 1104C-44TAG2
Cylinders 4
Speed 1800 r.p.m.
Cubic capacity 4.40 l
Air intake Turbocharged
Standard voltage 12 Vdc
Optional voltage Vdc
Sae 3-11½
BMEP
Cooling
1618 kPa
Water
Engine powerFlywheel P.R.P. Power 106.8 kW
Flywheel Stand-by Power 116.9 kW
Fuel consumptionFuel Cons. at 100% (L.T.P.) 29.7 l/h
Fuel Cons. at 100% (P.R.P) 26.9 l/h
Fuel Cons. at 75% (P.R.P.) 20.2 l/h
Fuel Cons. at 50% (P.R.P.) 14.1 l/h
Fuel Cons. at 25% (P.R.P.) 0.0 l/h
Speed regulationElectronic regulator Standard
Precision class G3
Engine dimensions and liquidsOil quantity 8.0 l
Engine Antifreeze capacity 7.0 l
Radiator standard IM50
The data contained in this document is nominal and refers to the standard equipped model and is not binding. Visa S.p.A. reserves theright to revise the information without notice per our policy of continuous product development and improvement.
VISA S.p.A. - ITALY- CERTIFIED ISO 9001 - 2008 & ISO 14001/2004 - www.visa.it
*Dimensions: Measurements referred to the complete unit.Minor components might be disassembled to optimize shipping.
60Hz 208V
TECHNICAL DATASHEET
CRICKET - P 105
Heat from engineHeat from radiator 57.7 kW
Heat from exhaust 89.8 kW
Heat from radiation 8.5 kW
Exhaust dataExhaust temperature 517 °C
Cooling air flow 225.60 m³/min
Combustion air flow 7.75 m³/min
Exhaust gas flow 18.40 m³/min
EmissionsTA Luft Not available
TA Luft/2 Not available
EPA Not available
Stage Not available
AlternatorAlternator brand STAMFORD
Alternator model UCI274D
P.R.P. Power 131.3 kVA
L.T.P. Power 142.5 kVA
Alternator wiringsConnection Series star
Phases 3 phases + neutral
Winding 12 terminalsWinding 311
Terminal Number 12 nr.
Alternator protectionIP Protection 23
Voltage regulatorElectronic regulator SX460
Precision 1.5 ± %
BaseframeModel CRICKET CK30
Standard tank 145 l
Optional tank
Oversized tank*
Canopy & SilencerCanopy model CRICKET CK30
Silencer model
Silencer outlet diameter
The data contained in this document is nominal and refers to the standard equipped model and is not binding. Visa S.p.A. reserves theright to revise the information without notice per our policy of continuous product development and improvement.
VISA S.p.A. - ITALY- CERTIFIED ISO 9001 - 2008 & ISO 14001/2004 - www.visa.itPowered by TCPDF (www.tcpdf.org)
Available control panels
Optional control panelsATS is a new line of changeover switch panelsdeveloped and manufactured by Visa S.P.A. inaccordance with CEI EN 61439-2 (constructionstandard). Specifically used for generatingsets, the changeover switch panel allows thechangeover between mains/genset orgenset/genset. The main part of the panelcontains two interlocking contactors or amotorised circuit breaker. All of the parts areinstalled inside a sturdy powder-coated metalbox (RAL7035) and equipped with a lock toclose the access door.
The DSE4520 is a compact Auto Mains (Utility) Failure Control Module that has been developed to provide an outstanding range of features within a compact enclosure. Monitoring an extensive number of engine parameters, the module will display warning, shutdown and engine status information on the LCD screen.
MSR/a 50
mm
Not available
Not available
60Hz 208V